HomeMy WebLinkAboutSP-24-03 - Supplemental - 0110 Kimball AvenueINSTALLATION TECHNICIAN:TELEPHONE: GENERAL NOTES & CONDITIONS (ALL TRADES) SHEET TITLE SHEET INDEX EQUIPMENT SPECIALIST (E.S.):TELEPHONE: JASON GOSSELIN (617) 719-3343 DR. MATTHEW GIULIANELLI SCV COVER SHEET SA.0 DENTAL EQUIPMENT FLOOR PLAN SA.1 DENTAL DIMENSION & REINFORCEMENT PLAN SP.1 SE.1 SED.1 SED.2 DENTAL PLUMBING SPECIFICATIONS DENTAL ELECTRICAL SPECIFICATIONS DENTAL EQUIPMENT DETAILS SCV 24 x 36N/A COVER SHEET PREPARED FOR: 1.DEFINITIONS HENRY SCHEIN, HENRY SCHEIN INC., HENRY SCHEIN DENTAL, OR HSD INC. REFERS TO THE EQUIPMENT SUPPLIER FOR THIS PROJECT ENGAGED BY THE OWNER UNDER A SEPARATE CONTRACT. E.S. - "EQUIPMENT & TECHNOLOGY SPECIALIST" IS A HENRY SCHEIN EMPLOYEE THAT SPECIALIZES IN THE MANAGEMENT OF EQUIPMENT AND/OR TECHNOLOGY SALES AND INSTALLATIONS AND HAS ASSISTED THE OWNER IN THE PREPARATION OF DRAWINGS AND SPECIFICATIONS FOR THE CONSTRUCTION OF THE PROPOSED FACILITIES. THE "GENERAL CONTRACTOR", ALSO KNOWN AS THE 'G.C.' IS REFERRED TO AS THE PERSON(S) OR ENTITY WHO HAS ENTERED INTO A CONTRACTUAL AGREEMENT WITH THE OWNER FOR THE WORK DEFINED IN SUCH AGREEMENT. THE G.C. IS RESPONSIBLE FOR ALL WORK CARRIED OUT BY THEIR SUBCONTRACTORS OR SUBTRADES. IF THE CONSTRUCTION OF THE PROJECT IS LET UNDER SEPARATE CONTRACTS BY THE OWNER, THE RESPONSIBILITIES STIPULATED BELOW SHALL APPLY TO EACH CONTRACTOR. THE "OWNER" IS REFERRED TO AS THE PERSON(S) OR ENTITY WHO OWNS OR LEASES THE PREMISES FOR WHICH A CONSTRUCTION AGREEMENT HAS BEEN ENTERED UPON WITH THE GENERAL CONTRACTOR. WHERE THE OWNER, AS REFERRED TO ABOVE, LEASES THE PREMISES THE ENTITY WHO HAS OWNERSHIP OF THE PROPERTY WILL BE REFERRED TO AS THE LANDLORD. THE "OWNER'S AGENT" IS A REPRESENTATIVE OF THE AGENT ACTING ON THEIR BEHALF AND MAY HAVE THE AUTHORITY TO MAKE DECISIONS IN THEIR ABSENCE. THIS MAY BE AN OFFICE MANAGER, AN ARCHITECT, AN ENGINEER, OR A PROJECT MANAGER HIRED BY THE OWNER. 2.DRAWINGS THESE DRAWINGS ARE PREPARED BY HENRY SCHEIN AS DENTAL CONSULTANTS FOR ASSISTING AN ARCHITECT/CONTRACTOR TO PRODUCE CONSTRUCTION DOCUMENTS & BUILD A DENTAL OFFICE. THEY DO NOT CONSTITUTE A COMPLETE SET OF CONSTRUCTION DOCUMENTS. ITEMS REQUIRED FOR BUILDING PERMITS OR CONSTRUCTION MAY NOT APPEAR ON THESE DRAWINGS. IF THESE DRAWINGS ARE BEING SUBMITTED FOR BUILDING PERMIT, IT REMAINS THE OWNER AND/OR GENERAL CONTRACTOR'S RESPONSIBILITY RETAIN THE PROPER CONSULTANTS TO PREPARE COMPLETE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. DOOR SPECIFICATIONS, LIGHTING DESIGN, FINAL REFLECTED CEILING PLANS, AND OTHER SPECIFICATIONS NOT COVERED IN THESE DRAWINGS ARE BY OTHERS. RETENTION OF OTHER CONSULTANTS SUCH AS AN ARCHITECT, M.E.P. ENGINEERS, OR SECURITY CONSULTANT, ARE THE RESPONSIBILITY OF THE OWNER AND/OR GENERAL CONTRACTOR. 3.HENRY SCHEIN, INC. RESPONSIBILITIES HENRY SCHEIN, INC. WILL ISSUE DETAILED DRAWINGS SHOWING CRITICAL LOCATIONS & REQUIREMENTS OF ALL DENTAL-SPECIFIC EQUIPMENT. THE E.S. WILL BE AVAILABLE FOR PERIODIC FIELD VISITS. VISITS WILL BE LIMITED TO A PRE-CONSTRUCTION ON-SITE MEETING, LAYOUT CHECKS AND INSTRUCTIONS TO THE VARIOUS TRADES IN THE CRITICAL ASPECTS OF THE WORK PERTAINING TO DENTAL AND ALLIED EQUIPMENT. ALL REQUESTS FOR FIELD VISITS SHALL ALLOW REASONABLE ADVANCED NOTICE. HENRY SCHEIN, INC. AND ITS REPRESENTATIVES WILL NOT ASSUME ANY RESPONSIBILITIES FOR DEVIATIONS FROM THESE DRAWINGS WITHOUT PRIOR WRITTEN CONSENT. PRIOR TO CONSTRUCTION, THE E.S. WILL VERIFY THE SITE DIMENSIONS OF THE SPACE PRIOR TO ENSURE THEY COINCIDE WITH THE DETAILED DRAWINGS. DURING CONSTRUCTION, THE E.S. WILL CHECK THE JOBSITE PERIODICALLY AS REQUIRED. THE E.S. WILL BE AVAILABLE TO ASSIST THE CONTRACTOR(S)AND THE OWNER IN THE INTERPRETATION OF THESE DRAWINGS AND SPECIFICATIONS. PRIOR TO ENCLOSING WALLS, THE GENERAL CONTRACTOR AND/OR THE FRAMING SUBCONTRACTOR IS REQUIRED TO COORDINATE WITH THE E.S. AND THE HENRY SCHEIN INSTALLATION TECHNICIAN. THIS INSPECTION IS CRITICAL TO ENSURE THAT THE WALL AND/OR CEILING SUPPORTS FOR DENTAL EQUIPMENT WILL MATCH WITH ANY CHANGES THAT MAY HAVE OCCURRED WITH THE OWNER'S EQUIPMENT ORDER. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO HAVE PLUMBING, ELECTRICAL, SUPPORT BACKING, AND LEAD INSTALLATION APPROVED BY MUNICIPAL INSPECTORS BEFORE POURING SLABS, ENCLOSING PARTITIONS AND CEILING. HENRY SCHEIN WILL NOT BE RESPONSIBLE FOR ANY UNFORESEEN CONDITIONS ARISING OUT OF, OR DURING THE COURSE OF, CONSTRUCTION NOR FOR ANY DEVIATIONS FROM DRAWINGS AND/OR SPECIFICATIONS WITHOUT PRIOR WRITTEN CONCENT. EQUIPMENT INSTALLATION A PRE-CONSTRUCTION MEETING IS REQUIRED WITH THE GENERAL CONTRACTOR, PLUMBER, ELECTRICIAN, CABINET MAKER, AND THE E.S. ALL TEMPLATES CRITICAL TO EQUIPMENT INSTALLATION WILL BE DISTRIBUTED AT THIS MEETING. THE E.S. WILL INSPECT PREMISES PRIOR TO THE INSTALLATION OF ITS EQUIPMENT AT WHICH TIME ALL FINISHES (CEILINGS, FLOORING, AND PAINTING) AND MECHANICAL WORK MUST BE COMPLETED. RESPONSIBILITIES FOR THE INSTALLATION AND/OR HOOKUP OF DENTAL EQUIPMENT WILL BE DEFINED IN THE SPECIFICATIONS FOR EACH TRADE. HENRY SCHEIN DENTAL REQUIRES THAT ALL APPLICABLE TRADES BE REPRESENTED AT THE TIME OF INSTALLATION. 4.GENERAL CONTRACTOR (G.C.)- RESPONSIBILITIES ALL ITEMS LISTED OR NOTED HEREIN ARE FOR GUIDANCE ONLY AND DO NOT NECESSARILY CONSTITUTE THE ENTIRE EXTENT OF THE WORK TO BE CARRIED OUT UNDER THE CONTRACT. THE GENERAL CONTRACTOR IS RESPONSIBLE TO DEFINE AND PROVIDE ALL THE WORK REQUIRED TO COMPLETE THIS PROJECT TO THE TRUE INTENT OF THE CONTRACT WHETHER OR NOT IT IS SPECIFICALLY SHOWN OR SPECIFIED. WHERE THESE DOCUMENTS DO NOT PROVIDE ALL THE INFORMATION NECESSARY FOR THE COMPLETE INSTALLATION OF ANY ITEM, THEN THE MANUFACTURER'S INSTRUCTIONS FOR THE ITEM SHALL BE STRICTLY FOLLOWED. THE GENERAL CONTRACTOR SHALL, SUPPLY AND INSTALL ALL ITEMS, ARTICLES, MATERIALS, INCLUDE ALL LABOR, EQUIPMENT AND TOOLS NECESSARY TO COMPLETE THIS PROJECT AND ALL SYSTEMS SHOWN. TEST AND VERIFY ALL EQUIPMENT INSTALLED UNDER THIS CONTRACT AND INSTRUCT THE OWNER OR OWNER'S AGENT IN THE OPERATION OF THE EQUIPMENT. THE G.C. SHALL THOROUGHLY FAMILIARIZE HIM/HERSELF WITH THE DRAWINGS, SPECIFICATIONS, AND CONDITIONS COVERING THIS JOB. THE G.C. SHALL ADVISE THE OWNER AND THE E.S. OF ANY CONFLICT BETWEEN THESE DRAWINGS AND THE FIELD CONDITIONS BEFORE PROCEEDING WITH THE WORK. THE G.C. SHALL COMPLY WITH ALL STATE AND MUNICIPAL LAWS, ORDINANCES, RULES, AND REGULATIONS OF AUTHORITIES HAVING JURISDICTION. ALL