HomeMy WebLinkAboutSP-24-26 - Plans - Non-Record - 0124 Nowland Farm RoadC1-00 LEGEND & NOTES
C1-01 OVERALL EXISTING CONDITIONS PLAN
C2-01 OVERALL SITE PLAN
C2-02 PARKING AREA PLAN
C2-03 WETLAND IMPACT PLAN
C2-04 WETLAND IMPACT PLAN - S BURL
C5-01 EROSION PREVENTION & SEDIMENT CONTROL PLAN
C6-01 PLAN & PROFILE
C6-02 PLAN & PROFILE
C6-03 PLAN & PROFILE
C8-01 SITE DETAILS
C8-02 SITE DETAILS
C8-03 SITE DETAILS
C8-04 LOW RISK EROSION HANDBOOK DETAIL SHEET #1
C8-05 LOW RISK EROSION HANDBOOK DETAIL SHEET #2
LI1-01 LIGHTING PLAN
LA1-01 LANDSCAPE PLAN
LA1-02 LANDSCAPE PLAN
LA2-01 LANDSCAPE DETAILS
NOWLAND FARM ROAD
SOUTH BURLINGTON, VT
HUBBARD RECREATION &
NATURAL AREA
Engineer:
TRUDELL CONSULTING ENGINEERS (TCE)
478 BLAIR PARK ROAD
WILLISTON, VT 05495
(802) 879-6331
Owner/Applicant:
CITY OF SOUTH BURLINGTON
575 DORSET STREET
SOUTH BURLINGTON, VT 05403
DRAWING INDEX
PROJECT DESCRIPTION:
THE PURPOSE OF THIS PROJECT IS TO ADD A PAVED SHARED USE PATH AND
PAVED PARKING AREA TO THE HUBBARD RECREATION AND NATURAL AREA
TO PROVIDE CONNECTIVITY FOR SOUTH BURLINGTON'S PATH NETWORK.
" PERMITTING " SUBMISSION SET
(NOT FOR CONSTRUCTION)
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
TRUDELL CONSULTING ENGINEERS
TCE PROJECT NO: 22-512
06/18/2024 LAST REVISED:
USE AND INTERPRETATION OF THE DRAWINGS
BEFORE USING THESE PLANS ENSURE THAT YOU HAVE THE LATEST REVISION
1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities. They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including,
but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans,
private and public utilities, and other pertinent permits for construction.
3. Owner and Architect are responsible for final design and location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property. Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains the most current revisions. If unsure, please contact TCE.
TAX ID: 1640-01600
UP
UP
UP
UP
UP
UP
D
G
W
W
394
394
3
9
4
394
394
3
9
4
394
39
4
393
393
39
3
393
393
393
393
3
9
3
39
3
3
9
2
392
39
2
39
2
392
392
392
392
39
2
392
392
392
392
39
2
392
392
39
2
3
9
2
39
1
391 39
1
39
1
391
391
391
3
9
1
391
391
391
391
3
9
1
391
391
39
1
391
391
391
391
390
390
390
39
0
390
39
0
390
390
390
390
390
3
9
0
390
390
3
9
0
390
3
9
0
390
390
390
390
390
3
9
0
389
389
389
389
3
8
9
389
389
389
389
389
389
389
38
9
38
9
389
389
389
389
389
3
8
9
3
8
9
388
38
8
388
388 388
388
388
388
388
38
8
388
38
8
388
3
8
8
38
8
3
8
8
388
388
388
388
38
8
387
387
387 387
387
387
387
387
387
387
3
8
7
38
7
3
8
7
387
387
387
38
7
3
8
7
387
386
386
386
38638
6
386
386
386
386
38
6
38
6
386
386
3863
8
6
386
3
8
6
385
385
385
385
3
8
5
385
385
385385
3
8
5
3
8
5
38
5
385
385
385
38
5
384
384
384384
384
3
8
4
384
384
384
384
3
8
4
38
4
384
384
384
3
8
4
383383
383
383
383
38
3
383
383
383
383
3
8
3
38
3
38
3
383
383
382
382 382
382
382
382
382 382
382
3
8
2
382
382
382
381
381 381
381
381
381
381 381 381
38
1
381
381
381
380
380
38
0
380
380
380
380 380 380
380
3
8
0
380
380
379
379
37
9
379
379
379
379 379
379
379
37
9
379
3
7
9
378378378
378
378
378
37
8
378378
3
7
8
378
377377
377
377377
377
377
377377
377
376 376 376
376 376
376 376
376
3
7
6
376
375
375 375
375 375
375 375
375
375
37
4
374
374 374
374 374
374 374
374
373
373 373
373
373 373
373
373
372
372
372372
372372372372
371
371
371371
371371371371370370370
370
370
370
3
7
0
370
3
7
0
369 369 369
369 369
369
369
3
6
9
368
36
8
368
368
368368368368
36
7
3
6
7
367
367
367367367367
366 366 366
366
366
366
3
6
6
3
6
6
36
6
365 365 365
365
365
365
36
5
36
5
365
364
3
6
4
3
6
4
364
364
364
364364364
3
6
3
3
6
3
3
6
3
363
363363
363
363
363
3
6
2
362
362
362
362
362
362
362
361
3
6
1
36
1
36
1
361
361
361361
360
3
6
0
360
360
360
360360
359
3
5
9
35
9
359
359
359
359
35
8
358
358
358
357
357
357
357
357
357
356
356
356
356
356
356
356
100
'
W
E
T
L
A
N
D
B
U
F
F
E
R
100' W
E
T
L
A
N
D
B
U
F
F
E
R
100' C
I
T
Y
W
E
T
L
A
N
D
B
U
F
F
E
R
390
39
0
390
391
39
1
39
1
3
9
1
39
1
39
1
39
0
390
39
0
3
9
0
390
3
9
0
3
9
0
3
9
0
3
8
9
3
8
9
3
8
8
3
8
8
3
8
7
387
38
7
386
EX
I
S
T
I
N
G
HO
M
E
,
TY
P
.
D
50' A
N
R
C
L
A
S
S
I
I
W
E
T
L
A
N
D
B
U
F
F
E
R
50' CITY CLASS III BUFFER
SPEAR S
T
R
E
E
T
UP
S
W
E
P
T
L
A
N
E
PINNACL
E
D
R
I
V
E
TO
S
P
E
A
R
S
T
R
E
E
T
PARK
S
I
D
E
D
R
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
E N G I N E E R I N G S U R V E Y
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E
SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLANNIN G ENVIRON MENTAL
0
Feet
Graphic Scale
60 120 180
15
°
±
VT Grid
Magnetic
C2-04
6/14/2024
1" = 60'
22-512
JLA
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
SOUTH BURLINGTON WETLAND IMPACT KEY
PROPOSED CLASS II WETLAND BUFFER IMPACT = 7016 SF
(100-ft CLASS II BUFFER PER LDR)
PROPOSED CLASS III WETLAND BUFFER IMPACT = 11,018 SF
(50-FT CLASS III BUFFER PER LDR)
PROPOSED CLASS III WETLAND IMPACT = 1,784 SF
PROJECT LOCATION
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS III
WETLAND L
CLASS III
WETLAND C
CLASS III
WETLAND M
CLASS III
WETLAND
CLASS III
WETLAND
CLASS III
WETLAND
EXISTING CLASS II WETLAND BUFFER IMPACT
PERMITTED UNDER INDIVIDUAL WETLAND PERMIT
#2014-085 = 3,195 SF
PROPOSED CLASS II WETLAND IMPACT = 283 SF
South Burlington
Wetland Impact
Plan
UP
UP
UP
UP
UP
UP
D
G
W
W
394
394
3
9
4
394
394
3
9
4
394
39
4
393
393
39
3
393
393
393
393
3
9
3
39
3
3
9
2
392
39
2
39
2
392
392
392
392
39
2
392
392
392
392
39
2
392
392
39
2
3
9
2
39
1
391 39
1
39
1
391
391
391
3
9
1
391
391
391
391
3
9
1
391
391
39
1
391
391
391
391
390
390
390
39
0
390
39
0
390
390
390
390
390
3
9
0
390
390
3
9
0
390
3
9
0
390
390
390
390
390
3
9
0
389
389
389
389
3
8
9
389
389
389
389
389
389
389
38
9
38
9
3
8
9
389
389
389
389
3
8
9
3
8
9
388
38
8
388
388 388
388
388
388
388
38
8
388
38
8
388
3
8
8
38
8
3
8
8
388
388
388
388
38
8
387
387
387 387
387
387
387
387
387
387
3
8
7
38
7
3
8
7
387
387
387
38
7
3
8
7
387
386
386
386
38638
6
386
386
386
386
38
6
38
6
386
386
3863
8
6
386
3
8
6
385
385
385
385
3
8
5
385
385
385385
3
8
5
3
8
5
38
5
385
385
385
38
5
384
384
384384
384
3
8
4
384
384
384
384
3
8
4
38
4
384
384
384
3
8
4
383383
383
383
383
38
3
383
383
383
383
3
8
3
38
3
38
3
383
383
382
382 382
382
382
382
382 382
382
3
8
2
382
382
382
381
381 381
381
381
381
381 381 381
38
1
381
381
381
380
380
38
0
380
380
380
380 380 380
380
3
8
0
380
380
379
379
37
9
379
379
379
379 379
379
379
37
9
379
3
7
9
378378378
378
378
378
37
8
378378
3
7
8
378
377377
377
377377
377
377
377377
377
376 376 376
376 376
376 376
376
3
7
6
376
375
375 375
375 375
375 375
375
375
37
4
374
374 374
374 374
374 374
374
373
373 373
373
373 373
373
373
372
372
372372
372372372372
371
371
371371
371371371371370370370
370
370
370
3
7
0
370
3
7
0
369 369 369
369 369
369
369
3
6
9
368
36
8
368
368
368368368368
36
7
3
6
7
367
367
367367367367
366 366 366
366
366
366
3
6
6
3
6
6
3
6
6
365 365 365
365
365
365
36
5
36
5
365
364
3
6
4
3
6
4
364
364
364
364364364
3
6
3
3
6
3
3
6
3
363
363363
363
363
363
3
6
2
362
362
362
362
362
362
362
361
3
6
1
36
1
3
6
1
361
361
361361
360
3
6
0
360
360
360
360360
359
3
5
9
35
9
359
359
359
359
35
8
358
358
358
357
357
357
357
357
357
356
356
356
356
356
356
356
390
390
390
391
39
1
39
1
3
9
1
39
1
39
1
39
0
390
390
3
9
0
390
3
9
0
3
9
0
3
9
0
3
8
9
3
8
9
3
8
8
3
8
8
3
8
7
387
38
7
386
D
50' A
N
R
C
L
A
S
S
I
I
W
E
T
L
A
N
D
B
U
F
F
E
R
SPEAR S
T
R
E
E
T
UP
S
W
E
P
T
L
A
N
E
PINNACL
E
D
R
I
V
E
TO
S
P
E
A
R
S
T
R
E
E
T
PARK
S
I
D
E
D
R
STORMWATER DISCONNECTION AREA
STORMWATER DISCONNECTION AREA
2' WIDE PEASTONE DIAPHRAGM FILTER STRIP
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
60 120 180
15
°
±
VT Grid
Magnetic
Stormwater
Overview Plan
C4-01
06/18/2024
1" = 60'
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
STORMWATER LEGEND
NEW IMPERVIOUS IN NOWLAND
FARM RD RIGHT-OF-WAY = 926 SF
NEW IMPERVIOUS ON HUBBARD
PARCEL = 21,523 SF = 0.494 AC
NEW IMPERVIOUS IN UPSWEPT ROW
= 2,583 SF
DESIGNATED STORMWATER
DISCONNECTION AREAS
TOTAL IMPERVIOUS = 25,032 SF OR 0.57 ACRES
UP
UP
UP
UP
UP
UP
D
G
W
W
394
394
3
9
4
394
394
3
9
4
394
39
4
393
393
39
3
393
393
393
393
3
9
3
39
3
3
9
2
392
39
2
39
2
392
392
392
392
39
2
392
392
392
392
39
2
392
392
39
2
3
9
2
39
1
391 39
1
39
1
391
391
391
3
9
1
391
391
391
391
3
9
1
391
391
39
1
391
391
391
391
390
390
390
39
0
390
39
0
390
390
390
390
390
3
9
0
390
390
3
9
0
390
3
9
0
390
390
390
390
390
3
9
0
389
389
389
389
3
8
9
389
389
389
389
389
389
389
38
9
38
9
3
8
9
389
389
389
389
3
8
9
3
8
9
388
38
8
388
388 388
388
388
388
388
38
8
388
38
8
388
3
8
8
38
8
3
8
8
388
388
388
388
38
8
387
387
387 387
387
387
387
387
387
387
3
8
7
38
7
3
8
7
387
387
387
38
7
3
8
7
387
386
386
386
38638
6
386
386
386
386
38
6
38
6
386
386
3863
8
6
386
3
8
6
385
385
385
385
3
8
5
385
385
385385
3
8
5
3
8
5
38
5
385
385
385
38
5
384
384
384384
384
3
8
4
384
384
384
384
3
8
4
38
4
384
384
384
3
8
4
383383
383
383
383
38
3
383
383
383
383
3
8
3
38
3
38
3
383
383
382
382 382
382
382
382
382 382
382
3
8
2
382
382
382
381
381 381
381
381
381
381 381 381
38
1
381
381
381
380
380
38
0
380
380
380
380 380 380
380
3
8
0
380
380
379
379
37
9
379
379
379
379 379
379
379
37
9
379
3
7
9
378378378
378
378
378
37
8
378378
3
7
8
378
377377
377
377377
377
377
377377
377
376 376 376
376 376
376 376
376
3
7
6
376
375
375 375
375 375
375 375
375
375
37
4
374
374 374
374 374
374 374
374
373
373 373
373
373 373
373
373
372
372
372372
372372372372
371
371
371371
371371371371370370370
370
370
370
3
7
0
370
3
7
0
369 369 369
369 369
369
369
3
6
9
368
36
8
368
368
368368368368
36
7
3
6
7
367
367
367367367367
366 366 366
366
366
366
3
6
6
3
6
6
3
6
6
365 365 365
365
365
365
36
5
36
5
365
364
3
6
4
3
6
4
364
364
364
364364364
3
6
3
3
6
3
3
6
3
363
363363
363
363
363
3
6
2
362
362
362
362
362
362
362
361
3
6
1
36
1
3
6
1
361
361
361361
360
3
6
0
360
360
360
360360
359
3
5
9
35
9
359
359
359
359
35
8
358
358
358
357
357
357
357
357
357
356
356
356
356
356
356
356
390
390
390
391
39
1
39
1
3
9
1
39
1
39
1
39
0
390
390
3
9
0
390
3
9
0
3
9
0
3
9
0
3
8
9
3
8
9
3
8
8
3
8
8
3
8
7
387
38
7
386
EX
I
S
T
I
N
G
HO
M
E
,
TY
P
.
