HomeMy WebLinkAboutAgenda 07_Bourne supplemental plans760 & 764 SHELBURNE RD. & 31 SWIFT ST.
SOUTH BURLINGTON, VT
SHELBURNE & SWIFT
Engineer & Landscape Architect:
TRUDELL CONSULTING ENGINEERS (TCE)
478 BLAIR PARK ROAD
WILLISTON, VT 05495
(802) 879-6331
Owner/Applicant:
GARY BOURNE
414 WEST GROVE
MIDDLEBORO, MA 02346
(508) 735-4970
DRAWING INDEX
Architect:
RABIDEAU ARCHITECTS
550 HINESBURG ROAD
SUITE 101
SOUTH BURLINGTON, VT 05403
PROJECT DESCRIPTION:
THE PURPOSE OF THIS PROJECT IS TO REDEVELOP THE FORMER GAS STATION
AND RESTAURANT SITE AND CONSTRUCT A MULTI-UNIT RESIDENTIAL
BUILDING, COMMERCIAL AND FINANCIAL INSTITUTION SPACES. THE
PROJECT WILL UTILIZE MUNICIPAL WATER AND SEWER.
" LOCAL PERMITTING" SUBMISSION SET
(NOT FOR CONSTRUCTION)
TCE PROJECT NO: 22-523
04/15/2024 ISSUED FOR PERMITTINGLAST REVISED:
USE AND INTERPRETATION OF THE DRAWINGS
BEFORE USING THESE PLANS ENSURE THAT YOU HAVE THE LATEST REVISION
1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities. They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including,
but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans,
private and public utilities, and other pertinent permits for construction.
3. Owner and Architect are responsible for final design and location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property. Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains the most current revisions. If unsure, please contact TCE.
PERMIT DESCRIPTION: PRELIMINARY & FINAL PLAT
TAX ID:
PARCEL ID: 1540-00760
SPAN: 600-188-10694
PROJECT
LOCATION
C0-00 Cover
C1-00 Legend & Notes
C1-01 Existing Conditions Plan
C1-02 Demolition & EPSC Plan
C2-00 Overall Site Plan
C2-01 Layout & Materials
C2-02 Grading Plan
C3-01 Utility Plan
C4-01 Existing Stormwater Plan
C4-02 Proposed Stormwater Plan
C8-01 Site Details
C8-02 Site Details
C8-03 Site Details
C8-04 Water Details
C8-05 Sanitary Details
C8-06 Storm Details
C8-07 Storm Details
C8-08 EPSC Details
C8-09 EPSC Handbook Page 1
C8-10 EPSC Handbook Page 2
LA-1.0 Landscape Plan
LA-2.0 Landscape Details
LA-2.1 Site Details
S1-01 Plat
LI-01 Lighting Plan
No. 8917
CIVIL
JENNIF E R ANN DESA
UT
E
L
S
ST A T E O F VER
M
O
N
T
P
R
O
F
E SSIONAL E N GI NEER
LICE N S E D
C2-03 Phasing Plan
C3-02 Utility Crossings Plan
卷楦琠却牥整
卨敬
扵
牮
攠
副
慤
16'-8"1'-8"16'-11"3'-01
2"13'-61
2"3'-01
2"10'-4"2'-0"9'-111
2"
78'-91
2"
45
'
-
7
1 2"
9'
-
1
1
1 2"
2'
-
0
"
26
'
-
1
1
"
3'
-
9
"
3'
-
0
"
16'-8"20'-2"3'-01
2"13'-61
2"3'-01
2"20'-8"
12
'
-
4
"
3'
-
4
"
2'
-
7
"
3'
-
6
"
21
'
-
3
"
EAST ELEVATION (PRIMARY PARKING)
NO
R
T
H
E
L
E
V
A
T
I
O
N
(
S
W
I
F
T
P
A
R
K
I
N
G
)
SO
U
T
H
E
L
E
V
A
T
I
O
N
(
F
U
T
U
R
E
S
T
O
R
E
)
WEST ELEVATION (SHELBURNE STREET)
LONG TERM
BICYCLE
STORAGE
+/- 3,350 SQ. FT.
A-1
PROPOSED PLAN
JPMORGAN CHASE BANK
720 Shelburne Road
1521451-00
08/23/2023
PROJECT
SEAL
SCALE
PROJECT NO.
DATE
DRAWING
IN CONSIDERATION OF RECEIVING DRAWINGS FROM TPG ARCHITECTURE LLP IN
AN ELECTRONIC FORM, THE RECIPIENT AGREES, TO THE FULLEST EXTENT
PERMITTED BY LAW, TO HOLD HARMLESS AND INDEMNIFY TPG ARCHITECTURE
LLP FROM AND AGAINST ALL CLAIMS, LIABILITIES, LOSSES, DAMAGES, AND
COSTS, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES, ARISING OUT OF,
OR IN ANY WAY CONNECTED WITH THE USE, RE-USE, MIS-USE, MODIFICATION,
OR MISINTERPRETATION OF THE MACHINE-READABLE INFORMATION PROVIDED
BY TPG ARCHITECTURE LLP UNDER THIS AGREEMENT.
TPG ARCHITECTURE, LLP
132 WEST 31ST STREET, 5TH FLOOR, NEW YORK, NY 10001
212.768.0800 | TPGARCHITECTURE.COM
31 PENN PLAZA
DOB PAGE
NYC DOB NO.
CAD FILE NO.
DWG NO.
SOUTH BURLINGTON
Burlington, VT 05403
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
1 PROPOSED PLAN SCALE: 1/4"=1'-0"
DASHED LINE INDICATES FUTURE PHOTOVOLTAIC PANEL ARRAY
AREA. AREA FOR FUTURE PV PANELS SHALL BE CLEAR OF ALL
SURFACE-MOUNTED CONDUITS, CONDESATE DRAINS AND OTHER
INFRASTRUCTURE. STRUCTURAL LOADING IS 10 PSF AT FLAT ROOFS.
1 ROOF PLAN SCALE: 1/4"=1'-0"
A-2
ROOF PLAN
JPMORGAN CHASE BANK
720 Shelburne Road
1521451-00
08/23/2023
PROJECT
SEAL
SCALE
PROJECT NO.
DATE
DRAWING
IN CONSIDERATION OF RECEIVING DRAWINGS FROM TPG ARCHITECTURE LLP IN
AN ELECTRONIC FORM, THE RECIPIENT AGREES, TO THE FULLEST EXTENT
PERMITTED BY LAW, TO HOLD HARMLESS AND INDEMNIFY TPG ARCHITECTURE
LLP FROM AND AGAINST ALL CLAIMS, LIABILITIES, LOSSES, DAMAGES, AND
COSTS, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES, ARISING OUT OF,
OR IN ANY WAY CONNECTED WITH THE USE, RE-USE, MIS-USE, MODIFICATION,
OR MISINTERPRETATION OF THE MACHINE-READABLE INFORMATION PROVIDED
BY TPG ARCHITECTURE LLP UNDER THIS AGREEMENT.
TPG ARCHITECTURE, LLP
132 WEST 31ST STREET, 5TH FLOOR, NEW YORK, NY 10001
212.768.0800 | TPGARCHITECTURE.COM
31 PENN PLAZA
DOB PAGE
NYC DOB NO.
CAD FILE NO.
DWG NO.
SOUTH BURLINGTON
Burlington, VT 05403
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ACM ROOF EDGE
12'-6"
T.O. SLAB
0'-0"
T.O. WINDOW OPENING
10'-0"
T.O. PARAPET
21'-8"
T.O. WINDOW OPENING
19'-0"
T.O. PARAPET
24'-9"
T.O. PARAPET
22'-11"
ACM ROOF EDGE
12'-6"
T.O. SLAB
0'-0"
T.O. WINDOW OPENING
10'-0"
T.O. PARAPET
21'-8"
T.O. WINDOW OPENING
19'-0"
T.O. PARAPET
24'-9"
T.O. PARAPET
22'-11"
1 WEST ELEVATION (SHELBURNE STREET)SCALE: 1/4"=1'-0"
2 NORTH ELEVATION (SWIFT STREET)SCALE: 1/4"=1'-0"
A-3
EXTERIOR ELEVATIONS
JPMORGAN CHASE BANK
720 Shelburne Road
1521451-00
08/23/2023
PROJECT
SEAL
SCALE
PROJECT NO.
DATE
DRAWING
IN CONSIDERATION OF RECEIVING DRAWINGS FROM TPG ARCHITECTURE LLP IN
AN ELECTRONIC FORM, THE RECIPIENT AGREES, TO THE FULLEST EXTENT
PERMITTED BY LAW, TO HOLD HARMLESS AND INDEMNIFY TPG ARCHITECTURE
LLP FROM AND AGAINST ALL CLAIMS, LIABILITIES, LOSSES, DAMAGES, AND
COSTS, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES, ARISING OUT OF,
OR IN ANY WAY CONNECTED WITH THE USE, RE-USE, MIS-USE, MODIFICATION,
OR MISINTERPRETATION OF THE MACHINE-READABLE INFORMATION PROVIDED
BY TPG ARCHITECTURE LLP UNDER THIS AGREEMENT.
TPG ARCHITECTURE, LLP
132 WEST 31ST STREET, 5TH FLOOR, NEW YORK, NY 10001
212.768.0800 | TPGARCHITECTURE.COM
31 PENN PLAZA
DOB PAGE
NYC DOB NO.
CAD FILE NO.
DWG NO.
SOUTH BURLINGTON
Burlington, VT 05403
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
TOTAL TRANSPARENT GLAZING PERCENTAGE (MINIMUM 75% REQUIRED): 83% (562 SQ.FT.)
TOTAL OPAQUE GLAZING PERCENTAGE: 17% (95 SQ.FT.)
PRIMARY STREET GLAZING PERCENTAGE (SHELBURNE ROAD)
MINIMUM REQUIRED ACROSS WIDTH
OF FACADE: 60%ACTUAL PROVIDED: 63.5%
SECONDARY STREET GLAZING PERCENTAGE (SWIFT STREET)
MINIMUM REQUIRED ACROSS WIDTH
OF FACADE: 40%ACTUAL PROVIDED: 76 %
T.O. SLAB
0'-0"
T.O. PARAPET
24'-9"
T.O. PARAPET
22'-11"
T.O. SLAB
0'-0"
T.O. WINDOW OPENING
10'-0"
T.O. WINDOW OPENING
19'-0"
T.O. PARAPET
24'-9"
T.O. PARAPET
22-11"
T.O. PARAPET
21'-8"
JPMORGAN CHASE BANK
720 Shelburne Road
1521451-00
08/23/2023
PROJECT
SEAL
SCALE
PROJECT NO.
DATE
DRAWING
IN CONSIDERATION OF RECEIVING DRAWINGS FROM TPG ARCHITECTURE LLP IN
AN ELECTRONIC FORM, THE RECIPIENT AGREES, TO THE FULLEST EXTENT
PERMITTED BY LAW, TO HOLD HARMLESS AND INDEMNIFY TPG ARCHITECTURE
LLP FROM AND AGAINST ALL CLAIMS, LIABILITIES, LOSSES, DAMAGES, AND
COSTS, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES, ARISING OUT OF,
OR IN ANY WAY CONNECTED WITH THE USE, RE-USE, MIS-USE, MODIFICATION,
OR MISINTERPRETATION OF THE MACHINE-READABLE INFORMATION PROVIDED
BY TPG ARCHITECTURE LLP UNDER THIS AGREEMENT.
TPG ARCHITECTURE, LLP
132 WEST 31ST STREET, 5TH FLOOR, NEW YORK, NY 10001
212.768.0800 | TPGARCHITECTURE.COM
31 PENN PLAZA
DOB PAGE
NYC DOB NO.
CAD FILE NO.
DWG NO.
SOUTH BURLINGTON
Burlington, VT 05403
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
A-4
EXTERIOR ELEVATIONS
1 EAST ELEVATION (PRIMARY PARKING)SCALE: 1/4"=1'-0"
2 SOUTH ELEVATION (FUTURE STORE)SCALE: 1/4"=1'-0"
OH
OH
OH
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB SB SB SB SB SB SB SB SB SB SB
SBSBSB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
1
0
'
1-STORY
BUILDING
1-STORY
BUILDING
SH
E
L
B
U
R
N
E
R
O
A
D
(
U
.
S
.
R
O
U
T
E
7
)
SWIFT STREET
1-STORY
BUILDING
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
UP
UP
UP
UP
UP
SSSSSSSS
CROSSWALK SIGNAL
POLE
LOT 1:
FINANCIAL
INSTITUTION
±3,350 SF
FFE 212.0
15
7
15
LOT 3: MULTIFAMILY
RESIDENTIAL
27 DU
FFE 217.0
BFE 207.0
GARAGE
ENTRANCE
D
D
LOT 2: MIXED USE
1ST FLOOR: COMMERCIAL
2ND FLOOR: 3 DU
± 3,240 SF
FFE 212.0
1
1,840 SF SITE
AMENITY SPACE
(SNIPPET PARK)
890 SF SITE
AMENITY SPACE
(SNIPPET PARK)
DEDICATED
PARKING FOR
COMMERCIAL USES
ONLY DURING
BUSINESS HOURS
1,830 SF SITE
AMENITY SPACE
(SNIPPET PARK)
RAISED CROSSWALK, TYP.