WORK MUST MEET OR EXCEED THE CURRENT BUILDING CODE UNDER THE JURISDICTION FOR WHICH THIS PROJECT IS LOCATED. THE G.C. SHALL FILE ALL NECESSARY APPLICATIONS AND OBTAIN AND PAY FOR ALL PERMITS, AND CERTIFICATES OF APPROVAL PERTAINING TO THE CONSTRUCTION OF THE PREMISES, INCLUDING THE FINAL INSPECTION FOR OCCUPANCY PERMIT, UNLESS OTHERWISE STATED. PERMITS OBTAINED SHALL INCLUDE THE CONNECTIONS TO ALL DENTAL EQUIPMENT AND FIXTURES WHICH ARE TO BE COMPLETED BY THE GENERAL CONTRACTOR. HVAC, SPRINKLER DRAWINGS, CORRESPONDING SPECIFICATIONS OR ANY OTHER DRAWINGS AND SPECIFICATIONS THAT MAY BE REQUIRED FOR LICENSES AND PERMITS ARE TO BE PROVIDED BY OTHERS. HENRY SCHEIN INC. WILL NOT PROVIDE OR PAY FOR THESE SERVICES OR ANY OTHER DRAWINGS AND SPECIFICATIONS THAT MAY BE REQUIRED FOR LICENSES AND PERMITS. ALL MEASUREMENTS SHALL BE CHECKED AT THE JOB SITE. THE GENERAL CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR THE ACCURACY OF FIELD MEASUREMENTS AND CONDITIONS. THEY ARE ALSO RESPONSIBLE FOR THE PROPER MODIFICATIONS TO ANY EXISTING, OR PREVIOUSLY INSTALLED WORK. WRITTEN APPROVAL MUST BE OBTAINED FROM THE E.S. BEFORE ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS AND SPECIFICATIONS ARE MADE. THE G.C. SHALL ASSUME FULL RESPONSIBILITY FOR THE EXECUTION OF HIS/HER WORK AND FOR ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS MADE WITHOUT PRIOR WRITTEN APPROVAL FROM THE OWNER AND/OR THE E.S.. THE COST OF CORRECTIONS RESULTING FROM CHANGES AND/OR DEVIATIONS SHALL BE BORNE BY THE GENERAL CONTRACTOR. A COMPLETE SET OF UP-TO-DATE DRAWINGS MUST BE KEPT AT THE JOB SITE AT ALL TIMES AND ANY CHANGES MUST BE NOTED THEREON AND INITIALED. THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER AND THE OWNER'S AGENT FROM AND AGAINST ALL CLAIMS FOR DAMAGE TO PERSON AND/OR PROPERTY SUFFERED AS A RESULT OF THE PERFORMANCE OF WORK, WHETHER OR NOT, CAUSED BY NEGLIGENCE, AND PAY ANY EXPENSES (INCLUDING, WITHOUT LIMITATIONS, ATTORNEY'S FEES, AND DISBURSEMENTS) INCURRED IN THE CONNECTION THEREWITH. OTHER REQUIREMENTS THE G.C. SHALL PARTICIPATE AT JOB COORDINATION MEETINGS WITH THE HENRY SCHEIN REPRESENTATIVE AND ENSURE ATTENDANCE OF THE APPROPRIATE TRADES. ALL TRADES SHALL DO THEIR OWN CUTTING. THE GENERAL CONTRACTOR SHALL DO ALL PATCHING TO CONFORM TO MATERIAL, TEXTURE, AND SURFACE ALIGNMENT WITH THE ADJOINING SURFACE AND FINAL TOUCH UP OF ALL FINISHED SURFACES. THE GENERAL CONTRACTOR SHALL ENSURE THE PROTECTION OF ALL EQUIPMENT FURNISHED UNDER HIS/HER CONTRACT AND BY OTHERS. THE G.C. SHALL REVIEW ALL CUSTOM CABINETRY, SUCH AT THE RECEPTION DESK, LABORATORY, AND STERILIZATION, WITH THE E.S. FOR ANY DENTAL EQUIPMENT INCOPRORATION. THE G.C. SHALL REMOVE ANY RUBBISH FROM THE CONSTRUCTION SITE AND ENSURE THAT ALL PUBLIC SPACES ARE FREE OF CONSTRUCTION MATERIALS AND DEBRIS THROUGHOUT THE DURATION OF THE CONTRACT. THE G.C. IS RESPONSIBLE FOR THE TOTAL CLEAN UP OF THE JOB SITE UPON COMPLETION OF THEIR WORK. THE GENERAL CONTRACTOR SHALL ISSUE A WRITTEN ONE-YEAR WARRANTY CERTIFICATE ON ALL WORKMANSHIP AND MATERIALS FROM THE DATE OF OCCUPANCY, UNLESS NOTED OTHERWISE IN THE CONSTRUCTION AGREEMENT BETWEEN THE OWNER AND THE G.C.. THIS CERTIFICATE SHALL BIND THE GENERAL CONTRACTOR TO PROMPTLY CORRECT, REPAIR, OR REPLACE, ANY DEFECTIVE EQUIPMENT OR WORKMANSHIP THAT WAS THE RESPONSIBILITY OF THE G.C., WITHOUT COST TO THE OWNER. 5.SEPARATE CONTRACTS BY OWNER THE OWNER RESERVES THE RIGHT TO PERFORM WORK RELATED TO THE PROJECT WITH HIS/HER OWN FORCES, AND TO AWARD SEPARATE CONTRACTS IN CONNECTION WITH OTHER PORTIONS OF THE PROJECT OR ON OTHER WORK ON THE SITE UNDER THESE OR SIMILAR CONDITIONS OF CONTRACT. IF THE GENERAL CONTRACTOR CLAIMS THAT DELAY OR ADDITIONAL COST IS INVOLVED BECAUSE OF SUCH ACTION BY THE OWNER, THE G.C. MUST ENSURE THAT THEIR CLAIM WAS ORIGINALLY PART OF THEIR CONTRACT AGREEMENT. THE G.C. SHALL AFFORD THE OWNER AND SEPARATE CONTRACTORS REASONABLE OPPORTUNITY FOR THE INTRODUCTION AND STORAGE OF THEIR MATERIALS AND EQUIPMENT AND THE EXECUTION OF THEIR WORK. THE G.C. SHALL CONNECT AND COORDINATE THEIR WORK WITH OTHERS AS REQUIRED BY THE CONTRACT DOCUMENTS. ANY COSTS CAUSED BY DEFECTIVE AND/OR ILL-TIME WORK SHALL BE BORNE BY THE PARTY RESPONSIBLE. SEE OWNER OR OWNER'S AGENT FOR NON-DENTAL ITEMS AND AREAS NOT DETAILED IN THESE DRAWINGS (SUCH AS RECEPTION, BUSINESS AREA, OFFICES, STAFF LOUNGE, STORAGE ROOMS, OFFICE-WIDE SOUND SYSTEMS, CONTROLS, ETC.). GENERAL NOTES 1.THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED FOR THIS SPECIFIC PROJECT ONLY, AND SHALL REMAIN THE EXCLUSIVE PROPERTY OF HENRY SCHEIN INC. THESE DRAWINGS AND SPECIFICATIONS MAY NOT BE REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT EXPRESSED WRITTEN CONSENT AND FULL PAYMENT OF ANY ASSOCIATED FEES TO HENRY SCHEIN, INC. 2.ALL COMMUNICATIONS AND COORDINATION WITH TRADES SHALL BE THE RESPONSIBILITY OF THE G.C. UNLESS STATED OTHERWISE IN THE CONTRACT AGREEMENT. 3.THE G.C. MUST SIGN THIS SHEET STIPULATING THAT HE/SHE UNDERSTANDS AND WILL COMPLY WITH ALL SPECIFICATIONS BEFORE THE WORK WILL START. A SIGNED COPY OF THE PLANS ARE TO BE RETURNED TO THE OWNER AND HENRY SCHEIN DENTAL. 4.IT IS THE RESPONSIBILITY OF A SUBCONTRACTOR TO READ AND UNDERSTAND ALL NOTES AND ILLUSTRATIONS PERTAINING TO THEIR TRADE AND HOW THEIR WORK AFFECTS OTHER TRADES. 5.THE SUPPLY AND INSTALL OF THE CABINETS AND COUNTERTOPS, OTHER THAN THOSE SPECIFIED AND/OR CONTRACTED BY HENRY SCHEIN, INC., IS THE RESPONSIBILITY OF THE G.C.. 6.THE OWNER SHALL MAKE ARRANGEMENTS FOR INSTALLATION OF NON-DENTAL SYSTEMS UNDER A SEPARATE CONTRACT BEFORE WALLS ARE ENCLOSED. 7.ROUGH-IN AND FINISH WORK FOR DENTAL EQUIPMENT IS TO BE ACCORDING TO TEMPLATES FURNISHED BY THE MANUFACTURERS OF EQUIPMENT BEING INSTALLED. THE E.S. WILL POSITION THE TEMPLATES IN THEIR PROPER LOCATIONS, AT WHICH TIME ALL SPECIFICATIONS ON THE PLANS WILL BE EXPLAINED TO THE GENERAL CONTRACTOR OR SUBCONTRACTOR(S). ALL SPECIFIED SIZES OF PIPES, TUBING, FITTINGS, ETC., AS WELL AS PROPER HEIGHTS MARKED, MUST BE STRICTLY FOLLOWED. ANY DEVIATIONS ON SIZES OR HEIGHTS OF PIPES, TUBING, AND/OR FITTINGS MUST BE CORRECTED BEFORE THE EQUIPMENT CAN BE INSTALLED, AND ANY SUCH EXTRA EXPENSE WILL BE THE RESPONSIBILITY OF G.C. AND/OR THE SUBTRADE. 8.THE G.C. SHALL SEAL ANY/ALL FLOOR AND FIRE PENETRATIONS MADE BY HENRY SCHEIN INSTALLERS AT THE FINISHING STAGES WITH THE APPROPRIATE MATERIAL. 9.THE G.C. SHALL PROVIDE DOOR THRESHOLDS & DOOR SEALS NECESSARY FOR DENTAL EQUIPMENT SOUND ATTENUATION. 