Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit Permanent Sign SN-19-43 - Walgreens
Permit Number SN- 10 southburlington Application for Permanent Sign PLANNING & ZONING Permittee and Property Information 1) Applicant/Contact (Name, mailing address, phone and email) Cima Network - Jon Bennett 121 New Britain Blvd. Chalfont, PA 18914 jbennett@cimanetwork.com 267-245-8754 2) Owner of Record (Name, malting address) Antonio B. Pomerleau y_Lc 69 College St. P.O. Box 6 Burlington, VT 05402 3) Sign location (include business name and address) Walgreens 39 Hinesburg Road South Burlington, VT 05403 / NIA or not requested 1) Principal Public Facade (see definition in South Burlington Sign Ordinance, p.7) Describe (include street, descriptor, or compass direction as appropriate) North, Facing Parking lot Area of Principal Public Facade 2310 SF 2) Area of fagade to which sign will be attached: Wall Sign A 880 sf Wall Sign B 880 sf 3) Sign Size: Square Footage of Sign A: 74.75 sf Sign B: 7•4 sf 4) Type of Illumination@nternal Other0one S) Sign Type0anel oacewaoutout Letters Please attach sketches of at/ proposed and existing signs. 1) Property information (include property size, road frontage, number of public accesses) N/H N/A 2) Proposed Sign Size: Square Footage of Sign: N/A sf Overall Height of Sign: N/A Please attach sketch showing location of free-standing signs, including distances from property lines and public entrances. if in Sign Design District, not whe er t eredk-en approved Master Sign Permit. An—el Nilally si Js stt g/5/1 g Applicant Signature: Jon B19.09.OS _ e o" Date: r Property Owner Signature: Date: 017 Y ........................................................................................................ Do not write below this line — Administrative Officer Use Only Application: ejected .pproved Code Officer Signature: as Fee: 0 r Date: l 2-0 2 ! 10 Last revised 1112018 c1ma k IF— Dear Recipient: As you may be aware, many Rite Aid locations will be converting to Walgreen's in the near future. Cima Network has been hiredby Walgreen's Corp.to move forward with obtaining signage permits at the address listed below.lnorderto accomplish this Cima needs a signed letter of authorization fromthe property owner or an authorized agent. Please take a moment to review the designs provided, complete this form and email it to walgreens@cimanetwork.comor fax it to 267.308.0577 Thank you. I,Y (�es-� 6Vl.6 owneroragentof theownerfor the property locatedat39 HINESBURG ROAD SOUTH BURLINGTON, VT 05403 do hereby authorize CIMA Network Inc, and/or their agents, to obtain a I permits to install signage on the property listed above. Property Owner Information: .� Name:_ Address: Il 11 Yy �"►'r� V ! I Phone: :✓� Fax: '`�U� 1 j_ .. J — 1/ P Sign r Date: 121 NEW BRITAIN BLVD. CHALFONT, PA 18914 267.308.0575 267.308.0577 WWW.CIMANETWORK.COM Dalila Hall }m: Jon Bennett <jbennett@cimanetwork.com> Wednesday, September 18, 2019 10:08 AM To: Dalila Hall Subject: Re: 39 Hinesburg Road Permit application Good morning Dalila, I wasn't able to get the check until this morning but I have shipped it FedEx overnight. The tracking number is 776270036143 and you should receive it Thursday. Thank you! On Tue, Sep 17, 2019 at 3:11 PM Dalila Hall <dhall@sburl.com> wrote: Thank you for clarifying, Jon. This explanation is sufficient. I'll keep an eye out for the check. From: Jon Bennett <jbennett@cimanetwork.com> Sent: Tuesday, September 17, 2019 1:03 PM To: Dalila Hall <dhall@sburl.com> Subject: Re: 39 Hinesburg Road Permit application Good afternoon Delila, On sheet (4) the red box is there to illustrate where the existing Rite Aid Signs were positioned in relation to the new Walgreens signs. We also use this to show our installers where they will need to use touch up paint. On sheets (5) and (6) we show the signs boxed individually for square footage. Please let me know if this explanation is helpful or if you would still like me to have the drawings updated. I will get an additional check cut for $55 and have it shipped to you today. Thanks! On Tue, Sep 17, 2019 at 12:52 PM Dalila Hall <dhall@sburl.com> wrote: 