EXISTING PARKING AREA (TO
BE REMOVED)
N/FLIANG
W
A
N
T
I
N
G
N/FWILLIA
M
&
J
U
D
I
T
H
M
C
M
E
E
K
I
N
N/FKELLEY
G
A
R
D
N
E
R
T
R
U
S
T
MURALI
D
H
A
R
M
U
L
P
U
R
I
N/FRYAN &
K
I
M
B
E
R
L
Y
P
I
N
K
H
A
M
N/FDALE &
M
A
R
I
E
B
A
U
M
A
N
N/F
THE SOU
T
H
P
O
I
N
T
H
O
M
E
O
W
N
E
R
S
A
S
S
O
C
.
I
N
C
.
N/F
THE SOU
T
H
P
O
I
N
T
H
O
M
E
O
W
N
E
R
S
A
S
S
O
C
.
I
N
C
.
D
50' A
N
R
C
L
A
S
S
I
I
W
E
T
L
A
N
D
B
U
F
F
E
R
SPEAR S
T
R
E
E
T
UP
S
W
E
P
T
L
A
N
E
PINNACL
E
D
R
I
V
E
SCE
SOIL STOCKPILE AREA
TO
S
P
E
A
R
S
T
R
E
E
T
PARK
S
I
D
E
D
R
STABILIZED CONSTRUCTION
ENTRANCE
TREE PROTECTION (TYPICAL)
TREE PROTECTION (TYPICAL)
EXISTING TREES TO REMAIN
VEGETATION TO BE REMOVED
TREE PROTECTION (TYPICAL)INLET PROTECTION
EXISTING TREE TO BE REMOVED (15"DBH)
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
60 120 180
1
5
°
±
VT Grid
Magnetic
Erosion Prevention &
Sediment Control
Plan
C5-01
06/18/2024
1" = 60'
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
PROJECT AREA
SOIL STOCK PILE
SILT FENCE
STABILIZED CONSTRUCTION
ENTRANCE
INLET PROTECTION
SCE
EPSC LEGEND
AREA OF DISTURBANCE = 2.25 ACRES
X
VEGETATION REMOVAL
X
TREE PROTECTION
TREE REMOVAL
G
G
G
W
W
W
W
W
W
W
W
392
392
392
392
39
1
391
391
391
391
390
CLASS III
WETLAND
C
CLASS III
WETLAND
M
CLASS II
WETLAND
A
390
390
391
39
1
39
1
3
9
1
39
1
39
1
3
9
0
3
9
0
3
9
0
EXI
S
T
I
N
G
M
O
W
E
D
G
R
A
S
S
P
A
T
H
PINNACL
E
D
R
I
V
E
0+00
0+50
1+00
1+50
2+00
2+50
3+00
3+50
4+00
4+50
5+00
5+50
392
392
392
392
392
392
392
392
392
392
391
3
9
1
391
391
TC = 392.57
BC = 392.07
+ 391.10
+ 391.10
TC = 392.57
BC = 392.07
TC = 392.30
BC = 391.80
+ 391.39
392
39
2
Horizontal Scale: 1" =10'
Vertical Scale: 1" =1'
P:
3
9
0
.
3
8
E:
3
9
0
.
3
8
P:
3
9
0
.
8
2
E:
3
9
0
.
7
0
P:
3
9
1
.
5
7
E:
3
9
0
.
8
4
P:
3
9
1
.
9
1
E:
3
9
0
.
9
4
P:
3
9
2
.
1
7
E:
3
9
1
.
3
8
P:
3
9
2
.
4
1
E:
3
9
1
.
6
8
P:
3
9
2
.
6
5
E:
3
9
1
.
9
1
P:
3
9
2
.
9
0
E:
3
9
2
.
0
0
P:
3
9
3
.
0
0
E:
3
9
2
.
0
0
P:
3
9
2
.
9
9
E:
3
9
2
.
0
0
P:
3
9
2
.
7
2
E:
3
9
1
.
5
6
P:
3
9
2
.
2
9
E:
3
9
1
.
2
2
PATH PROFILE
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50
384
386
388
390
392
394
396
398
400
0.54%
2.48%
4.20%
0.22%0.00%0.23%0.00%
0.85%
25.00VC
PV
I
S
T
A
.
0
+
1
9
.
2
4
PV
I
E
L
E
V
.
3
9
0
.
5
5
25.00VC
PV
I
S
T
A
.
0
+
4
5
.
6
5
PV
I
E
L
E
V
.
3
9
0
.
6
9
25.00VC
PV
I
S
T
A
.
0
+
7
3
.
2
7
PV
I
E
L
E
V
.
3
9
1
.
3
8
25.00VC
PV
I
S
T
A
.
1
+
0
0
.
0
0
PV
I
E
L
E
V
.
3
9
2
.
5
0
25.00VC
PV
I
S
T
A
.
1
+
4
6
.
4
5
PV
I
E
L
E
V
.
3
9
2
.
6
0
25.00VC
PV
I
S
T
A
.
2
+
0
0
.
0
0
PV
I
E
L
E
V
.
3
9
2
.
6
0
50.00VC
PV
I
S
T
A
.
3
+
7
0
.
6
9
PV
I
E
L
E
V
.
3
9
3
.
0
0
50.00VC
PV
I
S
T
A
.
4
+
6
6
.
5
3
PV
I
E
L
E
V
.
3
9
3
.
0
0
EXISTING GRADE
FINISHED GRADE
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
20 40 60
15
°
±
VT Grid
Magnetic
Plan & Profile Plan
C6-01
06/18/2024
1" = 100'
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
1
0
0
'
W
E
T
L
A
N
D
B
U
F
F
E
R
394
394
393
393
39
2
392
392
39
2
39
1
391
CLASS III
WETLAND
C
CLASS III
WETLAND
F
CLASS III
WETLAND
M
CLASS III
WETLAND
L
5+50
6+00
6+50
7+00
7+50
8+00
8+50
9+00
9+5
0
10
+
0
0
10+50
11+00
11+50
BIKE RACK
6' BENCHES
CONCRETE PADS
NEW 10' WIDE SHARED USE PATH
NEW 10' WIDE MOWED GRASS PATH
E
X
I
S
T
I
N
G
M
O
W
E
D
G
R
A
S
S
P
A
T
H
394
394
39
4
39
4
393
393393
393
393
393 393
393
392
392
392
392
392
392
STORMWATER DISCONNECTION AREA
5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00
E:
3
9
1
.
2
2
P:
3
9
2
.
1
7
E:
3
9
1
.
0
0
P:
3
9
2
.
6
5
E:
3
9
1
.
5
0
P:
3
9
2
.
9
5
E:
3
9
2
.
0
0
P:
3
9
3
.
0
2
E:
3
9
2
.
0
0
P:
3
9
3
.
1
1
E:
3
9
2
.
0
4
P:
3
9
3
.
4
5
E:
3
9
2
.
3
2
P:
3
9
3
.
9
2
E:
3
9
2
.
6
3
P:
3
9
4
.
4
0
E:
3
9
3
.
2
0
P:
3
9
4
.
8
3
E:
3
9
3
.
8
6
P:
3
9
4
.
9
0
E:
3
9
4
.
0
0
P:
3
9
4
.
8
9
E:
3
9
4
.
0
0
0.99%
0.15%
0.95%
50.00VC
PV
I
S
T
A
.
5
+
8
4
.
0
7
PV
I
E
L
E
V
.
3
9
2
.
0
0
50.00VC
PV
I
S
T
A
.
6
+
7
6
.
3
0
PV
I
E
L
E
V
.
3
9
2
.
9
1
50.00VC
PV
I
S
T
A
.
8
+
1
5
.
5
4
PV
I
E
L
E
V
.
3
9
3
.
1
2
50.00VC
PV
I
S
T
A
.
1
0
+
0
3
.
6
1
PV
I
E
L
E
V
.
3
9
4
.
9
1
Horizontal Scale: 1" =10'
Vertical Scale: 1" =1'
384
386
388
390
392
394
396
398
400
PATH PROFILE
EXISTING GRADE
FINISHED GRADE
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
20 40 60
15
°
±
VT Grid
Magnetic
Plan & Profile Plan
C6-02
06/18/2024
1" = 60'
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
D
D
D D
G
G
G
G
G
W
W
W W W
394
3
9
4
394
393
3
9
3
3
9
2
392
39
2
3
9
1
391
391
390
390
390
3
9
0
389
389
38
9
388
38
8
388
3
8
8
38
7
387
38
6
EXISTING HOME, TYP.
D
D
D
D
D
D
D
REMOVE EX. CONCRETE SIDEWALK. CONTRUCT NEW
C
U
R
B
R
A
M
P
WITH DETECTABLE WARNING SURFACE
CLASS II
WETLAND
CONC
R
E
T
E
S
I
D
E
W
A
L
K
CO
N
C
R
E
T
E
S
I
D
E
W
A
L
K
EXISTING SIGHT
DISTANCE EASEMENT
NEW CROSSWALK
11+00
11+50
12+00
12+50
13+00
13+50
14+00
14+50
15+00
15+50
REMOVE EXISTING CONCRETE
SIDEWALK. CONSTRUCT NEW CURB
RAMP AND DETECTABLE WARNING
SURFACE, GRADED EARTH STYLE
SEE DETAIL
NEW 10' WID
E
S
H
A
R
E
D
U
S
E
P
A
T
H
REMOVE
EXISTING
BOARDWALK
80' ROW
BIKE RACK
NEW 10' WIDE MOWED GRASS PATH
PARK
S
I
D
E
D
R
EXISTING UTILITY
EASEMENT
394
393
393
392
392
391
391
39
1
391
390
3
9
0
389
389
388
388
388
SIGN:
PEDESTRIAN CROSSING (W11-2)
15" HDPE
6' BENCH
STORMWATER DISCONNECTION AREA
X
11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50
384
386
388
390
392
394
396
398
400
P:
3
9
4
.
8
9
E:
3
9
4
.
0
0
P:
3
9
4
.
8
7
E:
3
9
4
.
0
0
P:
3
9
4
.
8
6
E:
3
9
4
.
0
0
P:
3
9
4
.
7
6
E:
3
9
4
.
0
0
P:
3
9
3
.
6
1
E:
3
9
2
.
3
4
P:
3
9
2
.
3
1
E:
3
9
1
.
2
3
P:
3
9
1
.
6
6
E:
3
9
0
.
5
9
P:
3
9
1
.
0
5
E:
3
9
0
.
0
0
P:
3
8
9
.
7
6
E:
3
8
9
.
0
0
P:
3
8
8
.
1
3
E:
3
8
8
.
0
0
E:
3
8
6
.
5
8
0.03%
2.93%
1.18%
3.26%
50.00VC
PV
I
S
T
A
.
1
2
+
5
7
.
8
7
PV
I
E
L
E
V
.
3
9
4
.
8
4
50.00VC
PV
I
S
T
A
.
1
3
+
4
4
.
4
4
PV
I
E
L
E
V
.
3
9
2
.
3
1
50.00VC
PV
I
S
T
A
.
1
4
+
6
5
.
7
0
PV
I
E
L
E
V
.
3
9
0
.
8
8
50.00VC
PV
I
S
T
A
.
1
5
+
5
1
.
1
0
PV
I
E
L
E
V
.
3
8
8
.
1
0
Horizontal Scale: 1" =10'
Vertical Scale: 1" =1'
PATH PROFILE
EXISTING GRADE
FINISHED GRADE
15" HDPE
382
380
ASSUMED LOCATION AND DEPTH OF EXISTING 12" DI WATER MAIN
378
ASSUMED LOCATION AND DEPTH OF EXISTING 12" HDPE STORM PIPE Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
20 40 60
15
°
±
VT Grid
Magnetic
Plan & Profile Plan
C6-03
06/18/2024
SHOWN
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
UP
S
W
E
P
T
L
A
N
E
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
Site Details
C8-01
06/18/2024
Shown
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
BITUMINOUS CONCRETE PAVEMENT TO BE
SUPERPAVE TYPE IVS (PAY ITEM 406.35)
THICKNESS TOLERANCES:
PAVEMENT - ±1/4" TOTAL DEPTH
SUBBASE - ±1" TOTAL DEPTH
1.ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE VERMONT
AGENCY OF TRANSPORTATION STANDARD SPECIFICATIONS FOR
CONSTRUCTION 2018 AND ITS LATEST REVISIONS, THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (2009 EDITION) AND THESE PLANS.
2.THE CONTRACTOR SHALL CONTACT ALL UTILITIES BEFORE EXCAVATION TO
VERIFY THE LOCATION OF ANY UNDERGROUND LINES. THE CONTRACTOR
SHALL NOTIFY "DIGSAFE" AT 811 PRIOR TO ANY EXCAVATION. PRIOR TO
CALLING DIG SAFE IT IS A REQUIREMENT TO PREMARK PROPOSED EXCAVATION
AREAS USING WHITE PAINT, STAKES OR OTHER SUITABLE WHITE MARKINGS, IN A
MANNER THAT WILL ENABLE THE OPERATORS OF THE UNDERGROUND UTILITY
FACILITIES TO KNOW THE BOUNDARIES OF THE PROPOSED EXCAVATION
ACTIVITIES. PRE MARKING IS NOT REQUIRED IF THE ACTUAL EXCAVATION WILL
BE CONTINUOUS AND WILL EXCEED 500 FEET IN LENGTH.
3.UTILITIES INFORMATION SHOWN ON THE PLANS WAS OBTAINED FROM BEST
AVAILABLE SOURCES AND MAY OR MAY NOT BE EITHER ACCURATE OR
COMPLETE. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EXISTING
UTILITIES AND SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ANY UTILITY,
PUBLIC OR PRIVATE, SHOWN OR NOT SHOWN HEREON. CONTRACTOR SHALL
CONNECT OR RECONNECT ALL UTILITIES TO THE NEAREST SOURCE THROUGH
COORDINATION WITH UTILITY OWNER.
