Loading...
HomeMy WebLinkAboutSD-97-0000 - Decision - 0155 Dorset StreetFINDINGS OF FACT & DECISION STATE OF VERMONT S �i7- 0 000 COUNTY OF CHITTENDEN CITY OF SOUTH BURLINGTON Re: Findings of Fact, application of University Mall Realty Trust to amend a previously approved planned unit development consisting of a 525,100 square foot shopping center and drive -through bank facility. The amendment consists of the following: 1) construct a 111,392 square foot GLA addition to the main building, 2) construct a 990 space multi -level parking structure, and 3) acquire a 1.7 acre adjoining parcel, raze a single family dwelling and construct a 15,469 square foot automotive center, University Mall, 155 Dorset Street. On the 17th day of December, 1996, the South Burlington Planning Commission approved the request of University Mall Realty Trust for revised final plat approval under Section 204 of the South Burlington Subdivision Regulations based on the following findings: 1. This project consists of amending a previously approved planned unit development consisting of a 525,100 square foot shopping center and drive -through bank facility. The amendment consists of the following: 1) construct a 111,392 square foot GLA addition to the main building, 2) construct a 990 space multi -level parking structure,and 3) acquire an 1.7 acre adjoining parcel, raze a single family dwelling and construct a 15,469 square foot automotive center, University Mall. The preliminary plat was approved on 9/17/96. 2. This property located at 155 Dorset Street lies within the C1 and CO Districts. It is bounded on the north by a motel/restaurant, on the west by I-89, on the east by Dorset Street and on the south by single family residences. 3. Access/circulation: Access is currently provided by two (2) signalized curb cuts serving the shopping center and one (1) signalized curb cut serving the drive -through bank. Applicant is proposing a right -turn entrance only driveway just north of the Chittenden Bank. The applicant has designed this driveway to comply with the requirement for a minimum 200 foot separation from signalized intersections (Section 26.103(d) of the zoning regulations). 4. Section 12.403(b) of the zoning regulations requires a minimum separation of 400 feet between entrances to PUD's on either side of a public street. Both University Mall and 100 Dorset Street are PUD's. The Planning Commission has the authority to waive the 400 foot separation requirement between PUD entrances if the Planning Commission finds that limitations of the site cause unusual hardship. 5. In the parking structure, the furthest parking space from a stairwell is 190 feet. Several sources recommended no more than 200 feet. The furthest space from an elevator is 328 feet, sources recommend a maximum of 350 feet. 6. Coverage/setbacks: Building coverage is 29.9% (maximum allowed is 30%). This percentage includes the parking structure which should be included in the building coverage calculations. Overall coverage is 68.7% (maximum allowed is 70%). Front yard coverage will decrease from 39.5% to 36.2% (maximum allowed is 30%). Setback requirements are being met. 7. Landscaping: The minimum landscaping requirement, based on building costs, is $107,500 which is not being met. Proposed landscaping is $10,110 short of the minimum requirement. The applicant has complied with the following preliminary plat conditions: 1) plant a row of trees along the U-Mall entrance road in front of the auto service center, 2) use larger plant species throughout the site, in particular, proposed size of deciduous trees shall be increased to a minimum 22" - 3" caliper, and 3) plant a row of trees in the new curbed area along the western limit of the former Gleason parcel. Despite meeting these conditions the amount of landscaping proposed is still short $10,110 from the minimum landscaping requirement. The applicant proposed to plant $10,110 worth of landscaping in an off -site location approved by the City. 8. Parking: A total of 3383 parking spaces are required and 3160 spaces will be provided including 47 handicapped spaces (990 spaces in the parking structure and 2170 surface spaces). This represents a 223 space or 6.6% shortfall. The Planning Commission approved this parking waiver as part of the preliminary plat approval. Two (2) additional bike racks will be provided. 9. The City's required parking ratio is 5.5 spaces/1000 square feet gla. The applicant is proposing 5.2 spaces/1000 square feet gla. The Urban Land Institute recommends 5.0 spaces/1000 square feet gla. The International Council of Shopping Centers recommends 4.8 spaces/1000 square feet gla. 10. Sewer: The additional sewer allocation requested is being decreased from 4798 gpd to 4390 gpd. The applicant will be required to pay the per gallon fee prior to permit. 