HomeMy WebLinkAboutMP-24-02 - Supplemental - 0200 da Vinci Drive (12)Project Catalog #Type Prepared by Notes Date PS517016EN page 1 November 8, 2023 3:26 PM Top Product Features • New construction/remodel series; 500 to 6,000 lumens • Narrow, Medium and Wide distributions; Wall wash with rotatable linear spread lens • 2700K, 3000K, 3500K, 4000K, 5000K CCT; 80 or 90 CRI • Universal voltage 120V-277V; Standard 0-10V driver dims to 1% • Mounting frame converts to remodel that installs from below the ceiling • Rapid Response emergency backup mounting frames - fast delivery option Dimensional and Mounting Details HC6 | HM6 | 61 | 61PS 6-inch LED downlight and wall wash Typical Applications Office • Healthcare • Hospitality • Institutional • Mixed-Use/Retail Interactive Menu • Order Information page 2 • Product Specifications page 4 • Photometric Data page 5 • Energy & Performance Data page 8 • Connected Systems page 10 • Product Warranty additionalproduct diagrams NEW CONSTRUCTION - MID LUMEN3000 AND 4000 LUMEN NEW CONSTRUCTION - HIGH LUMEN4500 – 6000 LUMEN .5"[12.70mm](ceiling thickness) 6.06" [153.92mm](reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm] (trim flange) trim height (see table) max module height(see table) LED height(see table)3.42"[86.77mm](driver height) .5"[12.70mm](ceiling thickness) 6.05" [153.72mm](reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm] (trim flange) trim height (see table) max module height(see table) LED height(see table)3.42"[86.77mm](driver height) 6.06" [153.92mm](reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm] (trim flange) trim height (see table) LED height (see table) max moduleheight (see table) .5"[12.70mm](ceiling thickness) NEW CONSTRUCTION - LOW LUMEN500 – 2500 LUMENS 4.2"[107.34mm] hanger bar bracketheight (removable) 3.42"[86.77mm](driver height) 8.6"[217.35mm] 26.4"[670.56mm] NEW CONSTRUCTION - MID LUMEN3000 AND 4000 LUMEN NEW CONSTRUCTION - HIGH LUMEN4500 – 6000 LUMEN .5" [12.70mm](ceiling thickness) 6.06" [153.92mm](reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) max module height (see table) LED height(see table)3.42" [86.77mm](driver height) .5" [12.70mm](ceiling thickness) 6.05" [153.72mm](reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) max module height (see table) LED height(see table)3.42" [86.77mm](driver height) 6.06" [153.92mm](reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) LED height(see table) max module height(see table) .5"[12.70mm] (ceiling thickness) NEW CONSTRUCTION - LOW LUMEN500 – 2500 LUMENS 4.2" [107.34mm]hanger bar bracketheight (removable) 3.42" [86.77mm](driver height) 8.6"[217.35mm] 26.4"[670.56mm] Mid Lumen (3000 – 4000 Lumens) Distribution Max. Module Height Trim Height LED Height Narrow 6.6"3.4”3.8” Medium 6.7”3.5”3.9” Wide 6.5”3.3”3.7” Baffle 6.5”3.3”3.7” Product Certification Product Features Control Compatibility LITEWaveLinx PROWaveLinx Mounting Frame Order Information Sample Number: HC620D010REM7 – HM60525835 - 61MDC A complete luminaire consists of a housing frame, LED module, and reflector (ordered separately) Mounting Frame Lumens Driver Options Factory Installed Emergency & Connected Lighting Options Accessories (Order & Install Separately) HC6 = 6" new construction downlight housing HC6CP = 6" new construction housing, Chicago Plenum - CCEA compliant 05 = 500 lm 07 = 750 lm 10 = 1000 lm 15 = 1500 lm 20 = 2000 lm 25 = 2500 lm 30 = 3000 lm 35 = 3500 lm 40 = 4000 lm 45 = 4500 lm (7) 50 = 5000 lm (7) 55 = 5500 lm (7) 60 = 6000 lm (7) D010=UNV 120-277V, 50/60Hz, 0-10V 1%-100% dimming at 120-277V on 0-10V controls Canada Option 500-5000 lumens:D010347 = 347VAC 50/60Hz 0-10V 1%-100% dimming. For 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000lm models only (1) Canada Option 5500-6000 lumens:D010X347 = step down transformer factory installed (with standard “D010" 120V-277V LED driver). For 5500, 6000lm models only (1) REM7 = 7 watt emergency battery pack with remote test / indicator light, use with D010 only (1) (2) (6) REM14 = 14 watt emergency battery pack with remote test / indicator light, use with D010 only (1) (2) (6) IEM7 = 7 watt emergency battery pack with integral test / indicator light, use with D010 only (1) (2) (6) IEM14 = 14 watt emergency battery pack with integral test / indicator light, use with D010 only (1) (2) (6) BOD7ST = 7.5 watt Bodine self-test emergency battery pack with remote test / indicator light, use with D010 