4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION AND REMOVAL
OF ALL EXISTING VEGETATION, PAVEMENT AND STRUCTURES NECESSARY TO
CONSTRUCT THIS PROJECT UNLESS OTHERWISE NOTED ON THESE PLANS. THE
CONTRACTOR SHALL REMOVE ALL EXCESS MATERIAL, DEBRIS AND TRASH
FROM THE SITE UPON COMPLETION OF CONSTRUCTION.
5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT THE DUST
CREATED AS A RESULT OF CONSTRUCTION DOES NOT CREATE A NUISANCE OR
A SAFETY HAZARD. WHERE AND WHEN DEEMED NECESSARY BY THE
LANDSCAPE ARCHITECT / ENGINEER, THE CONTRACTOR SHALL BE REQUIRED
TO WET SECTIONS OF THE CONSTRUCTION AREA WITH WATER, APPLY CALCIUM
CHLORIDE, OR SWEEP THE ROADWAY AND / OR DRIVEWAYS.
6.ANY SURFACES, LINES, MARKERS OR STRUCTURES WHICH HAVE BEEN
DAMAGED BY THE CONTRACTOR'S OPERATIONS SHALL BE RESTORED BY THE
CONTRACTOR AT HIS OR HER EXPENSE, TO THE CONDITION AT LEAST EQUAL TO
THAT IN WHICH THEY WERE FOUND IMMEDIATELY PRIOR TO THE BEGINNING OF
OPERATIONS.
7.TO ENSURE COMPLIANCE WITH THE PLANS AND OTHER REQUIREMENTS, THE
DESIGN ON THESE PLANS SHALL BE INSPECTED BY TRUDELL CONSULTING
ENGINEERS, INC. (TCE), WILLISTON, VERMONT. TCE WAIVES ANY AND ALL
RESPONSIBILITY AND LIABILITY FOR PROBLEMS THAT MAY ARISE FROM THE
FAILURE OF THE CONTRACTOR TO FOLLOW THESE PLANS, SPECIFICATIONS AND
THE DESIGN INTENT THAT THE PLANS CONVEY, AND FROM THE FAILURE TO
HAVE BEEN RETAINED OR NOTIFIED TO INSPECT THE WORK AND TESTS IN
PROGRESS. AT A MINIMUM, THE CONTRACTOR SHALL NOTIFY THE ENGINEER 24
HOURS IN ADVANCE OF STARTING ANY WORK, CUTTING THE PAVEMENT,
BEGINNING THE INSTALLATION OF ANY UTILITIES, PRIOR TO BRINGING IN ANY
NEW GRAVEL FOR THE NEW BASE, TO VERIFY LEDGE BLASTING AND REMOVAL,
PAVING AND SIGNALS TO VERIFY QUANTITIES, AND FINAL INSPECTION.
GENERAL CONSTRUCTION NOTES
C
PROVIDE MINIMUM TOP AND SIDE CLEARANCE TO BRANCHES, WIRES,
POLES, FENCES, SIGNS, OR OTHER OBSTRUCTIONS: 10 FT VERTICAL
ABOVE PATH, 8 FT HORIZONTAL FROM PATH CENTERLINE
L
15" CRUSHED GRAVEL SUBBASE
(COARSE GRADED)
4" TOPSOIL AND
GRASS COVER (TYP.)2'2'
2" BITUMINOUS
CONCRETE
S = 16% MAX.
1
4
S = 2% MAX.
S = 16% MAX.
SHARED-USE PATH TYPICAL SECTION
NTS
EARTH BORROW
(TYP.)
5'5'
CL
4
114
12
"
12"
(CUT SECTION)
EXISTING GROUND
MATCH EXISTING
GRADE
(FILL SECTION)
S = 2% MAX.
(6) #8 REBAR VERTICAL, EVENLY
SPACED
#4 REBAR CIRCULAR - 10" O.C.
3"
(4) 1/2" X 24" GALVANIZED BENT
ANCHOR BOLT W/ 3" HOOK
1'-8"20" Ø ROUND CONCRETE FOOTING: HIGH
PERFORMANCE CONCRETE, CLASS B (4000 PSI AT
28 DAYS)
CONCRETE FOOTING PLAN
5"
COMPACTED SUBGRADE
4'-6"
3'-1"9"
1'-2"
(2) 4"X6" POSTS SANDWICHED AND BOLTED TOGETHER, NOTCHED TO
RECEIVE BEAM AND PANEL.
8"6"
4"X8" BEAM, NOTCHED TO RECEIVE RAFTERS,
ROUTED TO RECEIVE PANEL BELOW
2"X7" RAFTERS, NOTCHED TO FIT OVER BEAM
STEEL POST ANCHOR (1/2" THICK VERTICAL PLATE, WELDED TO 1/2" THICK
12" x 12" STEEL BASE PLATE) INTERNAL TO POST, THROUGH-BOLTED.
BOLT TO ANCHOR BOLTS WITH LEVELLING NUTS
(2) 1/2" EXTERIOR PLYWOOD SHEETS SCREWED AND GLUED,
SCREWED TO RAFTERS (12" O.C.) FACED WITH GALVANIZED SHEET
METAL ON TOP AND UNDERSIDE (GLUED). TOP SHEET TO WRAP
OVER SIDES, WRAP UP POST AND INSTALL ALUMINUM FLASHING
ALUMINUM 'L' FASCIA SCREWED TO UNDERSIDE OF ROOF, ALL SIDES
(1' O.C., SS SCREWS), SEAL TOP SEAM WITH CLEAR EXTERIOR GRADE
SILICON CAULK. FASCIA ON LONG SIDES OF ROOF TO EXTEND 1/2"
ABOVE TOP PANEL (WATER TO DRAIN OFF SHORT SIDES)
GALVANIZED STEEL SUPPORT ROD, WITH
CONNECTORS THROUGH-BOLTED THROUGH
ROOF AND POST
NOTES:
1.UNLESS OTHERWISE NOTED, ALL STEEL
COMPONENTS TO BE HOT-DIP GALVANIZED.
2.ALL BOLTS, SUPPORT RODS, AND
STRUCTURAL COMPONENTS SHALL BE
SIZED TO ADDRESS WIND AND SNOW LOADS.
3.ALL LUMBER TO BE WHITE OAK
(FULL-DIMENSIONAL).
4.CONTRACTOR TO PROVIDE SHOP DRAWINGS
FOR LANDSCAPE ARCHITECT REVIEW AND
APPROVAL PRIOR TO CONSTRUCTION.
ELEVATION VIEW
SECTION VIEW
ROOF PLAN
STONE DUST SURFACE -
SEE B/L3.00
1" THICK EXTERIOR BLACK MDO
PANELS (GRAPHIC PANELS TO BE
INSTALLED BY OTHERS AT FUTURE
DATE)
TYP.
5/8" GALVANIZED BOLTS AND WASHERS,
COUNTERSUNK, TYP.
5'-2"
1'-2"
3"3"
2"
SECTION VIEW
1/2" = 1'-0"
TRUDELL CONSULTING ENGINEERS
INFORMATION KIOSK
3'-
1
1
"
9'
-
1
1
"
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
Site Details
C8-02
06/18/2024
SHOWN
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
MS-050.1.1LAST REVISED 02/10/2021TRUDELL CONSULTING ENGINEERS
TYPICAL CROSSWALK MARKING
SPACING NOT TO EXCEED TWICE STRIPING WIDTH
WI
D
T
H
O
F
R
O
A
D
6'-8'
REFLECTIVE WHITE STRIPING
PER MUTCD
SPACE STRIPING TO AVOID WHEEL PATH
18" - 24"
SD 010.3.1LAST REVISED 03/04/2021TRUDELL CONSULTING ENGINEERS
TYPICAL BITUMINOUS PAVEMENT
NOTES:
1.SUBBASE, SAND CUSHION AND SUBGRADE SHOULD BE CONSTRUCTED AND COMPACTED TO THE DIMENSIONS SHOWN IN
ACCORDANCE WITH VERMONT AGENCY OF TRANSPORTATION SPECIFICATIONS, STANDARD A-76. WHERE MORE STRINGENT
LOCAL ORDINANCES HAVE BEEN ADOPTED RELATIVE TO ROAD DIMENSIONS AND CONSTRUCTION, THEY SHOULD GOVERN.
2.COMPACT ALL SUBBASE MATERIALS TO 95% MAXIMUM DENSITY (STANDARD PROCTOR).
3.IF GROUNDWATER OR SOFT SPOTS ARE ENCOUNTERED CONTACT THE ENGINEER TO DISCUSS ADDED MEASURES SUCH AS
UNDERDRAIN OR MORE SUBBASE MATERIALS. SLOPE SUBBASE TO UNDERDRAIN LOW POINTS.
SECTION
WEARING COURSE (TYPE III) (VAOT 406)
IF DELAYED, DISCUSS WITH ENGINEER
ADDITIONAL MEASURES TO INCLUDE
SWEEPING ROADWAY AND EMULSIFIED
ASPHALT
BASE COURSE (TYPE II) (VAOT 406)
CRUSHED GRAVEL (VAOT 704.05A FINE)
GRAVEL BASE (VAOT 704.04) OR
CRUSHED GRAVEL (VAOT 704.05A
COARSE)
MIRAFI 500X STABILIZATION FABRIC
INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS
6" SAND BORROW AND CUSHION TO BE
USED IN POORLY DRAINED SOILS OR
OVER BEDROCK FOR ROADS AND
SIDEWALKS (VAOT 703.03)
UNDISTURBED SUBGRADE
OR COMPACTED FILL
A
B
C
D
E
1" = 1'
DRIVEWAYS
E 6 66 66
RESIDENTIAL COMMERCIAL
1 1/2
6
18
2 1/2
4
12
N/A
2
3
18
6
COMMERCIAL
2
PRIVATEROADS
THICKNESS (INCHES)
PARKING LOTS
1
2
12
6
1-1/2
2-1/2
12
6
RESIDENTIAL
D
B
C
A
SD 050.2.1LAST REVISED 03/11/2021TRUDELL CONSULTING ENGINEERS
BIKE RACK
36"
47
"
35
"
#4 REBAR 24"
O.C. BOTH WAYS
6"
18
"
6" PORTLAND CEMENT
PAD CLASS "A" CONCRETE
2X 0.25" X 12.75" ANCHOR RODS
18" CRUSHED STONE WRAPPED
IN 140N GEOTEXTILE FABRIC UNDISTURBED SOIL
6" P2 3/8" O.D.
GALVANIZED STEEL
SCHEDULE 40 PIPE WITH
POWDERCOAT FINISH
BLACK
NOTE:
SEE SITE PLAN FOR SIZE AND
LOCATION.
FINISHED GRADE
SD 050.2.2TRUDELL CONSULTING ENGINEERS
BIKE RACK LAYOUT
30"
O.C.
SE
E
S
I
T
E
P
L
A
N
30
"
24"
30
"
24"
SEE SITE PLAN
CONCRETE PAD
BIKE RACK LOOP - INVERTED U
NOTES:
1.OVERALL CONCRETE PAD WIDTH WILL VARY BASED ON NUMBER OF LOOPS.
2.1 LOOP = 2 BICYCLE PARKING SPACES.
3.SEE SITE PLAN FOR SIZE AND LOCATION.
LAST REVISED 03/03/2021
SD 010.7.1LAST REVISED 03/09/2021TRUDELL CONSULTING ENGINEERS
APBA PARKING GUIDELINE PLAN VIEW
72"
24"
48"
(36" min)
96" RECOMMENDED TO OBSTRUCTION
(36" PREFERRED WHEN
ADJACENT TO AUTO
PARKING)
BIKE RACK
SD 020.X.XLAST REVISED 12/26/2023TRUDELL CONSULTING ENGINEERS
SIDEW
A
L
K
1.5% M
A
X
.
C
R
O
S
S
W
A
L
K
BUFFER ZONE
7.
5
%
M
A
X
.
RAMP
SIDEWALK AND CURB RAMP DETAIL
GRADED EARTH - SIDE CONFIGURATION
SD 020.X.XLAST REVISED 12/26/2023TRUDELL CONSULTING ENGINEERS
SIDEWALK AND CURB RAMP CONFIGURATION: TYPE 2
4'-0"
M
I
N
.
SIDEW
A
L
K
1.5%
M
A
X
.
C
R
O
S
S
W
A
L
K
NOTE:
1.BEYOND THE BOTTOM GRADE BREAK, A CLEAR SPACE OF 4'-0" x 4'-0" MINIMUM
SHALL BE PROVIDED WITHIN THE WIDTH OF THE PEDESTRIAN CROSSWALK, AND
OUTSIDE THE PARALLEL VEHICLE TRAVEL LANE. THE CLEAR SPACE MAY OVERLAP
TURNING SPACES, DETECTABLE WARNING SURFACES, AND DROP CURBS.
7.5
%
M
A
X
.
RAMP
DETECTABLE WARNING
(SEE DETAIL)
CLEAR SPACE
(SEE NOTE)
44 1
4 "
18 12 "
NTS
TRUDELL CONSULTING ENGINEERS
TYPICAL LUMINAIRE
GRASS AREAS
PAVED AREAS
A:MOUNT HEIGHT VARIES.
B:BASE DEPTH 6 FT. MIN.
FOR UP TO 20 FT. MOUNT HEIGHT. 8
FT. MIN. FOR UP TO 30 FT.
C:PRECAST FOOTING DIAMETER
DETERMINED BY BASE PLATE
D:SUBMIT SHOP DRAWINGS FOR
REVIEW PRIOR TO CONSTRUCTION.
NOTE:
BOLT PATTERN, CONDUIT SIZE AND
GROUNDING TO BE DETERMINED BY
LIGHTING/ELECTRIC CONTRACTOR
B
℄
24
"
A
MO
U
N
T
H
E
I
G
H
T
V
A
R
I
E
S
C
B
HADCO VX600
PAINT EXPOSED FOOTING YELLOW
4"
CLASS B CONCRETE FOOTING
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
E N G I N E E R I N G S U R V E Y
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E
SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLANNIN G ENVIRON MENTAL
Site Details
C8-03
06/14/2024
SHOWN
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
1 06/14/24 AADCulvert
SD 030.2.1LAST REVISED 03/03/2021TRUDELL CONSULTING ENGINEERS
WARNING TEXTURE
NOTES:
1.PER MUNICIPAL REQUIREMENTS PROVIDE CAST IRON
TRUNCATED DOME PAD.
2.SEE SITE PLAN FOR LOCATION.
