Loading...
HomeMy WebLinkAboutPermit Permanent Sign SN-24-21 - UVM Health Network24 21 X $110.00 7/2/2024 D D D W W W W W W PS ADM S S S F H A FH A FH A CO THE UNIVERSITY OF VERMONT MEDICAL CENTER LOT 5 / 350 TILLEY DRIVE 14.36 AC. 80' CITY OF SOUTH BURLINGTON PUBLIC RIGHT-OF-WAY 50' FRONT SETBACK 35' SIDE SETBACK EXISTING TREE TO REMAIN. PRUNE AS NEEDED FOR SIGN VISIBILITY 34 0 340 34 1 341 NEW 1" PVC ELECTRIC CONDUIT (SEE ELEC PLANS) NEW SIGN 1 inch = 20 feet WARNING: FATALLY TOXIC GASES MAY BE PRESENT IN UNDERGROUND PIPING SYSTEMS AND WASTE SYSTEM STRUCTURES. GENERAL NOTES: 1)EXISTING FEATURES AND TOPOGRAPHY DEPICTED ON THIS PLAN ARE BASED ON THE FOLLOWING: A.PLAN ENTITLED "MOUNTAIN VIEW OFFICE PARK, LOT 4 SITE DEVELOPMENT, SITE PLAN", SHEET #2, DATED 12/06/05, LAST REVISED 04/21/08, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC. B.PLAN ENTITLED "MOUNTAIN VIEW OFFICE PARK, LOT 4 MRI ADDITION, SITE PLAN", SHEET C-1, DATED 07/14/08, LAST REVISED 09/29/08, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC. C.PLAN ENTITLED "MOUNTAIN VIEW OFFICE PARK - LOT 5, 194 TILLEY DRIVE SITE DEVELOPMENT, OVERALL SITE PLAN", SHEET 1, DATED 05/16/2018, LAST REVISED 10/22/2018, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC. D.PLAN ENTITLED "MOUNTAIN VIEW OFFICE PARK - LOT 5, 194 TILLEY DRIVE SITE DEVELOPMENT, SITE PLAN" SHEET 2, DATED 05/16/2018, LAST REVISED 10/22/2018, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC. E.FIELD SURVEY PERFORMED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC. DURING MAY, 2021. F.DIGITAL ELEVATION MODEL LIDAR DATA PROVIDED BY THE STATE OF VERMONT OPEN GEODATA PORTAL. G.PLAN ENTITLED "LANDSCAPE PLAN, 350 TILLEY DRIVE, SOUTH BURLINGTON, VERMONT" PREPARED BY VHB, SHEET LA-1.00, DATED JUNE 24, 2021. 2)EXISTING TOPOGRAPHY SHOWN ON THIS PLAN IN THE DEVELOPED AREA ON LOT 5 ARE BASED ON DESIGN CONTOURS FROM REFERENCE 1)C AND 1)D ABOVE. 3)TILLEY DRIVE UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON A PLAN ENTITLED "TILLEY II SUBDIVISION, ROADWAY PLAN VIEW", SHEET #2, DATED 05/26/04 AND LAST REVISED 04/04/05, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC. 4)PROPERTY LINE LOCATIONS AND DIMENSIONS SHOWN ON THIS PLAN ARE BASED ON A PLAN ENTITLED "BOUNDARY PLAT, MOUNTAIN VIEW OFFICE PARK, TILLEY 2 SUBDIVISION, TILLEY DRIVE, SOUTH BURLINGTON, VERMONT", SHEET 1 OF 1, DATED 07/29/04, LAST REVISED 06/09/2021, PREPARED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC. 5)ALL UTILITIES SHOWN ON THIS PLAN ARE BASED ON THE BEST AVAILABLE INFORMATION AND ARE APPROXIMATE. THE CONTRACTOR SHALL EXCAVATE WITH CAUTION AT ALL TIMES. ANY UTILITIES DAMAGED OR DISTURBED BY THE CONTRACTOR DURING THE PERFORMANCE OF THE WORK SHALL BE REPAIRED OR REPLACED IN A TIMELY FASHION AT THE EXPENSE OF THE CONTRACTOR. 