RAISED CROSSWALK, TYP.
PROPOSED
BIORETENTION
BASIN, TYP.
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PROJECT LOCATION
0
Feet
Graphic Scale
20 40 60
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Overall Site Plan
C2-00
03/01/2024
1" = 20'
22-523
PJM
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
ZONING DISTRICT INFORMATION:
ZONING DISTRICT:C1 R15
OVERLAY DISTRICT:URBAN DESIGN (UDO)/PRIMARY NODE
TRANSIT DISTRICT
TRAFFIC DISTRICT / ZONE 1
SETBACKS
FRONT YARD:30 FT (COMMERCIAL 1)
FRONT YARD:10 FT (PROPOSED PUD)
SIDE YARD:10 FT
REAR YARD:30 FT - N/A - CORNER LOT
LOT COVERAGE:70% MAX.
BLDG COVERAGE:40% MAX.
LOT SIZE:40,000 SF MIN.
HEIGHT REQ'S:2 STORIES MIN.
PLAN INFORMATION:
EXISTING
760 SHELBURNE ROAD
LOT SIZE: 17,553 SF / 0.4 AC
BUILDING COVERAGE: 4,229 SF / 0.1 AC OR 24.1%
TOTAL LOT COVERAGE: 14,901 SF / 0.34 AC OR 84.9%
FRONT YARD:
SHELBURNE RD: 1,113 SF / 0.03 AC OR 90.3%
SWIFT ST: 1,127 SF/ 0.03 AC OR 88.0%
764 SHELBURNE ROAD
LOT SIZE: 26,572 SF / 0.61 AC OR 37.1%
BUILDING COVERAGE: 2,812 SF / 0.06 AC OR 10.6%
TOTAL LOT COVERAGE: 19,914 SF / 0.46 AC OR 74.9%
FRONT YARD (SHELBURNE): 431 SF / 0.01 AC OR 43.3%
31 SWIFT STREET
LOT SIZE: 16,575 SF / 0.38 AC
BUILDING COVERAGE: 6,157 SF / 0.14 AC OR
TOTAL LOT COVERAGE: 14,118 SF / 0.32 AC OR 85.2%
FRONT YARD (SWIFT): 948 SF / 0.02 AC OR 77.3%
LOT INFORMATION:
TAX MAP NO. 1540-00760
BOURNE GARY J,
V. 188 P 137-8
17,553 SF / 0.42 AC
TAX MAP NO. 0700-00031
BOURNE GARY
V. 326 P 50-2
16,575 SF / 0.40 AC
TAX MAP NO. 1540-00764
764 SHELBURNE RD LLC,
C/O GARY BOURNE
V. 1035 P 233-4
26,572 SF / 0.61 AC
PROPOSED - INDIVIDUAL LOTS
760 SHELBURNE ROAD
LOT SIZE: 8,054 SF / 0.18 AC
BUILDING COVERAGE: 3,350 SF / 0.08 AC OR 41.6%
TOTAL LOT COVERAGE: 5,137 SF / 0.12 AC OR 63.8%
FRONT YARD:
SHELBURNE RD: 346 SF / 0.007 AC OR 37.7%
SWIFT ST: 166 SF / 0.004 AC OR 21.8%
764 SHELBURNE ROAD
LOT SIZE: 6,287 SF / 0.14 AC
BUILDING COVERAGE: 3,240 SF / 0.07 AC OR 51.5%
TOTAL LOT COVERAGE: 5,262 SF / 0.12 AC OR 83.7%
FRONT YARD (SHELBURNE): 324 SF / 0.007 AC OR 36.4%
31 SWIFT STREET
LOT SIZE: 46,359 SF / 1.06 AC
BUILDING COVERAGE: 10,620 SF / 0.24 AC OR 22.9%
TOTAL LOT COVERAGE: 35,107 SF / 0.81 AC OR 75.7%
FRONT YARD:
SHELBURNE RD: 196 SF / 0.004 AC OR 45.6%
SWIFT ST: 1,151 SF / 0.03 AC OR 66.3%
PARKING:38 SURFACE SPACES
27 GARAGE SPACES
TOTAL:65 SPACES
PROPOSED - OVERALL PUD
760 SHELBURNE ROAD
PUD AREA: 60,700 SF / 1.39 AC
BUILDING COVERAGE: ±17,210 SF / 0.40 AC OR 28.4%
OVERALL COVERAGE: ±45,506 SF / 1.04 AC OR 74.9%
FRONT YARD:
SHELBURNE RD: ±866 SF / 0.02 AC OR 39.0%
SWIFT ST: ±1,317 SF / 0.03 AC OR 52.7%
SNOW STORAGE NOTE:
SNOW WILL BE STORED ONSITE IN LANDSCAPE BEDS AND GREEN
SPACES WHERE FEASIBLE. SNOW THAT CANNOT BE STORED ONSITE
WILL BE REMOVED FROM THE SITE.
LOT 1:
LOT 2:
LOT 3:
16'-8"1'-8"16'-11"3'-01
2"13'-61
2"3'-01
2"10'-4"2'-0"9'-111
2"
78'-91
2"
45
'
-
7
1 2"
9'
-
1
1
1 2"
2'
-
0
"
26
'
-
1
1
"
3'
-
9
"
3'
-
0
"
16'-8"20'-2"3'-01
2"13'-61
2"3'-01
2"20'-8"
12
'
-
4
"
3'
-
4
"
2'
-
7
"
3'
-
6
"
21
'
-
3
"
EAST ELEVATION (PRIMARY PARKING)
NO
R
T
H
E
L
E
V
A
T
I
O
N
(
S
W
I
F
T
P
A
R
K
I
N
G
)
SO
U
T
H
E
L
E
V
A
T
I
O
N
(
F
U
T
U
R
E
S
T
O
R
E
)
WEST ELEVATION (SHELBURNE STREET)
LONG TERM
BICYCLE
STORAGE
+/- 3,350 SQ. FT.
A-1
PROPOSED PLAN
JPMORGAN CHASE BANK
720 Shelburne Road
1521451-00
08/23/2023
PROJECT
SEAL
SCALE
PROJECT NO.
DATE
DRAWING
IN CONSIDERATION OF RECEIVING DRAWINGS FROM TPG ARCHITECTURE LLP IN
AN ELECTRONIC FORM, THE RECIPIENT AGREES, TO THE FULLEST EXTENT
PERMITTED BY LAW, TO HOLD HARMLESS AND INDEMNIFY TPG ARCHITECTURE
LLP FROM AND AGAINST ALL CLAIMS, LIABILITIES, LOSSES, DAMAGES, AND
COSTS, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES, ARISING OUT OF,
OR IN ANY WAY CONNECTED WITH THE USE, RE-USE, MIS-USE, MODIFICATION,
OR MISINTERPRETATION OF THE MACHINE-READABLE INFORMATION PROVIDED
BY TPG ARCHITECTURE LLP UNDER THIS AGREEMENT.
TPG ARCHITECTURE, LLP
132 WEST 31ST STREET, 5TH FLOOR, NEW YORK, NY 10001
212.768.0800 | TPGARCHITECTURE.COM
31 PENN PLAZA
DOB PAGE
NYC DOB NO.
CAD FILE NO.
DWG NO.
SOUTH BURLINGTON
Burlington, VT 05403
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
1 PROPOSED PLAN SCALE: 1/4"=1'-0"
DASHED LINE INDICATES FUTURE PHOTOVOLTAIC PANEL ARRAY
AREA. AREA FOR FUTURE PV PANELS SHALL BE CLEAR OF ALL
SURFACE-MOUNTED CONDUITS, CONDESATE DRAINS AND OTHER
INFRASTRUCTURE. STRUCTURAL LOADING IS 10 PSF AT FLAT ROOFS.
1 ROOF PLAN SCALE: 1/4"=1'-0"
A-2
ROOF PLAN
JPMORGAN CHASE BANK
720 Shelburne Road
1521451-00
08/23/2023
PROJECT
SEAL
SCALE
PROJECT NO.
DATE
DRAWING
IN CONSIDERATION OF RECEIVING DRAWINGS FROM TPG ARCHITECTURE LLP IN
AN ELECTRONIC FORM, THE RECIPIENT AGREES, TO THE FULLEST EXTENT
PERMITTED BY LAW, TO HOLD HARMLESS AND INDEMNIFY TPG ARCHITECTURE
LLP FROM AND AGAINST ALL CLAIMS, LIABILITIES, LOSSES, DAMAGES, AND
COSTS, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES, ARISING OUT OF,
OR IN ANY WAY CONNECTED WITH THE USE, RE-USE, MIS-USE, MODIFICATION,
OR MISINTERPRETATION OF THE MACHINE-READABLE INFORMATION PROVIDED
BY TPG ARCHITECTURE LLP UNDER THIS AGREEMENT.
TPG ARCHITECTURE, LLP
132 WEST 31ST STREET, 5TH FLOOR, NEW YORK, NY 10001
212.768.0800 | TPGARCHITECTURE.COM
31 PENN PLAZA
DOB PAGE
NYC DOB NO.
CAD FILE NO.
DWG NO.
SOUTH BURLINGTON
Burlington, VT 05403
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
ACM ROOF EDGE
12'-6"
T.O. SLAB
0'-0"
T.O. WINDOW OPENING
10'-0"
T.O. PARAPET
21'-8"
T.O. WINDOW OPENING
19'-0"
T.O. PARAPET
24'-9"
T.O. PARAPET
22'-11"
ACM ROOF EDGE
12'-6"
T.O. SLAB
0'-0"
T.O. WINDOW OPENING
10'-0"
T.O. PARAPET
21'-8"
T.O. WINDOW OPENING
19'-0"
T.O. PARAPET
24'-9"
T.O. PARAPET
22'-11"
1 WEST ELEVATION (SHELBURNE STREET)SCALE: 1/4"=1'-0"
2 NORTH ELEVATION (SWIFT STREET)SCALE: 1/4"=1'-0"
A-3
EXTERIOR ELEVATIONS
JPMORGAN CHASE BANK
720 Shelburne Road
1521451-00
08/23/2023
PROJECT
SEAL
SCALE
PROJECT NO.
DATE
DRAWING
IN CONSIDERATION OF RECEIVING DRAWINGS FROM TPG ARCHITECTURE LLP IN
AN ELECTRONIC FORM, THE RECIPIENT AGREES, TO THE FULLEST EXTENT
PERMITTED BY LAW, TO HOLD HARMLESS AND INDEMNIFY TPG ARCHITECTURE
LLP FROM AND AGAINST ALL CLAIMS, LIABILITIES, LOSSES, DAMAGES, AND
COSTS, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES, ARISING OUT OF,
OR IN ANY WAY CONNECTED WITH THE USE, RE-USE, MIS-USE, MODIFICATION,
OR MISINTERPRETATION OF THE MACHINE-READABLE INFORMATION PROVIDED
BY TPG ARCHITECTURE LLP UNDER THIS AGREEMENT.
TPG ARCHITECTURE, LLP
132 WEST 31ST STREET, 5TH FLOOR, NEW YORK, NY 10001
212.768.0800 | TPGARCHITECTURE.COM
31 PENN PLAZA
DOB PAGE
NYC DOB NO.
CAD FILE NO.
DWG NO.
SOUTH BURLINGTON
Burlington, VT 05403
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
TOTAL TRANSPARENT GLAZING PERCENTAGE (MINIMUM 75% REQUIRED): 83% (562 SQ.FT.)
TOTAL OPAQUE GLAZING PERCENTAGE: 17% (95 SQ.FT.)
PRIMARY STREET GLAZING PERCENTAGE (SHELBURNE ROAD)
MINIMUM REQUIRED ACROSS WIDTH
OF FACADE: 60%ACTUAL PROVIDED: 63.5%
SECONDARY STREET GLAZING PERCENTAGE (SWIFT STREET)
MINIMUM REQUIRED ACROSS WIDTH
OF FACADE: 40%ACTUAL PROVIDED: 76 %
T.O. SLAB
0'-0"
T.O. PARAPET
24'-9"
T.O. PARAPET
22'-11"
T.O. SLAB
0'-0"
T.O. WINDOW OPENING
10'-0"
T.O. WINDOW OPENING
19'-0"
T.O. PARAPET
24'-9"
T.O. PARAPET
22-11"
T.O. PARAPET
21'-8"
JPMORGAN CHASE BANK
720 Shelburne Road
1521451-00
08/23/2023
PROJECT
SEAL
SCALE
PROJECT NO.
DATE
DRAWING
IN CONSIDERATION OF RECEIVING DRAWINGS FROM TPG ARCHITECTURE LLP IN
AN ELECTRONIC FORM, THE RECIPIENT AGREES, TO THE FULLEST EXTENT
PERMITTED BY LAW, TO HOLD HARMLESS AND INDEMNIFY TPG ARCHITECTURE
LLP FROM AND AGAINST ALL CLAIMS, LIABILITIES, LOSSES, DAMAGES, AND
COSTS, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES, ARISING OUT OF,
OR IN ANY WAY CONNECTED WITH THE USE, RE-USE, MIS-USE, MODIFICATION,
OR MISINTERPRETATION OF THE MACHINE-READABLE INFORMATION PROVIDED
BY TPG ARCHITECTURE LLP UNDER THIS AGREEMENT.