ASPHALT
ASPHALT SURFACES SHALL BE COMPOSED OF OIL BASED BITUMEN. COAL TAR ASPHALT IS NOT ACCEPTABLE,
NOR WARRANTED. ASPHALT MUST CURE MINIMUM 20 DAYS PRIOR TO INSTALLATION TO INSURE PROPER
BONDING OF ALL SURFACES. THIS ALLOWS TENSILE STRENGTH PROPERTIES OF BOTH MATERIALS TO MORE
CLOSELY APPROXIMATE EACH OTHER. ANY ASPHALT AREAS REQUIRING DETECTABLE WARNING INSTALLATIONS
SHALL BE COMPACTED WITH VIBRATORY ROLLERS OR APPROVED COMPACTION EQUIPMENT IN ADDITION TO
STANDARD LOCAL CONDITIONS TO PROVIDE MAXIMUM COMPACTION OF ASPHALT ALLOWING THE
GREATEST ADHESION.
SEAL COAT
PRODUCT SHALL NOT BE PLACED ON ASPHALT OR COAL TAR SEALERS. IF SURFACE HAS BEEN SEALED, GRIND
ENTIRE AREA TO BE INSTALLED TO REMOVE ALL SEALERS.
CONCRETE
MINIMUM COMPRESSIVE STRENGTH 3000 PSI. CONCRETE MUST CURE FOR 15 DAYS PRIOR TO INSTALLATION TO
INSURE PROPER BONDING. ALL CONCRETE COLORING/ADDITIVES SHALL BE INTEGRAL, NOT SURFACE APPLIED.
ALL "SURFACE CURING" COMPOUNDS OR SEALERS SHALL BE REMOVED BY METHOD OF GRINDING ON ANY
CONCRETE THAT IS LESS THAN 6 MONTHS OLD BEFORE PRODUCTS ARE INSTALLED. SURFACE FINISH SHOULD BE
MEDIUM BROOM FINISH FOR MAXIMUM ADHESION.
SURFACES
ALL SURFACES TO BE CLEAN AND DRY. TRUNCATED DOMES AND ALL RELATED INSTALLED SURFACES TO BE
INSTALLED ACCORDING TO MANUFACTURERS SPECIFICATIONS. ALL DETECTABLE WARNING SURFACE
INSTALLATIONS SHALL BE AT MINIMUM, AT LEAST AS NON SKID AS THE SURROUNDING PEDESTRIAN SURFACES.
MIN.
CAST IRON TRUNCATED
DOME
DETECTABLE WARNING
DETAIL
G
ELEVATION
F
0.2"
G 1.40".90"
F .80".45"
E 1.50".65"
D
MAX.
2.40"
PLAN
1.60"
E
D
D
E
RAMP
EDGE OF PAVEMENT
NO CURB
CAST IRON TRUNCATED
DOMES. SEE SITE PLAN
FOR LOCATION(S).
24"
SIDEWALK
SD 010.5.3LAST REVISED 03/02/2021TRUDELL CONSULTING ENGINEERS
PAVEMENT JOINT DETAIL WITH COLD PLANE
30"
1-1/2" TYPE III OVERLAY
1-1/2" TYPE III
3" TYPE II
6"
18"
EXISTING SURFACE
EXISTING PAVEMENT
MATCH EXISTING HIGHWAY BASE DEPTH
EXISTING BASE
(ASSUME 24" DEPTH)
(ASSUME 5" DEPTH)
COLD PLANESA
W
C
U
T
FINE-GRADED CRUSHED GRAVEL
DENSE-GRADED CRUSHED STONE
COAT WITH EMULSIFIED ASPHALT
COMPACT BACKFILL SAME
MATERIAL AS REMOVED IN 6" LIFTS
TO 95% STANDARD PROCTOR
NEW PAVEMENT TYPE AND THICKNESS UNLESS
INDICATED OTHERWISE ON SITE PLAN
SD 020.1.6
1" = 1'
LAST REVISED 03/08/2021TRUDELL CONSULTING ENGINEERS
TYPICAL CURB DETAIL
SLOPE
BITUMINOUS PAVEMENT
SEE SECTION DETAIL
CONCRETE CURB CLASS B CONCRETE
GRAVEL BASE
CRUSHED GRAVEL
MIRAFI 500X FILTER FABRIC
6"
R1"
18"
6" TOPSOIL
12" CRUSHED GRAVEL
7" REVEAL
SAND BORROW
2"
12"
9"
PRIOR TO PAVING, COAT CONTACT
AREA WITH EMULSIFIED ASPHALT
NOTES:
1.CURBING SHALL BE
CONSTRUCTED IN 10' SECTIONS
WITH 1/8" JOINT BETWEEN
SECTIONS.
2.CURBING EXPANSION JOINTS
SHALL BE INSTALLED EVERY 20'
(1/2" SPONGE RUBBER OR CORK).
3.ALL CONCRETE SHALL BE AIR
ENTRANCED NOT LESS THAN 5%
OR MORE THAN 7%).
4.SLIP FORMING SHALL NOT BE
USED IN CURB CONSTRUCTION.
W11-2
TAPCO
RRFB-XL
OR EQUIVALENT
R10-25
PUSH BUTTON TO
TURN ON WARNING LIGHTS
W16-7P
TRUDELL CONSULTING ENGINEERS
PEDESTRIAN CROSSING WITH RRFB
MS-010.1.4
1" = 1'
LAST REVISED 02/10/2021TRUDELL CONSULTING ENGINEERS
"RESERVED PARKING" "VAN ACCESSIBLE" SIGN
CONCRETE SETTING
(OPTIONAL)
FINISH GRADE
"BREAK-AWAY" STYLE
SIGN POST (STEEL)
R7-8a 12"x6"
(VAN SPACE ONLY)
6"
5'
3'
-
0
"
M
I
N
.
18
"
12"
R7-8 12"x18"
BLUE
GREEN
GREEN
1"
MS-010.1.4
1" = 1'
LAST REVISED 02/10/2021TRUDELL CONSULTING ENGINEERS
"RESERVED PARKING" SIGN
CONCRETE SETTING
(OPTIONAL)
FINISH GRADE
"BREAK-AWAY" STYLE
SIGN POST (STEEL)
3'
-
0
"
M
I
N
.
18
"
12"
R7-8 12"x18"
BLUE
GREEN
GREEN
L-029
1" = xx'
LAST REVISED 02/26/2020TRUDELL CONSULTING ENGINEERS
TREE PROTECTION
FOR TREES TO REMAIN WITHIN LIMIT OF LANDSCAPE
WORK AREA:
CONTRACTOR SHALL CONTACT ARBORIST PRIOR TO
DEMOLITION TO PERFORM RECOMMENDED TREATMENTS(FERTILIZER, ROOT PRUNE, ETC.) ON SPECIMEN TREES TO
REMAIN BEFORE BEGINNING DEMOLITION.
PLAN VIEW
EXISTING
TREE
EXISTINGTREE
6' MIN.
SECTION VIEW
PRUNE PER ISA STANDARDS. REMOVE DEAD &
DAMAGED BRANCHES. TIE BRANCHES UP TO
AVOID DAMAGE FROM CONSTRUCTION
EQUIPMENT.
EXISTING TREE (S)
LI
M
I
T
O
F
D
R
I
P
L
I
N
E
(V
A
R
I
E
S
)
WOODEN OR METAL POSTS (TYPICAL)
INSTALL FENCING AT EDGE OF DRIPLINE OR AS FAR
FROM TRUNK AS POSSIBLE. MIN. DISTANCE IS 6' FROM
TRUNK. MAY BE PLASTIC SNOW FENCE OR CHAIN
LINK, MIN. 4' HIGH.
ZONE OF CONSTRUCTION IMPACT (CUT/FILL)
PRUNE DAMAGED OR EXPOSED
ROOTS DAMAGED WITH A SHARP
SAW.
LIMIT OF FENCING
(INDIVIDUAL TREE)
LIMIT OF FENCING (MULTIPLE TREES)
EXISTING GRADE
LIMIT OF CONSTRUCTION IMPACT (REFER TO PLANS)
LIMIT OF FENCE (INDIVIDUAL TREE)
LIMIT OF
CANOPY
(VARIES)
LIMIT OF FENCING
(MULTIPLE TREES)
WOODEN OR METAL POSTS (MAX. 8' SPACING)
2x4 DIM. LUMBER ATTACHED W/METAL
STRAPPING (OPT) AT 2 LOCATIONS
(MIN.). CLADDING SHALL BE 8' HIGH
WITH 6" SPACING OF BOARDS. WRAP
BARK W/BURLAP PRIOR TO
ARMORING, OR APPROVED
ALTERNATIVE METHOD
NO STORAGE OF EQUIPMENT OF
MATERIALS WITHIN DRIPLINE
SW 020.2.1
1/2"=1'
LAST REVISED 03/15/2021TRUDELL CONSULTING ENGINEERS
POLYETHYLENE (HDPE) END SECTION
ELEVATION VIEW
"D"
POLYETHYLENE FLARED END SECTION,
POLYETHYLENE FLARED END SECTION,
SITE PLAN
SLOPE AS PER
SIDES OF END SECTION
TO MATCH TAPERED
FINISHED GRADE
ADS OR EQUAL.
PLAN VIEW
ADS OR EQUAL.
SITE PLAN
SLOPE AS PER
INLET
CONDITION
OUTLET
CONDITION
OUTLET
CONDITION
INLET
CONDITION
"16"
MINIMUM AREA 5' WIDE x 20' LONG
PROVIDE 18" TYPE II RIPRAP
OVER 12" TYPE P204 RIPRAP
UNLESS INDICATED OTHERWISE
SMOOTH INTERIOR, CORRUGATED EXTERIOR, HIGH
DENSITY POLYETHYLENE PIPE (HDPE). ADVANCED
DRAINAGE SYSTEMS (ADS) N-12 OR EQUA.
"12" min. cover
392
392
392
392
391
391
391
391
391
390
390
389
390
390
391
39
1
39
1
3
9
1
39
1
391
3
9
0
3
9
0
3
9
0
3
8
8
PINNACL
E
D
R
I
V
E
SEED MIX 1:
URBAN CONSERVATION MIX
(TOTAL 35,784 SQ FT)
EXISTING EVERGREEN TREE TO BE RETAINED AND PROTECTED (TYPICAL)
(20) VT
SEED MIX 2:
VERMONT CONSERVATION MIX
(TOTAL 28,702 SQ FT)
EXISTING DECIDUOUS STREET TREE TO REMAIN
EXISTING EVERGREEN TREES TO REMAIN
STONE LANDSCAPE WALL (TYPICAL)
STONE LANDSCAPE
WALL (TYPICAL)
394
394
393
393
39
2
392
392
39
1
(3) QB
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
Landscape Plan
LA 1-01
06/14/2024
SHOWN
22-512
JLA
AAD
LET
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
MA
T
C
H
L
I
N
E
S
E
E
L
A
1
-
0
2
MA
T
C
H
L
I
N
E
S
E
E
L
A
1
-
0
1
B
MA
T
C
H
L
I
N
E
S
E
E
L
A
1
-
0
1
A
A
B
KEY
SEED MIX 1: URBAN CONSERVATION MIX
SEED MIX 2: VERMONT CONSERVATION MIX
TREE PROTECTION FENCE
PARK
S
I
D
E
D
R
EXISTING EVERGREEN TREE TO BE PROTECTED (TYPICAL)
SEED MIX 1:
URBAN CONSERVATION MIX
(TOTAL 35,784 SQ FT)
SEED MIX 2:
VERMONT CONSERVATION MIX
(TOTAL 28,702 SQ FT)
PARK
S
I
D
E
D
R
EXISTING VEGETATION TO BE TRIMMED
SEE C-501
TREE PROTECTION (TYPICAL)
EXISTING RESIDENTIAL LANDSCAPING
TO BE PROTECTED AND REMAIN
(4) PG
KEY
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
20 40 60
15
°
±
VT Grid
Magnetic
Landscape Plan
LA 1-02
06/14/2024
SHOWN
22-512
JLA
AAD
LET
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
MA
T
C
H
L
I
N
E
S
E
E
L
A
2
-
0
1
PLANTING NOTES
1.IF DISCREPANCIES EXIST BETWEEN THE NUMBER OF PLANTS DRAWN ON THE PLANTING PLAN AND THE NUMBER OF PLANTS IN THE
PLANT LIST, THE PLANTING PLAN SHALL GOVERN.
2.ALL NEW PLANT MATERIAL SHALL CONFORM TO THE MINIMUM GUIDELINES ESTABLISHED FOR NURSERY STOCK PUBLISHED BY THE
AMERICAN ASSOCIATION OF NURSERYMEN, INC.
3.ALL NEW PLANTS TO BE BALLED AND BURLAPPED OR CONTAINER-GROWN, UNLESS OTHERWISE NOTED ON THE PLANT LIST.
4.THE CONTRACTOR SHALL SUPPLY ALL NEW PLANT MATERIAL IN QUANTITIES SUFFICIENT TO COMPLETE THE PLANTING SHOWN ON
THE DRAWINGS.
5.ANY PROPOSED SUBSTITUTIONS OF PLANT SPECIES SHALL BE MADE WITH PLANTS OF EQUIVALENT OVERALL FORM, HEIGHT,
BRANCHING HABIT, FLOWER, LEAF, COLOR, FRUIT AND CULTURE, AND ONLY AFTER WRITTEN APPROVAL OF THE LANDSCAPE
ARCHITECT.
6.ALL NEW PLANTS MAY BE TAGGED AND APPROVED BY THE LANDSCAPE ARCHITECT AT THE NURSERY PRIOR TO DIGGING OR
DELIVERY TO THE SITE.
7.CONTRACTOR SHALL LOCATE AND VERIFY ALL EXISTING UTILITY LINES PRIOR TO PLANTING AND SHALL REPORT ANY CONFLICTS
TO THE LANDSCAPE ARCHITECT.
8.STAKE LOCATION OF ALL PROPOSED PLANTING FOR APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO THE COMMENCEMENT OF
PLANTING.
9.NEW SHRUBS AND GROUND COVER SHALL BEAR THE SAME RELATIONSHIP TO GRADE AS IT BORE TO PREVIOUS GRADE. TREES
SHALL BE SET 3" HIGHER THAN PREVIOUS GRADE. NO TREES SHALL BE PLANTED BEFORE ACCEPTANCE OF ROUGH GRADING.
10.ALL PLANT BEDS SHALL RECEIVE FOUR INCHES (3") OF BARK MULCH.
11.ALL EXISTING TREES TO REMAIN SHALL BE PROPERLY PROTECTED DURING CONSTRUCTION. PROTECTION TECHNIQUES SHALL BE
REVIEWED AND APPROVED BY THE LANDSCAPE ARCHITECT.
