Loading...
HomeMy WebLinkAboutBATCH - Supplemental - 1068 Williston Road (2)Allen, Jr ,man man of the Board E O'Hara dent,.. im P. Steele or Vice President rt A. Elder utive Vice President N. Stokes 0 President and General Counsel ALLEN BROS. & O'HARA, INC. /0 y ryP n D. Smith resident NATIONWIDE GENERAL CONTRACTORS ris L. Seutel t President ick J. Jensen 3742 LAMAH AVE. MEMPHIS 18, TENNESSEE TELEPHONE 363-1511 retary -Treasurer C,ict4ber 12, 1964 State of Vermont Department of Public Safety Dire Prevention uivision Montpelier, Vermont Attention: Lt. Lloyd E. Howard Gentlemen: Re: Holiday Inn Seth Burlington, Ver,-;nwnt Job No. 1847 You will kindly consider this as formal acknowledgement of your letters of June 10, 1964, July 15, 1964, August S, 1964, September 30, 1964 and October 5, 1964, written with reference to the above subject. You -,xill kindly further consider this as our agreement to the requirements as set forth in the above mentioned letters and as our assurance of compliance. As agreed you will accept these statements in lieu of incorporating said changes into those plans and specifications now in your hands. Yours very truly, U 1< & U `HARA, INC. . lteelc Senior Vice President cc: x. Irving Douglas, Town iwAanager City of South Burlington, Vermont ' Ir. Henry Harper, Holiday Inn Muncie, Indiana. Feasibility Studies Planning Assistance 0 Building Construction Management Services Uabster~Martin Inc. Consulting Eng1ncera 1025 Airport Orlwo South Burlington, Vermont Attention: Mr. P.H. 3oherty Dear f4r" Ooharty: Ro: Construction lay -out �nd ouperivlslon of Holiday e2war-;'�ro'iot Vt. 3116 This Iettar Li to authorize y�ur firm to provide nacaaaoary.­= construction loy-out 2md construction supcznl31on on tha besiS of -3otual salary costs plus lOO'Aj thereof plusreimbursement for mlle~ +- egs at the rate of IOr, par mile and lno1domtol oxpenaes incurred -- on the -project, Vary truly yours, Irving L. Douglas Town Manager ILO:rc November 9, 19611, Departmant of Water Resources Vermont Resources Board Vermont Attention: Mr. Reginald LaRosa Dear Mr. Lalio3a: This is to inform you, that the Holiday inn I'lotel have started the installation of the sewn` e line as specified under the supervision of lJobster-1-lartin engineers. Very truly yours, Irving L. Dou-las iD Town Mana,,7er ILD: re 4r STATE OF VERMONT DEPARTMENT OF WATER RESOURCES MONTPELIER, VERMONT -;, z a.7a Z , 3 :2• —c 71. too t ' t 'C TiLof C)lz:r �Imrn bcc,� azin,,- '34-721nezn'177 R Five Prevention Division lA September 1964 amt to the w interior Leation is to for esquire Leation Rnd that ie Lone Deputy State Fire Marshal t. Lloyd E. Howard IEH/Gnw cc Department of Health Town Manager Irving L. Dou4UW ,� Fire Frevention Division 20 E,usust 1964 ,,,llen brothers & O'bars, inc. �742 lzmaar ,Yvenue Memphis lf3, 'I*nnessee iittenti.m: william P. Steele Dear Sir: In reply to, your correspr•- _,,,,.,. �-tedliKj&tgust 1964 relative to the above nared subject, thl'.;. '. --- . se this office will approve the roll door where t bey, : el co wi walk to the Ccx�ercial Building. '?'his is in eu aP this B lie a awing decor. As to lxiragraph f frnar c+arres nce and items u 12 of our correspondence dotted august 1964, s office will require the awke barriers in the corri of each f1 level. Yours t , `- Capta ohn L. Vergi. Deputy ate Fine A°gars BY Lt czwsrd LEH/env cc Air» Charles A. Vialker Froject Manager Department of health Town Ivaanager Irving L. Dcuglas ✓; Fire Prevention Division 5 October 1964 Allen Brothers & O'Hara, Inc. 3742 Lamer Avenue Memphis 18, Tennessee: Attention: 14r. .1111arn P. Steele Re: Holiday Inn South Burlingtari, Vermunt Dear Sir: This is to confirm our conversation as a result of the meeting F.t the site of the above named subject. During this meeting you submitted plans relative to certain changes in the commercial building. 1"hese D plans are approved. Hovever,, we should incorporate into this building the requirements of previous correspondence. We also received floor plans indicating certain changes in the laundry area of the motel building. These changes will be approved. However, wee do request that the equipment used in this area be U.L. Approved or approved by the .4joerai.can Gas association. Please submit to this office information showing equipment to be used and the organization which has approved this equipment. Yours truly, Captain John L. Vergin Deputy Slate t ire l�ifi hal G :mot. oyd E . o%oi rd 61 LEH:ee cc: Town t xanaaer Irving L. Douglas l.as October v, I�)Ua ,1r. A. ►,'iiliam Albert, Director Water Polution Control Division Department of Later Resources State of Vermont Montpelier, Vermont Subject: Holiday Inn South Burlington, Vermont Dear fir. Albert: With reference to your letter of June 12, 19b4 to '4r. it', P. Steele, Senior Vice President of Allen faros. 