6)WETLANDS SHOWN ON THIS PLAN ON LOT 5 WERE DELINEATED BY GILMAN & BRIGGS ENVIRONMENTAL ON 09/18/2017 AND VERIFIED BY THE DISTRICT WETLAND ECOLOGIST ON 11/08/2017. 7)THE DESIGN ON THESE PLANS SHALL BE INSPECTED BY DONALD L. HAMLIN CONSULTING ENGINEERS, INC. (DLHCE) TO ENSURE COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND ISSUED PERMITS. 8)THE CONTRACTOR SHALL INSTALL AND MAINTAIN EROSION PREVENTION AND SEDIMENT CONTROL MEASURES THROUGHOUT THE DURATION OF THE CONSTRUCTION IN ACCORDANCE WITH THE "LOW RISK SITE HANDBOOK FOR EROSION PREVENTION AND SEDIMENT CONTROL", LATEST EDITION, AS PUBLISHED BY THE VERMONT DEPARTMENT OF ENVIRONMENTAL CONSERVATION. ALL AREAS OF DISTURBANCE SHALL BE STABILIZED WITHIN 7 CALENDAR DAYS OF INITIAL DISTURBANCE. AFTER THIS TIME, ANY DISTURBANCE IN THE AREA MUST BE STABILIZED AT THE END OF EACH WORK DAY, UNLESS; WORK IS TO CONTINUE IN THE AREA WITHIN THE NEXT 24 HOURS AND THERE IS NO PRECIPITATION FORECAST FOR THE NEXT 24 HOURS; OR THE WORK IS BEING PERFORMED IN A SELF-CONTAINED EXCAVATION WITH A DEPTH OF 2 FEET OR GREATER (i.e. HOUSE FOUNDATION, UTILITY TRENCHES). ALL AREAS OF DISTURBANCE SHALL HAVE PERMANENT STABILIZATION WITHIN 48 HOURS OF REACHING FINAL GRADE. 9)THE CONTRACTOR SHALL NOTIFY THE CITY OF SOUTH BURLINGTON PUBLIC WORKS DEPARTMENT PRIOR TO ANY EXCAVATION SUCH THAT MUNICIPAL UTILITIES MAY BE LOCATED WITHIN THE LIMITS OF CONSTRUCTION. 10)NORTH ORIENTATION IS REFERENCED TO THE VERMONT STATE PLANE COORDINATE SYSTEM (NAD83). THE VERTICAL ELEVATIONS ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88). DLHCE JPK JPK 06/11/2024 1" = 20' 23-345 1 MOUNTAIN VIEW OFFICE PARK - LOT 5 350 TILLEY DRIVE BUILDING EXPANSION PROPOSED NEW SIGN THE UNIVERSITY OF VERMONT MEDICAL CENTER 1519 SHELBURNE ROAD SOUTH BURLINGTON, VT 05403 06/25/2024 REVISE NOTE TO LEAVE EXISTING TREE & PRUNE AS NEEDED MOVE NEW SIGN SOUTH APPROXIMATELY 1.0', JPK 604020020 THE CONTRACTOR SHALL NOTIFY "DIGSAFE" AT 1-888-344-7233 PRIOR TO ANY EXCAVATION AT LOCATIONS WHICH MAY BE IN THE IMMEDIATE VICINITY OF UNDERGROUND UTILITIES. VICINITY MAP 1" = 400' PROPOSED PROJECT AREA TILLEY DRIVE VT R O U T E 1 1 6 I-89 NORT H B O U N D I-89 SOU T H B O U N D 350 TILLEY DRIVE 350 Tilley Drive Dermatology Ophthalmology 1" 4' - 1 0 " 6'- 1 0 " 1' - 1 0 " 6" 1' - 8 " 4'-0" 3'-6" 1' - 1 0 " 6'- 1 0 " 1' - 8 " 1" 3' - 3 " REINFORCED CONCRETE SONO-TUBE FOOTING. ALL REBAR MIN. 3" COVER (TYP.) 1'- 0 " 6" 6" ALUMINUM BASE SHROUD 6" 4' - 0 " M I N . 