HomeMy WebLinkAboutZP-24-202 - 0255 Fairway Drive 7/19/2024CITY OF SOUTH BURLINGTON
ZONING PERMIT APPLICATION
PROPERTY Street Address: 255 Fairway Drive Application No:
office use only]
Property Owner: Zandy Wheeler/Karen George Parcel Size:
Property Owner Mailing Address:255 Fairway Drive S. Burlington, VT 05403
APPLICANT: Anna Thelemarck
Applicant Mailing Address: 343 North Street Burlington, VT 05401
Applicant Email: anna@strukturvt.com Daytime phone: 802-922-2632
1. PROPOSED project including building dimensions(describe):
We would like to build a 1 story,13'Wx14'D Sunroom addition o f of the existing dining room.
1a: IF NEW STRUCTURE
12,-8"Building height(see Land Development Regulations Definition of Height): ft.
of Bedrooms: 0
The project will comply with the City of South Burlington "Regulation of Heating and Service Water Heating Systems
in New Buildings"ordinance: EYes EINo
2. RELATED Site Plan,Conditional Use, PUD,Subdivision,or Misc Approval Number(if applicable)
3. Present USE(S)of the property:
0 Single family home on its own parcel
Other(please state the USE per Land Development Regulations-retail,general office, multifamily residential,etc.):
4. List all present structure(s)on property(describe including dimensions or square footage of each):
5. Does the project include a proposed change of USE?
oNo(the property will still be used for the same purpose)
DYes
a. proposed changed or added USES per Land Development Regulations-retail,general office, multifamily
residential, etc.):
b. proposed wastewater generation (GPD):
c. proposed PM Peak hour trip generation for entire property(in and out):
i. Land Use Code(s) Used,independent variables,calculations:
6. ESTIMATED total cost of improvements(materials and labor): $145,000.00
Complete the following only if the project involves changes to the dimensions of your building or other site changes(ie, not interior
renovations or roof/window/deck replacement)
7. BUILDING footprint—i.e.size in sq.ft. of main floor of house and all attached and detached structures including enclosed
breezeways,garages,and sheds(describe): Existing:Proposed:
8. TOTAL impervious surfaces on site(i.e. Building footprint PLUS size in s.f.of driveways, patios, decks):
Existing: Proposed:
Rev 2019-11
9. ATTACH SKETCH PLAN OR SITE PLAN
10. APPLICANT/OWNER CERTIFICATION
The undersigned property owner hereby consents to submission of this application and understands that if the application is
approved,L e Zoning Permit and any attached conditions will be binding on the property.
Prop rty Owner Signature
J
PRINT NAME Date
The undersigned applicant hereby affirms that the information presented in this application is true, accurate and complete.
2-LfAppscantSignaturePRINTNAMEDate
OFFICE USE ONLY-ADMINISTRATIVE OFFICER ACTION—OFFICE USE ONLY
DATE Received: 62 \2C) t_/FEE Received:$ 173 Identification of zoning district:
Project description:
SITE PLAN
Application# Approval Date
SUBDIVISION
Application# Approval Date
CONDITIONAL USE
Application# Approval Date
VARIANCE
Application# Approval Date
MISCELLANEOUS
Application# Approval Date
FINAL ADMINISTRATIVE OFFICER ACTION
ZONING PERMIT
APPROVED
Approval Date Administrative Officer's Signature
Permit EFFECTIVE date Permit EXPIRATION date
CONDITIONS of Approval
Provided applicant copy of URBEC or VCBE Standards Handbook or Not Applicable
I I DENIED
Denial Date Administrative Officer's Signature
REASON for DENIAL
Notice of Appeal Rights: Any interested person may appeal this decision by filing a written Notice of Appeal with the clerk of the Development Review
Board within fifteen[15]days of the date of this decision. The notice of appeal must be accompanied by a filing fee of$223.00.
This permit does NOT authorize commencement of any development activity approved by the permit until the permit takes effect as set forth
above. Site modifications and improvements made prior to this permit becoming effective may be subject to removal and site restoration if a timely
appeal is commenced.
