HomeMy WebLinkAboutMS-19-01 - Supplemental - 0180 Market Street
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
April 10, 2019
Marla Keene
Planning & Zoning Department
South Burlington City Hall
575 Dorset Street
South Burlington, VT
Re: 180 Market Street (South Burlington Library + Senior Center + City Hall)
Dear Marla,
Please find attached Miscellaneous Application for the Development Review Board for a civic
building containing a library, senior center and city hall at 180 Market Street.
Accompanying the application is a narrative of the project, permitting waiver requests, list of
abutting property owners, and supporting documents.
We’d appreciate your review of the attached application and supporting documents for
consideration of approval by the Development Review Board. Feel free to contact us if you have
any questions or require additional information, (802) 655-5020 or sroy@wiemannlamphere.com.
Sincerely,
Steven Roy, Vice-President
Wiemann Lamphere Architects
CC:
Ilona Blanchard, City of South Burlington Project Director
Paul Boisvert, Senior Engineer/Principal, Engineering Ventures
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 1
List of Items Submitted
• Miscellaneous Application for the Development Review Board
• Project Location & Zoning
• Project Team
• Project Narrative
• Permitting Waiver Requests
• List of Abutting Property Owners
• Attachments illustrating waiver requests
o Attachment 1a Primary Frontage & Build-to-Zone
o Attachment 1b Frontage Landscaping
o Attachment 2a – Entrances
o Attachment 2b Building First Floor Plan
o Attachment 3 South Elevation (Primary Façade) First Floor Glazing
• Architectural
o Attachment 4a, b, and c – Axonometric Floor Plans
o Attachment 5a, b, and c – supporting views of Primary and Secondary Facade
• Site Plan (Draft)
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 2
Location Map
Zoning
Site
Site
Zone - T-5
Zone - T-4
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 3
Project Team
Applicant:
City of South Burlington
Ilona Blanchard, Project Director
IBlanchard@SouthBurlingtonVT.gov
802-846-4107
Architect:
Wiemann Lamphere Architects
Steven Roy, Vice President
sroy@wiemannlamphere.com
802-655-5020
Civil Engineer:
Engineering Ventures
Paul Boisvert, Senior Engineer/Principal, Engineering Ventures
paulb@engineeringventures.com
802-863-6225
Landscape Architect:
SE Group
Jason Hoover, Senior Associate
jhoover@segroup.com
802-862-0098
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 4
Narrative: 180 Market Street (Library, Senior Center, and City Hall)
A. Building summary
The new South Burlington Library, Senior Center, and City Hall is intended to create a
central destination for social, cultural, and informational resources; promote identity and
a sense of place accessible to individuals of all ages and backgrounds; capitalize on
design and proximity synergies that maximize functionality and usage; increase
opportunities for public engagement, learning and growth; cultivate a sense of
ownership, pride, and belonging while catalyzing compact growth and economic
development in City Center.
The building design seeks to achieve these goals by:
1. Being located in a central and very visible location on Market Street,
2. Creating spaces for people of all ages and abilities,
3. Providing various spaces for learning and creating, both individually and in group
settings,
4. Incorporating ideas from public engagement sessions and
5. Including functions that attract citizens to be engaged in their community.
Massing
The architecture consists of two volumes, addressing both the irregular shape of the lot
and the multi-functional use of the building. These volumes intersect and overlap, and
are articulated differently in materials, size, and position (see Attachment 5a).
The intersection of these volumes creates both a void for a community space, becoming
the Library’s, and consequently the City’s, living room. This void is echoed in front of
the living room with a recessed, covered outdoor space with high quality paving which is
also an extension of shared use path adjacent to the building entrance. This creates an
eddy for pedestrian and bicycle flow along Market Street and into the building where
conversation or a (small) soap box could occur.
On the second floor, the intersection of the two volumes becomes the South Porch and
extends the Library towards the street, creating a direct visual and aural connection
between the interior of the building and the public realm (see Attachment 5c).
Elevations and Materials
The façade at the ground floor, the main public service floor, is largely glass. This
transparency, while underscoring the visual connection between the inside and outside
is expressive of democracy and knowledge. This transparency also provides ‘eyes on
the street,’ attracts people to participate and benefit from the activities within this civic
center and lends to Market Street the excitement of the activity within the building.
