Loading...
HomeMy WebLinkAboutZP-24-253 - 0051 Barn Road 8/6/2024  VIA HAND‐DELIVERY    July 22, 2024    Betsy Brown  South Burlington Planning and Zoning   180 Market Street  South Burlington, VT 05403      Re:   Zoning Permit Application 51 Barn Road, South Burlington, VT 05403     Betsy,    Further to Final Plat Permit SD‐22‐10A, enclosed please find a zoning permit application  for 51 Barn Lane, South Burlington, Vermont 05403, Unit 38‐4 on the Final Plat/Site Plan  submitted as part of SD‐22‐10A.  Also enclosed please find:    1. A Water Allocation Application;  2. A Wastewater Allocation Application.  3. A wastewater Connection Application.   4. A site plan of the applicable area of the proposed home.   5. An architectural drawing showing compliance with plans proposed and permitted in SD‐ 22‐10A.     Regarding the height of the proposed structure, it is calculated per the approved  methodology and is listed on the zoning permit application as such.        Please contact us with any questions or concerns.            Sincerely,           Brandon Secl, Estimator   Property Owners Name:O'Brien Eastview Property Location:51 Barn Road Amount:19,754.85 Payment Type:check #2288 Date:7/30/2024 Code Zoning Permit (New Residential)ZP-24-253 zp Recording fee 13.00$ plus addition/alteration cost 5.00$ per $1,000 project cost -$ OR: plus 2840 0.45$ per sq. ft. 1,278.00$ plus 1792 0.20$ per sq. ft. 358.40$ plus 2 50.00$ per bay 100.00$ After-the fact of 50% [no NOV] or 100% [NOV] -$ Zoning Permit Total 1,749.40$ Sewer Allocation Fee WWA-24-140 #204 249.15 g.p.d x 16.17$ 4,028.76$ Bartlett Bay x Airport Parkway Impact Fee Administrative Fee #248 per application $100.00 School Impact Fee #222S 4 bedrooms 12,353.51$ Recreation Impact Fee* #220 /unit -$ South Village Recreation Impact Fee #243 /unit -$ Road Impact Fee #221 $963.73 /unit 963.73$ Fire Impact Fee #203 /unit -$ Police Impact Fee #222 $496.45 /unit 496.45$ Dorset Street Waterline Fee #230 /unit -$ Sewer Connection Inspection WWC-24-49 ww 63.00$ per connection 63.00$ *credit issued by City Council on 6/26/23 Total (Impact Fees + Permit) 19,754.85$ Planning & Zoning Invoice Residential Impact & Permit Fees garage bay(s) at Amount Due sq. ft building at sq. ft unfinished basement at IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A0.000 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t COVER SHEET SHEET INDEX SHEET NUMBER SHEET NAME ARCHITECTURAL A0.000 COVER SHEET A0.001 ARCHITECTURAL GENERAL NOTES A1.100 BASEMENT FLOOR PLAN - ELEVATION A A1.110 MAIN FLOOR PLAN - ELEVATION A A1.120 UPPER FLOOR PLAN - ELEVATION A A1.200 EXTERIOR ELEVATIONS - ELEVATION A A1.201 EXTERIOR ELEVATIONS - ELEVATION A A1.300 ROOF PLAN - ELEVATION A A1.400 BUILDING SECTIONS - ELEVATION A A1.401 BUILDING SECTIONS - ELEVATION A A1.402 BUILDING SECTIONS - ELEVATION A A1.500 STAIR SECTIONS A1.600 FLOOR PLAN OPTIONS - ALL ELEVATIONS A1.700 OPTIONAL DAYLIGHT BASEMENT A1.701 OPTIONAL DAYLIGHT BASEMENT A2.100 BASEMENT FLOOR PLAN - ELEVATION A A2.110 MAIN FLOOR PLAN - ELEVATION A A2.120 UPPER FLOOR PLAN - ELEVATION A A2.200 EXTERIOR ELEVATIONS - ELEVATION A A2.201 EXTERIOR ELEVATIONS - ELEVATION A A2.300 ROOF PLAN - ELEVATION A A2.400 BUILDING SECTIONS - ELEVATION A A2.401 BUILDING SECTIONS - ELEVATION A A2.402 BUILDING SECTIONS - ELEVATION A AD.1 ARCHITECTURAL DETAILS AD.2 ARCHITECTURAL DETAILS AD.3 ARCHITECTURAL DETAILS ELECTRICAL E1.100 BASEMENT ELECTRICAL PLAN - ELEVATION B E1.110 MAIN FLOOR ELECTRICAL PLAN - ELEVATION A E1.120 UPPER FLOOR ELECTRICAL PLAN - ELEVATION A E1.600 FLOOR PLAN OPTIONS - ELECTRICAL PLANS E2.100 BASEMENT ELECTRICAL PLAN - ELEVATION B E2.110 MAIN FLOOR ELECTRICAL PLAN - ELEVATION B E2.120 UPPER FLOOR ELECTRICAL PLAN - ELEVATION B STRUCTURAL S-0.1 GENERAL NOTES S-0.2 GENERAL NOTES S-0.3 GENERAL NOTES S-0.4 TYPICAL DETAILS S-0.5 TYPICAL DETAILS S-0.6 TYPICAL DETAILS S-0.7 TYPICAL DETAILS S-0.8 TYPICAL DETAILS S-0.9 TYPICAL DETAILS S-0.10 TYPICAL DETAILS S-0.11 