Loading...
HomeMy WebLinkAboutZP-24-366 - 0125 Aurora Road 11/6/2024A.O. Note: This should be 125 Aurora Road. See attached emailxxxxxxx ZP-24-366 10/22/2024 SEQNR #SD-18-28 1,568.00 1/2 of duplex 11/26/2018 11/06/2024 11/22/2024 11/05/2025 (Acting) 1 Betsy Brown From:Brad Dousevicz <dousevicz@gmail.com> Sent:Tuesday, November 5, 2024 1:16 PM To:Betsy Brown Subject:EXTERNAL: Re: 125/127 Aurora Applications This message has originated from an External Source. Please use proper judgment and caution when opening attachments, clicking links, or responding to this email. Yes sorry those should be Aurora. On Tue, Nov 5, 2024 at 12:59 PM Betsy Brown <bbrown@southburlingtonvt.gov> wrote: Hi Brad, The applications for 125 & 127 Aurora Road say Orleans Road on them. For the record, can you confirm that this is a type and that the permits are for Aurora Road? Thanks, -Betsy Betsy Brown Planning & Zoning Assistant Acting Administrative Officer City of South Burlington 180 Market Street South Burlington, VT 05403 (802) 846-4106 www.sbvt.gov [sbvt.gov] Property Owners Name:JJJ South Burlington Property Location:125 Aurora Road Amount:22,100.61 Payment Type:chks #918 & 922 Date:10/22/2024 CodeZoning Permit (New Residential)ZP-24-366 zp Recording fee 13.00$ plus 2700 0.45$ per sq. ft. 1,215.00$ plus 1200 0.20$ per sq. ft. 240.00$ plus 2 50.00$ per bay 100.00$ plus After-the fact of 50% [no NOV] or 100% [NOV] -$ Zoning Permit Total 1,568.00$ Sewer Allocation Fee WWA-24-155 #204 234.15 g.p.d x 16.17$ 3,786.21$ Bartlett Bay Airport Parkway Impact Fee Administration Fee #248 100.00$ per application 100.00$ School Impact Fee #222S 4 bedrroms 12,353.51$ Recreation Impact Fee #220 1,665.08$ per unit 1,665.08$ South Village Recreation Impact Fee #243 per unit -$ Road Impact Fee #221 641.66$ per unit 641.66$ Cider Mill Impact Fee* *See #SD-18-28 #213 1,000.00$ per unit 1,000.00$ Fire Impact Fee #203 -$ Police Impact Fee #222 496.45$ per unit 496.45$ Dorset Street Waterline Fee #230 $426.70 per unit 426.70$ Sewer Connection Inspection WWC-24-59 ww 63.00$ per connection 63.00$ Total (Impact Fees + Permit) 22,100.61$ Planning & Zoning Invoice Residential Impact & Permit Fees garage bay(s) at Amount Due sq. ft building at sq. ft unfinished basement at 45 ' - 0 " 2' - 0 " 18' - 6 1/2"21' - 5 1/2"21' - 5 1/2"18' - 6 1/2" 19' - 0"20' - 7"10"20' - 7"19' - 0" 12 ' - 6 " 5' - 0 " 2' - 0 " 22 ' - 0 " 25 ' - 0 " 2' - 0 " 10' - 