NOTE:The applicant or permittee retains the obligation to identify,apply for,and obtain relevant state permits for this project.Call(802)477-2241 to
speak with the regional Permit Specialist.
Rev 2019-11
SEQ-NR
construction of one-story, 13' x 14' addition to rear of existing house
7/19/2024
8/4/2024 7/18/2025
X
X
addition must be set back at least 23.16 feet from rear property line
PROPOSED SETBACK
EXISTING SETBACK
u
S
RELOCATE
fir—
r
TRE S _ —_ 1,- r- t o
COORD.I ttCATIONW1* c
OWN
LEVEL
ENTRY HALL41:10LAWNBY
EXPAND IPROVING
CURVED PATIO WITH kill
STONE RELOCATED
RETAINING FROM NEW
cn
aI
FIELD SUNROOM
L J
VERIFY FOOTPRINT. — - i + n r
LAYOUT W/ I r LOWNERSs , +'. s z ""4x
I
fir m ¢
s ! ,> ` fir
r "';{h r „S v,ct'",+s a,yi i . KITCHEN
l..,,,,,t.i.-',:,,,.:':',!',:v,";.',,--,i,,1",;.*:8?,-'eg:,,-7:.. ,',.‘'.•,:,-....'-'
i k
a£ Y 4' ''' ' R kk1l N d a
I, i I
RI J
PORCH PLANTINGS V G
t*
LEVEL 1 SITE GO Off' %
401 O OSCALE: 1/4"=1'-0" 4
PORCH ADDITION
SITE PLAN WHEELER/GEORGE
1 /8"=1 '-O" S.BURLINGTON, VT A6
i
4.23.24
AiiiromMormW
SEPARATE/SEAL -----
AFTER SPACESATTICWWITHSHEATHING
UNVENTED ROOF VENTED ROOF
Li_1 '
I U'
i' 1 t
36x48 SKYLIGHT — y i I
NEW ASPHALT ROOFING 1 1• It_ILi I .'1 1_1.l' 1 tt..111i 11 I
TO MATCH EXG
ROOF EAVE/OVERHANG
DETAIL TO MATCH EXG.
1
NEW WINDOW HEAD HGT
90". FIELD COORDINATE W/
EXG SOFFIT RAKE HGT. It LI I 1 4i 1 L il 1\ Lill 1 ' it i I ',Li_1 11 i '
WINDOW GLASS TO BE 18" 1 1 IT I\., U 'I • 1, 1 , Lil 'LI1_ ` , Aa I1 LI '-. 'I11tlILit
MIN.A.F.F iJ _- _ . 1 III 1
11SETPOST/DETAIL 1 IT
U
I I 11 \L 'I-1j11_II 1 III LI i L I
1 :11L' _ all 1 illTRIML
is ..._
PROUD o 1 L 11 ,l,L,,.,1 a at ' l t Ll._1 ,- J L' 1_ II 1 lLilt! _ 1 I 1.111
PANEL/WINDOWS BY a"J I It 1
Ill 11 1_ '11 U
1
i\ L- c-_ 1 IL1 11 !k
1
NEW WINDOW SILL L LI l .l Ij l
1I, LJ\
1
Lid ILEL 1 _LI, lJ ,' I, ! ,lytl1. l_ _
J,L ! 1 1 [Htt 1t,t I t'-1 1
4. 1l l- t. I .1 t, Hit_t I ,l I , 1 H 1 l__tl I111 11 I liIIII I_I
1
11 • 1U) al! L'1' 11..I.I1 1 I' ' I l ILt_ll.-L;II. l',. —
i l: l INEWFLOORELEV._ t
1•
i l r
TO MATCH EXG1 I E+J
Li 1 i I 1 1. 1'11.la1
k::::':::'.L' ::'''' '...''..--- a
1x8 COMPOSITE TRIM,ALIGN i NEW ENCLO D SUNROOM INFILL NEW EXTERIOR WALLTO
J WITH POST ABOVE,AS SHOWN. /11: MATCH EXG SIDING AND TRIM
COMPRESSOR FOR HEAT PUMP.
i7 A\1x4 VERT, PICKET SCREEN W/2" i
COMPOSITE PANEL W/1x4
ALL BUILDING
SPACING. SEE SECTION 1/A5 K\ CONNECTIONS/LINES TO BE IN
FOR DETAILS h FRAME, CHAMFERED, OVER " WALLS AND NOT EXPOSED GO O CI
COMPOSITE SHEATHING.