1 Hello Jon: I'm following up on the application that was submitted. As presented in the application and the supporting materi�. you are applying for 2 signs: Wall Sign A is "Walgreens" and Wall Sign B is "Pharmacy". To reflect this in the supporting documents, I need you to resubmit Sheet #4 to show each of those signs with their own box around them. Right now there is one box around both signs. Additionally, the fee is on a per sign basis there fore we will need an additional check for $55 or I can shred/return the check you sent and a new check for $110 can be substituted. Please let me know how you would like to proceed. Thank you, Dalila Hall Zoning Administrative Officer City of South Burlington P: (802) 846-4115 From: Jon Bennett <ibennett@cimanetwork.com> Sent: Friday, September 13, 2019 10:00 AM To: Dalila Hall <dhall@sburl.com> Subject: Re: 39 Hinesburg Road Permit application Dalila, Thank you for the response and I look forward to hearing from you soon. z Branding Package Store 17447 39 Hinesburg Rd South Burlington, VT 05403 Standard W` c1ma building brands together ZONING CLASSIFICATION : C-6 FREESTANDING WINDOW SIGNS N/A - No Sign on property N/A TOTAL ALLOWED SO FT - Freestanding: 0.00 sq.it. Building:100 sq. ft. CODE CONSIDERATIONS CII'Y1C1'� WALL SIGNS Except as otherwise provided in this Ordinance, the total area of all wall signs shall not exceed five percent (5%) of the area of the principal public fagade of the building or one hundred (100) square feet, whichever is smaller. South Burlington Sign Ordinance Effective May 3, 2010 Page 24 (2) In no case shall any individual wall sign exceed fifteen percent (15%) of the area of the facade to which it is attached. Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 BANNERS & TEMP SIGNS Not Allowed. DRIVE THRU SYMBOLS DESCRIPTION: BYCIMA BYGC 72 120 Volt Junction Box X W Elect Whip: 1/2"0 x 6'-0" Lg Greenfield X LED Power Supply X `BA Blocking Req'd II Additional Structure Req'd. p Special Condition Applies ® Access Panel - Field Cut Additional Information Req'd. X ® Remove Remain As -Is © Relocate REVISIONS REVISION NQTE This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for All Electric Signs to be manufactured to meet the requirements of Client: Walgreens your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is U� FILE #E465295 UI 48 and installed to meet the requirements of Article 600 of the Owg By: LAH not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied a National Electrical Code and/or other applicable local codes. Date: 8.22.19 or exhibited in any fashion without the expressed constent of Cima Network, Inc. This includes proper grounding and bonding of the sign. Job#: 8251 Store #: 17447 Address: 39 Hinesburg Rd South Burlington, VT 05403 This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for All Electric Signs to be manufactured to meet the requirements of Client: Walgreens your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is U� FILE #E465295 UI 48 and installed to meet the requirements of Article 600 of the Owg By: LAH not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied a National Electrical Code and/or other applicable local codes. Date: 8.22.19 or exhibited in any fashion without the expressed constent of Cima Network, Inc. This includes proper grounding and bonding of the sign. Job#: 8251 Store #: 17447 Address: 39 Hinesburg Rd South Burlington, VT 05403 Cima Network Inc. This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for All Electric Signs to be manufactured to meet the requirements of Client: Walgreens Job#: 8251 Store #: 17447 121 New Britain Blvd. yourexclusive review, in connection with a project being proposed by Cima Network, Inc. it is O UI 48 and installed to meet the requirements of Article 600 of the Address: 39 Hinesburg Rd C I notto beshown to anyone outside your organization, norisitto beused, reproduced, copied FILE #E465295 National Electrical Code and/or other applicable local codes. Dwg B8. �H 9 Chalfont, PA 18914 or exhibited in any fashion without the expressed constent of Cima Network, Inc. This includes proper grounding and bonding