Loading...
HomeMy WebLinkAboutZP-24-006 - 1503-1505 Dorset Street 2/21/20241505Dorset LLC 44 acres ZP-24-006 Admin Officer Note: New structure address is 1503 Dorset Street. Existing structure (ADU) will retain It's 1505 Dorset Street address. Verified by pdfFiller 12/03/2023 Arvid E Dahlstrom 12/03/2023 02/07/2024 SEQ NRP construct new single family home and convert existing home to an ADU 3,084.95 see attached February 21, 2024 March 7, 2024 February 20, 2024 180 MARKET STREET, SOUTH BURLINGTON, VERMONT | (802) 846-4107 | WWW.SOUTHBURLINGTONVT.GOV Conditions of approval for Zoning Permit #ZP-24-006 1505 Dorset Street 1. Per Section 12.04.F of the Land Development Regulations the following is prohibited in the Habitat Block area of 1505 Dorset Street. a) The clearing of trees and understory vegetation is prohibited. b) The creation of new lawn areas is prohibited. c) Snow storage areas are prohibited. 2. The address of the new single family home is 1503 Dorset Street. The existing structure (ADU) will retain its 1505 Dorset Street address. 3. Performance standards. If ledge is discovered during the course of work,, the permit holder will provide the Administrative Officer with the following information as outlined in Section 3.13(E) prior to commencing any ledge and/or blasting work. Evidence of application for state and/or federal permits for the handling of potentially hazardous conditions, and/or the following information, at minimum, may be required for determination of compliance with performance standards or for conditional use review of potentially hazardous conditions: i. Description of proposed machinery, operations, and products. ii. Amount and nature of materials to be used. iii. Mechanisms and techniques to be used in restricting the emission of any hazardous and objectionable elements, as well as projected or actual emission levels. iv. Method of delivery and disposal of any hazardous elements. v. Other information as may be necessary. 4. In addition to the specific standards listed above, all other performance standards listed in the Land Development Regulations remain in effect. 5. The City’s Public Nuisance Ordinance is applicable. Planning & Zoning Accessory Dwelling Unit Questionnaire Applicant (Print): _Jerad Dahlstrom______________________ Subject Property Address: _1505 Dorset Street South Burlington VT 05403_____________ South Burlington permits single-family homes to have one (1) accessory dwelling unit (ADU), sometimes called “mother-in-law” apartments as long as they are clearly subordinate to the primary home on the lot. It is an ADU if it has separate sleeping, sanitary and kitchen facilities from the primary home and has its own access/egress, apart from the primary home. Please answer the following questions about your proposed accessory dwelling unit (ADU). Y N 1. Will the ADU be (select only one): a) Built entirely within the existing Single-Family home, X b) Built as part of an expansion to the Single-Family home, X c) Built within an existing accessory structure, or X d) Built within a new or expanded accessory structure? X 2. Will the property owner reside in one of the dwelling units (primary or accessory)? X 3. Please indicate that you understand that one of the dwelling units must be owner-occupied. Your signature below will certify this understanding. X 4. Please confirm that you have submitted Wastewater Allocation application to cover the additional wastewater flow generated by the unit. X Please answer the following questions about your proposed accessory dwelling unit. Sq. Ft. 5. What is the size (in sf) of the habitable area of existing single-family home? 7,489 6. What is the size (in sf) of the proposed accessory dwelling unit? 1,845 Notes (add any additional information): New home to be constructed will be the primary home and the existing structure will become the ADU. Wastewater permit has been approved by the state and is on file with the city of South Burlington. The existing home will be clearly subordinate to the new home in two main ways. The new home will be at a higher elevation on the property and larger and more visible. Second, the new home will be the first home reached when driving up the driveway from Dorset street. Applicant Signature ____Jerad Dahlstrom //Signed Digitally__ Date ___10/4/2023_______ Updated: 02/16/2022 Page 1 of 2 *** Below are the South Burlington Land Development Regulations relevant to ADU’s: Section 3.11 Accessory Dwelling Units A. One (1) accessory dwelling unit that is clearly subordinate to a single-family