0"8' - 4"21' - 8"21' - 8"8' - 4"10' - 0" GARAGE SLAB ON GRADE OPEN BASEMENT UNFINISHED SPACE GARAGE SLAB ON GRADE OPEN BASEMENT UNFINISHED SPACE PORCH ABOVE PORCH ABOVE 7'-11"x7'-6" MECHANICAL ROOM W/ 2x4 WALLS & DOOR (4) PRECAST PORCH PIERS (4) PRECAST PORCH PIERS UTILITIES COMING FROM STREET IN THIS APPROX. LOCATION UTILITIES COMING FROM STREET IN THIS APPROX. LOCATION CONSTRUCTION NOTES: 10" THICK x 20" WIDE TYPICAL FOOTING 8" THICK, 9'-2" TALL FOUNDATION WALLS BASEMENT TO HAVE TWO MECHANICAL ROOMS AS SHOWN - GWB FINISH ON EXTERIOR OF MECHANICAL ROOM WALLS BASEMENT WALL INSULATION = R21 3" POLYISO INSULATION BOARD (SAME AS STREAMSIDE) (1) BILCO EGRESS WELL PER UNIT BASEMENT IS UNFINISHED BASEMENT STAIRS ARE UNFINISHED RADON PIPE UNDERSLAB BY PLUMBING TRADE ALL ESCAPE WINDOW SILLS SHALL NOT BE MORE THAN 44" 3' - 5"14' - 3" 8' - 0 " 45 ' - 0 " 8' - 0 " CONTRACTOR TO VERIFY STAIRS UP 16R @ 7.28" 15T @ 10" 19' - 0" 8' - 0 " 19' - 0" 17' - 0"17' - 0" 2' - 0 " DECK ABOVE (AT GRADE) DECK ABOVE (AT GRADE) 9' - 5 1/2"12' - 0"12' - 0"9' - 5 1/2" EGRESS4646 EGRESS46468' - 0 " GARAGE DOOR CUTS ADDITIONAL 1-1/2" ON EA. SIDE FOR FRAMING 2' - 7"16' - 3"2' - 10"2' - 7"16' - 3"2' - 10" ROUGH-IN PLUMBING ONLY UNLESS SPECIFIED OTHERWISE 7'-11"x7'-6" MECHANICAL ROOM W/ 2x4 WALLS & DOOR 3' - 5"14' - 3" CONTRACTOR TO VERIFY STAIRS UP 16R @ 7.28" 15T @ 10" ROUGH-IN PLUMBING ONLY UNLESS SPECIFIED OTHERWISE WINDOW WELL BY CONTRACTOR PER NFPA 101 SEC. 24.2.2.3.3 (4) EGRESS WINDOW SILL(S) NOT TO BE HIGHER THAN 44" ABOVE FLOOR (TYP.) WINDOW WELL BY CONTRACTOR PER NFPA 101 SEC. 24.2.2.3.3 (4) EGRESS WINDOW SILL(S) NOT TO BE HIGHER THAN 44" ABOVE FLOOR (TYP.) SCALE: DATE: DRAWN BY: CHECKED BY: PROJECT: SHEET TITLE: TH I S D R A W I N G I S T H E PR O P E R T Y O F G 4 D E S I G N ST U D I O S , L L C A N D I S N O T T O BE C O P I E D , R E P R O D U C E D , O R TH E C O N T E N T T H E R E O F U S E D , IN W H O L E O R I N P A R T , WI T H O U T T H E P R I O R W R I T T E N CO N S E N T O F S T E V E G U I L D 1/4" = 1'-0" 9/ 2 6 / 2 0 2 4 1 1 : 0 0 : 5 7 A M A-1 BASEMENT PLAN DO U S E V I C Z 12 5 , 1 2 7 A U R O R A G4 G4 9/24/2024 EDGE WD. SO U T H B U R L I N G T O N , V E R M O N T OPTION #1B 1/4" = 1'-0"1 BASEMENT PLAN DINING HARDWOOD KITCHEN HARDWOOD LIVING HARDWOOD MASTER BATH TILE PA N T R Y CL O S E T ENTRY HARDWOOD COVERED PORCH COMPOSITE DECKING OPEN DECK COMPOSITE DECKING DINING HARDWOOD KITCHEN