TPG ARCHITECTURE, LLP
132 WEST 31ST STREET, 5TH FLOOR, NEW YORK, NY 10001
212.768.0800 | TPGARCHITECTURE.COM
31 PENN PLAZA
DOB PAGE
NYC DOB NO.
CAD FILE NO.
DWG NO.
SOUTH BURLINGTON
Burlington, VT 05403
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
A-4
EXTERIOR ELEVATIONS
1 EAST ELEVATION (PRIMARY PARKING)SCALE: 1/4"=1'-0"
2 SOUTH ELEVATION (FUTURE STORE)SCALE: 1/4"=1'-0"
SSSSSSSS
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UPUPUPUPUP
UP
UP
RIM = 207.51
D
D
D
D
D
D
OH
OH
OH
OH
OH
OH
OH
OH
OH
OH
21
3
214
2
1
6
21
7
213
21
4
21
221
1
21
5
21
6
214
2
1
2
213
2
1
1
21
6
21
7
21
3
21
5
2
1
2
2
1
0
21
421
3
21
1
21
2
21
0
21
0
21
2
21
1
21
3
21
5
2
1
7
2
1
6
21
4
20
8 20
9
21
8 21
9
21
0
21
1
21
321
2
21
6
21
4
21
821
7
21
0
20
9
209
21
0
21
1
21
2
20
8
N/F
GARY BOURNE
N/F
TKHS LLC
N/F
LEE THERESA M LIVING
TRUST, C/O DUFF AND PHELPS
N/F
GARY J. BOURNE
N/F
HANDY MOUNTAHA TRUST
1-STORY
BUILDING
2300 SQ. FT.
1-STORY
BUILDING
2812 SQ. FT.
1-STORY
BUILDING
6157 SQ. FT.
1-STORY
BUILDING
1-STORY
BUILDING
RAMP
PAVED DRIVE
PAVED DRIVE
PAVED DRIVE
SH
E
L
B
U
R
N
E
R
O
A
D
(
U
.
S
.
R
O
U
T
E
7
)
SWIFT STREET
SHED
D D D D D D D D D D D
D
D D
D D D
D D
D
D
WASTE OIL TANK
TRANSFORMER ON
CONCRETE PAD
D
D
D
D
D
11
6
'
±
13
7
'
±
122'±
14
0
'
±
118'±79'±
7'±45'±
12
5
'
±
56'±
76'±
99
'
±
239'±
1-STORY
BUILDING
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
GAS
METER
SC
E
SCE
SCE
ALL OVERHEAD
UTILITIES TO BE
REMOVED
ALL EXISTING
UNDERGROUND
UTILITIES TO BE
REMOVED
G
G
G
G
G
G
G
G
G G G G
G
G
G
G
G
G
G
G
UP
UP
UP
UP
UP
UP
UP
UG
UG
UG
UG
UPUPUPUP
UP
UP
UPUP
W
W
W
W
W W W W W W
N/F
764 SHELBURNE RD. LLC,
C/O GARY BOURNE
CONCRETE PAD WITH
TANK ACCESS WELLS
ALL EXISTING TREES
AND VEGETATION
TO BE REMOVED
B
B
B
B
SSSSSSSS
ASSUMED LOCATION OF
SMH IN INTERSECTION
OF SHELBURNE ROAD
AND SWIFT STREET
RIM = 215.5
CLAY 8" iIN (N) = 206.7
CLAY 10" iIN (E) =207.0
CLAY 10" iOUT(W) = 206.9
LIGHT TO REMAIN
AND BE PROTECTED
LIGHT TO REMAIN
AND BE PROTECTED
LIGHT TO BE REMOVED
GRAVEL DRIVE
GRAVEL
DRIVE
RIM = 209.0
18" RCP iIN(E) = 202.2
18" RCP iIN(S) =201.3
18" RCP IOUT(W) = 200.6
APPROX. LOCATION PER
DIGSAFE MARKINGS EX. 8" DI
WATER MAIN (TO BE VERIFIED)
APPROX. LOCATION
EX. 6" AC WATER MAIN
(TO BE VERIFIED)
CROSSWALK SIGNAL
POLE
LEGAL LOAD
LIMIT SIGNUTILITY
COVER
SILT FENCE TO
TERMINATE AT EDGE
OF CONSTRUCTION
ENTRANCES
SOIL STOCKPILE (TYP.)
LOCATION SHOWN FOR ILLUSTRATIVE
PURPOSES AND SUBJECT TO CHANGE
DURING CONSTRUCTION
EXISTING BUILDING,
CURBING, & ASSOCIATED
STRUCTURE TO BE REMOVED
EXISTING
BUILDING,
CURBING, &
ASSOCIATED
STRUCTURE TO BE
REMOVED
EXISTING BUILDING,
CURBING, & ASSOCIATED
STRUCTURE TO BE REMOVED
SILT FENCE TO BE INSTALLED
AROUND PERIMETER OF
PROJECT SITE
CONCRETE FOOTING
FOR ROUTE 7
OVERHEAD LANE
ASSIGNMENT SIGN
RIM = 207.9
SUMP = 203.1
18" RCP iOUT +/- 202.7
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
GAS STATION SIGN
ROAD WORK SIGN
RIM = 207.5
CLOGGED
RIM = 213.1
12" CMP iOUT(W) = 208.6
TO BE REMOVED
SILT FENCE TO BE INSTALLED PRIOR
TO PAVEMENT DEMOLITION
PROVIDE INLET
PROTECTION AROUND
ON SITE CATCH BASINS
(TYP.)
PROVIDE DIVERSION RIDGE
UPSLOPE OF CONSTRUCTION
ENTRANCE WHERE SITE IS
UPSLOPE OF CONNECTING
ROADWAY (SEE DETAIL)
PROVIDE DIVERSION RIDGE
UPSLOPE OF CONSTRUCTION
ENTRANCE WHERE SITE IS
UPSLOPE OF CONNECTING
ROADWAY (SEE DETAIL)
TO BE REPLACED
TO BE REMOVED
CHAINLINK CONSTRUCTION
FENCE TO BE INSTALLED
AROUND PERIMETER OF SITE AT
PROPERTY LINE PRIOR TO
COMMENCEMENT OF
DEMOLITION STABILIZED CONSTRUCTION ENTRANCE
24' WIDE X 30' LONG MINIMUM
CONSTRUCTION ENTRANCE (TYP.)
RIM = 210.8
15" RCP iIN(N) = 204.1
12" RCP iIN(E) =204.3
18" RCP iOUT(W) = 203.9
TO BE REMOVED
TO BE REMOVED
GRANITE CURB
TO BE REMOVED, STOCKPILED,
AND EVALUATED FOR REUSE
AS APPROPRIATE
ASPHALT CUT, TYP.
LIGHT TO BE REMOVED
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
0
Feet
Graphic Scale
20 40 60
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Demolition & EPSC
Plan
C1-02
03/01/2024
1" = 20'
22-523
CML
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
1 04/15/2023 CMLStaff Comments
REMOVAL NOTES:
1.CONTRACTOR SHALL CONTACT DIG-SAFE (811) AT LEAST 48 HOURS PRIOR TO ANY
EXCAVATION.
2.CONTRACTOR SHALL COORDINATE WITH THE OWNER/OWNER'S REPRESENTATIVE ON
ALL MATERIALS TO BE REMOVED AND RECYCLED/DISPOSED OF OFF SITE. ALL HANDLING
OF MATERIALS TO BE REMOVED, RECYCLED, OR DISPOSED OF MUST BE DONE SO IN A
SAFE, LEGAL MANNER, IN ACCORDANCE WITH ALL LOCAL, COUNTY, STATE, FEDERAL,
AND ANY OTHER APPLICABLE REGULATIONS.
2.DEMOLITION SHALL OCCUR AFTER IMPLEMENTATION OF EROSION CONTROL MEASURES
IN ACCORDANCE WITH APPLICABLE STATE PERMITS AND EROSION CONTROL PLANS.
3.ALL ITEMS REQUIRING REMOVAL SHALL BE REMOVED TO FULL DEPTH AND INCLUDE BASE
MATERIAL AND FOOTINGS OR FOUNDATIONS AS APPLICABLE UNLESS OTHERWISE
NOTED.
4.IF DISCREPANCIES EXIST BETWEEN THE PLANS AND SITE CONDITIONS, CONTRACTOR
SHALL NOTIFY THE ENGINEER AND/OR OWNERS REPRESENTATIVE FOR CLARIFICATION.
5.IN SOME CASES ABANDONED UTILITIES CAN REMAIN AT THE ENGINEER OR OWNER'S
DISCRETION.
6.EXISTING ITEMS INDICATED TO BE SALVAGED OR STOCKPILED SHALL BE CAREFULLY
REMOVED AND STORED AS DIRECTED BY THE OWNER/OWNER'S REPRESENTATIVE.
7.TREE, SHRUB, AND VEGETATION REMOVAL SHALL INCLUDE THE FILLING, CUTTING,
GRUBBING OUT OF THE ENTIRE ROOT SYSTEM AND SATISFACTORY OFF SITE DISPOSAL OF
ALL TREE, SHRUBS, STUMPS, VEGETATION, AND EXTRANEOUS DEBRIS PRODUCED
THROUGH THE REMOVAL OPERATIONS. FELL TREES IN SUCH A WAY AS TO NOT DAMAGE
ADJACENT BUILDINGS OR OTHER TREES TO BE SAVED.
8.CONTRACTOR SHALL STRIP AND STOCKPILE EXISTING TOPSOIL TO FULL DEPTH WITHIN
LIMIT OF GRADING BEFORE COMMENCING EXCAVATION AND GRADING OPERATIONS.
TOPSOIL SHALL NOT BE REMOVED FROM THE SITE, UNLESS APPROVED BY THE
OWNER/OWNER'S REPRESENTATIVE.
9.CONTRACTOR TO LOCATE AND ABANDON ALL EXISTING WATER SERVICES AT THE
CORPORATIONS. CLOSE THE CORPORATIONS, DISCONNECT THE SERVICE LINES, AND
WRAP THE SERVICE TAPS IN V-BIO POLYURETHANE.
GAS STATION REMOVAL NOTES
1.ALL DEMOLITION AND REMOVAL OF EXISTING FEATURES ASSOCIATED WITH THE PRIOR
GAS STATION USE SHALL ADHERE TO VT ENVIRONMENTAL REGULATIONS. THE
CONTRACTOR SHALL COORDINATE WITH THE OWNER AND ENGINEER REGARDING
REQUIRED ENVIRONMENTAL APPROVALS PRIOR TO DEMOLITION.
SITE PROTECTION NOTES:
1.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE INSIDE AND OUTSIDE THE LIMIT OF
WORK DUE TO THEIR CONTRACTOR OPERATIONS.
2.CONTRACTOR SHALL PROTECT AND SUSTAIN IN NORMAL SERVICE ALL EXISTING UTILITIES,
STRUCTURES, EQUIPMENT, ROADWAYS, AND DRIVES UNLESS OTHERWISE NOTED.
3.AT ALL LOCATIONS WHERE EXISTING PAVEMENT ABUTS NEW CONSTRUCTION, THE EDGE
OF THE EXISTING PAVEMENT SHALL BE SAW CUT TO A CLEAN SMOOTH AND SHARP EDGE
AND PROTECTED UNTIL ABUTTING MATERIALS ARE INSTALLED.
4.CONTRACTOR SHALL MAINTAIN NECESSARY TRAFFIC CONTROL DEVICES, DRUMS,
DELINEATORS, SIGNS, FENCES, AND BARRICADES IN ACCORDANCE WITH THE LATEST
EDITION OF THE NATIONAL MUTCD WITH VT SUPPLEMENT TO PROPERLY PROTECT WORK,
EQUIPMENT, PERSONS, AND PROPERTY FROM DAMAGE.
SITE PREPARATION NOTES:
1.CONTRACTOR SHALL CONTACT DIG-SAFE (811) AT LEAST 48 HOURS PRIOR TO ANY
EARTHWORK OR EXCAVATION.
2.PRIOR TO CONSTRUCTION, CONTRACTOR SHALL ARRANGE PRE-CONSTRUCTION
MEETING WITH THE ENGINEER, LANDSCAPE ARCHITECT, AND/OR OWNER/OWNERS
REPRESENTATIVE TO REVIEW THE PROJECT PLANS AND CONSTRUCTION SCHEDULE.
3.ALL EROSION PROTECTION & SEDIMENT CONTROL MEASURES SHALL BE IN PLACE PRIOR
TO ANY EARTH DISTURBING ACTIVITIES. REFER TO PROJECT PLANS, NOTES AND DETAILS.
4.CONTRACTOR SHALL COORDINATE ALL ADJUSTMENT OR ABANDONMENT OF UTILITIES
WITH THE RESPECTIVE UTILITY COMPANY.