TYPICAL DETAILS S-0.12 TYPICAL DETAILS S-1.0 FOUNDATION ELEVATION A S-1.1 FOUNDATION ELEVATION B S-2.0 FRAMING ELEVATION A S-2.1 FRAMING ELEVATION A S-2.2 FRAMING ELEVATION A S-2.3 FRAMING ELEVATION A S-2.4 FRAMING ELEVATION B S-2.5 FRAMING ELEVATION B S-2.6 FRAMING ELEVATION B S-2.7 FRAMING ELEVATION B S-2.8 OPTIONAL BASEMENT PLANS ALL ELEVATIONS S-3.0 SHEARWALL ELEVATION A S-3.1 SHEARWALL ELEVATION A S-3.2 SHEARWALL ELEVATION A S-3.3 SHEARWALL ELEVATION B S-3.4 SHEARWALL ELEVATION B S-3.5 SHEARWALL ELEVATION B TOTAL NUMBER OF SHEETS: 63 AREA SCHEDULE - STANDARD AREA NAME AREA ELEVATION A MAIN FLOOR LIVABLE 2021 SF UPPER FLOOR LIVABLE 819 SF LIVABLE 2840 SF 2-CAR GARAGE/STORAGE 568 SF PORCH 353 SF DECK 238 SF UNFINISHED BASEMENT 1771 SF COVERED DECK 247 SF NON-LIVABLE 3177 SF ELEVATION A 6017 SF ELEVATION B MAIN FLOOR LIVABLE 2021 SF UPPER FLOOR LIVABLE 819 SF LIVABLE 2840 SF UNFINISHED BASEMENT 1766 SF 2-CAR GARAGE/STORAGE 568 SF PORCH 349 SF DECK 238 SF COVERED DECK 247 SF NON-LIVABLE 3168 SF ELEVATION B 6008 SF Hillside at O'Brien Farm -51 Barn Road South Burlington, Vermont AREA SCHEDULE - OPTIONS AREA NAME AREA OPT. FINISHED BASEMENT FINISHED BASEMENT 1201 SF UNFINISHED 592 SF TOTAL 1792 SF Elevation A -Farmhouse GRADING PLAN LANDSCAPE PLAN UP 15 RISERS UNEXCAVATED 11' - 0"18' - 8"13' - 0"22' - 4" 65' - 0" 6' - 0"13' - 4"12' - 4"22' - 4" 6' - 0 " 13 ' - 0 " 5' - 0 " 6' - 0 " 2' - 0 " 2' - 0 " 29 ' - 0 " 32 ' - 0 " 17 ' - 0 " 5' - 0 " 62 ' - 0 " 62 ' - 0 " 1' - 6"8' - 4"2' - 0"8' - 4"2' - 2" 22 ' - 4 " 10 " 4' - 9 " 10"18' - 6" 001001 B-1 A2.400 A-2 A2.401 B-3 A2.402 26 ' - 0 " 4' - 0 " 3' - 1 1 " HRV 3 A1.500 1 A1.500 2 A1.500 65' - 0" 17' - 0"48' - 0" 12 ' - 0 " 8' - 6"8' - 6"24' - 11"18' - 1"5' - 0" 19 ' - 0 " 3050 DH 3050 DH FURNACE 28 6 8 UNEXCAVATED 8' -9" CLG UNFINISHED LOWER LEVEL 13' - 4"9' - 0" 6' - 8 " 10 " 8' - 0 " 15' - 0"41' - 0"9' - 0" 10' - 3"10' - 7"9' - 11"10' - 3" (2) 3068 FR DR (TEMP) 10"34' - 7 1/2"6' - 2"10" 12 ' - 0 " 16 ' - 2 " 3' - 9 1 / 2 " 7' - 6 1 / 2 " 1' - 1 1/2"10"3' - 4" 4 1/2" 8" 016 004 010 011 018 2X 6 W A L L 2X 6 W A L L 2X6 WALL 21' - 8 1/2"10" 10" 6' - 0 " 10 " 16 RISERS AS REQUIRED WH 21068 STORM SUMP 10" IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.100 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t BASEMENT FLOOR PLAN - ELEVATION A GENERAL FLOOR PLAN NOTES •MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) •WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. •PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. •ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. •PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. •SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. •PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. •ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) •ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) •CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. •ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. •ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. •FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. FLOOR PLAN KEYNOTES 001 DROP TOP OF FOUNDATION AT OVERHEAD GARAGE DOOR. 004 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS UNDER ACCESSIBLE ENCLOSED STAIRS. 010 HANDRAIL. 011 EMERGENCY EGRESS: WINDOW SHALL COMPLY WITH GOVERNING FIRE & BUILDING CODES. MAXIMUM SILL HEIGHT OF EGRESS WINDOWS SHALL BE NO MORE THAN 44" A.F.F. 016 LINE OF DECKING ABOVE. 