10.THE GENERAL CONTRACTOR SHALL SUPPLY FASTENERS, ANCHORS, ACCESSORIES AND ADHESIVES REQUIRED FOR FABRICATION AND ERECTION OF THE WORK. KEEP EXPOSED FASTENERS TO A MINIMUM, NEATLY LAID OUT AND EVENLY SPACED. FLOOR FINISHES ARE TO BE CONTINUOUS UNDERNEATH MILLWORK AND EQUIPMENT. TRANSITIONS AND VARIATIONS BETWEEN FLOOR FINISHES TO BE SMOOTH AND LEVEL TO REDUCE INJURY WITH USE. PROVIDE 3/4'' (19MM) PLYWOOD SUPPORT BETWEEN STUDS FOR ALL WALLS TO SUPPORT UPPER CABINETRY AND SHELVING, INCLUDING RECEPTION AND ALL TREATMENT ROOMS. WOOD SUPPORTS ABOVE THE CEILING MAY NEED TO BE FIRE RATED, FOLLOW LOCAL CODES. 11.PRIOR TO POURING THE CONCRETE FLOOR AND ENCLOSING ALL WALLS, THE GENERAL CONTRACTOR SHALL CONTACT THE E.S. AND INSTALLATION TECHNICIAN FOR FINAL INSPECTION OF PLUMBING, ELECTRICAL AND WOOD SUPPORTS. 12.ALL LABOR AND MATERIAL NECESSARY FOR CHANGES IN EXISTING PLUMBING, CARPENTRY, AND ELECTRICAL WORK MUST BE DONE AND SUPPLIED BY THE GENERAL CONTRACTOR AND IS NOT INCLUDED IN THE COST OF EQUIPMENT. 13.ALL PLUMBING AND ELECTRICAL LINES ARE TO BE CONCEALED UNLESS OTHERWISE SPECIFIED. 14.THE ELECTRICAL PANEL SHALL BE CONVENIENT AND ACCESSIBLE, MEET ELECTRICAL CODE REQUIREMENTS, AND BE LOCATED IN THE SUITE. LOCATION TO BE APPROVED BY THE OWNER AND LANDLORD. THE G.C. SHALL REVIEW THE LOCATION WITH THE E.S., AS WELL AS THE LOCATIONS OF THE TELEPHONE SYSTEM AND SERVER. 15.HENRY SCHEIN, INC. SHALL NOT BE HELD RESPONSIBLE FOR SUPPLYING UL/ULC OR CSA APPROVAL CERTIFICATES. THE G.C. MAY CONTACT THE MANUFACTURER IF REQUIRED. 16.THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE SPECIFIED TERMINATION BOXES, RECEPTACLES AND ANY HARDWIRE CIRCUITS LOCATED IN CUSTOM DENTAL CABINETRY. THEY ARE ALSO RESPONSIBLE FOR SUPPLYING GFCI RECEPTACLES WHERE REQUIRED BY CODE. 17.THE G.C. IS TO MAKE ARRANGEMENTS FOR TEMPORARY POWER AND/OR DISCONNECTION OF ELECTRICAL AND MECHANICAL SYSTEMS IF AND WHEN REQUIRED. 18.IF MULTIMEDIA SYSTEMS, SUCH AS ENTERTAINMENT TVS, MONITORS, OR NETWORK COMPUTER SYSTEMS, OR SECURITY SYSTEMS ARE SUPPLIED AND INSTALLED BY HENRY SCHEIN, INC., THEN THESE SYSTEMS WILL BE THEIR RESPONSIBILITY. WHEN THESE SYSTEMS, OR OTHER SYSTEMS, ARE NOT PROVIDED BY HENRY SCHEIN, INC., HENRY SCHEIN, INC. SHALL NOT BE HELD RESPONSIBLE FOR THEIR INSTALLATION OR COMMISSIONING. 19.HENRY SCHEIN, INC. WILL ASSEMBLE EQUIPMENT AND, WHERE SPECIFIED WITHIN THESE DRAWINGS, CONNECT TO UTILITIES PROVIDED, SUCH CONNECTIONS BY OTHER TRADES ARE SUPPLIED CORRECTLY AND COMPLETELY (WITH PROPER SHUT-OFF VALVES/FITTINGS/ OUTLETS/TERMINATIONS).  VERIFY ALL CONTRACTOR RESPONSIBILITIES FOR FINAL CONNECTIONS WITH THESE DRAWINGS AND HENRY SCHEIN DENTAL E.S..  DIRECT ANY QUESTIONS REGARDING CONTRACTOR RESPONSIBILITIES TO HENRY SCHEIN DENTAL E.S. PRIOR TO CONSTRUCTION. 20.WHEN APPLICABLE, THE G.C. SHALL BE RESPONSIBLE FOR PROCURING A PLUMBING SUB-CONTRACTOR THAT IS CERTIFIED TO INSTALL NITROUS OXIDE~OXYGEN CONSCIOUS SEDATION SYSTEMS AS DETAILED IN THESE PLANS. HENRY SCHEIN DENTAL IS A NITROUS OXIDE SYSTEM END USER COMPONENT SUPPLIER AND DOES NOT MANUFACTURE OR DESIGN ANY OF THESE SYSTEMS. ANY SYSTEM DESIGN SHOWN ON THESE PLANS BY HENRY SCHEIN DENTAL IS TO BE USED AS AN ILLUSTRATION ONLY FOR THE PURPOSE OF LOCATING END USER OUTLET STATIONS, CYLINDER ROOM MANIFOLD, AND ALARM PANEL. THE FINAL TRUNK SYSTEM INSTALLATION SHALL ADHERE TO THE MECHANICAL ENGINEERING DRAWINGS PREPARED BY A THIRD PARTY. 21.PLUMBING SUBCONTRACTOR SHALL PROVIDE GAS CERTIFICATION CREDENTIALS IN ACCORDANCE WITH ANY REQUESTS BY THE OWNER, GENERAL CONTRACTOR, BUILDING DEPARTMENT, OR HENRY SCHEIN DENTAL PRIOR TO COMMENCING WORK IF ANY TYPE OF NITROUS~OXIDE SYSTEM IS BEING INCORPORATED INTO THE PROJECT. PRIOR TO POURING THE CONCRETE FLOOR AND ENCLOSING ALL WALLS AND CEILINGS, THE GENERAL CONTRACTOR SHALL CONTACT THE E.S. AND INSTALLATION TECHNICIAN FOR FINAL INSPECTION OF PLUMBING, ELECTRICAL AND WOOD SUPPORTS. DENTAL EQUIPMENT DETAILS -I M P O R T A N T N O T E - TH I S D O C U M E N T H A S B E E N P R E P A R E D A S A N I N S T R U M E N T O F PR O F E S S I O N A L S E R V I C E A N D IS N O T A N A R C H I T E C T U R A L P L A N . TH E I D E A S / D E S I G N I N C L U D E D H E R E I N A R E T H E S O L E P R O P E R T Y OF H E N R Y S C H E I N , I N C . A N D A R E P R O T E C T E D U N D E R CO P Y R I G H T . T H E S E P L A N S M A Y N O T B E U S E D O R R E P R O D U C E D WI T H O U T E X P R E S S E D W R I T T E N C O N S E N T O F H E N R Y S C H E I N , I N C . AN D F U L L P A Y M E N T O F A N Y A S S O C I A T E D D E S I G N F E E S . AL L D I M E N S I O N S A R E S U B J E C T T O J O B - S I T E V E R I F I C A T I O N . REVISIONS: HENRY SCHEIN REP: PR O J E C T : LO C A T I O N : SCALE:SHT. SIZE: INT.SQ.FT.= 2023 by HENRY SCHEIN, INC.c REGION: PHONE #: PROJECT START DATE: FINALS START DATE: DRAWN BY: FINALS BY: CHECKED BY: PROJECT NUMBER: P: \ _ A L L R E G I O N S \ M E - B S B o s t o n N o r t h - S o u t h \ G i u l i a n e l l i , M a t t h e w \ G i u l i a n e l l i - 1 G - D 10 9 2 0 W L I N C O L N A V E , W E S T A L L I S , W I 5 3 2 2 7 he n r y s c h e i n i n t e g r a t e d d e s i g n . c o m HEN R Y SCH E I N R IN T E G R A T E D D E S I G N S T U D I O DR . M A T T H E W G I U L I A N E L L I 11 0 K I M B A L L A V E , S T E 2 3 0 SO U T H B U R L I N G T O N , V T 0 5 4 0 3 JASON GOSSELIN ME-BS (617) 719-3343 09/30/2021 09/25/2023 VLL VLL AKL 09/26/2023 VLL --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- N/A 21-2420 (E)WAITING (E)BUSINESS OFFICE (E)IMAGING ALCOVE (E)STERILIZATION (E)LAB(E)PRIVATE OFFICE (E)COAT CLO. (E)COAT STORAGE (E)MECHANICAL (E)PATIENT RESTROOM (E)STAFF RESTROOM / LAUNDRY (E)HYG. ROOM (E)TRE. ROOM (E)TRE. ROOM (E)HYG. ROOM (E)CONFERENCE ROOM IN F I L L IN F I L L NE W A R C H W A Y ELEVATOR, STAIRS, AND PUBLIC RESTROOMS LOCATED IN COMMON CORRIDOR STAFF LOUNGE DIGITAL LAB 42" THIS PLAN HAS BEEN DESIGNED FOR AN OFFICE WHERE NO SEDATION TO MODERATE SEDATION (AS DEFINED BY NFPA 99) IS BEING ADMINISTERED.  