Loading...
HomeMy WebLinkAboutAgenda 07B_SD-19-19_47 Tilley Dr_Pizzagalli_plansT T T T T T T T DD D DDDSSSSSSSSW W W W W W W W WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSSSSDDDDDDDDDDTILLEY DRIVE25'FRONTSETBACK25'FRONTSETBACKPROPOSEDBUILDING40' x 60'35'SIDESETBACK35'SIDESETBACKSTORMWATER TREATMENT AREAEXISTINGELEV=3905'5'5'10'8'30'24'DLHCEJPKJPK05/28/20191" = 20'19-0901MOUNTAIN VIEW OFFICE PARKLOT 8 SITE DEVELOPMENTCONCEPTUAL SITE PLANPIZZAGALLI PROPERTIES, LLC462 SHELBURNE ROAD, SUITE 101BURLINGTON, VT 0540106/07/2019 REVISIONS PER CITY COMMENTS JPKNOTES:1. CONTOURS SHOWN ON THIS PLAN ARE BASED ON THE DIGITAL ELEVATION MODEL DATA OBTAINED FROM THE 2004AERIAL PHOTOGRAPHY DONE FOR THE CHITTENDEN COUNTY METROPOLITAN PLANNING ORGANIZATION AND FIELDSURVEY PERFORMED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC.2. PROPERTY LINES DEPICTED ON THIS PLAN ARE BASED ON A PLAN ENTITLED SUBDIVISION PLAT, MOUNTAIN VIEW OFFICEPARK, TILLEY 3 SUBDIVISION, TILLEY DRIVE AND OLD FARM ROAD, SOUTH BURLINGTON, VERMONT, DATED 07/07/08 ANDLAST REVISED 09/10/08, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC.3. EXISTING FEATURES DEPICTED ON MVBP LOT A ARE BASED ON A PLAN ENTITLED MOUNTAIN VIEW BUSINESS PARK, SITEPLAN, DATED 03/06/02 AND LAST REVISED 08/03/05, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC.4. EXISTING FEATURES DEPICTED ON MVBP LOT B ARE BASED ON A PLAN ENTITLED MOUNTAIN VIEW BUSINESS PARK LOT BSITE DEVELOPMENT, SITE PLAN, DATED 01/19/04 AND LAST REVISED 04/12/06, PREPARED BY DONALD L. HAMLINCONSULTING ENGINEERS, INC.5. TILLEY DRIVE UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON A PLAN ENTITLED "TILLEY II SUBDIVISION,ROADWAY PLAN VIEW", SHEET #2, DATED 05/26/04 AND LAST REVISED 04/04/05, PREPARED BY DONALD L. HAMLINCONSULTING ENGINEERS, INC.6. PROPOSED FEATURES DEPICTED ON MVOP LOT 6 ARE BASED ON A PLAN ENTITLED "MOUNTAIN VIEW OFFICE PARK, LOT 6SITE DEVELOPMENT, OVERALL SITE PLAN", DATED 09/30/2011 AND LAST REVISED 04/18/2012, PREPARED BY DONALD L.HAMLIN CONSULTING ENGINEERS, INC.7. PROPOSED LANE CONFIGURATIONS ALONG VT ROUTE 116 SHOWN ON THIS PLAN ARE BASED ON A PLAN ENTITLED"HINESBURG ROAD TURN LANES, SIGNS AND PAVEMENT MARKINGS" SHEET #7, DATED 03/30/2012 AND LAST REVISED02/11/2019, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC.8. WETLANDS SHOWN ON THIS PLAN WERE DELINEATED BY GILMAN & BRIGGS ENVIRONMENTAL ON 04/28/06.PROJECT INFORMATION - MVOP LOT 8EXISTING NEWAREA(SF/AC)% OFTOTALAREA(SF/AC)% OFTOTALLOT SIZE43,834 1.01 100.00 43,834 1.01 100.00BUILDING COVERAGE4,234 0.10 9.9000 2,400 .06 5.94PARKING & DRIVE COVERAGE3,070 0.07 6.9300 12,974 0.30 29.70SIDEWALK/PATH COVERAGE2,344 0.05 4.95MISC. COVERAGE1,636 0.04 3.96TOTAL COVERAGE7,3040.17 16.8319,3540.45 44.55FRONT YARD SETBACKBASED ON 25' SETBACK, HINESBURG RD & TILLEY DR FRONT YARD SETBACK SIZE10,0790.23 100.00 FRONT YARD COVERAGE2,219 0.05 21.74ZONING DISTRICT: INDUSTRIAL & OPEN SPACEPARKING STATISTICSREQUIRED: 12 CONVENIENCE STORE: 2,400 SF GFA x 5 SPACES PER 1000 SF GFAPROVIDED: 30