Loading...
HomeMy WebLinkAboutZP-24-335 - 0089 Daniel Drive 10/10/2024ZP-24-335 10/2/2024 1,144.10 single family home R1 PRD #SD-22-10A 01/19/2023 x 10/10/2024 (Acting) 10/26/2024 10/09/2025 x   VIA HAND‐DELIVERY    September 16, 2024    Betsy Brown  South Burlington Planning and Zoning   180 Market Street  South Burlington, VT 05403      Re:   Zoning Permit Application 89 Daniel Drive, South Burlington, VT 05403     Betsy,    Further to Final Plat Permit SD‐22‐10A, enclosed please find a zoning permit application  for 89 Daniel Drive, South Burlington, Vermont 05403, Unit 35‐11 on the Final Plat/Site Plan  submitted as part of SD‐22‐10A.  Also enclosed please find:    1. A Water Allocation Application;  2. A Wastewater Allocation Application.  3. A wastewater Connection Application.   4. A site plan of the applicable area of the proposed home.   5. An architectural drawing showing compliance with plans proposed and permitted in SD‐ 22‐10A.     Regarding the height of the proposed structure, it is calculated per the approved  methodology and is listed on the zoning permit application as such.        Please contact us with any questions or concerns.            Sincerely,           Brandon Secl, Estimator   Property Owners Name:O'Brien Eastview Property Location:89 Daniel Drive Amount:11,250.55 Payment Type:check #2559 Date:10/2/2024 Code Zoning Permit (New Residential)ZP-24-335 zp Recording fee 13.00$ plus addition/alteration cost 5.00$ per $1,000 project cost -$ OR: plus 1630 0.45$ per sq. ft. 733.50$ plus 1488 0.20$ per sq. ft. 297.60$ plus 2 50.00$ per bay 100.00$ After-the fact of 50% [no NOV] or 100% [NOV] -$ Zoning Permit Total 1,144.10$ Sewer Allocation Fee WWA-24-150 #204 249.15 g.p.d x 16.17$ 4,028.76$ Bartlett Bay x Airport Parkway Impact Fee Administrative Fee #248 per application $100.00 School Impact Fee #222S 2 bedroom 4,454.51$ Recreation Impact Fee* #220 /unit -$ South Village Recreation Impact Fee #243 /unit -$ Road Impact Fee #221 $963.73 /unit 963.73$ Fire Impact Fee #203 /unit -$ Police Impact Fee #222 $496.45 /unit 496.45$ Dorset Street Waterline Fee #230 /unit -$ Sewer Connection Inspection WWC-24-56 ww 63.00$ per connection 63.00$ *credit issued by City Council on 6/26/23 Total (Impact Fees + Permit) 11,250.55$ Planning & Zoning Invoice Residential Impact & Permit Fees garage bay(s) at Amount Due sq. ft building at sq. ft unfinished basement at JOB NO: DRAWN: PROJ MGR: CHECKED: IS S U E D A T E : O' B r i e n H o m e F a r m S i n g l e F a m i l y D o w n h i l l L o t So u t h B u r l i n g t o n , V T 0 5 4 0 3 AGN0.1 09 / 0 1 / 1 7 COVER SHEET, SHEET INDEX 89 D a n i e l D r i v e Trillium Farmhouse Elevation - A SHEET INDEX A4.1.3 DECK OPTIONS AGN0.1 COVER SHEET, SHEET INDEX AGN0.2 GENERAL NOTES RANCH ELEVATION A A0.1A FOUNDATION/BASEMENT PLAN-A A1.1A MAIN FLOOR PLAN-A A3.1A