018 3" RIGID INSULATION. Basement Plan - Elevation A AREA SCHEDULE - STANDARD - ELEV B AREA NAME AREA ELEVATION B MAIN FLOOR LIVABLE 2021 SF UPPER FLOOR LIVABLE 819 SF LIVABLE 2840 SF 2-CAR GARAGE/STORAGE 568 SF DECK 238 SF COVERED DECK 247 SF PORCH 349 SF UNFINISHED BASEMENT 1766 SF NON-LIVABLE 3168 SF ELEVATION B 6008 SF CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. DN DN 15 RISERS UP 17 RISERS DN 8080 OGD 3060 DH 2040 FX 2040 FX 2040 FX 2040 DH 3080 8080 OGD 3060 DH 1080 FX 18' - 8"13' - 0"22' - 4" 8"5' - 4"8"12' - 0"8"11' - 8"8" 6' - 4"10' - 4"6' - 4" 32 ' - 0 " 62 ' - 0 " 17 ' - 2 " 10 ' - 4 " 8" 5' - 4 " 9' - 7 " 2' - 0 " 13 ' - 0 " 6' - 0 " 2' - 2"3' - 8"1' - 8 1/2"2' - 0"2' - 1 1/2"2' - 8"2' - 8" 7' - 6 1/2"4' - 1 1/2" 11' - 8"5' - 4" 3' - 6"6' - 4"3' - 6"3' - 0"1' - 6" 17' - 0"13' - 4"11' - 8"23' - 0" 10' -0" CLG PORCH 62 ' - 0 " 2' - 0 " 29 ' - 0 " 65' - 0" 3' - 0 1/2" 4' - 1 1/2" 6' - 0 1/2"5' - 7 1/2" 11' - 0" 8" 4' - 4 " 8" 17 ' - 0 " 5' - 0 " 6' - 5 1 / 2 " 8" 5' - 4 " 11 ' - 6 1 / 2 " 2' - 0 " 11 ' - 0 " 22 ' - 4 " 146 130 126 126 B-1 A2.400 A-2 A2.401 B-3 A2.402 22 ' - 4 " 8" 10 ' - 4 " 2' - 0 " 6' - 0 1 / 2 " 6' - 0 1 / 2 " 2-STORY CLG FAMILY 2-STORY CLG DINING 2-STORY CLG KITCHEN M.K. O.E. 2-STORY CLG FOYER PANTRY PARCEL BEDROOM 4 LA U N D R Y OWNER'S BATH OWNER'S SUITE STORAGE W.I.C. BATH 2 2-CAR GARAGE 3060 DH 2040 DH 20 4 0 D H 30 6 0 D H (3)-3060 DH 40 2 6 F X OB S C U R E T E M P 3080 21 0 8 0 21 0 8 0 21080 21 0 8 0 21 0 8 0 21 0 8 0 F R DR ( T E M P ) 2680 21 0 8 0 26 8 0 6080 BP (2) 2080 21 0 8 0 21080 21 0 8 0 8" 11 ' - 4 " 10 ' - 4 " 3' - 6 1 / 2 " 5' - 1 1 / 2 " 19 ' - 0 " 3 A1.500 1 A1.500 2 A1.500 65' - 0" 17' - 0"48' - 0" 15' - 0"20' - 6"20' - 6"9' - 0" 2' - 5 1/2"38' - 5 1/2"7' - 1" 30 6 0 D H 14 ' - 1 0 " 3' - 0 1 / 2 " 8' - 1 1 " 2' - 1 0 1 / 2 " 7' - 7 " 8' - 6"8' - 6"9' - 0 1/2"13' - 6"7' - 6"8' - 5"2' - 3 1/2"4' - 9 1/2" 2' - 2 1 / 2 " 1' - 9 1 / 2 " 8"19' - 2"8" 4' - 0 " COVERED DECK (+16" SEAT) 12 ' - 0 " 8' - 0 " 1' - 6 " 3' - 7 1 / 2 " (2) 3068 FR DR (TEMP)(3)-3060 DH DECK 2X6 WALL 2X6 WALL 2X6 WALL 2' - 4 1 / 2 " 5' - 3 1 / 2 " 1' - 3 " 2' - 4 1 / 2 " 2' - 1 0 1 / 2 " 6' - 0 " 2' - 1 0 " 8" 3' - 9 1 / 2 " 8' - 1 1/2"3' - 1"5' - 4"11"1' - 3"11' - 2"11"4' - 3"5"3 1/2"6' - 3"5 1/2"2' - 3"3' - 2" 10"1' - 0" 5' - 10"2' - 4 1/2"4' - 3"2' - 10" 10'-0" CLG 2-STRY CLG 10 ' - 0 " CL G 2- S T R Y CL G 2-STRY CLG 10'-0" CLG 10'-0" CLG 2-STRY CLG 7' - 6 1/2"3' - 8"6' - 3"2' - 10"5' - 8"4' - 3"6' - 1 1/2" 4 1/2" 1' - 8"3' - 7 1/2"7' - 1"6' - 11"9' - 0" 14 ' - 1 0 " 3' - 7 1 / 2 " 1' - 1 0 " 5' - 3 " 3' - 5 1 / 2 " 7' - 3 " 4' - 1 " 16 ' - 2 " 6' - 8 " 2' - 1 0 " 15 ' - 8 1 / 2 " 5 1 / 2 " 130 138 129 131 131 131 131 131 11 8 11 9 12 0 10 8 12 2 10 8 10 8 10 9 10 8 10 9 10 4 10 1 10 2 103108 109 123 123 10 8 11 6 110 111 122 122110 131 114 11 1 11 1 FR E E S T A N D I N G TU B 124 107 10 9 10 8 10 8 127 128 133 133 133 133 145 10 ' - 0 " 2- S T R Y CL G CL G 2-STRY 10' - 0" CLG CLG 10 ' - 0 " 2 - S T R Y CL G C L G 10' - 0"2-STRY CLG CLG 10' - 0" 2-STRY CLG CLG 2- S T R Y 10 ' - 0 " CL G C L G 10 ' - 0 " 2 - S T R Y CL G C L G 2x 6 W A L L 9' - 1 0 1 / 2 " 2' - 6 " 3' - 1 1 / 2 " 3' - 0 1 / 2 " 6' - 8 " 2x6 WALL 5' - 1 0 1 / 2 " 8" 3' - 5 1 / 2 " 4' - 9 1 / 2 " 16 ' - 2 " 133 2x8 WALL 12 2 12 2 121 152 151 152150 152 150 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.110 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t MAIN FLOOR PLAN - ELEVATION A AREA SCHEDULE - STANDARD - ELEV B AREA NAME AREA ELEVATION B MAIN FLOOR LIVABLE 2021 SF UPPER FLOOR LIVABLE 819 SF LIVABLE 2840 SF 2-CAR GARAGE/STORAGE 568 SF DECK 238 SF COVERED DECK 247 SF PORCH 349 SF UNFINISHED BASEMENT 1766 SF NON-LIVABLE 3168 SF ELEVATION B 6008 SF FLOOR PLAN KEYNOTES 101 SINK W/ GARBAGE DISPOSAL. 102 DISHWASHER. 103 REFRIGERATOR. 104 RANGE W/ HOOD. 107 PANTRY SHELVES PER BUILDER SPEC. 108 BASE CABINETS. 109 UPPER CABINETS. 110 WATER CLOSET. 111 LAV. SINK. 114 SHOWER SEAT 18" A.F.F. 116 TUB/SHOWER (33X60). 118 WASHER. 119 DRYER. 120 LAUNDRY SINK. 121 LINE OF SHELF ABOVE. 122 ROD & SHELF. 123 ATTIC ACCESS. 124 HANDRAIL. 126 LINE OF OVERHEAD GARAGE DOOR IN OPEN POSITION. 127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD IN GARAGE AS REQUIRED BY CODE. 128 SLOPE GARAGE FLOOR 1/8" PER FOOT TOWARD GARAGE DOOR OPENING. 129 LINE OF FOUNDATION BELOW. 130 LINE OF SOFFIT ABOVE (REFER TO EXTERIOR ELEVATIONS FOR HEIGHTS AND DETAILS). 131 GYPSUM BOARD OPENING 8'-0" AT MAIN FLOOR & 7'-0" AT UPPER FLOOR. 133 LINE OF FRAMING ABOVE. 