11. C.O. District: The proposed addition no longer encroaches into the C.O. District along the I-89 r.o.w. as was the case at sketch plan review. The existing coverage along the interstate corridor in the C.O. District will decrease form 47.2% to 45.8%. 2 12. A portion of the automotive service center will encroach into the C.O. District wetland buffer area. The Planning Commission may allow this encroachment under Section 3.503 of the zoning regulations if the encroachment will not significantly affect adversely the attributes provided in Section 3.503(a)-(e). The Natural Resources Committee reviewed this project and opposes the encroachment. The applicant submitted a report addressing criteria (a)-(e) which indicates that these criteria will not be adversely affected. The Planning Commission approved this encroachment as part of the preliminary plat approval. 13. Building height: The proposed department store addition will meet the 35 foot height limitation for a flat roofed structure. The stairwell and elevator areas for the proposed parking structure will exceed the 35 foot height limitation by four (4) feet. The pole lights on the top deck of the parking structure will exceed the 35 foot height limit by nine (9) feet. The proposed HVAC units will exceed the 35 foot height limitation by eight (8) feet. 14. The Planning Commission may allow an increase in height up to 45 feet if the Commission determines that a taller structure meets the following criteria contained in Section 25.113(b)(i) - (iii) of the zoning regulations: (i) Will utilize topography and will relate to other existing and proposed structures so as to be aesthetically compatible with the neighborhood; (ii) will not detract from scenic views of adjacent properties or public streets and walkways; and (iii) will allow retention of additional green space that will enhance the appearance of the developed property. 15. The applicant requested a height waiver for the rooftop apparatus, stairwell towers, and pole lights that will extend above the 35 foot height limit. The applicant provided more green space on the site to comply with Section 25.113(b) (iii) of the zoning regulations to justify the increased height. The applicant proposed to increase the square footage of the parking garage in order to provide more parking spaces, and thereby turn some existing surface parking into green space. Areas to be converted to green space include providing more landscaped area along Dorset Street, more planting islands in the parking area near Coburn and Feeley, and provide a larger green belt along the interstate. The Planning Commission approved the requested increase in height as part of the preliminary plat approval. 16. Traffic: The applicant submitted a traffic impact analysis which assesses the impact of the proposed development on the following intersections: 3 o Dorset Street/Williston Road o Dorset Street/U-Mall north/Corporate Way o Dorset Street/U-Mall south o Dorset Street/Kennedy Drive o I-89 northbound off-ramp/Williston Road east o Dorset Street/100 Dorset Street/Chittenden Bank o Dorset Street/Dorset Square driveway o Patchen Road/Hinesburg Road/Williston Road 17. The study concluded that good levels of service are available at the two (2) intersections on Dorset Street where direct access is provided to University Mall. Acceptable performances were also noted at the other six (6) intersections that were included in the traffic impact study. 18. The following conditions (#19,20 and 21) regarding traffic were required as part of preliminary plat approval: 19. Within fifteen months after the opening of the new north entrance, the applicant shall file with the Commission a traffic safety study of the southbound segment of Dorset Street between Williston Road and the new north entrance of the Mall. The study shall provide accident data for the one-year period following the opening of the new north entrance and shall compare that data to accident data for preceding periods of the same segment, in its current configuration. 20. The Commission reserves jurisdiction over the project with respect to traffic safety issues; the Commission shall have the right to hold additional hearings and to impose additional approval conditions, including without limitation the right to close the most northern access to said planned unit development, if it determines that unsafe conditions have resulted from the project. 