Loading...
HomeMy WebLinkAboutZP-24-202 - 0255 Fairway Drive 7/19/2024CITY OF SOUTH BURLINGTON ZONING PERMIT APPLICATION PROPERTY Street Address: 255 Fairway Drive Application No: office use only] Property Owner: Zandy Wheeler/Karen George Parcel Size: Property Owner Mailing Address:255 Fairway Drive S. Burlington, VT 05403 APPLICANT: Anna Thelemarck Applicant Mailing Address: 343 North Street Burlington, VT 05401 Applicant Email: anna@strukturvt.com Daytime phone: 802-922-2632 1. PROPOSED project including building dimensions(describe): We would like to build a 1 story,13'Wx14'D Sunroom addition o f of the existing dining room. 1a: IF NEW STRUCTURE 12,-8"Building height(see Land Development Regulations Definition of Height): ft. of Bedrooms: 0 The project will comply with the City of South Burlington "Regulation of Heating and Service Water Heating Systems in New Buildings"ordinance: EYes EINo 2. RELATED Site Plan,Conditional Use, PUD,Subdivision,or Misc Approval Number(if applicable) 3. Present USE(S)of the property: 0 Single family home on its own parcel Other(please state the USE per Land Development Regulations-retail,general office, multifamily residential,etc.): 4. List all present structure(s)on property(describe including dimensions or square footage of each): 5. Does the project include a proposed change of USE? oNo(the property will still be used for the same purpose) DYes a. proposed changed or added USES per Land Development Regulations-retail,general office, multifamily residential, etc.): b. proposed wastewater generation (GPD): c. proposed PM Peak hour trip generation for entire property(in and out): i. Land Use Code(s) Used,independent variables,calculations: 6. ESTIMATED total cost of improvements(materials and labor): $145,000.00 Complete the following only if the project involves changes to the dimensions of your building or other site changes(ie, not interior renovations or roof/window/deck replacement) 7. BUILDING footprint—i.e.size in sq.ft. of main floor of house and all attached and detached structures including enclosed breezeways,garages,and sheds(describe): Existing:Proposed: 8. TOTAL impervious surfaces on site(i.e. Building footprint PLUS size in s.f.of driveways, patios, decks): Existing: Proposed: Rev 2019-11 9. ATTACH SKETCH PLAN OR SITE PLAN 10. APPLICANT/OWNER CERTIFICATION The undersigned property owner hereby consents to submission of this application and understands that if the application is approved,L e Zoning Permit and any attached conditions will be binding on the property. Prop rty Owner Signature J PRINT NAME Date The undersigned applicant hereby affirms that the information presented in this application is true, accurate and complete. 