138 EXTERIOR GUARDRAIL W/ BALLUSTERS TO BE SPACED SUCH THAT 4" SPHERE CANNOT PASS BETWEEN BALUSTERS. 145 SHELF AT FINISH FLOOR LEVEL. 146 MAIL DROP. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. Main Floor Plan - Elevation A GENERAL FLOOR PLAN NOTES •MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) •WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. •PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. •ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. •PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. •SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. •PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. •ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) •ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) •CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. •ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. •ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. •FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. 2668 2668 2040 DH 2020 FX2020 FX2020 FX (2)-3050 DH (2)-3050 DH 3' - 9 " 11 ' - 6 1 / 2 " 5' - 0 " 17 ' - 0 " 62 ' - 0 " 13' - 6 1/2"9' - 0" 2' - 8"2' - 8" 2' - 9 1/2"3' - 0"3' - 0"3' - 4" 19 ' - 0 " 62 ' - 0 " 5' - 10"5' - 10" 11' - 8"5' - 4"13' - 4"12' - 1 1/2" 6' - 8"6' - 8" 2' - 0 " 16 ' - 2 " 9' - 6 " 4' - 2"13' - 6 1/2" 4' - 1 1/2" 5' - 0 " 6' - 0 " 13 ' - 0 " 11 " B-1 A2.400 A-2 A2.401 B-3 A2.402 3' - 1 1 " 5' - 7 " 2' - 0 " 11 ' - 0 " 65' - 0" 11' - 0"18' - 8"13' - 0"22' - 4" 28 ' - 0 " 29 ' - 0 " 2' - 0 " 22 ' - 4 " 25 ' - 8 " OPEN TO BELOW BEDROOM 3 5068 BP 5068 BP 3030 FX 3030 FX 3030 FX 3030 FX 3030 FX 20 2 0 F X 8' - 0" H . H . 20 2 0 F X 8' - 0" H . H . 20 2 0 F X 8' - 0" H . H . 26 6 8 24682668 2668 BATH 3 BEDROOM 2 LOFT P.O. 3 A1.500 1 A1.500 2 A1.500 OPEN TO BELOW 30 5 0 D H 56' - 0"9' - 0" 12' - 8 1/2"4' - 3 1/2" 1' - 0"1' - 5 1/2"36' - 6 1/2" 6' - 0 1/2"6' - 0"6' - 0"6' - 0"6' - 0"6' - 6" 2' - 4 1 / 2 " 2' - 4 1 / 2 " 11 ' - 8 1 / 2 " 8' - 9 " 2' - 1 1 1 / 2 " 4' - 0 " 4' - 0 " 4' - 5 " 8' - 0 " 4' - 0 " 12 ' - 0 " 35' - 6"20' - 6"9' - 0" 11 0 11 1 11 1 116 122 122 123 132 132 131 124 11 7 134 134 7' - 7 1/2"3' - 10 1/2"5' - 1 1/2"2' - 10"16' - 4"2' - 6" 4' - 6 1 / 2 " 3 1 / 2 " 4' - 1 " 4' - 5 1 / 2 " 8' - 5 " 3' - 3 1 / 2 " 7' - 3 " 4' - 1 " 16 ' - 2 " 11' - 6"2' - 3 1/2"3' - 1"7"12' - 8 1/2"8' - 2" 65' - 0" 131 2x 6 W A L L 151 150 152 152 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.120 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t UPPER FLOOR PLAN - ELEVATION A AREA SCHEDULE - STANDARD - ELEV B AREA NAME AREA ELEVATION B MAIN FLOOR LIVABLE 2021 SF UPPER FLOOR LIVABLE 819 SF LIVABLE 2840 SF 2-CAR GARAGE/STORAGE 568 SF DECK 238 SF COVERED DECK 247 SF PORCH 349 SF UNFINISHED BASEMENT 1766 SF NON-LIVABLE 3168 SF ELEVATION B 6008 SF FLOOR PLAN KEYNOTES 110 WATER CLOSET. 111 LAV. SINK. 116 TUB/SHOWER (33X60). 117 LINEN SHELVES PER BUILDER SPEC. 122 ROD & SHELF. 123 ATTIC ACCESS. 124 HANDRAIL. 131 GYPSUM BOARD OPENING 8'-0" AT MAIN FLOOR & 7'-0" AT UPPER FLOOR. 132 HALF WALL @ 36" A.F.F. W/ WOOD CAP. 134 LINE OF FRAMING BELOW. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. Upper Floor Plan - Elevation A GENERAL FLOOR PLAN NOTES •MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) •WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. •PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. •ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. •PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. •SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. •PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. •ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) •ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) •CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. •ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. •ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. •FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. UNEXCAVATED 8' -9" CLG BASEMENT