Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ZP-24-064 - 0133 Leo Lane 3/27/2024
ZP-24-064 03/14/2024 1,544.60 R1 PRD single family home 03/27/2024 04/12/2024 03/26/2025 (Acting) VIA HAND‐DELIVERY February 23, 2024 Betsy Brown South Burlington Planning and Zoning 180 Market Street South Burlington, VT 05403 Re: Zoning Permit Application 133 Leo Lane, South Burlington, VT 05403 Betsy, Further to Final Plat Permit SD‐22‐10A, enclosed please find a zoning permit application for 133 Leo Lane, South Burlington, Vermont 05403, Unit 16‐9 on the Final Plat/Site Plan submitted as part of SD‐22‐10A. Also enclosed please find: 1. A Water Allocation Application; 2. A Wastewater Allocation Application. 3. A wastewater Connection Application. 4. A site plan of the applicable area of the proposed home. 5. An architectural drawing showing compliance with plans proposed and permitted in SD‐ 22‐10A. Regarding the height of the proposed structure, please note that the preconstruction grade elevation (PCG) of the lot is 413.5 ft msl. The First Floor Elevation (FFE) is 414.6 ft msl. The PCG is calculated on the approved project plans by the project engineer. The height from FFE to the mid‐point of the tallest roof plane is 22.5’, as shown on the attached plan. The height of the building is the FFE, less the PCG, plus the height to the roof midpoint. This is 23.6’, below the height limit of the district and SD‐22‐10A. Please contact us with any questions or concerns. Sincerely, Brandon Secl, Estimator Property Owners Name:O'Brien Eastview Property Location:133 Leo Lane Amount:19,550.05 Payment Type:check #1639 Date:3/14/2024 Code Zoning Permit (New Residential)ZP-24-064 zp Recording fee 13.00$ plus addition/alteration cost 5.00$ per $1,000 project cost -$ OR: plus 2660 0.45$ per sq. ft. 1,197.00$ plus 1173 0.20$ per sq. ft. 234.60$ plus 2 50.00$ per bay 100.00$ After-the fact of 50% [no NOV] or 100% [NOV] -$ Zoning Permit Total 1,544.60$ Sewer Allocation Fee WWA-24-114 #204 249.15 g.p.d x 16.17$ 4,028.76$ Bartlett Bay x Airport Parkway Impact Fee Administrative Fee #248 per application $100.00 School Impact Fee #222S 4 bedroom home 12,353.51$ Recreation Impact Fee * #220 /unit -$ South Village Recreation Impact Fee #243 /unit -$ Road Impact Fee #221 $963.73 /unit 963.73$ Fire Impact Fee #203 /unit -$ Police Impact Fee #222 $496.45 /unit 496.45$ Dorset Street Waterline Fee #230 /unit -$ Sewer Connection Inspection WWC-24-18 ww 63.00$ per connection 63.00$ *Credit issued by City Council on 6/26/23 Total (Impact Fees + Permit) 19,550.05$ Planning & Zoning Invoice Residential Impact & Permit Fees garage bay(s) at Amount Due sq. ft building at sq. ft unfinished basement at IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 2/ 1 2 / 2 0 2 4 4 : 5 2 : 5 9 P M C : \ U s e r s \ c h a r l o t t e \ D o w n l o a d s \ S F -3 _ V 2 0 1 9 . r v t A0.000 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t COVER SHEET 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 SHEET INDEX SHEET NUMBER SHEET NAME MECHANICAL M1.100 BASEMENT ELECTRICAL PLAN - ELEVATION A FARMHOUSE ARCHITECTURAL A0.000 COVER SHEET A0.001 ARCHITECTURAL GENERAL NOTES A1.100 BASEMENT FLOOR PLAN - ELEVATION B CRAFTSMAN A1.110 MAIN FLOOR PLAN - ELEVATION B CRAFTSMAN A1.120 UPPER FLOOR PLAN - ELEVATION B CRAFTSMAN A1.200 EXTERIOR ELEVATIONS - ELEVATION B CRAFTSMAN A1.201 EXTERIOR ELEVATIONS - ELEVATION B CRAFTSMAN A1.300 ROOF PLAN - ELEVATION B CRAFTSMAN A1.400 BUILDING SECTIONS - ELEVATION B CRAFTSMAN A1.500 STAIR SECTION A1.600 FLOOR PLAN OPTIONS - ALL ELEVATIONS A1.700 OPT DAYLIGHT BASEMENT A1.701 OPT DAYLIGHT BASEMENT A2.100 BASEMENT FLOOR PLAN - ELEVATION A FARMHOUSE A2.110 MAIN FLOOR PLAN - ELEVATION A FARMHOUSE A2.120 UPPER FLOOR PLAN - ELEVATION A FARMHOUSE A2.200 EXTERIOR ELEVATIONS - ELEVATION A FARMHOUSE A2.201 EXTERIOR ELEVATIONS - ELEVATION A FARMHOUSE A2.300 ROOF PLAN - ELEVATION A FARMHOUSE A2.400 BUILDING SECTIONS - ELEVATION B AD.1 ARCHITECTURAL DETAILS AD.2 ARCHITECTURAL DETAILS AD.3 ARCHITECTURAL DETAILS AD.4 CABINET PLANS ELECTRICAL E1.100 BASEMENT ELECTRICAL PLAN - ELEVATION B CRAFTSMAN E1.110 MAIN FLOOR ELECTRICAL PLAN - ELEVATION B CRAFTSMAN E1.120 UPPER FLOOR ELECTRICAL PLAN - ELEVATION B CRAFTSMAN E2.100 BASEMENT ELECTRICAL PLAN - ELEVATION A FARMHOUSE E2.110 MAIN FLOOR ELECTRICAL PLAN - ELEVATION A FARMHOUSE E2.120 UPPER FLOOR ELECTRICAL PLAN - ELEVATION A FARMHOUSE E.1600 OPT FINISHED BASEMENT ELECTRICAL STRUCTURAL S-0.1 GENERAL NOTES S-0.2 GENERAL NOTES S-0.3 GENERAL NOTES S-0.4 TYPICAL DETAILS S-0.5 TYPICAL DETAILS S-0.6 TYPICAL DETAILS S-0.7 TYPICAL DETAILS S-0.8 TYPICAL DETAILS S-0.9 TYPICAL DETAILS S-0.10 TYPICAL DETAILS S-0.11 TYPICAL DETAILS S-0.12 TYPICAL DETAILS S-1.0 FOUNDATION ELEVATION A S-1.1 FOUNDATION ELEVATION B S-2.0 FRAMING ELEVATION A S-2.1 FRAMING ELEVATION A S-2.2 FRAMING ELEVATION B S-2.3 FRAMING ELEVATION B S-2.4 OPTIONAL BASEMENT PLANS ALL ELEVATIONS S-3.0 SHEARWALL ELEVATION A S-3.1 SHEARWALL ELEVATION A S-3.2 SHEARWALL ELEVATION A S-3.3 SHEARWALL ELEVATION B S-3.4 SHEARWALL ELEVATION B S-3.5 SHEARWALL ELEVATION B TOTAL NUMBER OF SHEETS: 57 AREA SCHEDULE - STANDARD AREA NAME AREA ELEVATION A MAIN FLOOR LIVABLE 1299 SF UPPER FLOOR LIVABLE 1361 SF LIVABLE 2660 SF 2-CAR GARAGE 431 SF PORCH 97 SF DECK 111 SF UNFINISHED BASEMENT 1173 SF NON-LIVABLE 1812 SF ELEVATION A 4472 SF ELEVATION B MAIN FLOOR LIVABLE 1299 SF UPPER FLOOR LIVABLE 1358 SF LIVABLE 2657 SF 2-CAR GARAGE 476 SF PORCH 127 SF DECK 111 SF UNFINISHED BASEMENT 1173 SF NON-LIVABLE 1887 SF ELEVATION B 4544 SF AREA SCHEDULE - OPTIONS AREA NAME AREA OPT. FINISHED BASEMENT