HARDWOOD LIVING HARDWOOD MASTER BATH TILE PA N T R Y CL O S E T ENTRY HARDWOOD COVERED PORCH COMPOSITE DECKING OPEN DECK COMPOSITE DECKING DH 3 0 6 0 CS F 4 0 4 6 DH 3 0 6 0 DH 3 0 6 0 30 6 8 3068 2668 3068 CS3040DH3060-2W DH 3 0 6 0 CS F 4 0 4 6 DH 3 0 6 0 DH 3 0 6 0 3068 2668 50 6 8 3068 CS3040 DH3060-2W 30 6 8 16' x 8' O.H.D.16' x 8' O.H.D. 17' - 0"46' - 0"17' - 0" 4' - 1 3/8"9 1/4"4' - 1 3/8"5' - 0"8' - 6 1/2"5' - 0" 80' - 0" DH3060-2W DH3060-2W 6' - 5 1 / 2 " 2' - 0 " 8' - 0 " 3' - 8 " 5' - 1 1 " 3' - 3 " 22 ' - 6 1 / 2 " TWO CAR GARAGE TWO CAR GARAGE 2' - 4 1/2"3' - 8"3' - 8" CL S T . W.I.C. CARPET MUDROOM TILE BENCH HALLWAY TILE 21 0 6 8 2668 30 6 8 2668 3068 CL S T . W.I.C. CARPET MUDROOM TILE BENCH HALLWAY TILE 21 0 6 8 2668 30 6 8 2668 3068 30 6 8 30 6 8 VSB30 VSB30GAS & ELEC. WASH/DRY TILE GAS & ELEC. WASH/DRY TILE CONSTRUCTION NOTES: 2x6 EXTERIOR WALLS R12 ZIP SHEATHING TO COMPLY w/ VT ENERGY CODE R21 EXTERIOR WALL INSULATION R21 CLOSED CELL FOAM AT BOX PLATES R60 ATTIC INSULATION R30 FLOOR INSULATION SOUND PROOFING ACOUSTICAL INSULATION AT WALL BETWEEN DUPLEX UNITS FLOOR FINISHES AS INDICATED ON PLANS DOOR AND WINDOW SIZES AS INDICATED ON PLANS KITCHEN APPLIANCE PACKAGE WILL BE SAME AS TYPICAL STREAMSIDE PACKAGE GAS CONNECTION FOR WASHER GAS CONNECTION FOR RANGE/OVEN GARAGE DOOR TYPICAL OF STREAMSIDE HARVEY WINDOWS WITH BLACK EXTERIOR, WHITE INTERIOR TYPICAL OF STREAMSIDE EXTERIOR DOORS ARE THERMATRU FIBERGLASS, TYPICAL OF STREAMSIDE CLASSIC GRANITE COUNTER-TOPS, TYPICAL OF STREAMSIDE KITCHEN CABINETS TYPICAL OF STREAMSIDE (MID CONTIGENT SIGNATURE SERIES) CULTURED MARBLE TOPS FOR BATHROOM VANITIES 1/2 BATH TO HAVE BATH VANITY MASTER BATH SHOWER TO HAVE FIBERGLASS SHOWER PAN, TILE SURROUND, GLASS DOORS, TYPICAL OF STREAMSIDE ALL CLOSETS TO HAVE WHITE WIRE SHELVING LIGHT FIXTURES TYPICAL OF STREAMSIDE MECHANICAL SYSTEM TYPICAL OF STREAMSIDE (YORK LX FURNACE, YORK CONDENSER, BRADFORD 50 GAL WATER HEATER) PLUMBING FIXTURES TYPICAL OF STREAMSIDE WINDOW & DOOR TAGS AS FOLLOWED: CS MEANS CASEMENT CSF MEANS FRENCH CASEMENT DH MEANS DOUBLE-HUNG S OR SL MEANS SLIDER 4046 MEANS 4'-0" WIDE by 4'-6" HEIGHT 8' - 0 " 3' - 0 " 10 ' - 0 " 14 ' - 0 " 11 ' - 6 " 6' - 6 " 8' - 0 " 8' - 0 " 3' - 0 " 10 ' - 0 " 14 ' - 0 " 11 ' - 6 " 6' - 6 " 8' - 0 " 50 6 8 S6068DH3060S6068DH3060 5' - 0"8' - 6 1/2"5' - 0"9' - 5 1/2"7' - 6"9' - 5 1/2"7' - 6" 6' - 5 1 / 2 " 2' - 0 " 8' - 0 " 5' - 1 1 " 3' - 3 " 22 ' - 