IF DEEP SEDATION AND/OR GENERAL ANESTHESIA (AS DEFINED BY NFPA 99) WILL BE ADMINISTERED, THERE MAY BE ADDITIONAL SPACE, EQUIPMENT, AND CODE REQUIREMENTS. A SEDATION QUESTIONNAIRE CAN BE REQUESTED FROM THE HENRY SCHEIN EQUIPMENT SPECIALIST. IT IS THE ARCHITECT/CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ALL CODE RESTRICTIONS & CLEARANCES ARE MET. PHOTO AREA LO C K E R S (E)STORAGE (E) PANTRY SURGICAL SUITE STORAGE ALL NEW TREATMENT ROOM UTILITIES TO BE TIED INTO EXISTING DENTAL MECHANICAL SYSTEMS. SEE HENRY SCHEIN REP. DENTAL CHAIR AND CABINET UTILITIES TO BE LOCATED ON JOB-SITE PER MANUFACTURER'S TEMPLATES. LOCATIONS TO BE APPROVED BY DOCTOR AND HENRY SCHEIN EQUIPMENT SPECIALIST PRIOR TO ROUGH-IN. SA.0 24 x 361/4"=1'-0" FLOOR PLANPROPOSED FLOOR PLAN 1/4"=1'-0" -I M P O R T A N T N O T E - TH I S D O C U M E N T H A S B E E N P R E P A R E D A S A N I N S T R U M E N T O F PR O F E S S I O N A L S E R V I C E A N D IS N O T A N A R C H I T E C T U R A L P L A N . TH E I D E A S / D E S I G N I N C L U D E D H E R E I N A R E T H E S O L E P R O P E R T Y OF H E N R Y S C H E I N , I N C . A N D A R E P R O T E C T E D U N D E R CO P Y R I G H T . T H E S E P L A N S M A Y N O T B E U S E D O R R E P R O D U C E D WI T H O U T E X P R E S S E D W R I T T E N C O N S E N T O F H E N R Y S C H E I N , I N C . AN D F U L L P A Y M E N T O F A N Y A S S O C I A T E D D E S I G N F E E S . AL L D I M E N S I O N S A R E S U B J E C T T O J O B - S I T E V E R I F I C A T I O N . REVISIONS: HENRY SCHEIN REP: PR O J E C T : LO C A T I O N : SCALE:SHT. SIZE: INT.SQ.FT.= 2023 by HENRY SCHEIN, INC.c REGION: PHONE #: PROJECT START DATE: FINALS START DATE: DRAWN BY: FINALS BY: CHECKED BY: PROJECT NUMBER: P: \ _ A L L R E G I O N S \ M E - B S B o s t o n N o r t h - S o u t h \ G i u l i a n e l l i , M a t t h e w \ G i u l i a n e l l i - 1 G - F 2 10 9 2 0 W L I N C O L N A V E , W E S T A L L I S , W I 5 3 2 2 7 he n r y s c h e i n i n t e g r a t e d d e s i g n . c o m HEN R Y SCH E I N R IN T E G R A T E D D E S I G N S T U D I O DR . M A T T H E W G I U L I A N E L L I 11 0 K I M B A L L A V E , S T E 2 3 0 SO U T H B U R L I N G T O N , V T 0 5 4 0 3 JASON GOSSELIN ME-BS (617) 719-3343 09/30/2021 09/25/2023 VLL VLL AKL 09/26/2023 VLL --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- N/A 21-2420 THIS PLAN HAS BEEN DESIGNED FOR AN OFFICE WHERE NO SEDATION TO MODERATE SEDATION (AS DEFINED BY NFPA 99) IS BEING ADMINISTERED.  IF DEEP SEDATION AND/OR GENERAL ANESTHESIA (AS DEFINED BY NFPA 99) WILL BE ADMINISTERED, THERE MAY BE ADDITIONAL SPACE, EQUIPMENT, AND CODE REQUIREMENTS. A SEDATION QUESTIONNAIRE CAN BE REQUESTED FROM THE HENRY SCHEIN EQUIPMENT SPECIALIST. IT IS THE ARCHITECT/CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ALL CODE RESTRICTIONS & CLEARANCES ARE MET. 6 9 35 35 35 ALL NEW TREATMENT ROOM UTILITIES TO BE TIED INTO EXISTING DENTAL MECHANICAL SYSTEMS. SEE HENRY SCHEIN REP. DENTAL CHAIR AND CABINET UTILITIES TO BE LOCATED ON JOB-SITE PER MANUFACTURER'S TEMPLATES. LOCATIONS TO BE APPROVED BY DOCTOR AND HENRY SCHEIN EQUIPMENT SPECIALIST PRIOR TO ROUGH-IN. 39A PLEASE NOTE: A LICENSED CONTRACTOR IS RESPONSIBLE FOR PROVIDING EQUIPMENT BLOCKING. ALL REQUIREMENTS TO BE VERIFIED BY MANUFACTURER'S SPEC SHEETS PROVIDED BY HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. MANUFACTURER'S SPECS SUPERSEDE ANY AND ALL INFORMATION CONTAINED HEREIN. REINFORCEMENT SPECIFICATIONS QU A N T I T Y SP E C . N U M B E R DESCRIPTION DE T A I L 1 1 3 1 6 9 35 39A DENTAL TRACK LIGHT - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. BLOCKING AND ELECTRICAL BY CONTRACTOR(S). WALL MOUNTED INTRAORAL X-RAY HEAD, ARM, AND WALL BRACKET - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. BLOCKING & ELECTRICAL BY CONTRACTOR(S). BLOCKING - UPPER & LOWER SUPPORT - CONTRACTOR TO SUPPLY AND INSTALL BACKING FOR WALL MOUNTED DENTAL UNITS & WALL HUNG CABINETS. SEE HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST FOR EXACT LOCATION. WALL MOUNTED MONITOR - BLOCKING AND ELECTRICAL BY CONTRACTOR(S). EXACT LOCATION PER OWNER AND HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. 6 9 35 39A DIMENSIONS & REINFORCEMENT SPECIFICATIONS 1/4"=1'-0" NEW WALLS TO BE CONSTRUCTED EXISTING WALL TO REMAIN NEW REINFORCEMENT PLACED FOR CEILING-MOUNTED EQUIPMENT. SEE "REINFORCEMENT SPECIFICATION SCHEDULE" FOR MORE INFORMATION. NEW REINFORCEMENT PLACED FOR WALL- MOUNTED EQUIPMENT. SEE "REINFORCEMENT SPECIFICATION SCHEDULE" FOR MORE INFORMATION. DOORWAY HEADER ABOVE, HEIGHT TO BE DETERMINED BY OWNER. OR WALL LEGEND 2. VERIFY ALL DIMENSIONS WITH HENRY SCHEIN DENTAL REP. ON JOBSITE. ON SITE MODIFICATIONS MAY NEED TO BE DONE BY CONTRACTOR, BUT SHOULD BE VERIFIED BY ALL PARTIES INVOLVED. 3. 5/8" GYPSUM WALLBOARD IS RECOMMENDED THROUGHOUT THE OFFICE TO PROVIDE SOUND ATTENUATION & ADDITIONAL PROTECTION AGAINST X-RAY SCATTER RADIATION. ACTUAL NOMINAL 4" TYPICAL DOOR JAMB & 3'-0" DOOR TYPICAL WALL TYPICAL DOOR JAMB (APPLICABLE FOR ANY DOOR STYLE UNLESS DIMENSIONED OTHERWISE) 1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN. THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR CONSTRUCTION. CONSTRUCTION NOTES SA.1 24 x 361/4"=1'-0" REINFORCEMENT PLAN PARTIAL-HEIGHT WALL. SEE PLAN OR CONSTRUCTION DETAILS FOR HEIGHTS. SEE SHEETS SED.1 & SED.2 FOR DENTAL EQUIPMENT DETAILS -I M P O R T A N T N O T E - TH I S D O C U M E N T H A S B E E N P R E P A R E D A S A N I N S T R U M E N T O F PR O F E S S I O N A L S E R V I C E A N D IS N O T A N A R C H I T E C T U R A L P L A N . TH E I D E A S / D E S I G N I N C L U D E D H E R E I N A R E T H E S O L E P R O P E R T Y OF H E N R Y S C H E I N , I N C . A N D A R E P R O T E C T E D U N D E R CO P Y R I G H T . T H E S E P L A N S M A Y N O T B E U S E D O R R E P R O D U C E D WI T H O U T E X P R E S S E D W R I T T E N C O N S E N T O F H E N R Y S C H E I N , I N C . AN D F U L L P A Y M E N T O F A N Y A S S O C I A T E D D E S I G N F E E S . AL L D I M E N S I O N S A R E S U B J E C T T O J O B - S I T E V E R I F I C A T I O N . REVISIONS: HENRY SCHEIN REP: PR O J E C T : LO C A T I O N : SCALE:SHT. SIZE: INT.SQ.FT.= 2023 by HENRY SCHEIN, INC.c REGION: PHONE #: PROJECT START DATE: FINALS START DATE: DRAWN BY: FINALS BY: CHECKED BY: PROJECT NUMBER: P: \ _ A L L R E G I O N S \ M E - B S B o s t o n N o r t h - S o u t h \ G i u l i a n e l l i , M a t t h e w \ G i u l i a n e l l i - 1 G - F 2 10 9 2 0 W L I N C O L N A V E , W E S T A L L I S , W I 5 3 2 2 7 he n r y s c h e i n i n t e g r a t e d d e s i g n . c o m HEN R Y SCH E I N R IN T E G R A T E D D E S I G N S T U D I O DR . M A T T H E W G I U L I A N E L L I 11 0 K I M B A L L A V E , S T E 2 3 0 SO U T H B U R L I N G T O N , V T 0 5 4 0 3 JASON GOSSELIN ME-BS (617) 719-3343 09/30/2021 09/25/2023 VLL VLL AKL 09/26/2023 VLL --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- N/A 21-2420 (E)WAITING (E)BUSINESS OFFICE (E)IMAGING ALCOVE (E)STERILIZATION (E)LAB(E)PRIVATE OFFICE (E)COAT CLO. (E)MECHANICAL (E)PATIENT RESTROOM (E)STAFF RESTROOM / LAUNDRY (E)HYG. ROOM (E)TRE. ROOM (E)TRE. ROOM (E)HYG. ROOM (E)CONFERENCE ROOM ELEVATOR, STAIRS, AND PUBLIC RESTROOMS LOCATED IN COMMON CORRIDOR STAFF LOUNGE DIGITAL LAB THIS PLAN HAS BEEN DESIGNED FOR AN OFFICE WHERE NO SEDATION TO MODERATE SEDATION (AS DEFINED BY NFPA 99) IS BEING ADMINISTERED.  