The glazing mullions on the ground floor of the eastern volume has a playful pattern
(see Attachment 3), reflecting the children’s library which is contained within; the
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 5
western volume mullions are more structurally consistent and regular to reflect the
steadfastness of City Hall as representative of the public.
At the far western edge of the Market Street façade, the volume is highlighted by a thin
column of glass at the corner of the stairwell rising to the third floor of City Hall. This
column of glass will illuminate the public stair with daylight during the day, and allow
light to spill out of the building at night. The adjacent wide granite base supports the
upper stories. This panel of granite and zinc counterbalances the glass and give the
overall western volume solidity and presence.
The Market Street façade western volume features a granite base and the Market
Street façade eastern volume is primarily clay brick over a granite base course. Granite
and brick were chosen for their durability. The main volume of the upper stories is clad
in zinc, a material with integral color that will not change over time. Trespa, a wood
patterned cladding material, is used as an accent material in the upper stories of the
western volume to add warmth and contrast to the facade.
Along the east facade, it is anticipated that the portion of wall nearest the Market Street
may be a candidate for public art. This eastern elevation is the secondary façade. A
shorter elevation, it alternates between brick and granite. At the north end of this
façade, the material palette changes and reflects the different use of the interior space.
This material change assists in shortening the perceived length of facade.
Entry Portal
The criteria for the project included that the entrance be easily identifiable and located
by any member of the public and also unify the diverse public uses within.
The main entrance, where not clear glazing, is clad entirely with local granite. Towards
the center of the primary façade, it projects from the front of the structure within the void
created by the union of the western and eastern volumes. The smooth cut finish
distinguishes the portal’s importance in comparison to the nearby split faced granite in
the façade.
The doors are eight feet tall. Transom windows create additional height that adds
drama to the entrance. Above the transom windows, the volume of Vermont granite
provides a triple function: it adds weight and size that underlines the importance of this
feature of the building; it creates a balustrade for the South Porch above; and provides
a background for future signage needs.
Including the integral granite balustrade, this portal is over 19 feet in height. A glass
awning further signifies the importance of this primary access to the building. These
features combined create an entrance that is suitably grand while approachable as a
house by and for the people.
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 6
Building Program
Within the building, the first-floor lobby and corridor provide convenient public access to
the City Clerk’s counter, records and offices, the City information desk, the Auditorium,
the Public Library and a new Senior Center. The Senior Center includes a living room,
activity space and catering kitchen (usable by the whole building). The first floor Library
entrance opens directly onto the circulation desk, a living room space (periodicals, new
books and large print), and the children’s library (children’s collections, an activity room,
and story time, reading, toddler and tween areas). The second floor is entirely library,
housing the adult collection, digital lab, study, reading and meeting rooms, and teen
area.
Library staff office and processing areas are located adjacent to each major function,
while City management, the new Planning and Zoning counter and department al staff
are located on the third floor. City Hall public meeting rooms and shared staff support
spaces are also on the third floor. Please see Attachments 4a, b, and c for a partial
axonometric of the floor plan.
Site
Associated site work required by the construction of 180 Market Street includes an
extension of the City Center street grid, and a new entrance to the Rick Marcotte
Central School. The Central School surface parking area is reorganized to establish
new improved school bus circulation and pedestrian and bicycle connectivity as well as
ensuring replacement of all parking to retain pre-project levels solely for the school use.
Access for the adjacent Allard Square Senior lower level parking is reoriented and some
surface parking is added to the rear of the new Community Center. Please see
Attachment 6 for a draft site layout.
All of the applicable review standards are proposed to be met, with the exception of
those for which the applicant is requesting modification via a waiver as follows.
B. Modification of Standards/Waiver Requests
The Form Based Code, in 8.06 A. (1) of the Land Development Regulations, recognizes
that Civic sites and buildings are of special public importance. Civic Sites include
municipal buildings, libraries, municipal schools, public recreation facilities, and the land
on which the Civic building is located.
In order to provide greater flexibility to create a special architectural statement, the Land
Development Regulations allow the Development Review Board to modify certain
standards of the City Center Form Based Code District for Civic Buildings. In
considering this application, the Board has the authority to modify or waive the Build-to-
Zone, Glazing, Frequency of Entrances, and Frontage Buildout requirements of the T-5
Building Envelope Standards.
