Loading...
HomeMy WebLinkAboutSP-24-20 - Supplemental - 0200 da Vinci DriveCITY OF SOUTH BURLINGTON DEVELOPMENT REVIEW BOARD SP-24-20_200 Davinci Dr_BSD Aviation Tech_2024-06- 04 DEPARTMENT OF PLANNING & ZONING Report preparation date: May 29, 2024 Plans received: May 1, 2024 200 da Vinci Drive – Burlington School District Site Plan Application #SP-24-20 Meeting date: June 4, 2024 Owner City of Burlington Patrick Leahy Burlington International Airport 1200 Airport Drive South Burlington, VT 05403 Applicant Tom Flanagan, Burlington School District Superintendent 150 Colchester Avenue Burlington, VT 05401 Property Information Tax Parcel ID: 2000-00000 Airport Industrial Zoning District Engineer McFarland Johnson 426 Industrial Avenue, Suite 146 Williston, VT 05495 Location Map #SP-24-20 2 PROJECT DESCRPTION Site plan application #SP-24-20 of Burlington School District to amend a previously approved plan for an airport complex. The amendment consists of renovating an existing hangar for the use of Burlington School District’s Aviation Technical Center, including reconfiguration of the parking and site circulation, 200 Davinci Drive CONTEXT The project area is at the south end of the airport property immediately adjacent to the recently approved Beta manufacturing facility on Davinci Drive. The project involves lands within the airport PUD as well as within the Beta Master Plan area. Therefore the project is being considered in two parts. The subject application is a site plan for the portion of the project located within the airport PUD. The application has also submitted a minor Master Plan amendment application for the portion of the project within the Beta Master Plan Area, which will be reviewed by the Board on June 18, 2024. The proposed changes consist of installation of a significant amount of doors and windows on the existing building façade, removal of a smaller number of doors, interior renovation, and modifications to the site access and circulation at the south end of the site. COMMENTS Development Review Planner Marla Keene and Director of Planning and Zoning Paul Conner (‘Planning Staff’) have reviewed the plans submitted on 5/1/2024 and offer the following comments. Numbered comments for the Board’s attention are indicated in red. A) ZONING DISTRICT & DIMENSIONAL REQUIREMENTS Airport Industrial Zoning District (AIR-I) Required Proposed Min. Lot Size 3 acres No change Max. Building Coverage 30% No change Max. Overall Coverage 50% 36.5% Max Front Setback Coverage 30% Unknown Max Front Setback 50 ft. No change Min. Side Setback 35 ft. No change Min. Rear Setback 50 ft. No change  Building Height (flat roof) 35 ft. No change  Meets requirement Airport Industrial Zoning District The purpose of the Airport Industrial Zoning District is to provide sufficient land area for Airport- related uses, support facilities, and commercial activities that may be incompatible with general residential or commercial uses. The standards and regulations for the Airport Industrial District recognize the importance of these facilities and uses to the operation of the City and regional #SP-24-20 3 economies while providing appropriate setbacks and buffering to offset their impacts on adjacent land uses. Applications involving new or expanded buildings within the AIR-I district must comply with the regulations pertaining to airport approach cones. No building construction or expansion is proposed. B) SITE PLAN REVIEW STANDARDS 14.06 General Review Standards A. Relationship of Proposed Structures to the Site. (1) The site shall be planned to accomplish a desirable transition from structure to site, from structure to structure, and to provide for adequate planting, safe pedestrian movement, and adequate parking areas. Staff considers the applicant is proposing to improve the street presence of the structure by adding glazing to the street facing and side facades. The applicant is proposing to add a flush pedestrian walkway from the proposed expanded parking area west of the building to the improved main entrance. 1. There is no safe pedestrian access to the building from Davinci Drive either existing or proposed, though there is a sidewalk along Davinci Drive. Given the proposed use of the building for students, and the City’s prioritization of personal mobility (ie biking and walking), Staff recommends the Board discuss with the applicant how to improve access to the site for users that are not arriving in cars or buses. Adequacy of planting is discussed elsewhere in this document. (2) Parking: (a) Parking shall be located to the rear or sides of buildings. Any side of a building facing a public street shall be considered a front side of a building for the purposes of this subsection. (b) The Development Review Board may approve parking between a public street and one or more buildings if the Board finds that one or more of the following criteria are met. The Board shall approve only the minimum necessary to overcome the conditions below. (viii) The building, or a portion thereof, being served by the parking area is contained within the Security Identification Display Area of a publicly-owned and operated airport. Staff considers that the front side of this building is Davinci Drive, since the City has an irrevocable offer of dedication for the street. The applicant is proposing to reconfigure and expand existing parking areas to the front of the adjacent hangar buildings to the west. Those buildings are not the subject of this application, though they and the subject buildings are within the airport security fence. 