12.PRUNE TREES IN ACCORDANCE WITH THE SPECIFICATIONS SO THAT DISTURBED AREAS ARE RETURNED TO PRE-CONSTRUCTION
CONDITIONS OR BETTER.
13.CONTRACTOR SHALL PROVIDE FULL DEPTHS OF LOAM AS NOTED ON DETAILS AND AS SPECIFIED, FOR ALL PLANTING.
14.ALL LAWN AREAS DISTURBED BY CONSTRUCTION OPERATIONS INSIDE AND OUTSIDE THE LIMIT OF WORK SHALL BE LOAMED AND
SEEDED AS SPECIFIED.
15.ESTABLISHMENT PERIOD AND GUARANTEE SHALL BE 1 YEAR FROM ACCEPTANCE OF FINAL PLAN.
16.PLANTINGS LOCATED ON PROPERTY LINES OR NEIGHBORING PROPERTY SHALL BE DONE ONLY AFTER AUTHORIZATION BY
OWNER'S REPRESENTATIVE.
PLANT SCHEDULE
SEED MIX 1: URBAN CONSERVATION MIX
SEED MIX 2: VERMONT CONSERVATION MIX
TREE PROTECTION FENCE
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
Landscape Details
06/14/2024
Shown
22-512
JLA
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
040.1.1
LAWN SEEDING
LAST REVISED 12/29/2020TRUDELL CONSULTING ENGINEERS
NOTE: ALL DISTURBED AREAS SHALL BE LOAMED
AND SEEDED UNLESS NOTED OTHERWISE
6"
SEED AS SPECIFIED
PLANTING SOIL MIX,
(ROLLED THICKNESS)
FREE DRAINING,
SCARIFIED
SUBGRADE
1" = 1'
L-010.1.7
DECIDUOUS TREE PLANTING
TRUDELL CONSULTING ENGINEERS LAST REVISED 07/10/2023
EQEQ EQ
2"X2"X10' FIR STAKES; 2-3 PER TREE EQUALLY SPACED
AROUND ROOT BALL; ALL POSTS SHALL BE PLUMB AND
HAVE SAME HEIGHT ABOVE FINISH GRADE. INSTALL
STAKES ONLY AS REQUIRED BY SITE CONDITIONS.
GUY WIRE SHALL BE TREE TIE WEBBING MATERIAL.
TREE SHALL BE PLUM AFTER SETTLEMENT
TOP OF ROOTBALL SHALL BEAR SAME
RELATIONSHIP TO FINISHED GRADE AS
TO PREVIOUS EXISTING GRADE
ROOT FLARE SHALL BE EXPOSED; MULCH
SHOULD NOT BE WITHIN 4" OF TREE TRUNK
PLACE BALL ON SUBSOIL. REMOVE AND
DISCARD BURLAP EXCEPT UNDER BALL.
REMOVE ALL SYNTHETIC SOIL WRAPPING
MATERIALS (TREATED BURLAP, NYLON
TWINE, WIRE BASKETS, ETC.) AND DISCARD
EXCAVATE SUBSOIL AS REQUIRED TO
PLACE ROOTBALL TO PROPER ELEVATION.
PLACE ROOTBALL DIRECTLY ON SUBSOIL
EXCAVATE HOLE TO DIAMETER 3X WIDER THAN
ROOTBALL. BACKFILL HOLE WITH PLANTING
SOIL MIX AS SPECIFIED
BARK MULCH, AS SPECIFIED
FREE DRAINING UNDISTURBED OR
COMPACTED SUBGRADE
1/4" = 1'
4'
FOR ALL FALL PLANTING, WRAP TRUNK AT 2ND LOWERS
BRANCH. REMOVE SPECIFIED TREE WRAP THE
FOLLOWING SPRING
BARK MULCH SAUCER
L-029
1" = xx'
LAST REVISED 02/26/2020TRUDELL CONSULTING ENGINEERS
TREE PROTECTION
FOR TREES TO REMAIN WITHIN LIMIT OF LANDSCAPE
WORK AREA:
CONTRACTOR SHALL CONTACT ARBORIST PRIOR TO
DEMOLITION TO PERFORM RECOMMENDED TREATMENTS
(FERTILIZER, ROOT PRUNE, ETC.) ON SPECIMEN TREES TO
REMAIN BEFORE BEGINNING DEMOLITION.
PLAN VIEW
EXISTINGTREE
EXISTING
TREE
6' MIN.
SECTION VIEW
PRUNE PER ISA STANDARDS. REMOVE DEAD &
DAMAGED BRANCHES. TIE BRANCHES UP TO
AVOID DAMAGE FROM CONSTRUCTION
EQUIPMENT.
EXISTING TREE (S)
LI
M
I
T
O
F
D
R
I
P
L
I
N
E
(V
A
R
I
E
S
)
WOODEN OR METAL POSTS (TYPICAL)
INSTALL FENCING AT EDGE OF DRIPLINE OR AS FAR
FROM TRUNK AS POSSIBLE. MIN. DISTANCE IS 6' FROM
TRUNK. MAY BE PLASTIC SNOW FENCE OR CHAIN
LINK, MIN. 4' HIGH.
ZONE OF CONSTRUCTION IMPACT (CUT/FILL)
PRUNE DAMAGED OR EXPOSED
ROOTS DAMAGED WITH A SHARP
SAW.
LIMIT OF FENCING
(INDIVIDUAL TREE)
LIMIT OF FENCING (MULTIPLE TREES)
EXISTING GRADE
LIMIT OF CONSTRUCTION IMPACT (REFER TO PLANS)
LIMIT OF FENCE (INDIVIDUAL TREE)
LIMIT OF
CANOPY
(VARIES)
LIMIT OF FENCING
(MULTIPLE TREES)
WOODEN OR METAL POSTS (MAX. 8' SPACING)
2x4 DIM. LUMBER ATTACHED W/METAL
STRAPPING (OPT) AT 2 LOCATIONS
(MIN.). CLADDING SHALL BE 8' HIGH
WITH 6" SPACING OF BOARDS. WRAP
BARK W/BURLAP PRIOR TO
ARMORING, OR APPROVED
ALTERNATIVE METHOD
NO STORAGE OF EQUIPMENT OF
MATERIALS WITHIN DRIPLINE
LA2-01
LET
L-010.1.5
EVERGREEN TREE PLANTING
TRUDELL CONSULTING ENGINEERS LAST REVISED 12/29/2020
12"
LENGTH SET BY
HEIGHT OF
ROOTBALL
3
1
2" SHREDDED BARK MULCH, AS SPECIFIED
(HOLD MULCH OFF ROOT FLARE)
2"X2"X10' FIR STAKES , STAINED BLACK; 3 PER TREE
EQUALLY SPACED AROUND ROOT BALL; ALL POSTS
SHALL BE PLUMB AND HAVE SAME HEIGHT ABOVE FINISH
GRADE. GUY WIRE SHALL BE NEW PLIABLE ANNEALED
GALVANIZED SOFT STEEL WIRE OF NO. TEN(10) GAUGE
SIZE. ENCASE WIRE AROUND TRUNK IN TWO-PLY, BLACK,
REINFORCED RUBBER GARDEN HOSE
TREE SHALL BE PLANTED WITH TOP OF ROOTBALL
BEARING THE SAME RELATIONSHIP TO FINISHED GRADE
AS TO PREVIOUS EXISTING GRADE. TREE SHALL BE
PLUMB AFTER SETTLEMENT
4'
PLANTING SOIL MIX
ROLL BURLAP BACK FROM TOP 1/3 OF
ROOTBALL BEFORE BACKFILLING.
UNTIE ROPE FROM TRUNK
FREE DRAINING SCARIFIED SUBGRADE
1/2" = 1'
L-028
SHRUB PLANTING
LAST REVISED 02/29/2020TRUDELL CONSULTING ENGINEERS
12
"
M
I
N
.
PLACE SHRUBS PERPENDICULAR TO GRADE
CURB
2" BARK MULCH: PULL MULCH AWAY FROM BASE OF SHRUB,
HOLD TOP OF SETTLED MULCH 1" BELOW CURB
PLANTING SOIL MIX
THROUGHOUT ENTIRE PLANTING
AREA
FINISH GRADE
PLACE ROOTBALL
ON
COMPACTED
SUBGRADE
FREE DRAINING
SCARIFIED UNDISTURBED
SUBGRADE
1" = 1'
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
E N G I N E E R I N G S U R V E Y
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E
SSIONAL E N GI NEER
L ICEN S E D
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLANNIN G ENVIRON MENTAL
Lighting Plan
LI-01
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
06/18/2024
1" = 10'
22-512
AAD
AAD
0
Feet
Graphic Scale
10 20 30
OVERALL
PARKING AREA
SITE LIGHTING
LUMINAIRE SCHEDULE
SYMBOL LABEL QTY CATALOG NUMBER DESCRIPTION HEIGHT
A 15 FT
NOTES:
1.AREA LIGHT AS SHOWN FOR PERMITTING AND INSTALLATION PURPOSES.
2.DISCREPANCIES BETWEEN THIS SHEET AND OTHER CIVIL, ELECTRICAL, OR ARCHITECTURAL PLANS
SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO INSTALLATION.
3.QUANTITIES AND CATALOG NUMBER SHOWN IN TABLE SHOULD BE VERIFIED BY ELECTRIC
CONTRACTOR PRIOR TO ORDERING.
4
LEGEND
0.25 FOOTCANDLES (fc)
0.5 FOOTCANDLES (fc)
1.0 FOOTCANDLES (fc)
5.0 FOOTCANDLES (fc)
1.1 fc
1.1 fc
AVG. ILLUMINATION
(HORIZONTAL)
ARCHITECTURAL POST-TOP
MANUFACTURER
N/A
5.5:1
2.5 fc
2.5 fc
MAX. POINT
ILLUMINATION
UNIFORMITY RATIO
(AVG:MIN)
0.0 fc
0.2 fc
MIN. POINT
ILLUMINATION
HADCO VX60032-G3-C-3W-730-3
LAMP
38 WATT LED
A
A
A
A
STATISTICS
LI 010.1.3LAST REVISED 12/31/2020TRUDELL CONSULTING ENGINEERS
TYPICAL LUMINAIRE
GRASS AREAS
PAVED AREAS
A:MOUNT HEIGHT VARIES.
REFER SCHEDULE
B:BASE DEPTH 6 FT. MIN.
FOR UP TO 20 FT. MOUNT HEIGHT.
8 FT. MIN. FOR UP TO 30 FT.
C:PRECAST FOOTING DIAMETER
DETERMINED BY BASE PLATE
NOTE:
BOLT PATTERN, CONDUIT SIZE AND
GROUNDING TO BE DETERMINED BY
LIGHTING/ELECTRIC CONTRACTOR
B
℄
24
"
A
MO
U
N
T
H
E
I
G
H
T
V
A
R
I
E
S
A
MO
U
N
T
H
E
I
G
H
T
V
A
R
I
E
S
C
B
HADCO
ARCHITECTURAL POST TOP
PAINT EXPOSED FOOTING YELLOW
4"
CLASS B CONCRETE FOOTING
LEGEND
PROPOSEDEXISTING
STREAM
TRAIL
PROPERTY LINE
EASEMENTS
SETBACKS
WETLAND LIMIT
FENCE
TREE LINE
CLEANOUT (CO)
CATCH BASIN (CB)
GUARD RAIL
VALVE
CURB STOP (CS)
FIRE HYDRANT (HYD)
WATER SUPPLY WELL
END CAP
BLOWOFF
UTILITY POLE
LUMINAIRE
BOLLARD LIGHT
IRON PIPE
STEEL REBAR
IRON PIN (IP)
CALCULATED POINT
SOIL BORING
BENCHMARK
CONCRETE MONUMENT
STONEWALL
OVERHEAD UTILITY
SEWER FORCEMAIN
STORM DRAINAGE
CURTAIN DRAIN
UNDERDRAIN
ROOF DRAIN
FOOTING DRAIN
REMOVED/ABANDONED
PAVED DRIVE OR ROAD
GRAVEL DRIVE OR ROAD
TOPOGRAPHIC CONTOURS
OBSERVATION WELL
PERCOLATION TEST
SOIL TEST PIT
TO BE SETFOUND SET
RECORD DRAWING REQUIREMENTS:
1.A CLEAN SET OF UP TO DATE RECORD DRAWINGS IS TO BE AVAILABLE FOR REVIEW ON SITE AT ALL TIMES. FOR JOBS LASTING MORE THAN 4
WEEKS A REVIEW OF THE RECORD DRAWINGS WILL BE DONE BY THE ENGINEER EVERY 2 WEEKS AND COMMENTS OR DEFICIENCIES MAY BE
PROVIDED.
2.TIES TO ALL BENDS, VALVES, JOINTS, CONNECTIONS AND DESIGN FEATURES SHALL BE PROVIDED. TIES SHALL BE PULLED FROM EASILY
LOCATABLE PERMANENT ABOVE GROUND FEATURES THAT ARE VISIBLE YEAR AROUND SUCH AS BUILDING CORNERS, HYDRANTS, SEWER AND
STORM DRAIN COVERS THAT WILL BE CLEARED IN WINTER, UTILITY POLES, ETC. REFRAIN FROM PROVIDING TIES WITH ACUTE ANGLES. TIES
SHOULD BE PULLED AT ANGLES AS CLOSE TO 90 DEGREES AS POSSIBLE. TIES WITH ANGLES TOO ACUTE MAY BE REJECTED.
3.RECORD INFORMATION NEEDS TO BE PROVIDED ON THE APPROPRIATE DESIGN PLANS ON A WEEKLY BASIS. RECORD INFORMATION
REGARDING TCE DESIGN ITEMS PLACED ON INAPPROPRIATE DESIGN PLANS WILL NOT BE ACCEPTED.
4.TCE WILL ACCEPT ELECTRONIC RECORD COORDINATE INFORMATION, REFERENCED TO THE PROJECT DATUM. ELECTRONIC DATA SHALL BE
COMPUTER-AIDED DESIGN (CAD) FILES INCLUDING NATIVE FILE FORMATS (DWG).
5.IF ENGINEERING SERVICES FOR BI-WEEKLY REVIEW OF RECORD INFORMATION HAVE NOT BEEN OBTAINED FOR THE PROJECT ALL RECORD
INFORMATION FOR TCE DESIGN ITEMS SHALL BE PROVIDED TO TCE WITHIN 7 BUSINESS DAYS OF THE COMPLETION OF THE WORK.