The Board must consider the following in making its determination:
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 7
(a) Presence of a public design process and formal recommendation from the
South Burlington City Council and/or School Board; (b) Consistency of the design with
an adopted municipal or school building design policy (if one exists); (c) Consistency of
the project with the written purposes of the applicable Transect Zone; and, (d)
Advancement, where appropriate, of the project with design elements specifically
encouraged within the applicable Transect Zone.
(a) Design Process and Formal Recommendation
The design strives to present a coherent identity that brings many people of different
ages, backgrounds and interests together in one place while providing functional value
in a quality setting.
This Civic building underwent a community outreach process whereby ideas were
sought, design opportunities were reviewed, and the overall priorities of the public were
established over multiple workshops and focus groups.
Over and over, participants in the design process used phrases such as “wow factor”,
quality materials, interior light, and opportunities for gathering to describe the desired
building qualities. Underlying themes were community, democracy and synergy. The
design criteria for this new building, the Library, City Hall, and Senior Center, included
that it make a statement and create identity as a civic structure.
Following the initial schematic design process, the project was vetted through several
meetings as costs and design elements were discussed with the City Council. At the
conclusion of this vetting process, the City Council authorized the City to proceed to
seek full funding for the project (successfully obtained in a public vote in November
2018).
The project was approved by the City Council and the public with the siting, massing
and openings substantially consistent with the current project design.
(b) Consistency of the design with an adopted municipal or school building design policy (if
one exists).
The City does not have a specific policy for City building design. This design has been
endorsed by the Library Board of Trustees and the Recreation and Parks Committee,
approved by the City Council for the public vote on project funding. The voters of South
Burlington turned out in high numbers and approved the funding for this building design
by a high margin.
(c) Consistency with the written purposes of the applicable Transect Zone.
The T-5 Building Envelope Standards Purpose [8.14 (A)] is “Emphasis is on Market
Street with high volume foot traffic. Create a street-oriented public realm that
encourages a dense downtown, multi-use/multi-purpose built environment. Retail and
other commercial uses must be on the ground floor, and mixed uses permitted above.
Parking (not including on-street parking) shall be away (or hidden) from the street.”
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 8
“Emphasis is on Market Street with high volume foot traffic.”
A design requirement for this Civic building was that the main entrance and main façade
be oriented towards Market Street, and that this entrance serve as the main entrance
for all the uses inside the building. This single entrance orients all pedestrian activity
towards the shared use path in the center of the façade on Market Street. The project’s
covered bicycle parking is directly off Market Street’s shared use path, just to the west
of the building.
The project also strove to carve out some public space for gathering on Market Street,
either for a formal speech or a casual 20-minute conversation, installing large stone
pavers along the shared use path. Public uses are concentrated on the ground floor
and towards Market Street. This includes the uses with the highest and most consistent
foot-traffic hour over hour – the Clerk’s Office and the Library – which are oriented
towards and located near the front entrance on Market Street.
“Create a street-oriented public realm that encourages a dense downtown multi-
use/multi-purpose built environment.”
Transparency between the interior public portions of the building and the public realm is
facilitated by floor to ceiling clear glass glazing for the majority of the frontage on Market
Street.
The building uses most of the land within the buildable lot, achieving a rate of two
square feet of building area for every square foot of lot area.
The building is multi-use and multi-purpose, including assembly/performance space,
public services, a library, and recreational and office spaces. It combines exercise with
learning, record keeping and dog licenses with art and senior lunches.
The building uses which are the most similar to retail type commercial are located on
the ground floor.
This building is designed to encourage foot traffic in support of a future vibrant City
Center.
(d) Design elements specifically encouraged within the applicable Transect Zone
The applicable Transect Zone (T-5) is comprised nearly completely by standards. The
only elements that are encouraged are referenced in the purpose statement, which the
team has addressed above in section (c).
