Loading...
HomeMy WebLinkAboutSP-19-10 - Supplemental - 0321 Dorset Street (2)SSSSSSSSD D D D D D D D D D D D D D D D D S S S S S S S S WWWWDDDDG G G G G G G G G G G G G G G GGGGGGGGGGGGWWWWWWWWWWWWW W W W W W W W W W W W W W W W W W W UGUGUGUGUGUGUGT T T T T T T T T T T T T T T T T T T T T T T T UG UG UG UG UG UG UG UG UG UG UG UG UG UG UG UGUGUGUGUGUGUGUGSSSSSS T TTTTTTTTT T T T T T T UG UG UG UG UG UG UGUGUGUGUGUGUGUGTTTT T 309309 308 308308308308308 308307307307307 307 307307307307307307307307307307307 307 307306306 306306 306305305 305305305304304 304303303303302 302301301300300299299 307308GVGV50' CL A S S II WETLA N D B U F F E R 5.4'5.5'9.2'12.15' PROPOSED 6" SDR 35 PVC SEWER L=30' s =1/4"/FT = 0.0208 FT/FT MIN. PROPOSED 2-STORY BUILDING BASEMENT FFE = 298.1 1ST FLOOR FFE = 308.1 2ND FLOOR FFE = 319.18 WV 3.5'7.0' 9'18'24'10 8' S S ASSUMED WATER LINE LOCATION 6" ACASSUMED WATER LINE LOCATION 329 DORSET STREETFDFDRDRDRDRDRDRD FDRDFD RD RD FD FD FD FD FD FD FDFD FDFD FD 20'PAVED DRIVE PED. SIGNAL GRASS ISLAND GV GV PROJECT BENCHMARK "X" ON TOP OF BONET BOLT ELEV=310.08 CONNECT SEWER TO EXISTING MANHOLE SEE DETAIL R=306.95 i(W)=298.75 (EXISTING 8" PIPE) i(N)=298.78 (NEW 6" PIPE)BROOKWOOD DRIVEDORSET STREET CONCRETE225 DORSET STREET PAVEMENT SIDEWALK CONCRETE SIDEWALK MAJOR UNDERGROUND ELECTRIC UNDER SIDEWALK CB R=307.48 CB R=306.74 GARAGE 2 BROOKWOOD DRIVE CONCRETE PAD WITH ENCLOSED DUMPSTER 8 +++++++++++++++++++++++++++++++++++++++ ++++6" PERFORATED FOUNDATION DRAIN PROPOSED BIKE RACK PER DETAIL iOUT=299.45 SAWCUT PAVEMENT & REPLACE IN KIND 8" SEWER MAINSEWER/WATER CROSSING SEWER IE = 299.11 ASSUMED WATER IE = 300.61 CONTRACTOR TO VERIFY MINIMUM VERTICAL SEPARATION DISTANCE (SEE DETAIL) PROPOSED CONNECTION TO 3 PHASE POWER. CONTRACTOR TO COORDINATE WITH GREEN MOUNTAIN POWER 8' END CURB END CURB FULL HEIGHT CURB TO BE INSTALLED TO MATCH ADJACENT AFTER DRIVEWAY REMOVAL PER DEMO PLAN UP UP UP COORDINATE INSTALLATION OF CABINET WITH GREEN MOUNTAIN POWER G G 8.0' MIN.3.6'8.5'5.0'RD RDRDRDRDRDRDRD RD RD FD UPUPUPRD WATER SPIGOT FOR HOSE CONNECTION CONCRETE PATIO FLUSH WITH PAVEMENT PROPOSED 4' WIDE SIDEWALK PROPOSED 4' WIDE SIDEWALK PROPOSED 4' WIDE SIDEWALK DESIGNATED WALL MOUNTED ELECTRIC SERVICE LOCATION TC:307.96 BC:307.46 TC:307.96 BC:307.46 307.30 TC:307.36 BC:307.36 PROPOSED 3.5' WIDE SIDEWALKRDRDALL GRASSED AREAS TO HAVE MINIMUM 4" TOPSOIL 3.5'1.0'52.7'6.3' 0.3' 3.0' 5.4'3.5'71.6' “ “ “ “ PROPOSED 4' WIDE SIDEWALK PROPOSED 4' WIDE SIDEWALK FD FD FD FD FD FD LOCATION OF OUTLET FOR EV CHARGING TC:307.86 BC:307.36 6' HIGH WHITE VINYL PRIVACY FENCE PER DETAIL ON LANDSCAPE PLAN PROPOSED 7' WIDE SIDEWALK TREE PIT FENCE (TYPICAL) PER DETAIL ON LANDSCAPE PLAN WWWW3/4" COPPER WATER LINEFMFMFMFMSNOW STORAGE AREA ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎGMP TRANSFORMER PAD EXISTING MAPLE TO REMAIN PROPOSED RAISED BED (TYP) 6' HIGH WHITE VINYL FENCE TO BE REMOVABLE 8.75'18'Sheet Title Project Title Use of These Drawings Project Reference:Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEER ING SURVEY No. 8917 CIVILJENNIFER A NN DES A U T ELSSTATE O F VER M ONTPROF E SSIONA L E N G INEERL I C E N S E D Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory DXWKRULWLHV¬ They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive SURSHUW\¬ Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. P L A N N I N G E N V I R O N M E N T A L 0 Feet Graphic Scale 10 10 20 30 40 1 08/08/18 JADPer Town Comments ----(321) 0570-00321 (325) 0570-000325 ----C2-02 1" = 10' 17-119 RMP JAD JPP 348 PROJECT LOCATION NOTES: 1.THE PURPOSE OF THIS PLAN IS TO DEPICT THE REDEVELOPMENT OF 321 DORSET STREET. THE TWO EXISTING RANCH STYLE BUILDINGS WILL BE DEMOLISHED AND REPLACED WITH ONE TWO STORY BUILDING WITH MEDICAL OFFICE SPACE ON THE FIRST FLOOR AND SIX ONE BEDROOM RESIDENTIAL UNITS ABOVE. 2.OWNER OF RECORD: MITCHWARTZ PROPERTIES LLC 3.E-911 ADDRESS: 321 DORSET STREET 4.ZONING DISTRICT: FBC T4 5.LOT SIZE = 0.34 +/- ACRE Site Plan 06/01/2018 MITCHWARTZ PROPERTIES, LLC 321 Dorset Street South Burlington, Vermont OPEN SPACE : 6% OF NON-RESIDENTIAL GROSS FLOOR AREA (GFA) + 100 SF/ RESIDENTIAL UNIT TOTAL OPEN SPACE REQUIRED: (6% X 7,665 S.F. GFA) + (100 SF/RES. UNIT X 6 UNITS) = 1,060 S.F. OPEN SPACE PROVIDED = 1,088 S.F. PARKING: 2 SPACES MAXIMUM/RESIDENTIAL UNIT + 2 SPACES MINIMUM/1,000 SF OF NON-RESIDENTIAL GFA 2 SPACES MIN. / 1,000 SF X 7,665 SF = 16 NON-RES SPACES MINIMUM 2 SPACES MAX. / RES. UNIT = 12 RESIDENTIAL SPACES MAXIMUM PARKING SPACES PROVIDED = 18 CONTRACTOR NOTES: 1.CONTRACTOR TO FIELD VERIFY UTILITY LOCATIONS PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 2.CONTRACTOR TO NOTIFY UTILITY AUTHORITIES (SOUTH BURLINGTON, CWD, VT GAS, GMP) PRIOR TO COMMENCING CONSTRUCTION AND CONNECTIONS TO UTILITIES. 3.CONTRACTOR TO COORDINATE CABLE AND TELEPHONE LINE SERVICES DIRECTLY WITH PROVIDERS. NOTE THAT UTILITY METER SHALL NOT BE LOCATED ON THE FACADE OF THE BUILDINGS PARALLEL WITH THE ADJACENT STREETS PER CITY OF SO. BURLINGTON LDR 8.06 (G). 4.ANY EXCAVATION WITHIN THE MUNICIPAL R.O.W. IS SUBJECT TO A RIGHT-OF-WAY PERMIT ISSUED BY THE DEPARTMENT OF PUBLIC WORKS. 5.CONTRACTOR TO FOLLOW LOW RISK EROSION CONTROL HANDBOOK INCLUDING A STABILIZED CONSTRUCTION ENTRANCE. BASIS OF DESIGN : WASTEWATER 6 STAFF (DOCTOR'S OFFICE) X 35 GPD/STAFF = 210 GPD 45 PATIENTS (DOCTOR'S OFFICE) X 10 GPD/PATIENT = 450 GPD 6 BEDROOMS (APARTMENTS) X 140 GPD/BEDROOM = 840 GPD TOTAL = 1500 GPD 80% WITH REDUCTION FOR MUNICIPAL CONNECTION = 1200 GPD WATER 6 STAFF (DOCTOR'S OFFICE) X 35 GPD/STAFF = 210 GPD 45 PATIENTS (DOCTOR'S OFFICE) X 10 GPD/PATIENT = 450 GPD 6 BEDROOMS (APARTMENTS) X 150 GPD/BEDROOM = 900 GPD TOTAL = 1560 GPD 90% WITH REDUCTION FOR LOW FLOW FIXTURES = 1404 GPD 2 08/23/18 JADBike Rack 3 09/04/18 JADPer Town Comments 4 10/12/18 CMJGroundwater Pump Station 5 04/09/18 CMJGroundwater Pump Station 6 04/19/19 JADRevision to Incorporate GMP's Transformer 7 04/22/19 JADRevision to Incorporate GMP's Transformer 8 04/26/19 JADRevision to Parking Width & Open Space Area