D
D
D
D
D
D
OH
OH
OH
21
3
214
2
1
6
21
7
213
21
4
21
221
1
21
5
21
6
214
21
2
213
2
1
1
216
21
7
21
3
21
5
2
1
2
2
1
0
21
421
3
21
1
21
2
21
0
21
0
21
2
21
1
21
3
21
5
2
1
7
2
1
6
21
4
20
8 20
9
21
8 21
9
21
0
21
1
21
321
2
21
6
21
4
21
821
7
21
0
20
9
209
21
0
21
1
21
2
20
8
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB SB SB SB SB SB SB SB SB SB SB
SB
SB
SB
SBSB
SB
SB
SB
SB
SB
SB
SB
SB
1
0
'
1-STORY
BUILDING
1-STORY
BUILDING
SH
E
L
B
U
R
N
E
R
O
A
D
(
U
.
S
.
R
O
U
T
E
7
)
SWIFT STREET
D
D D D D D
D D D
DD
D
D
D
D
1-STORY
BUILDING
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
UP
UP
UP
UP
UP
UG
UG
UG
UG
SSSSSSSS
CROSSWALK SIGNAL
POLE
UTILITY
COVER
CONCRETE FOOTING
FOR ROUTE 7
OVERHEAD LANE
ASSIGNMENT SIGN
SO
L
.
#
3
-
7
5
"
BUILT-IN TPCONTROLS
D
D
D
D
D
D
D
D
LOT 1:
FINANCIAL
INSTITUTION
±3,350 SF
FFE 212.0
LOT 3: MULTIFAMILY
RESIDENTIAL
27 DU
FFE 217.0
BFE 207.0
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
RD
D
D
D
LOT 2: MIXED USE
1ST FLOOR: COMMERCIAL
2ND FLOOR: 3 DU
± 3,240 SF
FFE 212.0
D D D
D
D
D
DD
D
D
D
2
1
0
2
0
9
2
1
1
21
1
21
0
20
9
20
8
2
1
6
2
1
5
2
1
1
2
1
2
209
210
211
2
1
1
2
1
0
2
1
2
2
1
3
215
216
21
5
21
6
216.5
21
7
21
5
21
6
2
1
4
21
8
21
8
21
7
215
20
9
20
6
205.5
212
2
1
3
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
FD
FD
D
D
D
21
6
2
1
0
2
1
1
20
9
UP UP
UP
UP
2
1
4
21
5
210 211
212
2
1
3
21
2
2
1
5
21
3
21
4
21
2
21
5
212
212
D
D
D
2
1
4
W
S
UD
UD
UD
UD
UD
UD
2
1
4
POTENTIAL FUTURE
10' x 6' GENERATOR
LOCATION
10' x 12' TRANSFORMER
w/SCREEN FENCE IF REQ'D
BY GMP
(8) BIKE SPACES
ENCLOSED DUMPSTERPROPOSED 12' WIDE
CROSS LOT
CONNECTION
DROP OFF AREA
w/VEHICULAR PAVERS
MODULAR BLOCK RETAINING
WALL w/42" HIGH GUARDRAIL
STORMWATER TREATMENT
STRUCTURE (TYP.)
CONCRETE STAIRS
w/STAINLESS STEEL
HANDRAILS (TYP.)
MODULAR BLOCK
WALL (TYP.)
FLUSH CURB
(TYP.)
WOODEN CURVED
BACKLESS BENCH
(TYP.)
STAMPED CONCRETE
PAVEMENT
2' BRICK
PAVING
CONCRETE STAIRS
w/STAINLESS STEEL
HANDRAILS BOTH
SIDES (TYP.)
FLUSH CURB
(TYP.)
ADA SPACE
w/VEHICULAR
PAVERS
DETECTABLE
WARNING
MODULAR BLOCK
RETAINING WALL
(TYP.)
4' WOOD PRIVACY FENCE
RAISED PLANTER w/MODULAR BLOCK WALL
STAMPED CONCRETE PAVEMENT
WOODEN CURVED
BACKLESS BENCH
(TYP.)
STORMWATER TREATMENT
AREA (TYP.)
STAMPED CONCRETE
PAVEMENT
WOODEN CURVED
BACKLESS BENCH
(TYP.)
CONCRETE STAIRS
w/STAINLESS STEEL
HANDRAILS (TYP.)
MODULAR BLOCK
RETAINING WALL
(TYP.)
MODULAR BLOCK RETAINING
WALL w/42" HIGH GUARDRAIL
(2) BIKE SPACES
CONCRETE
SIDEWALK
MODULAR BLOCK
FREESTANDING WALL (TYP.)
WOODEN CURVED BACKLESS
WALL CAP BENCH
EXISTING SHELBRUNE
RD LIGHT FIXTURE TO
REMAIN, TYP.
PAVED BIKE PATH
SCULPTURE (TYP.)
APPROX. LOCATION
FOR REFERENCE ONLY
SIGN
(2) BIKE
SPACES
CONCRETE ADA
SPACE AND
ACCESS AISLE
LEGAL LOAD LIMIT SIGN
TO MATCH REMOVED SIGN
FLUSH CURB
(TYP.)
8' SIDEWALK
SNOW STORAGE AREA
2
0
9
21
3
214
2
1
6
21
7
SB SB SB SB SB SB SB SB
SB
SB
SB
SB
SB
D
D
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
D
D
D
D
21
1
21
0
20
9
20
8
21
8
21
7
21
5
20
9
20
6
205.5
W
W
W
W
FD
FD
212
21
2
212
212
UD
UD
UD
UD
UD
UD
POTENTIAL FUTURE
10' x 6' GENERATOR
LOCATION
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Layout & Materials
C2-01
03/01/2024
1" = 20'
22-523
PJM
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
GARAGE LEVEL ENTRANCE
SCALE: 1" = 20'
SEE ARCHITECTURAL
PLANS FOR
UNDERGROUND
PARKING LAYOUT
LAYOUT AND MATERIALS NOTES
1.THE DIMENSIONS SHOWN ON THE DRAWINGS SHOW DESIGN INTENT AND MUST
BE FIELD VERIFIED PRIOR TO PREPARATION OF SHOP DRAWINGS.
2.ALL LINES ARE PARALLEL, PERPENDICULAR, OR 45 DEGREES TO THE LINES FROM
WHICH THEY ARE MEASURED UNLESS OTHERWISE NOTED.
3.THE DIMENSIONS OF PAVEMENT AS SHOWN ON THE DRAWINGS ARE TO THE
CENTER LINE OF EACH TYPE OF JOINT EXCEPT WHERE PAVEMENT MEETS A
VERTICAL FACE; AT THIS LOCATION DIMENSIONS ARE TO THE VERTICAL FACE.
4.DIMENSIONS TO SITE OR BUILDING WALLS ARE TO THE OUTSIDE (OR EXPOSED)
FACE OF WALL UNLESS OTHERWISE NOTED.
5.EXPANSION JOINT FILLER AND SEALANT SHALL BE PLACED WHERE CONCRETE
PAVEMENT MEETS CURBING, WALLS OR OTHER VERTICAL ELEMENTS, INCLUDING
LIGHT BASES, HYDRANTS, BUILDINGS AND BUILDING COLUMNS, WALLS, STAIRS
AND AT OTHER CONDITIONS AS SHOWN ON THE DRAWINGS. CONTRACTOR
SHALL REQUEST THE PRESENCE OF THE LANDSCAPE ARCHITECT TO REVIEW THE
LAYOUT OF EXPANSION JOINTS PRIOR TO PLACING FINISHED WORK.
6.EXPANSION JOINTS SHALL BE LOCATED 25' - 30' O/C, MAX.
7.WHERE NEW PAVING OR EARTHWORK MEETS EXISTING PAVING OR EARTHWORK,
SMOOTHLY BLEND LINE OF EXISTING WITH NEW.
8.RESTORE EXISTING CONDITIONS AS NECESSARY IN ALL AREAS DISTURBED BY
THE CONSTRUCTION OF THIS PROJECT, INCLUDING, BUT NOT LIMITED TO,
RESETTING SITE IMPROVEMENTS, REPAVING AND SEEDING.
0
Feet
Graphic Scale
20 40 60
1 04/15/2024 LETStaff Comments
RIM = 207.51
D
D
D
D
D
D
OH
OH
OH
21
3
214
2
1
6
21
7
213
21
4
21
221
1
21
5
21
6
214
2
1
2
213
2
1
1
216
21
7
21
3
21
5
2
1
2
2
1
0
21
421
3
21
1
21
2
21
0
21
0
21
2
21
1
21
3
21
5 2
1
7
2
1
6
21
4
20
8 20
9
21
8 21
9
21
0
21
1
21
321
2
21
6
21
4
21
821
7
21
0
20
9
209
21
0
21
1
21
2
20
8
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB SB SB SB SB SB SB SB SB SB SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
1
0
'
1-STORY
BUILDING
1-STORY
BUILDING
SH
E
L
B
U
R
N
E
R
O
A
D
(
U
.
S
.
R
O
U
T
E
7
)
SWIFT STREET
D
D D D D D
D D
D
DD
D
D
D
D
1-STORY
BUILDING
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
UP
UP
UP
UP
UP
UG
UG
UG
UG
SSSSSSSS
ASSUMED LOCATION OF
SMH IN INTERSECTION
OF SHELBURNE ROAD
AND SWIFT STREET
RIM = 215.5
CLAY 8" iIN (N) = 206.7
CLAY 10" iIN (E) =207.0
CLAY 10" iOUT(W) = 206.9
APPROX. LOCATION PER
DIGSAFE MARKINGS EX. 8" DI
WATER MAIN (TO BE VERIFIED)
APPROX. LOCATION
EX. 6" AC WATER MAIN
(TO BE VERIFIED)
CROSSWALK SIGNAL
POLE
UTILITY
COVER
CONCRETE FOOTING
FOR ROUTE 7
OVERHEAD LANE
ASSIGNMENT SIGN
RIM = 207.9
SUMP = 203.1
18" RCP iOUT +/- 202.7
RIM = 210.8
15" RCP iIN(N) = 204.1
12" RCP iIN(E) =204.3
18" RCP iOUT(W) = 203.9
SO
L
.
#
3
-
7
5
"
BUILT-IN TPCONTROLS
D
D
D
D
D
D
D
D
LOT 1:
FINANCIAL
INSTITUTION
±3,350 SF
FFE 212.0
LOT 3: MULTIFAMILY
RESIDENTIAL
27 DU
FFE 217.0
BFE 207.0
DA 3 BIO
DA 1 BIO
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
RD
D
DA 7
BIOD
D
LOT 2: MIXED USE
1ST FLOOR: COMMERCIAL
2ND FLOOR: 3 DU
± 3,240 SF
FFE 212.0
D D D
D
D
D
DD
D
D
D
2
1
0
2
0
9
2
1
1
21
1
21
0
20
9
20
8
2
1
6
2
1
5
2
1
1
2
1
2
209
210
211
2
1
1
2
1
0
2
1
2
21
3
215
216
21
5
21
6
216.5
21
7
21
5
21
6
21
4
21
8
21
8
21
7
215
20
9
20
6
205.5
212
2
1
3
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
FD
FD
D
D
D
21
6
2
1
0
2
1
1
20
9
UP UP
UP
UP
2
1
4
21
5
210 211
212
2
1
3
21
2
2
1
5
21
3
21
4
21
2
21
5
212
212
D
D
D
2
1
4
W
S
UD
UD
UD
UD
UD
UD
2
1
4
SMH #2
RIM = 214.25
8" iIN = 205.46
6" iIN = 205.50
8" iOUT = 205.36
6" iOUT = 209.00SMH #3
RIM = 211.00
6" iIN (2) = 206.00
8" iOUT = 205.90
6" iOUT = 207.2
6" iOUT = 206.30
8" CLASS 52 DI
1.5" TYPE K COPPER
CONNECT TO EXISTING 8" DI PIPE
WITH 8"X8" TEE, (3) 8" GATE
VALVES SECURED WITH FOSTER
ADAPTERS, AND & THRUST BLOCK
1.5" WATER SERVICE
CONNECTION WITH
1.5" CURB STOP
POTENTIAL FUTURE
10' x 6' GENERATOR
LOCATION
FIRE PROTECTION HYDRANT
6"
C
L
A
S
S
5
2
D
I
8"X4" TEE, 8"X6" REDUCER, 6" GATE
VALVE, AND 4" GATE VALVE TO 4"
CLASS 52 DI DOMESTIC SERVICE
8"X6" TEE, 8" GATE VALVE,
AND 6" GATE VALVE TO 6"
CLASS 52 DI FIRE SERVICE
10' x 12' TRANSFORMER
w/SCREEN FENCE IF REQ'D
BY GMP
DMH2
RIM = 212.0
18" iIN (E) = 208.00
18" iIN (S) = 201.49
18" iOUT (W) = 201.39
FILTERRA INTERNAL BYPASS
BIOSCAPE 4'X6' MEDIA BAY
(TOP FLUSH WITH TOP OF CURB)
TOP OF SYSTEM = 214.25
CURB INLET = 213.75
8" iOUT = 210.42
4" FOOTING DRAIN
ASSUMED INV = 205.0
FILTERRA PEAK DIVERSION
6X10' MEDIA BAY
CURB INLET = 210.5'
12" iOUT ~ 207.17'
DMH4
RIM = 211.3
12" iIN (E) = 206.0
18" iIN (S) = 201.86
18" iOUT (N) = 201.76
OUTLET STRUCTURE 1
18" OVERFLOW GRATE = 215.80
12" iOUT = 212.0
OUTLET STRUCTURE 2
18" OVERFLOW GRATE = 210.50
16"WX3"H ORIFICE = 209.71
12" iOUT = 206.0
FILTERRA INTERNAL BYPASS
BIOSCAPE 4'X6' MEDIA BAY
6" iIN = 210.5
6" iOUT = 207.8'
OUTLET CONTROL STRUCTURE 4
RIM = 211.5
12" iIN (S) = 206.3
1"Ø ORIFICE = 206.3
WEIR ELEV. = 209.8
12" iOUT (W) = 206.3
FILTERRA INTERNAL BYPASS
BIOSCAPE 4'X6' MEDIA BAY
PARKING LOT CURB INLET = 208.4'
NW CORNER INLET (TOP OF
MEDIA) = 207.6'
8" iOUT ~ 205.2'
DMH 1
RIM = 210.5
12" iIN (NE) = 205.0
18" iIN (E) = 201.15
18" iOUT (NW) = 201.05
DMH 5
RIM = 211.85
12" iIN (E) = 202.39
6" iIN (FOOTING DRAIN) = 204.0
WITH FLAPPER VALVE AT END
8" iIN (W) = 202.39
18" iOUT (N) = 202.29
OUTLET STRUCTURE 3
18" OVERFLOW GRATE = 206.65
4"WX2"H ORIFICE = 205.85
12" iOUT = 202.50
DMH 6
RIM = 209.0
8" iIN (S) = 204.0
8" iOUT (E) = 203.9
EXTENDED DETENTION
THREE - 48" HDPE X 80'
INVERT = 206.3
FILTERRA INTERNAL BYPASS
BIOSCAPE 6'X6' MEDIA BAY
CURB INLET = 211.0
8" iOUT = 207.8'
CURB INLET = 208.4
CB1 (DEEP SUMP)
RIM = 213.60
12" iOUT = 210.30
DMH 3
RIM = 214.3
12" iIN (E) = 210.0
8" iIN (S) = 209.17
18" iOUT (W) = 208.30
TRENCH DRAIN AT ENTRANCE
TO GARAGE WITH DEEP SUMP
AT OUTLET (SEE DETAIL)
GRATE = 207.0
6" ROOF DRAIN
iOUT = 215.25
CB2 (DEEP SUMP)
WITH CURB INLET
INLET ELEV. = 210.90
8" iOUT = 209.106" ROOF DRAIN
PEASTONE
DIAPHRAGM (TYP.)