FINISHED BASEMENT 560 SF UNFINISHED 558 SF TOTAL 1118 SF Elevation A -Craftsman Elevation B -Farmhouse Hillside at O'Brien Farm -Village Green Hilltop Single Family South Burlington, Vermont UP 1 5 R . A-2 A1.400 A-1 A1.400 5' - 0"10' - 0"17' - 0"5' - 0"21' - 0" 58' - 0" 2' - 4"16' - 4"2' - 4" 35 ' - 0 " 1' - 0 " 35 ' - 0 " 2' - 0 " 17 ' - 2 " 4' - 0 " 4' - 0 " 11' - 0"16' - 0" 10 ' - 1 0 1 / 2 " 10 " 5' - 0 " 1' - 0 " 001 10 " 10" 10" 10"10" 10 " UNEXCAVATED 8' -9" CLG MECHANICAL UNEXCAVATED AI R H A N D L E R 8' -9" CLG UNFINISHED BASEMENT HR V 58' - 0" 21' - 0"14' - 0"23' - 0" 12' - 6"8' - 6"3' - 6"10' - 6"23' - 0" 2' - 0 " 3' - 4 1 / 2 " 12 ' - 1 1 1 / 4 " 10 ' - 8 1 / 4 " 5' - 0 " 7' - 0"7' - 0" 19' - 4" 8' - 0 " 8' - 0 " 10"14' - 6"4' - 4 1/2"17' - 3 1/2"10" 5' - 0 " 11 ' - 0 " 10 ' - 1 0 " 3' - 6 " 10 " 15 ' - 3 1 / 2 " 3050 DH (2) 3068 FR DR (TEMP) 1 A1.500 010 10" 4 1/2" 3' - 1 1/2"3 1/2"52' - 6 1/2"10" 018 016 2 A1.500 004 8" 10 " 10" 10 " 10" 10 " 21068 STORM SUMP 21 0 6 8 WH 7' - 8 1 / 4 " IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.100 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t BASEMENT FLOOR PLAN - ELEVATION B CRAFTSMAN AREA SCHEDULE - STANDARD - ELEV A AREA NAME AREA ELEVATION A MAIN FLOOR LIVABLE 1299 SF UPPER FLOOR LIVABLE 1361 SF LIVABLE 2660 SF 2-CAR GARAGE 431 SF PORCH 97 SF DECK 111 SF UNFINISHED BASEMENT 1173 SF NON-LIVABLE 1812 SF ELEVATION A 4472 SF GENERAL FLOOR PLAN NOTES • MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) • WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. • PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. • ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. • PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. • SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. • PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. • ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) • ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) • CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. • ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. • ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. • FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. SCALE: 1/4" = 1'-0" Basement Plan -Elevation A CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. FLOOR PLAN KEYNOTES 001 DROP TOP OF FOUNDATION AT OVERHEAD GARAGE DOOR. 004 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS UNDER ACCESSIBLE ENCLOSED STAIRS. 010 HANDRAIL. 016 LINE OF DECKING ABOVE. 018 3" RIGID INSULATION. · · · · · FOUNDATION PLAN NOTES TYPICAL CONSTRUCTION ASSEMBLIES S-1.0PLAN SF 3 JOB NO:DRAWN: RE V I S I O N S IS S U E D A T E : PROJ MGR:CHECKED: 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 Hi l l s i d e a t O ' B r i e n F a r m SF210303.00 JM JCTK, JPC, MR So u t h B u r l i n g t o n , V e r m o n t Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y 8- 1 0 - 2 0 2 3 SCALE: 1/4" = 1'-0" FORMING PLAN - ELEVATION "A" DN DN UP 16 RISERS DN 1 5 R I S E R S A-2 A1.400 A-1 A1.400 2' - 9"2' - 3" 5' - 0"11' - 0"16' - 0"5' - 0"21' - 0" 2' - 6"16' - 0"2' - 6" 58' - 0" 3068 2' - 0 " 31 ' - 0 " 1' - 0 " 5' - 0 " 34 ' - 0 " 16080 OGD 2040 FX 2 -3060 DH 2040 DH TEMP 2040 DH 5' - 6"5' - 6" PORCH 3010 FX ABV. 4' - 4 " 1' - 8 " 6' - 0 " 35 ' - 0 " 139 138 4' - 0 " w/ 126 130130 2' - 0 " 4' - 0 " OPT OPT 21 ' - 4 " 15 ' - 4 " 12 ' - 1 0 " 3' - 1" 2' - 6"8' - 9"6' - 8" P.O. (2 ) 2 0 6 8 30 6 8 S C 21 0 6 8 3060 DH 3060 DH TEMP.OPT. 3060 DH 20 3 0 F X TE M P . DECK 2-CAR GARAGE O.E. FAMILY DINING KITCHEN STUDY POWDER 2-STORY CLG FOYER M.K. 3060 DH (TEMP) 3060 DH (TEMP) 27 ' - 0 " 2' - 0 " 7' - 1 0 " 3' - 1 0 1 / 2 " 15 ' - 3 1 / 2 " 1' - 9 1 / 2 " 2' - 1 " 12 ' - 1 0 " 2' - 5 1 / 2 " 4' - 10 1/2"4' - 10 1/2"2' - 11"2' - 11 1/2"4' - 0 1/2"4' - 0 1/2"2' - 11 1/2"3' - 10 1/2"6' - 7 1/2" 2868 8' - 0 " 21' - 0"14' - 0" 58' - 0" 5068 BP 26 6 8 8' - 0 " 6060 FX 3010 FX ABV.3068 FR DR (TEMP) 3' - 1 1 1 / 2 " 3' - 1 0 1 / 2 " 18 ' - 8 1 / 2 " 5 1 / 2 " BENCHDROP ZONE OPT. 3060 DH 20 3 0 F X 9' - 2 1 / 2 " 3' - 5 1 / 4 " 3' - 4 3 / 4 " 4' - 8 " 4' - 4"3 1/2"32' - 4 3/4"3 3/4"5 1/2" 4' - 6 1/2"15' - 8" 7' - 11 3/4"9 1/4" 3' - 6 1 / 2 " 2' - 6 1 / 2 " 6' - 0 " 2' - 9 " 3' - 1 0 1 / 2 " 19' - 9" 110112 104 101 102 10 3 10 8 109 108108 108 122 3' - 10 1/2" 3 1/2" 10"29' - 1"7' - 4"5 1/2" 12 2 10 7 131 131 OP T . 2x6 WALL 1 A1.500 10 9 5' - 7 1/2"8' - 9 1/2"1' - 1 1/2"5' - 0" 1' - 5 " 5' - 8 " 9" 124 129 127 128 133 123 2030 FX 145 2- S T R Y CL G 9' - 0 " CL G 9'-0" CLG 2-STRY CLG 131 131 6' - 0 " 2 A1.500 23' - 0" 109 107 10 7 21080 152 150 11 1/2" 9 1/4" 9 1 / 4 " 2' - 1 " 8' - 5 1 / 4 " 15' - 2 1/2" 6' - 10 1/2" 2' - 0 " 7' - 1 " 5' - 1" 2' - 1" 4' - 8 1/2" 7' - 1 " 10' - 1" 5' - 0"2' - 4 1/2" 2' - 5 1/2"5' - 10 1/2" OP T . OP T . CARPET VINYL TILE HARDWOOD LVP CARPET VINYL TILE HARDWOOD LVP CARPET VINYL TILE HARDWOOD LVP IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.110 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t MAIN FLOOR PLAN - ELEVATION B CRAFTSMAN SCALE: 1/4" = 1'-0" Main Floor Plan -Elevation A AREA SCHEDULE - STANDARD - ELEV A AREA NAME AREA ELEVATION A MAIN FLOOR LIVABLE 1299 SF UPPER FLOOR LIVABLE 1361 SF LIVABLE 2660 SF 2-CAR GARAGE 431 SF PORCH 97 SF DECK 111 SF UNFINISHED BASEMENT 1173 SF NON-LIVABLE 1812 SF ELEVATION A 4472 SF GENERAL FLOOR PLAN NOTES • MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) • WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. • PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. • ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. • PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. • SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. • PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. • ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) • ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) • CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. • ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. • ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. • FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. FLOOR PLAN KEYNOTES 101 SINK W/ GARBAGE DISPOSAL. 