HomeMy WebLinkAboutSD-24-11 - Supplemental - 0252 Autumn Hill Road (12)
SOUTH BURLINGTON
WATER DEPARTMENT
SBWD Technical Review Comments SD-24-11 252 Autumn Hill Rd.
Date: June 12, 2024
Submitted by Jay Nadeau, SBWD Superintendent
1. The following note must be provided on all plan sheets and detail pages: All water lines and
appurtenances shall be installed in accordance with the Champlain Water District Specifications
and Details for the Installation of Water Lines and Appurtenances, current edition, henceforth
CWD Specifications.” The SBWD will be inspecting construction based on the CWD Specifications.
2. The project shall be constructed, completed, maintained, and operated in accordance with the
approved plans. No water infrastructure changes shall be made to the project without the written
approval of the SBWD.
3. When a pipe material is specifically noted on the approved project drawings, the
contractor/developer shall not have the option of utilizing any other pipe material.
4. Curb boxes located in roadways or sidewalks shall be placed inside a gate valve box top section
with cover and brought to final pavement/concrete grade with one non-adjustable paving riser.
5. V-Bio polyethylene encasement is required for all ferrous material installations underground.
This includes fittings for PVC and HDPE pipe.
6. Tracer wire and termination box specifications are required for all plastic pipe.
7. The SBWD shall be notified in advance to inspect all mechanical joint fittings, main line taps,
appurtenances, thrust blocks, and water line crossings prior to occurrence of back filling.
8. No parallel underground utility (ex. phone, electric, cable, gas) shall be designed or installed
within four feet (4’) of the water line from either side, or above the water line from the bottom of the
line to finish grade. Storm sewer and sanitary sewer separations are only allowed as in the specifications
and the VT Water Supply Rule. No building or structure shall be built above the water line or within
any water line easement.
9. Connections will only be permitted between the hours of 7:00am and 3:00pm on regular
Champlain Water District business days, except Fridays. All connections must be completed by
3:00pm; connections that cannot be completed by 3:00pm may be suspended and completed the
following business day. A suspended tap may entail back filling the excavation until the following day.
SBWD personnel have the authority to suspend connections that they deem cannot be completed within
the time period stated above.
SOUTH BURLINGTON
WATER DEPARTMENT
10. No water lines shall be installed after November 15 or before April 1 without prior approval of the
appropriate CWD Division. The appropriate CWD Division may restrict work before November 15 and after
April 1 during adverse weather conditions. CWD does not allow excavating water mains or service lines
during the winter months except by special permission.
11. The applicant or project engineer shall be responsible for the submittal of test results to the SBWD.
Submittal of all test results shall be required prior to the water main being placed into service.
12. Record drawings, prepared by a VT licensed Professional Engineer shall be provided to the SBWD in
pdf. and Auto-CAD format. Drawings shall include ties to all gate valves and curb stops to sub-meter
accuracy.
It is the responsibility of the contractor to be familiar with the CWD Specifications beyond what is included in
this information. The Champlain Water District Specifications and Detail for the Installation of Water Lines
and Appurtenances information can be found at www.champlainwater.org
Plan Specific Comments:
Site Plan:
1. A saddle tap shall be used when connecting the proposed 2” water service to the existing water main.
2. Exploratory excavation must be performed to confirm that there is a cap with thrust block on the end of
the existing water main that will be tapped for the new service.
3. Copper shall be used between the existing water main and a new 2” curb stop installed in accordance
with the CWD Specifications.
4. CTS tubing may be used beyond the curb stop. Tracer wire shall be required in accordance with the
CWD Specifications.
5. The 2” water service line and all appurtenances shall be considered private and the responsibility of the
property owner.
6. The South Burlington Water Department will require an easement to each curb stop outside of the City
ROW for access only. Maintenance and repairs are the responsibility of the property owner.
7. The customers connected to the proposed 2” line may be subject to water quality degradation due to the
length of the service line that will connect to an existing dead-end main. The SBWD will only be able to
flush up to the last hydrant on Windswept Lane to aid in improving water conditions. Use of the fire
hydrant on Windswept Lane will result in significant pressure fluctuations and the risk of discolored
water on the proposed 2” service line.
8. Connection fees, allocation fees, meter and backflow requirements in accordance with the City of South
Burlington Water Ordinance shall apply to this project.
9. If the ADU will have a separate water meter, then a separate curb stop shall be required for the ADU
and SFR.