2. Staff recommends the Board ask the applicant to demonstrate that the parking is the minimum necessary and discuss whether they will allow this exemption for parking. (3) Without restricting the permissible limits of the applicable zoning district, the height and scale of each building shall be compatible with its site and existing or anticipated adjoining buildings. #SP-24-20 4 No changes to the height of the building are proposed. The applicant is proposing to add a canopy at the new main entrance to the building, but the canopy will be contained within the width and height of the existing building. B. Relationship of Structures and Site to Adjoining Area. (1) The Development Review Board shall encourage the use of a combination of common materials and architectural characteristics (e.g., rhythm, color, texture, form or detailing), landscaping, buffers, screens and visual interruptions to create attractive transitions between buildings of different architectural styles. Staff comments pertaining to buffering and screening are included in 14.07 below. The applicant is proposing to paint the building but otherwise not to modify the materials of the building. (2) Proposed structures shall be related harmoniously to themselves, the terrain and to existing buildings and roads in the vicinity that have a visual relationship to the proposed structures. Staff considers the proposed modifications to the structure to be sufficiently related to setting given the magnitude of the modifications. (3) To accomplish (1) and (2), the DRB shall consider: (a) Pattern and Rhythm. Update or maintain or extend the overall pattern of development defined by the planned or existing street grid, block configurations, position and orientation of principal buildings, prevalence of attached or detached building types. No modifications affecting compliance with this standard are proposed. (b) Architectural Features. Respond to recurring or representative architectural features that define neighborhood character, without adhering to a particular architectural style. The proposed modification to architectural features include addition of an entrance canopy and glazing. (c) Privacy. Limit impacts and intrusions to privacy on adjoining properties, including side and back yard areas through context sensitive design. No changes to privacy of adjoining properties are proposed. C. Site Amenity Requirement This criterion is only applicable to expansions and new residential conversions. 14.07 Specific Review Standards In all Zoning Districts and the City Center Form Based Codes District, the following standards shall apply: A. Environmental Protection Standards. All proposed development shall be subject to the applicable requirements of Article 12, Environmental Protection Standards. There are no impacts to resources considered in Article 12 proposed as part of this project. B. Site Design Features. All proposed development shall comply with standards for the placement of buildings, parking and loading areas, landscaping and screening, open space, #SP-24-20 5 stormwater, lighting, and other applicable standards related to site design pursuant to these Land Development Regulations. These standards are contained in Article 13 and are discussed below. C. Access and Circulation. All proposed development shall comply with site access and circulation standards of Section 15.A.14. The applicant is proposing to modify the access and circulation in front of the existing hangars to the west of the subject building by formalizing one parking area, expanding another, and realigning and widening the driveway at the east end of the parking areas. They are not proposing modifications to the access and circulation in front of the subject building. Relevant standards of 15.A.14 include those pertaining to safe pedestrian access and to minimizing curb cuts by providing shared vehicular access. Davinci Drive is not currently a public street, but there is an irrevocable offer of dedication to the City therefore it should be treated as a public street for the purposes of layout and design. 3. Staff recommends the Board ask the applicant to demonstrate that the proposed pavement is minimized near the entrance to Davinci Drive. Too wide open a pavement area with multiple (four in this case) non-perpendicular locations for cars to come from can lead to safety issues. The driveway at the west end is narrow, so it does not appear this area is needed for large vehicle circulation. D. Transportation Demand Management (TDM) [reserved] E. Building Form. Development within the City Center Form Based Code District, the Urban Design Overlay District, and other districts with supplemental building form standards shall adhere to the standards contained therein. Not applicable. F. Streetscape Improvements. A proposed new construction or extension/expansion of an existing structure exceeding the thresholds listed in either (a) Section 14.09(B) or (b) Section 8.11(D) within the City Center Form Based Code, or Section 3.11(D) in all other zoning districts, shall be required to upgrade adjacent sidewalks, greenbelts, and related street furniture (trees, benches, etc.) to the standards contained within the applicable Street Type and Building Envelope Standard. Nothing in this subsection shall be construed to limit requirements for additional upgrades as necessary to meet the requirements of these Regulations. Staff considers no upgrades to be required. G. Access to Abutting Properties. The reservation of land may be required on any lot for provision of access to abutting properties whenever such access is deemed necessary to reduce curb cuts onto an arterial or collector street, to provide additional access for