Loading...
HomeMy WebLinkAboutSD-96-0000 - Decision - 0155 Dorset StreetFINDINGS OF FACT & DECISION STATE OF VERMONT COUNTY OF CHITTENDEN S P- CITY OF SOUTH BURLINGTON Re: Findings of Fact, application of University Mall Realty Trust to amend a previously approved planned unit development consisting of a 525,100 square foot shopping center and drive -through bank facility. The amendment consists of the following: 1) construct a 111,392 square foot GLA addition to the main building, 2) construct a 990 space multi -level parking structure,and 3) acquire an 1.7 acre adjoining parcel, raze a single family dwelling and construct a 15,469 square foot automotive center, University Mall, 155 Dorset Street. On the 17th day of September, 1996, the South Burlington Planning Commission approved the preliminary plat application of University Mall Realty Trust under Section 203 of the South Burlington Subdivision Regulations based on the following findings: 1. This project consists of amending a previously approved planned unit development consisting of a 525,100 square foot shopping center and drive -through bank facility. The amendment consists of the following: 1) construct a 111,392 square foot GLA addition to the main building, 2) construct a 990 space multi -level parking structure, and 3) acquire a 1.7 acre adjoining parcel, raze a single family dwelling and construct a 15,469 square foot automotive service center, University Mall. The sketch plan was reviewed on 2/27/96. 2. This property located at 155 Dorset Street lies within the Cl and CO Districts. It is bounded on the north by a motel/restaurant, on the west by I-89, on the east by Dorset Street and on the south by single family residences. 3. Access/circulation: Access is currently provided by two (2) signalized curb cuts serving the shopping center and one (1) signalized curb cut serving the drive -through bank. Applicant is proposing a right -turn entrance only driveway just north of the Chittenden Bank. The applicant is attempting to design the drive so that it will comply with the requirement for a minimum 200 foot separation from signalized intersections (Section 26.103(d) of the zoning regulations). There may be a conflict with the overhead sign on Dorset Street. This drive should be reviewed by the City Engineer. 4. Section 12.403(b) requires a minimum separation of 400 feet between entrances to PUD's on either side of a public street. Both University Mall and 100 Dorset Street are PUD's. The Planning Commission has the authority to waive the 400 foot separation requirement between PUD entrances if the Planning Commission finds that limitations of the site cause unusual hardship. 5. In the parking structure, the furthest parking space from a stairwell is 190 feet. Several sources recommended no more than 200 feet. The furthest space from an elevator is 328 feet, sources recommend a maximum of 350 feet. 6. Coverage/setbacks: Building coverage is 29.9% (maximum allowed is 30%). This percentage does include the parking structure which should be included in the building coverage calculations. Overall coverage is 68.7% (maximum allowed is 70%). Front yard coverage will decrease from 39.5% to 37.5% (maximum allowed is 30%). Setback requirements are being met. 7. Landscaping: The minimum landscaping requirement, based on building costs, is $107,500 which is not being met. Proposed landscaping is $22,510 short of the minimum requirement. Staff recommended the following: 1) a row of trees along the U-Mall entrance road in front of the auto service center, 2) larger plant species throughout the site, in particular, proposed size of deciduous trees should be increased to a minimum 2J" - 3" caliper, and 3) a row of trees in the new curbed area along the western limit of the former Gleason parcel. 8. Parking: A total of 3383 parking spaces are required and 3160 spaces will be provided including 47 handicapped spaces (990 spaces in the parking structure and 2170 surface spaces). This represents a 223 space or 6.6% shortfall. Two (2) additional bike racks will be provided. 9. The City's required parking ratio is 5.5 spaces/1000 square feet gla. The applicant is proposing 5.2 spaces/1000 square feet gla. The Urban Land Institute recommends 5.0 spaces/1000 square feet gla. The International Council of Shopping Centers recommends 4.8 spaces/1000 square feet gla. 10. Sewer: The additional sewer allocation requested is 4798 gpd. The applicant will be required to pay the per gallon fee prior to permit. 11. C.O. District: The proposed addition no longer encroaches into the C.O. District along the I-89 r.o.w. as was the case at sketch plan review. The existing coverage along the interstate corridor in the C.O. District will decrease form 47.2% to 45.8%. 12. A portion of the automotive service center will encroach into the C.O. District wetland buffer area. The Planning Commission may allow this encroachment under Section 3.503 of the zoning regulations if the encroachment will not significantly affect adversely the attributes provided in Section 3.503(a)-(e). The Natural Resources Committee reviewed this project and opposes the W encroachment. The applicant has submitted a report addressing criteria (a)-(e) which indicates that these criteria will not be adversely affected. 