HomeMy WebLinkAboutZP-24-220 - 0203 Leo Lane 7/18/2024ZP-24-220 07/02/2024 R1 PRD single family home 1,313.40 #SD-22-10A 01/19/2023 07/18/2024 08/03/2024 07/17/2025 (Acting) VIA HAND-DELIVERY June 20, 2024 Betsy Brown South Burlington Planning and Zoning 180 Market Street South Burlington, VT 05403 Re: Zoning Permit Application 203 Leo Lane, South Burlington, VT 05403 Betsy, Further to Final Plat Permit SD-22-10A, enclosed please find a zoning permit application for 203 Leo Lane, South Burlington, Vermont 05403, Unit 16-14 on the Final Plat/Site Plan submitted as part of SD-22-10A. Also enclosed please find: 1. A Water Allocation Application; 2. A Wastewater Allocation Application. 3. A wastewater Connection Application. 4. A site plan of the applicable area of the proposed home. 5. An architectural drawing showing compliance with plans proposed and permitted in SD- 22-10A. Regarding the height of the proposed structure, it is calculated per the approved methodology and is listed on the zoning permit application as such. Please contact us with any questions or concerns. Sincerely, Brandon Secl, Estimator Property Owners Name:O'Brien Eastview Property Location:203 Leo Lane Amount:15,712.85 Payment Type:check #2113 Date:7/2/2024 Code Zoning Permit (New Residential)ZP-24-220 zp Recording fee 13.00$ plus addition/alteration cost 5.00$ per $1,000 project cost -$ OR: plus 2216 0.45$ per sq. ft.997.20$ plus 1016 0.20$ per sq. ft.203.20$ plus 2 50.00$ per bay 100.00$ After-the fact of 50%[no NOV]or 100%[NOV]-$ Zoning Permit Total 1,313.40$ Sewer Allocation Fee WWA-24-136 #204 249.15 g.p.d x 16.17$ 4,028.76$ Bartlett Bay x Airport Parkway Impact Fee Administrative Fee #248 per application $100.00 School Impact Fee #222S 3 bedrooms 8,747.51$ Recreation Impact Fee*#220 /unit -$ South Village Recreation Impact Fee #243 /unit -$ Road Impact Fee #221 $963.73 /unit 963.73$ Fire Impact Fee #203 /unit -$ Police Impact Fee #222 $496.45 /unit 496.45$ Dorset Street Waterline Fee #230 /unit -$ Sewer Connection Inspection WWC-24-41 ww 63.00$ per connection 63.00$ *credit issued by City Council on 6/26/23 Total (Impact Fees + Permit)15,712.85$ Planning & Zoning Invoice Residential Impact & Permit Fees garage bay(s) at Amount Due sq. ft building at sq. ft unfinished basement at IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 6/ 1 3 / 2 0 2 4 1 1 : 4 2 : 0 9 A M C : \ U s e r s \ c h a r l o t t e \ O ' B r i e n B r o th e r s A g e n c y , I n c \ H o m e B u i l d i n g - N e i g h b o r h o o d s \ H i l ls i d e E a s t \ R e v i t P l a n s \ S F - 2 _ R 2 0 1 9 M i r r o r e d . r v t A0.000 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t COVER SHEET 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 Hillside at O'Brien Farm -Village Green Hilltop Single Family South Burlington, Vermont AREA SCHEDULE - STANDARD AREA NAME AREA ELEVATION A MAIN FLOOR LIVABLE 1171 SF UPPER FLOOR LIVABLE 1045 SF LIVABLE 2216 SF 2-CAR GARAGE 464 SF PORCH 119 SF DECK 143 SF UNFINISHED BASEMENT 1016 SF NON-LIVABLE 1742 SF ELEVATION A 3958 SF ELEVATION B MAIN FLOOR LIVABLE 1169 SF UPPER FLOOR LIVABLE 1045 SF LIVABLE 2214 SF 2-CAR GARAGE 467 SF PORCH 106 SF DECK 143 SF UNFINISHED BASEMENT 1016 SF NON-LIVABLE 1732 SF ELEVATION B 3946 SF AREA SCHEDULE - OPTIONS AREA NAME AREA OPT FINISHED BASEMENT FINISHED BASEMENT 754 SF UNFINISHED 231 SF TOTAL 984 SF Elevation A -Craftsman Elevation B -Farmhouse SHEET INDEX SHEET NUMBER SHEET NAME ARCHITECTURAL