4 O'hara, Inc., I would like to take the items one by one in order to clear our thinking, before producing the final design for the treatment plant for the subject job. Item A: We have installed in the kitchen, two grease removal units at points where the grease is washed into the sewa,:e system, These units have been sufficient elsevehere. Do you require additional grease removal facilities at the treatment plant? Item 8: The sludge return from the settling tank to the aeration tank ss 3Ta7T"be by positive pumping. Item C: Our experience with treatment plants on motels has been that t'Te sludge will be completely burned up in the settling tank by slightly over -sizing the tank, and due to the fact that most sludge enters the tank durinp a vary short ,period during the morning and during the evening, the rest of the twenty-four period is sufficient to completely c;liminate sludge from the effluent. Item U: Effluent chlorination will be installed. Is a gas chlorination unit similar to Advance type "usp" acceptable in Vermont? Many states are accepting this tyre of chlorination now instead of the liquid injection units, but I know that some states have not accepted it yet and wonder if it is acceptable in your state:. Item L: The plant discharge will be carried to the point of discharge innaa sewer pine. It is our opinion that the ditch indicated on the Page Two 3-ar. A. i+ilIiam Albert October 6. 19o4 architect's plans is the un-named tributary of the t+'inooski River and is an acceptable point of discharge. If this is not so, please advise. Iten F: I%e norf:ially operate the bloaters continuously rather than put t item €�n time clocks, using one blower for stand -icy, Each blower is rated for full capacity of the unit. Item G: i°;e will provide a plugged service connection at a point in the sewerage system adjacent to the kennel, but prefer not to run to the property line at U. S. Rt. 2 at this time, since construction money is at a premium, I would like to say that your correspondence of June 12, 1964 was not completely ignored at the time of receipt. There has been extensive planning and consideration of chanPing to a septic systetr, and this has been occupying rich time up to now. t,,e are prepar%:d, at this time, to go ahead with the design of the treatment plant, and look forward to hearing from you with regard to the above points. Yours very truly, YACIR ANU +NENON I* INC. Herschel L. Powell, P, L. sj cc: !-T. lrving Douglas, Town Manager Town of South Burlington STATE OF VERMONT DEPARTMENT OF WATER RESOURCES MONTPELIER, VERMONT Mr. 14. P. Steele, Senior Vice President Allen Bros. and C'hara, Inc. 3742 lzz.ar livenue Mempltis 18, Tetinessee Dear Mr. 6teele; .tune 12, 1.964 Rc: Holiday Inn - go. Burlingtoxi, Vt. This office has reviewed your petition of May 16, 1964, for a pentit to discharge the Lreated wastes frm the referenced facility to an unnamed trib- utar, of the Winooski River in the Town of South Burlington. In giving con- sideration to your petition, this office has reviewed the drawings and specific- ations Submitted on May 15, 1964 wntitled,: Specifications - "Holiday Inn, So. Burlington, Vt." w/add. "Standar(' Details" "A Holiday Inn for So. Burlington, Vermont" The (?etails of the ' 'rawing and specifications are insufficient to allow a detailed review; however, in this regard, we have the foilowing co=ients: L. It is recon-Liended that the treatment facility involve a formal grease removal unit. b. The sludge return from the settling tank to the aeration tank should be by positive c. Experience has indicated that many installations require a separate sludge holding tank to allow the settling tank- effluent to meet adequate standards. Lonsideration should be given to including this feature In the original design rather than in subsequent construction. d. Effluent chlorination will be required. A one-half hour detention tank must be provided, together