6.PLANS SUBMITTED AT THE END OF THE PROJECT SHALL BE REVIEWED FOR COMPLETENESS. ALL REQUIREMENTS LISTED ABOVE APPLY.
7.IF DESIGN FEATURES WERE INSTALLED EXACTLY PER THE DESIGN PLANS TIES TO THE FEATURE ARE STILL REQUIRED TO BE PROVIDED BY THE
CONTRACTOR FOR THE OWNERS USE. ANY FEATURE NOT INDICATED AS DIFFERENT IN RED WILL BE CONSIDERED TO BE EXACTLY PER DESIGN.
8.RECORD INFORMATION SHALL INCLUDE BOTH VERTICAL AND HORIZONTAL LOCATIONS. THIS INCLUDES BUT IS NOT LIMITED TO FINISHED
FLOOR ELEVATIONS, RIMS AND INVERTS OF STRUCTURES AND PIPING, INVERTS AT CROSSINGS, ETC.
9.ANY UTILITIES ENCOUNTERED THAT ARE NOT SHOWN ON THE PLANS SHALL BE ADDED TO THE PLANS WITH APPROPRIATE TIES.
10.TIES SHALL INCLUDE ALL UTILITIES INSTALLED BY CONTRACTOR WHICH INCLUDE BUT ARE NOT LIMITED TO SEWER, WATER, STORM, ELECTRIC,
CABLE, TELEPHONE, GAS, ETC.
11.RECORD DRAWINGS SHALL BE SUPPLIED ON BOTH HARD COPY AND ELECTRONIC DATA. ELECTRONIC DATA SHALL BE COMPUTER-AIDED
DESIGN (CAD) FILES INCLUDING NATIVE FILE FORMATS (DWG).
12.THE CONTRACTOR SHALL SUBMIT ON A WEEKLY BASIS PROJECT PHOTOGRAPHS. THE INFORMATION WILL BE SUBMITTED TO THE ENGINEER IN
ELECTRONIC FORMAT WITH EACH PICTURE BEING LABELED BY DATE, LOCATION AND ACTIVITY. AT A MINIMUM THE CONTRACTOR WILL
SUBMIT PICTURES OF ALL THRUST BLOCKS, CONNECTIONS TO EXISTING FACILITIES AND STRUCTURES BEFORE AND AFTER BACKFILL. PROVIDE
AUXILIARY LIGHTING AS REQUIRED TO PRODUCE CLEAR, WELL-LIT PHOTOGRAPHS WITHOUT OBSCURING SHADOWS. THE CONTRACTOR SHALL
MAINTAIN ONE CHECK SET OF PHOTOGRAPHS AT THE SITE FOR REFERENCE. UPON REQUEST THE CONTRACTOR SHALL PROVIDE PICTURES OF
VARIOUS AREAS DEEMED NECESSARY BY THE ENGINEER OR OWNER.
13.CERTIFICATIONS BY THE ENGINEER AND SUCCESSFUL TEST RESULTS DO NOT RELIEVE THE CONTRACTOR OF FULL COMPLIANCE WITH THE
DESIGN PLANS, SPECIFICATIONS AND PERMITS SHOULD A DEFICIENCY BE DISCOVERED AFTER SAID CERTIFICATION OR TESTING.
SPECIAL NOTE:
FOR CLARITY, ALL ORIGINAL COLOR SHEETS
MUST BE REPRODUCED IN COLOR
CONSTRUCTION PHASE:
LISTED BELOW IS A BRIEF SUMMARY OF CONSTRUCTION PHASE REQUIREMENTS. THIS LIST IS NOT INTENDED
TO BE ALL-INCLUSIVE. CONSTRUCTION SPECIFICATIONS, PERMIT REQUIREMENTS AND SUBSEQUENT
CONTRACTUAL AGREEMENTS FROM PARTIES INVOLVED SHALL PREVAIL.
PRE-CONSTRUCTION
·OWNER TO ESTABLISH SCOPE OF SERVICES WITH PROJECT ENGINEER(S)
·OWNER TO IDENTIFY WORK SCOPE AND SCHEDULE
·UPON OWNER REQUEST, ENGINEER WILL ASSIST WITH CONTRACTOR BID AND SELECTION PROCESS
·ENGINEER TO FINALIZE PLANS FOR CONSTRUCTION READINESS INCLUDING SPECIFICATIONS
·MEETING BETWEEN OWNER, ENGINEER(S), CONTRACTOR(S), ARCHITECT(S), REGULATORY AUTHORITIES
AND OTHER PERTINENT PARTIES TO REVIEW AND DISCUSS THE WORK
PRE-CONSTRUCTION MEETING
·CONTRACTOR TO IDENTIFY SUPERINTENDENT WITH AUTHORITY TO MAKE DECISIONS
·CONTRACTOR TO IDENTIFY SUBCONTRACTORS
·CONTRACTOR TO ESTABLISH SCHEDULE
·CONTRACTOR TO DESIGNATE RESPONSIBLE PERSONNEL
·CONTRACTOR TO CONFIRM PROCEDURE FOR RFI'S, CHANGE ORDERS, EXTRAS AND PAY REQUESTS
·CONTRACTOR TO SUBMIT SHOP DRAWINGS
·CONTRACTOR TO OUTLINE SAFETY, SECURITY, AND WORKING HOURS
·CONTRACTOR OR OWNER TO IDENTIFY TESTING COMPANY
CONSTRUCTION PHASE
·INITIAL CONTROL SUPPLIED BY OWNER AND CONTRACTOR RESPONSIBLE FOR LAYOUT
·PROJECT ENGINEER TO ESTABLISH BENCHMARK AND IN SOME CASES INITIAL SITE LAYOUT
·DISCUSS RESTRICTIONS SUCH AS, BUT NOT LIMITED TO, WETLANDS OR TREE LINE
·REVIEW EXISTING AND REQUIRED PERMITS
·DIGSAFE AND PERMIT NUMBER
·ADDITIONAL UNDERGROUND LAYOUT BY PRIVATE COMPANY
·DISCUSS EROSION CONTROL
·OWNER TO PROVIDE PROJECT ENGINEER TO OBSERVE CONSTRUCTION PERIODICALLY, DURING
CRITICAL PHASES AND TESTING
·WEEKLY JOB MEETINGS DURING CONSTRUCTION UNLESS INDICATED OTHERWISE.
·OWNER TO PROVIDE PROJECT ENGINEER TO REVIEW AND DISCUSS PLANS, ANSWER QUESTIONS,
RESPOND TO CHANGES, APPROVE SUBMITTALS, AND OTHER BUSINESS COMMON TO CONSTRUCTION
SERVICES.
·ENGINEER TO OBSERVE TESTING AND COLLECT RESULTS
·OWNER AND CONTRACTOR TO COMPLY WITH PERMITS
·CONTRACTOR CERTIFICATION (PROVIDED BY CONTRACTOR)
·PICTURE AND RECORD DRAWINGS (PROVIDED BY CONTRACTOR)
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PAVED DRIVE OR ROAD
WITH CURB
SEWER MAINS
AND SERVICES
WATER MAINS
AND SERVICES
LIQUID PROPANE
OR NATURAL GAS
UNDERGROUND UTILITY
MARBLE OR STONE
MONUMENT
TCE CONTROL POINT
MAG NAIL
TCE CONTROL POINT
STEEL REBAR
MTC OR TRANSFORMER
OUTLET OR
END SECTION
ØØØØ
S S
èèèè
124
FM
W
CD
UD
RD
FD
G
OH
UG
SB SB
124
W
CD
UD
RD
FD
G
OH
UG
SB SB
ØØØØØØ
S S S S S
FM FM FM
W W W W
D D D D
CD CD CD
UD UD UD
RD RD RD
FD FD FD
G G G G
OH OH OH
UG UG UG
FM
D
Legend & Notes
C1-00
06/18/2024
N/A
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
LEGEND NOTE:
SOME INFORMATION MAY BE PROVIDED BY OTHERS AND COULD BE SHOWN WITH A DIFFERENT SYMBOL NOT SHOWN ON THIS
LEGEND. HOWEVER, THEY ARE LABELED ON RESPECTIVE PLANS. IN SOME CASES A CHANGE IN SCALE OR PRINTER CAN ALTER
INFORMATION TO NOT SHOW AN EXACT MATCH ON THIS LEGEND. IF ANY QUESTIONS EXIST CONTACT THE ENGINEER TO CLARIFY.
ADDITIONAL LEGEND INFORMATION IS SUPPLIED SEPARATELY ON EROSION CONTROL PLANS AND SOME SURVEY PLATS.
SEWER, DRAINAGE OR TELEPHONE MANHOLE
(SMH/DMH/TMH)
TELEPHONE OR TELEVISION PEDESTAL
(TEL-PED/TV-PED)
ADJOINING PROPERTY LINE
WELL CONE /
WASTEWATER CONE OF INFLUENCE
SIGN
P-
XXMIN./IN.
SURVEY
CANOPY LIGHT
FLOOD OR WALL LIGHT
W
YARD DRAIN (YD)
GAS OR ELECTRICAL METER
18"
TP-
WETLAND BUFFER
CONSTRUCTION NOTES FOR CONTRACTOR & CLIENT/OWNER:
1.CONTRACT DOCUMENTS: THESE PLANS WERE PREPARED BY TRUDELL CONSULTING ENGINEERS (TCE) AND ARE INTENDED TO BE USED IN CONJUNCTION WITH THE STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT, #C-700 PREPARED BY THE ENGINEERS JOINT CONTRACT
DOCUMENTS COMMITTEE (EJCDC), LATEST EDITION. COPIES ARE AVAILABLE AT WWW.NSPE.ORG/EJCDC.
2.UNDERGROUND IMPROVEMENTS: THE LOCATION OF EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS SHOWN ARE ASSUMED BASED ON RESEARCH, UTILITY PLANS PROVIDED BY OTHERS, AND/OR SURFACE EVIDENCE AVAILABLE AND WERE OBTAINED IN A MANNER CONSISTENT WITH THE
ORDINARY STANDARD OF PROFESSIONAL CARE AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE DESIGN ENGINEER.
3.DIFFERING SUBSURFACE OR PHYSICAL CONDITIONS: IF CONTRACTOR BELIEVES THAT ANY SUBSURFACE OR PHYSICAL CONDITION AT OR CONTIGUOUS TO THE SITE THAT IS UNCOVERED OR REVEALED EITHER: (1) IS OF SUCH A NATURE AS TO ESTABLISH THAT ANY “TECHNICAL DATA” ON WHICH
CONTRACTOR RELIED IS MATERIALLY INACCURATE; OR (2) IS OF SUCH A NATURE AS TO REQUIRE A CHANGE IN THE PLANS/CONTRACT DOCUMENTS; OR (3) DIFFERS MATERIALLY FROM THAT SHOWN OR INDICATED IN THE PLANS/CONTRACT DOCUMENTS; OR (4) IS OF AN UNUSUAL NATURE, AND
DIFFERS MATERIALLY FROM CONDITIONS ORDINARILY ENCOUNTERED AND GENERALLY RECOGNIZED AS INHERENT IN WORK OF THE CHARACTER PROVIDED FOR IN THE PLANS/CONTRACT DOCUMENTS; THEN CONTRACTOR SHALL, PROMPTLY AFTER BECOMING AWARE THEREOF AND BEFORE
FURTHER DISTURBING THE SUBSURFACE OR PHYSICAL CONDITIONS OR PERFORMING ANY WORK IN CONNECTION THEREWITH (EXCEPT IN AN EMERGENCY), NOTIFY OWNER AND ENGINEER ABOUT SUCH CONDITION. CONTRACTOR SHALL NOT FURTHER DISTURB SUCH CONDITION OR PERFORM ANY
WORK IN CONNECTION THEREWITH (EXCEPT AS AFORESAID) UNTIL RECEIPT OF WRITTEN ORDER TO DO SO. ALL PARTIES INVOLVED (OWNER, ENGINEER, ARCHITECT AND MUNICIPALITY IF APPLICABLE) SHALL AGREE UPON HOW TO PROCEED AND ANY RELATED COST IMPLICATIONS.
4.UTILITIES: PRIVATE AND PUBLIC UTILITIES SUCH AS ELECTRIC, TELEPHONE, GAS, CABLE, FIBER OPTIC ETC. ARE THE RESPONSIBILITY OF THE RESPECTIVE UTILITY COMPANY. ANY INFORMATION SHOWN BY TCE SHOULD BE CONSIDERED PRELIMINARY (USUALLY TO ASSIST WITH PERMITTING.) FINAL DESIGN,
CONSTRUCTION AND MAINTENANCE ARE THE RESPONSIBILITY OF RESPECTIVE UTILITY COMPANIES. COMPLIANCE WITH EASEMENTS AND REGULATIONS (STATE AND LOCAL) ARE THE RESPONSIBILITY OF RESPECTIVE UTILITY COMPANY.
5.DIGSAFE: IN ACCORDANCE WITH VERMONT STATE LAW (VSA TITLE 30 CHAPTER 86 AND PSB RULE 3,800) THE CONTRACTOR SHALL BE RESPONSIBLE TO CONTACT DIGSAFE SYSTEMS, INC. “DIGSAFE.” AT LEAST 48 HOURS , EXCLUDING SATURDAYS, SUNDAYS, AND LEGAL HOLIDAYS, BUT NOT MORE
THAN 30 DAYS BEFORE COMMENCING EXCAVATION ACTIVITIES, EXCEPT IN AN EMERGENCY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PRE-MARKING THE SITE AND MAINTAINING DESIGNATED MARKINGS. FOR MORE INFORMATION ON DIGSAFE REQUIREMENTS SEE WWW.DIGSAFE.COM.
6.JOBSITE SAFETY: NEITHER THE PROFESSIONAL ACTIVITIES OF TRUDELL CONSULTING ENGINEERS (TCE), NOR THE PRESENCE OF TCE OR ITS EMPLOYEES AND SUB CONSULTANTS AT A CONSTRUCTION SITE, SHALL RELIEVE THE GENERAL CONTRACTOR AND ANY OTHER ENTITY OF THEIR OBLIGATIONS,
DUTIES AND RESPONSIBILITIES INCLUDING, BUT NOT LIMITED TO, CONSTRUCTION MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING, SUPERINTENDING OR COORDINATING ALL PORTIONS OF THE WORK OF CONSTRUCTION IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS AND ANY HEALTH OR SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES. TCE AND ITS PERSONNEL HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER ANY CONSTRUCTION CONTRACTOR OR OTHER ENTITY OR THEIR EMPLOYEES IN CONNECTION WITH
THEIR WORK OR ANY HEALTH OR SAFETY PRECAUTIONS. THE CLIENT AGREES THAT THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR JOBSITE SAFETY, AND WARRANTS THAT THIS INTENT SHALL BE MADE EVIDENT IN THE CLIENT'S AGREEMENT WITH THE GENERAL CONTRACTOR. THE CLIENT ALSO
AGREES THAT THE CLIENT, TCE AND TCE'S CONSULTANTS SHALL BE INDEMNIFIED AND SHALL BE MADE ADDITIONALLY INSURED UNDER THE GENERAL CONTRACTOR'S GENERAL LIABILITY INSURANCE POLICY.