2-LfAppscantSignaturePRINTNAMEDate OFFICE USE ONLY-ADMINISTRATIVE OFFICER ACTION—OFFICE USE ONLY DATE Received: 62 \2C) t_/FEE Received:$ 173 Identification of zoning district: Project description: SITE PLAN Application# Approval Date SUBDIVISION Application# Approval Date CONDITIONAL USE Application# Approval Date VARIANCE Application# Approval Date MISCELLANEOUS Application# Approval Date FINAL ADMINISTRATIVE OFFICER ACTION ZONING PERMIT APPROVED Approval Date Administrative Officer's Signature Permit EFFECTIVE date Permit EXPIRATION date CONDITIONS of Approval Provided applicant copy of URBEC or VCBE Standards Handbook or Not Applicable I I DENIED Denial Date Administrative Officer's Signature REASON for DENIAL Notice of Appeal Rights: Any interested person may appeal this decision by filing a written Notice of Appeal with the clerk of the Development Review Board within fifteen[15]days of the date of this decision. The notice of appeal must be accompanied by a filing fee of$223.00. This permit does NOT authorize commencement of any development activity approved by the permit until the permit takes effect as set forth above. Site modifications and improvements made prior to this permit becoming effective may be subject to removal and site restoration if a timely appeal is commenced. NOTE:The applicant or permittee retains the obligation to identify,apply for,and obtain relevant state permits for this project.Call(802)477-2241 to speak with the regional Permit Specialist. Rev 2019-11 SEQ-NR construction of one-story, 13' x 14' addition to rear of existing house 7/19/2024 8/4/2024 7/18/2025 X X addition must be set back at least 23.16 feet from rear property line PROPOSED SETBACK EXISTING SETBACK u S RELOCATE fir— r TRE S _ —_ 1,- r- t o COORD.I ttCATIONW1* c OWN LEVEL ENTRY HALL41:10LAWNBY EXPAND IPROVING CURVED PATIO WITH kill STONE RELOCATED RETAINING FROM NEW cn aI FIELD SUNROOM L J VERIFY FOOTPRINT. — - i + n r LAYOUT W/ I r LOWNERSs , +'. s z ""4x I fir m ¢ s ! ,> ` fir r "';{h r „S v,ct'",+s a,yi i . KITCHEN l..,,,,,t.i.-',:,,,.:':',!',:v,";.',,--,i,,1",;.*:8?,-'eg:,,-7:.. ,',.‘'.•,:,-....'-' i k a£ Y 4' ''' ' R kk1l N d a I, i I RI J PORCH PLANTINGS V G t* LEVEL 1 SITE GO Off' % 401 O OSCALE: 1/4"=1'-0" 4 PORCH ADDITION SITE PLAN WHEELER/GEORGE 1 /8"=1 '-O" S.BURLINGTON, VT A6 i 4.23.24 AiiiromMormW SEPARATE/SEAL ----- AFTER SPACESATTICWWITHSHEATHING UNVENTED ROOF VENTED ROOF Li_1 ' I U' i' 1 t 36x48 SKYLIGHT — y i I NEW ASPHALT ROOFING 1 1• It_ILi I .'1 1_1.l' 1 tt..111i 11 I TO MATCH EXG ROOF EAVE/OVERHANG DETAIL TO MATCH EXG. 1 NEW WINDOW HEAD HGT 90". FIELD COORDINATE W/ EXG SOFFIT RAKE HGT. It LI I 1 4i 1 L il 1\ Lill 1 ' it i I ',Li_1 11 i ' WINDOW GLASS TO BE 18" 1 1 IT I\., U 'I • 1, 1 , Lil 'LI1_ ` , Aa I1 LI '-. 'I11tlILit MIN.A.F.F iJ _- _ . 1 III 1 11SETPOST/DETAIL 1 IT U I I 11 \L 'I-1j11_II 1 III LI i L I 1 :11L' _ all 1 illTRIML is ..._ PROUD o 1 L 11 ,l,L,,.,1 a at ' l t Ll._1 ,- J L' 1_ II 1 lLilt! _ 1 I 1.111 PANEL/WINDOWS BY a"J I It 1 Ill 11 1_ '11 U 1 i\ L- c-_ 1 IL1 11 !k 1 NEW WINDOW SILL L LI l .l Ij l 1I, LJ\ 1 Lid ILEL 1 _LI, lJ ,' I, ! ,lytl1. l_ _ J,L ! 1 1 [Htt 1t,t I t'-1 1 4. 1l l- t. I .1 t, Hit_t I ,l I , 1 H 1 l__tl I111 11 I liIIII I_I 1 11 • 1U) al! L'1' 11..I.I1 1 I' ' I l ILt_ll.-L;II. l',. — i l: l INEWFLOORELEV._ t 1• i l r TO MATCH EXG1 I E+J Li 1 i I 1 1. 1'11.la1 k::::':::'.L' ::'''' '...''..