with chlorination equipment, to provide a 1 ppm residual at the detention tank outfall. e. The plant discharge must be to the flowing brook to the rear of the proposed i,,iotel location. The effluent shoulO be carried to the point of discharge in a proper sewer pipe. This office will consider an effluent ditch provided adequate land interests and public health approvals are demonstrated. Mr. W. P. Steele, Senior Vice President -2- June 12, 1964 f. Electrical controls for the blowers should include time clocks for aeration control and programming. It will be required that a ;'Mugged service connection sever be provided from point in the sewerage system adjacent to the kennel to the property line at U. S. Rt. 2 to allow inviediate connection to the municipal sewerage system when it is constructed. The municipal system is Uader design at the present time, and the service connection grade should be coordinated with Webster -Martin, Engineers, Airport Drive, South Burlington, Vermont. This office will be pleased to review the details of the plant design, in particular, yard and internal piping, elevations, size, etc., upon submittal. Based sari approval of designs, a permit will be granted. Sincerely, A. William Albert, Director Water Pollution Control Divisi,_ RA.L/jm cc: Mr. Irving Douglas, Town Manager Town of South Burlington WILLIAM H. BAUMANN CONMI.SIONER STATE OF VERMONT DEPARTMENT OF PUBLIC SAFETY MONTPELIER Yr. Alliam P. Steele Allen Brothers & O'Hara, Inc. 3742 Lamar Avenue mewphis lLj Tennessee Gentlemen: 16 October 1964 " � l 4q 4 IN REPLY REFER TO ;av, Fire Prevention Ditiaion re: Ocmer Hal i day Tnn Subject _gf,1idSX Inn_ South Burlingbn, Vermont -- - Job No, 151a Plans retained You are hereby advised that the pl,^_ns submitted to this office, relative to the above project, have been approved.including correspondence dated October 12, 1964 signed by William P. Steele, Sr. Vice President. Please advise when construction has been completed in order that an inspection may be made by a representative from this department. Yours truly, C tain J. L. Verg' Deputy State fire Tiarshal JLV f to cc: M.-. Irving Douglas, ToTAm Manager South Burlint3ton, Vermont Mr. Henry Harper, Holiday Inn Muncie, Indiana Fire Prevention Division 4 February 1965 Allen Bros. & O'Hara, Inc. 3742 Lamar iwenue Memphis 18, Tennessee Jl attentions Mr. C. A, Walker, Project b1nnager Dear sir: Holiday Inn 6 Hcttb 81tt13a®t Vert on February 30 1965 an inspection was made: relative to the Liquefied Petroleum ! teas ;and hooting equipment connected to 100 pound cylinders used in connection with berating the obwre named subject during construction. It was observed that there were several beating waits being used and several 1W pound Lique- ttf ied Poitroleum Gas cylinders located througbout the building. �- Our regulations for the Mate of vemont which is in part National Fire Pro- tection Association pamphlet No. 56 should be complied with relative to the Liquefied Petroleum Gas used. Our regulations allow the placing of 100 pound Liquefied Petroleum (Las cylinders in the building which are connected to the portable heating units. They also allow a manifold of 300 pounds of gas by weight which would be three U)O pound cylinders for each heating unit. However,, not more than one such manifold with containers may be located in the same room unless they are separated by a distance of at least 50 feet. j iar Liquefied Petroleum ()as cylinders that are not in service should be re -moved and stored outside of the building. This to also include empty cylinders. lbaere should also be: accessible at each Liquefied Petroleum Gas portable unit a wrench which can be used to shut off the gas at the tank before entering the flexible connection. During this inspection a vehicle which is used by one of the subcontractors in connection with this project was also inspected. This vehicle at one time was an old school bus and apparently is being used in cerinection with the plumbers. This vehicle contained a Connecticut registration plate. It was observed that there were two 100 pound gas cylinders located Inside this vehicle. One attached to a portable beating unit used to heat this vehicle; the other apparently empty located in a corner of the vehicle. AUM UW. & O#B" o 11M. (2) 4 February 1965 The beating unit was located so that a considerable simount