7.CODES AND STANDARDS COMPLIANCE: TCE SHALL EXERCISE USUAL AND CUSTOMARY PROFESSIONAL CARE IN ITS EFFORTS TO COMPLY WITH CODES, STANDARDS, REGULATIONS AND ORDINANCES IN EFFECT. THE OWNER ACKNOWLEDGES THAT SUCH REQUIREMENTS MAY BE SUBJECT TO
VARIOUS AND CONTRADICTORY INTERPRETATIONS. TCE, THEREFORE, WILL USE ITS REASONABLE PROFESSIONAL EFFORTS AND JUDGMENT TO INTERPRET APPLICABLE REQUIREMENTS AS THEY APPLY TO THE PROJECT. TCE, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT THE
PROJECT WILL COMPLY WITH ALL INTERPRETATIONS OF SUCH REQUIREMENTS.
8.CONSTRUCTION OBSERVATION: TCE MAY VISIT THE PROJECT AT APPROPRIATE INTERVALS DURING CONSTRUCTION TO BECOME GENERALLY FAMILIAR WITH THE PROGRESS AND QUALITY OF THE CONTRACTOR'S WORK AND TO DETERMINE IF THE WORK IS PROCEEDING IN GENERAL ACCORDANCE
WITH THE CONTRACT DOCUMENTS. THE OWNER HAS NOT RETAINED TCE TO MAKE DETAILED INSPECTIONS OR TO PROVIDE EXHAUSTIVE OR CONTINUOUS PROJECT REVIEW AND OBSERVATION SERVICES. TCE DOES NOT GUARANTEE THE PERFORMANCE OF, AND SHALL NOT HAVE RESPONSIBILITY
FOR, THE ACTS OR OMISSIONS OF ANY CONTRACTOR, SUB-CONTRACTOR, SUPPLIER OR ANY OTHER ENTITY FURNISHING MATERIALS OR PERFORMING ANY WORK ON THE PROJECT. TCE SHALL NOT SUPERVISE, DIRECT OR HAVE CONTROL OVER THE CONTRACTOR'S WORK NOR HAVE ANY
RESPONSIBILITY FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OF THE CONTRACTOR. IF THE OWNER DESIRES MORE EXTENSIVE PROJECT OBSERVATION OR FULL-TIME PROJECT REPRESENTATION, THE OWNER SHALL REQUEST SUCH SERVICES BE PROVIDED
BY TCE AS ADDITIONAL SERVICES.
9.CONTAMINATED SOILS NOTES: CONTRACTOR SHALL ABIDE BY LOCAL, STATE, AND FEDERAL REGULATIONS AND BEST PRACTICES REGARDING CONTAMINATED SOILS FROM PRIOR SITE USE. REFER TO APPROVED CORRECTIVE ACTION PLAN (CAP) AND MOST RECENT ENVIRONMENTAL/SOILS
REMEDIATION PLANS PREPARED BY KAS CONSULTING. SHORT AND LONG TERM MONITORING AND CAP SHALL BE APPROVED BY THE VERMONT DEPARTMENT OF ENVIRONMENTAL CONSERVATION. CORRECTIVE ACTION PLAN (CAP) AND SHORT AND LONG TERM SOILS MONITORING TO BE
APPROVED BY THE VERMONT DEPARTMENT OF ENVIRONMENTAL CONSERVATION. ALL EXCAVATION ON SITE SHALL ADHERE TO DEWATERING PRACTICES INCLUDING CHECK DAMS AND SILT BAG IMPLEMENTATION IN ACCORDANCE WITH THE EXCAVATION DEWATERING DETAIL ON C8-04.
10.THE PROJECT SHALL BE ADA COMPLIANT. THE CONTRACTOR SHALL SUBMIT SHOP DRAWING ON ADA COMPLIANT AREA PRIOR TO CONSTRUCTION.
11.THE CONTRACTOR SHALL REPAIR/RESTORE ALL DISTURBED AREAS (ON OR OFF THE SITE) AS A DIRECT OR INDIRECT RESULT OF THE CONSTRUCTION. ALL GRASSED AREAS SHALL BE MAINTAINED UNTIL FULL VEGETATION IS ESTABLISHED. MAINTAIN ALL TREES OUTSIDE OF CONSTRUCTION LIMITS.
12.IN ADDITION TO THE REQUIREMENTS SET IN THESE PLANS AND SPECIFICATIONS, THE CONTRACTOR SHALL COMPLETE THE WORK IN ACCORDANCE WITH ALL PERMIT CONDITIONS, LOCAL PUBLIC WORKS STANDARDS AND ALL CONSTRUCTION SAFETY REGULATIONS.
13.ANY DEWATERING NECESSARY FOR THE COMPLETION OF THE SITEWORK SHALL BE CONSIDERED AS PART OF THE CONTRACT AND SHALL BE THE CONTRACTOR'S RESPONSIBILITY.
14.IF THERE ARE ANY CONFLICTS OR INCONSISTENCIES WITH THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR VERIFICATION BEFORE WORK CONTINUES ON THE ITEM(S) IN QUESTION.
15.SEWER LATERAL CONNECTIONS ARE SOMETIMES NOT SHOWN FOR CLARITY. CONTRACTOR TO CONSULT WITH ENGINEER AND SUPPLY BENDS, CLEANOUTS, ETC. AS NECESSARY TO FACILITATE PROPER CONNECTION BETWEEN FOUNDATION WALL AND SEWER MAIN LINE.
16.CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH ALL RELEVANT PARTIES (INCLUDING, BUT NOT LIMITED TO OWNER, ARCHITECT AND UTILITY COMPANIES) TO DETERMINE FINAL LAYOUT AND DESIGN.
17.DESIGN AND CONSTRUCTION OF PEDESTRIAN WALKS, RAMPS AND DECKS BETWEEN BUILDINGS AND PARKING LOTS IS PROVIDED BY THE ARCHITECT AND INCORPORATED INTO THE BUILDING DESIGN, UNLESS INDICATED OTHERWISE.
18.ALL WATER LINE TAPS SHALL BE LIVE TAPS; EXISTING WATER LINE MUST REMAIN IN SERVICE DURING CONNECTION, UNLESS INDICATED OTHERWISE.
19.ROOF DOWNSPOUT CAN CONNECT TO ROOF DRAIN MANIFOLD (RD) AS DETERMINED BY ARCHITECT AND OWNER. THIS CONNECTION PIPE IS INCLUDED AS PART OF THE DESIGN PLAN BUT NOT SHOWN TO ALLOW FLEXIBILITY IN LOCATION AS NEEDED.
20.THRUST BLOCKS FOR PRESSURE LINES ARE NOT SHOWN FOR CLARITY PURPOSES. PROVIDE THRUST BLOCKS AT ALL BENDS, TEE AND REDUCES. PROJECT ENGINEER TO OBSERVE ALL THRUST BLOCKS PRIOR TO BACKFILL.
21.WATER MAIN OPERATED AT HIGH PRESSURE. ALL BUILDINGS SHALL CONFIRM STATIC INTAKE PRESSURE AND PROVIDE PRESSURE-REDUCING VALVES AS DEEMED APPROPRIATE BY THE MECHANICAL ENGINEER (OR ARCHITECT.)
22.CONTRACTOR TO SUPPLY DAYLIGHT PIPING FOR FOOTING DRAINS WITHIN CONSTRUCTION LIMITS. THE EXACT LOCATION MAY NOT BE CRITICAL. COORDINATE WITH OWNER AND PROJECT ENGINEER.
23.FOOTING DRAINS AROUND BUILDING MAY BE SHOWN BY OTHERS (BECAUSE IT IS WITHIN THE 5' ZONE AROUND BUILDING). FOOTING DRAINS AND PIPE TO DAYLIGHT SHALL BE INCLUDED EVEN IF NOT SHOWN. DAYLIGHT PIPE LOCATION TO SWALE MAY NOT BE CRITICAL SO LONG AS IT DOES NOT
CREATE ANY CONFLICT WITH OTHER UTILITIES, OR IMPACT ENVIRONMENTALLY SENSITIVE AREAS SUCH AS WETLANDS.
24.SEWER CONNECTIONS TO EXISTING MANHOLES SHALL INCLUDE WATERTIGHT CONNECTIONS, REFORMING INVERT TO PROVIDE SMOOTH FLOW STREAM AND TESTING TO ENSURE STRUCTURE IS WATERTIGHT. IF AN EXISTING MANHOLE IS FOUND NOT TO BE WATERTIGHT IT SHALL BE EXPOSED AND
REPAIRED ON THE OUTSIDE. PRIOR TO CONNECTING TO EXISTING MANHOLES, SUBMIT SHOP DRAWINGS ON CORE LOCATION, ANY REQUIRED PIPING (FOR DROP MANHOLES) AND CHANGES TO INVERT FORM.
25.FINAL RIMS OF SEWER MANHOLES AND WATER VALVES SHALL BE CONFIRMED AND COORDINATED WITH FINAL SITE GRADING. MINOR ADJUSTMENTS FROM DESIGN GRADES MAY BE REQUIRED BY OWNER OR ENGINEER AND SHALL BE INCLUDED.
26.ROCK REMOVAL WORK FOR BOULDERS UNDER 2.5 CUBIC YARDS IS INCLUDED AS PART OF EXCAVATION. ANY ROCK REMOVAL FOR 2.5 CUBIC YARDS OR GREATER SHALL BE TREATED AS LEDGE REMOVAL. THIS SHOULD BE REVIEWED AND AGREED UPON BY OWNER PRIOR TO CONDUCTING ROCK
REMOVAL.
27.THE GENERAL CONTRACTOR IS REQUIRED TO CONFORM TO THE STRICTEST INTERPRETATION OF THE CONTRACT DRAWING, SPECIFICATION, PERMITS AND CONSTRUCTION CONTRACT. ALL EARTH MATERIAL RECEIVED OR DISPOSED FROM OUTSIDE SOURCES SHALL COMPLY WITH APPLICABLE
PERMITS AND REGULATIONS. SHOP DRAWING SUBMITTALS SHALL INCLUDE CONTRACTOR'S CERTIFICATION STATEMENT OF COMPLIANCE AND COPIES OF RELEVANT PERMITS FOR OUTSIDE SOURCES.
28.CONTRACTOR SHALL PAY FOR ALL REQUIRED TESTING. THIS SHALL INCLUDE BUT IS NOT LIMITED TO: SOIL TESTING, COMPACTION TESTING, SIEVE ANALYSIS, CONCRETE TESTING, ASPHALT PENETRATION TESTING, BACTERIOLOGICAL TESTING FOR WATER AND OTHER TESTING AS PART OF STANDARD
PRACTICE FOR A CONSTRUCTION PROJECT OF THIS NATURE, UNLESS INDICATED OTHERWISE AND APPROVED BY THE OWNER.
CONSTRUCTION READY PLAN:
ONCE THE PLANS ARE FULLY PERMITTED, CONTACT THE ENGINEER TO PREPARE CONSTRUCTION READY
PLANS. UPDATES INCLUDE BUT ARE NOT LIMITED TO MORE SPECIFIC SITE DETAIL, COORDINATION WITH
THE OWNER, COORDINATION WITH OTHER DISCIPLINES, COORDINATE WITH UTILITY COMPANIES,
FINISHED SPOT GRADES AN OTHER PERTINENT INFORMATION TO ASSIST WITH THE CONSTRUCTION PHASE.
D
L328.93'
R1040.00'
U
P
UP
UP
D
D
EXISTING SIGHT
DISTANCE EASEMENT
EXISTING
STORMWATER
EASEMENT
CLASS II
WETLAND
J
CLASS III
WETLAND
C
CLASS III
WETLAND E-K
CLASS III
WETLAND
D
CLASS II
WETLAND
G
CLASS III
WETLAND
I
CLASS III
WETLAND
F
CLASS III
WETLAND
M
CLASS II
WETLAND
A
CLASS II
WETLAND
A
CLASS II
WETLAND
A
CLASS II
WETLAND
J
CLASS III
WETLAND
L
CLASS II
WETLAND
A
CLASS II
WETLAND
A
CLASS II
WETLAND
A
EXISTING COMMUNITY GARDENS
EXISTING DRILLED WELL
EXISTING ELECTRICAL PANEL
EXISTING BURIED
ELECTRIC &
COMMUNICATION
CABLES
1
0
0
'
W
E
T
L
A
N
D
B
U
F
F
E
R
10
0
'
WE
T
L
A
N
D
BU
F
F
E
R
100'
WETL
A
N
D
BUF
F
E
R
100'
WETLAND
BUFFER
100'
WETL
A
N
D
BUFF
E
R
100'
WETLAN
D
BUFFER
100'
CITY
WETLAND
BUFFER
UPLAND
Au
UPLAND
Ai
EXISTING
UTILITY
EASEMENT
SP
E
A
R
S
T
R
E
E
T
UPSWEPT LANE
VA
L
E
D
R
FO
U
R
S
I
S
T
E
R
S
RO
A
D
P
A
R
K
S
I
D
E
D
R
N 79°34'04
"
W
361.57'
N 1
2
°
5
0
'
3
8
"
E
17
0
.
0
0
'
N 1
2
°
5
0
'
3
8
"
E
27
8
.
1
0
'
S 79°01'06
"
E
395.03'
S 82°18'39" W
1010.93'
S
0
4
°
3
4
'
2
5
"
E
11
4
.
6
3
'
S 82°14'13" W
19.56'
S 82°26'52" W
2331.88'
S
0
7
°
4
1
'
2
1
"
E
99
1
.
4
7
'
N 1
2
°
4
7
'
1
2
"
E
10
3
1
.
9
4
'
S 83°31'16" W
212.80'
LOT 32
PIN
N
A
C
L
E
D
R
I
V
E
NOWLAND FARM R
D
TO SPEA
R
S
T
R
E
E
T
EXISTING
HOME,
TYP.