ofthe sign. Date: 8.22.19 South Burlington, VT 05403 EXISTING PROPOSED Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 sl Letters (7.4 sq. ft.) FRONTWALL SIGNS ••ELEVATION BUILDING PAINT Patch and paint area shown within dotted line to match existing color I � SIGNAGE SQUARE FOOTAGE ELEVATION: EXISTING: 64.27 SQ FT PROPOSED: 82.15 SQ FT ALLOWED: 100.0 SOFT MMMUREV This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is U O FILE #E465295 All Electric Signs to be manufactured to meet the requirements of UI 48 and installed to meet the requirements of Article 600 of the Client: Walgreens Dwg B8LAH Job#: 8251 Store #: 17447 Address: 39 Hinesburg Rd / not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied National Electrical Code and/or other applicable local codes. Date: South Burlington, VT 05403 or exhibited in anyfashion without the expressed constent of Cima Network, Inc. This includes proper grounding and bonding of the sign. .22.19 1.8'_4_-1/4"_CHANNEL_LETTERS._ON RACEWAY ....__. 5 SCALE: 3/8" = 1' 0" (1) REQ'D CUSTOM-RW (18' 4-1/4" LONG RED WALGREENS RACEWAY LTRS) EXISTING MOUNTING CONDITION c1ma Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 PF2 PF3 PFi Pi U AM DETAIL 1 SCALE: 1-1/2" = 1' 0" SIDE VIEW $ SCALE: 3/8" = 1' 0" COLORS & FINISHES PF1.EFACE: #2793 Red Acrylic Face PF2.0RETURNS: Pre -finished White PF3.0TRIM CAP: Pre -finished White P1. 0 RACEWAY: SW TBD - BUILDING COLOR SIGN CONSTRUCTION 1. RETURNS: 040" Pre -finished Aluminum Returns Stapled/Pop Riveted To Backs 2. TRIM CAP: 1" Wide w/ #8 X 1/2" Long Pan Head Screws Painted To Match 3. FACES:.177" Thick #2793 Red Acrylic. 4. BACKS:.063 Thick Routed Aluminum 5. DRAIN HOLES: (3) 1/4"0 Per Letter. One Must Be As Close To Back As Possible 6. 7" RACEWAY: Extruded Aluminum Raceway w/ Lid Painted to Match Building Fascia 7. RACEWAY MOUNT TAB: 2" Raceway Mounting Tab Top And Bottom w/ 1/2" Mounting Hole. Max 4' On Center. 8. SCREW: Letter Back Attached To Raceway w/ #8 Tech Screw Minimum (4) Per Letter. ELECTRICAL (SIGN TO BE UL LISTED) 9. LEDS: Sloan Prism Red 10. WIRE: Secondary Low Voltage Led Wire 11. PASS THRU: Liquid Tite or Approved Equal. 12. POWER SUPPLY: Class 2 Power Supply 13. PRIMARY: 112" Conduit To Disconnect Switch Secure To Wall w/Straps By Others 14. SERVICE SWITCH: Located On End Of Raceway INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 15. HARDWARE: 3/8"0 Non -corrosive Hardware. Max 4' On Center Top And Bottom. BUILDING & FASCIA CONDITIONS 16. WALL SURFACE: Mansard Standing Seam Roof TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITION SIZE LOCATION AND QTY NOTED ON DWG SEAL ALL BUILDING PENETRATIONS THRU BOLT THRU BOLT LAG BOLT EXPANSION ANCHOR T- ----- NUT & WASHER WITH ALL -THREAD. RIV-NUTS WITH ALL -THREAD. UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" LAG BOLT INTO MIN 3)4" PLYWOOD. EXPANSION ANCHOR INTO SOLID ALUM ANGLE SLEEPERS SPANNING ALUM ANGLE SLEEPERS SPANNING (THREADS MUST PASS THRU CONCRETE OR GROUT FILLED MIN (2) STRUCTURAL WALL MEMBERS. MIN (2) STRUCTURAL WALL MEMBERS. PLYWOOD). ANTI -CRUSH SPACERS MASONRY. 1-1/4" MIN EMBEDMENT ANTI -CRUSH SPACERS AS REQ'D FOR ANTI -CRUSH SPACERS AS REQ'D FOR I AS REO'D FOR EIFS OR HOLLOW (NOT FOR HOLLOW MASONRY) EIFS OR HOLLOW FASCIA EIFS OR HOLLOW FASCIA FASCIA **ALL HARDWARE MUST BE NON -CORROSIVE** h requirements of Cl ient: Wal reens This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for All Electric Signs to be manufactured to meet the eq 9 your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is U UI 48 and installed to meet the requirements of Article 600 of the DW B LAH not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied ®L FILE # E465295 National Electrical Code and/or other applicable local codes. g y or exhibited in any fashion without the expressed constent of Cima Network, Inc. This includes proper grounding and bonding of the sign. I Date: 8.22.19 ESTIMATED WEIGHT 1 200 lbs. onREV 8.30.19 1 Job#: 8251 Store #: 17447 Address: 39 Hinesburg Rd South Burl'n ton, VT 05403 CI a 7'-4 3/4" 6" 3'-1 9/16" TYP TYP (MOUNTING POINTS) �e _1'-0"_CHANNEL LETTERS .................... 