only (1) (2) (6) WTA = Factory WaveLinx Tilemount Sensor Kit (4) WTK = Factory WaveLinx LITE Commercial Tilemount Sensor Kit (5) WPN = WaveLinx PRO Wireless Node without sensor (9) HB128APK = L channel hanger bar, 26”, pair (replacement) RMB22 = Adjustable wood joist mounting bars, pair, extend to 22” long HSA6 = Slope Adapter for 6” Aperture Housings, Specify Slope (refer to instructions for installing housing and trim) H347 = 347 to 120V step down transformer, 75VA H347200 = 347 to 120V step down transformer, 200VA WTA = Field WaveLinx Tilemount Sensor Kit (4) WTK = Field WaveLinx LITE Commercial Tilemount Sensor Kit (5)DLV = Distributed Low Voltage dimming driver 1%-100%, 1000-4000 lumens only. For use with DLVP system only, refer to DLVP specifications for details. (1) REMV7 = 7 watt emergency battery pack with remote test / indicator light, use with DLV only (1) (2) (3) (6) REMV14 = 14 watt emergency battery pack with remote test / indicator light, use with DLV only (1) (2) (3) (6) IEMV7 = 7 watt emergency battery pack with integral test / indicator light, use with DLV only (1) (2) (3) (6) IEMV14 = 14 watt emergency battery pack with integral test / indicator light, use with DLV only (1) (2) (3) (6) Notes Notes Notes Notes Notes (7) Marked Spacing: Center to Center of Adjacent Luminaires = 36”Center of Luminaire to Building Member = 18”Minimum overhead = 0.5 (1) Not available with CP models (1) Not available with CP models(2) Not available with D010347 (347V models)(3) ULus for U.S. only(4) WTA = WaveLinx tilemount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS - Real Time Location Services, use with D010 only (Refer to WaveLinx specifications) (5) WTK = WaveLinx LITE tilemount sensor kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to WaveLinx LITE specifications)(6) Emergency battery backup options are Non-IC only, and rated for a minimum starting temperature of 0°C (9) WPN = WaveLinx PRO wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. (4) WTA = WaveLinx tilemount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS - Real Time Location Services, use with D010 only (Refer to WaveLinx specifications) (5) WTK = WaveLinx LITE tilemount sensor kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to WaveLinx LITE specifications) Rapid Response Emergency Mounting Frame Order Information Sample Number : Rapid Response Emergency Mounting Frame: RR-HC620D010REM7LED module and reflectors are ordered separately. Order separately: LED Module: HM60525835 | Reflector: 61MDC RR Code Mounting Frame Lumens Driver Options Factory Installed Emergency & Connected Lighting Options Accessories (Order & Install Separately) RR = East RegionBRR = West Region HC6 = 6" new construction downlight housing 10 = 1000 lm 15 = 1500 lm 20 = 2000 lm 30 = 3000 lm 40 = 4000 lm D010=UNV 120-277V, 50/60Hz, 0-10V 1%-100% dimming at 120-277V on 0-10V controls REM7 = 7 watt emergency battery pack with remote test / indicator light, use with D010 only (2) (6) REM14 = 14 watt emergency battery pack with remote test / indicator light, use with D010 only (2) (6) IEM7 = 7 watt emergency battery pack with integral test / indicator light, use with D010 only (2) (6) IEM14 = 14 watt emergency battery pack with integral test / indicator light, use with D010 only (2) (6) HB128APK = L channel hanger bar, 26”, pair (replacement) RMB22 = Adjustable wood joist mounting bars, pair, extend to 22” long Notes Notes Notes Notes Notes Notes (2) Not available with D010347 (347V models)(6) Emergency battery backup options are Non-IC only, and rated for a minimum starting temperature of 0°C Select from the Rapid Response Mounting Frame ordering information to receive the Fast Delivery option for the frame. HC6 | HM6 | 61 | 61PS PS517016EN page 2 November 8, 2023 3:26 PM IEM Reflector Distribution(8)Finish Flange Integral Emergency 61 = 6” IEM reflector for integral emergency only ND = narrow 55° beam angle 0.97 SCMD = medium 60° beam angle 1.10 SCWD = wide 65° beam angle 1.28 SC C = Specular clearH = Semi-specular clearW = White Blank = Polished flange standard with C & H reflectorsBlank = White flange standard with W reflectorWF = White flange option available with C & H reflectors IEM = Reflector for use with integral emergency housings only. Provides access hole for integral emergency test switch. Notes Notes Notes Notes Notes (8) Values are nominal, with specular clear reflector, other finishes and field