A0.000 COVER SHEET A0.001 ARCHITECTURAL GENERAL NOTES A1.100 BASEMENT FLOOR PLAN - ELEVATION A A1.110 MAIN FLOOR PLAN - ELEVATION A A1.120 UPPER FLOOR PLAN - ELEVATION A A1.200 EXTERIOR ELEVATIONS - ELEVATION A A1.201 EXTERIOR ELEVATIONS - ELEVATION A A1.300 ROOF PLAN - ELEVATION A A1.400 BUILDING SECTIONS - ELEVATION A A1.500 STAIR SECTION A1.600 FLOOR PLAN OPTIONS - ALL ELEVATIONS A1.700 OPT DAYLIGHT BASEMENT A1.701 OPT DAYLIGHT BASEMENT A2.100 BASEMENT FLOOR PLAN - ELEVATION B A2.110 MAIN FLOOR PLAN - ELEVATION B A2.120 UPPER FLOOR PLAN - ELEVATION B A2.200 EXTERIOR ELEVATIONS - ELEVATION B A2.201 EXTERIOR ELEVATIONS - ELEVATION B A2.300 ROOF PLAN - ELEVATION B A2.400 BUILDING SECTIONS - ELEVATION B AD.1 ARCHITECTURAL DETAILS AD.2 ARCHITECTURAL DETAILS AD.3 ARCHITECTURAL DETAILS ELECTRICAL E1.100 BASEMENT ELECTRICAL PLAN - ELEVATION A E1.110 MAIN FLOOR ELECTRICAL PLAN - ELEVATION A E1.120 UPPER FLOOR ELECTRICAL PLAN - ELEVATION A E1.600 FLOOR PLAN OPTION - ELECTRICAL PLANS E2.100 BASEMENT ELECTRICAL PLAN - ELEVATION B E2.110 MAIN FLOOR ELECTRICAL PLAN - ELEVATION B E2.120 UPPER FLOOR ELECTRICAL PLAN - ELEVATION B STRUCTURAL S-0.1 GENERAL NOTES S-0.2 GENERAL NOTES S-0.3 GENERAL NOTES S-0.4 TYPICAL DETAILS S-0.5 TYPICAL DETAILS S-0.6 TYPICAL DETAILS S-0.7 TYPICAL DETAILS S-0.8 TYPICAL DETAILS S-0.9 TYPICAL DETAILS S-0.10 TYPICAL DETAILS S-0.11 TYPICAL DETAILS S-0.12 TYPICAL DETAILS S-1.0 FOUNDATION ELEVATION A S-1.1 FOUNDATION ELEVATION B S-2.0 FRAMING ELEVATION A S-2.1 FRAMING ELEVATION A S-2.2 FRAMING ELEVATION B S-2.3 FRAMING ELEVATION B S-2.4 OPTIONAL BASEMENT PLANS ALL ELEVATIONS S-3.0 SHEARWALL ELEVATION A S-3.1 SHEARWALL ELEVATION A S-3.2 SHEARWALL ELEVATION A S-3.3 SHEARWALL ELEVATION B S-3.4 SHEARWALL ELEVATION B S-3.5 SHEARWALL ELEVATION B TOTAL NUMBER OF SHEETS: 55 UP 15 RISERS A-1 A1.400 45 ' - 0 " 2' - 0 " 6' - 0 " 40' - 0" 11' - 10"7' - 4"20' - 10" 10"8' - 4"1' - 4"8' - 4"2' - 0" 1' - 0 " 22 ' - 4 " UNEXCAVATED 1' - 0 " 7' - 0 " 21 ' - 0 " 10 " 9' - 8 1 / 2 " 001001 A-2 A1.400 21 ' - 8 " 37 ' - 0 " 45 ' - 0 " 18' - 0"22' - 0" 10 " 10" 10 " 10" 10" 10 " 1 A1.500 8' -9" CLG UNFINISHED BASEMENT AIR HANDLER 6' - 0"6' - 0" 8' -9" CLG STORAGEUNEXCAVATED 12 ' - 0 " 9' - 8"4' - 6"6' - 2"10" HR V 1' - 4 " 12' - 0" 10"17' - 2"1' - 4"5' - 0"3' - 5 1/2"11' - 4 1/2"10" 10"10' - 11"8 1/2"3' - 1"2' - 5 1/2"10" 8" 6 1 / 2 " 3' - 1 1 / 2 " 3' - 9 1 / 2 " 3050 DH(2) 3068 FR DR (TEMP)3050 DH 9' - 0"14' - 0"12' - 0"5' - 0" 17' - 0"11' - 0" 40' - 0" 12 ' - 0 " 17' - 2"5"5' - 10"3' - 6 1/2"4' - 4 1/2"7' - 0" 14 ' - 1 0 1 / 2 " 2x6 WALL 2x 6 W A L L 004 016 018 017 10 " 10 " 10" WH 30 6 8 4' - 4 1 / 2 " 22 ' - 1 " 010 16 RISERS AS REQUIRED IS S U E D A T E : RE V I S I O N S JOB NO: PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.100 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t BASEMENT FLOOR PLAN - ELEVATION A AREA SCHEDULE - STANDARD - ELEV A Area Key AREA NAME AREA ELEVATION A A MAIN FLOOR LIVABLE 1171 SF B UPPER FLOOR LIVABLE 1045 SF LIVABLE 2216 SF C 2-CAR GARAGE 464 SF E PORCH 119 SF D DECK 143 SF E UNFINISHED BASEMENT 1016 SF NON-LIVABLE 1742 SF ELEVATION A 3958 SF GENERAL FLOOR PLAN NOTES • MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) • WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. • PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. • ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. • PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. • SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. • PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. • ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) • ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) • CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. • ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. • ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. • FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. FLOOR PLAN KEYNOTES 001 DROP TOP OF FOUNDATION AT OVERHEAD GARAGE DOOR. 004 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS UNDER ACCESSIBLE ENCLOSED STAIRS. 010 HANDRAIL. 016 LINE OF DECKING ABOVE. 017 GYPSUM BOARD OPENING 7'-6" AT BASEMENT. 018 3" RIGID INSULATION. SCALE: 1/4" = 1'-0" Basement Plan -Elevation A CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. DN UP 16 RISERS DN 15 RISERS A-1 A1.400 1' - 8"4' - 0"1' - 8"5' - 0"9' - 8"6' - 2" 6' - 1 " 2' - 0 " 6' - 0 " 37 ' - 0 " 6' - 7"6' - 7"2' - 3"2' - 7" 22 ' - 4 " 1' - 0 " 2' - 0 " 8080 OGD 1' - 5 " 6' - 0 " 45 ' - 0 " 1' - 8 " 4" 1' - 8 " 4' - 4 " 11 ' - 8 1 / 2 " 8080 OGD 40' - 0" 45 ' - 0 " 2 -3060 DH 13' - 2"4' - 10"22' - 0"PORCH 139 130130OPT. 2' - 7 " 9' - 1 1 1 / 2 " 1' - 5 1 / 2 " 7' - 0 " 21 ' - 0 " 126126 9' - 0 " 2- S T R Y CL G CL G A-2 A1.400 11' - 10"7' - 4"20' - 10" 2-CAR GARAGE 9' -0" CLG FLEX 9' -0" CLG O.E.9' - 0" CLG PANTRY 9' -0" CLG KITCHEN 2-STORY CLG FOYER 9' -0" CLG POWDER LINEN 9' -0" CLG DINING 9' -0" CLG FAMILY 21 0 6 8 21 0 6 8 21 0 6 8 2068 40 6 8 B P 3068 SC 2468 3 - 20 2 0 F X 20 4 0 D H 30 6 0 D H 3 -3060 DH3046 DH 30 6 0 D H 1 A1.500 19 ' - 0 1 / 2 " 2' - 4 1 / 2 " 3' - 1 0 1 / 2 " 1' - 8 " 2' - 2 1 / 2 " 5' - 7 1 / 2 " 2' - 1 0 " 3068 9' - 0"14' - 0"11' - 7"4' - 6 1/2" (2) 3068 FR DR (TEMP) 6' - 5 " 3' - 8 1 / 2 " 11 ' - 6 1 / 2 " DECK 2' - 1 1 1 / 2 " 21 ' - 8 " 17' - 0"12' - 0"11' - 0" 40' - 0" 6010 FX ABV. 12 ' - 0 " 12 ' - 0 " 3010 FX ABV. 39' - 1 1/2"10 1/2" 39' - 1 1/2" 10 1/2" 3' - 3"6' - 0 1/2"3' - 10 1/2"4' - 10"5"5' - 10"3' - 6 1/2"4' - 7 1/4"4' - 9 1/4"2' - 10" 9' - 3 1/2"3' - 10 1/2"4' - 10"15' - 0"7' - 0" 9' - 4 " 11 1 / 2 " 3' - 1 0 1 / 2 " 2' - 4 1 / 2 " 19 ' - 0 1 / 2 " 1' - 2 1 / 2 " 3' - 1 1 / 2 " 3' - 9 1 / 2 " 14 ' - 1 0 1 / 2 " 7 1 / 4 " 8 3 / 4 " 7 1 / 4 " 5' - 2 1 / 4 " 7 1 / 2 " 15 ' - 3 " 102101 104 103 12 2 10 9 10 8 10 8 10 9 109 124 117110112122 131 127128 129 129 2- S T R Y 9' - 0 " CL G C L G 2x6 WALL 2x 6 W A L L 2x6 WALL 133 123 OP T . 138 9'-0" CLG 2-STRY CLG 2x8 WALL 2x8 WALL 5' - 10"3' - 6 1/2"4' - 7 1/4"7 1/4" 131 145 150 152 IS S U E D A T E : RE V I S I O N S JOB NO: PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.110 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t MAIN FLOOR PLAN - ELEVATION A SCALE: 1/4" = 1'-0" Main Floor Plan -Elevation A AREA SCHEDULE - STANDARD - ELEV A Area Key AREA NAME AREA ELEVATION A A MAIN FLOOR LIVABLE 1171 SF B UPPER FLOOR LIVABLE 1045 SF LIVABLE 2216 SF C 2-CAR GARAGE 464 SF E PORCH 119 SF D DECK 143 SF E UNFINISHED BASEMENT 1016 SF NON-LIVABLE 1742 SF ELEVATION A 3958 SF GENERAL FLOOR PLAN NOTES • MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) • WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. • PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. • ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. • PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. • SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. • PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. • ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) • ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) • CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. • ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. • ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. • FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. FLOOR PLAN KEYNOTES 101 SINK W/ GARBAGE DISPOSAL. 