YARD DRAIN
RIM = 214.5
6" iOUT = 207.0
12" & 8" INV.'S = 209.00
CB2 (6' DIAMETER)
RIM = 209.0
EX. 18" iIN(E) = 202.2
EX. 18" iIN(S) = 201.3
NEW 18" iIN(SE) = 200.9
EX. 18" iOUT(W) = 200.6
8"
S
D
R
3
5
P
V
C
s=
0
.
0
0
4
f
t
.
/
f
t
.
CO
CO
INSTALL 2" RIGID
FOAM INSULATION
ABOVE SEWER WHERE
<5' COVER
SMH #1
CONTRACTOR TO VERIFY
ELEVATION OF EXISTING SEWER
AND REPORT TO ENGINEER
PRIOR TO CONSTRUCTION
RIM = 213.70
NEW 8" iIN = 205.20
EX. 10" iIN = 205.20±
EX. 10" iOUT = 205.10±
8"X6" TEE, 6" GATE VALVE,
AND THRUST BLOCK
FIRE PROTECTION HYDRANT
8"X4" TEE, 4" GATE VALVE,
AND THRUST BLOCK
4"
C
L
A
S
S
5
2
D
I
2
0
9
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Utility Plan
C3-01
03/01/2024
1" = 20'
22-523
CML
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
"I HEREBY CERTIFY THAT, IN THE EXERCISE OF MY REASONABLE
PROFESSIONAL JUDGMENT, THE DESIGN RELATED INFORMATION
SUBMITTED WITH THIS APPLICATION IS TRUE AND CORRECT AND
THE DESIGN INCLUDED IN THIS APPLICATION FOR A PERMIT
COMPLIES WITH THE VERMONT WASTEWATER SYSTEM AND
POTABLE WATER SUPPLY RULES." (REF. ENVIRONMENTAL
PROTECTION RULES CHAPTER 1 §1-306 (b)).
LAST REVISED 02/25/2020
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
0
Feet
Graphic Scale
20 40 60
NOTES:
1.CONTRACTOR TO FIELD VERIFY ELEVATIONS OF EXISTING PIPES AT CONNECTION
POINTS AND CROSSINGS. IF THE ACTUAL ELEVATIONS ARE DIFFERENT THAN SHOWN ON
SHEET C3-01 AND C3-02, THE CONTRACTOR SHALL NOTIFY THE ENGINEER.
2.PROVIDE 18" VERTICAL SEPARATION AT WATER/SEWER AND WATER/STORMWATER
UTILITY CROSSINGS.
3.PROVIDE RIDGED FOAM INSULATION OVER WATER AND SEWER WHERE INADEQUATE
COVER (<6' FOR WATER, <5' FOR SEWER). PROVIDE 2" FOAM INSULATION PER 1' OF
COMPROMISED COVER.
4.ALL WATER SYSTEM MATERIALS AND INSTALLATION PROCEDURES TO COMPLY WITH
CWD SPECIFICATIONS.
5.DI PIPE SHALL COMPLY WITH AND AWWA C151/ANSI A21.51. DI PIPE SHALL BE A
MINIMUM THICKNESS CLASS 52, BE CEMENT MORTAR LINED, AND BE GIVEN AN
EXTERIOR PETROLEUM ASPHALTIC COATING.
6.4" AND 6" DI PIPE SHALL HAVE NO LESS THAN TWO BRONZE WEDGES INSTALLED AT
EACH JOINT. 8" AND LARGER DI PIPE SHALL HAVE NO LESS THAN THREE BRONZE
WEDGES INSTALLED AT EACH PIPE JOINT.
7.V-BIO ENHANCED POLYETHYLENE PIPE ENCASEMENT IS REQUIRED FOR ALL DUCTILE
IRON PIPE INSTALLATION AND SHALL CONFORM TO CWD STANDARD AND THE
CURRENT AWWA C105/ANSI A21.5 STANDARD.
8.POLYETHYLENE ENCASEMENT SHALL PREVENT CONTACT BETWEEN THE PIPE OR FITTINGS
AND THE SURROUNDING BACKFILL AND BEDDING MATERIAL AND SHALL BE INSTALLED
AS OUTLINED IN SECTION 4.1 OF THE ABOVE AWWA/ANSI STANDARD. LUMPS OF CLAY,
MUD, CINDERS, ETC. ON THE PIPE SHALL BE REMOVED PRIOR TO INSTALLATION OF THE
POLYETHYLENE ENCASEMENT. DURING INSTALLATION, SOIL OR EMBEDMENT MATERIALS
SHALL NOT BE TRAPPED BETWEEN THE PIPE AND POLYETHYLENE. OVERLAP AND ENDS
SHALL BE SECURED WITH POLYETHYLENE ADHESIVE TAPE. ALL CUTS, TEARS, PUNCTURES,
OR DAMAGE TO THE POLYETHYLENE SHALL BE REPAIRED WITH POLYETHYLENE
ADHESIVE TAPE OR WITH A SHORT LENGTH OF POLYETHYLENE SHEET, WRAPPED
AROUND THE PIPE TO COVER THE DAMAGED AREA, AND SECURED IN PLACED.
BACKFILLING AROUND POLYETHYLENE WRAPPED PIPE SHALL BE IN ACCORDANCE
WITH ANSI/AWWA C600.
1 04/15/2024 CMLStaff Comments
D
D
D
D
D
D
OH
OH
OH
21
3
214
2
1
6
21
7
213
21
4
21
221
1
21
5
21
6
214
2
1
2
213
2
1
1
216
21
7
21
3
21
5
2
1
2
2
1
0
21
421
3
21
1
21
2
21
0
21
0
21
2
21
1
21
3
21
5 2
1
7
2
1
6
21
4
20
8 20
9
21
8 21
9
21
0
21
1
21
321
2
21
6
21
4
21
821
7
21
0
20
9
209
21
0
21
1
21
2
20
8
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB SB SB SB SB SB SB SB SB SB SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
1
0
'
1-STORY
BUILDING
1-STORY
BUILDING
SH
E
L
B
U
R
N
E
R
O
A
D
(
U
.
S
.
R
O
U
T
E
7
)
SWIFT STREET
D
D D D D D
D D
D
DD
D
D
D
D
1-STORY
BUILDING
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
G
UP
UP
UP
UP
UP
UG
UG
UG
UG
SSSSSSSS
SO
L
.
#
3
-
7
5
"
BUILT-IN TPCONTROLS
D
D
D
D
D
D
D
D
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
RD
D
D
D
D D D
D
D
D
DD
D
D
D
2
1
0
2
0
9
2
1
1
21
1
21
0
20
9
20
8
2
1
6
2
1
5
2
1
1
2
1
2
209
210
211
2
1
1
2
1
0
2
1
2
21
3
215
216
21
5
21
6
216.5
21
7
21
5
21
6
21
4
21
8
21
8
21
7
215
20
9
20
6
205.5
212
2
1
3
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
FD
FD
D
D
D
21
6
2
1
0
2
1
1
20
9
UP UP
UP
UP
2
1
4
21
5
210 211
212
2
1
3
21
2
2
1
5
21
3
21
4
21
2
21
5
212
212
D
D
D
2
1
4
W
S
UD
UD
UD
UD
UD
UD
2
1
4
INV. 12" STRM = 207.30±
INV. 8" SWR = 205.28
INV. 18" STRM = 208.21
INV. 6" SWR = 206.18
INV. 12" STRM = 210.38
INV. 6" WATER = 208.00
INV. 8" STRM = 209.81
INV. 8" SWR = 207.08INV. 12" STRM = 209.13
INV. 18" STRM = 201.32
INV. 12" STRM = 209.53
INV. 18" STRM = 201.51
INV. 8" STRM = 209.02
INV. 18" STRM = 201.31
INV. 8" SWR = 205.75
INV. 18" STRM = 201.64
INV. 12" STRM = 207.12
INV. 6" SWR = 206.28
INV. 12" STRM = 207.05
INV. 18" STRM = 201.88
INV. 6" STRM = 207.77
INV. 18" STRM = 202.16
INV. 8" WATER = 204.50±
INV. 18" STRM = 200.94
INV. 18" STRM = 208.12
INV. 8" SWR = 205.52
INV. 6" SWR = 207.80
INV. 6" WATER = 205.80
INV. 18" STRM = 209.82
INV. 8" SWR = 205.57
2
0
9
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Utility Crossing Plan
C3-02
03/01/2024
1" = 20'
22-523
CML
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
"I HEREBY CERTIFY THAT, IN THE EXERCISE OF MY REASONABLE
PROFESSIONAL JUDGMENT, THE DESIGN RELATED INFORMATION
SUBMITTED WITH THIS APPLICATION IS TRUE AND CORRECT AND
THE DESIGN INCLUDED IN THIS APPLICATION FOR A PERMIT
COMPLIES WITH THE VERMONT WASTEWATER SYSTEM AND
POTABLE WATER SUPPLY RULES." (REF. ENVIRONMENTAL
PROTECTION RULES CHAPTER 1 §1-306 (b)).
LAST REVISED 02/25/2020
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
0
Feet
Graphic Scale
20 40 60
NOTES:
1.CONTRACTOR TO FIELD VERIFY ELEVATIONS OF EXISTING PIPES AT
CONNECTION POINTS AND CROSSINGS. IF THE ACTUAL ELEVATIONS ARE
DIFFERENT THAN SHOWN ON SHEET C3-01 AND C3-02, THE CONTRACTOR
SHALL NOTIFY THE ENGINEER.
2.PROVIDE 18" VERTICAL SEPARATION AT WATER/SEWER AND
WATER/STORMWATER UTILITY CROSSINGS.
3.PROVIDE RIDGED FOAM INSULATION OVER WATER AND SEWER WHERE
INADEQUATE COVER (<6' FOR WATER, <5' FOR SEWER). PROVIDE 2" FOAM
INSULATION PER 1' OF COMPROMISED COVER.
1 04/15/2024 CMLStaff Comments
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Site Details
C8-01
03/01/2024
22-523
PJM
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
SD 010.1.4LAST REVISED 03/02/2021TRUDELL CONSULTING ENGINEERS
TYPICAL BITUMINOUS PAVEMENT
NOTES:
1.SUBBASE, SAND CUSHION AND SUBGRADE SHOULD BE CONSTRUCTED AND COMPACTED TO THE DIMENSIONS SHOWN IN
ACCORDANCE WITH VERMONT AGENCY OF TRANSPORTATION SPECIFICATIONS, STANDARD A-76. WHERE MORE STRINGENT
LOCAL ORDINANCES HAVE BEEN ADOPTED RELATIVE TO ROAD DIMENSIONS AND CONSTRUCTION, THEY SHOULD GOVERN.