6 SCALE: 3/4" = 1' 0" (1) REQ'D WAG-PI2R-RW (7' 4-3/4" LONG RED PHARMACY RACEWAY LTRS) Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 e_DETAIL-_ ................ 1 SCALE: 1-1/2" SIDE VIEW..._..__ 6 SCALE: 3/8" = 1' 0" COLORS & FINISHES PF1.EFACE: #2793 Red Acrylic Face PF2.ERETURNS: Pre -finished White PF3.❑TRIM CAP: Pre -finished White P1. E RACEWAY: SW TBD - BUILDING COLOR SIGN CONSTRUCTION 1. RETURNS: 040" Pre -finished Aluminum Returns Stapled/Pop Riveted To Backs 2. TRIM CAP: 1" Wide w/ #8 X 1/2" Long Pan Head Screw Painted To Match 3. FACES:.177" Thick #2793 Red Acrylic. 4. BACKS:.063 Thick Routed Aluminum 5. DRAIN HOLES: (3) 1/4"0 Per Letter. One Must Be As Close To Back As Possible 6. 7" RACEWAY: Extruded Aluminum Raceway w/ Lid Painted to Match Building Fascia 7. RACEWAY MOUNT TAB: 2" Raceway Mounting Tab Top And Bottom w/ 1/2" Mounting Hole. Max 4' On Center. B. SCREW: Letter Back Attached To Raceway w/ #8 Tech Screw Minimum (4) Per Letter. ELECTRICAL (SIGN TO BE UL LISTED) 9. LEDS: Sloan Prism Red 10. WIRE: Secondary Low Voltage Led Wire 11. PASS THRU: Liquid Tite or Approved Equal. 12. POWER SUPPLY: Class 2 Power Supply 13. PRIMARY: 1/2" Conduit To Disconnect Switch Secure To Wall w/Straps By Others 14. SERVICE SWITCH: Located On End Of Raceway INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 15. HARDWARE: 3/8"0 Non -corrosive Hardware. Max 4' On Center Top And Bottom. BUILDING & FASCIA CONDITIONS 16. WALL SURFACE: Mansard Standing Seam Roof TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITION SIZE, LOCATION AND OTY NOTED ON DWG SEAL ALL BUILDING PENETRATIONS THRU BOLT THRU BOLT LAG BOLT EXPANSION ANCHOR NUT & WASHER WITH ALL -THREAD. RIV-NUTS WITH ALL -THREAD. UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" LAG BOLT INTO MIN 3i4" PLYWOOD. EXPANSION ANCHOR INTO SOLID ALUM ANGLE SLEEPERS SPANNING ALUM ANGLE SLEEPERS SPANNING (THREADS MUST PASS THRU CONCRETE OR GROUT FILLED MIN (2) STRUCTURAL WALL MEMBERS. MIN (2) STRUCTURAL WALL MEMBERS. PLYWOOD). ANTI -CRUSH SPACERS MASONRY 1-1/4" MIN EMBEDMENT ANTI -CRUSH SPACERS AS REfl'D FOR ANTI -CRUSH SPACERS AS REQ'D FOR AS REQ'D FOR EIFS OR HOLLOW (NOT FOR HOLLOW MASONRY) EIFS OR HOLLOW FASCIA EIFS OR HOLLOW FASCIA FASCIA **ALL HARDWARE MUST BE NON -CORROSIVE** This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for All Electric Signs to be manufactured to meet the requirements of Client: Walgreens your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is U UI 48 and installed to meet the requirements of Article 600 of the DW By: LAH not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied s� FILE #E465295 National Electrical Code and/or other applicable local codes. g y or exhibited in any fashion without the expressed constant of Cima Network, Inc. This includes proper grounding and bonding ofthe sign. Date: 6.22.19 ESTIMATED WEIGHT�43 lbs. Job#: 8251 Store #: 17447 Address:39 Hinesburg Rd South Burlington, VT 05403 REV] 1 CODE CHECK CI SIGN CODE CHECK C I a SIGN CODE CHECK building brands together Page 1of6 building brands together Page 2of6 V3 General Site Information Other: C. When is the next available board meeting date? NA Project Name: Walgreens Date Requested: ' Street Address: 39 HINESBURG ROAD Date Completed: 7-23-19 1. Zoning Classification: Commercial 2. Permit Application Fee (if known): 3. Permit Time Frame (inc. expiration date): 20-30 days 4. Will code be changed in the near future? City, ST Zip: SOUTH BURLINGTON VT Zoning with city then building 05403 5. Permit Process as described in local code: Paul Conner, AICP Contact for zoning/Permitting: Director of Planning & Zoning Email Address: pconner@sburl.com (802) 846-4106 Contact Phone Number: Address: 575 Dorset Street Jurisdiction: City/Town: City of South Burlington or, County of: South Burlington, VT City, ST Zip: 05403 1. Special codes, overlays, sign districts, PUD's, colors, historical or other restrictions regarding freestanding or building signs for this particular property: NO 2. Are there any approval boards? ❑ Yes ® No If yes, Planning Review? ❑ Yes ® No A. What documents are required and when? NA Architectural Board? ❑ Yes ® No Design