21. Upon expiration or termination of the applicant's lease with Chittenden Bank, or if an opportunity arises upon assignment or renewal or otherwise of said lease, the applicant shall implement certain changes in the access to the Chittenden property and U-Mall property as required by the Commission. Details of these changes shall be finalized at the final plat hearing. Prior to the final plat hearing,the applicant shall submit a copy of the lease to the City for review. 22. Lighting: Additional exterior lighting will consist of the following: --- 12 - 30 foot poles with 2-400 watt metal halide lamps with downcasting shielded fixtures. --- four ( 4 ) 30 foot poles with 1-400 watt metal halide lamps with downcasting shielded fixtures. 4 23. The proposed pole lights exceed the 20 foot height limitation in the Performance Standards. These 30 foot poles were approved as part of the preliminary plat approval. Details of any building mounted lights should be approved by the City Planner prior to permit issuance. A point by point lighting plan was submitted for the entire site as required under the preliminary plat approval. This plan conforms with the requirement that the maximum illumination at ground level not be in excess of an average of three (3) foot candles. 24. Dumpsters: Screened dumpster storage areas will be provided on the entire site. 25. Other: As required by a condition attached to the preliminary plat approval, the applicant submitted a conceptual plan showing a future access through the Chittenden Bank property. Based on the lease agreement with the Chittenden Bank, the earliest the U-Mall could require this improvement to be made is in the year 2012, unless the bank defaults on the present lease before then. The Commission should include a condition similar to the preliminary plat condition which requires this plan to be implemented when the lease expires. Staff suggested that a final decision on whether or not to implement the plan be made by the Commission prior to it actually happening. The decision should be based on a final plan and full evaluation of the impacts. DECISION & CONDITIONS Based on the above Findings of Fact, the South Burlington Planning Commission approves the revised final plat application of University Mall Realty Trust to amend a previously approved planned unit development consisting of a 525,100 square foot shopping center and drive -through bank facility. The amendment consists of the following: 1) construct a 111,392 square foot GLA addition to the main building, 2) construct a 990 space multi -level parking structure,and 3) acquire a 1.7 acre adjoining parcel, raze a single family dwelling and construct a 15,469 square foot automotive center, University Mall, 155 Dorset Street, as depicted on an 18 page set of plans, sheet 1 of 15 entitled, "Overall Site Plan, Proposed Expansion University Mall, 155 Dorset Street, South Burlington," prepared by Pinkham Engineering Associates, Inc., dated 5/21/96, last revised 10/29/96 and a seven (7) page set of plans entitled, "University Mall Dorset Street South Burlington, Vermont, Grade Level Plan of Parking Structure," prepared by Sumner Schein Architects and Engineers, Inc, dated 10/3/96, with the following stipulations: 1. All previous approvals and stipulations which are not superseded by this approval shall remain in effect. k 2. Prior to issuance of a zoning permit, the applicant shall post a $107,500 landscape bond. The bond shall remain in effect for three (3) years to assure that the landscaping takes root and has a good chance of surviving. 3. The Planning Commission grants a sewer allocation of 4390 gpd. The applicant shall pay the per gallon fee prior to issuance of a permit. 4. All new exterior lighting shall consist of downcasting shielded fixtures so as not to cast light beyond the property line. Any changes in lighting shall be approved by the City Planner prior to installation. 5. Based upon the expressed representation of the applicant, the applicant shall plant $10,110 worth of landscaping in a public location determined appropriate by the City, in order to make up y�the shortfall in required landscaping. 6. Pursuant to Section 26.256(b) of the zoning regulations, the Planning Commission approves a total of 3160 parking spaces which represents a 223 space or 6.6% shortfall. It is the Commission's opinion based on guidelines published by the Urban Land Institute and the International Council of Shopping Centers that the proposed number of spaces will be adequate. 7. Pursuant to Section 3.503 of the zoning regulations, the Planning Commission allows the encroachment of the automotive service center with associated parking into the C.O. District wetland buffer area. It is the Commission's opinion that the attributes provided in section 3.503(a)-(e) of the zoning regulations will not be adversely affected. 