2.COMPACT ALL SUBBASE MATERIALS TO 95% MAXIMUM DENSITY (STANDARD PROCTOR).
3.IF GROUNDWATER OR SOFT SPOTS ARE ENCOUNTERED CONTACT THE ENGINEER TO DISCUSS ADDED MEASURES SUCH AS
UNDERDRAIN. SLOPE SUBBASE TO UNDERDRAIN LOW POINTS.
SECTION
WEARING COURSE (TYPE III) (VAOT 406)
BASE COURSE (TYPE II) (VAOT 406)
CRUSHED GRAVEL (VAOT 704.05A FINE)
GRAVEL BASE (VAOT 704.04) OR
CRUSHED GRAVEL (VAOT 704.05A
COARSE)
MIRAFI 500X STABILIZATION FABRIC
INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS
6" SAND BORROW AND CUSHION TO BE
USED IN POORLY DRAINED SOILS OR
OVER BEDROCK FOR ROADS AND
SIDEWALKS (VAOT 703.03)
UNDISTURBED SUBGRADE
OR COMPACTED FILL
A
B
C
D
E
1" = 1'
DRIVEWAYS
E 6 66 66
RESIDENTIAL COMMERCIAL
1 1/2
6
18
2 1/2
4
12
N/A
2
3
18
6
COMMERCIAL
2
PRIVATEROADS
THICKNESS (INCHES)
PARKING LOTS
1
2
12
6
1-1/2
2-1/2
12
6
RESIDENTIAL
D
B
C
A
SD 010.1.9LAST REVISED 03/02/2021TRUDELL CONSULTING ENGINEERS
BITUMINOUS ASPHALT - VERTICAL BUTT JOINT
30" MIN
1 1/2" OVERLAY
PA
V
E
M
E
N
T
S
A
W
C
U
T
GRAVEL BASE
MATCH
EXISTING GRADE
APPLY TACK
COAT PRIOR
TO OVERLAY
1 1/2"
EXISTINGPROPOSED
BITUMINOUS
PAVEMENT
FINISHED GRADE
SD 030.1.1
1/2 " = 1'
LAST REVISED 03/08/2021TRUDELL CONSULTING ENGINEERS
TYPICAL CONCRETE SIDEWALK
SPECIFICATIONS:
1)1/2" EXPANSION/CONTRACTION JOINT WITH ASPHALT IMPREGNATED FIBER BOARD FILLER EVERY 50 FEET.
2)SCORED OR TOOLED JOINT (1" DEPTH OR 1/3 THE TOTAL DEPTH OF WALK) WITH A SEPARATION DISTANCE
EQUAL TO THE WIDTH OF THE SIDEWALK.
3)FULL-BREAK OR COMPLETE JOINT EVERY 20 FEET.
4)WHERE "HEAVY DUTY CONCRETE SECTION" IS CALLED OUT ON THE SITE PLAN, THE SIDEWALK IS TO BE 8" THICK.
5)IF WET OR UNSTABLE SOIL CONDITIONS EXIST CONTACT ENGINEER FOR ADDITIONAL MEASURES SUCH AS
UNDERDRAIN OR ADDITIONAL SUBBASE.
5"
6"6"VARIES
NOTE: DISTANCES ARE TYPICAL
AND MAY BE ALTERED FOR
SPECIFIC SITE CONDITIONS.
CONCRETE WEAR
COURSE (4000 PSI)
MINIMUM 18"
GRAVEL BASE
OWNER TO COORDINATE WITH OTHER DISCIPLINES
(ARCHITECT/STRUCTURAL ENGINEER) ON SIDEWALK WITHIN 5' OF
BUILDING. IN SOME CASES SIDEWALK WILL HAVE FROST WALL OR BE
PINNED TO FOUNDATION TO PREVENT FROST ACTION IN FRONT OF DOOR.
18"30"
#4 REBAR 30" O.C.
BOTH WAYS
SD 030.2.1LAST REVISED 03/03/2021TRUDELL CONSULTING ENGINEERS
WARNING TEXTURE
NOTES:
1.PER MUNICIPAL REQUIREMENTS PROVIDE CAST IRON
TRUNCATED DOME PAD.
2.SEE SITE PLAN FOR LOCATION.
ASPHALT
ASPHALT SURFACES SHALL BE COMPOSED OF OIL BASED BITUMEN. COAL TAR ASPHALT IS NOT ACCEPTABLE,
NOR WARRANTED. ASPHALT MUST CURE MINIMUM 20 DAYS PRIOR TO INSTALLATION TO INSURE PROPER
BONDING OF ALL SURFACES. THIS ALLOWS TENSILE STRENGTH PROPERTIES OF BOTH MATERIALS TO MORE
CLOSELY APPROXIMATE EACH OTHER. ANY ASPHALT AREAS REQUIRING DETECTABLE WARNING INSTALLATIONS
SHALL BE COMPACTED WITH VIBRATORY ROLLERS OR APPROVED COMPACTION EQUIPMENT IN ADDITION TO
STANDARD LOCAL CONDITIONS TO PROVIDE MAXIMUM COMPACTION OF ASPHALT ALLOWING THE
GREATEST ADHESION.
SEAL COAT
PRODUCT SHALL NOT BE PLACED ON ASPHALT OR COAL TAR SEALERS. IF SURFACE HAS BEEN SEALED, GRIND
ENTIRE AREA TO BE INSTALLED TO REMOVE ALL SEALERS.
CONCRETE
MINIMUM COMPRESSIVE STRENGTH 3000 PSI. CONCRETE MUST CURE FOR 15 DAYS PRIOR TO INSTALLATION TO
INSURE PROPER BONDING. ALL CONCRETE COLORING/ADDITIVES SHALL BE INTEGRAL, NOT SURFACE APPLIED.
ALL "SURFACE CURING" COMPOUNDS OR SEALERS SHALL BE REMOVED BY METHOD OF GRINDING ON ANY
CONCRETE THAT IS LESS THAN 6 MONTHS OLD BEFORE PRODUCTS ARE INSTALLED. SURFACE FINISH SHOULD BE
MEDIUM BROOM FINISH FOR MAXIMUM ADHESION.
SURFACES
ALL SURFACES TO BE CLEAN AND DRY. TRUNCATED DOMES AND ALL RELATED INSTALLED SURFACES TO BE
INSTALLED ACCORDING TO MANUFACTURERS SPECIFICATIONS. ALL DETECTABLE WARNING SURFACE
INSTALLATIONS SHALL BE AT MINIMUM, AT LEAST AS NON SKID AS THE SURROUNDING PEDESTRIAN SURFACES.
MIN.
CAST IRON TRUNCATED
DOME
DETECTABLE WARNING
DETAIL
G
ELEVATION
F
0.2"
G 1.40".90"
F .80".45"
E 1.50".65"
D
MAX.
2.40"
PLAN
1.60"
E
D
D
E
RAMP
EDGE OF PAVEMENT
NO CURB
CAST IRON TRUNCATED
DOMES. SEE SITE PLAN
FOR LOCATION(S).
24"
SIDEWALK
SD 030.2.2LAST REVISED 03/11/2021TRUDELL CONSULTING ENGINEERS
TYPICAL SIDEWALK LAYOUT
1/4"/FT.
5'
30"
5'
30
"
1/2" RADIUS TOOLED JOINT
NOTES:
1.SUBMIT SHOP DRAWINGS ON GRID PATTERN FOR REVIEW BY ENGINEER PRIOR TO CONSTRUCTION.
2.JOINT SPACING IS 5 FT. NORMAL SPACING WITH A MAXIMUM OF 8 FT. AND MINIMUM OF 2 FT. LINEAR
DIMENSIONS AND NOT INSIDE CORNERS.
3.#4 REINFORCING ON 30 INCH CENTERS BOTH DIRECTIONS IN CENTER OF SIDEWALK.
4.LAP BARS 30 BAR DIAMETERS.
5.EXPANSION JOINTS AT 20 FT. O.C..
6.SEE SITE PLAN FOR SIZE AND LOCATION.
5"
LAP BARS 30
BAR DIAMETERS
REINFORCING BARS (TYPICAL)TOOLED JOINT (TYPICAL)
EXPANSION JOINT
MATERIAL 20' O.C.REINFORCING BARS
SD 050.2.1LAST REVISED 03/11/2021TRUDELL CONSULTING ENGINEERS
BIKE RACK
36"
47
"
35
"
#4 REBAR 24"
O.C. BOTH WAYS
6"
18
"
6" PORTLAND CEMENT
PAD CLASS "A" CONCRETE
2X 0.25" X 12.75" ANCHOR RODS
18" CRUSHED STONE WRAPPED
IN 140N GEOTEXTILE FABRIC UNDISTURBED SOIL
6" P2 3/8" O.D.
GALVANIZED STEEL
SCHEDULE 40 PIPE WITH
POWDERCOAT FINISH
BLACK
NOTE:
SEE SITE PLAN FOR SIZE AND
LOCATION.
FINISHED GRADE
SD 050.2.2TRUDELL CONSULTING ENGINEERS
BIKE RACK LAYOUT
30"
O.C.
8'
30
"
24"
30
"
24"
16'-8"
CONCRETE PAD
BIKE RACK LOOP - INVERTED U
NOTES:
1.OVERALL CONCRETE PAD WIDTH WILL VARY BASED ON NUMBER OF LOOPS.
2.1 LOOP = 2 BICYCLE PARKING SPACES.
3.SEE SITE PLAN FOR SIZE AND LOCATION.
LAST REVISED 03/03/2021 SD 010.7.1LAST REVISED 03/09/2021TRUDELL CONSULTING ENGINEERS
APBA PARKING GUIDELINE PLAN VIEW
72"
24"
48"
(36" min)
96" RECOMMENDED TO OBSTRUCTION
(36" PREFERRED WHEN
ADJACENT TO AUTO
PARKING)
BIKE RACK
SD 050.1.1
1"=1'
LAST REVISED 03/10/2021TRUDELL CONSULTING ENGINEERS
REINFORCED CONCRETE PAD
CLASS A CONCRETE SLAB, BROOM FINISH
#4 REINFORCING BARS 12" O.C. BOTH WAYS,
3" CLEAR
18" CRUSHED STONE
COMPACTED SUBBASE
SIZE VARIES
SEE SITE PLAN
3/4" CHAMFER
(TYPICAL)
8"
140N GEOTEXTILE FABRIC
OR EQUAL AROUND STONE
FINISHED GRADE, SEE SITE PLAN FOR
FINISHED GRADE
NOTE:
CONTRACTOR TO COORDINATE KNOCKOUT LOCATIONS
IN CONCRETE FOR CONDUITS IF APPLICABLE.
UNDISTURBED SOIL
SD 020.X.XLAST REVISED 12/26/2023TRUDELL CONSULTING ENGINEERS
7.5
%
M
A
X
.
RAMP
SIDEW
A
L
K
1.5%
M
A
X
.
7.5%
M
A
X
.
RAMP
SID
E
W
A
L
K
1.5
%
M
A
X
.
12" MAX.
BACK CURB HEIGHT
SIDEWALK AND CURB RAMP DETAIL
PARALLEL RAMP BACK TREATMENT - SIDE CONFIGURATION
NOTE:
1.SIDEWALK AND CURB RAMP TO MATCH TECHNICAL REQUIREMENTS IN CHAPTER R3 OF THE
CURRENT U.S. ACCESS BOARD PUBLIC RIGHT-OF-WAY ACCESSIBILITY GUIDELINES.
1 04/15/2024 CMLStaff Comments
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Water Details
C8-04
03/01/2024
22-523
PJM
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
W 000.1.1LAST REVISED 02/04/2021TRUDELL CONSULTING ENGINEERS
TESTING WATER MAINS AND HYDRANTS
*ALL TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE TOWN ENGINEER OR PUBLIC WORKS DEPARTMENT IF
APPLICABLE OR PRIVATE OWNER/OPERATOR AND PROJECT ENGINEER (AS DESIGNATED BY OWNER). CONTRACTOR
SHALL PRE-TEST SUCCESSFULLY PRIOR TO CONTACTING PROJECT ENGINEER. THE PRE-TEST IS TO ENSURE PASSING
RESULTS PRIOR TO OFFICIAL TESTING OBSERVATION.
A.AFTER THE PIPE HAS BEEN LAID AND 7 DAYS AFTER THE CONCRETE THRUST BLOCKS AND ANCHORS HAVE BEEN
PLACED, THE WATER MAIN SHALL BE HYDROSTATICALLY TESTED ACCORDING TO THE LATEST EDITION OF THE
AWWA SPECIFICATION C-600, AND VERMONT PLUMBING RULES.
B.CONTRACTOR SHALL SUPPLY ALL NECESSARY APPARATUS TO PERFORM THE HYDROSTATIC TEST.