In looking at the broader Form Based Code District, the Code includes the following
elements which are encouraged and included within the project:
Sustainable development of open land through pedestrian and bicycle connectivity
(“encourages sustainable retail, commercial, and mixed-use development of open
land, redevelopment of existing mixed use land and preservation and improvement
of residential areas through pedestrian and bicycle connectivity”;)
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 9
This Civic building is located on a shared use (pedestrian and bicycle) path which
connects to Dorset Street and Hinesburg Road. It includes many sustainable elements
and is aiming to meet a LEED gold standard. The site includes ample bicycle parking,
including covered spaces and indoor spaces. Showers and changing facilities are
provided for employee commuter use. The rear of the building will also have a direct
sidewalk connection to the entrance of the Central School, facilitating school and
afterschool use of the facility.
Walking and bicycling coincident with the automobile ( “encourage new development
and infrastructure that incorporates planned transportation corridors with walking
and bicycling coincidental with the automobile.”)
This project includes the development of a new support street that will have within the
right-of-way a sidewalk and a shared use path connection to the Central School.
Preserve the existing residential fabric and stimulate new mixed-use (“aims to
preserve the existing residential fabric while stimulating new mixed-use growth that
facilitates a safe and economically self-sustaining place to live and work.”)
This project is designed to support the growth and development of residents and
employees, their interconnectedness and involvement through access to knowledge
and information, activities, and democratic engagement. The project provides an
anchor amenity where someone can make a podcast, access language learning
materials, participate in a video conference call, attend a performance, or obtain a
marriage license.
This Civic site is designed as an anchor to the City and region as a whole serving
adjacent businesses, residents, and visitors.
Alleys (“Alleys are encouraged in the City Center Form Based Code District.”)
The building site design has a vehicular connection behind it for circulation both for the
public and the adjacent Allard Square property.
Requested Modifications to Standards:
T-5 Building Envelopment Standards for the Built-to-Zone (8.14(C)(4)) and for Frontage
Buildout (8.14(C)(5)), see Attachments 1a and 1b for illustrations.
The T-5 BES require a Primary Building Façade to be located within t he primary Build-
to-Zone, which is between 0’ and 6’ from the front lot line, for a length that is not less
than 75% of the length of the front lot line.
Per section 8.06(A) of the Land Development Regulations, the DRB has authority to
modify or waive the Build-to-Zone and Frontage requirements for this Civic site.
Request: We request a waiver of these requirements for the Primary Build-to-Zone.
In order to provide well-designed and comfortable public seating and opportunities
for gathering that would not be possible otherwise, the building is proposed to be set
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 10
back generally four feet, and more in o ther locations, from the outer edge of the
Primary Build-to-Zone.
The façade is within the secondary build-to-zone and provides the intended street wall,
defining the public realm, while the transparency of the façade creates a welcoming
atmosphere for this section of Market Street. The hardscape and planting plan for the
frontage treats Market Street as both a stream of pedestrian and bicycle traffic and
creates locations for people to stop, rest, tie shoes, read a book, or check their e-mail.
The minimal but soft greenery creates just enough of an offset and physical separation
against the front windows so that whether inside or outside people will have sufficient
personal space to feel comfortable. Eddies of paved areas adjacent to the right of way
support a conversation or picnic lunch on the several benches provided.
This additional set back will enhance the utility of the exterior space as a Civic site in
alignment with the stated purpose of the T-5 Transect Zone to create a street-oriented
public realm on Market Street.
T-5 Building Envelope Standards for Entrances (8.14 (C)(6)), see Attachment 2a, 2b and
2c for illustrations.
The T-5 BES require primary building facades to have entrances every 40 feet and
secondary building facades to have entrances every 60 feet.
The primary façade of this building is on Market Street and the secondary façade of this
building is on a new street perpendicular to and north of Market Street.
Per section 8.06(A) of the Land Development Regulations, the DRB has authority to
modify or waive the Frequency of Entrances requirements for Civic sites.
Request: We are requesting that the DRB waive the Frequency of Entrance
requirements for this project.
The stated purpose of the T-5 Standards is “emphasis is on Market Street with high
volume foot traffic”. The design for this building complies with this purpose statement
with a single, prominent main entrance to the building on Market Street which attracts,
creates, and concentrates additional pedestrian activity along this primary route.