102 DISHWASHER. 103 REFRIGERATOR. 104 RANGE W/ HOOD. 107 PANTRY SHELVES PER BUILDER SPEC. 108 BASE CABINETS. 109 UPPER CABINETS. 110 WATER CLOSET. 112 PED. SINK. 122 ROD & SHELF. 123 ATTIC ACCESS. 124 HANDRAIL. 126 LINE OF OVERHEAD GARAGE DOOR IN OPEN POSITION. 127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD IN GARAGE AS REQUIRED BY CODE. 128 SLOPE GARAGE FLOOR 1/8" PER FOOT TOWARD GARAGE DOOR OPENING. 129 LINE OF FOUNDATION BELOW. 130 LINE OF SOFFIT ABOVE (REFER TO EXTERIOR ELEVATIONS FOR HEIGHTS AND DETAILS). 131 GYPSUM BOARD OPENING 8'-0" AT MAIN FLOOR & 7'-0" AT UPPER FLOOR. 133 LINE OF FRAMING ABOVE. 138 EXTERIOR GUARDRAIL W/ BALLUSTERS TO BE SPACED SUCH THAT 4" SPHERE CANNOT PASS BETWEEN BALUSTERS. 139 MASONRY WAINSCOT. 145 SHELF AT FINISH FLOOR LEVEL. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 152 TOWEL RING 48" A.F.F. 2x10 WALL DN UP 16 RISERS DN 1 5 R I S E R S A-2 A1.400 A-1 A1.400 2' - 9"2' - 3" 5' - 0"11' - 0"16' - 0"5' - 0"21' - 0" 2' - 6"16' - 0"2' - 6" 58' - 0" 3068 2' - 0 " 31 ' - 0 " 1' - 0 " 5' - 0 " 34 ' - 0 " 16080 OGD 2040 FX 2 -3060 DH 2040 DH TEMP 2040 DH 5' - 6"5' - 6" PORCH 3010 FX ABV. 4' - 4 " 1' - 8 " 6' - 0 " 35 ' - 0 " 139 138 4' - 0 " w/ 126 130130 2' - 0 " 4' - 0 " OPT OPT 21 ' - 4 " 15 ' - 4 " 12 ' - 1 0 " 3' - 1" 2' - 6"8' - 9"6' - 8" P.O. (2 ) 2 0 6 8 30 6 8 S C 21 0 6 8 3060 DH 3060 DH TEMP.OPT. 3060 DH 20 3 0 F X TE M P . DECK 2-CAR GARAGE O.E. FAMILY DINING KITCHEN STUDY POWDER 2-STORY CLG FOYER M.K. 3060 DH (TEMP) 3060 DH (TEMP) 27 ' - 0 " 2' - 0 " 7' - 1 0 " 3' - 1 0 1 / 2 " 15 ' - 3 1 / 2 " 1' - 9 1 / 2 " 2' - 1 " 12 ' - 1 0 " 2' - 5 1 / 2 " 4' - 10 1/2"4' - 10 1/2"2' - 11"2' - 11 1/2"4' - 0 1/2"4' - 0 1/2"2' - 11 1/2"3' - 10 1/2"6' - 7 1/2" 2868 STORAGE 8' - 0 " 21' - 0"14' - 0" 58' - 0" 2068 26 6 8 8' - 0 " 6060 FX 3010 FX ABV.3068 FR DR (TEMP) 3' - 1 1 1 / 2 " 3' - 1 0 1 / 2 " 18 ' - 8 1 / 2 " 5 1 / 2 " BENCHDROP ZONE OPT. 3060 DH 20 3 0 F X 9' - 2 1 / 2 " 3' - 5 1 / 4 " 3' - 4 3 / 4 " 4' - 8 " 4' - 4"3 1/2"32' - 4 3/4"3 3/4"5 1/2" 4' - 6 1/2"15' - 8" 7' - 11 3/4"9 1/4" 3' - 6 1 / 2 " 2' - 6 1 / 2 " 6' - 0 " 2' - 9 " 3' - 1 0 1 / 2 " 2' - 3"17' - 6" 110112 104 101 102 10 3 10 8 109 108108 108 122 3' - 10 1/2" 3 1/2" 10"29' - 1"3' - 8"3' - 8"5 1/2" 12 2 10 7 131 131 OP T . 2x6 WALL 1 A1.500 10 9 5' - 7 1/2"8' - 9 1/2"1' - 1 1/2"5' - 0" 1' - 5 " 5' - 8 " 9" 124 129 127 128 133 123 2030 FX 145 2- S T R Y CL G 9' - 0 " CL G 9'-0" CLG 2-STRY CLG 131 131 6' - 0 " 2 A1.500 23' - 0" 109 107 10 7 21080 3068 SC 152 150 11 1/2" 9 1/4" 9 1 / 4 " 2' - 11" 2' - 1 " 8' - 5 1 / 4 " 15' - 2 1/2" 6' - 10 1/2" 2' - 0 " 7' - 1 " 5' - 1" 2' - 1" 4' - 8 1/2" 7' - 1 " 10' - 1" 5' - 0"2' - 4 1/2" 2' - 5 1/2"5' - 10 1/2" OP T . OP T . CARPET VINYL TILE HARDWOOD LVP CARPET VINYL TILE HARDWOOD LVP CARPET VINYL TILE HARDWOOD LVP IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.110 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t MAIN FLOOR PLAN - ELEVATION B CRAFTSMAN SCALE: 1/4" = 1'-0" Main Floor Plan -Elevation A AREA SCHEDULE - STANDARD - ELEV A AREA NAME AREA ELEVATION A MAIN FLOOR LIVABLE 1299 SF UPPER FLOOR LIVABLE 1361 SF LIVABLE 2660 SF 2-CAR GARAGE 431 SF PORCH 97 SF DECK 111 SF UNFINISHED BASEMENT 1173 SF NON-LIVABLE 1812 SF ELEVATION A 4472 SF GENERAL FLOOR PLAN NOTES • MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) • WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. • PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. • ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. • PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. • SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. • PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. • ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) • ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) • CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. • ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. • ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. • FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. FLOOR PLAN KEYNOTES 101 SINK W/ GARBAGE DISPOSAL. 102 DISHWASHER. 103 REFRIGERATOR. 104 RANGE W/ HOOD. 107 PANTRY SHELVES PER BUILDER SPEC. 108 BASE CABINETS. 109 UPPER CABINETS. 110 WATER CLOSET. 112 PED. SINK. 122 ROD & SHELF. 123 ATTIC ACCESS. 124 HANDRAIL. 126 LINE OF OVERHEAD GARAGE DOOR IN OPEN POSITION. 127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD IN GARAGE AS REQUIRED BY CODE. 128 SLOPE GARAGE FLOOR 1/8" PER FOOT TOWARD GARAGE DOOR OPENING. 129 LINE OF FOUNDATION BELOW. 130 LINE OF SOFFIT ABOVE (REFER TO EXTERIOR ELEVATIONS FOR HEIGHTS AND DETAILS). 131 GYPSUM BOARD OPENING 8'-0" AT MAIN FLOOR & 7'-0" AT UPPER FLOOR. 133 LINE OF FRAMING ABOVE. 138 EXTERIOR GUARDRAIL W/ BALLUSTERS TO BE SPACED SUCH THAT 4" SPHERE CANNOT PASS BETWEEN BALUSTERS. 139 MASONRY WAINSCOT. 145 SHELF AT FINISH FLOOR LEVEL. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 152 TOWEL RING 48" A.F.F. 2x10 WALL DN 1 6 R I S E R S A-2 A1.400 A-1 A1.400 58' - 0" 5' - 0"11' - 0"16' - 0"5' - 5 1/2"20' - 6 1/2" 2' - 9"2' - 3"5' - 6"5' - 6"2' - 6"2' - 6"5' - 5"5' - 7"2' - 5"3' - 0 1/2" 10' - 0 1/2"10' - 6" 5' - 0 " 1' - 0 " 35 ' - 0 " 2040 FX TEMP3050 DH2040 FX 3050 DH 2040 FX TEMP 3 -2020 FX 35 ' - 0 " 15 ' - 4 " 2' - 0 " 11 ' - 7 1 / 2 " 4' - 0 1 / 2 " 11 ' - 4 " 6' - 0 " 8' - 6 1 / 2 " 4' - 0 " 12 ' - 6 1 / 2 " OPEN TO BELOW BEDROOM 4 BATH 2 LAUNDRY W.I.C.OWNER'S BATH OWNER'S SUITE W.I.C. W.I.C. BEDROOM 3 BEDROOM 2 W.I.C. 7' - 8 1 / 2 " 7' - 2 1 / 2 " 2' - 5 1 / 2 " D W 2' - 5 1/2"7' - 9"11' - 10 1/2"4' - 2" 2' - 6 " 10 ' - 8 " 2' - 6 " 15 ' - 8 " 2' - 0 " 58' - 0" 20 3 0 F X 2 -3050 DH 2030 DH2030 FX 5068 BP 26 6 8 2468 2668 24 6 8 30 5 0 D H TE M P . 2668 2868 2468 24 6 8 3 -3050 DH 20 4 0 D H 20 4 0 D H 2468 24 6 8 2468 26 6 8 20 3 0 F X 2468 27 ' - 0 " 11' - 4 1/2"3' - 3"12' - 3 1/2"11' - 11"14' - 1"5 1/2" 5' - 3 1 / 2 " 5' - 1 0 1 / 2 " 3' - 7 " 3' - 1 1 1 / 2 " 5' - 6 1 / 2 " 3 1 / 2 " 5' - 2 1 / 2 " 3' - 1 0 1 / 2 " 3 1 / 2 " 3' - 1 " 3 1 / 2 " 36x48 113111 110 116 11 1 11 1 11 0 122 12 2 122 119 118 12 1 117 12 2 122 122 122 12 2 2x 6 W A L L 132 1 A1.500 134 123 010 134 1' - 7" 122 12 2 2x 6 W A L L 2 A1.500 7' - 3 1/2"7' - 6 1/2" 4068 BP 117 152 150 151 150 152 152 OP T . OPT. OP T . OP T . 14' - 1" 14 ' - 9 " 9' - 5 1/2" 5' - 0"4' - 0" 2' - 1 " 5' - 10 1/2"3' - 4 1 / 2 " 7' - 6 " 4' - 2"2' - 8 1/2" 6' - 10 1/2" 10' - 3"5' - 0 " 11' - 1" 7' - 2 1/2" 3' - 6" 6' - 6 1/2" 4' - 8 1/2"10' - 1" 7' - 0 1 / 2 " 5' - 1 1 1 / 2 " 3' - 10 1/2"2' - 1 " 10 ' - 1 " 5' - 2"10' - 3"5' - 0"5 1/2" 20' - 6 1/2" 7' - 5 1 / 2 " CARPET VINYL TILE HARDWOOD LVP IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.120 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t UPPER FLOOR PLAN - ELEVATION B CRAFTSMAN AREA SCHEDULE - STANDARD - ELEV A AREA NAME AREA ELEVATION A MAIN FLOOR LIVABLE 1299 SF UPPER FLOOR LIVABLE 1361 SF LIVABLE 2660 SF 2-CAR GARAGE 431 SF PORCH 97 SF DECK 111 SF UNFINISHED BASEMENT 1173 SF NON-LIVABLE 1812 SF ELEVATION A 4472 SF SCALE: 1/4" = 1'-0" Upper Floor Plan -Elevation A GENERAL FLOOR PLAN NOTES • MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) • WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. • PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. • ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. • PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. • SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. • PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. • ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) • ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) • CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. • ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. • ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. • FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. FLOOR PLAN KEYNOTES 010 HANDRAIL. 110 WATER CLOSET. 111 LAV. SINK. 113 SHOWER (36X48). 116 TUB/SHOWER (33X60). 117 LINEN SHELVES PER BUILDER SPEC. 118 WASHER. 119 DRYER. 121 LINE OF SHELF ABOVE. 122 ROD & SHELF. 123 ATTIC ACCESS. 132 HALF WALL @ 36" A.F.F. W/ WOOD CAP. 134 LINE OF FRAMING BELOW. 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. MAIN FLOOR MAIN PLATE 9' - 1 1 / 8 " UPPER FLOOR UPPER PLATE 8' - 1 1 / 8 " TOP OF FOUNDATION 5 12 5 12 5 12 5 12 5 12 2' - 0 " 202 203 213 221 206 215 222 222 222 AD.3 13 AD.2 2 AD.2 4 AD.2 7 AD.1 10 AD.2 11 AD.2 8 AD.1 1 AD.2 211 207 212 223 221 8' - 0 " 216 OPT OPT 214 MAIN FLOOR MAIN PLATE 9' - 1 1 / 8 " UPPER FLOOR UPPER PLATE 8' - 1 1 / 8 " TOP OF FOUNDATION BASEMENT FLOOR 8' - 8 " 7 AD.1 11 AD.2 222 3 AD.1 211 213 202 223 212 222 7 AD.2 214 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.200 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t EXTERIOR ELEVATIONS - ELEVATION B CRAFTSMAN SCALE: 1/4" = 1'-0" Front Elevation SCALE: 1/4" = 1'-0" Rear Elevation Elevation B -Craftsman EXTERIOR ELEV KEYNOTES 202 6" LAP SIDING. 203 SHAKE SIDING. 204 VERTICAL SIDING. 206 STONE VENEER. 207 STONE CAP. 211 1x8 FASCIA/RAKE. 212 5/4x6 FRIEZE TRIM. 213 5/4x6 CORNER TRIM. 214 5/4x4 TRIM. 215 5/4x6 TRIM. 216 5/4x8 TRIM. 220 DECORATIVE LOUVER (SIZE AS NOTED). 221 DECORATIVE BRACKET. 222 COMPOSITION SHINGLES. 223 RAILING PER BUILDERS SPEC. EXTERIOR ELEVATION NOTES • REFER TO GENERAL NOTES AND DETAIL SHEETS FOR TYPICAL REQUIREMENTS AND MATERIALS SPECIFIC TO THIS PROJECT. • GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN. BUILDER SHALL VERIFY AND COORDINATE PER ACTUAL SITE CONDITIONS. • BUILDER TO PROVIDE ROOF AND SOFFIT VENTS SPECIFIED BY ATTIC VENT SCHEDULE, OR APPROVED EQUAL. • PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER. • INSTALL ALL PRE-MANUFACTURED MATERIALS PER MANUFACTURER'S REQUIREMENTS, RECOMMENDATIONS, AND SPECIFICATIONS. INSTALLATION REQUIREMENTS TO BE PROVIDED BY BUILDER. ALL ITEMS SHOWN ARE STANDARD U.N.O. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. MAIN FLOOR MAIN PLATE 9' - 1 1 / 8 " UPPER FLOOR UPPER PLATE 8' - 1 1 / 8 " TOP OF FOUNDATION BASEMENT FLOOR 8' - 8 " 6 12 4 12 6 12 4 12 202 213 211 206 207 1 AD.2 2 AD.2 10 AD.2 11 AD.2 7 AD.1 2' - 0 " 221 212 214 223 215 MAIN FLOOR MAIN PLATE 9' - 1 1 / 8 " UPPER FLOOR UPPER PLATE 8' - 1 1 / 8 " TOP OF FOUNDATION BASEMENT FLOOR 6 12 6 12 6 12 4 12 202 212 211 213 10 AD.2 11 AD.2 7 AD.1 4 AD.2 222 222 221 214 223 215 8' - 8 " 23 . 6 ' PCG IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.201 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t EXTERIOR ELEVATIONS - ELEVATION B CRAFTSMAN SCALE: 1/4" = 1'-0" Left Elevation SCALE: 1/4" = 1'-0" Right Elevation Elevation B -Craftsman EXTERIOR ELEV KEYNOTES 202 6" LAP SIDING. 203 SHAKE SIDING. 204 VERTICAL SIDING. 206 STONE VENEER. 