of beat was re- flected ogminst the L guefieed Potrolam Gas container and was located quit e close to the Ligwee Petroleum Gas container. This office, foals that this particular sots in this vehicle presents a hazardous condition and is against our regulatimmo Tbereeforee we wild regexire that the cylinder be >mcmveed outaido this vehicle and, that there be no storage of Liquefied Fetroloum Gads im ds the Vehicle QMA fcw this purpose. Located outside of the HoUday Inn was a portable plaster mixi% roam. In this, rom are two 100 pound Li mf1sd Petroleum Use cylinders partially `) covered with sand. cylinders should be removed from this portable building. c,ura 'fly., captain J. L. Vorgin Deputy state Fire marshal Hy Lt. LlOyd P. Howard DEPUTY FIRE MARS, South Burlington,, Verumt LJI win fql.4A&, n9alme7cr bris abr T ys-r qvsrf I jarf-j ;r ydixtq 91 a apfixbllud 3 -11 bits .Ertl ci c sfqJoF -Y9qtsm 10 !Iljbllff(f baS a9Off4rll5'%C bil.3 ',RWSI Pfl.�bfRfd f-lis t-o7rT s;V , ric-tipfif I --f, uff I o mooT 9rid Ic .7,rlpr 'N ysm :bglga Tj y TO WHOM IT MAY CONCERN: I hereby certify that I have examined the lands and premises of Harper Hotels of Vermont, Inc. and the buildings situate thereon and that the same comply with all applicable zoning and building laws and ordinances and building restrictions of the 'town of South Burlington, Vermont. Dated: May 4, 1967. Henry J. LeClair Town Manager May 3, 1967 1. ,r. Robert H. Trdr 136 College Street Burlington, Varmoi Re: Holiday Inn Williston Roi South Burli,-4 Dear Mr. Frdmann: �'he South Burling - that the holiday Inn of AmericjL has codes grid ordinances with respect to i:L/h d met all the town's the recent addition. Very truly yours, Henry LeClair Town Manager STATE OF VERMONT DEPARTMENT OF WATER RESOURCES MONTPELIER. VERMONT We6aflAr 16, j. v b4 Mr. N. P. Steele, Dior Bice! President Allen Brothers & 018ara, Lea. 32 2 Lamer Avenue Mends, 16, TeImnessee RE: Holiday I=, South Burlington, Vesmunt Dear Mr. Steele: Your petition for a permit to discharge an effluent from a seeondary aewage treatment facility serving the referenced commercial unit to an cnummed tributary to the Winooski Giver has been reviewed. In giving consideration to this permit, recognition has boon given to discussions and the following documents submitted by you and Yager and Noma, Inc. a) Specifieations eta mi.ttsd May 130 1964" entitled "Holiday Ina, South Eariiington, Versiont," wlAdt. #1. b) "Stesdard Details" submitted NW l5, 1964. c) Drawing submitted May 15, It" entitled. "A holiday Inn for Sonth Burlington:, Vermont". d) Yager and Xenon, Inc. letter of October 8, 1964 e) Discussion with Mr. Drell of Yapr and bey as October 15, 1964. f) Materials list and shog drawings dated September 29, 1964 and. Vibes 3, 1964 respaetiwly, submitted November 10, 1064 to- gether with letter of trawad.ttal. You are hereby granted, in accord with Hater Resources Board Policy,, a temporary permit to dise#a Ve a chlorinated effluent from a properly opera- ting ssration type treatment: facility to an unnamed tributary of the Win- ooski liver is accord with ", above mentioned documents, and subject to the following canditioms: a) That connection of the, surer from this commercial establiaimaint will be swain to the prey Imroicipal sneer system lwdiately upon its completion. Mr. W. P. Steals Poo 2 l6, 1964 b) That mutor no condition will stem water be connected to the sealer sygtes. a) That should this effluent by itself or in caabinsti+nn with others create admve conditions in this receiving vators,, anrepri4te corrective action will be taken by the owner. C.esraLialt XAL:rt j as/ 1k. Irving Maass, Tows Manager Mr. C. A. Welker, Project X*&*W Mr. Herschel xowell, P.S. Mr. Edward L. Tracy 5 August 1964 Allen Brothers & OlHora, Inc. 374-ra i amer Avenue Fleriphi.s 18, Tennessee Attention: -Co A. Walker Re% Bear Sir: Fire Prevention Division This office has received two setsNfhi the above named subject. The first set was of a two story bHowever, then second set received on 30 July 1964 i sy fire resistant building with a Conmercigal BuZnts onejacent to this four story building. This office receivedrelative the abogvre named subject on 30 July 1964 for appBefore a 1 can be given, this office must receive an addeicating t the following changes will be made (1);IIevel. plans Indic to s standpipe in each stairwell with a