EXTERIOR ELEVATIONS & ROOF PLAN-A A4.2.1A OPT. WALKOUT BASEMENT - A A4.3.1A OPT. COVERED DECK - A A6.1A BUILDING SECTIONS-A 2 STORY ELEVATION A RANCH ELEVATION B A0.1B FOUNDATION/BASEMENT PLAN-B A1.1B MAIN FLOOR PLAN-B A3.1B EXTERIOR ELEVATIONS & ROOF PLAN-B A6.1B BUILDING SECTIONS-B 2 STORY ELEVATION D ALL ELEVATIONS A4.1.1 OPT. FINISHED BASEMENT A4.1.2 OPT. FLOOR PLANS A5.1 STAIR SECTION ELECTRICAL E0.1A BASEMENT ELECTRICAL PLAN-A E1.1A MAIN FLOOR ELECTRICAL PLAN-A E0.1B BASEMENT ELECTRICAL PLAN-B E1.1B MAIN FLOOR ELECTRICAL PLAN-B E4.1.1 FINISHED BASEMENT ELECTRICAL STRUCTURE S0.1A MAIN FLOOR FRAMING PLAN-A S1.1A ROOF FRAMING PLAN-A S0.1B MAIN FLOOR FRAMING PLAN-B S1.1B ROOF FRAMING PLAN-B DETAILS AD.2 DETAILS AD.1 DETAILS AD.3 DETAILS South Burlington, Vermont O'Brien Home Farm Single Family Downhill Lot Trillium Square Footages-Trillium A Elevation A MAIN FLOOR LIVING 1630 SF TOTAL LIVING 1630 SF PLAN OPTIONS OPT. FINISHED BASEMENT 851 SF TRILLIUM REVISIONS GRADING PLAN LANDSCAPE PLAN 20 ' - 9 1 / 2 " 7 ' - 0 " 2 8 ' - 2 1 / 2 " Storage 56 ' - 0 " 6 ' - 0 " 5'-6"5'-6" 39'-0" 35 ' - 8 " 2 2 ' - 4 " 4 ' - 0 " Unfinished Basement Unexcavated 1 A5.1 1 A6.1A 2 A6.1A 8"12'-8"5'-8"8"1'-2"16'-4"1'-10" WH FURN 11'-0"14'-0"14'-0" 4040 SLD4040 SLD 7'-0"7'-0" 7'-0"7'-0" 7'- 0 " 8 " 4 ' - 5 1 / 4 " 8 ' - 8 1 / 4 " 3 ' - 4 1 / 2 " 3 ' - 1 1 " 6 ' - 0 3 / 4 " 1 3 '- 2 1 / 4 " 8 " 8 ' - 0 " 19'-8"19'-4" 39'-0" 9' - 0 " 147 147 146146 F-2 F-2 F-2 F-P BEARING WALL F-C F-C 8"6'-0"6'-4"6'-0"8" 8" 4 1/2" 3'-4"6'-6"4'-9 1/2"3'-0"4"19'-4"8" F-2 F-2 W-8 TYPICAL UP 15 RISERS 124 2x6 BEARING WALL 8' - 0 " 148148148148 148148 131 148148 131 8"10'-2 1/2"8" 8"8" 12 ' - 1 1 / 4 " 2 - 2 x 1 0 FL U S H B E A M 2 - 1 3/4" x 11 7/8" LVL DROPPED BEAM 3 - 1 3/4" x 11 7/8" DROPPED BEAM 4 - 2x10 DROPPED BEAM 2 - 2x10 P.T. DECK BEAM 2'-8 1/4"2'-8 3/4"1'-9" 4 1 / 4 " MECHANICALS TO BE LOCATED AT FULL DISCRETION OF O'BRIEN BROTHERS 3068 CONSTRUCTION ASSEMBLIES: T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANS A. ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE. B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER. C. TYPICAL FLOOR CONSTRUCTION: FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILING: 1/2" GYPSUM BOARD. D. CONCRETE SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL. GENERAL BASEMENT PLAN NOTES: * ALL UNDIMENSIONED PARTITIONS ( ) ARE 3 1/2" ROUGH UNLESS NOTED OTHERWISE. * IF MAIN FLOOR FRAMING IS TO BE INSTALLED BEFORE CONCRETE FLOOR, PROVIDE THE FOLLOWING: ** AT PAD FOOTINGS, PROVIDE 8"x8" CONCRETE PEDESTAL FLUSH WITH CONCRETE FLOOR FOR ATTACHMENT OF POST BASE ** AT CONTINUOUS FOOTINGS UNDER FRAMING BEARING WALLS, PROVIDE 6" WIDE CONTINUOUS CONCRETE STEM, TOP OF STEM FLUSH WITH CONCRETE FLOOR & CENTERED ON FOOTING. * ALL ANGLED PARTITIONS ARE 45 DEGREES UNLESS NOTED OTHERWISE. * ALL EXTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE. * WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS MEETS ALL EMERGENCY EGRESS REQUIREMENTS. * ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. * ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS UNLESS NOTED OTHERWISE. * TRUSS MFG. TO SIZE MEMBERS, FASTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. * FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. * TYPICAL WINDOW HEAD HEIGHTS SHALL BE 7'-0" A.F.F. (U.N.O.) SYMBOL TYPE SIZE FOOTING SCHEDULE F-P PIER (EXTERIOR) REINFORCING 12" SONOTUBE W/ BELL BOTTOM NA F-C CONTINOUS FOOTING 2'-0" WIDE x 0'-8" DEEP 3-#4's CONTINUOUS F-2 PAD FOOTING (INTERIOR) 2'-0" x 2'-0" x 1'-0" DEEP NA COLUMN 6x6 TREATED POST NA *NOTE: LALLY COLUMNS SHALL HAVE THE ALLOWABLE MINIMUM LOAD CAPACITY OUTLINED IN THE GENERAL NOTES. SEE GENERAL NOTES FOR BOTTOM AND TOP BEARING PLATES. COMMENTS 48" MIN. BELOW FINISH GRADE 3 1/2" LALLY COLUMN UNLESS NOTED OTHERWISE* SYMBOL WALL THICKNESS WALL HEIGHT FOUNDATION WALL SCHEDULE W-8 8"9'-0" REINFORCING 2 #4 BARS TOP & BOTTOM *CONTINUOUS FOOTING 1'-4"x 0'-8" W/ 2-#4's CONTINUOUS *IF FOOTING IS BEARING ON EARTH BUILDER TO VERIFY SOIL PRESSURE AND USE 2'-0"x0'-8" CONTINUOUS FOOTING JOB NO: DRAWN: PROJ MGR: CHECKED: IS S U E D A T E : O' B r i e n H o m e F a r m S i n g l e F a m i l y D o w n h i l l L o t So u t h B u r l i n g t o n , V T 0 5 4 0 3 A0.1A 09 / 0 1 / 1 7 FOUNDATION/BASEMENT PLAN-A 89 D a n i e l D r i v e SCALE:1/4" = 1'-0" (22x34) Foundation/Basement Plan TRILLIUM KEYNOTES: FLOOR PLAN 101 SINK W/ GARBAGE DISPOSAL. 102 DISHWASHER. 103 REFRIGERATOR. 104 RANGE W/ HOOD/MICRO. 108 BASE CABINETS. 109 UPPER CABINETS. 110 WATER CLOSET. 111 LAV. SINK. 113 SHOWER (SIZE PER PLAN). 115 DROP IN TUB W/ PLATFORM. 116 TUB/SHOWER (SIZE PER PLAN). 117 LINEN SHELVES PER BUILDER SPEC. 118 WASHER. 119 DRYER. 121 LINE OF SHELF ABOVE. 122 ROD & SHELF. 123 ATTIC ACCESS (22"x30" U.N.O.). 124 HANDRAIL. 125 SOLID CORE DOOR W/ SELF CLOSER. 126 LINE OF OVERHEAD GARAGE DOOR IN OPEN POSITION. 127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD IN GARAGE AS REQUIRED BY CODE. 128 SLOPE GARAGE FLOOR 1/8" PER FOOT TOWARD GARAGE DOOR OPENING. 130 LINE OF SOFFIT ABOVE (REFER TO EXTERIOR ELEVATIONS FOR HEIGHTS AND DETAILS). 131 GYPSUM BOARD SOFFIT (HEIGHT AS NOTED). 132 LINE OF FRAMING ABOVE. 133 LINE OF FRAMING BELOW. 137 42" HIGH EXTERIOR GUARDRAIL W/ BALUSTERS TO BE SPACED SUCH THAT 4" SPHERE CANNOT PASS BETWEEN BALUSTERS. 139 2X4 LOW WALL 36" A.F.F. 144 WINDOW SEAT (HEIGHT AS NOTED) 146 WINDOW WELL AS SPECIFIED BY BUILDER 147 LINE OF DECK ABOVE. 148 BEAM POCKET. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. OPTIONAL OPTIONAL REVISIONS CONSTRUCTION ASSEMBLIES: T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANS A. ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE. B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER. C. TYPICAL FLOOR CONSTRUCTION: FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILING: 1/2" GYPSUM BOARD. D. CONCRETE SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL. Owners Suite Dining Kitchen Living Room Ow n e r s B a t h W.I.C. Laundry Mudroom Foyer Bath 2 Porch 3060 DH 3060 DH3060 DH 3060 DH 3060 DH 3060 DH 40 4 0 F X 3060 DH3060 DH 11'-2 9/16"14'-0"14'-0" 39'-2 9/16" 3' - 6 " 3 ' - 6 " 8" 5 ' - 4 " 1 1 ' - 1 1 1 / 2 " 2 ' - 4 1 / 2 " 5 ' - 4 1 / 2 " 1 ' - 1 " 7 ' - 0 " 5 ' - 1 " 23 ' - 1 1 / 2 " 10 ' - 4 " 5 ' - 1 " 4 ' - 6 " 1 5 ' - 9 " 35 ' - 8 " 2 2 ' - 4 " 4 ' - 0 " 3'-8 9/16"6'-4"3'-4 13/16" 2'-11 1/4"2'-10" 10'-0"10'-0" 7'-0"7'-0" Bench ST O R A G E Bedroom 2 Foyer 2 Car Garage DN AS REQ DN AS REQ 56 ' - 0 " 6 ' - 0 " 60 1 0 T R N A B V . 3010 FX TRANS ABV. 8"5'-8"8"5'-8"8"5'-8"8" 19'-8"19'-4" 39'-0" 13'-5 5/16"5'-9 1/4"20'-0" 7'-0"7'-0" 3' - 4 " 8 " 8' - 5 1 / 2 " 1 7 ' - 2 " 2 ' - 7 " 3 ' - 4 " 3 ' - 8 " 8 " 1 ' - 1 0 " 2 ' - 6 " 3 ' - 6 1 / 2 " 4 ' - 9 1 / 2 " 5 1 / 2 " 15 ' - 5 " 0 " 3 ' - 6 " 4 1 / 2 " 2 ' - 9 " 4 " 4 ' - 0 1 / 2 " 4 " 8 " 1 3 ' - 1 1 / 2 " 9 ' -0 " 5 1 / 2 " 9 ' - 3 1 / 2 " 3 ' - 0 " 1 5 ' - 0 " 12'-6 5/16"3 1/2"5'-9 1/4"20'-2" 8'-7 1/16"4'-2 13/16"5'-9 1/4"5 1/2"5'-10 1/2"3 1/2"5'-6 1/2" 2'-6 1/16"2'-4"5'-9 1/2"7'-11 1/2"3'-10"2'-6"3 1/2"3'-6"2'-0 1/2"7'-6 1/2" 0"25'-2 9/16"3'-6"9'-7" 42"x54" 33"x60" PANTRY DN 15 RISERS 4'-1 9/16"4 1/2"5'-10" 8' - 0 " 1'-0" 2x6 WALL 2x4 WALL 2x4 WALL 2x4 WALL 2x 6 W A L L 2x6 WALL 2x 6 W A L L 2' - 4 " 2 ' - 9 " 2x6 WALL 8'-0" SOFFIT 12'-6 5/16" 11 ' - 6 " 13'-1" 4' - 6 " HOSEBIB 7'- 0 " 2'-2 1/2" 3'-8" 2' - 5 1 / 2 " 3'-11 5/16"2'-9"5'-6 9/16" 7'-3"9'- 1 0 1 / 2 " 30 6 0 D H HALF WALL 40 2 0 F X 30 6 0 D H +/- 3'-7 3/16" 3' - 7 1 1 / 1 6 " 20 4 0 D H HOSEBIB GENERAL FLOOR PLAN NOTES: * ALL UNDIMENSIONED PARTITIONS ( ) ARE 3 1/2" ROUGH UNLESS NOTED OTHERWISE. * ALL EXTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE. * ALL ANGLED PARTITIONS ARE 45 DEGREES UNLESS NOTED OTHERWISE. * WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS MEETS ALL EMERGENCY EGRESS REQUIREMENTS. * ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. * ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS UNLESS NOTED OTHERWISE. * TRUSS MFG. TO SIZE MEMBERS, FASTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. * FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. * TYPICAL WINDOW HEAD HEIGHTS SHALL BE 8'-0 7/8" A.F.F. (U.N.0.) W/ 9'-1 1/8" CLG. AND 7'-0 7/8" A.F.F (U.N.O.) W/ 8'-1 1/8" CLG. * PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. JOB NO: DRAWN: PROJ MGR: CHECKED: IS S U E D A T E : O' B r i e n H o m e F a r m S i n g l e F a m i l y D o w n h i l l L o t So u t h B u r l i n g t o n , V T 0 5 4 0 3 A1.1A 09 / 0 1 / 1 7 MAIN FLOOR PLAN-A 89 D a n i e l D r i v e SCALE:1/4" = 1'-0" (22x34) Main Floor Plan TRILLIUM KEYNOTES: FLOOR PLAN 101 SINK W/ GARBAGE DISPOSAL. 