IF DEEP SEDATION AND/OR GENERAL ANESTHESIA (AS DEFINED BY NFPA 99) WILL BE ADMINISTERED, THERE MAY BE ADDITIONAL SPACE, EQUIPMENT, AND CODE REQUIREMENTS. A SEDATION QUESTIONNAIRE CAN BE REQUESTED FROM THE HENRY SCHEIN EQUIPMENT SPECIALIST. IT IS THE ARCHITECT/CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ALL CODE RESTRICTIONS & CLEARANCES ARE MET. PHOTO AREA (E)STORAGE (E) PANTRY SURGICAL SUITE STORAGE 2A 3A ALL NEW TREATMENT ROOM UTILITIES TO BE TIED INTO EXISTING DENTAL MECHANICAL SYSTEMS. SEE HENRY SCHEIN REP. DENTAL CHAIR AND CABINET UTILITIES TO BE LOCATED ON JOB-SITE PER MANUFACTURER'S TEMPLATES. LOCATIONS TO BE APPROVED BY DOCTOR AND HENRY SCHEIN EQUIPMENT SPECIALIST PRIOR TO ROUGH-IN. 11 11 SEE MANUFACTURER CABINET DRAWINGS, SHEET SED.2 FOR ANY ADDITIONAL REQUIREMENTS/ DIMENSIONS. 12B 12B PLEASE NOTE: A LICENSED PLUMBING CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL REQUIRED UTILITIES. ALL REQUIREMENTS TO BE VERIFIED BY MANUFACTURER'S SPEC SHEETS PROVIDED BY HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. MANUFACTURER'S SPECS SUPERSEDE ANY AND ALL INFORMATION CONTAINED HEREIN. PLUMBING SPECIFICATIONS QU A N T I T Y SP E C . N U M B E R DESCRIPTION CO L D W A T E R HO T W A T E R DR A I N CO M P R E S S E D A I R NA T U R A L G A S VA C U U M N2 O OX Y G E N NI T R O G E N VE N T UTILITIES DE T A I L 1 1 2 2 2A 3A 11 12B UTILITY CENTER – SELF-CONTAINED WATER. SEE DETAIL(S). SELF-CONTAINED WATER. ALL UTILITIES MUST CONFORM TO PREVAILING LOCAL CODES. UTILITY CENTER - SELF-CONTAINED WATER. SEE DETAIL(S). ALL UTILITIES MUST CONFORM TO PREVAILING LOCAL CODES. MODULAR SINKS & FAUCETS - SINK AND FAUCET SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BY PLUMBER. FINAL CONNECTIONS BY PLUMBER. WATER POWERED TAP MASTER FAUCET CONTROL - FROM (12B) TO (11) OR (11A). SUPPLIED BY HENRY SCHEIN DENTAL, INSTALLED BY PLUMBER. ●●● ● ●● 2A 3A 12B PROPOSED PLUMBING PLAN 1/4"=1'-0"SP.1 24 x 361/4"=1'-0" DENTAL PLUMBING PLAN SEE SHEETS SED.1 & SED.2 FOR DENTAL EQUIPMENT DETAILS PLUMBING NOTES 5. WATER PRESSURE MUST NOT EXCEED 50 PS1 AT ALL DENTAL UNITS. 6. ALL PLUMBING MUST CONFORM TO LOCAL PREVAILING CODES. 3. FOLLOW MANUFACTURER'S TEMPLATES FOR EXACT REQUIREMENTS FOR ANY EQUIPMENT SUPPLIED BY HENRY SCHEIN DENTAL. CONSULT WITH HENRY SCHEIN DENTAL REP FOR ADDITIONAL INFORMATION. 1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN. THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR CONSTRUCTION. 2. EXACT EQUIPMENT LOCATIONS MUST BE JOB SITE VERIFIED BY THE HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. 7. REFER TO ARCHITECT'S DRAWINGS FOR PLUMBING REQUIREMENTS IN ALL AREAS NOT INDICATED ON THIS PLAN. ALL DIMENSIONS NOTED ON PLAN ARE TO THE CENTERLINE OF PLUMBING OR UTILITY CENTER (UNLESS SHOWN OTHERWISE) 4. DENTAL AIR IS SUPPLIED THROUGH USE OF A DENTAL AIR COMPRESSOR/SUPPLY SYSTEM AND IS PERMITTED TO BE USED AS A SUPPORT GAS FOR DRIVING DENTAL TOOLS AND SUPPLYING AIR-DRIVEN EQUIPMENT AS DESCRIBED WITHIN NFPA 99. DENTAL AIR IS NOT A MEDICAL GAS. WYE FITTING MAIN LINE 45 ELBOWS BRANCH LINE CONFIGURATION SUB FLOOR THE VACUUM PIPING LAYOUT HAS A LARGE EFFECT ON THE EFFICIENCY AND RELIABILITY OF THE DENTAL VACUUM SYSTEM. REFER TO MANUFACTURER'S PRE-INSTALLATION GUIDE PROVIDED BY HENRY SCHEIN EQUIPMENT SPECIALIST (FOR SPECIFIC SIZING OF STUB-UP, TRUNK, AND BRANCH LINES. IT IS HIGHLY RECOMMENDED THAT VACUUM LINES RUN UNDERNEATH DENTAL EQUIPMENT BY MEANS OF TRENCHING/ CORING (CONCRETE SLAB) OR IN SUB FLOOR (BASEMENT/ CRAWL SPACE). ALL LINES ARE TO BE DESIGNED WITH PVC PIPING UNLESS DICTATED BY LOCAL CODES TO USE COPPER OR CAST IRON. TO ENSURE OPTIMUM VACUUM PERFORMANCE, INSTALL MAIN LINE DIRECTLY BELOW THE DENTAL CHAIR, CABINET OR WALL JUNCTION BOX TO REDUCE OR ELIMINATE BRANCH LINE RUNS WHEREVER POSSIBLE. I. STUB-UP TERMINATE VACUUM TRUNK LINE IN MECHANICAL ROOM. PLUMBING CONTRACTOR TO PROVIDE FPT ADAPTOR ON END OF STUB-OUT FROM FLOOR OR WALL. SIZE OF ADAPTOR TO BE DETERMINED BY TRUNK AND PUMP INTAKE PIPE SIZES. SEE DETAILS THIS SET & MANUFACTURER TEMPLATES PROVIDED BY HENRY SCHEIN EQUIPMENT REP. IN THE CASE OF DUAL TRUNK LINE SYSTEM, PROVIDE ENOUGH SPACE BETWEEN STUB-UPS TO INSTALL TEES ON BOTH LINES. 2. TRUNK LINE(S) VACUUM TRUNK LINES(S) TO BE SUPPORTED EVERY 6'-0" TO PREVENT SAG AND SLOPED A MINIMUM OF 1/4" PER 10'-0" TOWARD THE VACUUM PUMP. 3. BRANCH LINE(S) BRANCH LINES ARE TO HAVE "SWEEPING" 90 DEGREE TURNS TO AVOID VACUUM LOSS. A "WYE" FITTING SHOULD BE USED TO JOIN BRANCH LINES TO THE TRUNK LINE. SPECIAL NOTE: IF VACUUM LINES ENCROACH ON EITHER A WALL OR COLUMN FOOTING, USE 45 DEGREE ELBOWS TO PIPE AROUND FOOTING SO PIPE REACHES PROPER LOCATION. FLOW PUMP TO FLOW DO NOT PIPE TRUNK LINE IN A SERIES MANNER LOOPING FROM J-BOX TO J-BOX. A CONTINUOUS TRUNK LINE MUST BE MAINTAINED FROM THE PUMP TO THE FURTHEST J-BOX USING BRANCH LINES OFF OF THE TRUNK LINE TO PICK UP EACH VACUUM OUTLET. TRUNK LINE MAY FOLLOW DRAIN LINE TRENCHES WITHIN REASON. USE ONLY 45 DEGREE EL'S. DO NOT USE ANY 90 DEGREE EL'S. ALL SUB FLOOR SCH 40 PVC CONNECTIONS ARE TO BE PLUMBED WITH 45 DEGREE EL'S USING DETAIL A FOR TEEING BRANCH LINE CONNECTIONS INTO TRUNK LINE. DETAIL A WYE FITTING (USE FOR ALL SUB FLOOR INTERSECTIONS) VACUUM NOTES -I M P O R T A N T N O T E - TH I S D O C U M E N T H A S B E E N P R E P A R E D A S A N I N S T R U M E N T O F PR O F E S S I O N A L S E R V I C E A N D IS N O T A N A R C H I T E C T U R A L P L A N . TH E I D E A S / D E S I G N I N C L U D E D H E R E I N A R E T H E S O L E P R O P E R T Y OF H E N R Y S C H E I N , I N C . A N D A R E P R O T E C T E D U N D E R CO P Y R I G H T . T H E S E P L A N S M A Y N O T B E U S E D O R R E P R O D U C E D WI T H O U T E X P R E S S E D W R I T T E N C O N S E N T O F H E N R Y S C H E I N , I N C . AN D F U L L P A Y M E N T O F A N Y A S S O C I A T E D D E S I G N F E E S . AL L D I M E N S I O N S A R E S U B J E C T T O J O B - S I T E V E R I F I C A T I O N . REVISIONS: HENRY SCHEIN REP: PR O J E C T : LO C A T I O N : SCALE:SHT. SIZE: INT.SQ.FT.