102 DISHWASHER. 103 REFRIGERATOR. 104 RANGE W/ HOOD. 108 BASE CABINETS. 109 UPPER CABINETS. 110 WATER CLOSET. 112 PED. SINK. 117 LINEN SHELVES PER BUILDER SPEC. 122 ROD & SHELF. 123 ATTIC ACCESS. 124 HANDRAIL. 126 LINE OF OVERHEAD GARAGE DOOR IN OPEN POSITION. 127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD IN GARAGE AS REQUIRED BY CODE. 128 SLOPE GARAGE FLOOR 1/8" PER FOOT TOWARD GARAGE DOOR OPENING. 129 LINE OF FOUNDATION BELOW. 130 LINE OF SOFFIT ABOVE (REFER TO EXTERIOR ELEVATIONS FOR HEIGHTS AND DETAILS). 131 GYPSUM BOARD OPENING 8'-0" AT MAIN FLOOR & 7'-0" AT UPPER FLOOR. 133 LINE OF FRAMING ABOVE. 138 EXTERIOR GUARDRAIL W/ BALLUSTERS TO BE SPACED SUCH THAT 4" SPHERE CANNOT PASS BETWEEN BALUSTERS. 139 MASONRY WAINSCOT. 145 SHELF AT FINISH FLOOR LEVEL. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 152 TOWEL RING 48" A.F.F. DN 16 RISERS A-1 A1.400 1 A1.500 6' - 7"3' - 11" 10' - 6"2' - 10" 13' - 4"5' - 1 1/2"21' - 6 1/2" 40' - 0" 2' - 2"2' - 11 1/2" 2' - 11 1/2"3' - 10" 21 ' - 0 " 1' - 0 " 9' - 4"5' - 5"6' - 9 1/2" 13 ' - 0 " 11 ' - 5 " 37 ' - 0 " 6' - 0 " 2' - 0 " 50 6 8 B P 45 ' - 0 " 2 -3050 DH 2030 FX 11' - 10"7' - 4"20' - 10" 45 ' - 0 " 2030 DH 8' - 0 " 1' - 0 " 6' - 2 1 / 2 " 4' - 2 1 / 2 " 12 2 134 134134 A-2 A1.400 8' - 0 " BEDROOM 3 LAUNDRY OPEN TO BELOW OWNER'S BATH OWNER'S SUITE BEDROOM 2 W.I.C. BATH 2 3 - 30 5 0 D H 2 -3050 DH 2040 DH (2) 2068 2468 5068 BP 26 6 8 2468 2468 26 6 8 2668 24 6 8 2468 5' - 8 1 / 2 " 5' - 8 " 11 ' - 1 0 " 2' - 4 1 / 2 " 11 ' - 4 1 / 2 " 11 ' - 1 0 " 40' - 0" 10' - 6 1/2"9' - 3"6' - 4 1/2"13' - 10" 5' - 0 1/2"5' - 0 1/2"3' - 4"3' - 0 1/2"6' - 9 1/2"7' - 0 1/2" 3' - 1 0 " 4' - 3 1 / 2 " 14 ' - 1 0 1 / 2 " LOFT 23 ' - 0 " 6' - 9 1/2"3' - 9"3' - 5 1/2"5' - 9 1/2"6' - 4 1/2"13' - 10" 18' - 0"5"5' - 10"3' - 6 1/2"2' - 0"3' - 5"5' - 2"1' - 7 1/2" 122 110 12 2 12 2 11 0 124 132 117 11 4 2x6 WALL 111 116 11 1 11 1 113 118119 121 2' - 7 " 4' - 4 " 3' - 9 1 / 2 " 3' - 5 1 / 2 " 3' - 8 " 1' - 1 0 " 5' - 1 1 " 123 13' - 2"5' - 3 1/2" OP T 16 6 8 11 7 5' - 7 1 / 2 " 2' - 6 " 3' - 5 1 / 2 " 11 ' - 5 " 150 152 152 151 152150 2 -3050 DH IS S U E D A T E : RE V I S I O N S JOB NO: PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.120 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t UPPER FLOOR PLAN - ELEVATION A AREA SCHEDULE - STANDARD - ELEV A Area Key AREA NAME AREA ELEVATION A A MAIN FLOOR LIVABLE 1171 SF B UPPER FLOOR LIVABLE 1045 SF LIVABLE 2216 SF C 2-CAR GARAGE 464 SF E PORCH 119 SF D DECK 143 SF E UNFINISHED BASEMENT 1016 SF NON-LIVABLE 1742 SF ELEVATION A 3958 SF FLOOR PLAN KEYNOTES 110 WATER CLOSET. 111 LAV. SINK. 113 SHOWER (36X48). 114 SHOWER SEAT 18" A.F.F. 116 TUB/SHOWER (33X60). 117 LINEN SHELVES PER BUILDER SPEC. 118 WASHER. 119 DRYER. 121 LINE OF SHELF ABOVE. 122 ROD & SHELF. 123 ATTIC ACCESS. 124 HANDRAIL. 132 HALF WALL @ 36" A.F.F. W/ WOOD CAP. 134 LINE OF FRAMING BELOW. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. SCALE: 1/4" = 1'-0" Upper Floor Plan -Elevation A GENERAL FLOOR PLAN NOTES • MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) • WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. • PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. • ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. • PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. • SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. • PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. • ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) • ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) • CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. • ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. • ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. • FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. MAIN FLOOR MAIN PLATE 9' - 1 1 / 8 " UPPER FLOOR UPPER PLATE 8' - 1 1 / 8 " TOP OF FOUNDATION 8 12 8 12 8 12 8 12 8 12 8 12 8 12 (2) 2020 FX BLACKOUT @ 13'-3" 211 213 202 212 207 206 3' - 2 " OPT. OPT. 217 215 222 203 212 211 AD.3 1 3 AD.1 5 AD.2 4 AD.2 7 AD.1 10 AD.2 8 AD.1 11 AD.2 211 8' - 0 " 2' - 7 5 / 2 5 6 " 214 214 MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR 9' - 1 1 / 8 " 8' - 1 1 / 8 " 8 12 8 12 8 12 8' - 8 " 11 AD.2 7 AD.1 3 AD.1 222 212 213 202 211 223 7 AD.2 IS S U E D A T E : RE V I S I O N S JOB NO: PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.200 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t EXTERIOR ELEVATIONS - ELEVATION A EXTERIOR ELEV KEYNOTES 202 6" LAP SIDING. 203 SHAKE SIDING. 206 STONE VENEER. 207 STONE CAP. 211 1x8 FASCIA/RAKE. 212 5/4x6 FRIEZE TRIM. 213 5/4x6 CORNER TRIM. 214 5/4x4 TRIM. 215 5/4x6 TRIM. 217 5/4x10 TRIM. 222 COMPOSITION SHINGLES. 223 RAILING PER BUILDERS SPEC. SCALE: 1/4" = 1'-0" Front Elevation Elevation B -Craftsman EXTERIOR ELEVATION NOTES • REFER TO GENERAL NOTES AND DETAIL SHEETS FOR TYPICAL REQUIREMENTS AND MATERIALS SPECIFIC TO THIS PROJECT. • GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN. BUILDER SHALL VERIFY AND COORDINATE PER ACTUAL SITE CONDITIONS. • BUILDER TO PROVIDE ROOF AND SOFFIT VENTS SPECIFIED BY ATTIC VENT SCHEDULE, OR APPROVED EQUAL. • PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER. • INSTALL ALL PRE-MANUFACTURED MATERIALS PER MANUFACTURER'S REQUIREMENTS, RECOMMENDATIONS, AND SPECIFICATIONS. INSTALLATION REQUIREMENTS TO BE PROVIDED BY BUILDER. ALL ITEMS SHOWN ARE STANDARD U.N.O. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. SCALE: 1/4" = 1'-0" Rear Elevation MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR 9' - 1 1 / 8 " 8' - 1 1 / 8 " 8' - 8 " 6 12 4 12 8 AD.2 7 AD.1 11 AD.2 10 AD.2 1 AD.2 213 202 212 222 211 223 OPT. 8' - 0 " 215 215 AD.3 1 23 . 8 8 ’ PCG MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR 9' - 1 1 / 8 " 8' - 1 1 / 8 " 6 12 6 12222 202 213 5 AD.2 4 AD.2 1 AD.2 7 AD.1 11 AD.2 211 223 5 AD.2 4 AD.2 1 AD.2 7 AD.1 11 AD.2 OPT. OPT. OPT. 207 206 215 3' - 2 " 8' - 8 " IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.201 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t EXTERIOR ELEVATIONS - ELEVATION A EXTERIOR ELEV KEYNOTES 202 6" LAP SIDING. 203 SHAKE SIDING. 206 STONE VENEER. 207 STONE CAP. 211 1x8 FASCIA/RAKE. 212 5/4x6 FRIEZE TRIM. 213 5/4x6 CORNER TRIM. 214 5/4x4 TRIM. 215 5/4x6 TRIM. 217 5/4x10 TRIM. 222 COMPOSITION SHINGLES. 