102 DISHWASHER. 103 REFRIGERATOR. 104 RANGE W/ HOOD/MICRO. 108 BASE CABINETS. 109 UPPER CABINETS. 110 WATER CLOSET. 111 LAV. SINK. 113 SHOWER (SIZE PER PLAN). 115 DROP IN TUB W/ PLATFORM. 116 TUB/SHOWER (SIZE PER PLAN). 117 LINEN SHELVES PER BUILDER SPEC. 118 WASHER. 119 DRYER. 121 LINE OF SHELF ABOVE. 122 ROD & SHELF. 123 ATTIC ACCESS (22"x30" U.N.O.). 124 HANDRAIL. 125 SOLID CORE DOOR W/ SELF CLOSER. 126 LINE OF OVERHEAD GARAGE DOOR IN OPEN POSITION. 127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD IN GARAGE AS REQUIRED BY CODE. 128 SLOPE GARAGE FLOOR 1/8" PER FOOT TOWARD GARAGE DOOR OPENING. 130 LINE OF SOFFIT ABOVE (REFER TO EXTERIOR ELEVATIONS FOR HEIGHTS AND DETAILS). 131 GYPSUM BOARD SOFFIT (HEIGHT AS NOTED). 132 LINE OF FRAMING ABOVE. 133 LINE OF FRAMING BELOW. 137 42" HIGH EXTERIOR GUARDRAIL W/ BALUSTERS TO BE SPACED SUCH THAT 4" SPHERE CANNOT PASS BETWEEN BALUSTERS. 139 2X4 LOW WALL 36" A.F.F. 144 WINDOW SEAT (HEIGHT AS NOTED) 146 WINDOW WELL AS SPECIFIED BY BUILDER 147 LINE OF DECK ABOVE. 148 BEAM POCKET. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. OPTIONAL OPTIONAL REVISIONS MAIN FLOOR MAIN PLATE T.O.F. BASEMENT FLOOR 9' - 1 1 / 8 " 11 1 / 2 " 8 ' - 8 " DORMER PLATE 10" 12" 10" 12" 14 ' - 6 " 8' - 3 " 10 AD.2 (2) 2026 FX BLACKOUT @ 13'-6" H.H. 3 AD.1 3 AD.2 2030 FX BLACKOUT @ 17'-4" H.H. AD.3 3 SIM 8 AD.2 RAISED HEEL MAIN FLOOR MAIN PLATE 8'- 8 " 1 1 1 / 2 " 9 ' - 1 1 / 8 " T.O.F. BASEMENT FLOOR 9 AD.2 1 AD.2 5 AD.2 RAISED HEEL 5' - 4 " MAIN FLOOR MAIN PLATE 9' - 1 1 / 8 " 11 1 / 2 " 8' - 8 " T.O.F. BASEMENT FLOOR 6" 12"6" 12" 4" 12" DORMER PLATE 14 ' - 6 " 8' - 3 " 1 AD.2 8 AD.2 3 AD.2 RAISED HEEL MAIN FLOOR MAIN PLATE T.O.F. BASEMENT FLOOR 9' - 1 1 / 8 " 11 1 / 2 " 8' - 8 " 6" 12" 6" 12" 8' - 3 " 1 AD.2 3 AD.1 8 AD.2 RAISED HEEL 19 ' PCG JOB NO: DRAWN: PROJ MGR: CHECKED: IS S U E D A T E : O' B r i e n H o m e F a r m S i n g l e F a m i l y D o w n h i l l L o t So u t h B u r l i n g t o n , V T 0 5 4 0 3 A3.1A 09 / 0 1 / 1 7 EXTERIOR ELEVATIONS & ROOF PLAN-A 89 D a n i e l D r i v e Elevation - Farmhouse SCALE:1/4" = 1'-0" (22x34) Front Elevation SCALE:3/16" = 1'-0" (22x34) Rear Elevation SCALE:3/16" = 1'-0" (22x34) Left Elevation SCALE:3/16" = 1'-0" (22x34) Right Elevation TRILLIUM NOTE: * REQUIRED NET FREE VENTED AREAS ARE CALCULATED BY MULTIPLYING THE ACTUAL ATTIC AREA (SQ FT) IN COLUMN 1 BY 1/300 AND MULTIPLYING SUM BY 144 SQ IN/SQ FT 40%-50% OF TOTAL NET FREE VENTED AREA IS REQUIRED AT THE RIDGE (HIGH) AND THE REMAINING IS THE REQUIRED IN THE SOFFIT (LOW). WHEN NO "HIGH/LOW" VENTING IS PROVIDED, THE REQUIRED NET FREE AREA IS 1/150 OF THE ACTUAL AREA AND 100% OF THIS VENTED AREA SHALL BE PROVIDED AT THE SOFFIT. ** ACTUAL NET FREE VENTED SOFFIT AREAS