HomeMy WebLinkAboutSD-19-07 - Supplemental - 1200 Airport Drive (24)P R O D U C T S P E C I F I C A T I O N S
CS102
Butyl Rubber Sealant For All Precast Structures;
Meets Specs.
1
P.O. Box 176, New Carlisle OH, 45344 • 937.845.8776 or 800.332.7325
FAX 937-845-3587 • www.conseal.com
APPLICATIONS
For self-sealing joints in: Manholes, Concrete Vaults, Septic Tanks, Concrete Pipe,
Box Culverts, Utility Vaults, Burial Vaults, and Vertical Panel Structures.
SEALING PROPERTIES
• Provides permanently flexible watertight joints.
• Low to high temperature workability: 30°F to 120°F (-1°C to 48°C)
• Rugged service temperature: -30°F to +200°F (-34°C to +93°C)
• Excellent chemical and mechanical adhesion to clean, dry surfaces.
• Sealed Joints will not shrink, harden or oxide upon aging.
• No priming normally necessary. When confronted with difficult installation
conditions, such as wet concrete or temperatures below 40°F (4°C), priming
the concrete will improve the bonding action. Consult Concrete Sealants for the
proper primer to meet your application.
HYDROSTATIC STRENGTH
ConSeal CS-102 meets the hydrostatic performance requirement as set forth
In ASTM C-990 section 10.1 (Performance requirement: 10psi for 10 minutes
in straight alignment – in plant, quality control test for joint materials.)
SPECIFICATIONS
ConSeal CS-102 meets or exceeds the requirements of Federal
Specification SS-S-210 (210-A), AASHTO M-198B, and ASTM C-990-91.
P R O D U C T S P E C I F I C A T I O N S
CS102
Butyl Rubber Sealant For All Precast Structures;
Meets Specs.
2
P.O. Box 176, New Carlisle OH, 45344 • 937.845.8776 or 800.332.7325
FAX 937-845-3587 • www.conseal.com
PHYSICAL PROPERTIES
Spec Required* CS 102
Hydrocarbon blend content % by
weight
ASTM D4 (mod.) 50% min. 51%
Inert mineral filler % by weight AASHTO T111 30% min. 35%
Volatile Matter % by weight ASTM D6 2% max. 1.2
Specific Gravity, 77°F ASTM D71 1.15-1.50 1.25
Ductility, 77°F ASTM D113 5.0 min. 10
Penetration, cone 77°F, 150 gm. 5
sec.
ASTM D217 50-100 55-60
Penetration, cone 32°F, 150 gm. 5
sec.
ASTM D217 40 mm 40-65
Flash Point, C.O.C., °F ASTM D92 350°F min. 450°F
Fire point, C.O.C., °F ASTM D92 375°F min. 475°F
IMMERSION TESTING
• 30-Day Immersion Testing: No visible deterioration when tested in 5% Caustic
Potash, 5% Hydrochloric Acid, 5% Sulfuric Acid, and 5% saturated Hydrogen
Sulfide. *
• One Year Immersion Testing: No visible deterioration when tested in 5%
Formaldehyde, 5% Formic Acid, 5% Sulfuric Acid, 5% Hydrochloric Acid, 5%
Sodium Hydroxide, 5% Hydrogen Sulfide and 5% Potassium Hydroxide.
• Requirements of ASTM C-990 Standard Specification for Joints for Concrete
Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants.
LIMITED WARRANTY
This information is presented in good faith, but we cannot anticipate all conditions under which this information and our products,
or the products of other manufacturers in combination with our products, may be used. We accept no responsibility for results
obtained by the application of this information or the safety and suitability of our products, either alone or in combination with
other products. Users are advised to make their own tests to determine the safety and suitability of each such product or product
combinations for their own purposes. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such
information for this own particular use. We sell this product without warranty, and buyers and users assume all responsibility and
liability for loss or damage arising from the handling and use of this product, whether used alone or in combination with other
products.