6 1 / 2 " 2' - 4 1/2"3' - 8"20' - 7 3/8"9 1/4"20' - 7 3/8" 22 ' - 0 " 22 ' - 0 " 5' - 0"5' - 0"8' - 6 1/2"5' - 0"5' - 0"8' - 6 1/2" 5' - 6"3' - 8" 3' - 9"4' - 5 3/8"2' - 1" 11 ' - 1 1 1 / 2 " 5' - 6"3' - 8" 3' - 9"4' - 5 3/8" 11 ' - 1 1 1 / 2 " 2' - 1" 3' - 6 " 6' - 0 " 14 ' - 5 1 / 2 " 1/2 BATH TILE 3' - 6 " 6' - 0 " 14 ' - 5 1 / 2 " 1/2 BATH TILE 6' - 0 " 6' - 0 " 45 ' - 0 " CONTRACTOR TO VERIFY STAIRS UP 16R @ 7.57" 15T @ 10" CONTRACTOR TO VERIFY STAIRS UP 16R @ 7.57" 15T @ 10" 11' - 11"11' - 11" REQUIREMENTS PER SO. BURLINGTON FIRE MARSHALL 1. ANY FIRE, SMOKE BARRIERS, AND INTERIOR FINISHES WILL BE MAINTAINED, RECONSTRUCTED OR INSTALLED PER IBC AND NFPA REQUIREMENTS FOR THE OCCUPANY USE GROUP (NFPA 1). ALL PENETRATIONS BETWEEN FLOORS, ATTICS, AND /OR BASEMENTS SHALL BE FIRE STOPPED WITH FIRE/SMOKE PENETRATION CAULKING/SEALANTS SHALL BE RED IN COLOR FOR EASE OF IDENTIFICATION. ALL FIRE WALLS AND SMOKE BARRIERS SHALL BE CLEARLY STENCILED ABOVE THE CEILING PURSUANT TO IBC AND NFPA REQUIREMENTS. FOAM FIRE BLOCKING IS PROHIBITED 2. IF THE BASEMENT IS TO BE FINISHED, THE FURNACE AREA SHALL BE PROTECTED BY SEPARATE FIRE RATED COMPARTMENT (CEILING INCLUDED), OR BY LIMITED AREA SPRINKLER HEAD OVER/BY APPLIANCE, INSTALLED BY LICENSED PROFESSIONAL 3. THE BACKSIDE OF BASEMENT STAIRS AND LANDING(S) SHALL BE PROTECTED BY 5/8" SHEETROCK AND TAPED WITH A MINIMUM OF ONE COAT. 4. ALL ESCAPE WINDOW SILLS SHALL NOT BE MORE THAN 44" 5. PHOTO SMOKE/CO2 DETECTORS SHALL BE INSTALLED PER SBFPFSO, AND BE HARD WIRED, INTERCONNECTED TO ALL DETECTION WITHIN THE DWELLING UNIT 6. SERVICE DOORS FROM DWELLING TO GARAGE SHALL BE A MINIMUM OF A 45 MINUTE FIRE-RATED DOOR WITH A SELF-CLOSING/LATCHING DOOR LEAF 7. ALL ELECTRICAL REQUIRES A SEPERATE SUB TRADE WORK PERMIT/WORK NOTICE ISSUED BY THE SBFD ELECTRICAL INSPECTOR. ALL ELECTRICAL TRADES PERSONS SHALL HAVE VALID STATE ELECTRICAL LICENSES 8. ALL PLUMBING WORK REQUIRES A SEPERATE SUB TRADE WORK PERMIT/WORK NOTICE ISSUED BY DFS-WILLISTON. ALL PLUMBING TRADES PERSONS SHALL HAVE VALID STATE PLUMBING LICENSES 9. CONSTRUCTION DUMPSTER(S) SHALL BE LOCATED A MINIMUM OF 10 FEET FROM ANY COMBUSTIBLE OR OPEN SURFACE OF THE BUILDING. DUMPSTERS SHALL NOT OBSTRUCT EGRESS 10. NO SMOKING IS ALLOWED WITHIN 10 FEET OF THE BUILDING 11. THE BUILDING SHALL BE IN COMPLIANCE WITH NFPA 241 DURING CONSTRUCTION 12. THE BUILDING SHALL ADDRESS NUMBERS PLACED IN A POSITION TO BE PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THE NUMBERS SHALL BE IN HIGH CONTRAST WITH THEIR BACKGROUND PER NFPA 1 (2015) AND THE CITY ORDINANCES 13. A 1A-10BC FIRE EXTINGUISHER SHALL BE INSTALLED IN THE KITCHEN IN PLAIN VIEW. UL# V324 1HR FIRE RATED WALL ASSEMBLY MASTER BEDROOM HARDWOOD MASTER BEDROOM HARDWOOD HW STAIRS HW STAIRS FI R E P L A C E 5' - 0 " 5' - 6 " FI R E P L A C E 5' - 0 " 5' - 6 " 3' - 8 " 1' - 6"1' - 6" 19' - 0"21' - 0"21' - 0"19' - 0" "TRADITIONAL MANTLE" PER OWNER FIRST FLOOR SQFT 1,354 w/o garage FIRST FLOOR SQFT 1,354 w/o garage SCALE: DATE: DRAWN BY: CHECKED BY: PROJECT: SHEET TITLE: TH I S D R A W I N G I S T H E PR O P E R T Y O F G 4 D E S I G N ST U D I O S , L L C A N D I S N O T T O BE C O P I E D , R E P R O D U C E D , O R TH E C O N T E N T T H E R E O F U S E D , IN W H O L E O R I N P A R T , WI T H O U T T H E P R I O R W R I T T E N CO N S E N T O F S T E V E G U I L D 1/4" = 1'-0" 9/ 2 6 / 2 0 2 4 1 1 : 0 1 : 0 1 A M A-2 FIRST FLOOR PLAN DO U S E V I C Z 12 5 , 1 2 7 A U R O R A G4 G4 9/24/2024 EDGE WD. SO U T H B U R L I N G T O N , V E R M O N T OPTION #1B 1/4" = 1'-0"1 FIRST FLOOR PLAN BEDROOM #3 CARPET W.I.C. CARPET HALLWAY HARDWOOD BEDROOM #1 CARPET BEDROOM #2 CARPET W.I.C. CARPET ATTIC BEDROOM #3 CARPET W.I.C. CARPET HALLWAY HARDWOOD BEDROOM #1 CARPET BEDROOM #2 CARPETW.I.C. CARPET 15 ' - 3 " 2' - 0 " 15 ' - 3 " 14' - 7"4' - 1 1/2" 5' - 0"9' - 0"5' - 0"6' - 0"12' - 0"6' - 0"12' - 0"6' - 0"5' - 0"9' - 0"5' - 0" 80' - 0" 43 ' - 0 " 2668 21 0 6 8 3068 DH3050-2W 30 6 8 3068 3068 DH3050-2W 2668 DH3050-2W 3068 3068 DH3050-2W DH3050-2W DH3050-2W 11 ' - 1 1 " CS 3 0 3 0 30 6 8 3068 CS 3 0 3 0 INSULATED SOUND PROOFING ACCOUSTICAL INSULATION (BASE SCOPE) SOUND PROOFING ACCOUSTICAL INSULATION (BASE SCOPE) CONSTRUCTION NOTES: BLUE SHOWS EXTENT OF EXTERIOR ENVELOPE FOR BASE SCOPE GREEN SHOWS THE ADD- ALTERNATIVE INSULATION SCOPE THE BONUS ROOM ITEMS SHOULD BE BROKEN OUT IN SUBCONTRACTOR'S PROPOSAL THE DOORS INTO THE BONUS ROOM AND THE BONUS ROOM CLOSET DOOR SHOULD BE INSULATED AS THESE ARE EXTERIOR ENVELOPE WHITE WIRE SHELVING IN ALL CLOSETS FIBERGLASS TUB/SHOWER COMBO 15 ' - 3 " 13' - 6 1/2"5' - 2" 15 ' - 3 " 2' - 0 " 15 ' - 3 " 14' - 7" 43 ' - 0 " 11 ' - 1 1 " 24 ' - 8 1 / 4 " 18 ' - 3 3 / 4 " 24 ' - 8 1 / 4 " 18 ' - 3 3 / 4 " 14' - 7"14' - 7" 13' - 6 1/2"5' - 2" 15 ' - 3 " 3' - 8" 3' - 8 " 3' - 3 1 / 2 " 5' - 4 1 / 2 " 6' - 0 " W.I.C. CARPET 3' - 8" 15 ' - 3 " 