Review? ❑ Yes ®No B. How often does the board meet? NA Sign Criteria is reported as presented to us as of the Date Completed" Cima Network, Ina is not responsible for changes in local sign code after the completion date, nor for the review process, interpretations calculations or fees of local authorities. Where required by local authority, it is understood a permit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network Inc Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 210A Progress Drive Montgomeryville, PA 18936 office: 267.308.0575 infoCcimanetwork com toll free: 888.355.cima www.cimanetwork.com fax: 267.308.0577 55.00 MW Wall signs shall be permitted only in accordance with the following provisions: (a) Number of wall signs. The allowable number and area of wall signs shall be as set forth in Table 10 1 below. (b) Area of wall signs. (1) Except as otherwise provided in this Ordinance, the total area of all wall signs shall not exceed five percent (5%) of the area of the principal public fagade of the building or one hundred (100) square feet, whichever is smaller. South Burlington Sign Ordinance Effective May 3, 2010 Page 24 (2) In no case shall any individual wall sign exceed fifteen percent (15%) of the area of the fagade to which it is attached. (c) In the Dorset 6. Formula for calculating wall sign square footage Street/City Center Sign District, wall signs may not project above the roof or parapet of a building nor below the top of any first floor doorway unless permitted through the design review approval process. (d) It shall be unlawful for any person to erect, alter, maintain or relocate any wall sign that covers, wholly or partially, any wall opening or to erect, alter, maintain or relocate any wall sign that projects beyond the ends or top of the wall to which it is attached. A wall opening is any opening exclusively provided for a window, door or removable panel. (e) Multi -tenant buildings and multi - building properties (1) Lots on which there is located commercial development consisting of two (2) or more distinct and separate businesses ("multi -tenant buildings" or Sign Criteria is reported as presented to us as cf the "Date Completed"Cima Network Inc. is not responsible for changes in local sign code after the completion date, nor for the review process, interpretations, calculations orfees of local authorities Where required by local authority, it is understood a permit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network Inc. 210A Progress Drive Montgomeryville, PA 18936 office: 267.308.0575 toll free: 888.355.cima fax: 267.308.0577 Signs to be manufactured to meetthe requirements of Client: Wal " g reens This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for All Electric Si 9 yourexclusive review, in connection with a project being proposed by Cima Network, Inc. it is U UI 48 and installed to meet the requirements of Article 600 of the DW By: LAH notto be shown to anyone outside your organization, nor is itto be used, reproduced, copied e� FILE #E465295 National Electrical Code and/or other applicable local codes. g y orexhibited in any fashion without the expressed constent of Cima Network, Inc. Thisincludes proper grounding and bonding ofthe sign. Date: $.22.19 info@cimanetwork.com ,++,ww.cimanetwork. com i !�J Job#: 8251 Store #: 17447 . Address:39 Hinesburg Rd South Burlin gton, VT 05403 So , 9 CODE CHECK C I SIGN CODE CHECK C' a SIGN CODE CHECK IPUV3 building brands together Page 3of6 building brands together Page 4of6 (max sq footage — primary & secondary signs) 7. Sq Ft allowance for elevations: Primary: formula "multi -building properties") shall be entitled to additional wall signs whose allowable area and number shall be in accordance with the formula set forth in Table 1-0 1. (2) In a multi -tenant building, there shall be a maximum of two (2) wall signs per individual tenant. The maximum area of an individual wall sign shall be five percent (5%) of the individual tenant's storefront area, calculated as shown in Illustration 10- 1, or one hundred (100) square feet, whichever is smaller. (3) Owners of multi tenant buildings