6" 1' - 1 0 " 6'- 1 0 " 1' - 8 " 1" 3' - 3 " 6" R 2 1 2" 234" CONNECT CONDUIT SWEEP TO TRENCHED POWER CONDUIT LED BAFFLES (TYP.) PUSH-THROUGH ACRYLIC LETTERS FLUSH TO FACE W/ WHITE LED BACKLIGHTING 3-1/2" x 3-1/2" x .25" TUBE STEEL STRUCTURAL SUPPORT PUSH-THROUGH ACRYLIC LETTERS W/ COLOR TRANSLUCENT VINYL DECAL FACE, PROTRUDING 12" , W/ WHITE LED BACKLIGHTING EQUAL EQUAL 1' - 6 " M I N . 4' - 1 0 " 1'-312" 10"+/- 2'-0" DIA.2'-0" DIA. EQ.EQ. 4' - 0 " M I N . SK-01 3 SK-01 2 1 1/2" = 1' - 0" EXTERIOR SIGN ELEVATION 2 1/2" = 1' - 0" ELEVATION DETAIL 3 1/2" = 1' - 0" SECTION DETAIL 350 Tilley Drive Dermatology Ophthalmology SITE MARKER: ·TOTAL SIGN AREA W/O ALUMINUM BASE: 22.8 S.F. ·INTERNALLY ILLUMINATED ·DIRECTIONAL OR INFORMATION COPY ·GEO-LOCATOR PRESENT ·ALUMINUM SHROUD W/ REINFORCED CONCRETE BASE 4'-6" 3" GRADE 3" 6" REINFORCED CONCRETE SLAB W/ REBAR 12" O.C., 3" ABOVE GRADE. AS NOTED Sheet No: Date: Scale: 3/4/21 SK-01 Drawn By:- TILLEY DRIVE PROPOSED EXTERIOR SIGN DERMATOLOGY - OPHTHALMOLOGY 350 TILLEY DRIVE DateRevision No. 4/12/2024UVMMC STANDARDS COORD.1 © 2013 BrandActive. All rights reserved. All ideas, designs, arrangements and plans indicated or presented by these drawings are owned by and are the property of the Owner, and were created, evolved and developed for the use on and in connection with the specific project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of BrandActive and the Owner. The Owner may have additional requirements or restrictions for which the Contractor is also responsible. The acceptance of these drawings by vendor, bidders, fabricators, or Contractors and their agents constitutes agreement to the following. These design intent drawings are for the sole purpose of design intent only and not intended for construction purposes. Resulting working drawings, shop drawings and contract documents including permit documents are the sole responsibility of the Contractor in every respect. Check by: Date: Approved Date: Drawn by: Date: Approved: File Name: Rev No. Date: By:Project:Client: 24 Sheet:Sign Program Prepared by BrandActive TIER 2 - MONUMENT SIGN RENDERING Tier 2 - Monument Rendering v1.4 22 Jan 2015 MKA. Roldan 08 Dec 14 M. Reece 08 Dec 14Ground Signs © 2013 BrandActive. All rights reserved. All ideas, designs, arrangements and plans indicated or presented by these drawings are owned by and are the property of the Owner, and were created, evolved and developed for the use on and in connection with the specific project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of BrandActive and the Owner. The Owner may have additional requirements or restrictions for which the Contractor is also responsible. The acceptance of these drawings by vendor, bidders, fabricators, or Contractors and their agents constitutes agreement to the