C. TEST PRESSURE SHALL BE 200 POUNDS PER SQUARE INCH OR 1.5 TIMES THE WORKING PRESSURE MEASURED AT
OR NEAR THE HIGH POINT IN THE SYSTEM, WHICHEVER IS GREATER. TEST SHALL BE A MINIMUM OF 2 HOURS IN
DURATION. TESTING ALLOWANCE SHALL BE DEFINED AS THE VOLUME OF WATER THAT MUST BE SUPPLIED INTO
THE NEWLY LAID PIPE OR ANY VALVED SECTION THEREOF TO MAINTAIN PRESSURE WITHIN 5 PSI (34.5 kPa) OF THE
SPECIFIED TEST PRESSURE AFTER THE PIPE HAS BEEN FILLED WITH WATER AND THE AIR HAS BEEN EXPELLED. THE
TESTING ALLOWANCE SHALL NOT EXCEED THE ALLOWABLE LEAKAGE (L) OR ELSE THE SECTION OF PIPE BEING
TESTED WILL BE CONSIDERED FAILED. TESTING ALLOWANCE SHALL NOT BE MEASURED BY A DROP IN PRESSURE IN
A TEST SECTION OVER A PERIOD OF TIME. REFER TO PIPE MANUFACTURERS RECOMMENDED TESTING
PROCEDURE INCLUDING PIPE STABILIZATION PRIOR TO START OF TEST.
D.THE PROJECT ENGINEER AND THE MUNICIPALITY SHALL BE CONTACTED 48 HOURS PRIOR TO TESTING.
E.ALL VALVES SHOULD BE VERIFIED AS BEING OPEN OR CLOSED AS APPROPRIATE FOR THE PORTION OF THE
WATER MAIN BEING TESTED.
F.ALLOWABLE LEAKAGE SHALL BE COMPUTED BY THE FORMULA: L=(S x D x √P)/148,000 WHERE L IS LEAKAGE IN
GALLONS PER HOUR, S IS THE LENGTH OF PIPE TESTED IN FEET, D IS THE NOMINAL DIAMETER OF THE PIPE IN
INCHES AND P IS THE AVERAGE TEST PRESSURE IN POUNDS PER SQUARE INCH DURING THE TEST.
G.REPLACE AND RETEST ANY WORK FOUND TO BE DEFECTIVE AFTER FAILED TEST AT NO EXPENSE TO OWNER AND
RETEST UNTIL SYSTEM PASSES
A.AFTER TESTING THE WATER MAINS, OPEN THE HYDRANT FULLY AND FILL WITH WATER. TO PREVENT CAPS FROM
BEING BLOWN OFF, VENT AIR FROM ONE OF THE CAPS WHILE IT IS BEING FILLED. WHEN ALL THE AIR HAS
ESCAPED, TIGHTEN THE CAP.
B.ALLOW THE PRESSURE TO BUILD UP TO MAIN LINE PRESSURE AND CHECK FOR LEAKAGE AT FLANGES, NOZZLES
AND THE OPERATING STEM. RECORD STATIC PRESSURE IN PSI.
C.FLOW HYDRANT AND RECORD FLOW RATE IN GPM AND RESIDUAL PRESSURE IN PSI. SUBMIT RESULTS TO PROJECT
ENGINEER.
D.CLOSE THE HYDRANT, REMOVE ONE NOZZLE CAP AND PLACE THE PALM OF YOUR HAND OVER THE OPENING.
DRAINAGE SHOULD CREATE A NOTICEABLE SUCTION. IF NO SUCTION OR HYDRANT DOESN'T HAVE DRAIN,
MANUALLY PUMP WATER OUT OF BARREL.
E.AT PROJECT ENGINEER DISCRETION, ASSIST WITH FLOW TESTING. ENGINEER TO RECORD STATIC AND RESIDUAL
PRESSURE AS WELL AS FLOW RATE.
TESTING WATER MAINS
TESTING HYDRANTS (IF APPLICABLE)
W 000.2.2LAST REVISED 02/04/2021TRUDELL CONSULTING ENGINEERS
DISINFECTION OF WATER SYSTEM
*ALL TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE TOWN ENGINEER OR PUBLIC WORKS
DEPARTMENT AND PROJECT ENGINEER (AS DESIGNATED BY OWNER).
A. PRIOR TO BEING PUT INTO SERVICE, WATER MAINS SHALL BE DISINFECTED ACCORDING TO THE
LATEST EDITION OF AWWA SPECIFICATION C-651. THE TABLET METHOD IN AWWA STANDARD 651 IS
NOT ACCEPTABLE.
B. THE NEW LINE SHALL BE FLUSHED AT A VELOCITY OF NOT LESS THAN 2.5 FEET PER SECOND (OPEN
2-1/2 INCH HYDRANT CONNECTION). FLUSH FOR A PERIOD DETERMINED BY THE PROJECT ENGINEER
FOR THE LENGTH OF MAIN TO BE DISINFECTED.
C. CHLORINATION SHALL BE ACCOMPLISHED BY INTRODUCING A SODIUM HYPOCHLORITE SOLUTION
FOR A RESULTANT CONCENTRATION OF GREATER THAN 25 PARTS PER MILLION OF FREE CHLORINE.
D. USING A NOZZLE AT EACH END HYDRANT, CONTROL THE RATE OF FLOW INTO THE NEW MAIN AND
PROPORTIONALLY FEED THE SODIUM HYPOCHLORITE SOLUTION INTO THE MAIN. AFTER THE SOLUTION
HAS REACHED ALL POINTS IN THE SYSTEM, CLOSE THE VALVE SUPPLYING WATER FROM THE EXISTING
MAIN AND THE END HYDRANTS. MAINTAIN THE HEAVILY CHLORINATED WATER IN THE MAIN FOR 24
HOURS DURING WHICH TIME ALL MAIN LINE VALVES SHOULD BE OPERATED. AFTER 24 HOURS THE
MINIMUM CHLORINE RESIDUAL MUST BE AT LEAST 10 PARTS PER MILLION.
E. FLUSH HEAVILY CHLORINATED WATER FROM THE LINE AND REFILL THE LINE FOR SERVICE (USE
CHLORINE DIFFUSER). TAKE AND SUBMIT TWO BACTERIOLOGICAL SAMPLES (TAKEN 24 HOURS APART)
OF THE WATER TO THE STATE OF VERMONT OR A STATE APPROVED TESTING LABORATORY. IF THE
RESULTS ARE UNSATISFACTORY, THE DISINFECTION PROCEDURE WILL BE REPEATED UNTIL
SATISFACTORY RESULTS ARE OBTAINED.
F. FINISHED WATER STORAGE STRUCTURES SHALL BE DISINFECTED IF APPLICABLE, IN ACCORDANCE
WITH CURRENT AWWA STANDARD C652. TWO OR MORE SUCCESSIVE SETS OF SAMPLES, TAKEN AT 24
HOUR INTERVALS, SHALL INDICATE MICROBIOLOGICALLY SATISFACTORY WATER BEFORE THE FACILITY
IS PLACES INTO OPERATION.
G. DISPOSAL OF HEAVILY CHLORINATED WATER FROM THE DISINFECTION PROCESS SHALL BE
DE-CHLORINATED OR OTHERWISE HANDLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE
VERMONT AGENCY OF NATURAL RESOURCES.
H. THE DISINFECTION PROCEDURE (AWWA CHLORINATION METHOD 3, SECTION 4.3 C652) WHICH
ALLOWS USE OF THE CHLORINATED WATER HELD IN THE STORAGE TANK FOR DISINFECTION PURPOSES
IS NOT RECOMMENDED. WHEN THAT PROCEDURE IS USED, IT IS REQUIRED THAT THE INITIAL HEAVILY
CHLORINATED WATER BE PROPERLY DISPOSED IN ORDER TO PREVENT RELEASE OF WATER WHICH
MAY CONTAIN VARIOUS CHLORINATED ORGANIC COMPOUNDS INTO THE DISTRIBUTION SYSTEM.
DISINFECTING WATER MAINS AND SYSTEMS
W 000.2.1LAST REVISED 03/08/2021TRUDELL CONSULTING ENGINEERS
CONTRACTOR'S CERTIFICATION REQUIRED
PRIOR TO THE DESIGN ENGINEER CERTIFYING THAT THE INSTALLATION HAS BEEN INSTALLED IN
ACCORDANCE WITH THE PERMITTED DESIGN, THE CONTRACTOR SHALL PROVIDE A
CERTIFICATION THAT THE WATER SYSTEM WAS INSTALLED AND TESTED IN ACCORDANCE WITH
THE APPROVED DESIGN PLANS. STATE PERMITS REQUIRE THERE SHALL BE NO DEVIATIONS
FROM THE APPROVED PLANS WITHOUT PRIOR APPROVALS. THE DESIGN ENGINEER SHALL BE
NOTIFIED AND ALLOWED TO OBSERVE THE CRITICAL PHASES OF CONSTRUCTION INCLUDING
ANY REQUIRED TESTS. LIKEWISE, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY
DEVIATIONS FROM THE APPROVED PLANS. SINCE THE DESIGN ENGINEER DOES NOT
CUSTOMARILY OBSERVE ALL PHASES OF THE WORK, OR ALL TESTING, HE MAY RELY ON THE
CONTRACTOR'S CERTIFICATION AS THE BASIS FOR FINAL CERTIFICATION. THE CONTRACTOR
SHALL THEREFORE SIGN AND RETURN A COPY OF THE FOLLOWING CERTIFICATION UPON
COMPLETION OF THE WORK:
"I HEREBY CERTIFY THAT I HAVE INSTALLED, PROPERLY TESTED, AND SUCCESSFULLY PASSED
THOSE TESTS, AND THE WATER SYSTEM(S) ARE BUILT IN ACCORDANCE WITH THE APPROVED
DESIGN PLANS AND APPLICABLE PERMIT CONDITIONS."
THE CONTRACTOR CERTIFICATION INCLUDES SUPPLIERS AND SUB-CONTRACTORS
CONTRACTOR NAME:
AUTHORIZED AGENTS NAME:
SIGNATURE: DATE:
NOTE ANY DEVIATIONS FROM APPROVED PLANS HERE:
NOTE: THE CERTIFICATION AND THE PROJECT ENGINEER'S SUBSEQUENT CERTIFICATION DOES NOT
VOID THE CONTRACTOR FROM REPAIR OR REPLACEMENT OF DISCREPANCIES DISCARDED AT A
LATER DATE. THE CONTRACTOR REMAINS RESPONSIBLE, INCLUDING CUSTOMARY GUARANTEE
AND WARRANTY PERIODS.
CONTRACTOR'S CERTIFICATION FOR WATER SYSTEM
1 04/15/2024 CMLStaff Comments
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Storm Details
C8-07
03/01/2024
22-523
SLH
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
SW 000.1.1LAST REVISED 03/08/2021TRUDELL CONSULTING ENGINEERS
CONTRACTOR'S CERTIFICATION FOR STORMWATER SYSTEM
CONTRACTOR'S CERTIFICATION REQUIRED
PRIOR TO THE DESIGN ENGINEER CERTIFYING THAT THE INSTALLATION HAS BEEN INSTALLED IN
ACCORDANCE WITH THE PERMITTED DESIGN, THE CONTRACTOR SHALL PROVIDE A
CERTIFICATION THAT THE STORMWATER SYSTEM WAS INSTALLED AND TESTED (IF APPLICABLE)IN
GENERAL ACCORDANCE WITH THE APPROVED DESIGN PLANS. STATE PERMITS REQUIRE THERE
SHALL BE NO SIGNIFICANT DEVIATIONS FROM THE APPROVED PLANS WITHOUT PRIOR
APPROVALS. THE DESIGN ENGINEER SHALL BE NOTIFIED AND ALLOWED TO OBSERVE THE
CRITICAL PHASES OF CONSTRUCTION INCLUDING ANY REQUIRED TESTS. LIKEWISE, THE DESIGN
ENGINEER SHALL BE NOTIFIED OF ANY DEVIATIONS FROM THE APPROVED PLANS. SINCE THE
DESIGN ENGINEER DOES NOT CUSTOMARILY OBSERVE ALL PHASES OF THE WORK, OR ALL
TESTING, HE WILL RELY ON THE CONTRACTOR'S CERTIFICATION AS THE BASIS FOR FINAL
CERTIFICATION. CRITICAL STORMWATER SYSTEM COMPONENTS TO BE CERTIFIED MAY INCLUDE,
BUT ARE NOT NECESSARILY LIMITED TO, SHAPES OF DRAINAGE SWALES, VOLUMES OF TREATMENT
PRACTICES, SLOPE OF DISCONNECT AREAS, AND OUTLET SIZE AND ELEVATIONS. THE
CONTRACTOR SHALL SHALL THEREFORE SIGN AND RETURN A COPY OF THE FOLLOWING
CERTIFICATION UPON COMPLETION OF THE WORK:
"I HEREBY CERTIFY THAT I HAVE INSTALLED, PROPERLY TESTED (IF APPLICABLE), AND
SUCCESSFULLY PASSED THOSE TESTS, AND THE STORMWATER TREATMENT AND COLLECTION
SYSTEM(S) ARE BUILT IN GENERAL ACCORDANCE WITH THE APPROVED DESIGN PLANS AND
APPLICABLE PERMIT CONDITIONS."
