HomeMy WebLinkAboutZP-24-103 - 0027 Green Mountain Drive 4/24/20241 Rev 2019-11
CITY OF SOUTH BURLINGTON
ZONING PERMIT APPLICATION
PROPERTY Street Address: _________________________________________ Application No: _________________
[office use only]
Property Owner: __________________________________________________ Parcel Size: ___________________
Property Owner Mailing Address:___________________________________________________________________
APPLICANT: __________________________________________________________________________________
Applicant Mailing Address: _______________________________________________________________________
Applicant Email: ______________________________________________ Daytime phone: _________________
1. PROPOSED project including building dimensions (describe):
1a: IF NEW STRUCTURE
Building height (see Land Development Regulations Definition of Height): __________ft.
# of Bedrooms: ___________
The project will comply with the City of South Burlington “Regulation of Heating and Service Water Heating Systems
in New Buildings” ordinance: Yes No
2. RELATED Site Plan, Conditional Use, PUD, Subdivision, or Misc Approval Number (if applicable) 3. Present USE(S) of the property:
Single family home on its own parcel
Other (please state the USE per Land Development Regulations- retail, general office, multifamily residential, etc.):
_________________________________________________________________________________________________
4. List all present structure(s) on property (describe including dimensions or square footage of each): ___________________
___________________________________________________________________________________________________
5. Does the project include a proposed change of USE?
No (the property will still be used for the same purpose)
Yes
a. proposed changed or added USES per Land Development Regulations- retail, general office, multifamily
residential, etc.): ___________________________________________________________
b. proposed wastewater generation (GPD):
c. proposed PM Peak hour trip generation for entire property (in and out):
i. Land Use Code(s) Used, independent variables, calculations:
6. ESTIMATED total cost of improvements (materials and labor): $_______________________________
7. BUILDING footprint – i.e. size in sq. ft. of main floor of house and all attached and detached structures including enclosed
breezeways, garages, and sheds (describe): Existing:______________________ Proposed:_______________________
8. TOTAL impervious surfaces on site (i.e. Building footprint PLUS size in s.f. of driveways, patios, decks):
Existing:______________________ Proposed:_______________________
Complete the following only if the project involves changes to the dimensions of your building or other site changes (ie, not interior
renovations or roof / window / deck replacement)
27 Green Mountain Drive
Green Mountain Drive LLC
PO Box 790 Burlington VT 05452
Ted Samuelsen
PO Box 790 Burlington VT 05452
tsamuelsen@redstonevt.com 802.343.6809
65 unit multi family housing complex
$7000.00
Excavation from the existing mechanical room across a portion of the driveway for the installation of
(2) dual charging stations, to be installed in the parking lot. (Photo attached)
✔
(1) building approx. 26,000 sq ft building area
✔
ZP-24-103
2 Rev 2019-11
9. ATTACH SKETCH PLAN OR SITE PLAN 10. APPLICANT/OWNER CERTIFICATION
The undersigned property owner hereby consents to submission of this application and understands that if the application is
approved, the Zoning Permit and any attached conditions will be binding on the property.
_____________________________________________________________________ _________________________
Property Owner Signature PRINT NAME Date
The undersigned applicant hereby affirms that the information presented in this application is true, accurate and complete.
_____________________________________________________________________ _________________________
Applicant Signature PRINT NAME Date
OFFICE USE ONLY – ADMINISTRATIVE OFFICER ACTION – OFFICE USE ONLY
DATE Received: ___________________ FEE Received: $ _____________ Identification of zoning district: _______________
Project description: ______________________________________________________________________________________
SITE PLAN _____________________________________ ____________________________
Application # Approval Date
SUBDIVISION _____________________________________ ____________________________
Application # Approval Date
CONDITIONAL USE _____________________________________ ____________________________
Application # Approval Date
VARIANCE _____________________________________ ____________________________
Application # Approval Date
MISCELLANEOUS _____________________________________ ____________________________
Application # Approval Date
FINAL ADMINISTRATIVE OFFICER ACTION
ZONING PERMIT
□ APPROVED _________________________ ____________________________________________________________
Approval Date Administrative Officer’s Signature
Permit EFFECTIVE date _________________________ Permit EXPIRATION date ___________________________
CONDITIONS of Approval __________________________________________________________________________
□ Provided applicant copy of URBEC or VCBE Standards Handbook or □ Not Applicable
□ DENIED _________________________ _____________________________________________________________
Denial Date Administrative Officer’s Signature
REASON for DENIAL ______________________________________________________________________________________
Notice of Appeal Rights: Any interested person may appeal this decision by filing a written Notice of Appeal with the clerk of the Development Review
Board within fifteen [15] days of the date of this decision. The notice of appeal must be accompanied by a filing fee of $223.00.
This permit does NOT authorize commencement of any development activity approved by the permit until the permit takes effect as set forth
above. Site modifications and improvements made prior to this permit becoming effective may be subject to removal and site restoration if a timely
appeal is commenced.
NOTE: The applicant or permittee retains the obligation to identify, apply for, and obtain relevant state permits for this project. Call (802) 477-2241 to
speak with the regional Permit Specialist.
