HomeMy WebLinkAboutSD-95-0000 - Decision - 0002 0004 Market StreetFINDINGS OF FACT & DECISION
STATE OF VERMONT
COUNTY OF CHITTENDEN
CITY OF SOUTH BURLINGTON
Re: Findings of Fact, application of Century Partners for a
planned unit development consisting of 87,457 square feet of
general office and shopping center use in four (4) buildings, 100
Dorset Street and 2 Corporate Way.
On the 8th day of August, 1995, the South Burlington Planning
Commission approved the request of Century Partners for preliminary
plat approval under Section 203 of the South Burlington Subdivision
Regulations based on the following findings:
1. This project consists of expanding a shopping center by: 1)
constructing a two (2) story 35,000 square foot building (building
"A"), 2) constructing a one (1) story 8,350 square foot building
(building "B"), 3) constructing a one (1) story 4,200 square foot
building (building "C"), 4) constructing a two (2) story 168 space
parking garage, 5) constructing a 300 square foot addition to the
main building, 6) converting 600 square feet of unused space to
retail use, and 7) razing an 8736 square foot 603 seat theater
building. These improvements will result in a total of 87,457
square feet of gross leasable area in four (4) buildings. The
sketch plan was reviewed on 4/25/95.
2. This property located at 100 Dorset Street and 2 Corporate Way
lies within the Cl and CD1 Districts. It is bounded on the north
by a commercial building used for personal service and retail, on
the east by the Ramada Inn and undeveloped property, on the south
by the Anchorage Motor Inn and Corporate Way, and on the west by
Dorset Street.
3. Access/circulation: Access is via a 30 foot curb cut on Dorset
Street opposite the Chittenden Bank access drive at a signalized
intersection. There are also two (2) secondary access drives to
the Greer property to the north. The applicant has previously
recorded a legal agreement which requires the applicant to provide
an access easement to the Greer property when the Greer's provide
the applicant with a similar access easement. A 24 foot wide curb
cut is proposed on Corporate Way. An access to the Ramada Inn
property is also shown.
Circulation is adequate.
4. Coverage/setbacks: Cl District: Building coverage was not
submitted. This information should be submitted for final plat.
Overall coverage will be reduced from 87% to 84.3% (maximum allowed
is 70%). Front yard coverage along Dorset Street has not been
submitted. This information should be submitted for final plat.
5. CD1 District:
is 43.8% (maximum
Overall coverage
Building coverage including the parking garage
allowed is 90% if a parking garage is proposed).
is 67.5% (maximum allowed is 90%).
6. Building "A" will not meet the 50 foot front yard setback
requirement. Building is proposed to be 20 feet from the Dorset
Street r.o.w. The Planning Commission, under Section 12.406(b) of
the zoning regulations, may modify setback requirements.
7. Building "B" and "C" and the 300 square foot addition will meet
the setback requirements. The main building at 100 Dorset Street
does not meet the rear setback requirement and is therefore a
noncomplying structure subject to Section 26.002 of the zoning
regulations.
B. Landscaping: The minimum landscaping requirement, based on
building costs, is $36,525 which is being met. Proposed plantings
include Linden, Ash, Hydrangea, Lilac, Juniper, Crabapple, Spruce,
Balsam Fir and Spirea.
9. The street trees along Corporate Way should be at least 3 -
3.5" caliper as recommended in the City Center Streetscape
Guidelines Handbook. The planting schedule should be revised to
reflect this minimum size.
10. Parking: This project requires a total of 430 spaces and a
total of 420 spaces are being provided including 10 handicapped
spaces. Parking requirements are based on office standards for the
office use and the shopping center standards for the remaining
development. The Planning Commission agreed to this at sketch plan
review. The parking facilities include a two (2) story parking
garage containing 160 spaces to be built in two (2) phases. Phase
1 will include 85 spaces and phase 2 will include 75 spaces.
11. The easterly most row of parking on 2 Corporate Way is located
within the 80 foot building envelope for the proposed Mary Street
extension. This is not permitted.
12. Bike racks are being provided as required under Section
26.253(b) of the zoning regulations.
13. Based on the loss of the 18 spaces mentioned above, this
development will have a parking shortfall of 28 spaces or 6.5%.
14. F.A.R. The floor area ratio within the CD1 District is 0.07
(maximum allowed is 0.8).
15. Traffic: The applicant submitted a traffic impact analysis.
The analysis concludes that the additional traffic generated will
not change the level of service (LOS) for the study intersections
(Dorset Street intersections with Williston Road, the driveway at
100 Dorset Street, and Corporate Way/University Mall).
Pa
The study intersections will maintain an LOS of "C" through the
year 2000 with or without the proposed expansion.
16. ITE estimates that the proposed expansion will increase P.M.
peak hour trip ends from 436 vte's to 602.5 vte's, a 166.5 vte
increase. The applicant was made aware that the road impact fee
will be approximately $32,500. This fee could be phased according
to development phasing.
17. Sewer: No additional allocation needed due to the credit from
removal of the theater building.
18. Lot merger: The 2 Corporate Way parcel is being used to
satisfy zoning and parking requirements on the 100 Dorst Street
parcel. This results in the two (2) lots being merged. The plans
and survey plat should be revised to reflect the merger of these
two (2) lots.