results may vary. IEM Baffle Distribution(8)Finish Flange Integral Emergency 61 = 6” IEM baffle reflector for integral emergency only WD = wide 65° beam angle 1.28 SC (nominal)BB = Black baffleWB = White baffle Blank = White flange standard with BB, & WBBF = Black flange option with BB IEM = Reflector for use with integral emergency housings only. Provides access hole for integral emergency test switch. Notes Notes Notes Notes Notes (8) Values are nominal, with specular clear reflector, other finishes and field results may vary. Reflector Distribution(8)Finish Flange 61PS = 6” non-conductive polymer ‘dead front’ conical reflector (9)MD = medium 60° beam angle 1.10 SC (nominal)W = White Blank = White flange standard with W reflector Notes Notes Notes Notes (9) 61PS is 1000-2000 lumens Non-IC rated. 500 & 750 lumens IC rated. 61PS is not for use over 2000lm in Non-IC or over 750lm in IC.(8) Values are nominal, with specular clear reflector, other finishes and field results may vary. Reflector Distribution(8) Finish Flange Accessories 61 = 6” conical reflector ND = narrow 55° beam angle 0.97 SCMD = medium 60° beam angle 1.10 SCWD = wide 65° beam angle 1.28 SCRWW = rotatable wall wash with linear spread lens C = Specular clearH = Semi-specular clearW = White Blank = Polished flange standard with C & H reflectorsBlank = White flange standard with W reflectorWF = White flange option available with C & H reflectors 61RWWPK = Replacement part kit - wall wash lens insert - for use with 61RWW* only. Notes Notes Notes Notes Notes (8) Values are nominal, with specular clear reflector, other finishes and field results may vary. Baffle Distribution(8)Finish Flange Accessories 61 = 6” baffle reflector WD = wide 65° beam angle 1.28 SC (nominal)RWW = rotatable wall wash with linear spread lens BB = Black baffleWB = White baffle Blank = White flange standard with BB, & WBBF = Black flange option available with BB 61RWWPK = Replacement part kit - wall wash lens insert - for use with 61RWW* only. Notes Notes Notes Notes Notes (8) Values are nominal, with specular clear reflector, other finishes and field results may vary. Trim Order Information LED Module Order Information LED Module Lumens CRI/CCT HM6 = 6" LED Modules For use with HC6 - HC6CP New Construction housings only 0525 = 500 - 2500 lumen 3040 = 3000-4000 lumen 4560 = 4500-6000 lumen 827 = 80CRI, 2700K830 = 80CRI, 3000K835 = 80CRI, 3500K840 = 80CRI, 4000K850 = 80CRI, 5000K 927 = 90CRI, 2700K930 = 90CRI, 3000K935 = 90CRI, 3500K940 = 90CRI, 4000K950 = 90CRI, 5000K Notes Notes Notes HC6 | HM6 | 61 | 61PS PS517016EN page 3 November 8, 2023 3:26 PM Product Specifications Housing Frame• Boat shaped galvanized steel plaster frame with adjustable plaster lip • Accommodates 1/2" to 1-1/2" thick ceilings • Installs in new construction or from below the finished ceiling (non-accessible) for remodeling (with mounting bars removed) • Provided with two remodel clips to secure the frame to the ceiling Universal Mounting Bracket • Adjusts 2" vertically from above and below the ceiling • Use with the included mounting bars or with 1/2" Electric Metallic Tube (EMT) • Removable to facilitate remodeling installation from below the finished ceiling Mounting Bars • Captive pre-installed No Fuss™ mounting bars lock to T-grid with screwdriver or pliers • Centering detents allow for consistent positioning of fixtures LED Module• Proximity phosphors over chip on board LEDs provide a uniform source with high efficiency and no pixilation • Available in 80 or 90 color rendering index (CRI) • Color accuracy within 3 SDCM provides color consistency and uniformity • 90 CRI option: R9>50 (refer to chromaticity information for details) • Available in 2700K, 3000K, 3500K, 4000K and 5000K correlated color temperature (CCT) • Lumen options include 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000, 5500, 6000 lumens (nominal) • Passive thermal management achieves 60,000 hours at 70% lumen maintenance (L70) in insulated ceilings (IC) and non-IC applications • Integral diffuse lens provides visual shielding • Integral connector allows quick connection to housing flex Reflector• Self-flanged aluminum reflectors available in narrow, medium or wide distribution patterns • Medium distribution polymer non-conductive matte white reflector may be used to meet local codes for ‘dead front’ applications (500 & 750 lumen max. in IC and 2000 lumen max. in Non-IC) • Wall wash