As a Civic building fronting on Market Street, a single main entrance is desirable to
provide an easily locatable and understandable public entrance from the City’s new
pedestrian, bicycle and vehicular thoroughfare. The goal of a single entrance is to 1)
provide a focal point central to the building that expresses the importance of the building
as a unified civic structure, 2) create synergy among the uses within the building, and 3)
maximize the utility for each distinct public use.
The entrance features a granite and glass design that has a height of over 19’ from the
sidewalk, presenting the highest quality materials (cut granite) as the focal point of the
building, without being overly grandiose or unapproachable.
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 11
The east façade of the building runs along a new street. This secondary façade, for
security reasons (and due to circulation priority at the front and rear of the building), has
two doors which serve as emergency exits only. This façade provides a visual
connection between the new street and the interior of the children’s library and the
Senior Center, while not allowing physical entry into these spaces from the street.
Public buildings in the United States are unfortunately a target for highly visible and
horrific violence. The children’s library is also an area of special access concern due to
the interest in containing younger children in a safe space while providing them with the
freedom to engage in independent exploration and engagement.
The building has been designed so that all entries are into the main circulation corridor,
and from there providing a single public point of entry into each use (excepting the
auditorium).
The many storefront windows provide an alternate method to activate the streets and
provide eye-level interest with a direct visual connection between pedestrians and the
building interior.
Effective secure building design includes measures to deter, detect, delay, and respond
to attacks from human aggressors according to the Whole Building Design website,
www.wbdg.org. While portions of this building, namely the Senior Center and the
Library, are fully open to the public, the single point of entry into each public functional
area facilitates conscious and subconscious threat monitoring by staff and other users
of the space.
In the area of highest public use, the Library, access is overseen (but not actively
monitored) by the front information desk for the building as well as the circulation desk
within the library. The Children’s Library, as an added security measure, has a single
entrance within the library adjacent to the circulation desk, featuring glass doors which
may remain closed when small children are present.
The Senior Center, composed of a living room and activity area, features a welcoming
entry area visible from both the living room and the activity room. This limits unobserved
access to the functional space and nefarious activity.
Other considerations include energy conservation and efficient use of space on the
ground floor. Energy conservation measures and LEED standards require a vestibule
for each building entrance. On the ground floor, public entrance vestibules open onto a
corridor and not directly into program spaces. The double feature of vestibule and
corridor serve to regulate temperature within program and occupied areas despite
Vermont’s extreme temperature differentials.
In order to best serve the public, entries bring people into obviously welcoming and
informative places. A fair amount of space, changes in flooring, and other visual cues
mitigate the transition from outdoor conditions and appropriately orient and direct
visitors. Due to the many program needs on the ground floor, square footage for every
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 12
use has been optimized and as much use as possible has been wrung out of each
space, while still functioning as envisioned by the community.
Thus with first floor space at a premium, the interest in a single unified identity for the
building, security planning and energy goals, the design includes a main entrance on
Market Street, with ancillary entrances at the rear to facilitate both Central
School/Market Street pedestrian traffic directly through the building, and direct parking
lot access to the Senior Center and Auditorium.
T-5 Building Envelope Standards (8.14 (C)(7)) Glazing, see Attachment 3 for illustration.
The T-5 BES require primary building facades to be composed of glazing a minimum of
80% of the width of the first story of the primary building facade.
The proposed façade utilizes large amounts of storefront glazing throughout much of
the façade, yet falls short of the 80% requirement by approximately 5 linear feet.
Per section 8.06(A) of the Land Development Regulations, the DRB is granted authority
to modify or waive Glazing requirements for this Civic project.
Request: We request a waiver of the requirement that glazing cover 80% of the
width of the building façade on the ground floor.
The LDRs require a minimum glazing height of 7.5 feet on the façade facing Market
Street. This façade otherwise exceeds the FBC standard, with 89% of the first-floor
glazing being transparent (the FBC requires a 75% minimum). Each window exceeds
the height minimum of 7.5 feet by several feet. The upper story exceeds the Note 2
FBC standard of 30% glazing by 38.8%.
The portions that are not glazing, next to the glass stair column to the west, and
adjacent to the front door, are composed of Vermont granite. These serve as important
counterpoints to the glass stair column and main entrance, emphasizing the
transparency of each while grounding the building.