Ted Samuelsen 04/17/2024
Erik Hoekstra 4/17/2024
4/18/2024 43.00 C2
installation of EV chargers and related underground utility work
X
X
4/24/2024
5/10/2024 4/23/2025
S
219
222
223
218
222
221
219
224
220
224
224
222
222
224
220 218
220
RD
RD
ST
ST
ST
ST
215
215
212.5
216
ST
ST
RD
214
213
RD
RD
RD
RD
G
FD
ST
S
T
182 186
184
RD
RD
ST
224
218217216
216
216
215
RD
222
RD
RD
RD
RD
222
222
216
218 216
216
ST
ST
ST
223
2 22
221
220
219
218 217
216
222
224
219
218
220
221
220
220
217
219
220
22 4
222
218
220
190
192
198 200
210
ST212212
214
220
218
219
218
218
212.5 213
214 215
212211
222
214215
215214
215
215
214
214
215
215
214
213
212
216 216
216
216
216
215
215214
213
G
G
G
G
G
G
G
G
G
G
G
G
204
EXISTING OFFICE BUILDING
PROPOSED TRASH &RECYCLING BUILDING
W
W
W
W
W
W
W
W
W
W
G
G
G
G
E
T
E
T
S
S
S
S
S
S
E
T
W
W
NEW SMHRIM = 213.856" PVC IN = 205.606" PVC OUT = 205.50
6" SDR35 PVC SEWERINV = 211.50
6"SDR35PVC
S=0.024
6"SDR35PVC
S=0.066
TYPICAL 8" SDR35PVC ROOF DRAIN
NEW CB (24" SQ.)RIM = 219.008" IN = 215.0015" PE = 214.50
TYPICAL 8" SDR35 PVC ROOFDRAIN. SEE BUILDING PLANSFOR RISER LOCATIONS
STORM WATER
INFILTRATION
BASIN
E5
NEW ELECTRIC VAULT
NEW ELECTRIC SERVICE
NEW8"CL52DIWATER
MAINTAIN 5' SEPARATIONTO EXIST. DRYWELL
REMOVE EXIST. LIGHT POLEAND FIXTURES AND REPLACEWITH NEW POLE AND LEDFIXTURE (TYP. - 2 TOTAL)
NEW 8" X 8" TEE ANDNEW 8" GATE VALVE
EXISTING8"A.C.WATER
NEWELECTRICSERVICE
BARTLETT BROOK
STONE OUTFALLAND STONE SWALE
NEW CB (24" SQ.)RIM = 192.015" IN = 188.5015" OUT = 188.00
15" PE END SECTIONINV = 187.75
TREE REMOVAL AND GROUND DISTURBANCESHALL BE MINIMIZED DURING INSTALLATIONOF THE NEW STORM PIPING
12" PE END SECTIONINV = 212.50
NEW CB (24" SQ.)RIM = 222.508" IN = 215.0015" PE = 214.50
INSTALL CLAY DAMALONG SEWER PIPE
6" FOOTING DRAININV = 212.50
NEW CBRIM = 215.5012" IN = 213.1012" OUT = 213.10
APPROX.LIMITS
OFPAVEMENTREPLACEMENT
NEW 8" GATE VALVE
INSTALL FIBERGLASS MARKERSAT EACH NEW GATE VALVE
EXISTING DRYWELLEXIST. RIM = 215.79NEW RIM = 215.80 (NEW GRADE RINGS)NEW 12" PE IN = 213.0
REMOVE EXISTING CURB ANDINSTALL 4' GRANITE CURBTAPER WITH 5' OPENING FORRUNOFF TO ENTER ISLAND
12" PE WITH 90° ELBOW ANDGRATE. GRATE ELEV= 215.0
12"
PE
NEW HYDRANT WITH 6" GATEVALVE AND 6" CL52 DI PIPE
8"CL52DI
6"CL52DI
INSTALL 8"X6" REDUCERAFTER 8"X8"X6" HYDRANT TEE
DUCT BANK CONSISTS OF:(5) 4" SCH80 PVC - ELECTRIC(1) 4" SCH80 PVC - TELEPHONE(1) 4" SCH80 PVC - CATV(1) 4" SCH50 PVC - TEMPORARY(1) 2" SCH80 PVC - SITE LIGHTING(1) 2 .5" SCH80 PVC - TRASH BLDG
NEW CBRIM = 218.5012" OUT = 214.50
NEW CBRIM = 218.75(2) 12" IN = 214.1012" OUT = 214.10
S=0.005 198LFX12"PE
NEW CB(SIDE INLET)INLET = 215.2512" OUT = 214.35
5'WIDECONCRETESIDEWALK
NEW 8" PVCIN = 211.4OUT = 211.1
NEW GAS SERVICE - COORDINATEWITH VT GAS ON FINAL DESIGN OFSERVICE AND INSTALLATION
DISTURBANCE FOR TRENCH EXCAVATIONSHALL BE MINIMIZED AND ALIGNMENTSHALL AVOID EXISTING TREES NEW GAS SERVICE AND METERCONFIRM LOCATION WITHBUILDING PLANS
TYP. EXISTING LIGHTTO BE REMOVED
CONCRETETHRUST BLOCK
CONCRETETHRUST BLOCK
NEW5'WIDECONCRETE SIDEWALK
EXISTINGGATE VALVE
EXIST. CBRIM = 187.608" OUT = 183.6
8" PVCINV = 187.7
EXISTING DRYWELLRIM = 215.62
EXISTING DRYWELLRIM = 212.23
8"SDR35PVC6"
SDR35
PVC
15"
PERF.PE
15"PERF.PE
EXISTING8"ACSEWER
8"PVC
12"PE
12"PEX73LF
S=0.0034
CONCRETE CURB
CONCRETE CURB
CONCRETECURB
CONCRETE CURB
NEW GRANITECURB ISLAND
5'CONCRETE SIDEWALK
5'
SIDEWALK
SEE SEWER SERVICEPROFILE ON SHEET 9
GREENMOUNTAINDRIVE
50'WATER
SURFACEBUFFER
12"PE
X
145LF
S=0.0041
SEE INSET FOR STORMWATEROUTFALL AT BARTLETT BROOK
NEWGASSERVICE
N EW GAS SERVICE
E5
E5
E5
E5
SEWERC.O.