3' - 8" 3' - 8 " 3' - 3 1 / 2 " 5' - 4 1 / 2 " 6' - 0 " W.I.C. CARPET 21' - 0"21' - 0" REQUIREMENTS PER SO. BURLINGTON FIRE MARSHALL 1. ANY FIRE, SMOKE BARRIERS, AND INTERIOR FINISHES WILL BE MAINTAINED, RECONSTRUCTED OR INSTALLED PER IBC AND NFPA REQUIREMENTS FOR THE OCCUPANY USE GROUP (NFPA 1). ALL PENETRATIONS BETWEEN FLOORS, ATTICS, AND /OR BASEMENTS SHALL BE FIRE STOPPED WITH FIRE/SMOKE PENETRATION CAULKING/SEALANTS SHALL BE RED IN COLOR FOR EASE OF IDENTIFICATION. ALL FIRE WALLS AND SMOKE BARRIERS SHALL BE CLEARLY STENCILED ABOVE THE CEILING PURSUANT TO IBC AND NFPA REQUIREMENTS. FOAM FIRE BLOCKING IS PROHIBITED 2. IF THE BASEMENT IS TO BE FINISHED, THE FURNACE AREA SHALL BE PROTECTED BY SEPARATE FIRE RATED COMPARTMENT (CEILING INCLUDED), OR BY LIMITED AREA SPRINKLER HEAD OVER/BY APPLIANCE, INSTALLED BY LICENSED PROFESSIONAL 3. THE BACKSIDE OF BASEMENT STAIRS AND LANDING(S) SHALL BE PROTECTED BY 5/8" SHEETROCK AND TAPED WITH A MINIMUM OF ONE COAT. 4. ALL ESCAPE WINDOW SILLS SHALL NOT BE MORE THAN 44" 5. PHOTO SMOKE/CO2 DETECTORS SHALL BE INSTALLED PER SBFPFSO, AND BE HARD WIRED, INTERCONNECTED TO ALL DETECTION WITHIN THE DWELLING UNIT 6. SERVICE DOORS FROM DWELLING TO GARAGE SHALL BE A MINIMUM OF A 45 MINUTE FIRE-RATED DOOR WITH A SELF-CLOSING/LATCHING DOOR LEAF 7. ALL ELECTRICAL REQUIRES A SEPERATE SUB TRADE WORK PERMIT/WORK NOTICE ISSUED BY THE SBFD ELECTRICAL INSPECTOR. ALL ELECTRICAL TRADES PERSONS SHALL HAVE VALID STATE ELECTRICAL LICENSES 8. ALL PLUMBING WORK REQUIRES A SEPERATE SUB TRADE WORK PERMIT/WORK NOTICE ISSUED BY DFS-WILLISTON. ALL PLUMBING TRADES PERSONS SHALL HAVE VALID STATE PLUMBING LICENSES 9. CONSTRUCTION DUMPSTER(S) SHALL BE LOCATED A MINIMUM OF 10 FEET FROM ANY COMBUSTIBLE OR OPEN SURFACE OF THE BUILDING. DUMPSTERS SHALL NOT OBSTRUCT EGRESS 10. NO SMOKING IS ALLOWED WITHIN 10 FEET OF THE BUILDING 11. THE BUILDING SHALL BE IN COMPLIANCE WITH NFPA 241 DURING CONSTRUCTION 12. THE BUILDING SHALL ADDRESS NUMBERS PLACED IN A POSITION TO BE PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THE NUMBERS SHALL BE IN HIGH CONTRAST WITH THEIR BACKGROUND PER NFPA 1 (2015) AND THE CITY ORDINANCES 13. A 1A-10BC FIRE EXTINGUISHER SHALL BE INSTALLED IN THE KITCHEN IN PLAIN VIEW. LINEN CL. W.I.C. CARPET LINEN CL. 2' - 0 " 11 ' - 6 " 7' - 0 " 11 ' - 9 1 / 2 " 2' - 0 " 11 ' - 6 " 7' - 0 " 11 ' - 9 1 / 2 " W.I.C. CARPET PK T 2 6 6 8 BATHROOM TILE 5' T / S U N I T PK T 2 6 6 8 