emergency or other purposes, or to improve general access and circulation in the area. 13.02F requires driveway connections between adjacent commercial lots. The airport is generally one large lot. Driveway connections between buildings are generally provided and not reduced by this application. H. Utility Services. Electric, telephone and other wire-served utility lines and service connections shall be underground insofar as feasible and subject to state public utilities regulations. Any utility installations remaining above ground shall be located so as to have a harmonious relation to neighboring properties and to the site. Standards of Section 15.A.18, Infrastructure, Utilities, and Services, shall also be met. #SP-24-20 6 The property is currently served by overhead utilities. The applicant is proposing to remove the existing transformer at the building, but it is unclear how the utilities are proposed to be routed to the replacement transformer. 4. Staff recommends the Board ask the applicant to explain at what point the existing overhead utilities will be located underground, and consider requiring the utilities to be located underground at the upstream most pole that is impacted by the work. The South Burlington Director of Public Works reviewed the plans on 5/23/2024 and offers the following comments:  The applicant will need to work with the wastewater superintendent to confirm that the project has a sufficient wastewater allocation for the change in use.  The wastewater pump station will remain privately owned.  Does the property have an existing oil / water / grease / grit separator? Will the change in use require that one be installed?  Are any water (or other) easements proposed to be transferred to the City? 5. Staff recommends the Board ask the applicant to verbally answer the questions of the Director of Public Works and include conditions for any necessary modifications. I. Disposal of Wastes. All dumpsters and other facilities to handle solid waste, including compliance with any recycling, composting, or other requirements, shall be accessible, secure and properly screened with opaque fencing to ensure that trash and debris do not escape the enclosure(s). Small receptacles intended for use by households or the public (ie, non-dumpster, non-large drum) shall not be required to be fenced or screened. There are no proposed changes to the location or screening of the existing dumpster, which meets this criterion. C) SUPPLEMENTAL REGULATIONS 13.02 Off Street Parking and Loading G. Design requirements for Parking Spaces, Parking Aisles, Lighting and Landscaping (1) Design requirements for off-street parking and loading are provided in Table 13-2 and Figure 13-1, Section 13.04, Landscaping , Screening, and Street Trees, and Section 13.07, Exterior Lighting. All paved parking spaces shall be striped or otherwise physically delimited. Sections 13.04 and 13.07 are discussed below. Parking is proposed to meet the required dimensional standards. (2) The location of parking areas and loading docks shall prevent conflicts with entering and existing traffic onto a public street and prevent conflicts between vehicles and pedestrians. The distance between access points and parking areas shall be adequate to minimize blockage and prevent back-ups onto the public street. Staff considers this criterion met. (3) Provision shall be made for access by police, fire and emergency vehicles. The Fire Marshal reviewed the project on 5/22/2024 and indicated there were no comments pertaining to the Development Review Board’s review of the project. #SP-24-20 7 (4) Pedestrian safety. Insofar as practicable, pedestrian and bicycle circulation shall be separated from motor vehicle circulation. Safe and convenient pedestrian circulation, including appropriate sidewalks, shall be provided on the site and its approaches. The pedestrian circulation on site shall be designed to minimize adverse effects of vehicular traffic on sidewalks and recreation paths. 6. The applicant is proposing an on-grade striped pathway from the parking area to the building. Staff recommends the Board consider requiring the pathway to be raised by a curb and consider requiring a sidewalk connection and crosswalk to Davinci Drive, as alluded to above. (5) Bicycle parking or storage facility. Bicycle parking is discussed under 13.03 below. (6) Stormwater management strategies that facilitate infiltration including but not limited to recessed planting islands, bioretention facilities, and pervious parking spaces are encouraged in the design of any off-street parking or loading area. The applicant is proposing a bioretention area between the two sections of parking lot. Infiltration is not proposed. Stormwater management is discussed under 13.05 below. 13.03 Bicycle Parking and Storage. 7. The building is 34,445 sf and is proposed to be used by 12 employees and 100 students. One short term space is required for each 20 students of planned capacity, or five spaces. It does not appear the applicant has proposed any bicycle parking. Staff recommends the Board require the applicant to add short term bicycle parking to the plan proximate to a student entrance. As an existing building, long-term bicycle parking requirements do not apply. 