Loading...
HomeMy WebLinkAboutSP-24-23 - Supplemental - 0200 Garden Street (14)314 315 306 307 310 3 10 309 313 314WW F M + 315.02 315.34 + +312.85 + 312.85 +313.35 310.85 + + 3 1 0 .5 0 + (3 1 2.12) + 31 0. 7 5 310.55 + +3 1 0.5 5 +310.85 +310.65 311.25+ + +314.22 314.50 315.32+ + (30 8.2) 314.95 + 314.65 + + (309.89) + (310.33) + (310.88) (310.73) + (3 11.8 8) ++ (3 1 2.48) 3 1 3.60 + 316.36++ 31 2.0 0 + 3 11.0 0 + +314.03 3 13.3 0 ++313.60 +313.60 305.25 + +314.5 +312.0 + T O W = 3 08.0 E T L L L G 311 304 3 0 6 311 3 0 8 306 310 3 0 9 3133 1 3 314 315 3 0 5 U D U D 15'R 2 5'R 25 'R 315 315 3 1 3 314 E T T + 314.75 + 314.34 + 315.28 + 314.95 + 314.42 + 314.92 + 315.13 + 315.13 314 3 15 315 W G G G G G G UD UDUD UD UD UD R R R R Y DH H D Y DHY 311 310 31 4 G G G GG E T E T L L L L L L L L L L E T E T E E E W WWW W W W S S S S S S S S R D R D FM D D D S S HH BB 2 2 14 14 5'-0'' HIGH RTU ON 24'' HIGH BASE ROOF EQUIPMENT SCREEN PROJECT : REVISION/DATE : 1/32" = 1'-0" SOLAR-READY ZONE 23-273 02-09-2024 A-1.1 BUILDING 7 SOLAR-READY ZONE Total rooftop area = 12, 650 SF Minimum solar-ready zone = 5, 060 SF 40% X 12,650 SF = 5,060 SF Total solar-ready zone available = 5, 221 SF (solar-ready zone areas shown subject to adjustment with final design of mechanical equipment) The solar-ready zone shall include a collateral dead load of not less than 5 psf in gravity and lateral design calculations. Interconnection pathways shall be provided for routing of conduit or piping from the solar- ready zone to the electrical service panel or service hot water system. The main electrical service panel shall have a reserved space to allow installation of a dual pole circuit breaker for future solar electric installation and labeled ''FOR FUTURE SOLAR ELECTRIC''. The reserved space shall be positioned at the end of the panel that is opposite from panel supply conductor connection. A permanent certificate, indicating the solar- ready zone and other requirements, shall be posted near the electric distribution panel, water heater, or other conspicuous location. 4 2 3 1 06-18-2024 SOLAR ZONE Total rooftop area = 12, 650 SF Minimum solar zone = 5,060 SF 40% X 12,650 SF = 5,060 SF Total solar zone available = 5, 221 SF (solar zone areas shown subject to adjustment with final design of mechanical equipment) The solar zone shall include a collateral dead load of not less than 5 psf in gravity and lateral design calculations. Interconnection pathways shall be provided for routing of conduit or piping from the solar zone to the electrical service panel or service hot water system. The main electrical service panel shall have space for installation of a dual pole circuit breaker for solar electric installation and labeled ''FOR SOLAR ELECTRIC''. This space shall be positioned at the end of the panel that is opposite from panel supply conductor connection. PROJECT : REVISION/DATE : VIEW 1 23-273 02-09-2024 A-1.2 BUILDING 7 PROJECT : REVISION/DATE : VIEW 2 23-273 02-09-2024 A-1.3 BUILDING 7 PROJECT : REVISION/DATE : VIEW 3 23-273 02-09-2024 A-1.4 BUILDING 7 PROJECT : REVISION/DATE : VIEW 4 23-273 02-09-2024 A-1.5 BUILDING 7