BATHROOM TILE 5' T / S U N I T 4068 6' - 2 " 5' - 5 1 / 2 " 3' - 7 1/2"3' - 8" 5' - 1 " 4' - 2 " 6' - 6 1/2" 2' - 1 " 6' - 2 " 5' - 5 1 / 2 " 3' - 7 1/2" 5' - 1 " 4' - 2 " 6' - 6 1/2" 2' - 1 " 4' - 1 1/2" 9' - 6"9' - 6"42' - 0"9' - 6"9' - 6" 3068 26 6 8 3068 26 6 8 3068 13 ' - 6 " 13 ' - 6 " 6' - 2"14' - 6 1/2"14' - 6 1/2"6' - 2" INSULATED 15 ' - 3 " 4068 30 6 8 30 6 8 6' - 0"6' - 0"6' - 0"6' - 0" SECOND FLOOR SQFT 1,337 SQFT w/o stair opening SECOND FLOOR SQFT 1,337 SQFT w/o stair opening SCALE: DATE: DRAWN BY: CHECKED BY: PROJECT: SHEET TITLE: TH I S D R A W I N G I S T H E PR O P E R T Y O F G 4 D E S I G N ST U D I O S , L L C A N D I S N O T T O BE C O P I E D , R E P R O D U C E D , O R TH E C O N T E N T T H E R E O F U S E D , IN W H O L E O R I N P A R T , WI T H O U T T H E P R I O R W R I T T E N CO N S E N T O F S T E V E G U I L D 1/4" = 1'-0" 9/ 2 6 / 2 0 2 4 1 1 : 0 1 : 0 5 A M A-3 SECOND FLOOR PLAN DO U S E V I C Z 12 5 , 1 2 7 A U R O R A G4 G4 9/24/2024 EDGE WD. SO U T H B U R L I N G T O N , V E R M O N T OPTION #1B 1/4" = 1'-0"1 SECOND FLOOR PLAN First Floor 412' - 5 1/2" First Floor TP421' - 6 5/8" Second Floor 422' - 6 5/8" Second Floor TP430' - 7 3/4" Garage Slab 411' - 0" 8' - 1 1 / 8 " 1' - 0 " 9' - 1 1 / 8 " 9' - 0 " 10" 12" 10" 12" 3:12 PITCH STANDING SEAM ROOF 7.5:12 SLOPE 7.5:12 SLOPE 10" 12" 10" 12" Pre-Con. Grade 410' - 0" 25 ' - 7 " + / - First Floor 412' - 5 1/2" First Floor TP 421' - 6 5/8" Second Floor422' - 6 5/8" Second Floor TP 430' - 7 3/4" 9' - 1 1 / 8 " 1' - 0 " 8' - 1 1 / 8 " 10" 12" 10" 12" 7.5:12 SLOPE 10" 12" 10" 12" Pre-Con. Grade 410' - 0" HG H T . T O M I D P O I N T O F R O O F 25 ' - 7 " + / - First Floor 412' - 5 1/2" First Floor TP 421' - 6 5/8" Second Floor422' - 6 5/8" Second Floor TP 430' - 7 3/4" 3" 12" 7 1/2" 12" 6" 12" Pre-Con. Grade 410' - 0" 25 ' - 7 " + / - First Floor 412' - 5 1/2" First Floor TP 421' - 6 5/8" Second Floor 422' - 6 5/8" Second Floor TP430' - 7 3/4" Garage Slab 411' - 0" 3" 12" 7 1/2" 12" 6" 12" Pre-Con. Grade 410' - 0" 25 ' - 7 " + / - SHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILD SCALE: DATE: DRAWN BY: CHECKED BY: PROJECT: 9/ 2 6 / 2 0 2 4 1 1 : 0 1 : 1 9 A M 3/16" = 1'-0"A-4EXTERIOR ELEVATIONSDOUSEVICZ 125, 127 AURORA G4 G4 9/24/2024 EDGE WD.SOUTH BURLINGTON, VERMONT OPTION #1B 3/16" = 1'-0"1 FRONT ELEVATION 3/16" = 1'-0"2 REAR ELEVATION 3/16" = 1'-0"4 LEFT ELEVATION 3/16" = 1'-0"3 RIGHT ELEVATION