reflector features a rotatable linear spread lens for alignment of vertical illumination • Reflectors attach to LED module with three speed clamps • Available in multiple painted or plated finishes Reflector/Module Retention • Reflector/module assembly is securely retained in the housing with two torsion springs Driver • Field-replaceable constant current driver provides low noise operation • Universal 120-277VAC 50/60Hz input standard • Continuous, 1% to 100% dimming with 0-10V analog control • Optional low-voltage DC driver for use with Distributed Low Voltage Power (DLVP) system • Distributed Low Voltage Power (DLVP) system combines power, lighting and controls with ease of installation (refer to DLVP Design Guide at www.cooperlighting.com for details) Canada Options • 347VAC 50/60Hz; 1% dimming on 0 -10V analog control, for 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 lumen models only • 347V step down transformer factory installed with the standard “D010” 120V-277V, LED driver on 5500, 6000 lumen models only Emergency Option • Provides 90 minutes of standby lighting, meeting most life safety codes for egress lighting • Available with integral or remote charge indicator and test switch • Available Self-Test (self-diagnostic) with remote charge indicator and test switch • Rapid Response emergency ordering option for quick-turn projects Connected Lighting System Two WaveLinx connected solutions to choose from. Refer to WaveLinx system specifications and application guides for details. WaveLinx PRO Tilemount Sensor Kit • WaveLinx WTA tilemount sensor kit offers daylight dimming, PIR motion sensing, scene and zone configuration, automatic commissioning; and optional RLTS - Real Time Location Services available. WaveLinx PRO Wireless Node • WaveLinx PRO wireless node provides luminaire- level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. WaveLinx LITE Tilemount Sensor Kit • WaveLinx LITE WTK tilemount sensor kit offers daylight dimming and PIR motion sensing, scene and grouping configuration. WaveLinx Tilemount Kits Application • The WTA and WTK tilemount kits include a control module mounted on the luminaire junction box via 1/2” knock-out, and a tilemount sensor on 54-inch whip; for ceiling installation by direct-mount spring clips or via mounting bracket in octagon ceiling boxes. • The WTA and WTK tilemount kits may be ordered as factory installed on the luminaire, or ordered separately as a field installed accessory kit. Junction Box • Galvanized steel junction box • 20 in3 internal volume excluding voltage barrier • 25 in3 internal total volume • Voltage barrier for 0-10V dimming wires (occupies one 1/2" pry-out space) • Listed for eight #12 AWG (four in, four out) 90˚C conductors and feed-thru branch wiring • Three 1/2" and two 3/4" trade size pry-outs available • Three 4-port push wire nuts for mains voltage with 1-port for fixture connection Compliance • cULus Certified to UL 1598 / C22.2 No. 250.0, suitable for damp locations and wet locations in covered ceilings only • Emergency options provided with UL Listed emergency drivers to UL 924 / C22.2 No. 141, suitable for indoor/damp locations • IP20 - Above finished ceiling; IP65 - Below finished ceiling • Non-Insulated ceiling (Non-IC) rated for 2500, 3000, 3500, 4000, 4500, 5000, 5500, 6000 lumen models (insulation must be kept 3" from top and sides) • Insulated ceiling (IC) rated for 500, 750, 1000, 1500, 2000 lumen models and suitable for direct contact with air permeable insulation* (IC models are also suitable for Non-IC installations) • Non-IC marked spacing required for 4500, 5000, 5500, 6000 lumen models −Marked Spacing Center to Center of Adjacent Luminaires = 36” −Center of Luminaire to Building Member = 18” −Minimum overhead = 0.5” • Airtight per ASTM-E283-04 • Suitable for use in clothes closets when installed in accordance with the NEC 410.16 spacing requirements • EMI/RFI emissions FCC CFR Title 47 Part 15 Class A at 120/277V • Contains no mercury or lead and RoHS compliant • Photometric testing completed in accordance of IES LM-79-08 • Lumen maintenance projection in accordance of IES LM-80-08 and TM-21-11 • 500, 750, 1,000, 1,500 and 2,000 lumen, 90 CRI, ICAT models may be used to comply with State of California Title 24 residential code, per JA8 certification standards • May be used to comply with State of California Title 24 non-residential code as a dimmable LED luminaire • ENERGY