HomeMy WebLinkAboutPermit Wastewater Allocation WWA-23-122 (2)CLASS II WETLAND (TYP)
WETLAND BUFFER (TYP)
50'
DORSET STREET
EXISTING
PROPERTYLINE
EXISTING
SEARS AUTOCENTER
EX
I
S
T
I
N
G
8
"
D
.
I
.
W
A
T
E
R
M
A
I
N
EXISTING 4"
D.I. WATER
SERVICE
EXISTING 8"
SDR35 SEWER
SERVICE
EXISTING 8" D.I. WATER MAIN
PROFESSIONAL
SERVICES / RETAIL
(2,255 SF)
TENANT B
CASUAL RESTAURANT
(PRIMARILY TAKEOUT)
(1,677 SF)
TENANT D
HEALTH AND
WELLNESS RETAILER
(2,389 SF)
TENANT E
CASUAL RESTAURANT
(PRIMARILY TAKEOUT)
(1,656 SF)
TENANT F
CASUAL
RESTAURANT
(2,902 SF)
MECHANICAL
ROOM
(249 SF)
CO
M
M
O
N
C
O
R
R
I
D
O
R
(
1
,
0
8
1
S
F
)
TENANT A
FITNESS
(2,615 SF)
22'
Drawing Title
Designed by
No.
of
Project Number
Sheet
Drawing Number
Drawing Title
Issued for
Checked byDesigned by
Appvd.DateRevisionNo.
Sa
v
e
d
Fr
i
d
a
y
,
M
a
r
c
h
2
4
,
2
0
2
3
3
:
4
9
:
1
7
P
M
DH
E
I
L
P
l
o
t
t
e
d
Mo
n
d
a
y
,
M
a
r
c
h
2
7
,
2
0
2
3
1
1
:
3
4
:
4
2
A
M
Da
n
H
e
i
l
\\vhb.com\gbl\proj\SBurlington\58718.00 U Mall\cad\ld\Planset\Sears Auto Renovation\5871800-SP.dwg
vh
b
.
c
o
m
Date
40 IDX Dr
Building 100 Suite 200
South Burlington, VT 05403
802.497.6100
Multi-Tenant Building
225 Dorset Street
South Burlington, VT 05403
DRAFT
Not Approved for Construction
Mar. 17, 2023
1
58718.00
Feet40.000120010
Site Plan
C2.02
1
DJH DJH
Computations
Project:Multi-Tenant Building Project #:58718.00
Location:225 Dorset Street Sheet:
Calculated by:DJH Date:04/03/2023
Checked by: Date:
Title:Existing Water and Wastewater Allocation Calculations
Multi-Tenant Building
225 Dorset Street
Exisiting Water and Wastewater Allocations
Existing Water / Wastewater Allocation* Sears Auto
Quantity Unit
26 Employees 15 gpd/emp
*Based on the State Environmental Protection Rules, Chapter 1, Table 8‐3
Proposed Water / Wastewater Allocation* Multi‐Tenant Building
Quantity Unit
45 Seats 27 gpd/seat
1 Restaurant 300 gpd
2389 SF 4 4gpd/100 SF
1 Restaurant 300 gpd
2615 SF 4 4gpd/100 SF
10 Employees 15 gpd/emp
*Based on the State Environmental Protection Rules, Chapter 1, Table 8‐3
300
96
300
105
150
Increase In Demand 1776
390
Use Design Flow (gpd)
Restaurant (2 Meals / Day)1215
Demand
Total
2166
Restaurant (less than 9 seats)
Retail
Professional Services
Restaurant (less than 9 seats)
Retail
Total
Use Design Flow (gpd)
Automotive Repair 390
Demand
1
A300
2
A300
Common / Mech / Fire Pump
/ Elec / Telecom
Common Corridor
Proposed Financial Institution
Tenant A
Tenant B
Tenant C
Tenant D
Tenant E
Tenant F
2,389 SF
Tenant D
2,255 SF
Proposed
Financial
Institution
249 SF
Common /
Mech / Fire
Pump / Elec /
Telecom
1,677 SF
Tenant B
1,656 SF
Tenant E
2,902 SF
Tenant F
1,081 SF
Common
Corridor
8'
-
0
"
34'-2 3/4"18'-9 3/4" 28'-5 1/4" 19'-8 3/4" 36'-5" 31'-11 3/4"
4'-4 1/2"84
'
-
8
"
12
'
-
0
"
12'-0"
L
O
A
D
I
N
G
D
O
R
S
E
T
S
T
R
E
E
T
NEW LANDING
TYPICAL
2,615 SF
Tenant A
SCALE
DATE
1/16" = 1'-0"A101University Mall
South Burlington, VT
Sears Auto Center Building
03/06/2023
PLAN--
0'16'
32'8'N
Casual
Restaurant - 2
meals per day
(45 seats)
Casual
Restaurant -
Primarily
Takeout (less
than 9 seats)
Casual
Restaurant -
Primarily
Takeout (less
than 9 seats)
Retail Professional
Services w/ 10
employees
Retail