fire depat connects at each floor level. Also the third stand- pipehe center o building is connected to a hose at each floe This be accepted by this office. However, the hose: be of suf sett length so that Ue esquipment can be effeused ny portion of each floor that that particular hose (2) Fire extinguishers for each floor level to be used in connection with the sleeping quarters shall be located adjacent to each stairwell and these mounted in well cabinets with the bottoms about thirty (30) inches from the floor. There will be at .least two 2a gallon Pressurized ►rster or Soda Acid fire extinguishers for each floor level with special fire extinguishers of CO2 or Dry Chemical type of at beast 5 lb. capacity located in the Mechanical Roam and Electrical Room. There will also be one 2c; ,gallon Pressurized water or Sods ;4U located in the Linen storage area. Allen Brothers & O'Hars,o Im. .- 2 o 5 August 1964 ::ws to c linenchute which extends .. )t .:.D# all floor levels do= into the Linen Storage Rom,. Mas chute will extend full size through the roof and at least three feet &ban the roof and terminate beat actuated o"r. The bottctof the chute which empties Into the Linen Storeoe Rocim to to be eqdaed with an approved self closing door. Each opening into this Chute from each floor level will be equipped with an Underwriteral laborotorles's approved door wtdch is self closing with positive (4) Provide a sprinkler at the tots of the linen chute and provide sprinklers for the Linen storage area, 2h+ese any be hooked into the domestic sy$tem so long as once they are actuated.. it will not deplete the water supply for other ftirefightt.ng eq nt. 'Tbese sprinklers will also be connected into the fi.re ale , system in such a r-ianner that if one is actuated, it will es 'the* fire ale=. Provide (6) Plans indicate a roll door in t buildi oonnecto to the walk do Corme sbaft. Tbose are to be connected Into fire system. Building. Thin may • :. a• .. door with a self . . • . F Closer. (7) ;,a discussed with you.. the le from stairwell 42 to the outside may be a hollow, 0 (8) PIWIS indicate tomeeet tion system for this building. Iicnaysr, is im,ose l for writer to :locate any automatic fire tection equi, t in the corridors, stairwailci or elevator *hertz We will re that this building be coipletely covered th an automat fire detection system including all rooms torage arse sleeping quarters,, stair+ lie and c . 1 be located as indicated. Ho t be for peel which will include a troub signal loess as discussed with you. This must also inc a signal at Clerk's Desk. The system must comply with, requireemen ch are in part Natitmal Fire Protection Asee tion past 2. It =at have as r n alternate mean of B wet dell be ry with trickle charger. (9) As th you, this building must be equipped with emergency lighting. At the present time the owner is Studying whether or not a standby motor is to be geed. If this is not used, the alternate means of poser will be nickel cadmium wet cell batteries with trickle charger. (10) Interior finish used in connection with this Wilding is to panne a hazardous classification as follows: Corridors and stairwells +egci huzaerdouu room to have: a Class A rating +see to Hamra spread, developed, and fusel contributed. Sleeping areas and other rooms say be Class B. Allen Brothers & (?'Herat Inc. - 3 • 5 august 1964 (11) Provide an outside alarm connected into the fire detection system for this building. (22) provide wake barriers in about the center of the corridor on each floor level. 'these are to be installed to obtain 3/4 of an hour fire rating and must extend all the way to the slab above. Doors in these barriers are to have the same fire rating and be equipped with self closers. These doors may be held open electrically and controlled by ea K*e detectors or co=wcted into the fire alarm system in such a manner that they will close automatically should the alarm systems be actuated . .14 al.ass in the doors will be 1/4 inch wired glass and irwtalled to obtain a one hour fire rating. C(MaRCIAL BUILDING (1) Provide the necessary fire extinguishers for building with special Sire extinguishers to be .located in the kite nt saechanical room and phone equipsent row. If further informati is needed please contact this office. (2) Plans indicate an overhead door between dock and - the vestibule leading tr� the kitchen