8. Trees shall be located outside of the relocated sewer main easement. 9. The sewer main maximum distance between manholes shall be no more than 300 feet. 10. Legal documents for the relocated sewer easement and access drive easement shall be submitted to the City Attorney for approval and shall be recorded in the South Burlington land records prior to issuance of a zoning permit. 11. Pursuant to Section 12.406(a) of the zoning regulations, the Planning Commission modifies the provisions of Section 12.403(b) requiring a minimum separation of 400 feet between PUD entrances due to limitations of the site. 12. Pursuant to Section 25.113(b) of the zoning regulations, the Commission approves an increase in height for the parking structure and building addition. For the parking structure, 0 stairwell/elevator towers shall not exceed thirty-nine (39) feet and light poles shall not exceed forty-four (44) feet as shown on sheet A-5. For the building addition, the proposed HVAC units shall not exceed eight (8) feet in height for a total building height of forty-three (43) feet. It is the Commission's opinion that the criteria under Section 25.113(b)(i)-(iii) are being met. 13. Within six (6) months of occupancy of the expanded shopping center and automotive service center, the applicant shall submit to the City for review a signal timing/phasing study for all Dorset Street signals. The applicant shall be responsible for retiming the signals based on the recommendations of the study and as approved by the City. The methodology of the study shall be approved by the City prior to commencement of the study. 14. For purposes of calculating required road impact fees under the South Burlington Impact Fee Ordinance, the Planning Commission estimates that the project will generate 379 additional P.M. peak hour trip ends. 15. As expressly represented by the applicant, there shall be no storage or display of tires, batteries or other merchandise outside of the auto service center building. 16. Within fifteen months after the opening of the new north entrance, the applicant shall file with the Commission a traffic safety study of the southbound segment of Dorset Street between Williston Road and the new north entrance of the Mall. The study shall provide accident data for the one-year period following the opening of the new north entrance and shall compare that data to accident data for preceding periods of the same segment, in its current configuration. 17. The Commission reserves jurisdiction over the project with respect to traffic safety issues; the Commission shall have the right to hold additional hearings and to impose additional approval conditions, including without limitation the right to close the most northern access to said planned unit development, if it determines that unsafe conditions have resulted from the project. 18. Upon expiration or termination of the applicant's lease with Chittenden Bank, or if an opportunity arises upon assignment or renewal or otherwise of said lease, the applicant shall implement certain changes in the access to the Chittenden Bank property and U-Mall property as required by the Commission. Such changes may include closing the northernmost entrance - only access to the U- Mall property and constructing a joint access through the Chittenden Bank property, as shown on the plan entitled, "Conceptual Access Through Chittenden Bank," prepared by Pinkham Engineering Associates, Inc., and dated 10/24/96. Prior to 7 implementing said certain changes in access, the applicant shall return to the Commission for a final decision on the access changes, if any, to be implemented. 19. Prior to recording the final plat plans, the applicant shall record a "Notice of Condition" in the South Burlington Land records highlighting conditions under 16, 17, and 18, above. 20. Any change to the plat plans shall require approval by the South Burlington Planning Commission. 21. The final plat plans (i.e., two (2) survey plats and sheets 1 of 15, 2 of 15, 6 of 15 and 8 of 15) shall be recorded in the land l? records within 90 days or this approval is null and void. The C�plans shall be signed by the Planning Commission Chair or Clerk jr'yrior to recording. 22. The applicant shall install a physical barrier along the west side of the property to prevent the parking of vehicles on landscaped areas. The type of barrier shall be approved by the City Planner prior to installation. I Chairman or Clerk South Burlington Planning Commission Date ' 2 W, r i