BEDROOM 8' -9" CLG BONUS ROOM 8' -0" CLG BASEMENT BATH8' -9" CLG MECHANICAL 8' -9" CLG STORAGE 8' -9" CLG STORAGE UNEXCAVATED 21068 21068 21068 21 0 6 8 20 6 8 21 0 6 8 60 6 8 B P 11 1 11 0 116 12 2 11 7 011 004 018 2X 6 W A L L 3"15' - 5 1/2"2' - 4 1/2"45' - 0"3" 9' - 11"1' - 10"5' - 4"1' - 3 1/2"10' - 10"5' - 5"2' - 5"3' - 9" 10" 12' - 8 1/2" 15 ' - 9 " 3' - 1 0 1 / 2 " 3' - 3 1 / 2 " 3' - 8 1 / 2 " 2' - 3 1 / 2 " 3" 2' - 0 " 13 ' - 0 " 3" 3' - 3 " 5' - 2 1 / 2 " 10 "3' - 1 0 1 / 2 " 2' - 1 1 " 8' - 1 0 " 4' - 0 " 5' - 2 1 / 2 " 3' - 5 1 / 2 " 7' - 6 1 / 2 " 3' - 6 " 16 ' - 5 1 / 2 " 8' - 4 1 / 2 " 16 ' - 5 1 / 2 " 2X 6 W A L L 2X 6 W A L L 2X6 WALL 16 RISERS AS REQUIRED WH STORM SUMP 21068 152 151 150 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 7/ 1 9 / 2 0 2 4 1 1 : 3 7 : 0 6 A M C: \ U s e r s \ c h a r l o t t e \ O ' B r i e n B r o t h e r s A g e n c y , I n c \ H o m e B u i l d i n g - N e i g h b o r h o o d s \ H i l l s i d e E a s t \ R e v i t P l a n s \ S F - 5 _ R 2 0 1 9 . r v t A1.600 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t FLOOR PLAN OPTIONS - ALL ELEVATIONS 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 FLOOR PLAN KEYNOTES 004 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS UNDER ACCESSIBLE ENCLOSED STAIRS. 011 EMERGENCY EGRESS: WINDOW SHALL COMPLY WITH GOVERNING FIRE & BUILDING CODES. MAXIMUM SILL HEIGHT OF EGRESS WINDOWS SHALL BE NO MORE THAN 44" A.F.F. 018 3" RIGID INSULATION. 110 WATER CLOSET. 111 LAV. SINK. 116 TUB/SHOWER (33X60). 117 LINEN SHELVES PER BUILDER SPEC. 122 ROD & SHELF. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. GENERAL FLOOR PLAN NOTES •MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) •WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. •PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. •ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. •PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. •SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. •PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. •ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) •ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) •CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. •ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. •ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. •FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. NOTE: SEE STANDARD FLOOR PLANS, ELECTRICAL PLANS, ROOF PLANS, AND ELEVATIONS, FOR INFORMATION NOT SHOWN, IN AREAS ADJACENT TO OPTIONS, THAT DOES NOT CHANGE. Floor Plan Options All Elevations Similar Optional Finish Basement Plan MAIN FLOOR MAIN PLATE 10 ' - 1 1 / 8 " UPPER FLOOR UPPER PLATE 9' - 1 1 / 8 " TOP OF FOUNDATION 10 12 10 12 10 12 10 12 4 12 10 12 10 12 4 12 AD.3 2 4 AD.2 7 AD.1 3 AD.1 1 AD.2 11 AD.2 10 AD.2 211 212 205 214 241 211 212 202 213 217 222 211 212 MAIN FLOOR MAIN PLATE 10 ' - 1 1 / 8 " UPPER FLOOR UPPER PLATE 9' - 1 1 / 8 " TOP OF FOUNDATION BASEMENT FLOOR 4 12 8' - 8 " 4 124 12 222 211 212 223 202 213 214 11 AD.2 7 AD.1 7 AD.2 3 AD.1 9' - 0 " 216 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.200 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t EXTERIOR ELEVATIONS - ELEVATION A EXTERIOR ELEV KEYNOTES 202 6" LAP SIDING. 203 SHAKE SIDING. 205 BOARD & BATTEN. 206 STONE VENEER. 207 STONE CAP. 211 1x8 FASCIA/RAKE. 212 5/4x6 FRIEZE TRIM. 213 5/4x6 CORNER TRIM. 214 5/4x4 TRIM. 215 5/4x6 TRIM. 216 5/4x8 TRIM. 217 5/4x10 TRIM. 222 COMPOSITION SHINGLES. 223 RAILING PER BUILDERS SPEC. 241 MAIL DROP. Front Elevation Rear Elevation Elevation A -Farmhouse EXTERIOR ELEVATION NOTES •REFER TO GENERAL NOTES AND DETAIL SHEETS FOR TYPICAL REQUIREMENTS AND MATERIALS SPECIFIC TO THIS PROJECT. •GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN. BUILDER SHALL VERIFY AND COORDINATE PER ACTUAL SITE CONDITIONS. •BUILDER TO PROVIDE ROOF AND SOFFIT VENTS SPECIFIED BY ATTIC VENT SCHEDULE, OR APPROVED EQUAL. •PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER. •INSTALL ALL PRE-MANUFACTURED MATERIALS PER MANUFACTURER'S REQUIREMENTS, RECOMMENDATIONS, AND SPECIFICATIONS. INSTALLATION REQUIREMENTS TO BE PROVIDED BY BUILDER. ALL ITEMS SHOWN ARE STANDARD U.N.O. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. MAIN FLOOR MAIN PLATE 10 ' - 1 1 / 8 " UPPER FLOOR UPPER PLATE 9' - 1 1 / 8 " TOP OF FOUNDATION BASEMENT FLOOR 8' - 8 " 6 12 6 12 4 12 6 12 4 124 12 3 AD.1 1 AD.2 10 AD.2 7 AD.1 11 AD.2 AD.3 2 211 212 202 214 223 205 222 217 213 9' - 0 " 9' - 0 " 215 216 26 .3 ' PCG MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE 10 ' - 1 1 / 8 " 9' - 1 1 / 8 " TOP OF FOUNDATION BASEMENT FLOOR 8' - 8 " 6 12 6 12 6 12 4 12 4 124 12 222 211 212 202 223 205 213 4 AD.2 1 AD.2 10 AD.2 7 AD.1 11 AD.2 217 AD.3 2 9' - 0 " 214 216 215 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.201 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t EXTERIOR ELEVATIONS - ELEVATION A EXTERIOR ELEV KEYNOTES 202 6" LAP SIDING. 203 SHAKE SIDING. 205 BOARD & BATTEN. 206 STONE VENEER. 207 STONE CAP. 211 1x8 FASCIA/RAKE. 212 5/4x6 FRIEZE TRIM. 213 5/4x6 CORNER TRIM. 214 5/4x4 TRIM. 215 5/4x6 TRIM. 216 5/4x8 TRIM. 217 5/4x10 TRIM. 222 COMPOSITION SHINGLES. 223 RAILING PER BUILDERS SPEC. 241 MAIL DROP. Left Elevation Right Elevation Elevation A -Farmhouse EXTERIOR ELEVATION NOTES •REFER TO GENERAL NOTES AND DETAIL SHEETS FOR TYPICAL REQUIREMENTS AND MATERIALS SPECIFIC TO THIS PROJECT. •GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN. BUILDER SHALL VERIFY AND COORDINATE PER ACTUAL SITE CONDITIONS. •BUILDER TO PROVIDE ROOF AND SOFFIT VENTS SPECIFIED BY ATTIC VENT SCHEDULE, OR APPROVED EQUAL. •PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER. •INSTALL ALL PRE-MANUFACTURED MATERIALS PER MANUFACTURER'S REQUIREMENTS, RECOMMENDATIONS, AND SPECIFICATIONS. INSTALLATION REQUIREMENTS TO BE PROVIDED BY BUILDER. ALL ITEMS SHOWN ARE STANDARD U.N.O. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. 4: 1 2 4:12 6: 1 2 4: 1 2 4: 1 2 6: 1 2 6: 1 2 10:12 4:12 6: 1 2 6: 1 2 CRICKET 4:12 10:12 10:12 4: 1 2 TYP. 1' - 0" EAVE TYP. 1' - 0" RAKE 6:12 4:12 4:12 10:12 10:12 10:12 68 SF ZONE 2 242 SF ZONE 3 1715 SF ZONE 1 1151 SF ZONE 4 2' - 0" B-1 A2.400 A-2 A2.401 B-3 A2.402 BE L O W IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.300 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t ROOF PLAN - ELEVATION A Roof Plan NOTE: * REQUIRED NET FREE AREAS ARE CALCULATED BY MULTIPLYING THE ACTUAL ATTIC AREA (SQ FT) BY 1/300. 40%-50% OF TOTAL NET FREE VENTED AREA IS REQUIRED AT THE RIDGE (HIGH) WITH REMAINING REQUIRED IN THE SOFFIT (LOW). WHEN NO "HIGH / LOW" VENTING IS PROVIDED, THE REQUIRED NET FREE AREA IS 1/150 OF THE ACTUAL AREA. ATTIC VENTILATION SCHEDULE - ELEVATION B ZONE ATTIC AREA VENT RATIO REQUIRED UPPER VENTILATION REQUIRED LOWER VENTILATION ZONE 1 1715 SF 1 / 300 2.86 SF 2.86 SF ZONE 2 68 SF 1 / 150 0.45 SF 0.00 SF ZONE 3 242 SF 1 / 300 0.40 SF 0.40 SF ZONE 4 1151 SF 1 / 300 1.92 SF 1.92 SF CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. Elevation A -Farmhouse MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR 9' - 1 1/8" HEEL 4" HEEL 1' - 4" DINING COVERED DECKM.K.2-CAR GARAGE UNFINISHED LOWER LEVEL 6 12 6 12 4 12 4 12 ROOF TRUSS @24" O.C. 12' - 0" B1 D1 C1 HEEL 4" 4' - 0" ROOF TRUSS @24" O.C. 22' - 4" ROOF TRUSS @24" O.C. 25' - 8" A1 60' - 0" 10' - 1 1/8" 8' - 8" IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.400 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t BUILDING SECTIONS - ELEVATION A Building Sections Elevation A -Farmhouse CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. Section B-1 MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR UNFINISHED LOWER LEVEL FOYER FAMILY DECK LOFT HEEL 4" GIRDER TRUSS HEEL 1' - 4" 6 12 6 12 4 12 B1 C1 C1 D1 4' - 0" 8' - 8" PORCH 5' - 0" ROOF TRUSS @24" O.C. 13' - 7" ROOF TRUSS @24" O.C. 31' - 5" 50' - 0" 9' - 1 1/8" 10' - 1 1/8" IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.401 