HomeMy WebLinkAboutMP-24-02 - Supplemental - 0200 da Vinci Drive (2)355 Main Street | Suite 500 | Winooski, VT 05404 | w. eivtech.com
May 1, 2024
Marla Keene, PE
Development Review Planner
City of South Burlington
180 Market Street
South Burlington, VT 05403
Re: Burlington International Airport
Burlington School District’s Aviation Technical Center Project
Master Plan and Site Plan Review Application
Dear Marla Keene,
Thank you for your time to review our concurrent master plan and site plan application for the above reference project.
We have included the list of application requirements, and our team’s response to where this information is now
included in the chart below. Updated plansheets and exhibits have been included in our file transfer folder with the
revision date in the file name.
Master Plan Application Requirement City Comments Design Team Response
Location of existing restrictions on land, such as
easements and covenants.
I believe there are stormwater
easements & a ROW that has
been offered to the City. There
may be others?
The overall sketch plan has
been updated to include all
existing restrictions on land.
A complete survey of the subdivision, prepared
by a licensed land surveyor, showing the
location, bearing and length of every street line,
lot line and boundary line, and existing and
proposed restrictions on the land, including but
not limited to access ways and utility
easements. Where applicable, this information
shall be tied to reference points previously
established by the City.
Since you are not proposing a
subdivision, this is largely the
same as the above
The overall sketch plan has
been updated to include all
existing restrictions on land.
355 Main Street | Suite 500 | Winooski, VT 05404 | w. eivtech.com
Master Plan Application Requirement City Comments
Existing water courses & buffers, wetlands &
buffers, base flood elevations if located in an
area of special flood hazard, wooded areas,
ledge outcrops, and other natural features.
The buffer for the
wetland to the south may
encroach into the project
area. Please show.
The maximum number of vehicle trip ends
(VTEs) and associated parking proposed for
the property or properties subject to the
master plan.
The actual trip generation
is omitted from the memo
Site Plan Application Requirement City Comments
Location of existing restrictions on land,
such as easements and covenants.
Maybe nothing on the
actual site, but since these
are the same plans as for
the MP, please update as
well
Location of planned restrictions on land,
such as easements and covenants.
I assume there is a new
easement on the Beta MP
area proposed to support
this project?
The location of any outdoor storage for
equipment and materials if any, and the
location, type and design of all solid
waste-related facilities, including dumpsters
and recycling bins.
Where will dumpsters /
waste disposal be for this
project?
Design Team Response
Wetland areas and their buffers will
not be impacted by this
project. The distance from the top
of the bank to the nearest project
disturbance is 79 feet. This
dimension has been added to
the Grading Drainage Plan, GR-01.
The traffic memo was updated
to include trip generation details.
Design Team Response
The overall sketch plan has been
updated to include all existing
restrictions on land.
The overall sketch plan has been
updated to include all existing
restrictions on land.
The Site Plan, SP-01, has been
updated to label the location of the
dumpsters/waste disposal for this
project. In addition to the dumpster
area, the revised site plan has the
snow storage area labeled.
355 Main Street | Suite 500 | Winooski, VT 05404 | w. eivtech.com
Site Plan Application Requirement City Comments
Existing water courses & buffers, wetlands & buffers,
base flood elevations if located in an area of special
flood hazard, wooded areas, ledge outcrops, and other
natural features.
Same as for MP, please
show wetland buffer and
how it relates to project
area
A list of existing vegetation, with the location, type, and
size of existing trees of six inches or greater in caliper.
Existing veg is shown but
labels are omitted
A written plan to preserve and protect significant
existing vegetation during and after construction. Such
plan will be of sufficient detail that the City of South
Burlington will be able to inspect the site during
construction to ensure that existing vegetation is
protected as per the plan.
It doesn’t appear you’re
proposing to protect
existing veg. This may
benefit from some
narrative, because I see
you are providing some
plantings.
Detailed landscaping plan, specification of materials,
costs, and phasing plan, including vegetation to remain,
types of new plant materials, identified by common
name and botanical name, sizes of all new plant
materials by height and/or diameter at time of planting
and at maturity, quantities of each of the planting
materials, and treatment of the ground surface (paving,
seeding, or groundcover) for all plantings, screening,
buffering, and stormwater infiltration.
Budget omitted
Design Team Response
Wetland areas and their buffers
will not be impacted as part of
this project. The distance from
the top of the bank to the
nearest project disturbance is
79 feet. This dimension has
been added to the Grading
and Drainage Plan, GR-01.
EX-01 has been updated to label
these trees as being removed.
This is the only vegetation within
the project disturbance limits.
EX-01 has been updated to label
these trees as being removed.
This is the only vegetation within
the project disturbance limits.
The landscaping budget for the
project is approximately
$50,000. The existing vegetation
will be removed and new
vegetation will be planted as
shown on sheet LL-02, Lighting
and Landscaping Plan. This
plansheet includes a planting
schedule and details.
355 Main Street | Suite 500 | Winooski, VT 05404 | w. eivtech.com
Feel free to contact Larry Lackey, or Jacqueline Dagesse at EIV with any questions regarding this submission,
802-324-5522.
Very Respectfully,
EIV Technical Services
Jacqueline Dagesse, MBA, CPESC
President / Environmental Engineer
Site Plan Application Requirement City Comments Design Team Response
One set of preliminary plans, elevations, floor plans,
and sections of proposed structures showing the
proposed location, use, design and height of all
structures, roads, parking areas, access points, sidewalks
and other walkways, loading docks, outdoor storage
areas, sewage disposal areas, landscaping, screening,
site grading, and recreation areas if required. Plans shall
also show any proposed division of buildings into units
of separate occupancy and location of drives and access
thereto.
Dumpster area? Snow
storage?
The Site Plan, SP-01, has been
updated to label the location of
the dumpsters/waste disposal for
this project. In addition to the
dumpster area, the revised site
plan has the snow storage area
labeled.
Analysis of traffic impacts, if required by the traffic
overlay district and/or the DRB.
# of trips omitted The traffic memo was updated to
include trip generation details.
355 Main Street | Suite 500 | Winooski, VT 05404 | w. eivtech.com
Photo 1: Existing conditions at the front of the existing hangar.
Photo 2: Existing conditions of the parking lot.