Loading...
HomeMy WebLinkAboutAgenda 09_SD-20-08_500 Old Farm Road_OBrien Farm Road LLC_SK#SD‐20‐08  Staff Comments 1 1 of 4  CITY OF SOUTH BURLINGTON  DEVELOPMENT REVIEW BOARD  SD‐20‐08_500 Old Farm Road_OBrien Farm Road  LLC_SK_2020‐03‐04.docx  DEPARTMENT OF PLANNING & ZONING   Report preparation date: February 20, 2020  Plans received: January 24, 2020  500 Old Farm Road  Sketch Plan Application #SD‐20‐08  Meeting date: March 4, 2020  Applicant  O’Brien Farm Road, LLC  1855 Williston Road  South Burlington, VT 05403  Engineer  Krebs & Lansing Consulting Engineers, Inc.  164 Main Street  Colchester, VT 05446  Property Information  Tax Parcel 1260‐0200F; 0970‐00255; 0980‐00055  Mixed Industrial Commercial, Residential 1, Commercial 1 Limited Retail, Residential 12  64.51 acres, 5.5 ac, 8.2 ac , 7.2 ac, 5.3 ac   Location Map        PROJECT DESCRIPTION  Sketch plan application #SD‐20‐08 of O’Brien Farm Road, LLC to subdivide five (5) existing lots totaling  85.44 acres, one of which is developed with an existing barn, into seven (7) lots ranging from 0.51 acres  (Lot 18) to 37.3 acres (Lot 5) for the purpose of transferring ownership and better aligning parcel  boundaries with zoning districts, 500 Old Farm Road.  #SD‐20‐08  Staff Comments 2 2 of 4  CONTEXT  The project consists of five lots located on either side of Old Farm Road.  Staff refers the applicant to the  included plan for an overview of the involved lands.  Lots west of Old Farm Road include existing Lots 16  and 17, which were created by the applicant as part of the O’Brien Home Farm PUD.  The applicant is  proposing to subdivide these two lots and create Lot 18, a 0.51 acre lot.  Lots east of Old Farm Road  include existing Lots 1, 2 and 3, which the applicant is proposing to re‐subdivide into five (5) lots. No  development is planned as part of this application.     PERMIT HISTORY  The Project involves several zoning districts.  LDR 15.02B requires PUD review for all applications in  which the total area of all involved lands is ten (10) acres or more.  The development review board  created Lots 16 and 17 as part of PUD approval #SD‐17‐17.  These lots are shown on the plat associated  with #SD‐17‐17 but the master plan decision #MP‐16‐03 (as modified by #MP‐17‐01) reserves these lots  for future development.  Lots 16 and 17 are therefore already part of a PUD and the Board must  approve a request to remove them from that PUD in order to involve them in a different PUD.    COMMENTS  Planning Director Paul Conner and Development Review Planner Marla Keene (“Staff”) have reviewed  the plans submitted on 1/24/2020 and offer the following comments.  Comments for the Board’s  attention are indicated in red.    ZONING DISTRICT & DIMENSIONAL REQUIREMENTS  Setbacks, Coverages & Lot Dimensions  Minimum lot sizes by zoning district are as follows.  Mixed Industrial Commercial  40,000 sf for all uses  Residential 1 PRD (R1‐PRD)  40,000 sf for all uses  Commercial 1 Limited Retail (C1‐LR)  20,000 sf for non‐residential uses, 8,000 sf or less  for residential uses  Residential 12  40,000 sf for non‐residential uses, 8,000 sf or less  for residential uses    The applicants proposed lot sizes and the zoning districts included in each lot are listed.  Lot 1  376,800 sf  C1‐LR and Residential 1  Lot 2  268,200 sf  C1‐LR and Residential 1  Lot 3  606,400 sf  R1‐PRD and Mixed Industrial  Commercial  Lot 4  529,700 sf  R1‐PRD and Mixed Industrial  Commercial  Lot 5  1,624,800 sf  C1‐LR and Mixed Industrial  Commercial  Lot 16  292,700 sf  R1‐PRD  Lot 17  230,900 sf  C1‐LR and Residential 12  Lot 18  22,200 sf  R1‐PRD and Residential 12  #SD‐20‐08  Staff Comments 3 3 of 4  Staff recommends the Board ask the applicant whether their intent is to remove Lots 16 and 17 from the  PUD approved in SD‐17‐17 and create a new PUD containing only Lots 16, 17 and 18, or to create a  single PUD involving parcels 16, 17, 18 and those currently proposed on the east side of Old Farm Road.  The applicant has stated in their cover letter the proposed subdivision enables the land sales necessary for  future development to occur in an efficient manner, and also separates the land parcels in line with the  underlying zoning districts.    1. Staff considers the proposed subdivision specifically fails to separate parcels along zoning district  boundaries, and instead crosses zoning district boundaries with all but one proposed lot line, and  recommends the Board ask the applicant to further enumerate why they have made this assertion.  If  the applicant’s goal is truly to subdivide along zoning district boundaries, Staff recommends the Board  request the applicant revise their lot lines to do so.  The applicant’s provided plans only show the proposed revised interior lot lines, making it unclear when a  lot line overlaps a zoning district boundary or easement where the property ends.    2. Staff recommends the Board request the applicant show the Board the proposed outer boundary of each  lot, and at the next stage of review use a different linetype from other lines on the plans to show the  outer boundary of each proposed lot.  3. Lot 18 includes lands in zoning districts requiring a minimum lot size of between 8,000 sf and 40,000 sf,  depending on use.  The proposed lot size is approximately 22,200 sf.  Staff considers the portion of Lot 18  within the R1‐PRD district to be undevelopable as proposed, and the portion within the Residential 12  district to only be developable with residential uses.  Staff recommends the Board discuss with the  applicant their intended use for Lot 18.  As no development is proposed at this time, Staff considers other dimensional standards are not applicable.   Both the C1‐LR and the mixed industrial commercial districts include standards encouraging innovation of  design and layout, the purpose of which is to encourage more efficient use of land for development,  promote shared parking opportunities, provided coordinated access to and from commercial developments  via public roadways, and maintain service levels on public roadways with a minimum of publicly financed  roadway improvements.    4. The applicant has offered to record a notice of conditions stating that for zoning purposes the involved  parcels will be viewed as one lot.  Staff recommends the Board as the applicant if they’re intending to  consider all involved lots as one lot, or consider one lot on each side of Old Farm Road.   5. Existing lots 16 and 17 are already encumbered by a notice of conditions tying them to the remainder of  the O’Brien Home Farm recorded as part of subdivision approval #SD‐17‐08.  Staff considers the  applicant must amend that previously recorded notice to remove those two parcels in order to tie them  to the current proposal.  Staff recommends the Board request the applicant provide a draft notice of  conditions at the next stage of review. SUBDIVISION STANDARDS  Subdivision standards pertain to water and wastewater capacity, natural resource protection, traffic,  visual  compatibility  with  the  surrounding  area,  open  space,  fire  protection,  relationship  to  the  Comprehensive Plan, and public infrastructure. The proposed lots all have frontage of on a public street, contain limited natural resources, and are not  proposed for development at this time.  Staff considers there do not appear to be issues with compliance  with subdivision criteria, but they will be reviewed in detail at the next stage of review.      #SD‐20‐08  Staff Comments 4 4 of 4  RECOMMENDATION  Staff recommends that the Board discuss the Project with the applicant and conclude the meeting.     Respectfully submitted,    Marla Keene, Development Review Planner