STAR® certified, reference certified light fixtures database *Not for use in direct contact with spray foam insulation, consult NEMA LSD57-2013 Warranty • Five year limited warranty, consult website for details. www.cooperlighting.com/legal HC6 | HM6 | 61 | 61PS PS517016EN page 4 November 8, 2023 3:26 PM Note: Refer to IES files for more product data. Photometric Data View IES files NARROW DISTRIBUTION - SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 1636 73.4 0-40 2098 94.2 0-60 2223 99.8 0-90 2228 100 90-180 0 0 0-180 2228 100 CANDELA TABLE DegreesVertical Candela 0 2427 5 2422 15 2405 25 1621 35 761 45 118 55 12 65 3 75 2 85 0 90 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 9187 55 1118 65 376 75 318 85 0 CONE OF LIGHT MH FC L W 5.5'80.2 5 5 7'49.5 6.4 6.4 8'37.9 7.4 7.4 9'30 8.2 8.2 10'24.3 9.2 9.2 12'16.9 11 11 0ºD ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 1671 72.4 0-40 2163 93.8 0-60 2301 99.7 0-90 2307 100 90-180 0 0 0-180 2307 100 CANDELA TABLE DegreesVertical Candela 0 1998 5 2022 15 2307 25 1842 35 796 45 126 55 15 65 4 75 2 85 0 90 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 9753 55 1395 65 571 75 318 85 0 CONE OF LIGHT MH FC L W 5.5'68.7 5.6 5.6 7'42.4 7.2 7.2 8'32.5 8.2 8.2 9'25.7 9.4 9.4 10'20.8 10.4 10.4 12'14.4 12.4 12.4 0ºD MEDIUM DISTRIBUTION - SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K MEDIUM (60° BEAM*) Test Number P581875 Housing HC620D010 Module HM60525835 Reflector 61MDC Lumens 2307 Lm Efficacy 115.3 Lm/W SC 1.06 UGR 11.8 NARROW (55° BEAM*) Test Number P581878 Housing HC620D010 Module HM60525835 Reflector 61NDC Lumens 2228 Lm Efficacy 111.4 Lm/W SC 0.93 UGR 11.7 CANDLEPOWER DISTRIBUTION Downlight 0-deg 45-deg 90-deg 180°170°160°150°140° 130° 120° 110° 100° 90° 80° 70° 60° 50°40°30°20°10°0° 2434 1826 1217 609 0 CANDLEPOWER DISTRIBUTION Downlight 0-deg 45-deg 90-deg 180°170°160°150°140° 130° 120° 110° 100° 90° 80° 70° 60° 50°40°30°20°10°0° 2376 1782 1188 594 0 HC6 | HM6 | 61 | 61PS PS517016EN page 5 November 8, 2023 3:26 PM WIDE DISTRIBUTION - SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 1461 61.9 0-40 2105 89.2 0-60 2351 99.6 0-90 2359 100 90-180 0 0 0-180 2359 100 CANDELA TABLE DegreesVertical Candela 0 1526 5 1540 15 1685 25 1861 35 1027 45 252 55 32 65 6 75 2 85 0 90 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 19506 55 3078 65 765 75 318 85 0 CONE OF LIGHT MH FC L W 5.5'50.5 7 7 7'31.2 8.8 8.8 8'23.9 10.2 10.2 9'18.8 11.4 11.4 10'15.3 12.8 12.8 12'10.6 15.4 15.4 0ºD WIDE (65° BEAM*) Test Number P581885 Housing HC620D010 Module HM60525835 Reflector 61WDC Lumens 2359 Lm Efficacy 118 Lm/W SC 1.28 UGR 11.6 *Value are nominal with specular clear reflectors, other finishes and field results may vary.SC = Spacing CriteriaUGR = Unified Glare Rating Note: Refer to IES files for more product data. CANDLEPOWER DISTRIBUTION Downlight 0-deg 45-deg 90-deg 180°170°160°150°140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40°30°20°10°0° 1876 1407 938 469 0 CCT Multipliers – 90CRI 2700K 3000K 3500K 4000K 5000K 0.77 0.84 0.89 0.90 0.90 Multipliers for relative lumen values with other series color temperatures. CCT Multipliers – 80CRI 2700K 3000K 3500K 4000K 5000K 0.92 0.98 1.00 1.03 1.03 Multipliers for relative lumen values with other series color temperatures. Color Finish Multipliers Finish code C H W/WB BB Finish Specular Clear Semi-Specular Matte WhiteWhite Baffle Black Baffle Multiplier 1.00 0.92 0.91 0.82 Multipliers for relative lumen values with other color finishes. Photometric Multipliers (Nominal Lumen Values) 500 Lumen 750 Lumen 1000 Lumen 1500 Lumen 2000 Lumen 2500 Lumen 3000 Lumen 3500 Lumen 0.33 0.44 0.54 0.74 1.00 1.12 1.46 1.76 4000 Lumen 4500 Lumen 5000 Lumen 5500 Lumen 6000 Lumen 1.81 2.17 2.28 2.38 2.65 Multipliers for relative lumen values with other series models. Photometric Data View IES files HC6 | HM6 | 61 | 61PS PS517016EN page 6 November 8, 2023 3:26 PM WALL WASH DISTRIBUTION - SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K WALL WASH Test Number P581882 Housing HC620D010 Module HM60525835 Reflector 61RWWC Lumens 2179 Lm Efficacy 109 Lm/W SC 1.15 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 849 39 0-40 1313 60.2 0-60 1978 90.8 0-90 2179 100 90-180 0 0 0-180 2179 100 CANDELA TABLE DegreesVertical Candela 0 1080 5 1081 15 1112 25 1034 35 800 45 514 55 319 65 184 75 85 85 12 90 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 39810 55 30479 