--- a 1x8 COMPOSITE TRIM,ALIGN i NEW ENCLO D SUNROOM INFILL NEW EXTERIOR WALLTO J WITH POST ABOVE,AS SHOWN. /11: MATCH EXG SIDING AND TRIM COMPRESSOR FOR HEAT PUMP. i7 A\1x4 VERT, PICKET SCREEN W/2" i COMPOSITE PANEL W/1x4 ALL BUILDING SPACING. SEE SECTION 1/A5 K\ CONNECTIONS/LINES TO BE IN FOR DETAILS h FRAME, CHAMFERED, OVER " WALLS AND NOT EXPOSED GO O CI COMPOSITE SHEATHING. 4 WINDOWS BASED ON Q NEW ADDITION ON(4) u\ SPAC EB AS SHOWN. O GO GOLIATHTECH SCREWPILES L. MARVIN ELEVATE LDH3472 E AND TIED TO EXG FOUNDATION ii, II' n, it, ELEVATION PORCH ADDITION 0 ELEVATIONS fin_1 i_O WHEELER/GEORGE SCALE: 1/4"=1'-0" S.BURLINGTON, VT 3 4 I 4.23.24 EXISTING LIVING ROOM I I I EXISTING DINING ROOM II ASSESS LOCATION OF—r 1 DEMO. DECK AND WALLS STRUCTURAL SUPPORT L AS SHOWN. COORDINATE PRIOR TO WALL/WINDOW f' tea- SALVAGE/REUSE OF REMOVAL Lr i I. WINDOW/DOOR/LIGHT r CONFIRM EXISTING CONC.WALL T. FIXTURE/COLUMN/CONDITION BELOW PORCHGUTTERWITHOWNERS. EXISTING BACK PORCH SALVAGE STAIRS FOR s POSSIBLE REUSE AT NEW I I LA ry SUNROOM EXIT I 1 h'r I I L 1 + I BEAM/CEILING/ROOF 4 a , COORD. GAS/ELECTRICAL FRAMING TO BE OPENED I y ,, v v,, , y,,, ,-, I CONNECTIONS FOR FUTURE GAS IREMOVE/RELOCATE UP TO INSULATE/TIE INTO I yy,, Ci s. 4µ. i I STOVE STONE PA-IO FOR REUSE PROPOSED PLAN. f 1 ' # 0f ` 4,' 7 ",' , v•" Ve I 7 o WORK. COORDINATE WITH NEW I 1 r 4 ,, -s ,`rr,, , ' r I p I r` 443, 4 It , Q o ( I 4' j f , COORD. FINAL SCREWPILE 4' of1 , s , S. fit, y LOCATIONS WITH BUILDING COORDINATE SITE M c ., . ;h' fir' ACCESS/PROTECTION/WORK I I .1 SECTIONS AND SCREWPILE HOURS WITH I I x ,„/, ' .) ENGINEER. REVIEW FINAL OWNERS/ASSOCIATION I I )'k P tt '4,y , v,<'n' LOCATIONS W/ARCHITECT REGULATIONS I; I t PRIOR TO INSTALL I fir ,''' rs T—6-12"CRUSHED STONE ON COORDINATE TEMP. I I ,Ziit,ji J , MIRIFI FABRIC. EXTEND 6" RELOCATION OF I - X ' ` , F i er OUTSIDE OF BUILDING PLANTINGS WITH OWNERS I N c t l,f FOOTPRINT, 3 SIDES w 2" 12'-0" ADDITION 6" 6" O GO C' cO DEMOLITION PLAN FOUNDATION PLAN o O20SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" PORCH ADDITION PLANS WHEELER/GEORGE 1„_1 Al011S.BURLINGTON, VT A 4 4.23.24 ILI O w 0 CO Fizz IxI- 20v031:1Clm re en LLJ 2coWW LI Z H z wOsQm HEAT PUMP MTD ON UPPER WALL. 6'-10" LINE OF EXG PROVIDE POWER AS NEEDED.ALL LINES CONFIRM WITH OWNER IN FIELD a- EXTERIOR CONCEALED.NO EXPOSED WIRES/LINES MATCH POST i 1 CORNER TO EXG 2 1 iw a INSIDE INSIDE COORDINATE POWER FOR e I II COMPRESSOR1A6A6I o 4 BOOKSHELF BOOKSHELF r> 0 lc') I et i_\\ t, I 1 1" 10 ig -l vI LINE OF EXG 01 EXTERIOR i Zw c,, PORCH I r Q j ¢ e7IN FOUNDATION 1 1 1 LL'• — > > cq 0 0 1 W0 t [II 0 p 7 PERIMETER LED CROWN z a W w N re COORD. `II n`° MOLDING FIXTURES,3 SIDES Q OO H w a EXTERIOR SITE u i - jioaN ILaVZOzF04DLIGHTINGW/ rW3V > iacc 1OWNER Now LLO J „2wo oii 6wNSUNROOcu_ a ca re z 1 o w 0 11= WINDOW/ g z w rN 3 DOOR Ei Li-O Q w = w CLNG FAN w iv a 0 WITH REMOVE CONTROL. O w COORD. LOCATION W/ 1 L z o w IC=i \ 1 X OWNER Inc=I A5 cc MARVIN c F- i ,,N A5 V w ELEVATE A 00 re PICTURE WINDOW w I N ii N 6072 w W F;!: El': IK.: _ Z I,;2q dIIj NOTES: 1. PROVIDE A WALK THROUGH WITH OWNERSMARVIN2 ,r _ 1 MARVIN p I PRIOR TO RUNNING ELECTRICALELEVATEA6A6ELEVATEre 0 LIGHTING/SWITCHED TO REVIEW PLANSELDH3472EELDH3472E02. PROVIDE DIMMERS AT ALL NEW LIGHTING I CONFIRMDOW P FINALN 