Given the high level of transparency on this façade which supports street connectivity
and the overall design intent that reinforces the symbolic nature of this civic building, a
waiver is requested to allow the project glazing on the first floor to compose a minimum
of 74% of the first story width.
525 Hercules Drive I Suite Two I Colchester, VT 05446 I Phone: 802.655.5020 I Fax: 802.655.6567 I wiemannlamphere.com
Page 13
List of Abutting Property Owners
Property
Address
Parcel
ID
Owner Owner Street
Address
Owner Town Owner
State
Owner Zip
146 Market
Street
0450-
0000.a
Allard Square
Limited
Partnership
412 Farrell Street,
Suite 100
South
Burlington
VT 05403
155 Market
Street
0450-
00005
Poon Trust,
LLC
1569 Essex Road Williston VT 05495
10 Market
Street
0450-
00010
South
Burlington
School District
550 Dorset Street
South
Burlington
VT 05403
180 Market Street
South Burlington, VT
Building Plan View –Primary Frontage & Build-to-Zone
March 25, 2019
RED DASHED LINE IS
OUTLINE OF 2ND FLOOR
PROPERTY FRONTAGE = 178.25 LF
BUILDING FRONTAGE = 159.75 LF
FRONTAGE BUILDOUT = 89.6% (85% MINIMUM REQ.)
PERCENT OF FRONTAGE BUILDOUT IN PRIMARY BUILD-TO ZONE = 0% (75% MINIMUM REQUIRED)
PERCENT OF FRONTAGE BUILDOUT IN SECONDARY BUILD-TO ZONE = 100% (0% MINIMUM, 25% MAXIMUM REQUIRED)
WAIVER REQUEST:
Within the T-5 Building Envelope Standards, Primary building
facades are required to be within the primary build-to-zone for
75% of the frontage. The build –to zone in T-5 is between 0’ and
6’ from the property line. We are requesting a waiver of this
requirement to allow for additional public seating and gathering
opportunities that would not be possible otherwise. This will
enhance the usability of the exterior space as a civic building (see
Attachment #1b also). This usability is in alignment with the stated
purpose of the T-5 district to place an emphasis on creating a
street-oriented public realm on Market Street.
Although the building is set back a few feet farther for the primary
build-to-zone, the façade is within the secondary build-to-zone.
Per section 8.06(A) of the Land Development
Regulations, the DRB is granted authority to modify or
waive Build-to-Zone and Frontage requirements for this
Civic project.
ATTACHMENT #1a
Primary Build-to Zone
Secondary
Build-to Zone
T-5 (C) Building Standards
(4) Build-to-Zone
(5) Frontage
T-5 TRANSECT ZONE PURPOSE
Emphasis is on Market Street with high volume foot traffic. Create
a street-oriented public realm that encourages a dense downtown,
multi-use/multi-purpose built environment. Retail and other
commercial uses must be on the ground floor, with mixed uses
permitted above. Parking (not including street parking) shall be
away (or hidden) from the street.
SS –Schizachyrium
scoparioum ‘Carousel’
PV -Panicum virgatum
'Shenandoa'
DP-Dennstaedtia
punctilobula
Entrance Paver
black/grey granite
2’X 3’ (flamed finish)
Front Paver
dusty grey herkemer
1’X 20” (flamed finish)
ATTACHMENT #1b
180 Market Street
South Burlington, VT
Landscaping Plan –Primary Frontage & Build-to-Zone
March 25, 2019
MAIN ENTRANCE
58’
98.6’
26’
96’
19.5’
EMERGENCY
EXIT ONLY
EMERGENCY
EXIT ONLY
180 Market Street
South Burlington, VT
Building Plan View –Entrances
March 25, 2019
ATTACHMENT #2a
T-5 (C) Building Standards
(6) Entrances
WAIVER REQUEST:
As a Civic building fronting on Market Street, a single main entrance is desirable to
provide a clear location for public entrance from the City’s new pedestrian
thoroughfare. The goal of a single entrance is to provide a focal point central to the
building that expresses the importance of the use. The entrance features a granite
and glass design that has a height of over 19’ from the sidewalk, presenting the finest
materials as the focal point of the building, without being overly grandiose or
unapproachable.