= 2023 by HENRY SCHEIN, INC.c REGION: PHONE #: PROJECT START DATE: FINALS START DATE: DRAWN BY: FINALS BY: CHECKED BY: PROJECT NUMBER: P: \ _ A L L R E G I O N S \ M E - B S B o s t o n N o r t h - S o u t h \ G i u l i a n e l l i , M a t t h e w \ G i u l i a n e l l i - 1 G - F 2 10 9 2 0 W L I N C O L N A V E , W E S T A L L I S , W I 5 3 2 2 7 he n r y s c h e i n i n t e g r a t e d d e s i g n . c o m HEN R Y SCH E I N R IN T E G R A T E D D E S I G N S T U D I O DR . M A T T H E W G I U L I A N E L L I 11 0 K I M B A L L A V E , S T E 2 3 0 SO U T H B U R L I N G T O N , V T 0 5 4 0 3 JASON GOSSELIN ME-BS (617) 719-3343 09/30/2021 09/25/2023 VLL VLL AKL 09/26/2023 VLL --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- N/A 21-2420 (E)WAITING (E)BUSINESS OFFICE (E)IMAGING ALCOVE (E)STERILIZATION (E)LAB(E)PRIVATE OFFICE (E)COAT CLO. (E)MECHANICAL (E)PATIENT RESTROOM (E)STAFF RESTROOM / LAUNDRY (E)HYG. ROOM (E)TRE. ROOM (E)TRE. ROOM (E)HYG. ROOM (E)CONFERENCE ROOM ELEVATOR, STAIRS, AND PUBLIC RESTROOMS LOCATED IN COMMON CORRIDOR STAFF LOUNGE DIGITAL LAB THIS PLAN HAS BEEN DESIGNED FOR AN OFFICE WHERE NO SEDATION TO MODERATE SEDATION (AS DEFINED BY NFPA 99) IS BEING ADMINISTERED.  IF DEEP SEDATION AND/OR GENERAL ANESTHESIA (AS DEFINED BY NFPA 99) WILL BE ADMINISTERED, THERE MAY BE ADDITIONAL SPACE, EQUIPMENT, AND CODE REQUIREMENTS. A SEDATION QUESTIONNAIRE CAN BE REQUESTED FROM THE HENRY SCHEIN EQUIPMENT SPECIALIST. IT IS THE ARCHITECT/CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ALL CODE RESTRICTIONS & CLEARANCES ARE MET. PHOTO AREA (E)STORAGE (E) PANTRY SURGICAL SUITE STORAGE 2A 3A 56 9 9A 9B 19 4A ALL NEW TREATMENT ROOM UTILITIES TO BE TIED INTO EXISTING DENTAL MECHANICAL SYSTEMS. SEE HENRY SCHEIN REP. DENTAL CHAIR AND CABINET UTILITIES TO BE LOCATED ON JOB-SITE PER MANUFACTURER'S TEMPLATES. LOCATIONS TO BE APPROVED BY DOCTOR AND HENRY SCHEIN EQUIPMENT SPECIALIST PRIOR TO ROUGH-IN. SEE MANUFACTURER CABINET DRAWINGS, SHEET SED.2 FOR ANY ADDITIONAL REQUIREMENTS/ DIMENSIONS. 39A PLEASE NOTE: A LICENSED ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL REQUIRED UTILITIES. ALL REQUIREMENTS TO BE VERIFIED BY MANUFACTURER'S SPEC SHEETS PROVIDED BY HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. MANUFACTURER'S SPECS SUPERSEDE ANY AND ALL INFORMATION CONTAINED HEREIN. ELECTRICAL SPECIFICATIONS QU A N T I T Y SP E C . N U M B E R DESCRIPTION PO W E R DE D I C A T E D C I R C U I T LO W V O L T A G E C O N T R O L DA T A D R O P UTILITIES DE T A I L 1 1 1 1 1 1 1 1 1 1 2A 3A 4A 5 6 9 9A 9B 19 39A UTILITY CENTER – SELF-CONTAINED WATER. SEE DETAIL(S). SELF-CONTAINED WATER. ALL UTILITIES MUST CONFORM TO PREVAILING LOCAL CODES. UTILITY CENTER - SELF-CONTAINED WATER. SEE DETAIL(S). ALL UTILITIES MUST CONFORM TO PREVAILING LOCAL CODES. 2" SUB-FLOOR CONDUIT - SUB-FLOOR PIPE CHASE WITH PULL-STRING SUPPLIED & INSTALLED BY ELECTRICIAN. SWEEPING 90 DEGREE BENDS ONLY. STUB-UP FLUSH WITH SUB-FLOOR AT EACH END, MARK LOCATION AT FINISH. DENTAL CHAIR RECEPTACLE - SUPPLIED & INSTALLED BY ELECTRICIAN. DENTAL TRACK LIGHT - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. BLOCKING AND ELECTRICAL BY CONTRACTOR(S). WALL MOUNTED INTRAORAL X-RAY HEAD, ARM, AND WALL BRACKET - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. BLOCKING & ELECTRICAL BY CONTRACTOR(S). X-RAY MASTER CONTROL – SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. ELECTRICIAN TO SUPPLY AND INSTALL PIPE CHASE WITH PULL-STRING TO (9) LOCATION WHEN (9A) IS REMOTE. VERIFY SUPPLIER OF WIRING WITH HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. X-RAY REMOTE EXPOSURE BUTTON – SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. ELECTRICIAN TO SUPPLY AND INSTALL PIPE CHASE WITH PULL-STRING TO (9A) OR (9C) LOCATION. VERIFY SUPPLIER OF EXPOSURE BUTTON AND WIRING WITH HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. 3D PRINTING SYSTEM – PRINTER, WASH/DRY AND CURING UNITS SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL.  5’-0” OF CLEAR COUNTER SPACE RECOMMENDED.  2’-4” CLEARANCE REQUIRED BETWEEN COUNTERTOP AND UPPER CABINETS.  POWER BY ELECTRICIAN.  SEE DETAIL. WALL MOUNTED MONITOR - BLOCKING AND ELECTRICAL BY CONTRACTOR(S). EXACT LOCATION PER OWNER AND HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. 115V 115V 115V 115V 115V 115V SEE MFG. SPECS 20A ● ● ● ● 2A 3A 4A 5 6 9 9B 19 39A PROPOSED ELECTRICAL PLAN 1/4"=1'-0" *SPECIFICATIONS MAY INCLUDE DATA, SEE ELECTRICAL SCHEDULE THIS SHEET SE.1 24 x 361/4"=1'-0" DENTAL ELECTRICAL PLAN SEE SHEETS SED.1 & SED.2 FOR DENTAL EQUIPMENT DETAILS ELECTRICAL NOTES 5. ADDITIONAL CONVENIENCE OUTLETS REQUIRED ON JOBSITE ARE THE RESPONSIBILITY OF ELECTRICAL CONTRACTORS. FOLLOW LOCAL CODE RESTRICTIONS. 4. GFCI PROTECTION OR REDUNDANT GROUND IN DENTAL CHAIR RECEPTACLES, DENTAL UTILITY CABINETS AND ANY OTHER AREAS REQUIRED BY LOCAL CODE IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 2. EXACT EQUIPMENT LOCATIONS MUST BE JOB SITE VERIFIED BY THE HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST. 3. FOLLOW MANUFACTURER'S TEMPLATES FOR EXACT REQUIREMENTS FOR ANY EQUIPMENT SUPPLIED BY HENRY SCHEIN DENTAL. CONSULT WITH HENRY SCHEIN DENTAL REP FOR ADDITIONAL INFORMATION. 1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN. THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR CONSTRUCTION. 7. ALL COMPUTER NETWORKING AND WORKSTATIONS MUST BE SPECIFIED BY CUSTOMER'S COMPUTER SUPPLIER. IF HENRY SCHEIN WILL BE SUPPLYING THE COMPUTERS & NETWORKING COMPONENTS, SEE SHEET SE.2 FOR THE OFFICE TECHNOLOGY PLAN. 8. CONTRACTOR TO PROVIDE AND INSTALL ALL EXIT SIGNS, EMERGENCY LIGHTING AND FIRE SUPPRESSION & DETECTION SYSTEMS AS PER ARCHITECT'S DRAWINGS AND LOCAL CODE. 9. REFER TO ARCHITECT'S DRAWINGS FOR ELECTRICAL REQUIREMENTS IN ALL AREAS NOT INDICATED ON THIS PLAN. ALL DIMENSIONS NOTED ON PLAN ARE TO THE CENTERLINE OF RECEPTACLE OR UTILITY CENTER (UNLESS SHOWN OTHERWISE) 6. ALL CONDUIT LOCATIONS SHOULD BE VERIFIED WITH OWNER AND HENRY SCHEIN REP PRIOR TO ROUGH-IN. -I M P O R T A N T N O T E - TH I S D O C U M E N T H A S B E E N P R E P A R E D A S A N I N S T R U M E N T O F PR O F E S S I O N A L S E R V I C E A N D IS N O T A N A R C H I T E C T U R A L P L A N . TH E I D E A S / D E S I G N I N C L U D E D H E R E I N A R E T H E S O L E P R O P E R T Y OF H E N R Y S C H E I N , I N C . A N D A R E P R O T E C T E D U N D E R CO P Y R I G H T . T H E S E P L A N S M A Y N O T B E U S E D O R R E P R O D U C E D WI T H O U T E X P R E S S E D W R I T T E N C O N S E N T O F H E N R Y S C H E I N , I N C . AN D F U L L P A Y M E N T O F A N Y A S S O C I A T E D D E S I G N F E E S . AL L D I M E N S I O N S A R E S U B J E C T T O J O B - S I T E V E R I F I C A T I O N . REVISIONS: HENRY SCHEIN REP: PR O J E C T : LO C A T I O N : SCALE:SHT. SIZE: INT.SQ.FT.