223 RAILING PER BUILDERS SPEC. Elevation B -Craftsman EXTERIOR ELEVATION NOTES •REFER TO GENERAL NOTES AND DETAIL SHEETS FOR TYPICAL REQUIREMENTS AND MATERIALS SPECIFIC TO THIS PROJECT. •GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN. BUILDER SHALL VERIFY AND COORDINATE PER ACTUAL SITE CONDITIONS. •BUILDER TO PROVIDE ROOF AND SOFFIT VENTS SPECIFIED BY ATTIC VENT SCHEDULE, OR APPROVED EQUAL. •PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER. •INSTALL ALL PRE-MANUFACTURED MATERIALS PER MANUFACTURER'S REQUIREMENTS, RECOMMENDATIONS, AND SPECIFICATIONS. INSTALLATION REQUIREMENTS TO BE PROVIDED BY BUILDER. ALL ITEMS SHOWN ARE STANDARD U.N.O. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. SCALE: 1/4" = 1'-0" Left Elevation SCALE: 1/4" = 1'-0" Right Elevation A-1 A1.400 6: 1 2 8:12 8:12 8:12 8:12 8:12 4: 1 2 2: 1 2CRICKET 8:12 TYP. 1' - 0" EAVE TYP. 1' - 0" RAKE 6:12 8:12 A-2 A1.400 1171 SF ZONE 1 580 SF ZONE 2 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.300 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t ROOF PLAN - ELEVATION A SCALE: 1/4" = 1'-0" Roof Plan -Elevation A NOTE: * REQUIRED NET FREE AREAS ARE CALCULATED BY MULTIPLYING THE ACTUAL ATTIC AREA (SQ FT) BY 1/300. 40%-50% OF TOTAL NET FREE VENTED AREA IS REQUIRED AT THE RIDGE (HIGH) WITH REMAINING REQUIRED IN THE SOFFIT (LOW). WHEN NO "HIGH / LOW" VENTING IS PROVIDED, THE REQUIRED NET FREE AREA IS 1/150 OF THE ACTUAL AREA. ATTIC VENTILATION SCHEDULE - ELEVATION A ZONE ATTIC AREA VENT RATIO REQUIRED UPPER VENTILATION REQUIRED LOWER VENTILATION ZONE 1 1171 SF 1 / 300 281 in² 281 in² ZONE 2 580 SF 1 / 300 139 in²139 in² CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE 8' - 1 1/8" TOP OF FOUNDATION BASEMENT FLOOR HEEL 1' - 4" A1 B1 C1 D1 C1 FOYER PORCHFAMILY LOFTBATH 2 STORAGE UNFINISHED BASEMENT 9' - 0"22' - 1 45/256" ROOF TRUSS @24" O.C. 13' - 10 211/256"6' - 1 45/256" HEEL 4" 6 12 6 12 4 12 45' - 0" 4' - 0" GIRDER TRUSS GIRDER TRUSS 9' - 1 1/8" 8' - 8" MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR A1 B1 C1 D1 C1 UNFINISHED BASEMENT PANTRYKITCHEN OWNER'S SUITE OWNER'S BATH 2-CAR GARAGE 21' - 0" ROOF TRUSS @24" O.C. 23' - 0" 44' - 0" 6 12 6 12 HEEL 1' - 4" 4' - 0" IS S U E D A T E : RE V I S I O N S JOB NO: PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.400 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t BUILDING SECTIONS - ELEVATION A Building Sections Elevation B -Craftsman SCALE: 1/4" = 1'-0" Section A-1 CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. SCALE: 1/4" = 1'-0" Section A-2 MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR 9' - 1 1/8" 8' - 1 1/8" PANTRY FAMILY LOFTOWNER'S BATH 8 RISERS 8 RISERS 8 RISERS 7 RISERS LANDING 3' - 6 1/2" 7 TREADS @ 10" EA = 5' - 10" MIN. CLEARANCE 6' - 8" MIN. CLEARANCE 6' - 8" 3'-2" MAX. 2'-10" MIN. 6 TREADS @ 10" EA. = 5' - 0" LANDING 3' - 5 1/2" 7 TREADS @ 10" EA. = 5' - 10" LANDING LANDING 16 EQUAL RISERS 15 EQUAL RISERS 8' - 8" IS S U E D A T E : RE V I S I O N S JOB NO: PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.500 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t STAIR SECTION1Stair Section SCALE: 1/4" = 1'-0" UP 15 RISERS 1 A1.500 8' -9" CLG FAMILY 8' -9" CLG STORAGE STOR. 10" 3" 20' - 7" 24 6 8 10"3"2' - 11" 1' - 10 1/2" 2' - 0"3' - 10 1/2"6' - 3"2' - 9 1/2"3' - 6 1/2"3' - 5 1/2"11' - 1 1/2" 3" 10" 017 004 010 4' - 6"6' - 5"6' - 3" SIM. 2x6 WALL 8' -9" CLG BEDROOM 4 8' - 9" CLG BATH 3 266821068 21068 20 6 8 117 122 111 110 116 11 7 10" 9' - 8 1/2" 4' - 4 1/2" 1' - 1 1/2" 5' - 3 1/2" 11 1/2" 3' - 4 1/2" 11' - 4" 30 6 8 WH 16 RISERS AS REQUIRED STORM SUMP 151 152 150 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 6/13/2024 11:42:16 AM C:\Users\charlotte\O'Brien Brothers Agency, Inc\Home Building - Neighborhoods\Hillside East\Revit Plans\SF-2_R2019 Mirrored.rvt A1.600 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t FLOOR PLAN OPTIONS - ALL ELEVATIONS 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 FLOOR PLAN KEYNOTES 004 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS UNDER ACCESSIBLE ENCLOSED STAIRS. 