SEWERC.O.
THE CONTRACTOR SHALL COORDINATETHE SERVICE INTERRUPTION FOR THENEW WATERMAIN CONNECTION WORKWITH THE OWNER. THE EXCAVATIONSHALL BE KEPT DRY AT ALL TIMES, ANDTHE NEW TEE AND GATE VALVES SHALLBE CLEAN AND FREE OF ANY DEBRIS.
8"CL52DI
CONFIRM 6" DI WATER SERVICERISER WITH MECHANICAL PLANS
49'
57'
7.2'
21.1'
73.8'
9'
16.0'
8.5'
69.4'
24.2'66.7'
97.3'
96.5'
109.0'108.0'
102.2'
47.8'
46.2'
PROPOSED 65 UNIT
MULTI-FAMILY BUILDING1ST FLOOR = 226.00GARAGE = 215.50
69.25'
102.5'
101.0'
TELECOMM.MANHOLE
EXISTING STORMMANHOLE
EXISTING OUTFALL MANHOLE(DISCHARGE IS THROUGHSIDE OF STRUCTURE)
EXISTING STONE FILLTO REMAIN
BARTLETT
BROOK
REMOVE EXISTINGGEOTEXTILE AND PLACENEW 24"-36" ROCK BORROW
2R
UTILITY PLAN
25 & 27 Green Mountain Drive
South Burlington, Vermont
Date
Sheet number
Scale
Checked
Drawn
Design
Survey
Project No.
Lamoureux & DickinsonConsulting Engineers, Inc.14 Morse Drive, Essex, VT 05452802-878-4450www.LDengineering.com
Date Revision By
These plans shall only be used for the purpose shown below:
Sketch/Concept
PreliminaryFinal Local Review
Act 250 Review
Construction
Record Drawing
03-03-17
DJG
ABR
ABR
JMR
14001
EXIST. SMHRIM = 203.77NEW 6" PVC IN = 195.86EXIST. 8" AC INV=195.66
THE CONTRACTOR SHALLNOTIFY DIG SAFE® AT 811PRIOR TO ANY EXCAVATION.
1 inch = 30 ft.
(in feet)
GRAPHIC SCALE
30 0 15 30 60 120
1"=30'
220
W
G
E
T
S
G
218
RD
ST
E
W
S
LEGEND
CORE EXISTING MANHOLE AND INSTALLWATERTIGHT RUBBER BOOT. PROVIDESMOOTH TRANSITION BETWEEN NEW INLETPIPE AND EXISTING TROUGH
INSET - STORMWATEROUTFALL AT BARTLETT BROOK
SCALE: 1"=30'
NOTES:24"-36" ROCK BORROW - ROCK BORROWSHALL CONSIST OF BLASTED ROCK BROKENINTO VARIOUS SIZES THAT WILL FORM ACOMPACT EMBANKMENT WITH A MINIMUM OFVOIDS. THE MAXIMUM SIZE SHALL BE 36" INITS WIDEST DIMENSION AND THAT SIZEWHICH MAY BE INCORPORATED IN A 24"THICK LAYER OF ROCK EMBANKMENT.
THE LARGEST ROCKS SHALL BE PLACED ATTHE BOTTOM OF THE STONE FILL AT THEEDGE OF THE BROOK CHANNEL.
A PRECONSTRUCTION MEETING SHALL BEHELD ONSITE WITH THE ENGINEER PRIOR TOSTARTING ANY WORK ALONG THE BROOK.
THIS DRAWING WAS REVISED IN MARCH 2017 TO REFLECT THE RECORDHORIZONTAL LOCATION OF THE FOLLOWING ITEMS. ALL OTHER SITEIMPROVEMENTS ARE SHOWN IN THEIR DESIGN LOCATION:x WATER SERVICExSANITARY SEWER SERVICE & CLEANOUT