As a stated goal of the T-5 district, “emphasis is on Market Street with high volume
foot traffic”. For this reason, we have placed the prominent main entrance of the
building on Market Street to attract and create additional pedestrian activity along this
primary route. On the East façade of the building, we are seeking to provide visibility
into the children’s library, yet limit unsecure entrance points directly into the library.
For this reason, egress doors are provided but are not usable as entrances. Along the
east elevation, it is anticipated that the portion of wall nearest the Market Street
intersection will be a location for public art. This will provide an engaging element,
visible from both Market Street and the new street. At the north end of the east
façade, the material pallet changes and reflects the different use of the interior space,
providing a feeling of a different façade, thus shortening the overall perceived length
of the building. With many storefront windows, this will provide a direct visual
connection between the sidewalk and the building interior.
(Of note, the Form Based Code District section H requires “alternate compliance for
entrances in T4”, and specifically references only the T-4 BES listed in Section
8.13(C)(6)(a-e). There is no requirement for an alternate compliance approach in the
T-5 Zone, presumably because the stated purpose is to emphasize Market Street.)
ATTACHMENT #2b
MAIN ENTRANCE
EMERGENCY
EXIT ONLY
EMERGENCY
EXIT ONLY
180 Market Street
South Burlington, VT
First Floor –Access Control
March 25, 2019
Library
Senior Center
City Clerk
City Hall Offices
ATTACHMENT #2c
180 Market Street
South Burlington, VT
Birdseye view from southwest
March 25, 2019
180 Market Street
South Burlington, VT
South Elevation (Primary Façade) First Floor Glazing
March 25, 2019
12” GRANITE PILASTERS
ATTACHMENT #3
T-5 (C) Building Standards
(7) Glazing
(a)first story
(b)First story transparent
2nd FLOOR
3rd FLOOR
1ST FLOOR
WAIVER REQUEST:
Within the T-5 Building Envelope Standards, Primary building facades are required to have 80% of the width
of the first story be composed of glazing. The proposed façade utilizes large amounts of storefront glazing
throughout much of the façade, yet falls short of the 80% requirement by approximately 5 linear feet. Given
the high level of transparency at the first floor level, a waiver is requested to allow the project to have 74% of
the linear width of the first story be glazing.
Per section 8.06(A) of the Land Development Regulations, the DRB is granted authority to
modify or waive Glazing requirements for this Civic project.
LINEAR FEET OF WALL AT FIRST FLOOR = 159.75 LF
LINEAR FEET OF GLASS >7.5’ TALL = 119.16 LF OR
74.6% OF WALL LENGTH (80% MINIMUM)
89% OF GLASS AT FIRST FLOOR IS TRANSPARENT
(75% MINIMUM)
24” GRANITE PILASTERS
WALL LENGTH= 159’-9”
4’-3”6’-0”6’-0”6’-0”6’-0”3’-4”15’-4”24’-3”7’-4”7’-4”8’-4”8’-4”8’-4”8’-4”
ATTACHMENT #4a
180 Market Street
South Burlington, VT
First Floor (informational only)
March 25, 2019
ATTACHMENT #4b
180 Market Street
South Burlington, VT
Second Floor (informational only)
March 25, 2019
ATTACHMENT #4c
180 Market Street
South Burlington, VT
Third Floor (informational only)
March 25, 2019
ATTACHMENT #5a
180 Market Street
South Burlington, VT
Birdseye View from southeast (Market Street is to left)
March 25, 2019
ATTACHMENT #5b
180 Market Street
South Burlington, VT
View of south facade from across Market Street (west corner)
March 25, 2019
Detail of South Porch Massing (Library, 2nd Floor)
ATTACHMENT #5c
180 Market Street
South Burlington, VT March 25, 2019
XXX X X XXXXXXXXXXX X X X X X X X X X X X XXXXXXXXXXXXXXX X X X X X X
TP/B5MARKET STREETS
C
H
O
O
L
D
R
I
V
E
W
A
Y
All reports, plans, specifications,computer files, field data, notes andother documents and instrumentsprepared by the Architect asinstruments of service shall remainthe property of the Architect. TheArchitect shall retain all common law,statutory and other reserved rights,including copyright thereto. AS NOTEDFOR CONSTRUCTION 3/29/19LIBRARY + SENIOR
CENTER + CITY HALL