EXISTING
PARKING AREA
(TO BE REMOVED)
N/F
LIANG WAN TING
N/F
WILLIAM & JUDITH MCMEEKIN
N/F
KELLEY GARDNER TRUST
N/F
MURALIDHAR MULPURI
N/F
RYAN & KIMBERLY PINKHAM
N/F
DALE & MARIE BAUMAN
N/F
THE SOUTH POINT HOMEOWNERS ASSOC. INC.N/F
THE SOUTH POINT HOMEOWNERS ASSOC. INC.
50' CITY CLASS III
BUFFER
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
E N G I N E E R I N G S U R V E Y
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E
SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLANNIN G ENVIRON MENTAL
0
Feet
Graphic Scale
100 200 300
Overall Existing
Conditions Plan
C1-01
06/18/2024
1" = 100'
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
1 06/14/24 AADZoning & Vegetation
0
Feet
Graphic Scale
100 200 300
15°±
VT
G
r
i
d
Ma
g
n
e
t
i
c
NOTES:
1.THE PROJECT PROPERTY LINES SHOWN ON THIS PLAN ARE BASED ON A
COMBINATION OF CITY OF SOUTH BURLINGTON TAX MAPS AND A PLAN
ENTITLED "NOWLAND PROPERTY II, SUBDIVISION PLAN", DATED MARCH
1991, BY FITZPATRICK- LLEWELLYN, INC., RECORDED IN MAP VOL. 286, PG.
23 OF THE CITY OF SOUTH BURLINGTON LAND RECORDS, AND LOT 32
SOUTH POINTE SUBDIVISION PLAT BY LAMOUREUX & DICKINSON DATED
6/10/2014, RECORDED IN MAP VOL. 580, PG. 4 OF THE CITY OF SOUTH
BURLINGTON LAND RECORDS.
2.WETLANDS SHOWN WERE INITIALLY DELINEATED BY GILMAN & BRIGGS
ENVIRONMENTAL ON OCTOBER 9-10, 2018. MAPPING PROVIDED BY
GILMAN & BRIGGS. WETLANDS A (WEST & NORTH SIDES), C, D. E-K AND F
WERE RE-DELINEATED BY GILMAN & BRIGGS ON APRIL 29, 2020. THE
APRIL 2020 DELINEATIONS WERE FIELD-SURVEYED BY LAMOUREUX &
DICKINSON.
3.EXISTING GARDEN PLOT, DRILLED WELL & ELECTRICAL SERVICE
OPERATED BY COMMON ROOTS UNDER A LEASE AGREEMENT WITH THE
CITY OF SOUTH BURLINGTON.
NE
I
G
H
B
O
R
H
O
O
D
R
E
S
I
D
E
N
T
I
A
L
NA
T
U
R
A
L
R
E
S
O
U
R
C
E
P
R
O
T
E
C
T
I
O
N
NA
T
U
R
A
L
R
E
S
O
U
R
C
E
P
R
O
T
E
C
T
I
O
N
NE
I
G
H
B
O
R
H
O
O
D
R
E
S
I
D
E
N
T
I
A
L
U
P
UP
UP
D
D
EXISTING COMMUNITY GARDENS
EXISTING DRILLED WELL
EXISTING ELECTRICAL PANEL
EXISTING BURIED
ELECTRIC &
COMMUNICATION
CABLES
EXISTING
HOME,
TYP.
N/F
LIANG WAN TING
N/F
WILLIAM & JUDITH MCMEEKIN
N/F
KELLEY GARDNER TRUST
N/F
N/F
DALE & MARIE BAUMAN
N/F
THE SOUTH POINT HOMEOWNERS ASSOC. INC.N/F
THE SOUTH POINT HOMEOWNERS ASSOC. INC.
N
O
W
L
A
N
D
F
A
R
M
R
D
SP
E
A
R
S
T
R
E
E
T
UPSWEPT LANE
VA
L
E
D
R
FO
U
R
S
I
S
T
E
R
S
RO
A
D
CLASS II
WETLAND
CLIMATE CHANGE
STUDY AREA
PIN
N
A
C
L
E
D
R
I
V
E
NOWLAND FARM RD
SH
E
E
T
C
6
-
0
1
SH
E
E
T
C
6
-
0
2
SH
E
E
T
C
6
-
0
3
PROPOSED PARKING LOT
PROPOSED 10' WIDE SHARED USE PATH
PROPOSED 10' WIDE MOWED GRASS PATH
TO SPEA
R
S
T
R
E
E
T
P
A
R
K
S
I
D
E
D
R
EXISTING MOWED PATH
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
E N G I N E E R I N G S U R V E Y
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E
SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLANNIN G ENVIRON MENTAL
0
Feet
Graphic Scale
100 200 300
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
Overall Site Plan
C2-01
06/18/2024
1" = 100'
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
1 06/14/24 AADZoning & Vegetation
LOCATION PLAN
NTS
SP
E
A
R
S
T
R
E
E
T
NOWLAND FARM
R
D
DO
R
S
E
T
S
T
R
E
E
T
VT
G
R
I
D
ALLEN RD
PROJECT
SITE
PROJECT INFORMATION:
1.OWNER OF RECORD: CITY OF SOUTH BURLINGTON
575 DORSET ST.
SOUTH BURLINGTON, VERMONT 05403
2.TAX PARCEL ID: 1640-01600
3.PHYSICAL ADDRESS NOWLAND FARM ROAD
OF PROPERTY:SOUTH BURLINGTON, VT
4.ZONING DISTRICTS:SEQ - NEIGHBORHOOD RES
SEQ - NATURAL RESOURCE PROTECTION
5.PARCEL SIZE: 60.7± ACRES; 2,644,092 SF
6.IMPERVIOUS SURFACES:
6.1.PARCEL # 1640-01600 (HUBBARD):
EXISTING IMPERVIOUS (FOR REMOVAL) = 0.1 AC
PROPOSED IMPERVIOUS = 0.49 AC
6.2.PARKSIDE DR ROW:
PROPOSED IMPERVIOUS = 0.06 AC
6.3.WITHIN NOWLAND FARM RD:
PROPOSED INCREASED IMPERVIOUS = 0.02 AC
TOTAL PROJECT INCREASE IN IMPERVIOUS = 0.57 ACRES
STORMWATER NOTE
PER CORRESPONDENCE WITH THE VERMONT AGENCY OF NATURAL RESOURCES
DEPARTMENT OF ENVIRONMENTAL CONSERVATION DATED APRIL 2023, THIS PROJECT IS
BELOW THE THRESHOLD REQUIRING A STORMWATER OPERATION PERMIT THROUGH
EXEMPTION 1.5.(F)(4) OF THE GENERAL PERMIT 3-9050.
NE
I
G
H
B
O
R
H
O
O
D
R
E
S
I
D
E
N
T
I
A
L
NA
T
U
R
A
L
R
E
S
O
U
R
C
E
P
R
O
T
E
C
T
I
O
N
NA
T
U
R
A
L
R
E
S
O
U
R
C
E
P
R
O
T
E
C
T
I
O
N
NE
I
G
H
B
O
R
H
O
O
D
R
E
S
I
D
E
N
T
I
A
L
G
G
G
W
W
W
W
W
W
W
W
W
W
392
392
392
392
391
391
391
391
391
390
390
390
390
3
9
0
390
389
389
389
389
38
8
388
388
388
387
387
387
386
386
38
5
CLASS II
WETLAND
A
390
39
0
390
391
39
1
39
1
3
9
1
39
1
39
1
390
39
0
3
9
0
390
3
9
0
3
9
0
3
9
0
3
8
9
3
8
9
3
8
8
3
8
8
3
8
7
387
38
7
386
EXI
S
T
I
N
G
M
O
W
E
D
G
R
A
S
S
P
A
T
H
PINNACL
E
D
R
I
V
E
PROPOSED PARKING LOT
NEW CROSSWALK
NEW
1
0
'
W
I
D
E
P
A
V
E
D
S
H
A
R
E
D
U
S
E
P
A
T
H
BIKE RACK
NEW PAVEMENT MARKINGS
NEW 10' WIDE MOWED GRASS PATH
PROPOSED LANDSCAPE WALL
SEE DETAIL
NEW CURB RAMP AND DETECTABLE
WARNING SURFACE, GRADED
EARTH STYLE
SEE DETAIL
6' BENCH
TO
S
P
E
A
R
S
T
R
E
E
T
INFORMATION KIOSK
POLE LIGHT, TYP
SIGN:
PEDESTRIAN CROSSING
W/ RECTANGULAR RAPID
FLASHING BEACON (RRFB)
392
392
392
392
392
392
391
3
9
1
391
391
NEW CURB RAMP, TYPE 2
SEE DETAIL
HANDICAP SIGN
"VAN ACCESSIBLE",
TYP.
HANDICAP SIGN,
TYP.
SIGN:
PEDESTRIAN CROSSING
W/ RECTANGULAR RAPID
FLASHING BEACON (RRFB)
EXISTING PAVEMENT TO BE REMOVED;
REGRADE, TOPSOIL, SEED, AND MULCH
TIE INTO EXISTING CURB
TIE INTO EXISTING CURB
EXISTING ASPHALT PATH
PROPOSED CONCRETE CURB, TYP.
5' GRASS STRIP BETWEEN NEW
PARKING LOT AND PATH
CONCRETE PAD
EXISTING MANHOLE TO BE REMOVED.
CAP CORP STOP, REMOVE FRAME AND LID,
REMOVE MANHOLE RISERS AND BACKFILL. DISCUSS
WITH ENGINEER AND CHAMPLAIN WATER DISTRICT
TC = 392.57
BC = 392.07
+ 391.10
+ 391.10
TC = 392.57
BC = 392.07
TC = 392.30
BC = 391.80
+ 391.39
392
39
2
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
20 40 60
15
°
±
VT Grid
Magnetic
Parking Area Plan
C2-02
06/18/2024
1" = 20'
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
1
0
0
'
W
E
T
L
A
N
D
B
U
F
F
E
R
UP
UP
UP
UP
UP
UP
D
G
W
W
394
394
3
9
4
394
394
3
9
4
394
39
4
393
393
39
3
393
393
393
393
3
9
3
39
3
3
9
2
392
39
2
39
2
392
392
392
392
39
2
392
392
392
392
39
2
392
392
39
2
3
9
2
39
1
391 39
1
39
1
391
391
391
3
9
1
391
391
391
391
3
9
1
391
391
39
1
391
391
391
391
390
390
390
39
0
390
39
0
390
390
390
390
390
3
9
0
390
390
3
9
0
390
3
9
0
390
390
390
390
390
3
9
0
389
389
389
389
3
8
9
389
389
389
389
389
389
389
38
9
38
9
3
8
9
389
389
389
389
3
8
9
3
8
9
388
38
8
388
388 388
388
388
388
388
38
8
388
38
8
388
3
8
8
38
8
3
8
8
388
388
388
388
38
8
387
387
387 387
387
387
387
387
387
387
3
8
7
38
7
3
8
7
387
387
387
38
7
3
8
7
387
386
386
386
38638
6
386
386
386
386
38
6
38
6
386
386
3863
8
6
386
3
8
6
385
385
385
385
3
8
5
385
385
385385
3
8
5
3
8
5
38
5
385
385
385
38
5
384
384
384384
384
3
8
4
384
384
384
384
3
8
4
38
4
384
384
384
3
8
4
383383
383
383
383
38
3
383
383
383
383
3
8
3
38
3
38
3
383
383
382
382 382
382
382
382
382 382
382
3
8
2
382
382
382
381
381 381
381
381
381
381 381 381
38
1
381
381
381
380
380
38
0
380
380
380
380 380 380
380
3
8
0
380
380
379
379
37
9
379
379
379
379 379
379
379
37
9
379
3
7
9
378378378
378
378
378
37
8
378378
3
7
8
378
377377
377
377377
377
377
377377
377
376 376 376
376 376
376 376
376
3
7
6
376
375
375 375
375 375
375 375
375
375
37
4
374
374 374
374 374
374 374
374
373
373 373
373
373 373
373
373
372
372
372372
372372372372
371
371
371371
371371371371370370370
370
370
370
3
7
0
370
3
7
0
369 369 369
369 369
369
369
3
6
9
368
36
8
368
368
368368368368
36
7
3
6
7
367
367
367367367367
366 366 366
366
366
366
3
6
6
3
6
6
3
6
6
365 365 365
365
365
365
36
5
36
5
365
364
3
6
4
3
6
4
364
364
364
364364364
3
6
3
3
6
3
3
6
3
363
363363
363
363
363
3
6
2
362
362
362
362
362
362
362
361
3
6
1
36
1
3
6
1
361
361
361361
360
3
6
0
360
360
360
360360
359
3
5
9
35
9
359
359
359
359
35
8
358
358
358
357
357
357
357
357
357
356
356
356
356
356
356
356
390
390
390
391
39
1
39
1
3
9
1
39
1
39
1
39
0
390
390
3
9
0
390
3
9
0
3
9
0
3
9
0
3
8
9
3
8
9
3
8
8
3
8
8
3
8
7
387
38
7
386
EX
I
S
T
I
N
G
HO
M
E
,
TY
P
.
D
50' A
N
R
C
L
A
S
S
I
I
W
E
T
L
A
N
D
B
U
F
F
E
R
SPEAR S
T
R
E
E
T
UP
S
W
E
P
T
L
A
N
E
PINNACL
E
D
R
I
V
E
TO
S
P
E
A
R
S
T
R
E
E
T
PARK
S
I
D
E
D
R
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 9020
CIVIL
ABI G A I L A .
D
E
R
Y
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
L ICEN S E D
Field Book:
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
60 120 180
15
°
±
VT Grid
Magnetic
Wetland Impact
Plan
C2-03
06/18/2024
1" = 60'
22-512
SCR
AAD
Hubbard Recreation
& Natural Area
Nowland Farm Road
South Burlington, VT
STATE WETLAND IMPACT KEY
PROPOSED CLASS II WETLAND BUFFER IMPACT = 4,441 SF
PROPOSED CLASS II WETLAND IMPACT = 283 SF
PROPOSED CLASS III WETLAND IMPACT = 1,784 SF
PROJECT LOCATION
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS II
WETLAND
CLASS III
WETLAND
CLASS III
WETLAND
CLASS III
WETLAND
CLASS III
WETLAND
CLASS III
WETLAND
CLASS III
WETLAND
EXISTING CLASS II WETLAND BUFFER IMPACT
PERMITTED UNDER INDIVIDUAL WETLAND PERMIT
#2014-085 = 3,195 SF