010 HANDRAIL. 017 GYPSUM BOARD OPENING 7'-6" AT BASEMENT. 110 WATER CLOSET. 111 LAV. SINK. 116 TUB/SHOWER (33X60). 117 LINEN SHELVES PER BUILDER SPEC. 122 ROD & SHELF. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. GENERAL FLOOR PLAN NOTES •MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) •WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. •PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. •ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. •PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. •SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. •PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. •ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) •ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) •CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. •ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. •ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. •FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. NOTE: SEE STANDARD FLOOR PLANS, ELECTRICAL PLANS, ROOF PLANS, AND ELEVATIONS, FOR INFORMATION NOT SHOWN, IN AREAS ADJACENT TO OPTIONS, THAT DOES NOT CHANGE. Floor Plan Options All Elevations Similar SCALE: 1/4" = 1'-0" Optional Finish Basement Plan WP SD CO WP SD CO WP / G F C I 3 TO FIXTURE ABOVE HRV AI R H A N D L E R IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . E1.100 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t BASEMENT ELECTRICAL PLAN - ELEVATION A GENERAL ELECTRICAL NOTES A. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G. FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H. KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J. ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K. CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L. SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M. ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N. ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O. PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P. PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q. OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R. LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S. UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T. NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U. CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V. ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER SCALE: 1/4" = 1'-0" Basement Electrical Plan -Elevation A D WP SD CO SD WP D WP WP 50 A TV CH WP SD CO SD WP 50 A TV CH 3 WP/GFCI WP/GFCI GFCIGFCI TO FIXTURE ABOVE TO FIXTURE ABOVE TO SWITCH BELOW GFCI 4 3 33 3 220V GF C I GF C I GFCI GFCI +84" AFF GFCI GFCI GF C I GF C I GF C I WP / G F C I CHANDELIER 3 3 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . E1.110 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t MAIN FLOOR ELECTRICAL PLAN - ELEVATION A SCALE: 1/4" = 1'-0" Main Floor Electrical Plan -Elevation A GENERAL ELECTRICAL NOTES A. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G. FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H. KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J. ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K. CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L. SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M. ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N. ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O. PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P. PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q. OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R. LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S. UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T. NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U. CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V. ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER SD C O SD SD SD WP TV TV TV SD CO 30A SD C O SD SD SD WP TV TV TV SD CO 30A TO SWITCH BELOW TO SWITCH BELOW PEND GFCI 3 4 TO SWITCH BELOW GFCI GF C I GF C I IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . E1.120 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t UPPER FLOOR ELECTRICAL PLAN - ELEVATION A SCALE: 1/4" = 1'-0" Upper Floor Electrical Plan -Elevation A GENERAL ELECTRICAL NOTES A. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G. FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H. KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J. ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K. CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L. SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M. ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N. ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O. PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P. PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q. OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R. LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S. UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T. NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U. CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V. ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER WP SD CO SDTV TV TO FIXTURE ABOVE WP / G F C I 3 3 GFCI GF C I IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . E1.600 PLAN SF-2 SF210303.00 JA -- JM 09 -13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t FLOOR PLAN OPTION - ELECTRICAL PLANS GENERAL ELECTRICAL NOTES A. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G. FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H. KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J. ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K. CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L. SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M. ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N. ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O. PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P. PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q. OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R. LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S. UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T. NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U. CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V. ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER NOTE: SEE STANDARD FLOOR PLANS, ELECTRICAL PLANS, ROOF PLANS, AND ELEVATIONS, FOR INFORMATION NOT SHOWN, IN AREAS ADJACENT TO OPTIONS, THAT DOES NOT CHANGE. SCALE: 1/4" = 1'-0" Opt. Finish Basement -Electrical Plan Floor Plan Options All Elevations Similar