and multi - building properties located outside of the Dorset Street/City Center Sign District shall have the option to obtain a Master Signage Permit from the Development Review Board, in accordance with Section 8 of this Ordinance. Once a Master Signage Permit is obtained, all changes to signage for that property shall be reviewed in accordance with the provisions of Section 8 of this Ordinance. Multi -tenant buildings for which there is a valid Master Signage Permit may increase the maximum allowable area of all wall signs and individual tenant signs as provided in Table -10 1. A property owner choosing this option shall be responsible for allocating the allowable area of wall signs among individual tenants. (f) Areas of walls within which paint, lighting or other treatments are used to highlight or enclose an area of wall on which cutout letters or other signs are installed shall be deemed to be part of the wall sign for all intents and purposes of this Ordinance, and shall be subject to all applicable provisions of this Ordinance. (g) A wall sign shall not project from the wall in excess of nine (9) inches, except for raceway signs. A raceway sign may project up to fifteen (15) inches from the wall to which it is attached above (L) Side: formula (R) Side: formula Rear: formul Sign Criteria is reported as presented to us as of the "Date Completed" Cima Network Inc, is not responsible far changes in local sign code after the completion date, norfor the review process, interpretations, calculations or fees of local authorities. Where required by local authority, it is understood a permit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network Inc. CI C1A Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 210A Progress Drive office: 267.308.0575 info0cimanetwork.corn Montgomeryville, PA 18936 toll free: 888.355.cima www.cimanetwork.com fax: 267.308,0577 d 8. Are allowances transferable? NO 9. Total # of Wall Signs allowed per elevation: above 10. Min/Max height from top of sign to grade: NA 11. Can sign exceed roofline? ❑ Yes ® No 12. Maximum Letter Height: NA 13. Maximum projection from building face: above 14. Internal illumination allowed? ® Yes ❑ No Freestanding Signs Face replacement in tenant panel requires permit. And LL approval. 15. Formula for calculating F/S sign square footage (max sq footage — primary & secondary signs) 16. Number of F/S Signs allowed: above 17. Height Maximum: above 18. Clearance from grade to sign: above 19. Internal illumination allowed? ® Yes ❑ No 20. Set -back of sign from right-of-way to property line: above 21.(Directional signs) Is Yes.. supplied by permit required? center. 22. Maximum Sq Footage: above 23. Maximum Height: above 24. Does sign(s) count toward square footage? no 25. Number of signs allowed: above 26. Internal illumination allowed? ® Yes ❑ No OpeningGrand 26!Are temporary or "grand opening" signs allowed? ® Yes ❑ No 27. Is permit required? ® Yes ❑ No 28. Are freestanding temporary signs allowed? ® Yes ❑ No 29. Is permit required? ® Yes ❑ No 30. How long can signs be up? Banners and Pennants - It shall be unlawful for any person to erect, relocate, alter or maintain banners or pennants as defined in this Ordinance. However, properly displayed governmental flags shall be permitted, but not in excess of three different flags per lot. In addition, a business may display one flag, not exceeding six (6) square feet on which is depicted its name, emblem or logo, except in the Dorset Street/City Center Sign District where such is prohibited. Sign Criteria is reported as presented to us as of the "Date Completed-Cima Network, Inc. is not responsible for changes in local sign code after the completion date, nor for the review process, interpretations, calculations or fees of local authorities. Where required by local authority, it is understood a permit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network Inc. 210A Progress Drive office: 267.308.0575 Montgomeryville, PA 18936 toll free: 888.355.cima fax: 267.308.0577 requirements of Client: W al reens t meet the re u g This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for All Electric Signs to be manufactured o q your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is O UI 48 and installed to meet the requirements of Article 600 of the DW By: LAH not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied L FILE #E465295 National Electrical Code and/or other applicable local codes. 