13.04 Landscaping, Screening & Street Trees B. Except for parking spaces accessory to a one-family or two-family dwelling, all off-street parking areas subject to review by the Development Review Board shall be curbed and landscaped with appropriate trees, shrubs, and other plants including ground covers, as approved by the Development Review Board. Sections of recessed curb are permitted if their purpose is to allow stormwater runoff from the adjacent parking area to reach stormwater collection, treatment and management infrastructure. The Development Review Board shall consider the adequacy of the proposed landscaping to assure the establishment of a safe, convenient, and attractive parking area and the privacy and comfort of abutting properties. The applicant is proposing to reconfigure and add parking so that there are 68 parking spaces west of the building. Staff considers these standards apply to those 68 spaces. (1) All off-street parking areas shall be landscaped around the perimeter of the lot with trees, shrubs and other plants. Perimeter planting shall be set back from the curb sufficiently to allow for snow storage. The purpose of perimeter planting shall be to mitigate the view of the parking lot from the public way and from adjacent uses and properties, and to provide shade and canopy for the parking lot. In some situations it may be necessary, both for surveillance purposes and for the perception of safety, to install the #SP-24-20 8 size and type of plants that leave visual access between the parking lot to the public way or other pedestrian areas. 8. No parking lot landscaping is proposed. Staff recommends the Board require the applicant to revise their plans to provide landscaping to screen the proposed and reconfigured parking from the future public street. (2) In all parking areas containing twenty-eight (28) or more contiguous parking spaces and/or in parking lots with more than a single circulation lane, at least ten percent (10%) of the interior of the parking lot shall be landscaped islands planted with trees, shrubs and other plants. Such requirement shall not apply to structured parking or below- ground parking. 9. Staff recommends the Board require the applicant to demonstrate compliance with this criterion by providing a figure showing the parking area and the fraction landscaped. (3) All interior and perimeter planting shall be protected by curbing unless specifically designed as a collection and treatment area for management of stormwater runoff as per 13.04(B)(5)(c) below. Interior planted islands shall have a minimum dimension of six (6) feet on any one side, and shall have a minimum square footage of sixty (60) square feet. Large islands are encouraged. 10. No curbing is proposed. Staff considers curbing will be required to protect adjacent landscaping except where the adjacent area is specifically designed as a stormwater collection or treatment area. (4) Landscaping Requirements (a) Landscaping shall include a variety of trees, shrubs, grasses and ground covers. All planting shall be species hardy for the region and, if located in areas receiving road runoff or salt spray, shall be salt-tolerant. (b) At least one (1) major deciduous shade tree shall be provided within or near the perimeter of each parking area, for every five (5) parking spaces. The trees shall be placed evenly throughout the parking lot to provide shade and reduce glare. Trees shall be placed a minimum of thirty (30) feet apart. (c) Trees shall have a caliper equal to or greater than two and one-half (2 ½) inches when measured on the tree stem, six (6) inches above the root ball. (d) Where more than ten (10) trees are installed, a mix of species is encouraged; the species should be grouped or located in a manner that reinforces the design and layout of the parking lot and the site. These criteria apply to parking lot landscaping and should be used in designing the proposed landscaping for the revised and expanded parking lot. (e) Within the City Center FBC District, landscaping required within this section shall not count towards meeting minimum landscape budget requirements as detailed in Section 13.04(G). Not applicable. (7) Snow storage areas must be specified and located in an area that minimizes the potential for erosion and contaminated runoff into any adjacent or nearby surface waters. Snow storage areas have been specified. Staff considers this criterion met. #SP-24-20 9 C. Screening or buffering. The Development Review Board will require landscaping, fencing, land shaping and/or screening along property boundaries (lot lines) whenever it determines that a) two adjacent sites are dissimilar and should be screened or buffered from each other, or b) a property’s appearance should be improved, which property is covered excessively with pavement or structures or is otherwise insufficiently landscaped, or c) a commercial, industrial, and multi- family use abuts a residential district or institutional use, or (d) a parking or loading area is adjacent to or visible from a public street. (1) There shall be sufficient landscaping, walls, or fencing of sufficient height (minimum of three (3) feet) and opacity to effectively screen the parking or loading area year-round from adjacent public streets. (2) Screening of a parking or loading shall be provided where headlights from vehicles on site may be visible and project parallel to a public street. These two criteria should be taken into considering in the design of the parking lot landscaping. (3) There shall be sufficient landscaping, walls, or fencing of sufficient height and opacity to effectively screen outdoor storage areas, refuse, recycling, and compost collection (excluding on-site composting) areas. Staff considers no additional outdoor storage screening to be necessary. (4) The landscaping shall be designed to minimize erosion and stormwater runoff, and to protect neighboring residential properties from the view of uses and parking areas on the site. The landscaping shall be of such type, height, and