ARE CALCULATED BY DIVIDING THE REQUIRED NET FREE VENTED SOFFIT AREA (FT) BY THE MANUFACTURERS STATED ACTUAL VENTED NET FREE AREA PER VENT. WHEN APPLICABLE, THE ACTUAL TOTAL NUMBER OF SOFFIT VENTS SHALL BE DIVIDED EQUALLY BETWEEN EACH EAVE AND SPACED AN EQUAL DISTANCE APART FROM ONE ANOTHER. ACTUAL NET FREE VENTED RIDGE AREAS ARE CALCULATED BY DIVIDING THE REQUIRED NET FREE VENTED RIDGE AREA... ATTIC VENTILATION SCHEDULE (ELEVATION A) Name Area TOTAL NET VENTED (1/300) (SQ IN) TOTAL NET VENTED (1/150) (SQ IN) *LOWER VENT MIN (50%) *LOWER VENTED MAX (60%) *UPPER VENT MIN (40%) *UPPER VENT MAX (50%) MAIN ROOF 2229 SF 1070 in² 2140 in² 535 in² 642 in² 428 in² 535 in² REVISIONS CONSTRUCTION ASSEMBLIES: T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANS A. ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE. B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER. C. TYPICAL FLOOR CONSTRUCTION: FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILING: 1/2" GYPSUM BOARD. D. CONCRETE SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL. MAIN FLOOR MAIN PLATE T.O.F. BASEMENT FLOOR 9'- 1 1 / 8 " 11 1 / 2 " 8' - 8 " 7 3/4" MAX. RISERS 10" MIN. TREADS 15 E Q U A L R I S E R S 9'- 7 1 / 2 " 6 TREADS @ 10" EA = 5'-0" 7 TREADS @ 10" EA = 5'-10" MI N . C L E A R A N C E 6' - 8 " 3' - 2 " M A X . 2' - 1 0 " M I N . HANDRAIL JOB NO: DRAWN: PROJ MGR: CHECKED: IS S U E D A T E : O' B r i e n H o m e F a r m S i n g l e F a m i l y D o w n h i l l L o t So u t h B u r l i n g t o n , V T 0 5 4 0 3 A5.1 09 / 0 1 / 1 7 STAIR SECTION 89 D a n i e l D r i v e SCALE:1/4" = 1'-0" (22x34)1 Stair Section TRILLIUM REVISIONS CONSTRUCTION ASSEMBLIES: T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANS A. ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE. B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER. C. TYPICAL FLOOR CONSTRUCTION: FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILING: 1/2" GYPSUM BOARD. D. CONCRETE SLAB CONSTRUCTION: 4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL. MAIN FLOOR MAIN PLATE T.O.F. BASEMENT FLOOR 8' - 8 " 11 1 / 2 " 9' - 1 1 / 8 " ROOF TRUSSES @ 24" O.C. 62'-0" HEEL 1'-4" Dining Kitchen Bedroom 2 Unfinished Basement A C B1 D 6'-0"56'-0" HEEL 1'-4" 6" 12" Storage MAIN FLOOR MAIN PLATE T.O.F. BASEMENT FLOOR 8'-8" 11 1/2" 9'-1 1/8" DORMER PLATE ROOF TRUSSES @ 24" O.C. 58'-0" Owners Suite Owners Bath Laundry 2 Car Garage Unfinished Basement HEEL 1'-4" HEEL 1'-4" CB1 D 4" 12" 6" 12" 6" 12" 14'-6" HEEL 4" A JOB NO: DRAWN: PROJ MGR: CHECKED: IS S U E D A T E : O' B r i e n H o m e F a r m S i n g l e F a m i l y D o w n h i l l L o t So u t h B u r l i n g t o n , V T 0 5 4 0 3 A6.1A 09 / 0 1 / 1 7 BUILDING SECTIONS-A 89 D a n i e l D r i v e Elevation - A SCALE:1/4" = 1'-0" (22x34)1 Building Section SCALE:1/4" = 1'-0" (22x34)2 Building Section TRILLIUM REVISIONS