3. LOCATE INTERNET/TV CONNECTION WITH OWNERS 4. ELECTRICIAN TO COMPLY WITH ALL LOCAL/STATE CODES.THESE DRAWINGS ARE 12'-11%2"INTENDED TO SHOW MIN.CH FIELD VERIFY LOCATIONS AS DESIRED BY OWNERS O 410FLOOR PLAN ELECTRICAL PLAN NN O OG ` SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" o PORCH ADDITION PLANS WHEELER/GEORGE 1„_1 ,_o„ S.BURLINGTON, VT A2 4 5.17.24 NEW ASPHALT ROOFING TO MATCH EXG ROOF EAVE/OVERHANG DETAIL TO MATCH EXG. NEW WINDOW HEAD HGT NEW DOOR I 90".FIELD COORDINATE W/ HEAD HGT @ 86".I EXG SOFFIT HGT AND SILL( I TO BE 18"MIN.A.F.F)MARVIN MARVIN MARVIN I ELEVATE ELEVATE ELEVATE I LDH3472 E PICTURE LDH3472 E ELDVPF872 ARVIN ELATE FRENC-I SLIDER ELS=D10070 NEW FLOOR ELEV. NEW FLOOR ELEV. TO MATCH EXG I TO MATCH EXG 7- x H. O u u u u 4 GII' ii a J - `w•n, n, n, n, 5 1 ELEVATION ELEVATION O OG SCALE: 1/4"=1'-0" 2 SCALE: 1/4"=1'-0" O GOB` PORCH ADDITION ELEVATIONS WHEELER/GEORGE- S.BURLINGTON, VT A4 4 1 - 5.17.24 SLUFL I U iVhk-I-Ui - ROOF BEYOND O1UNVENTEDROOFASSEMBLYATNEWADDITION. VENTED ROOF AT EXISTING. PROVIDE VERTICAL SEPARATION BETWEEN THE TWO 0 <2 SYSTEMS. w V+ 1'UNVENTED ROOF ASSEMBLY: — OVERHANG AND TRIM z" GWB, FINISHED, PRIMED, PTD DETAIL TO MATCH EXISTING O 0 Cl2x12RAFTERSAT16"O.C. O3'CLOSED CELL SPRAYFOAM (R-53), RETURN TO CD QWALLPLATES1\ O z GO 5/8"ADVANTECH SHEATHING I XUNDERLAYMENT. w w ASPHALT ROOFING o I EQ T O.WINDOWS @ 7'-6"(V.I.F.)NEW SUNROOM WHITE 4" METAL GUTTERS, 2 SIDES. WALL ASSEMBLY: - OUTLET TBD W/OWNERS 4"GWB, PRIMED/PTD FLOOR ASSEMBLY: CLEAR VERTICAL SHIPLAP-NICKEL GAP PREFINISHED WOOD FLOORING TO BURY HEAT PUMP LINES DURING w SPACING-BELOW WINDOWS-FINISH TBD MATCH EXISTING CONSTRUCTION. NO EXPOSED LINES 0 2x6 WD FRAMING @ 16"O.C. 3/4"T AND G ADVANTECH SUBFLOOR rt o - 4" MIN. (R-30)CLOSED CELL SPRAY FOAM 2x10 FLOOR FRAMING, SET IN LINE WITH CAULK/AIR SEAL ALL EXTERIOR O Z INSULATION 2x4 FLOOR FRAME OaFLOOR/WALL/ROOF SHEATHING TO FRAMING. LL > 0 1/2" PLYWOOD SHEATHING 2x4 SUBFLOOR FRAME WINDOW/DOOR OPENING GAPS SEALED W/ 1- opQ BENJAMIN OBDYKE CLASSIC SLICKER R-384" 5.5" CLOSED CELL SPRAY FOAM EXPANDING FOAM. w w z 4 O ao RAINSCREEN INFILL IN 2x4+ FLOOR SYSTEM, AS SHOWN O 0 z w CEDAR SHAKES, PRIMED ALL SIDES, 1/2"CONTINUOUS RIGID INSULATION, w ¢ w °° PAINTED TAPED Ii cc) o SS O 1/2" P.T SHEATHING 7 T.'-- P.T BEAM SET ON o U u)I-- POSTECH SADDLESRETURNCLOSEDCELLZ0w S 2 d SPRAYFOAM FOR FULL DEPTH TO o LI _ Z O 0 SIDEWALL ASSEMBLY AT M Oz OZ _I O L GALV. MTL WIRE MESH. MAX.2"SQ. FLOOR/CEILING TRANSITIONS OM MI1 U z_ r _ _ CONNECT W/P.T ANCHOR AND BURY IN STONE I I ALIGN FLOOR W/EXG I COMPRESSOR LOCATION. CD 1 I SEE ELEVATION CLEANED AND REINSTALLED. PREP L. icy EXG PAVERS TO BE REMOVED, - SUBSURFACE AS NEEDED FOR N — i rN I i GARDEN BED.COORD.W/OWNER PROPER INSTALLATION I A J 1 I LAWN. SLOPE AWAY FROM BLDG y.L'IJf, _ 2 ..J %yZj.'f' ) r,.(e): J S' /1 P ` Y 1!` I. d..Gc,. 6-12"CRUSHED STONE ON MIRIFI FABRIC. EXTEND 6"OUTSIDE OFSEEDETAILX/XX SECTION 6"TYP. ``` , : BUILDING FOOTPRINT, 3 SIDES SCALE: 1/2"=1'-0" GOLIATHTECH SCREWPILE. INSTALLATION TO MEET REQ'D STRUCTURAL CODES PORCH ADDITION SECTIONS WHEELER/GEORGE 1 /2"=1 '-0" S.BURLINGTON, VT A5 4.23.24