spacing, as in the judgment of the Development Review Board, will effectively screen the activities on the lot from the view of persons standing on adjoining properties. The plan and specifications for such planting shall be filed with the approved plan for the use of the lot This criterion should be taken into considering in the design of the parking lot landscaping. G(3) Landscaping Budget Requirements. There is no minimum landscaping budget because no building addition is proposed. I. Landscape Maintenance. Maintenance and responsibility. All planting shown on an approved site plan shall be maintained by the property owner in a vigorous growing condition throughout the duration of the use. Plants not so maintained shall be replaced with new plants at the beginning of the next immediately following growing season. Trees with a caliper of less than 5” may be replaced on an inch-by-inch basis with trees of the same genus of at least 2” caliper each. No permit shall be required for such replacements provided they conform to the approved site plan. Replacement of trees with a caliper of greater than 5” shall require an amendment to the site plan. The applicant is proposing to remove four (4) 8 to 10-inch caliper trees from the front of the building. The applicant is proposing to plant seven shrubs and 32 ornamental grasses. 11. While Staff considers the proposed plantings to not be sufficient replacement for the removed trees, as described above, the applicant must also provide parking lot landscaping, including shade trees. Staff considers the combined resulting planting likely to be adequate to replace the removed trees, and recommends the Board confirm once the proposed parking lot planting plan is complete. 13.05 Stormwater Management #SP-24-20 10 Stormwater standards apply when one-half acre or more of impervious surface exists or is proposed to exist, and where 5,000 sf of impervious is created or reconstructed. At the time of this writing, Staff had not yet received comments from the City Stormwater section. 12. Staff recommends the Board provide Staff an opportunity to provide an update at the time of the hearing. 13.06 Airport Approach Cones All applications for development within the Airport Approach Cones, as shown on the Overlay Districts Map, involving new or expanded buildings or structures shall provide documentation that either a Notice to the Federal Aviation Authority (FAA) is not required, or an application for a Determination of No Hazard has been submitted to the FAA. Where an application for Determination of No Hazard has been submitted, no zoning permit for construction shall be issued without demonstration of receipt of an issued Determination. 13. Staff recommends the Board require the applicant to demonstrate submission of an application for Determination of No Hazard, and condition the approval on receipt of an issued determination. 13.07 Exterior Lighting Lighting requirements are summarized as follows. (1) Fixtures must be downcast and shielded (2) Illumination must be evenly distributed (3) Fixtures must be placed to minimize lighting from becoming a nuisance (4) Poles shall be rustproof metal, cast iron, fiberglass, finished wood or similar structural material, with a decorative surface or finish (5) Poles & building mounted fixtures may be no higher than 30-ft (6) Poles must be located in safe locations Specific requirements for maximum illumination levels are included in Appendix A and are limited to 3-foot candles average at ground level. The applicant has provided a photometric drawing but has not indicated an average illumination level, though Staff considers it is likely to be below 3 foot candles. 14. Staff notes there is one “hotspot” of 15 footcandles near the eastern entrance of the building and recommends the Board discuss whether to direct the applicant to reconfigure the proposed lighting to reduce this hotspot to on the order of 8 – 10 footcandles. 13.11 Fences The applicant has proposed to relocate 75 ft of airport security fence as part of this project. The Board has typically considered airport security fence exempt from local regulation under 24 VSA 4413, and Staff recommends the Board do the same here. 13.12 Utility Cabinets and Similar Structures #SP-24-20 11 B. Specific Standards for Utility Cabinets and Similar Structures. (4) There shall be sufficient landscaping or fencing of sufficient height and opacity to screen effectively the facility year-round from streets and abutting unaffiliated properties. 15. Screening is proposed for the proposed generator but not for the proposed utility transformer. Staff recommends the Board ask the applicant to describe the proposed height of the generator in order to determine if screening is adequate. 16. Staff recommends the Board require the applicant to provide screening of sufficient height to screen the transformer from the street. (5) The location of the facility shall be shown on all relevant site plans. (6) Utility cabinets and similar structures shall be located a minimum of five (5) feet from all existing or planned public roads or rights-of-way. Staff considers criterion #5 and 6 to be met. RECOMMENDATION Staff recommends that the Board work with the applicant to address the issues identified herein. The related master plan application is scheduled to be reviewed on June 18. Staff considers if the applicant can provide the required information prior to concluding the hearing on June 4 that the Board may continue to June 18 and Staff will incorporate review of the revised materials into the June 18 packet. Respectfully submitted, Marla Keene, Development Review Planner