4 WINDOWS BASED ON Q
NEW ADDITION ON(4) u\ SPAC EB AS SHOWN. O GO
GOLIATHTECH SCREWPILES L. MARVIN ELEVATE LDH3472 E
AND TIED TO EXG FOUNDATION ii, II'
n, it,
ELEVATION PORCH ADDITION
0 ELEVATIONS
fin_1 i_O
WHEELER/GEORGE
SCALE: 1/4"=1'-0" S.BURLINGTON, VT 3
4 I
4.23.24
EXISTING LIVING ROOM I
I I EXISTING DINING ROOM
II
ASSESS LOCATION OF—r 1 DEMO. DECK AND WALLS
STRUCTURAL SUPPORT L
AS SHOWN. COORDINATE
PRIOR TO WALL/WINDOW f' tea- SALVAGE/REUSE OF
REMOVAL Lr i I. WINDOW/DOOR/LIGHT r CONFIRM EXISTING CONC.WALL
T.
FIXTURE/COLUMN/CONDITION BELOW PORCHGUTTERWITHOWNERS.
EXISTING BACK PORCH SALVAGE STAIRS FOR
s
POSSIBLE REUSE AT NEW I I
LA ry SUNROOM EXIT I
1 h'r
I I L 1 + I
BEAM/CEILING/ROOF 4 a , COORD. GAS/ELECTRICAL
FRAMING TO BE OPENED I y ,,
v v,, , y,,, ,-, I CONNECTIONS FOR FUTURE GAS
IREMOVE/RELOCATE UP TO INSULATE/TIE INTO I yy,, Ci s. 4µ. i I STOVE
STONE PA-IO FOR REUSE PROPOSED PLAN. f 1 ' # 0f `
4,' 7 ",' ,
v•"
Ve I
7 o WORK.
COORDINATE WITH NEW I 1 r 4 ,, -s ,`rr,, , ' r I
p I r`
443, 4 It ,
Q o ( I
4'
j
f ,
COORD. FINAL SCREWPILE
4' of1 , s ,
S. fit, y LOCATIONS WITH BUILDING
COORDINATE SITE M c ., . ;h' fir'
ACCESS/PROTECTION/WORK
I
I .1 SECTIONS AND SCREWPILE
HOURS WITH
I I x ,„/, ' .) ENGINEER. REVIEW FINAL
OWNERS/ASSOCIATION I I )'k P tt '4,y ,
v,<'n' LOCATIONS W/ARCHITECT
REGULATIONS I; I
t PRIOR TO INSTALL
I fir ,''' rs T—6-12"CRUSHED STONE ON
COORDINATE TEMP. I I ,Ziit,ji J , MIRIFI FABRIC. EXTEND 6"
RELOCATION OF I - X ' ` , F i er OUTSIDE OF BUILDING
PLANTINGS WITH OWNERS I N c t l,f FOOTPRINT, 3 SIDES
w 2" 12'-0"
ADDITION
6" 6"
O
GO C' cO DEMOLITION PLAN FOUNDATION PLAN o O20SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0"
PORCH ADDITION
PLANS WHEELER/GEORGE
1„_1 Al011S.BURLINGTON, VT
A
4
4.23.24
ILI
O w 0 CO
Fizz
IxI- 20v031:1Clm re en LLJ
2coWW
LI
Z H z wOsQm HEAT PUMP MTD ON UPPER WALL.