19. Proposed streets: The City's Official Map shows a proposed
street running easterly between the main retail/office building and
the proposed retail building. This proposed street then intersects
with an extension of Mary Street which crosses the easterly portion
of the 2 Corporate Way parcel. These planned streets are shown on
the preliminary plat. The applicant should meet with the City
Council to obtain comments regarding the proposal to construct a
portion of a building within a planned public street r.o.w. which
appears on the City's official map. These comments should be
submitted with the final plat application.
20. Lighting: Existing and proposed exterior lighting will
consist of the following:
--- 12 70 watt metal halide lamps with downcasting and shielded
fixtures on 12 foot poles.
--- 19 175 watt metal halide lamps with downcasting and shielded
fixtures on 16 foot poles.
--- 4 150 watt high pressure sodium lamps with downcasting and
shielded fixtures on 16 foot poles (street lights along
Corporate Way).
21. Details of any building mounted lights should be approved by
the City Planner prior to permit issuance. The site plan should be
revised to depict each of the three (3) types of lights proposed
with different symbols and the symbols labeled.
22. Ramada access: The applicant is proposing an access to the
Ramada Inn property. This access was approved when the 2 Corporate
Way parcel was subdivided from the Ramada Inn parcel. This is a
floating r.o.w. which should be shown on the survey plat. If the
Ramada Inn wants to connect to this access then they will need to
revise their site plan.
3
23. Dumpsters: Screened dumpsters are proposed. Plan should
indicate the type of screening to be used.
24. Bus shelter: The applicant is proposing a bus shelter along
Dorset Street in the same general location as previously approved.
25. Other: The survey plat should be revised to no longer show
the land swap with the Anchorage Motor Inn since this land swap is
no longer part of this application.
DECISION & CONDITIONS
Based on the above Findings of Fact, the South Burlington Planning
Commission approves the preliminary plat application of Century
Partners for a planned unit development consisting of 87,457 square
feet of general office and shopping center use in four (4)
buildings, 100 Dorset Street and 2 Corporate Way, as depicted on a
three (3) page set of plans, page one (1) entitled "100 Dorset
Street, South Burlington, Vt" prepared by Trudell Consulting
Engineers, dated 7/1/95, with the following stipulations:
1. All previous approvals and stipulations which are not
superseded by this approval shall remain in effect.
2. The applicant shall post a $36,525 landscape bond prior to
issuance of a zoning permit. The bond shall remain in effect for
three (3) years to assure that the landscaping takes root and has
a good chance of surviving.
3. The plans shall be revised prior to submittal of the final plat
application as follows:
a) The planning data on the site plan shall include the
building coverage information for the Cl and CD1
Districts and existing and proposed front yard coverage
along Dorset Street.
b) The site plan shall be revised to remove all parking
spaces located within the 80 foot building envelope along
the proposed Mary Street extension.
c) The site plan and survey plat shall be revised to reflect
the merger of the 100 Dorset Street parcel and the 2
Corporate Way parcel.
d) The site plan shall be revised to depict each of the
three (3) types of lights proposed with different symbols
and the symbols labeled.
e) The site plan shall be revised to indicate the type of
screening to be used around the dumpster storage areas.
4
f ) The site plan shall be revised to show one (1) additional
hydrant at the Corporate Way entrance at a location
approved by the Fire Chief.
g) The site plan shall include a method for storm water
retention approved by the City Engineer.
4. Pursuant to Section 12.406(b) of the zoning regulations, the
Planning Commission modify's the front yard setback requirement to
allow building "A" to be 20 feet from the Dorset Street r.o.w.
5. The street trees along Corporate Way shall be at least 3-3j"
caliper as recommended in the City Center Streetscape Guidelines
Handbook. The planting schedule shall be revised to reflect this
minimum size.
6. Pursuant to Section 26.256(b) of the zoning regulations, the
Planning Commission is willing to grant a parking waiver. The
exact number of spaces to be waived shall be determined at final
plat.
7. For the purposes of calculating required road impact fees under
the South Burlington Impact Fee Ordinance, the Planning Commission
estimates that the proposed shopping center expansion will generate
166.5 additional vehicle trip ends during the P.M. peak hour.
8. All exterior lighting shall be downcasting and shielded and
shall not cast light beyond the property line. Any change in
lighting shall be approved by the City Planner prior to
installation. Applicant shall submit, prior to issuance of a
zoning permit, details and cut -sheets of all exterior building
mounted lights for approval by the City Planner. The street
lighting proposed along Corporate Way shall conform with Chapter 5
of the City Center Streetscape Design Guidelines Handbook.
9. The bus shelter shall be constructed prior to occupancy of
building "A".
10. Prior to final plat submittal, the applicant shall meet with
the city Council to obtain comments regarding the proposal to
construct a portion of a building within a planned public street
r.o.w. which appears on the City's official map. These comments
shall be submitted with the final plat application.
11. All streetscape and road widening improvements along Corporate
Way shall be done in accordance with the City Center Streetscape
Design Guidelines Handbook.
12. Prior to issuance of a zoning permit, the applicant shall post
bonds to cover the costs of proposed sidewalk improvements along
Corporate Way and the Corporate Way widening. The amount of the
bonds shall be approved by the City Engineer.
W"
13. Prior to final plat submittal, the applicant shall submit a
development phasing plan which also clearly shows or describes the
parking areas to be constructed with each phase.
14. The applicant must submit the revised final plat application
within 12 months or this approval is null and void.
Chairman or Clerk
South Burlington Planning Commission
Wz66 S /
Date
6