207 STONE CAP. 211 1x8 FASCIA/RAKE. 212 5/4x6 FRIEZE TRIM. 213 5/4x6 CORNER TRIM. 214 5/4x4 TRIM. 215 5/4x6 TRIM. 216 5/4x8 TRIM. 220 DECORATIVE LOUVER (SIZE AS NOTED). 221 DECORATIVE BRACKET. 222 COMPOSITION SHINGLES. 223 RAILING PER BUILDERS SPEC. EXTERIOR ELEVATION NOTES •REFER TO GENERAL NOTES AND DETAIL SHEETS FOR TYPICAL REQUIREMENTS AND MATERIALS SPECIFIC TO THIS PROJECT. •GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN. BUILDER SHALL VERIFY AND COORDINATE PER ACTUAL SITE CONDITIONS. •BUILDER TO PROVIDE ROOF AND SOFFIT VENTS SPECIFIED BY ATTIC VENT SCHEDULE, OR APPROVED EQUAL. •PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER. •INSTALL ALL PRE-MANUFACTURED MATERIALS PER MANUFACTURER'S REQUIREMENTS, RECOMMENDATIONS, AND SPECIFICATIONS. INSTALLATION REQUIREMENTS TO BE PROVIDED BY BUILDER. ALL ITEMS SHOWN ARE STANDARD U.N.O. CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. OPT OPT A-2 A1.400 A-1 A1.400 6: 1 2 4: 1 2 6: 1 2 5:12 5:12 5:12 4: 1 2 5:12 5:12 4: 1 2 6: 1 2 TYP. 1' - 0" EAVE TYP. 1' - 0" RAKE 1403 SF ZONE 1 317 SF ZONE 2 81 SF ZONE 3 30 SF ZONE 4 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.300 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t ROOF PLAN - ELEVATION B CRAFTSMAN SCALE: 1/4" = 1'-0" Roof Plan -Elevation B Craftsman CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. NOTE: * REQUIRED NET FREE AREAS ARE CALCULATED BY MULTIPLYING THE ACTUAL ATTIC AREA (SQ FT) BY 1/300. 40%-50% OF TOTAL NET FREE VENTED AREA IS REQUIRED AT THE RIDGE (HIGH) WITH REMAINING REQUIRED IN THE SOFFIT (LOW). WHEN NO "HIGH / LOW" VENTING IS PROVIDED, THE REQUIRED NET FREE AREA IS 1/150 OF THE ACTUAL AREA. ATTIC VENTILATION SCHEDULE - ELEVATION A ZONE ATTIC AREA VENT RATIO REQUIRED UPPER VENTILATION REQUIRED LOWER VENTILATION ZONE 1 1403 SF 1 / 300 337 in² 337 in² ZONE 2 317 SF 1 / 300 76 in² 76 in² ZONE 3 81 SF 1 / 150 78 in² 0 in² ZONE 4 30 SF 1 / 150 29 in² 0 in² MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE 8' - 1 1/8" TOP OF FOUNDATION BASEMENT FLOOR (TYP) 1' - 4" HEEL 2-CAR GARAGE STORAGE OWNER'S SUITE 6 12 6 12 15' - 4" ROOF TRUSSES @ 24" O.C. 15' - 8" 31' - 0" C1 A1 D1 9' - 1 1/8" 8' - 8" MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE 8' - 1 1/8" TOP OF FOUNDATION BASEMENT FLOOR (TYP) 4" HEEL UNFINISHED BASEMENTMECHANICAL POWDER KITCHEN DINING BATH 2LAUNDRYBEDROOM 3 ROOF TRUSSES @ 24" O.C. 5' - 0"10 1/2" ROOF TRUSSES @ 24" O.C. 27' - 1 1/2" ROOF TRUSSES @ 24" O.C. 2' - 0" 35' - 0" (TYP) 1' - 4" HEEL6 12 6 12 4 12 4 12 C1 A1 B1 C1 D1 PORCH DECK GIRDER TRUSS 9' - 1 1/8" 8' - 8" IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.400 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t BUILDING SECTIONS - ELEVATION B CRAFTSMAN Building Sections Elevation B -Craftsman SCALE: 1/4" = 1'-0" Section B-1 SCALE: 1/4" = 1'-0" Section B-2 CONSTRUCTION ASSEMBLIES A1.COMPOSITION ROOF CONSTRUCTION: COMPOSITION ROOF SHINGLES o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE. A2.METAL ROOF CONSTRUCTION: METAL PANEL o/ UNDERLAYMENT o/ ROOF SHEATHING o/ ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD WITH INSULATION ABOVE B1. TYPICAL SIDING WALL CONSTRUCTION: SIDING o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. B2. TYPICAL STONE VENEER WALL CONSTRUCTION: ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) o/ WATER RESISTANT BARRIER o/ EXTERIOR WALL SHEATHING o/ 2x4 OR 2x6 STUDS, 16" o/c, w/ INSULATION IN CAVITIES. INTERIOR: 1/2" GYPSUM BOARD o/ MOISTURE VAPOR RETARDER. C1.TYPICAL FLOOR CONSTRUCTION: FINISHED FLOOR o/ 3/4" FLOOR SHEATHING o/ FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS. MAIN FLOOR CEILINGS: 5/8" GYPSUM BOARD. D1.CONCRETE SLAB CONSTRUCTION: CONCRETE SLAB o/ 6 MIL. POLYETHYLENE VAPOR BARRIER o/ 4" MINIMUM GRANULAR FILL. MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR 8' - 8" 3' - 7 1/2"13 TREADS @ 10" = 10' - 10" 4' - 0"10' - 10" 14 EQ RISERS 2 R. 14 EQ RISERS 1 R. 15 EQUAL RISERS 9' - 7 1/2" 16 EQUAL RISERS 9' - 11 1/8" 3' - 2" MAX 2' - 10" MIN MIN. CLEARANCE 6' - 8" LANDING LANDING 2 A1.500 MIN. CLEARANCE 6' - 8" 3'-2" MAX 2'-10" MIN. 9' - 1 1/8" 8' - 1 1/8" MAIN FLOOR MAIN PLATE UPPER FLOOR UPPER PLATE TOP OF FOUNDATION BASEMENT FLOOR 1 A1.500 8' - 8" 15 EQUAL RISERS 9' - 7 1/2" 16 EQUAL RISERS 9' - 11 1/8" LANDING 1 R. 14 EQ RISERS 2 R. 14 EQ RISERS LANDING 8' - 1 1/8" 9' - 1 1/8" IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.500 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t STAIR SECTION 1 Stair Section SCALE: 1/4" = 1'-0"2 Stair Section SCALE: 1/4" = 1'-0" UP UNEXCAVATED MECHANICAL UNEXCAVATED AI R H A N D L E R HRV 14' - 6"3 1/2"4' - 1"3 1/2"17' - 0"0" 5' - 0" 10' - 7" 14' - 9" 10" 3050 DH (2) 3068 FR DR (TEMP) 2' - 0" 3' - 0" 10' - 8 1/2" 3' - 3" 10 1/2" 3 1/2" 10' - 0 1/2" 110 116 111 107 017 21068 21068 24 6 8 1668 BONUS ROOM BATH 3 STORAGE 13' - 1"6' - 7"3 1/2"15' - 9"10" 1 A1.500 004 2 A1.500 STORAGE STORM SUMP 21068 WH 21 0 6 8 151 152 150 OPT. 21068 12' - 6"8' - 6"3' - 6" 2' - 0" 13' - 1" 19' - 8" 3' - 6" 4' - 6" 4' - 8" 1' - 6 1/2" 5' - 0" 8' - 6 1/2" 23' - 0"14' - 0"21' - 0" 8' - 0" CARPET VINYL TILE HARDWOOD LVP IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . A1.600 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t FLOOR PLAN OPTIONS - ALL ELEVATIONS GENERAL FLOOR PLAN NOTES • MAIN FLOOR WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 8'-0 7/8". UPPER FLOOR AND BASEMENT LEVEL WINDOWS WILL HAVE A WINDOW HEAD HEIGHT OF 7'-0 7/8". (U.N.O.) • WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS TO HAVE A CLEAR EGRESS OPENING -SEE GENERAL NOTES. WINDOWS LOCATED AT +72" ABOVE FINISHED GRADE MUST