= 2023 by HENRY SCHEIN, INC.c REGION: PHONE #: PROJECT START DATE: FINALS START DATE: DRAWN BY: FINALS BY: CHECKED BY: PROJECT NUMBER: P: \ _ A L L R E G I O N S \ M E - B S B o s t o n N o r t h - S o u t h \ G i u l i a n e l l i , M a t t h e w \ G i u l i a n e l l i - 1 G - F 2 10 9 2 0 W L I N C O L N A V E , W E S T A L L I S , W I 5 3 2 2 7 he n r y s c h e i n i n t e g r a t e d d e s i g n . c o m HEN R Y SCH E I N R IN T E G R A T E D D E S I G N S T U D I O DR . M A T T H E W G I U L I A N E L L I 11 0 K I M B A L L A V E , S T E 2 3 0 SO U T H B U R L I N G T O N , V T 0 5 4 0 3 JASON GOSSELIN ME-BS (617) 719-3343 09/30/2021 09/25/2023 VLL VLL AKL 09/26/2023 VLL --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- N/A 21-2420 NOTES: 1.DETAIL PROVIDED FOR UTILITY REQUIREMENTS. REFER TO MANUFACTURER'S INSTALLATION GUIDE FOR ADDITIONAL INFORMATION. HENRY SCHEIN DENTAL REP WILL PROVIDE INSTALLATION TEMPLATE UPON REQUEST. 2.INSTALLATION MUST CONFORM TO ALL LOCAL ELECTRICAL AND PLUMBING CODES. 3.ALL UTILITIES HEREIN TO BE SUPPLIED & INSTALLED BY LICENSED CONTRACTORS. FINAL CONNECTIONS TO EQUIPMENT BY HENRY SCHEIN DENTAL. 4.ALL VALVES, BOXES AND PIPES FROM FLOOR MUST BE NO HIGHER THAN 5" A.F.F. 5.ALL PLUMBED SYSTEMS MUST BE FLUSHED CLEAN OF ANY DEBRIS PRIOR TO EQUIPMENT INSTALLATION. 2A SINK CABINET UTILITY CENTER NOT TO SCALE ELEVATION VIEW COMPRESSED AIR: 1/2" SUPPLY LINE FROM COMPRESSOR BY PLUMBER. STUB-OUT FROM WALL 1”-2”. TERMINATE WITH 3/8” ANGLE VALVE. PRESSURE 100 PSI MAX. ELECTRICAL: 16" FLEX CONDUIT WITH TWO GANG BOX & 115V QUAD OUTLET BY ELECTRICIAN. A E MAX. HEIGHT OF UTILITIES WHEN STUB-UP FROM FLOOR A E CL SINK UTILITIES SINK WATER LINES MAY BE COMBINED. SEE HENRY SCHEIN REP. NOTES: 1.DETAIL PROVIDED FOR UTILITY REQUIREMENTS. REFER TO MANUFACTURER'S INSTALLATION GUIDE FOR ADDITIONAL INFORMATION. HENRY SCHEIN DENTAL REP WILL PROVIDE INSTALLATION TEMPLATE UPON REQUEST. 2.INSTALLATION MUST CONFORM TO ALL LOCAL ELECTRICAL AND PLUMBING CODES. 3.ALL UTILITIES HEREIN TO BE SUPPLIED & INSTALLED BY LICENSED CONTRACTORS. FINAL CONNECTIONS TO EQUIPMENT BY HENRY SCHEIN DENTAL. 4.ALL VALVES, BOXES AND PIPES FROM FLOOR MUST BE NO HIGHER THAN 5 1/4" A.F.F. 5.ALL PLUMBED SYSTEMS MUST BE FLUSHED CLEAN OF ANY DEBRIS PRIOR TO EQUIPMENT INSTALLATION. 3A DCI EDGE SERIES 4/SERIES 5 CABINET UTILITIES NOT TO SCALE TOP VIEW COMPRESSED AIR: 1/2" SUPPLY LINE FROM COMPRESSOR BY PLUMBER. STUB-UP FROM FLOOR 1”-2”. TERMINATE WITH 3/8” ANGLE VALVE. PRESSURE 100 PSI MAX. ELECTRICAL: 16" FLEX CONDUIT WITH TWO GANG BOX & 115V QUAD OUTLET BY ELECTRICIAN. MAX DRAW: 15A CENTRAL VACUUM: 5/8" RISER BY PLUMBER (SCH. 40 PVC OR TYPE M COPPER). TERMINATE 1"-2" A.F.F. A E V UTILITIES TO BE RUN IN FLOOR OR WALL BASED ON SITE CONDITIONS CL C A V CABINET BASE CUT-OUTS WITHIN CABINET BASE PVC PIPE CHASE WITH PULL-STRING BY ELECTRICIAN. 6" MIN. RADIUS FOR ALL BENDS. STUB-UP FLUSH WITH SUB-FLOOR, MARK LOCATION AT FINISH. QUANTITY OF CHASE TERMINATIONS WILL VARY, SEE SHEET SE.1 FOR SIZES & LOCATIONS. C 4A SUB-FLOOR CHASE NOT TO SCALE FOLLOW LOCAL CODES FOR ALL WORK. TERMINATE CONDUIT IN BASE OF CABINET. 2" CONDUIT - PIPE CHASE WITH PULL-STRING SUPPLIED AND INSTALLED BY CONTRACTOR. 6" MIN. SWEEPING BENDS. STUB-UP FLUSH WITH SUB-FLOOR, MARK LOCATION OF PIPE AT FINISH. SEE CHAIR/CABINET/CART UTILITY CENTER DETAIL FOR CONDUIT TERMINATION LOCATION. COORDINATE WITH HENRY SCHEIN REP. TOP VIEW 5 RECESSED CHAIR OUTLET NOT TO SCALE NOTES: 1.DETAIL PROVIDED FOR UTILITY REQUIREMENTS. REFER TO CHAIR MANUFACTURER'S INSTALLATION GUIDE FOR ADDITIONAL INFORMATION. HENRY SCHEIN DENTAL REP WILL PROVIDE INSTALLATION TEMPLATE UPON REQUEST. 2.INSTALLATION MUST CONFORM TO ALL LOCAL ELECTRICAL CONDES. 3.ALL UTILITIES HEREIN TO BE SUPPLIED & INSTALLED BY LICENSED CONTRACTORS. FINAL CONNECTIONS TO EQUIPMENT BY HENRY SCHEIN DENTAL. RECESSED QUAD OUTLET WITH BRASS COVER PLATE FLUSH WITH FINISHED FLOOR BY ELECTRICIAN. COORDINATE EXACT FINISH WITH ARCHITECT AND OWNER. CL CL TOE OF CHAIR HEAD OF CHAIR 120 PRODUCT SPECIFICATIONS 1.25 - 5A 78 -200 NOTES: 1.DETAIL PROVIDED FOR BLOCKING & UTILITY REQUIREMENTS. REFER TO MANUFACTURER'S INSTALLATION GUIDE FOR ADDITIONAL INFORMATION. 2.INSTALLATION MUST CONFORM TO ALL LOCAL FRAMING AND ELECTRICAL CODES. 3.PROVIDE ADEQUATE BLOCKING AND STRUCTURAL BRACING TO SUPPORT A PULL OF 500 LBS. BLOCKING MUST BE LEVEL. 4.MOUNTING MATERIALS SUPPLIED AND INSTALLED BY CONTRACTOR. 5.FINAL CONNECTIONS TO BE MADE BY HENRY SCHEIN DENTAL. NOMINAL VAC RATING VOLTAGE MIN/MAX FULL LOAD AMPS WEIGHT (LBS) 108/132 SUPPORT STRUCTURE AND BRACING SPECIFIED BY ENGINEER, SUPPLIED AND INSTALLED BY CONTRACTOR. FINISHED CEILING 6 TYPICAL TRACK MOUNTED DENTAL LIGHT NOT TO SCALE MOUNT BLOCKING TIGHT TO FINISHED CEILING. PACK AREA BETWEEN BLOCKING AND CEILING WITH PLYWOOD AS NEEDED. BLOCKING - SINGLE 2x12, 8' LONG. REINFORCE WITH 2x4 STUDS ON BOTH SIDES. FOR NON-COMBUSTABLE CONSTRUCTION, FRT LUMBER MAY BE USED OR BLOCKING MAY BE WRAPPED IN FIRECODE CORE GYP. BRD. FOLLOW LOCAL CODES. TRACK LIGHT PALETTE, SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL AT FINISH. FRONT VIEW SIDE VIEW ELECTRICIAN TO PROVIDE JUNCTION BOX & 115V POWER FEED WITH 6' WHIP ABOVE CEILING FOR TRACK LIGHT. SEE HENRY SCHEIN REP FOR FINAL TERMINATION POINT, DRILL HOLE & FEED WHIP THROUGH BACKING INTO TRACK LIGHT FOR FINAL CONNECTIONS. 9 MIDMARK PREVA X-RAY NOT TO SCALE FOLLOW LOCAL CODES FOR ALL WORK. DETAIL PROVIDED FOR BLOCKING & UTILITY REQUIREMENTS. REFER TO MANUFACTURER'S INSTALLATION GUIDE FOR ADDITIONAL INFORMATION. THE WALL FABRICATION AND ATTACHMENTS TO THE BUILDING STRUCTURE MUST BE CAPABLE OF WITHSTANDING A LOAD MOMENT OF 850 FT. LBS., 100 LB. SHEAR LOAD AND A 500 LB. WITHDRAWAL FORCE AT EACH OF THE MOUNTING BOLTS. FRAMING SHOULD ALLOW ALL FOUR MOUNTING BOLTS TO ENTER SOLID WOOD. MOUNTING MATERIALS SUPPLIED AND INSTALLED BY CONTRACTOR. STACKED 2 x 4 OPTION (TOP VIEW) 1/2" OR 5/8" PLYWOOD (BASED ON FRAMING TYPE) 5/8" GYP. BRD. AT FINISH MOUNTING PLATE AND BOLT FASTEN LAYERS TOGETHER TO AVOID SHIFTING. BOLTS MUST FASTEN TO THE LONG SIDE OF 2 x 4 STUD (AS SHOWN). 