eivi _s area ffice will. require a free swing door a s locat in additio to the overhead door. This may be i d in the c rhead door. (3) Provide the additional ligh exi igis as discussed with you. This will include a lighted exit s r t�'�e overhead door between the dock and the vestib� (4) Change fireh04# core doors soibk tco e doors as discussed with you; the door tween the sto ;fie room and the corridor adjacent to the regi.strati area and the d between the Porter's i?ucsrss and the hall and the d between the kitchen storage and the receiving area. // (5) gAl6afied Petroleu-t-4w s to be iYij-talled in accordance with Verm4t Regulations hich are in part National ilre Protection Ass tion Pemphle*e �54 and #-56. Yours � CaptaihVohn L. Deputy arcs Itr. Irving L. Douglast Town Flanabvr 'r Department of health Department of Liquor Control Fire I:'r�-vvert4ion Divisj_()p 15 July 1964 Mr. Nfilliam ke Steele, :senior Vice President Allen Brothers and O'Hara, Inc. s di2 Lmuar ,,venue Memphis 18, Tennessee Re: Holiday Inn Sout , V�zY.;curt Dear Oir: W 9 July 1964 the writer met with ar►i. the Manager for the Town of South Burlington at the Towr � Is o,f relative to the abarve named subject. while at the m� < <..:.m * 1. ? � . y floor plans were given to the writer by you with the undo rs:, .' I...,ut working p:l.Faxis for this project would be submitted off'i or approval. These plans also are to include specifics During; this meeting t were two su cts ch the writer was to discuss with the Deput :state Fire Ma 1 and advise you relative to the decision iTode by the uty Fire Mars Captain Vergin was contacted and the two following jects were ussed with him. (1) VAlding. pl.N S„� a boiler room on the fourth floor of thhi. boiler room is to be removed frcra the fourth floor id level with exits from the boiler romr, separ fron any exitway used by the public in c=1eI (2) P indica andpipes and hoses located in the sleeping areas of ng. This office will request that the stand- pipes be fa wet system with a fire department connection located on the outside of the building for emergency use by the fire department. Yours truly, Captain John L. Vergin Deputy imitate Pyre Marshal By Lt q�7aoyd E . Howard IEH/snw t cc: Mr. Irving L. Douglas, Town 1.1anager Department of health Department of Liquor Control l July 1964 Mrs W, Fo Tharas Box 102 Cumberland Mille .Station Westbroak, Maine Re: Dear Sir: Fire Prevention Division Plans were received at this office tive to above rimed wab jest end correspondence was sent to you 3A 1964 requesting certain requirements to be incorporated into tiara of this building. 11v first paragraph of orres .race tes that we should receive addendums Indic rag that the to in the correspondence be received by this a and approve vsn revious to the time c onatruction is a A yet we be not heard from you relative to this. Will ym ple advise this rice as to the status of this project. We have ved in armetidn��--Vds may be changed to a four story building If this is dq e, then this office will have further requi to to be cord with and incorporated into the construction of the lding. Yours t Captain J Ver514,, � Deputy State sus Mahal By it ayd E . IIoward i3✓R/snw cc: Mr. Irving L. Dougl,.as, Tom der v Department of Health Department of Liquor Control is 'Tur 7 s-64 ik X 10P Cumbe rLsind Mills Station ryes`brook, Maine ;L {ect: ffcl.Lda.,` inn, South Burlingtori, Vermont Deer 5 i. Befcre approvn.1. cr.n be given for the construction of this buildilig, t^.is office mint receive revised plans or addenci•mis indicating that the foU,-virng wi11 be complied with: UNIT. "B" and "C;' of MMHANdIC LL SLTILDIN a 1. Provide barriers at the following location", these barriers to have a 3, " hour fire} rating. a"'he doors in the barriers are to have trE BsxNe rntiae end to l e equipped. with self closers. If vision etnels Q.re ,wsec n 4iu: doors, then v1 s.J o i paiac i.s are to be of vrlre S:L:iss. Barriers must extend all the way to the slab above. a. install a brxrriev on. the firs, floor le rel of Unit "B" where t e corridor from the sleeping- cr-iarte:-s con.nvct vrith vestibule dccr to swing, into vest' . ule Y.3. b. Insta11. a berrier at the sec:oi;d floor ,Ji Unit "B" wlwre. the co"idor from the sleeping quarters connects with the cor-ridor adjacent to the chp- icP 1 bui 1r..ing, this door to swing toward the corridor