following. These design intent drawings are for the sole purpose of design intent only and not intended for construction purposes. Resulting working drawings, shop drawings and contract documents including permit documents are the sole responsibility of the Contractor in every respect. Check by: Date: Approved Date: Drawn by: Date: Approved: File Name: Rev No. Date: By:Project:Client: 40 Sheet:Sign Program Prepared by BrandActive D1L-I-G Front View Scale: N.T.S. D2L-I-G Front View Scale: N.T.S. Plan View Scale: N.T.S. Plan View Scale: N.T.S. Visitor Parking Medical OceBuildings Fitzpatrick CancerCenter EMERGENCY XXX Street Name Rehabilitation &Occupational Medicine Orthopedics Surgery Aquatics Family Medicine Pediatric Primary Care Directional Signs General Specifications • Internally illuminated • Directional or information copy • Granite base • Geo-locator may be present v1.4 22 Jan 2015 MKA. Roldan 08 Dec 14 M. Reece 08 Dec 14Ground Signs © 2013 BrandActive. All rights reserved. All ideas, designs, arrangements and plans indicated or presented by these drawings are owned by and are the property of the Owner, and were created, evolved and developed for the use on and in connection with the specific project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of BrandActive and the Owner. The Owner may have additional requirements or restrictions for which the Contractor is also responsible. The acceptance of these drawings by vendor, bidders, fabricators, or Contractors and their agents constitutes agreement to the following. These design intent drawings are for the sole purpose of design intent only and not intended for construction purposes. Resulting working drawings, shop drawings and contract documents including permit documents are the sole responsibility of the Contractor in every respect. Check by: Date: Approved Date: Drawn by: Date: Approved: File Name: Rev No. Date: By:Project:Client: 23 Sheet:Sign Program Prepared by BrandActive TIER 1 - MONUMENT SIGN RENDERING Tier 1 - Monument Rendering v1.4 22 Jan 2015 MKA. Roldan 08 Dec 14 M. Reece 08 Dec 14Ground Signs LEVEL 1 100' -0" LEVEL 2 113' -4" ROOF FRAMING 126' -8" A A3.01 A A3.01 GRANITE HORIZONTAL BANDING SCHED. GLAZING SCHEDULED MASONRY SILL 123456 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1A1A1A1A1A1A1A1A1A1A1 A2 ELEVATION NORTH SECONDARY PACKAGED ROOF TOP UNIT, REFERENCE MECHANICAL DRAWINGS, TYPICAL APPROXIMATE GRADE 6'-0" 2'-8" 4'-8" 6'-0" 2'-8" FOUNDATION & FOOTINGS BEYOND, REF. STRUCTURAL A2 SECONDARY ROOF DRAIN, REF. PLUMBING DRAWINGS SECONDARY ROOF DRAIN, REF. PLUMBING DRAWINGS C.J.C.J.C.J.C.J.C.J. LEVEL 1 100' -0" LEVEL 2 113' -4" ROOF FRAMING 126' -8" B A3.01 B A3.01 C