13. Building height: The proposed department store addition will meet the 35 foot height limitation for a flat roofed structure. The stairwell and elevator areas for the proposed parking structure will exceed the 35 foot height limitation by four (4) feet. The pole lights on the top deck of the parking structure will exceed the 35 foot height limit by nine (9) feet. The proposed HVAC units will exceed the 35 foot height limitation by eight (8) feet. 14. The Planning Commission may allow an increase in height up to 45 feet if the Commission determines that a taller structure meets the following criteria contained in Section 25.113(b)(i) - (iii) of the zoning regulations: (i) Will utilize topography and will relate to other existing and proposed structures so as to be aesthetically compatible with the neighborhood; (ii) will not detract from scenic views of adjacent properties or public streets and walkways; and (iii) will allow retention of additional green space that will enhance the appearance of the developed property. 15. The applicant requested a height waiver for the rooftop apparatus, stairwell towers, and pole lights that will extend above the 35 foot height limit. The applicant has provided more green space on the site to comply with Section 25.113(b) (iii) of the zoning regulations to justify the increased height. The applicant proposed to increase the square footage of the parking garage in order to provide more parking spaces, and thereby turn some existing surface parking into green space. Areas to be converted to green space include providing more landscaped area along Dorset Street, more planting islands in the parking area near Coburn and Feeley, and provide a larger green belt along the interstate. 16. Traffic: The applicant submitted a traffic impact analysis which assesses the impact of the proposed development on the following intersections: o Dorset Street/Williston Road o Dorset Street/U-Mall north/Corporate Way o Dorset Street/U-Mall south o Dorset Street/Kennedy Drive o I-89 northbound off-ramp/Williston Road east o Dorset Street/100 Dorset Street/Chittenden Bank o Dorset Street/Dorset Square driveway o Patchen Road/Hinesburg Road/Williston Road 3 17. The study concluded that good levels of service are available at the two (2) intersections on Dorset Street where direct access is provided to University Mall. Acceptable performances were also noted at the other six (6) intersections that were included in the traffic impact study. 18. Lighting: Additional exterior lighting will consists of the following: --- 12 - 30 foot poles with 2-400 watt metal halide lamps with downcasting shielded fixtures. --- four (4) 30 foot poles with 1-400 watt metal halide lamps with downcasting shielded fixtures. The proposed pole lights exceed the 20 foot height limitation in the Performance Standards. Details of any building mounted lights should be approved by the City Planner prior to permit issuance. A point by point lighting plan should be submitted for the entire site. 19. Dumpsters: The dumpster storage area at the automotive service center will be screened. The applicant should show all dumpster/compactor storage areas on the property and show how they will be screened. 20. Other: --- the survey plats should show the Hedman property as to be merged with the rest of the U-Mall property. DECISION & CONDITIONS Based on the above Findings of Fact, the South Burlington Planning Commission approves the preliminary plat application of University Mall Realty Trust to amend a previously approved planned unit development consisting of a 525,100 square foot shopping center and drive -through bank facility. The amendment consists of the following: 1) construct a 111,392 square foot GLA addition to the main building, 2) construct a 990 space multi -level parking structure, and 3) acquire an 1.7 acre adjoining parcel, raze a single family dwelling and construct a 15,469 square foot automotive center, University Mall, 155 Dorset Street, as depicted on a 21 page set of plans, sheet 1 of 15 entitled "Overall Site Plan, Proposed Expansion University Mall, 155 Dorset Street, South Burlington," prepared by Pinkham Engineering Associates, Inc., dated 5/21/96, last revised 8/5/96 with the following stipulations: 1. All previous approvals and stipulations which are not superseded by this approval shall remain in effect. 4 2. Prior to final plat submittal, the plans shall be revised as follows: a) The landscape plans shall be revised to show the following: (i) a row of trees along the University Mall entrance road in front of the auto service center. (ii) a row of trees in the new curbed area along the western limit of the former Gleason parcel. (iii) larger plant species throughout the site, in particular, proposed size of deciduous trees shall be increased to a minimum 2j" - 3" caliper. b) Sheets Al - A4 shall be revised to show the new parking and circulation layout for the parking structure. c) The plans shall be revised to show all dumps ter/ compactor storage areas on the property properly screened with the type of screening noted on the plan. d) The survey plats shall show the Hedman property merged with the rest of the University Mall property. e) The plans shall show proposed location of relocated overhead signs, or new location of proposed entrance drive, whichever option is decided upon. f) Sheet 4 of 15 shall show a new location for any Dorset Street "Street trees" which may need to be moved in order to accommodate the new entrance drive. 