6'-10" LINE OF EXG PROVIDE POWER AS NEEDED.ALL LINES
CONFIRM WITH OWNER IN FIELD a- EXTERIOR CONCEALED.NO EXPOSED WIRES/LINES
MATCH POST i 1 CORNER
TO EXG 2 1 iw a INSIDE INSIDE COORDINATE POWER FOR
e I II COMPRESSOR1A6A6I
o 4 BOOKSHELF BOOKSHELF r>
0
lc') I et i_\\
t,
I 1
1" 10 ig -l vI LINE OF EXG 01
EXTERIOR i
Zw c,, PORCH
I
r
Q j ¢ e7IN FOUNDATION 1 1 1
LL'• — > > cq 0 0 1
W0 t [II
0 p 7 PERIMETER LED CROWN
z a W w N re COORD. `II n`° MOLDING FIXTURES,3 SIDES
Q OO H w a EXTERIOR SITE u i - jioaN ILaVZOzF04DLIGHTINGW/ rW3V > iacc 1OWNER
Now LLO J „2wo oii 6wNSUNROOcu_ a ca
re z 1
o w 0 11=
WINDOW/ g z w rN 3
DOOR Ei
Li-O Q w = w CLNG FAN
w iv a 0 WITH REMOVE CONTROL.
O w COORD. LOCATION W/
1 L z o w
IC=i \
1 X OWNER Inc=I
A5 cc MARVIN c F- i ,,N A5 V w
ELEVATE A 00 re
PICTURE WINDOW w I N ii N
6072 w
W
F;!: El': IK.: _ Z I,;2q dIIj NOTES:
1. PROVIDE A WALK THROUGH WITH OWNERSMARVIN2 ,r _ 1 MARVIN p I PRIOR TO RUNNING ELECTRICALELEVATEA6A6ELEVATEre
0 LIGHTING/SWITCHED TO REVIEW PLANSELDH3472EELDH3472E02. PROVIDE DIMMERS AT ALL NEW LIGHTING
I CONFIRMDOW P FINALN 3. LOCATE INTERNET/TV CONNECTION WITH
OWNERS
4. ELECTRICIAN TO COMPLY WITH ALL
LOCAL/STATE CODES.THESE DRAWINGS ARE
12'-11%2"INTENDED TO SHOW MIN.CH
FIELD VERIFY LOCATIONS AS DESIRED BY OWNERS
O
410FLOOR PLAN ELECTRICAL PLAN
NN
O OG `
SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0"
o
PORCH ADDITION
PLANS WHEELER/GEORGE
1„_1 ,_o„ S.BURLINGTON, VT A2
4
5.17.24
NEW ASPHALT ROOFING
TO MATCH EXG
ROOF EAVE/OVERHANG
DETAIL TO MATCH EXG.
NEW WINDOW HEAD HGT
NEW DOOR I 90".FIELD COORDINATE W/
HEAD HGT @ 86".I EXG SOFFIT HGT AND SILL(
I TO BE 18"MIN.A.F.F)MARVIN MARVIN MARVIN
I ELEVATE ELEVATE ELEVATE
I LDH3472 E PICTURE LDH3472 E
ELDVPF872
ARVIN ELATE FRENC-I
SLIDER ELS=D10070
NEW FLOOR ELEV. NEW FLOOR ELEV.
TO MATCH EXG I TO MATCH EXG
7-
x H.