65 23907 75 17983 85 7359 SINGLE UNIT FOOTCANDLES 2.5' from wall(distance from fixture along wall) 1 19.3 13.8 6.1 2.2 0.7 0.3 0.1 2 29.1 22.6 12.3 5.7 2.5 1.2 0.6 3 27.6 22.5 13.8 7.3 3.7 1.9 1 4 21 18.2 12.4 7.4 4.2 2.4 1.4 5 14.4 13.1 9.9 6.6 4.1 2.5 1.6 6 9.7 9.1 7.5 5.5 3.7 2.5 1.6 7 6.7 6.4 5.5 4.3 3.2 2.2 1.5 8 4.7 4.6 4.1 3.4 2.7 2 1.4 9 3.4 3.3 3.1 2.7 2.2 1.7 1.3 10 2.5 2.5 2.4 2.1 1.8 1.4 1.1 MULTIPLE UNIT FOOTCANDLES 2.5' from wall(Distance from fixture along wall) 2.5’ from wall(Distance from fixture along wall) 1 21.5 19.1 21.5 20 12.1 20 2 34.7 34.4 34.7 31.6 24.6 31.6 3 34.9 36 34.9 31.3 27.6 31.3 4 28.4 30.7 28.4 25.2 24.8 25.2 5 21 23.2 21 18.6 19.8 18.6 6 15.2 16.8 15.2 13.4 15 13.4 7 11 12 11 9.9 11 9.9 8 8.1 8.7 8.1 7.4 8.2 7.4 9 6.1 6.5 6.1 5.6 6.2 5.6 10 4.6 4.9 4.6 4.3 4.7 4.3 43 SC = Spacing Criteria, nominal for specular clear reflector, other finishes and field results may vary. Note: Refer to IES files for more product data. CCT Multipliers – 90CRI 2700K 3000K 3500K 4000K 5000K 0.77 0.84 0.89 0.90 0.90 Multipliers for relative lumen values with other series color temperatures. CCT Multipliers – 80CRI 2700K 3000K 3500K 4000K 5000K 0.92 0.98 1.00 1.03 1.03 Multipliers for relative lumen values with other series color temperatures. Color Finish Multipliers Finish code C H W/WB BB Finish Specular Clear Semi-Specular Matte WhiteWhite Baffle Black Baffle Multiplier 1.00 0.92 0.91 0.82 Multipliers for relative lumen values with other color finishes. Photometric Multipliers (Nominal Lumen Values) 500 Lumen 750 Lumen 1000 Lumen 1500 Lumen 2000 Lumen 2500 Lumen 3000 Lumen 3500 Lumen 0.33 0.44 0.54 0.74 1.00 1.12 1.46 1.76 4000 Lumen 4500 Lumen 5000 Lumen 5500 Lumen 6000 Lumen 1.81 2.17 2.28 2.38 2.65 Multipliers for relative lumen values with other series models. CANDLEPOWER DISTRIBUTION Downlight 0-deg 45-deg 90-deg 180°170°160°150°140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40°30°20°10°0° 1112 834 556 278 0 Photometric Data View IES files HC6 | HM6 | 61 | 61PS PS517016EN page 7 November 8, 2023 3:26 PM Energy & Performance Data COLOR METRICS - TM-30-15 & CRI/CIE (3500K) 80 CRI Color Metric Summary - 3500K*90 CRI Color Metric Summary - 3500K* 3000K2700K 5000K4000K3500K 60° medium Nominal Beam 3000K2700K 5000K4000K3500K 65°55° widenarrow 60° medium Nominal Beam 65°55° widenarrow Minimum starting temperature -30°C (-22°F)* (Nominal input 120-277VAC & 100% of rated output power) Sound Rating: Class A standards Notes:* Emergency Battery packs are rated for a minimum starting temperature of 0°C. Series 500 lumen 750 lumen 1000 lumen 1500 lumen 2000 lumen Input Voltage 120-277VAC 120V 277V 120V 277V 120V 277V 120V 277V 120V 277V Input Current (A)0.051 0.026 0.067 0.036 0.083 0.039 0.119 0.053 0.171 0.077 Input Power (W)6.1 6.5 7.9 8.3 10 10.4 14.5 14.5 20.9 20.6 In-rush (A) 1.9 8.4 2 8.4 2.2 8.5 2.7 8.5 2.1 9.7 Inrush duration (µs)251 135 237 133 250 134 250 139 245 131 THD (%)6.2 13.5 7.4 8.8 5.4 10.3 10 6.7 6.5 7.9 PF ≥ 0.99 ≥ 0.9 ≥ 0.98 ≥ 0.92 ≥ 0.99 ≥ 0.95 ≥ 0.99 ≥ 0.97 ≥ 0.99 ≥ 0.96 Series 2500 lumen 3000 lumen 3500 lumen 4000 lumen 4500 lumen Input Voltage 120-277VAC 120V 277V 120V 277V 120V 277V 120V 277V 120V 277V Input Current (A)0.23 0.103 0.24 0.107 0.292 0.152 0.351 0.159 0.384 0.172 Input Power (W)27.5 27.5 28.6 28.5 34.6 35.1 42.1 42.1 45.9 45.6 In-rush (A) 2.5 5.6 2.5 11.6 3.4 13.9 3.1 14.7 3.1 14.8 Inrush duration (µs)232 123 216 111 183 95 200 98 202 100 THD (%)6.5 8.1 7.8 8.3 5.6 10 4.1 9.5 4.5 8.5 PF ≥ 0.99 ≥ 0.96 ≥ 0.99 ≥ 0.96 ≥ 0.99 ≥ 0.93 ≥ 0.99 ≥ 0.94 ≥ 0.99 ≥ 0.95 Series 5000 lumen 5500 lumen 6000 lumen Input Voltage 120-277VAC 120V 277V 120V 277V 120V 277V Input Current (A)0.419 0.186 0.457 0.201 0.489 0.214 Input Power (W)50.1 49.5 54.6 53.7 58.4 57.4 In-rush (A) 3.1 15 3.2 14.8 3.4 14.8 Inrush duration (µs)202 117 196 131 192 121 THD (%)5.5 7.6 7 7.2 8.1 7.2 PF ≥ 0.99 ≥ 0.96 ≥ 0.99 ≥ 0.96 ≥ 0.99 ≥ 0.97 ENERGY DATA TM-30-15 Rf = 86 Rg = 95.5 CRI/CIE Ra = 83.8 R9 = 10.3 TM-30-15 Rf = 91.1 Rg = 99 CRI/CIE Ra = 92.4 R9 = 55.1 Reference Illuminant Reference IlluminantTest Source Test Source * Color values are based on 61WDWB reflector, other finishes and field results may vary. HC6 | HM6 | 61 | 61PS PS517016EN page 8 November 8, 2023 3:26 PM NEW CONSTRUCTION - MID LUMEN3000 AND 4000 LUMEN NEW CONSTRUCTION - HIGH LUMEN4500 – 6000 LUMEN .5" [12.70mm](ceiling thickness) 6.06" [153.92mm](reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) max