Loading...
HomeMy WebLinkAboutSD-18-14 - Supplemental - 1731 Hinesburg RoadCITY OF SOUTH BURLINGTON DEVELOPMENT REVIEW BOARD SD-18-14_1731 Hinesburg_Auclair_Sketch_2018-05- 15.docx #SD-18-14 Staff Comments DEPARTMENT OF PLANNING & ZONING Report preparation date: May 10, 2018 Plans received: April 16, 2018 1731 Hinesburg Rd Sketch Plan Application #SD-18-14 Meeting date: May 15, 2018 Owner/Applicant Engineer Ernest N. Auclair Family Trust Trudell Consulting Engineers PO Box 5324 478 Blair Park Rd. Essex Junction, VT 05453 Williston, VT 05495 Propertv Information Tax Parcel 0860-01751 Southeast Quadrant Neighborhood Residential (SEQ-NR) and Natural Resource Protection (SEQ-NRP) 132 acres Location Map 1 SD-18-01 Staff Comments PROJECT DESCRPTION Sketch plan application #SD-18-14 of Ernest N. Auclair Family Trust to subdivide an existing parcel developed with a single family dwelling into two lots of 15 acres (Lot #1) and 117 acres (Lot #2), 1731 Hinesburg Road. CONTEXT The project consists of subdividing off a 15 ac. parcel (referred to on the plans as "New Lot 3") from the larger 117+/- ac. parcel (referred to on the plans as "Remainder of Auclair Trust Parcel, Lot 2"). The new 15 ac. parcel will include the existing 8-bedroom farmhouse and one existing barn. There is no new construction proposed. The State requires the applicant to provide a location for a future replacement wastewater system should the existing system fail. There is also a future replacement well site shown as required by the State. Since no new construction is proposed, the Board's authority in this matter is to confirm the proposed subdivided lots comply with the dimensional requirements of Article 3 and Appendix C, and the applicable subdivision general standards of Article 15.18. COMMENTS Development Review Planner Marla Keene and Administrative Officer Ray Belair, hereafter referred to as Staff, have reviewed the plans submitted by the applicant and have the following comments. A) ZONING DISTRICT & DIMENSIONAL REQUIREMENTS The 15 acre parcel is located entirely within the SEQ-NR district. The remaining 117 acre parcel is located partially within the SEQ-NR district and partially within the SEQ-NRP district. Dimensional standards described in Appendix C are the same for both districts. Existing development on the 15 acre parcel consists of a single-family farmhouse and a barn. Existing development on the 117 acre parcel consists of a dairy barn and farm roads, which are eligible for agricultural exemption and not subject to DRB review. SEQ-NR & SEQ- NRP Required 15 Acre Parcel 117 Acre Parcel ✓Min. Lot Size 40,000 sq. ft. >40,000 sq. >40,000 sq. ft. ft. ✓Max. Building 15% 1.69% N/A Coverage' ✓Max. Overall 30% 2.64% N/A Coverage' ✓Min. Front 20 ft. >20 ft. N/A Setback 2 SD-18-01 Staff Comments ✓Min. Side 10 ft. > 10 ft. N/A Setback ✓Min. Rear 30 ft. > 30 ft. N/A Setback Building Height 28 ft. Unknown, N/A (pitched roof) no change proposed ✓Proposed to be in compliance 1. Includes non-agricultural exempt elements only B) SUBDIVISION STANDARDS 15.10 Lot Layout A. Lots shall be laid out in such a way that they can be developed in full compliance with these land development regulations, and giving consideration to topography, soils and drainage conditions. B. Except within the City Center FBC District... a width to length ratio of one to five (1:5) shall be used as a guideline by the Development Review Board in evaluating lot proportions. Developments consisting predominantly of square or roughly square lots or lot with an excessive length to width ratio (i.e. spaghetti lots) shall not be approved. The proposed lots do not conform to the lot ratio guidelines of 15.1013 though they also do not represent the smallest feasible subdivision of the proposed lots. Staff considers that the overall size of the proposed lots precludes concern about the length to width ratio. Staff considers that the topography, soils and wetland conditions of the subdivided lots do not preclude development. The applicant has not performed a full boundary survey on the 117 acre parcel. Staff recommends the Board discuss whether they will accept the final plat application without a full boundary survey. Staff considers that the proposed property far exceeds the dimensional minimums of the district and has no concerns about accepting an application without a full boundary survey for the 117 acre parcel. 15.18A General Standards The project's design must respect and provide suitable protection to wetlands, streams, wildlife habitat as identified in the Open Space Strategy, and any unique natural features on the site. The 117 acre lot contains a large area of wetlands at the southeast corner according to State wetland mapping. Staff considers that there is sufficient area available on the lot available to allow future development without necessitating wetland impacts. The applicant has supplied a site plan indicating shallow ledge over a portion of the 15 acre lot. Staff has no concerns about the ability of the subdivision to protect these natural resource areas. The Project is required to be visually compatible with the planned development patterns in the area, as specified in the Comprehensive Plan and the purpose of the zoning district(s) in which it is located. SD-18-01 Staff Comments Staff considers that the existing parcel is one of the largest in the area and the subdivision does not create any incompatibility with the planned development patterns or goals of the Comprehensive Plan. The remaining subdivision standards pertain to projects which involve construction. No construction is proposed as part of this subdivision. RECOMMENDATION Staff recommends that the Board discuss the Project with the applicant and conclude the hearing. Respectfully submitted, Marla Keene, Development Review Planner 4