2 X 4 S. YELLOW PINE NO. 2 2 X 4 S. YELLOW PINE NO. 2 PROPERLY SECURE FRAMING TO STRUCTURE ABOVE FOLLOWING LOCAL CODES TWO GANG BOX WITH 115V POWER FEED ON DEDICATED 20A CIRCUIT BY ELECTRICIAN. PROVIDE 18" WHIP. X-RAY MAX DRAW: 5A SINGLE-GANG JUNCTION BOX AND CONDUIT TO ABOVE CEILING (OR PER CODE) WITH PULL-STRING BY ELECTRICIAN TO 9A (IF REMOTE) OR 9B. 25' OF CABLE PROVIDED, SEE HENRY SCHEIN REP. 4 X 4 DOUGLAS FIR-LARCH POSTS BY CONTRACTOR. SEE STACKED 2 X 4 OPTION DETAIL BELOW IF STRAIGHT, SOLID 4 X 4 POSTS ARE NOT AVAILABLE. X-RAY MOUNTING PLATE SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL AT FINISH. SECURE PLATE USING 3/8"X4" FULLY-THREADED LAG SCREWS. FINAL CONNECTIONS BY HENRY SCHEIN DENTAL. 9B X-RAY EXPOSURE BUTTON NOT TO SCALE FOLLOW LOCAL CODES FOR ALL WORK. DETAIL PROVIDED FOR UTILITY REQUIREMENTS. REFER TO MANUFACTURER'S INSTALLATION GUIDE FOR ADDITIONAL INFORMATION. EXPOSURE BUTTON SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL AT FINISH. SINGLE-GANG JUNCTION BOX & CONDUIT TO ABOVE CEILING (OR PER CODE) WITH PULL-STRING BY ELECTRICIAN TO 9A OR 9C LOCATION. SEE SHEET SE.1. 19 SPRINTRAY PRO S 3D PRINTER SYSTEM NOT TO SCALE DATA: SINGLE GANG BOX AT 44" A.F.F. WITH 1" CONDUIT AND PULL STRING TO 4" ABOVE FINISHED CEILING BY CONTRACTOR. DATA DROP & RJ45 OUTLET BY OWNER'S I.T. COMPANY. PRO S UNIT 15W x 20H x 21D 2.0A DRAW (2)SINGLE GANG BOXES & 115V DUPLEX OUTLETS BY ELECTRICIAN. COMBINED MAX. AMP DRAW: 5.1A 3D PRINTER UNITS SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. WASH/DRY UNIT 18W x 12H x 14D 0.8A DRAW CURE UNIT 13W x 12H x 14.75D 1.5-2.3A DRAW 100 - 240 PRODUCT SPECIFICATIONS .08 - 2.3 NOMINAL VAC RATING FULL LOAD AMPS WEIGHT (LBS) HERTZ 50/60 SEE MANUF. 12B TAPMASTER FAUCET CONTROL (SINK CABINET) NOT TO SCALE FOLLOW LOCAL CODES FOR ALL WORK. DETAIL PROVIDED FOR UTILITY REQUIREMENTS. REFER TO MANUFACTURER'S INSTALLATION GUIDE FOR ADDITIONAL INFORMATION. TAPMASTER FAUCET CONTROL SYSTEM SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. 1/2" COLD & HOT WATER SUPPLY LINES FOR SINK BY CONTRACTOR. STUB-OUT FROM WALL AND TERMINATE WITH A 3/8" ANGLE VALVE. TAPMASTER VALVE BLOCKS. CONNECTIONS BY HENRY SCHEIN DENTAL. TAPMASTER KICK PLATE SED.1 24 x 36SEE DETAIL DENTAL EQUIP. DETAILS -I M P O R T A N T N O T E - TH I S D O C U M E N T H A S B E E N P R E P A R E D A S A N I N S T R U M E N T O F PR O F E S S I O N A L S E R V I C E A N D IS N O T A N A R C H I T E C T U R A L P L A N . TH E I D E A S / D E S I G N I N C L U D E D H E R E I N A R E T H E S O L E P R O P E R T Y OF H E N R Y S C H E I N , I N C . A N D A R E P R O T E C T E D U N D E R CO P Y R I G H T . T H E S E P L A N S M A Y N O T B E U S E D O R R E P R O D U C E D WI T H O U T E X P R E S S E D W R I T T E N C O N S E N T O F H E N R Y S C H E I N , I N C . AN D F U L L P A Y M E N T O F A N Y A S S O C I A T E D D E S I G N F E E S . AL L D I M E N S I O N S A R E S U B J E C T T O J O B - S I T E V E R I F I C A T I O N . REVISIONS: HENRY SCHEIN REP: PR O J E C T : LO C A T I O N : SCALE:SHT. SIZE: INT.SQ.FT.= 2023 by HENRY SCHEIN, INC.c REGION: PHONE #: PROJECT START DATE: FINALS START DATE: DRAWN BY: FINALS BY: CHECKED BY: PROJECT NUMBER: P: \ _ A L L R E G I O N S \ M E - B S B o s t o n N o r t h - S o u t h \ G i u l i a n e l l i , M a t t h e w \ G i u l i a n e l l i - 1 G - D 10 9 2 0 W L I N C O L N A V E , W E S T A L L I S , W I 5 3 2 2 7 he n r y s c h e i n i n t e g r a t e d d e s i g n . c o m HEN R Y SCH E I N R IN T E G R A T E D D E S I G N S T U D I O DR . M A T T H E W G I U L I A N E L L I 11 0 K I M B A L L A V E , S T E 2 3 0 SO U T H B U R L I N G T O N , V T 0 5 4 0 3 JASON GOSSELIN ME-BS (617) 719-3343 09/30/2021 09/25/2023 VLL VLL AKL 09/26/2023 VLL --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- N/A 21-2420 PROPERLY SECURE FRAMING TO STRUCTURE ABOVE FOLLOWING LOCAL CODES 35 UPPER & LOWER CABINETRY BLOCKING NOT TO SCALE 3/4" PLYWOOD BLOCKING BY CONTRACTOR. MOUNT FLUSH WITH STUD FACE. HEIGHTS TO BE COORDINATED WITH CABINET MAKER & HENRY SCHEIN REP (FOR MANUFACTURED CABINETS). FOLLOW LOCAL CODES FOR ALL WORK. PROPERLY SECURE FRAMING TO STRUCTURE ABOVE FOLLOWING LOCAL CODES 39A WALL MOUNTED TELEVISION NOT TO SCALE BLOCKING BY CONTRACTOR. MOUNT FLUSH WITH STUD FACE. TYPE OF BLOCKING & HEIGHTS TO BE COORDINATED WITH OWNER & OWNER'S I.T. COMPANY. FOLLOW LOCAL CODES FOR ALL WORK. SINGLE GANG BOX & 115V DUPLEX OUTLET BY ELECTRICIAN. TWO GANG BOX & 112" CONDUIT WITH PULL-STRING TO 6" ABOVE CEILING BY ELECTRICIAN. 100/110 - 120/220 PRODUCT SPECIFICATIONS 55 NOMINAL VAC RATING FULL LOAD AMPS WEIGHT (LBS) 203TORQUE (FT-LBS) HERTZ 50/60 SEE MANUF. SED.2 24 x 36SEE DETAIL DENTAL EQUIP. DETAILS -I M P O R T A N T N O T E - TH I S D O C U M E N T H A S B E E N P R E P A R E D A S A N I N S T R U M E N T O F PR O F E S S I O N A L S E R V I C E A N D IS N O T A N A R C H I T E C T U R A L P L A N . TH E I D E A S / D E S I G N I N C L U D E D H E R E I N A R E T H E S O L E P R O P E R T Y OF H E N R Y S C H E I N , I N C . A N D A R E P R O T E C T E D U N D E R CO P Y R I G H T . T H E S E P L A N S M A Y N O T B E U S E D O R R E P R O D U C E D WI T H O U T E X P R E S S E D W R I T T E N C O N S E N T O F H E N R Y S C H E I N , I N C . AN D F U L L P A Y M E N T O F A N Y A S S O C I A T E D D E S I G N F E E S . AL L D I M E N S I O N S A R E S U B J E C T T O J O B - S I T E V E R I F I C A T I O N . REVISIONS: HENRY SCHEIN REP: PR O J E C T : LO C A T I O N : SCALE:SHT. SIZE: INT.SQ.FT.= 2023 by HENRY SCHEIN, INC.c REGION: PHONE #: PROJECT START DATE: FINALS START DATE: DRAWN BY: FINALS BY: CHECKED BY: PROJECT NUMBER: P: \ _ A L L R E G I O N S \ M E - B S B o s t o n N o r t h - S o u t h \ G i u l i a n e l l i , M a t t h e w \ G i u l i a n e l l i - 1 G - D 10 9 2 0 W L I N C O L N A V E , W E S T A L L I S , W I 5 3 2 2 7 he n r y s c h e i n i n t e g r a t e d d e s i g n . c o m HEN R Y SCH E I N R IN T E G R A T E D D E S I G N S T U D I O DR . M A T T H E W G I U L I A N E L L I 11 0 K I M B A L L A V E , S T E 2 3 0 SO U T H B U R L I N G T O N , V T 0 5 4 0 3 JASON GOSSELIN ME-BS (617) 719-3343 09/30/2021 09/25/2023 VLL VLL AKL 09/26/2023 VLL --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- --/--/----- N/A 21-2420