CONTRACTOR NAME:
AUTHORIZED AGENTS NAME:
SIGNATURE: DATE:
NOTE ANY DEVIATIONS FROM APPROVED PLANS HERE:
NOTE: THE CERTIFICATION AND THE PROJECT ENGINEER'S SUBSEQUENT CERTIFICATION DOES NOT
VOID THE CONTRACTOR FROM REPAIR OR REPLACEMENT OF DISCREPANCIES DISCOVERED AT A
LATER DATE. THE CONTRACTOR REMAINS RESPONSIBLE, INCLUDING CUSTOMARY GUARANTEE
AND WARRANTY PERIODS.
SSSSSSSS
OH
OH
OH
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB SB SB SB SB SB SB SB SB SB SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
1-STORY
BUILDING
1-STORY
BUILDING
SH
E
L
B
U
R
N
E
R
O
A
D
(
U
.
S
.
R
O
U
T
E
7
)
SWIFT STREET
1-STORY
BUILDING
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
UP
UP
UP
UP
UP
SSSSSSSS
GRAVEL DRIVE
GRAVEL
DRIVE
GRANITE CURB PR
I
V
A
C
Y
W
A
L
L
,
TY
P
.
D
D
D
D
D
D
D
D
DA 3 BIO
DA 1 BIO
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
RD
D
D
D
D D D
D
D
D
DDD
D
D
2
1
0
2
0
9
2
1
1
21
1
21
0
20
9
20
8
2
1
6
2
1
5
2
1
1
2
1
2
209
210
211
2
1
1
2
1
0
2
1
2
21
3
215
216
21
5
21
6
216.5
21
7
21
5
21
6
21
4
21
8
21
8
21
7
21
5
20
9
20
6
205.5
212
2
1
3
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
FD
FD
D
D
D
21
6
2
1
0
2
1
1
20
9
UP UP
UP
UP
2
1
4
21
5
210 211
212
2
1
3
21
2
21
5
21
3
21
4
21
2
21
5
212
212
D
D
D
2
1
4
W
S
UD
UD
UD
UD
UD
UD
2
1
4
2
0
9
(3) AF
(1) PS
(6) RR
(5) CAH
(6) SJL
(6) PVN
(1) NS
(9) PVN
(1) VT
(1) AB
(1) AAM
(11) CAK
(1) PS
(1) AAM
(10) JH
(12) CAK
(3) HAL
(7) JH
(32) CAK
(4) CAK
(7) JH
(4) CAK
(10) PVN
(21) SAW
(12) HAI
(2) CC
(22) JH
(1) CC
(6) MML
(16) RAG
(7) SJL
(3) PS
(5) CAR
(14) SBT
(1) IVM
(3) IVF
(3) IVF
(1) IVM(3) CS
(95) SH
(5) CSK (3) AAM
(3) VT
(1) AB
(73) HM
(1) CC (9) SAW
(1) HSS
(1) NS
(3) HAP
(45) HM
(3) RS
(3) BM
(1) HSS
(26) HS,HMA
INTERMIXED
IN GROUPS OF
5 OR MORE
(6) SAW
(8) PVN
(5) CAH
(5) CSK
(1) MML
(1) BM
(11) RAG
(1) HSS
(1) HSS
(1) HSS
(1) HSS
(1) HAL
(1) BM
(3) TM
(1) TM
(6) PVN
(6) HS
(1) HSS
(4) CS
(13) ADDA 7 BIO:
(20) AN
(14) IVE
(14) SH
(14) PVN
DA 1 BIO:
(25) AN
(15) AD
(30) EP
(20) IVE
(40) SS
(10) SH
(30) PVN
DA 3 BIO:
(20) AD
(25) EP
(15) IVE
(30) PVN
(40) SS
(75) SH
(36) HS, HMA
INTERMIXED IN
GROUPS OF 5
OR MORE
(1) MML
(4) SAW
(5) HAI
(8) HS
(1) HSS
(1) HSS
(1) AMS
(15) HS
(1) BM
(1) HSS
(1) HSS
(3) HAL
(8) HS(1) BM
(1) HAL
(1) HSS (1) HSS
(5) HS
(5) RAG
(6) HAI
(1) HS
(1) PS
(1) AAM (8)RAG
(1) AAM
(1) HAL
(16) RR
(4) RAG
(11) SBT
(1) NS
(6) SJL(48) CAK
(37) EPM
(1) MML
(9) RR
(6) SJL
(19) SBT
(3) RS
(3) AAM
(5) RS
(1) CC
(5) CS
(1) AF
(15) CSK
(8) CAH
(1) PS (67) EPM
(2) GT
(6) PVN
(33) SH
(16) RAG
(5) EPM
0
Feet
Graphic Scale
20 40 60
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
Landscape Plan
LA-1.0
03/01/2024
1" = 20'
22-523
LET
CMJ
LET
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
PARCEL ID: 1540-00760 SPAN: 600-188-10694
PROJECT LOCATION
PLANTING NOTES
1.IF DISCREPANCIES EXIST BETWEEN THE NUMBER OF PLANTS DRAWN ON THE PLANTING PLAN AND THE NUMBER OF PLANTS IN THE PLANT LIST, THE
PLANTING PLAN SHALL GOVERN.
2.ALL NEW PLANT MATERIAL SHALL CONFORM TO THE MINIMUM GUIDELINES ESTABLISHED FOR NURSERY STOCK PUBLISHED BY THE AMERICAN
ASSOCIATION OF NURSERYMEN, INC.
3.ALL NEW PLANTS TO BE BALLED AND BURLAPPED OR CONTAINER-GROWN, UNLESS OTHERWISE NOTED ON THE PLANT LIST.
4.THE CONTRACTOR SHALL SUPPLY ALL NEW PLANT MATERIAL IN QUANTITIES SUFFICIENT TO COMPLETE THE PLANTING SHOWN ON THE DRAWINGS.
5.ANY PROPOSED SUBSTITUTIONS OF PLANT SPECIES SHALL BE MADE WITH PLANTS OF EQUIVALENT OVERALL FORM, HEIGHT, BRANCHING HABIT, FLOWER,
LEAF, COLOR, FRUIT AND CULTURE, AND ONLY AFTER WRITTEN APPROVAL OF THE LANDSCAPE ARCHITECT.
6.ALL NEW PLANTS MAY BE TAGGED AND APPROVED BY THE LANDSCAPE ARCHITECT AT THE NURSERY PRIOR TO DIGGING OR DELIVERY TO THE SITE.
7.CONTRACTOR SHALL LOCATE AND VERIFY ALL EXISTING UTILITY LINES PRIOR TO PLANTING AND SHALL REPORT ANY CONFLICTS TO THE LANDSCAPE
ARCHITECT.
8.STAKE LOCATION OF ALL PROPOSED PLANTING FOR APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO THE COMMENCEMENT OF PLANTING.
9.NEW SHRUBS AND GROUND COVER SHALL BEAR THE SAME RELATIONSHIP TO GRADE AS IT BORE TO PREVIOUS GRADE. TREES SHALL BE SET 3" HIGHER
THAN PREVIOUS GRADE. NO TREES SHALL BE PLANTED BEFORE ACCEPTANCE OF ROUGH GRADING.
10.ALL PLANT BEDS SHALL RECEIVE TWO INCHES (3") OF BARK MULCH AS PER SPECIFICATIONS.
11.ALL EXISTING TREES TO REMAIN SHALL BE PROPERLY PROTECTED DURING CONSTRUCTION. PROTECTION TECHNIQUES SHALL BE REVIEWED AND
APPROVED BY THE LANDSCAPE ARCHITECT.
12.PRUNE TREES IN ACCORDANCE WITH THE SPECIFICATIONS SO THAT DISTURBED AREAS ARE RETURNED TO PRE-CONSTRUCTION CONDITIONS OR BETTER.
13.CONTRACTOR SHALL PROVIDE FULL DEPTHS OF LOAM AS NOTED ON DETAILS AND AS SPECIFIED, FOR ALL PLANTING.
14.ALL LAWN AREAS DISTURBED BY CONSTRUCTION OPERATIONS INSIDE AND OUTSIDE THE LIMIT OF WORK SHALL BE LOAMED AND SEEDED AS SPECIFIED.
15.SEE SPECIFICATIONS FOR TERMS OF PLANT MATERIAL ESTABLISHMENT PERIOD AND GUARANTEE.
16.PLANTINGS LOCATED ON PROPERTY LINES OR NEIGHBORING PROPERTY SHALL BE DONE ONLY AFTER AUTHORIZATION BY OWNER'S REPRESENTATIVE.
17.PROVIDE METAL TRELLIS AND RELEVANT HARDWARE FOR HYDRANGEA ANOMALA PETIOLARIS TO ESTABLISH ON WALL.
Plant Schedule
1
SOILS NOTE
1.SOILS IN PLANTING AREAS SHALL BE EVALUATED PRIOR TO PLANTING. IF SOILS ARE FOUND TO BE COMPACTED FROM PREVIOUS USE, SOILS SHALL BE
REMEDIATED THROUGH DECOMPACTION AND AMENDMENT BASED ON SOIL TESTING FROM A CERTIFIED SOILS LAB AND/OR REPLACED WITH LOAM
PLANTING SOIL AS APPROVED BY LANDSCAPE ARCHITECT.
1 04/15/2024 LETStaff Comments
D
D
D
D
D
D
OH
OH
OH
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB SB SB SB SB SB SB SB SB SB SB
SBSB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
SB
1-STORY
BUILDING
1-STORY
BUILDING
SH
E
L
B
U
R
N
E
R
O
A
D
(
U
.
S
.
R
O
U
T
E
7
)
SWIFT STREET
D
D
D D D
D D D D
D
D
D
D
1-STORY
BUILDING
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
UP
UP
UP
UP
UP
UG
UG
UG
UG
SSSSSSSS
GRANITE CURB
D D
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
UP UP
UP
UP
W
S
A
A
A
A
A A
A
A
AB
B
B
B
B
B
B
B
B
B
C
B
B B
B
B
B
B
MULTIFAMILY
RESIDENTIAL
27 DU
MIXED USE
1ST FLOOR: COMMERCIAL
2ND FLOOR: 3 DU
FINANCIAL
INSTITUTION
A
A
D
E
E
A
F
F
E
E
E
E
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
No. 8917
CIVILP
R
O
F
E
SSIONAL E N G I NEER
LICEN S E D
JENNI F E R ANN DESA
U
T
E
L
S
ST A T E O F VER
M
O
N
T
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
Lighting Plan
LI-01
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
PARCEL ID: 1540-00760 SPAN: 600-188-10694
03/01/2024
1" = 20'
22-523
PJM
CMJ
JAD
0
Feet
Graphic Scale
20 40 60
CALC ZONE #1
CHASE PARKING
SITE LIGHTING
LUMINAIRE SCHEDULE
SYMBOL LABEL QTY CATALOG NUMBER DESCRIPTION LAMP
A 30 white LEDs
B LED
NOTES:
1.AREA LIGHT AS SHOWN FOR PERMITTING AND INSTALLATION PURPOSES. BUILDING-MOUNTED FIXTURES
ARE SHOWN FOR PERMITTING PURPOSES ONLY. REFER TO ARCHITECTURAL PLANS FOR LIGHTING
INSTALLATION.
2.DISCREPANCIES BETWEEN THIS SHEET AND OTHER CIVIL, ELECTRICAL, OR ARCHITECTURAL PLANS
SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO INSTALLATION.
3.QUANTITIES AND CATALOG NUMBER SHOWN IN TABLE SHOULD BE VERIFIED BY ELECTRIC
CONTRACTOR PRIOR TO ORDERING.
4.POLE-MOUNTED FIXTURES TO BE SET WITH A 17-FT MOUNT HEIGHT ABOVE GROUND ELEVATION.
5.BUILDING-MOUNTED FIXTURES TO BE SET PER ARCHITECTURAL PLANS.
18
12
1.1 fc
1.8 fc
AVG. ILLUMINATION
(HORIZONTAL)
C LED1
Site Light
MANUFACTURER
Galleon Wall Luminaire - Type IV
1
N/A
2.8:1
19.7 fc
10.6 fc
MAX. POINT
ILLUMINATION
UNIFORMITY RATIO
(AVG:MIN)
0.0 fc
0.8 fc
MIN. POINT
ILLUMINATION
COOPER LIGHTING SOULTIONS
McGRAW-EDISON
(FORMERLY EATON)
WAC Lighting
Landscape Forms LE330-T4-HO-CLR
WS-W5516 A111914
GWC-SA1C-730-U-SL 4
Architectural Wall Light - Twilight
D N/A1
E LED6Chase Building CanopyFORMA LIGHTING
BULLET 127 - RECESSED
C-LITE C-CP-C-SQ-3L-40K-XXX
3499BB12-804032
ATM Canopy
MIXED-USE PARKING
SWIFT ENTRANCE
1.2 fc
1.4 fc
6.0:1
3.5:1
2.8 fc
2.8 fc
0.2 fc
0.4 fc
F LED2Pureform Bollard - Type VGardco Signify PBL-14-L-100-NW-G2 1 04/15/2024 AADStaff Comments