A3.01 C A3.01 16 15 14 13 12 11 10 9 8 3 A4.03 3 A4.03 PACKAGED ROOF TOP UNIT, REFERENCE MECHANICAL DRAWINGS, TYPICAL PACKAGED ROOF TOP UNIT, REFERENCE MECHANICAL DRAWINGS, TYPICAL A1 A1 A1 A1A1 A1A1 A1A1 A1A1 A1A1 A1A1 A1A1 A1A1 A1 A1 A1A1 A1A1 A1A1 A1A1 A1A1 A1A1 A1 2'-8" 6'-0" 4'-8" 2'-8" 6'-0" ELEVATION NORTH PRIMARY GRANITE HORIZONTAL BANDING SCHED. GLAZING SCHEDULED MASONRY SILL APPROXIMATE GRADE FOUNDATION & FOOTINGS BEYOND, REF. STRUCTURAL TB ROOF ACCESS HATCH BEYOND A2 A2 SECONDARY ROOF DRAIN, REF. PLUMBING DRAWINGS SECONDARY ROOF DRAIN, REF. PLUMBING DRAWINGS SECONDARY ROOF DRAIN, REF. PLUMBING DRAWINGS 9.2 SKYLIGHT BEYOND C.J. 4 A3.41 C.J.C.J.C.J.C.J.C.J.C.J.C.J. SOLAR PANELS, BY OTHERS, BEYOND LEVEL 1 100' -0" LEVEL 2 113' -4" ROOF FRAMING 126' -8" GRANITE HORIZONTAL BANDING SCHED. GLAZING SPANDREL PANEL GLAZING SCHEDULED MASONRY SILL EDCBA B2 B1 B1.1 B3 B1 B1 B1 B2 PACKAGED ROOF TOP UNIT, REFERENCE MECHANICAL DRAWINGS, TYPICAL 19'-4" M.O. 2'-8" 117A EXT. SLAB, REF. STRUCTURAL APPROXIMATE GRADE FOUNDATION & FOOTINGS BEYOND, REF. STRUCTURAL C.J.C.J.C.J. C.J. SOLAR PANELS, BY OWNER COORD. LIGHT FIXTURE NORTH -PRIMARY NORTH -SECONDARY WEST EXISTING BUILDING NUMBER SIGNAGE W/ 18" ALUMINUM LETTERING W/ STAND OFFS LEVEL 1 100' -0" LEVEL 2 113' -4" ROOF FRAMING 126' -8" A A3.01 A A3.01 1 2 3 4 5 A1 A1 A1 A1 A1 A1 A1 A1 A1A1A1A1A1A1A1A1 PORTE COCHERE GRANITE HORIZONTAL BANDING SCHED. GLAZING SCHEDULED MASONRY SILL APPROXIMATE GRADE FOUNDATION & FOOTINGS BEYOND, REF. STRUCTURAL PACKAGED ROOF TOP UNIT, REFERENCE MECHANICAL DRAWINGS, TYPICAL M.O. 6'-0" 2'-8" 4'-8" M.O. 6'-0" 2'-8" ELEVATION SOUTH SECONDARY A2 A2 C.J.C.J.C.J.C.J. SOLAR PANELS, BY OWNER 5 A3.20 SIM ZINC RICH PRIMER PAINTED EXPOSED COLUMNS LEVEL 1 100' -0" LEVEL 2 113' -4" ROOF FRAMING 126' -8" B A3.01 B A3.01 C A3.01 C A3.01 16 1514131211 10 109 3 A4.03 3 A4.03 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1A1A1A1A1A1A1A1A1A1A1A1 101A PACKAGED ROOF TOP UNIT, REFERENCE MECHANICAL DRAWINGS, TYPICALPACKAGED ROOF TOP UNIT, REFERENCE MECHANICAL DRAWINGS, TYPICAL M.O. 6'-0" 2'-8" 4'-8" M.O. 6'-0" 2'-8" GRANITE HORIZONTAL BANDING SCHED. GLAZING SCHEDULED MASONRY SILL APPROXIMATE GRADE FOUNDATION & FOOTINGS BEYOND, REF. STRUCTURAL PORTE COCHERE ELEVATION SOUTH PRIMARY A2 A2 9.2 SKYLIGHT BEYOND C.J.C.J.C.J.C.J.C.J.C.J. SOLAR PANELS, BY OWNER 5 A3.20 SIM SOUTH PRIMARY SOUTH -SECONDARY NON-ILLUMINATED PLATE LETTERS NOTE: VINYL ON GLASS. STAFF ENTRANCE @ (BUILDING ADDTION NOT SHOWN) X X X s Primary Identity - Horizontal Letterset (One Color) 11'-0 3/4” 26'-0 5/8” 1' - 0 " 7 3 / 8 " 2' - 3 9 / 1 6 " PL12-N Non-Illuminated Plate Letters - Horizontal Layout (59.8 Sq Ft) Scale: 1/4” = 1’ - 0”