3. Prior to issuance of a zoning permit, the applicant shall post a $107,500 landscape bond. The bond shall remain in effect for three (3) years to assure that the landscaping takes root and has a good chance of surviving. 4. The Planning Commission grants a sewer allocation of 4798 gpd. The applicant shall pay the per gallon fee prior to issuance of a permit. 5. All new exterior lighting shall consist of downcasting shielded fixtures so as not to cast light beyond the property line. Any changes in lighting shall be approved by the City Planner prior to installation. 6. The applicant shall submit a point by point lighting plan for the entire site with the revised final plat submittal. The lighting plan shall show that the maximum average lighting levels shall not exceed three (3) foot candles. 0 7. Pursuant to Section 26.256(b) of the zoning regulations, the Planning Commission approves a total of 3160 parking spaces which represents a 223 space or 6.6% shortfall. It is the Commission's opinion based on guidelines published by the Urban Land Institute and the International Council of Shopping Centers that the proposed number of spaces will be adequate. 8. Pursuant to Section 3.503 of the zoning regulations, the Planning Commission allows the encroachment of the automotive service center with associated parking into the C.O. District wetland buffer area. It is the Commission's opinion that the attributes provided in section 3.503(a)-(e) of the zoning regulations will not be adversely affected. 9. Trees shall be located outside of the relocated sewer main easement. 10. The sewer main maximum distance between manholes shall be no more than 300 feet. 11. The water department shall review the water main relocation prior to final plat. 12. Legal documents for the relocated sewer easement shall be submitted to the City Attorney for approval and shall be recorded in the South Burlington land records prior to issuance of a zoning permit. 13. Pursuant to Section 12.406(a) of the zoning regulations, the Planning Commission modifies the provisions of Section 12.403(b) requiring a minimum separation of 400 feet between PUD entrances due to limitations of the site. 14. Pursuant to Section 25.113(b) of the zoning regulations, the Commission approves an increase in height for the parking structure and building addition. For the parking structure, stairwell/elevator towers shall not exceed thirty-nine (39) feet and light poles shall not exceed forty-four (44) feet as shown on sheet A-5. For the building addition, the proposed HVAC units shall not exceed eight (8) feet in height for a total building height of forty-three (43) feet. It is the Commission's opinion that the criteria under Section 25.113(b)(i)-(iii) are being met. 15. Within three (3) months of occupancy of the expanded shopping center and automotive service center, the applicant shall submit to the City for review a signal timing/phasing study for all Dorset Street signals. The applicant shall be responsible for retiming the signals based on the recommendations of the study and as approved by the City. C. 16. For purposes of calculating required road impact fees under the South Burlington Impact Fee Ordinance, the Planning Commission estimates that the project will generate 379 additional P.M. peak hour trip ends. 17. As expressly represented by the applicant, there shall be no storage or display of tires, batteries or other merchandise outside of the auto service center building. 18. The revised final plat application shall be submitted within 12 months of the preliminary plat approval. 19. Within fifteen months after the opening of the new north entrance, the applicant shall file with the Commission a traffic safety study of the southbound segment of Dorset Street between Williston Road and the new north entrance of the Mall. The study shall provide accident data for the one-year period following the opening of the new north entrance and shall compare that data to accident data for preceding periods of the same segment, in its current configuration. 20. The Commission reserves jurisdiction over the project with respect to traffic safety issues; the Commission shall have the right to hold additional hearings and to impose additional approval conditions, including without limitation the right to close the most northern access to said planned unit development, if it determines that unsafe conditions have resulted from the project. 21. Upon expiration or termination of the applicant's lease with Chittenden Bank, or if an opportunity arises upon assignment or renewal or otherwise of said lease, the applicant shall implement certain changes in the access to the Chittenden property and U-Mall property as required by the Commission. Details of these changes shall be finalized at the final plat hearing. Prior to the final plat hearing,the applicant shall submit a copy of the lease to the City for review. 22. Prior to recording the final plat, the applicant shall record a "Notice of Condition" in the South Burlington Land records highlighting conditions under 19, 20, and 21. Chairman or Clerk South Burlington Planning Commission 4d (ozS .�- Date 7