adj'acert to the mechai ical. building.. c . Install n harrier at second floor level In Unit "B" where stairwell one connects with the corridor to the sleeping area., dour to ssri:af; onto t1> stairwP11. this to have about one hour fare rating. d. install a barrier in Unit "C" first floor level where tine corridor to the sleeping area connects with vestibule i3, door to owing town---d vestibule h. e . install a barrier on the second floor level of Unit "C" where the corridor to sleeping area connects with the area adjacent to stair- we1l #2, door to swing toward stairwell #2. f. Install a barrier an the secood !Loaf lava of Uh1t "C" where the corridor to the sleeping area connects Frith the area adjacent to stairwell fe, this door to swing toward the area adjacent to stairwell , this to have about one hcrar fire rating. �,. install a barrier in Unit "C" at the second floor level were: stairwell 3 connects to the corridor leading to the sleeping area, this door to swing into the stairwell. 2. All doors leading to the Janitor's closets area storage areas which are exposed to corridors or exitways are to have a Class "B" re ting . 3. Interior finish classifications in corridors and vestibules, this to include mmechani.cal buildingi to be of Class ruing end the sleeping quws tern :sot loss than Class "C". 4. Pletz u submit Imformra,tion as tc !'ire exy` - gsishers, types of fire extingruishere to be used and the locations f:ar these extinguishers, t iffs to include sleeping area and tne- mechanical 't`L' 1d:L. . >. Equip this building with a fire alarm system, this to be inc laded in Units "B" and "C" .i n.d the mechaxiical '.ral ].ding. idarns or bells ^.re to be located in an area. :;o as to alert nL ?:people in the bui_iriir in cv.ce ofan emergency, and manual gall stations are to be located at or near the exitways. (Connect this system into an automatic fire detection system, the autcxaatic detection spates: to be installed in accordance with Vermont Regulations which are :n part National Fire Prevention Association Pamphlet No. 72. This system is to be., installed by an electrician licensed to iz"+.a..L'. these systems In the 13tatc of Vermont. Te alternate means of power must be wet a ll'pa.ttery and trickle charger. 6. 73,rovide emergency light; for 'Units "B" and "C" installed so as to light up corridors, stairvel-la and eft nyE in case of an emergency. The emergency lighting oystem is to have ea alternate means of power of nickel cadmium battery and. trickle charger. CORKMIAL WILDI ra 1. Provide a door to the aitside of this building from the roaa label "Meeting Room No. 2"" or the corridor leadir_.g from "!+eating Room No. 2" to door labeled '14% this door shall be located. in the southerly outside wall of this roa& to swing out in the line of travel for anyone having the area through this exitway, this door to be egaipped with a lighted exit sign located in a manner in which it will li.rect persons to this exit. 2. Provide information as to fire extinguishers,, their locations and types of extinguishers to be used in this building. 3. Provide emergency lights for this building, units to have an alternate means of power of nickel cadmium battery and trickle charger. 4. Provide a fire alarm system for this building, this to include mmal pull stations with horns or bells. This system is to have an alternate mews of pmmr with wet cell battery and trickle charger. It is recommaded that an autasatic fire detection system also be install d in this building. 5. Provide inftrration as to interior finish classification for this building, this *.c _-nclude ceiling, and wall finiz'i ec, this classifi- cation to include fL,---Te spread, _,molw developed and fuel contributed. This building should not have rater than a Clzzs "B" flame spread. 6. Doers from general s•t or- c: and electrical penel roan show hollow core doors, these are tc be c`=gerl to a solid core door. 7• If Liquefied C'tn�l.E.ixI xikc In doomed Lion with this bul3di.ng or any other xm i t , ,,.a: Z cv <<Ge rn 4s v comply � i th Je rnont Regulations which are in pest National Fire Prctection Association Pamphlets No. 58 and No. 5L'. &. The electrical in ta1.l.Fttion r.-,ust comply wit!z Ver-•.ax t Re—LALIrations vhicti are in ppr t of the Netional Electrical Code. Yours truly, Capt,nAm J. L. Vert Deputy State Fire Marsh..: By: Lt . Lloyd :. icwa rd LEH j to