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t BUILDING SECTIONS - ELEVATION A Building Sections Elevation A -Farmhouse CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. Section B-2 MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR HEEL 1' - 4" 6 12 6 12 4 12 4 12 HEEL 4" P.O.LOFT BATH 3 W.I.C.OWNER'S SUITE UNFINISHED LOWER LEVEL ROOF TRUSS @24" O.C. 26' - 0" ROOF TRUSS @24" O.C. 4' - 0" HEEL 1' - 4" 4' - 0" 8' - 8" B1 C1 C1 D1 PORCH A1 2' - 10 1/2"16' - 1 1/2" 49' - 0" 10' - 1 1/8" 9' - 1 1/8" IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A2.402 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t BUILDING SECTIONS - ELEVATION A Building Sections Elevation A - Farmhouse CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. Section B-3 SD C O WP SD C O WP GF C I WP / G F C I 3 HRV FURNACE TO FIXTURE ABOVE 3 3 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 7/19/2024 11:37:13 AM C:\Users\charlotte\O'Brien Brothers Agency, Inc\Home Building - Neighborhoods\Hillside East\Revit Plans\SF-5_R2019.rvt E2.100 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t BASEMENT ELECTRICAL PLAN - ELEVATION B 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 GENERAL ELECTRICAL NOTES A.PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B.PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C.ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D.HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E.ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F.ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G.FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H.KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J.ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K.CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L.SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M.ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N.ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O.PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P.PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q.OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R.LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S.UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T.NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U.CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V.ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER Basement Electrical Plan - Elevation A WP WP WP SD CO SD CO SD SD D WP WP WP WP D 30 A 50 A CH WP WP WP EV SD CO SD CO SD SD D WP WP WP WP D 30 A 50 A CH EV WP/GFCI GFCI GF C I GFCI GFCI GFCI GFCI GFCI 3 WP/GFCI WP / G F C I GF C I GF C I GFCI GF C I GFCI GF C I 3 GFCI GFCI UP TO FIXTURE UP TO FIXTURE DN TO SWITCH 220V +84" AFF UP TO FIXTURES UP TO FIXTURE 3 3 3 3 2' - 4" 3 UP TO FIXTURE 3 3 GFCI IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 7/19/2024 11:37:15 AM C:\Users\charlotte\O'Brien Brothers Agency, Inc\Home Building - Neighborhoods\Hillside East\Revit Plans\SF-5_R2019.rvt E2.110 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t MAIN FLOOR ELECTRICAL PLAN - ELEVATION B 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 GENERAL ELECTRICAL NOTES A.PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B.PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C.ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D.HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E.ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F.ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G.FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H.KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J.ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K.CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L.SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M.ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N.ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O.PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P.PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q.OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R.LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S.UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T.NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U.CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V.ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER Main Floor Electrical Plan - Elevation A SD CO SD SD SD CO SD SD TO SWITCH BELOWDN TO SWITCH DN TO SWITCH 33 DN TO SWITCH PEND GFCI GFCI 3 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 7/19/2024 11:37:16 AM C:\Users\charlotte\O'Brien Brothers Agency, Inc\Home Building - Neighborhoods\Hillside East\Revit Plans\SF-5_R2019.rvt E2.120 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t UPPER FLOOR ELECTRICAL PLAN - ELEVATION B 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 GENERAL ELECTRICAL NOTES A.PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B.PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C.ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D.HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E.ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F.ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G.FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H.KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J.ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K.CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L.SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M.ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N.ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O.PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P.PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q.OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R.LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S.UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T.NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U.CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V.ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER Upper Floor Electrical Plan - Elevation A WP SD CO SD TO FIXTURE ABOVE GF C I 3 3 3 WP/GFCI 3 3 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 7/19/2024 11:37:13 AM C:\Users\charlotte\O'Brien Brothers Agency, Inc\Home Building - Neighborhoods\Hillside East\Revit Plans\SF-5_R2019.rvt E1.600 PLAN SF-5 SF210303.00 JY/MB ST JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m 51 B a r n R o a d So u t h B u r l i n g t o n , V e r m o n t FLOOR PLAN OPTIONS - ELECTRICAL PLANS 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 GENERAL ELECTRICAL NOTES A.PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B.PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C.ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D.HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E.ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F.ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G.FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H.KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J.ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K.CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L.SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M.ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N.ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O.PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P.PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q.OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R.LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S.UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T.NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U.CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V.ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER Opt. Finish Basement -Electrical Plan NOTE: SEE STANDARD FLOOR PLANS, ELECTRICAL PLANS, ROOF PLANS, AND ELEVATIONS, FOR INFORMATION NOT SHOWN, IN AREAS ADJACENT TO OPTIONS, THAT DOES NOT CHANGE.