module height(see table) LED height(see table)3.42"[86.77mm](driver height) .5" [12.70mm](ceiling thickness) 6.05" [153.72mm](reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) max module height(see table) LED height(see table)3.42"[86.77mm](driver height) 6.06" [153.92mm](reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) LED height(see table) max moduleheight(see table) .5"[12.70mm](ceiling thickness) NEW CONSTRUCTION - LOW LUMEN500 – 2500 LUMENS 4.2"[107.34mm]hanger bar bracketheight (removable) 3.42" [86.77mm](driver height) 8.6"[217.35mm] 26.4"[670.56mm] Dimensional and Mounting Details NEW CONSTRUCTIONS - LOW LUMEN 500 – 2500 LUMENS NEW CONSTRUCTIONS - MID LUMEN 3000 – 4000 LUMENS NEW CONSTRUCTIONS - HIGH LUMEN 4500 – 6000 LUMENS Mid Lumen (3000 – 4000 Lumens) Distribution Max. Module Height Trim Height LED Height Narrow 6.6"3.4”3.8” Medium 6.7”3.5”3.9” Wide 6.5”3.3”3.7” Baffle 6.5”3.3”3.7” High Lumen (4500 – 6000 Lumens) Distribution Max. Module Height Trim Height LED Height Narrow 6.9"3.4”3.8” Medium 7.0”3.5”3.9” Wide 6.8”3.3”3.7” Baffle 6.8”3.3”3.7” Low Lumen (500 – 2500 Lumens)* Distribution Max. Module Height Trim Height LED Height Narrow 4.5"3.4”3.8” Medium 4.6”3.5”3.9” Wide 4.4”3.3”3.7” Baffle 4.4”3.3”3.7” *Max. height w/removable hanger bar bracket 4.2” NEW CONSTRUCTION - MID LUMEN3000 AND 4000 LUMEN NEW CONSTRUCTION - HIGH LUMEN4500 – 6000 LUMEN .5"[12.70mm](ceiling thickness) 6.06" [153.92mm](reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm](trim flange) trim height (see table) max module height(see table) LED height(see table)3.42"[86.77mm] (driver height) .5"[12.70mm](ceiling thickness) 6.05" [153.72mm](reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm](trim flange) trim height (see table) max module height(see table) LED height(see table)3.42"[86.77mm] (driver height) 6.06" [153.92mm](reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm](trim flange) trim height (see table) LED height (see table) max moduleheight(see table) .5"[12.70mm](ceiling thickness) NEW CONSTRUCTION - LOW LUMEN500 – 2500 LUMENS 4.2"[107.34mm] hanger bar bracketheight (removable) 3.42"[86.77mm](driver height) 8.6" [217.35mm] 26.4" [670.56mm] NEW CONSTRUCTION - MID LUMEN3000 AND 4000 LUMEN NEW CONSTRUCTION - HIGH LUMEN4500 – 6000 LUMEN .5"[12.70mm](ceiling thickness) 6.06" [153.92mm] (reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) max module height(see table) LED height(see table)3.42"[86.77mm](driver height) .5"[12.70mm](ceiling thickness) 6.05" [153.72mm] (reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) max module height(see table) LED height(see table)3.42"[86.77mm](driver height) 6.06" [153.92mm] (reflector inner aperture) 7.25" [184.15mm](ceiling cut out) 7.75" [196.85mm](trim flange) trim height(see table) LED height(see table) max moduleheight(see table) .5" [12.70mm](ceiling thickness) NEW CONSTRUCTION - LOW LUMEN500 – 2500 LUMENS 4.2"[107.34mm]hanger bar bracketheight (removable) 3.42"[86.77mm](driver height) 8.6"[217.35mm] 26.4"[670.56mm]Mid Lumen Module High Lumen Module Low Lumen Module HC6 | HM6 | 61 | 61PS PS517016EN page 9 November 8, 2023 3:26 PM Connected Solutions WaveLinx LITE - WTK Tilemount Sensor WaveLinx PRO – WTA Tilemount Sensor • Intuitive Android™ or Apple® iOS® app for basic system code compliant set up and configuration via Bluetooth • Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network) • Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes • Automatic occupancy or vacancy, sensor sensitivity, daylight dimming, etc. configurable through the app • Refer to the WaveLinx system specifications for details • WaveLinx PRO tilemount functionality configures zones and customizes settings from one secure mobile app • Automatic code commissioning that meets the strictest codes • Fixtures and sensors integrate with Wireless Area Controller, Wall Stations, and Control Devices • Stand-Alone Offices or Entire Building Network Installations +++ WaveLinx Area Controller Provides centralized coordination of multiple area control options Mobile Applications Provides personalized, local control from a tabletor smartphone Wireless Wall Station/Receptacle Provides customized wireless control of each area Downlights with tilemount sensor wireless communication Highly efficient LED fixtures WaveLinx mobile app settings WaveLinx CORE Building Management IntegrationWaveLinx WTA Tilemount Wiring Diagram