COMPLY WITH IRC R312.2. • PROVIDE GYPSUM BOARD -SEE GENERAL NOTES FOR CODE REQUIREMENTS. • ANY EXTERIOR SHELF BELOW WINDOW SILL SHALL SLOPE AWAY 1/4" PER FOOT. APPLY ELASTOMERIC SEALANT. • PROVIDE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE CONTROL VALVES FOR ALL SHOWER AND TUB / SHOWER COMBINATIONS. • SHOWER AREA WALLS SHALL BE FINISHED WITH APPROVED 'CEMENT', 'FIBER-CEMENT', OR 'GLASS MAT GYPSUM' BACKERS AND NON- ABSORBANT SURFACE TO A HEIGHT OF 72" ABOVE THE DRAIN -SEE GENERAL NOTES, SECTION IX, AND IRC SECTION R702.4.2. • PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS. • ALL PARTITIONS ARE DIMENSIONED TO FACE OF FRAMING. (U.N.O.) ALL UNDIMENSIONED PARTITIONS ARE 3 1/2" ROUGH (U.N.O.) • ALL ANGLED PARTITIONS ARE 45 DEGREES. (U.N.O.) • CENTER-LINE OF WATER CLOSET SHALL BE A MINUMUM OF 15" FROM ANY VERTICAL SURFACE OR FIXTURE. • ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS. • ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS U.N.O. TRUSS MFG. TO SIZE MEMBERS, FESTENERS, HANGERS & SET SPACING FOR ALL TRUSSES. • FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS. NOTE: SEE STANDARD FLOOR PLANS, ELECTRICAL PLANS, ROOF PLANS, AND ELEVATIONS, FOR INFORMATION NOT SHOWN, IN AREAS ADJACENT TO OPTIONS, THAT DOES NOT CHANGE. Floor Plan Options SCALE: 1/4" = 1'-0" Opt. Finished Basement Basement Plan All Elevations Similar FLOOR PLAN KEYNOTES 004 PROVIDE 5/8" TYPE "X" GYPSUM BOARD ON WALLS AND CEILINGS UNDER ACCESSIBLE ENCLOSED STAIRS. 017 GYPSUM BOARD OPENING 7'-6" AT BASEMENT. 107 PANTRY SHELVES PER BUILDER SPEC. 110 WATER CLOSET. 111 LAV. SINK. 116 TUB/SHOWER (33X60). 150 TOILET PAPER HOLDER 19" MIN A.F.F. 151 TOWEL BAR 48" A.F.F. 152 TOWEL RING 48" A.F.F. IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . AD.4 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t CABINET PLANS SD CO EM SD CO EM 3 AIR HANDLER HRV WP/GFCI UP TO FIXTURE 3 3 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . E1.100 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t BASEMENT ELECTRICAL PLAN - ELEVATION B CRAFTSMAN GENERAL ELECTRICAL NOTES A. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G. FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H. KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J. ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K. CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L. SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M. ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N. ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O. PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P. PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q. OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R. LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S. UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T. NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U. CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V. ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER SCALE: 1/4" = 1'-0" Basement Electrical Plan -Elevation B Craftsman WP D CH SD CO TV WPWP WP WP WP D CH SD CO TV GFCI GFCI GF C I 22 0 V +8 4 " A F F 3 3 WP/GFCI 3 3 TO LIGHT BELOW GFCI GFCI TO LIGHT ABOVE 3 TO LIGHT ABOVE WP/GFCI WP / G F C I GFCI GFCI CHANDELIER 3 3 CHANDELIER SURFACE SURFACE SURFACE SURFACE CERAMIC CERAMIC CERAMICCERAMIC WAC LIGHT WAC LIGHT WAC LIGHT WAC LIGHT WAC LIGHT WAC LIGHT WAC LIGHT SURFACE CERAMIC GF C I GFCI IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S . E1.110 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t MAIN FLOOR ELECTRICAL PLAN - ELEVATION B CRAFTSMAN SCALE: 1/4" = 1'-0" Main Floor Electrical Plan -Elevation B Craftsman GENERAL ELECTRICAL NOTES A. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G. FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H. KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J. ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K. CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L. SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M. ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N. ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O. PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P. PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q. OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R. LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S. UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T. NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U. CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V. ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER WP TV SD SD SD SD SD CO 30 A SD CO WP TV SD SD SD SD SD CO 30 A SD CO TO SWITCH BELOW 3 4 3 3 GFCI GFCI GFCI 220V GFCI CHANDELIER SURFACE WAC LIGHT SURFACE WAC LIGHT WAC LIGHT WAC LIGHT WAC LIGHT SURFACE SURFACE SURFACE WAC LIGHT WAC LIGHT WAC LIGHT SURFACE IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 2/12/2024 4:53:10 PM C:\Users\charlotte\Downloads\SF-3_V2019.rvt E1.120 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t UPPER FLOOR ELECTRICAL PLAN - ELEVATION B CRAFTSMAN 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020SCALE: 1/4" = 1'-0" Upper Floor Electrical Plan -Elevation A GENERAL ELECTRICAL NOTES A. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G. FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H. KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J. ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K. CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L. SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M. ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N. ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O. PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P. PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q. OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R. LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S. UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T. NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U. CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V. ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER TV SD SD CO EM AIR HANDLER HRV 3 GFCI WP/GFCI TO SWITCH ABOVE 3 3 4 IS S U E D A T E : RE V I S I O N S JOB NO:PROJ MGR: CHECKED:DRAWN: TH E S E P L A N S A N D S P E C I F I C A T I O N S A R E P R O T E C T E D UN D E R F E D E R A L C O P Y R I G H T L A W S . © B S B D E S I G N MA I N T A I N S O W N E R S H I P O F S U C H A N D A L L R I G H T S AN D P R I V I L E G E S .BSBDESIGN.COM 2/12/2024 4:53:10 PM C:\Users\charlotte\Downloads\SF-3_V2019.rvt E.1600 PLAN SF-3 SF210303.00 MB ST JM 0-13 -20 2 3 Hi l l s i d e a t O ' B r i e n F a r m Vi l l a g e G r e e n H i l l t o p S i n g l e F a m i l y So u t h B u r l i n g t o n , V e r m o n t OPT FINISHED BASEMENT ELECTRICAL 4601 Westown Parkway, Suite 208 West Des Moines, Iowa 50266 515 273 3020 GENERAL ELECTRICAL NOTES A. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. B. PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)AS REQUIRED BY 2015 IRC E3902 AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. C. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS / CUTOFFS. D. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. E. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. F. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE-PHASE, 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT PER IRC SECTION E3902.16. G. FIXTURES LOCATED IN CLOTHES CLOSETS SHALL BE COVERED AND COMPLY w/ 2015 IRC E4003.12 REGARDING DISTANCES AND TYPE OF FIXTURE. H. KITCHEN OVEN / RANGE AND ELECTRIC DRYER SHALL BE SUPPLIED BY 4-WIRE RECEPTACLE. I. ALL RECEPTACLE AND FIXTURE BOXES IN THE GARAGE SHALL BE OF METAL OR MATERIAL TESTED FOR FIRE RESISTIVE ASSEMBLIES AND INSTALLED IN ACCORDANCE WITH THE TESTED ASSEMBLY PER 2015 IRC E3902. J. ALL PRE-WIRED, CEILING-MOUNTED OUTLET BOXES SHALL BE LISTED IN ACCORDANCE WITH 2015 IRC E3905.8 TO SUPPORT A CEILING FAN, WHERE ACCEPTABLE. CEILING FANS NOT EXCEEDING 70 POUNDS (WITH OR WITHOUT ACCESSORIES) MAY BE SUPPORTED BY OUTLET BOXES PROVIDED THE BOXES ARE IDENTIFIED FOR SUCH USE PER 2015 IRC SECTION E3905.8. K. CEILING FANS OR LIGHTS INSTALLED OUTDOORS OR UNDER PATIO COVERS MUST BE LISTED FOR DAMP LOCATIONS PER 2015 IRC SECTION E4003.9. L. SPAS AND HYDRO-MASSAGE TUBS SHALL COMPLY WITH 2015 IRC SECTION E4209. M. ELECTRICAL PLAN DESIGNATES SCHEMATIC LAYOUT ONLY. ALL ELECTRICAL ELEMENTS TO BE VERIFIED BY BUILDER PRIOR TO START OF CONSTRUCTION. N. ARTIFICIAL LIGHTING MUST BE CAPABLE OF ILLUMINATION NO LESS THAN 1 FOOT-CANDLE, MEASURED AT CENTER OF TREADS AND LANDINGS. O. PROVIDE TAMPER RESISTANT RECEPTACLES PER IRC SECTION E4002.14. RECEPTACLES IN THE FOLLOWING LOCATIONS SHALL NOT BE REQUIRED TO BE TAMPER RESISTANT: 1) RECEPTACLES LOCATED MORE THAN 5'-6" ABOVE THE FLOOR. 2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. 3) A SINGLE RECEPTACLE FOR A SINGLE APPLIANCE OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, WHERE SUCH RECEPTACLES ARE LOCATED IN SPACES DEDICATED FOR THE APPLIANCES SERVED, AND, UNDER CONDITIONS OF NORMAL USE, THE APPLIANCES ARE NOT EASILY MOVED FROM ONE PLACE TO ANOTHER. P. PROVIDE DISCONNECT AT ALL HVAC EQUIPMENT WITH CLEAR ACCESS 30" WIDE BY 36" IN FRONT, WITHIN LINE OF SIGHT OF EQUIPMENT. Q. OUTLET BOXES IN WALLS USED AS LUMINAIRE OR LAMPHOLDER OR CEILING OUTLET BOXES USED EXCLUSIVELY FOR LIGHTING, THE BOX SHALL BE DESIGNED OR INSTALLED SO THAT A LUMINAIRE OR LAMPHOLDER CAN BE ATTACHED. SUCH BOXES SHALL BE CAPABLE OF SUPPORTING A LUMINAIRE WEIGHING UP TO 50 POUNDS, EXCEPT WALL OUTLETS WHEN PROPERLY LABELED. R. LIGHT FIXTURES IN CEILING ENVELOPE EITHER TYPE IC AIRTIGHT, TYPE IC MAX 2 CFM LEAKAGE, OR NON-IC IN AIRTIGHT BOX. NON-IC REQUIRES CLEARANCE TO COMBUSTIBLES. IRC N1102.4.5 & E4004.8. S. UNDERGROUND FEEDER CABLE TYPE UF REQUIRED FOR ANY UNDERGROUND INSTALLATIONS PER IRC SECTION E3801. T. NM WIRE SIZING PER IRC SECTIONS E3705.1 & E3705.4.4: 30 AMPS:#10 CU or #8 AL 40 AMPS:#8 CU or #6 AL 45 AMPS:#6 CU or #4 AL 50 AMPS:#6 CU or #4 AL 60 AMPS:#4 CU or #3 AL 100 AMPS:#1 CU or 1/0 AL U. CIRCULATING HOT WATER SYSTEMS SHALL BE PROVIDED w/ AUTOMATIC OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT-WATER CIRCULATING PUMP WHEN SYSTEM IS NOT IN USE. V. ALL 15A & 20A, 125V & 250V RECEPTACLES, INSTALLED OUTDOORS IN DAMP AND WET LOCATIONS, SHALL BE LISTED WEATHER-RESISTANT TYPE, WEATHER-PROOF COVER, AND TAMPER-RESISTANT PER 2015 IRC E4002.8, E4002.9, E4002.10, & E4002.14. ELECTRICAL DEVICE SWITCHES OVER COUNTER.......................................... WALL OUTLETS OVER COUNTER................................. REMAINING SWITCHES.................................................. WALL OUTLETS............................................................... BATH VANITY BRACKET OUTLET (1" ABOVE TOP OF MIRROR)............................. WATER SOFTENER & SUMP OUTLETS......................... TELEPHONE OUTLETS.................................................... TELEVISION OUTLETS.................................................... EXTERIOR GFCI OUTLETS.............................................. GARAGE GFCI (ABOVE GARAGE FLOOR)..................... BASEMENT WALL OUTLETS.......................................... FRONT DOOR COACH LIGHT.......................................... GARAGE DOOR COACH LIGHT (ABOVE GARAGE FLOOR)..................................... DINING AND NOOK FIXTURE...................................... FOYER AND STAIRWAY FIXTURE.............................. THERMOSTAT.................................................................. DOORBELL CHIMES......................................................... DOORBELL BUTTON.................................................... KITCHEN HOOD FAN 'WHIP'............................................ KITCHEN WALL HUNG MICROWAVE OUTLET................................................................... KITCHEN DISHWASHER RECEPTACLE..................... KITCHEN RANGE............................................................. KITCHEN REFRIGERATOR.............................................. ISLAND / PENINSULA........................................ WASHER / DRYER OUTLET............................................. CL =CENTER LINE 1 =FIELD VERIFY 2 =MASTER BATH STANDARD 36" HIGH VANITY TO BE RAISED 4" ABOVE FINISHED FLOOR 48" TO CL 48" TO CL 48" TO CL 12" TO CL 80" TO CL1,2 48" TO CL 12" TO CL 12" TO CL 12" TO CL 48" TO CL 48" TO CL 72" TO CL 84" TO CL 64" TO BTM OF FIXTURE 96" TO BTM OF FIXTURE 54" TO CL 84" TO CL LEVEL w/ DR HANDLE 66" TO CL 76" TO CL UNDER SINK 24" TO CL 48" TO CL LESS THAN 12" BELOW COUNTER 48" TO CL TR SW WP TV CH S T RJB J SD CO HD CO SD WP VP FL WP D EM ELECTRIC METER ELECTRIC PANEL ELECTRICAL SYMBOL LEGEND SINGLE POLE OUTLET DUPLEX CONVENIENCE OUTLET FOUR-PLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER WEATHERPROOF DUPLEX OUTLET GROUND-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ARC-FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET HALF-SWITCHED DUPLEX OUTLET DUPLEX OUTLET IN FLOOR OVERHEAD DUPLEX OUTLET 220 VOLT OUTLET SPECIAL PURPOSE OUTLET / JUNCTION BOX DUPLEX OUTLET w/ USB WALL SWITCH THREE-WAY WALL SWITCH FOUR-WAY WALL SWITCH RHEOSTAT SWITCH DIMMER SWITCH THREE-WAY DIMMER SWITCH PUSH BUTTON KEYPAD WALL MOUNTED LED LIGHT FIXTURE WALL MOUNTED WEATHERPROOF LED LIGHT FIXTURE CEILING MOUNTED LED LIGHT FIXTURE CEILING MOUNTED PENDANT LIGHT FIXTURE CEILING MOUNTED LED DISC LIGHT FIXTURE CEILING MOUNTED MINI-PENDANT LIGHT FIXTURE RECESSED LED LIGHT FIXTURE RECESSED VAPOR PROOF LIGHT FIXTURE (SUITABLE FOR WET or DAMP LOCATIONS) RECESSED WEATHERPROOF LED LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE MINI RECESSED LED LIGHT FIXTURE 110V SMOKE DETECTOR w/ BATTERY BACKUP & INTERCONNECTED CARBON MONOXIDE DETECTOR HEAT DETECTOR 110V SMOKE / CO DETECTOR w/ BATTERY BACKUP & INTERCONNECTED EXHAUST FAN (VENT TO EXTERIOR) EXHAUST FAN / LIGHT COMBINATION (VENT TO EXTERIOR) EXHAUST FAN w/ HEAT LAMP (VENT TO EXTERIOR) JUNCTION BOX REINFORCED JUNCTION BOX THERMOSTAT SPEAKER DOOR CHIMES TELEVISION DATA DISCONNECT WP/GFCI GFCI AFCI 220V USB 3 3D PB KEYPAD 4 R D PEND DISC MINI PEND MINI COMBO CEILING MOUNTED WEATHERPROOF LED LIGHT FIXTURE STRUCTURED WIRING PANEL LOW VOLTAGE TRANSFORMER NOTE: SEE STANDARD FLOOR PLANS, ELECTRICAL PLANS, ROOF PLANS, AND ELEVATIONS, FOR INFORMATION NOT SHOWN, IN AREAS ADJACENT TO OPTIONS, THAT DOES NOT CHANGE. SCALE: 1/4" = 1'-0" Opt. Finished Basement Basement Electrical Plan New SMh Rim 408.95 Inv. in 402.73 Inv. out 402.63 New SMh Rim 414.82 Inv. in 409.02 Inv. out 408.92 New SMh Rim 417.53 Inv. in 411.73 Inv. out 411.63 New SMh Rim 415.9 Inv. in 410.23 Inv. out 410.13 New CB Rim 411.35 Inv. in 397.75 Inv. out 397.65 Inv. fd 399.0 New CB Rim 411.35 Inv. fd. 399.1 Inv. out 397.85 New CB Rim 414.95 Inv. in 402.75 Inv. out 402.65 Inv. fd 403.9 New CB Rim 414.95 Inv. fd 404.1 Inv. out 402.85 New CB Rim 417.30 Inv. in 406.45 Inv. out 406.35 Inv. fd 407.7 New CB Rim 417.30 Inv. fd 407.8 Inv. out 406.55 Lot 16 2.81 ac Lot 20 2.13 ac 16-4 16-7 16-6 16-5 16-8 16-9 16-10 16-11 16-12 32-1 32-2 32-3 32-4 32-5 32-6 20-7 20-8 20-9 20-10 20-11 20-12 20-13 20-14 20-15 20-16 20-17 20-18 20-19 20-20 20-21 20-22 Lot 32 4.80 ac New 4" PVC SDR 35 sanitary service. s=14"/ft. min. Typical all units. G1 G2 G3 G4 G5 G6 New 8" PVC Sewer s=0.022 New 8" PVC S e w e r s = 0 . 0 1 2 New 8" PVC Sew e r s = 0 . 0 1 2 8' paved mul t i - u s e p a t h 11 Parking spaces Ne w 1 5 " H D P E Ne w 1 5 " HD P E Ne w 1 5 " HD P E New 18" HDPE s=0.19 New 15" HDPE s=0.025 New 15" HDP E s = 0 . 1 8 New 12" HDPE New 12" HDP E New Hydrant assembly New Hydrant assembly New 12" CL 52 D.I. water main New Hydrant assembly New 12" D.I. CL 5 2 w a t e r m a i n New 34" k copper water service and curb stop. Typical all units. New 12" gate valves New 12"tee with valve & thrust block New 45° bends with thrust blocks New SMh Rim 413.4 Inv. in 407.73 Inv. out 407.63 New 20' access and utility easement New 12" D.I . C L 5 2 w a t e r m a i n New underground power to existing 200 Old Farm Road. New 5' concrete sidewalk New 5' concrete sidewalk Ne w 4 ' c o n c r e t e s i d e w a l k PCG 418.5 PCG 418.0 PCG 417.0 PCG 416.0 PCG 414.75 PCG 413.5 PCG 412.25 PCG 410.75 PCG 408.75 PCG 412.2 PCG 414.2 PCG 416.2 PCG 418.4 PCG 417.2 PCG 417.0 PCG 417.5 PCG 417.5 PCG 417.25 PCG 416.2 PCG 415.6 HILLSIDE @ O'BRIEN FARM OWNER AND APPLICANT: ISSUED FOR PERMIT REVIEW NOT FOR CONSTRUCTION PROPERTY INFORMATION: C-3 SITE PLAN - LEO LANE and Old Farm Road Old Farm Road and Kennedy Drive, South Burlington, Vermont O'BRIEN BROTHERS 1855 WILLISTON ROAD SOUTH BURLINGTON, VT 05403 164 Main Street, Suite 201 P: (802) 878-0375 Colchester, Vermont 05446 email@krebsandlansing.com EASTVIEW SEE SHEET C-9 SE E S H E E T C - 2 SEE SHEET C-13 SE E S H E E T C - 4