9 y or exhibited in anyfashion without the expressed constent of Cima Network, Inc. This includes proper grounding and bonding of the sign. Date: B.ZZ.19 info@cimanetwork.com - www. ci manetwork.com 1 Job#: 8251 Store #: 17447 Address:39 Hinesburg Rd 1 Sout h Burlington, VT 05403 C1 ma SIGN CODE CHECK C' a O building brands together Page 5of6 building brands together SIGN CODE CHECK P2 Page 6 of 6 Architectural Features NA Variance Information 1. Is there a variance appeals process? ® Yes ❑ No 2. Estimated Variance Application Fee? 1300.00 3. Variance Meeting Date: TBD 4. Application Deadline: TBD 5. Time required to process: 90 days 6. Documents Required # of sets of prints: 3 Plot Plan ® Photo of Existing ® Legal Description [-I NA Installation Drawings ® Building Elevations ® Stress Analysis ❑NA Graphic Drawing ® Selected Engineering Drawings ❑ Other: 7. Is current sign under a variance? ❑ Yes ®No 1. Are signed/sealed engineering drawings required? ® Yes ❑ No 2. How many sets? 3 3. Calculations and drawings both required? ® Yes ❑ No 4. Building/Structural code required? ®Yes ❑No 5. Building code year: Engineer to determine 1. Are signed/sealed engineering drawings required? ® Yes ❑ No 2. How many sets? 3 3. Calculations and drawings both required? ® Yes ❑ No Required for county 4. Electrical code year: Engineer to determine. 5. Check all necessary items: ® Electrical hook-up included with sign permit ® Electrical permit required by licensed electrician ® List of UL numbersNA ® UL Label visible after installationNA 1. Inspections required? ® Yes ❑ No 2. Third party inspections required? ® Yes ❑ No 3. Contact for inspection: South Burlington Inspections Contact Information: 802 846-4106 4. Advanced notice requirements: 48 hours Sign Criteria is reported as presented to us as of the "Date Completed"Cima Network Inc is not responsible for changes in local sign code after the completion date, norfor the review Process, interpretations calculations or fees of local authorities Where required by local authority, it is understood a permit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network Inc Cima Ne twork Inc. C 121 New Britain Blvd. Chalfont, PA 18914 210A Progress Drive Montgomeryville, PA 18936 office: 267.308.0575 info(ocimanetwork corn toll free: 888.355.cima www.cimanetwork.com fax: 267.308.0577 Sq Ft allowance for elevations: Primary: above (L) Side: above (R) Side: above Formula for calculating F/S sign square footage above (max sq footage — primary & secondary signs) Rear: above Sign Criteria is reported as presented to us as of the "Date Completed -Ctma Network Inc is not responsible for changes in local sign code after the completion date, nor for the review process, interpretations, calculations orfees of local authorities. Where required by local authority, It is understood a permit will be obtained prior to manufacture. Information provided herein may not be used or disclosed without written consent by Cima Network Inc 210A Progress Drive office: 267308,0575 Montgomeryville, PA 18936 toll free: 888.355.cima fax: 267.308.0577 This is an original, un unpubli shed drawing, treat P created b Cima Nehv rk Inc. o It is submitted 9 Y for All Electric Signs To be manufactured to meet The requirements of your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is O FILE # E 465295 UI 48 and installed to meet the requirements of Article 600 of the not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied National Electrical Code and/or other applicable local codes. or exhibited in any fashion without the expressed constent of Cima Network, Inc. This includes proper grounding and bonding of the sign. Client: Walgreens Dwg By: LAH Date: 8.22.19 infoCcimanetwork.com _ www.cimanetwork.com Job#: 8251 Store #: 17447 EM Address: 39 Hinesburg Rd South Burlington, VT 05403