WaveLinx LITE WTK Tilemount Wiring Diagram WaveLinx LITE Bluetooth Enabled System ManualDimmer OccupancySensor Lumen MaintenanceControl DaylightingControl Manually SwitchedON/OFF DemandResponseTuningControlSchedulingReceptacleControl WaveLinxTilemount Sensor Kit control module(MSP3IVMVDC1EP)(included) 54” Plenum cable(5140-000123-00)(included) 120-277 VAC 3A downlights with 0-10V control WaveLinx Sensor and Mounting Trim (included) Includes switchleg (Blue load out wire) and 0-10V to each fixture controlled ceiling tileceiling tile WaveLinx LITETilemount Sensor Kit control module(MSP3IVMVDC1EP)(included) 54” Plenum cable(5140-000123-00)(included) 120-277 VAC 3A downlights with 0-10V control WaveLinx LITE Sensor and Mounting Trim (included) Includes switchleg (Blue load out wire) and 0-10V to each fixture controlled ceiling tileceiling tile ceiling cutaway view WaveLinx LITETilemount Sensor Kit WaveLinx LITEIntegrated IndustrialWaveLinx LITEAmbient WaveLinx LITEIntegrated Parking Garage WaveLinx LITEWallstationWaveLinx LITEIntegrated Ambient WaveLinx LITEMobile Application MyAppsSecure PortalSite Initiation, Data Backup & Site Transfer Area or Room(49 + 1 construction area) Area or Room(49 + 1 construction area) Wi-Fi Signal IEEE 802.15.4 KEY Building LAN Touchscreen PoEPower WaveLinx COREBACnet/IPPublic (REST) API Third Party system (hardware provided by others)BACnet Router1 (hardware provided by others) Desktop/Laptopwith web browser (hardware provided by user) Note:Performance based on second generation WaveLinx Area Controller (WAC2). WaveLinx CORE Pro shown in this illustration. WaveLinx CORE hardware can be either Pro, Enterprise or Virtual. 1 BACnet Router only required if WaveLinx CORE and third party BACnet client are on different subnets. Smartphone with WaveLinx appused for system setup and personal control WaveLinx PRO controlled devices(up to 200 devices per WAC2 - 150 devices best practice) - see Note WaveLinxAreaController PRO OccupancyCeiling Sensor PRO ControlledReceptacle PRO Wallstation WaveLinx PRO enabled Indoor Fixture120-347V 20A PRO Dimming Switchpacks WaveLinx PRO enabled Outdoor Fixture Area or Room(49 + 1 construction area) ScenesManualDimmerOccupancySensorLumen MaintenanceControlDaylightingControlManually SwitchedON/OFFDeviceSecurity TuningControl 120-277VAC Black (Hot) White (Neutral) Purple (Dimming) White (Neutral) Blue (Not Switched) Pink (Dimming) Control module(MSP3IVMVDC1EP)0-10VDImming Driver 120-277VAC Black (Hot) White (Neutral) Purple (Dimming) White (Neutral) Blue (Not Switched) Pink (Dimming) Control module(MSP3IVMVDC1EP)0-10VDImming Driver HC6 | HM6 | 61 | 61PS PS517016EN page 10 November 8, 2023 3:26 PM Cooper Lighting Solutions1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.cooperlighting.com © 2023 Cooper Lighting SolutionsAll Rights Reserved. Specifications and dimensions subject to change without notice. PS517016EN page 11 November 8, 2023 3:26 PM HC6 | HM6 | 61 | 61PS 120-277 VAC 3A downlights with 0-10V control WPN D010 White (AC-N) Black (AC-L) Grey (GND) Red (LED+) Purp l e (Dim+) Pink (Dim-) Blue (LED-) Yellow (Au x -) Grey(Aux-) Green(GND) Connected Solutions WaveLinx PRO Wireless Node - WPN Building LAN Wireless AreaController Touchscreen WaveLinx Mobile Appused for system setup and personal control PoEPower Trellix CoreBACnet/IPPublic (REST) API Third Party system (hardware provided by others)BACnet Router1 (hardware provided by others) Desktop/Laptopwith web browser (hardware provided by user) • WaveLinx Wireless functionality configures zones and customizes settings from one secure mobile app • Automatic code commissioning that meets the strictest codes • Fixtures and sensors integrate with WaveLinx Area Controller, Wall Stations, and Control Devices • Stand-Alone Offices or Entire Building Network Installations +++ WaveLinx Area Controller Provides centralized coordination of multiple area control options Mobile Applications Provides personalized, local control from a tablet or smartphone Wireless Wall Station/Receptacle Provides customized wireless control of each area Downlights with wireless communication Highly efficient LED fixtures WaveLinx mobile app settings WaveLinx CORE Building Management IntegrationWaveLinx PRO Wireless Node (WPN) Wiring Diagram ManualDimmer OccupancySensor Lumen MaintenanceControl DaylightingControl Manually SwitchedON/OFF DemandResponseTuningControlSchedulingReceptacleControl