O
u u u u 4 GII' ii a
J - `w•n, n, n, n, 5
1
ELEVATION ELEVATION O OG
SCALE: 1/4"=1'-0" 2 SCALE: 1/4"=1'-0" O GOB`
PORCH ADDITION
ELEVATIONS WHEELER/GEORGE-
S.BURLINGTON, VT A4
4 1 -
5.17.24
SLUFL I U iVhk-I-Ui -
ROOF BEYOND O1UNVENTEDROOFASSEMBLYATNEWADDITION. VENTED ROOF AT
EXISTING. PROVIDE VERTICAL SEPARATION BETWEEN THE TWO 0 <2
SYSTEMS. w V+ 1'UNVENTED ROOF ASSEMBLY: — OVERHANG AND TRIM
z" GWB, FINISHED, PRIMED, PTD DETAIL TO MATCH EXISTING O 0 Cl2x12RAFTERSAT16"O.C. O3'CLOSED CELL SPRAYFOAM (R-53), RETURN TO CD QWALLPLATES1\
O z GO
5/8"ADVANTECH SHEATHING I XUNDERLAYMENT. w w
ASPHALT ROOFING o I
EQ
T O.WINDOWS @ 7'-6"(V.I.F.)NEW
SUNROOM WHITE 4" METAL GUTTERS, 2 SIDES.
WALL ASSEMBLY: - OUTLET TBD W/OWNERS
4"GWB, PRIMED/PTD FLOOR ASSEMBLY:
CLEAR VERTICAL SHIPLAP-NICKEL GAP PREFINISHED WOOD FLOORING TO BURY HEAT PUMP LINES DURING w
SPACING-BELOW WINDOWS-FINISH TBD MATCH EXISTING CONSTRUCTION. NO EXPOSED LINES 0
2x6 WD FRAMING @ 16"O.C. 3/4"T AND G ADVANTECH SUBFLOOR rt o -
4" MIN. (R-30)CLOSED CELL SPRAY FOAM 2x10 FLOOR FRAMING, SET IN LINE WITH CAULK/AIR SEAL ALL EXTERIOR O Z
INSULATION 2x4 FLOOR FRAME OaFLOOR/WALL/ROOF SHEATHING TO FRAMING. LL > 0
1/2" PLYWOOD SHEATHING 2x4 SUBFLOOR FRAME WINDOW/DOOR OPENING GAPS SEALED W/ 1- opQ
BENJAMIN OBDYKE CLASSIC SLICKER R-384" 5.5" CLOSED CELL SPRAY FOAM EXPANDING FOAM. w w z
4 O ao
RAINSCREEN INFILL IN 2x4+ FLOOR SYSTEM, AS SHOWN O 0 z w
CEDAR SHAKES, PRIMED ALL SIDES, 1/2"CONTINUOUS RIGID INSULATION, w ¢ w °°
PAINTED TAPED Ii cc) o SS
O
1/2" P.T SHEATHING 7 T.'--
P.T BEAM SET ON o U u)I--
POSTECH SADDLESRETURNCLOSEDCELLZ0w S 2 d
SPRAYFOAM FOR FULL DEPTH TO o LI _ Z O 0
SIDEWALL ASSEMBLY AT M Oz OZ _I O L GALV. MTL WIRE MESH. MAX.2"SQ.
FLOOR/CEILING TRANSITIONS OM
MI1 U z_
r _ _
CONNECT W/P.T ANCHOR AND
BURY IN STONE
I I ALIGN FLOOR W/EXG
I
COMPRESSOR LOCATION.
CD 1 I SEE ELEVATION
CLEANED AND REINSTALLED. PREP L. icy
EXG PAVERS TO BE REMOVED, -
SUBSURFACE AS NEEDED FOR N — i rN I
i GARDEN BED.COORD.W/OWNER
PROPER INSTALLATION I A J
1 I LAWN. SLOPE AWAY FROM BLDG
y.L'IJf, _ 2 ..J %yZj.'f' )
r,.(e):
J S' /1 P ` Y 1!`
I. d..Gc,.
6-12"CRUSHED STONE ON MIRIFI
FABRIC. EXTEND 6"OUTSIDE OFSEEDETAILX/XX SECTION 6"TYP. ``` , : BUILDING FOOTPRINT, 3 SIDES
SCALE: 1/2"=1'-0" GOLIATHTECH SCREWPILE.
INSTALLATION TO MEET REQ'D
STRUCTURAL CODES
PORCH ADDITION
SECTIONS WHEELER/GEORGE
1 /2"=1 '-0" S.BURLINGTON, VT A5
4.23.24