dwelling shall be permitted within or appurtenant to a single-family dwelling on the same lot, provided there is compliance with all the following: (1) The lot is owner-occupied. (2) The accessory unit does not exceed thirty percent (30%) of the total habitable area of the single-family dwelling or 900 square feet, whichever is greater. (3) Adequate wastewater capacity is available to service the accessory unit, as demonstrated by issuance of a Wastewater Allocation or on-site wastewater permit pursuant to the South Burlington Ordinance Regulating the use of Public and Private Sanitary Sewerage and Stormwater Systems. (4) The accessory unit meets all dimensional requirements applicable to a single-family home on that same parcel. (5) The Accessory Dwelling Unit and associated coverage shall be included in the computation of building and lot coverage. (6) A zoning permit shall be required for each accessory residential unit B. Supplemental allowance as a Conditional Use. An Accessory Dwelling Unit (ADU), or portion thereof that is proposed to be within the required setback applicable to a singlefamily home may be approved as a Conditional Use, in accordance with Section 14.11. Section 14.11 H Accessory Dwelling Units Supplemental Allowance An Accessory Dwelling Unit (ADU), or portion thereof that is proposed to be within the required setback applicable to a single-family home may be approved as a Conditional Use, subject to the following: (1) The ADU must comply with all provisions of Section 3.11 (Accessory Dwelling Units) except setback standards; (2) The ADU shall only be situated where an accessory structure on the lot may be placed; (3) The ADU, and any portion thereof, must not exceed 15’ in height; (4) The ADU must not exceed 600 s.f. gross floor area; (5) The principal entry to the ADU must not be oriented a side or rear lot line; and, (6) The proposed encroachment of the ADU must not have an undue adverse affect on: (a) views of adjoining and/or nearby properties; (b) access to sunlight of adjoining and/or nearby properties; and, (c) privacy of adjoining and/or nearby properties. This questionnaire needs to be included with any Zoning Permit application for an ADU. Both documents can be submitted through email at: planning@sbvt.gov or by visiting the Planning & Zoning Office, 3rd floor at 180 Market Street, in South Burlington. Feel free to contact us using the email above or you can call us at (802) 846-4106. Updated: 02/16/2022 Page 2 of 2 180 Market Street South Burlington, VT 05403 tel 802.846.4106 fax 802.846.4101 www.sburl.com February 14, 2024 Postmaster US Postal Service 60 White Street South Burlington, VT 05403 (via email: 05401BurlingtonVT@USPS.gov) RE: New Street and Address To whom it may concern: The City of South Burlington has approved construction of a new home and conversion of the existing home to an accessory dwelling unit. To support emergency response, the new home has been assigned a new address of 1503 Dorset Street. I respectfully request that you add the address to your system as soon as possible and that you please let the appropriate persons within your organization know that the address has been added in order to facilitate uninterrupted service Thanks very much for your help, and if you have any questions, please don’t hesitate to contact me at the City of South Burlington (802) 846-4106. Sincerely, Marla Keene, P.E. Development Review Planner E9-1-1 Coordinator Cc: City of South Burlington Tax Dept., Fire Dept., Dispatch, Clerks Office (via email) SITE PLAN TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON Scale: 1/8" = 1'-0" SITE PLAN (NEW STRUCTURE)1 Scale: 1/32" = 1'-0" SITE PLAN (EXISTING STRUCTURE)2 Master Bedroom = 455 sq ftMaster Bathroom = 84.5 sq ft Bedroom #2 = 114 sq ftSpare Bathroom = 50 sq ftForyer / Dining Room = 270 sq ftFamily Room = 279.5 sq ftLaundry Room = 27 sq ftLiving Room / Kitchen = 441 sq ftMudroom = 85.5 sq ftHall = 38.5 sq ft Total finished = 1,845 sq ft Unfinished RoomsBasement = 437 sq ftGarage = 639 sq ft 1505 Dorset Street existing structure floor plan Bedroom #2 9.5 x 12 Lin e n C l o s e t 5 x 2 Spare Bathroom 5 x 10 Hallway 3.5 x 12 Master Bedroom 26 x 17.5 Master Bath 11 x 10 Walk in Closet Finished Square footage Entry Foryer and Dining room 22.5 x 12 La u n d r y R o o m 9 x 3 Family Room 13 x 21.5 Mudroom 9 x 9.5 Living Room Kitchen 21 x 21 2 Car Garage Unfinished COVER SHEET TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON DAHLSTROM RESIDENCE 1505 DORSET STREET C - COVER SHEET 01 - SITE PLAN 02 - FOUNDATION PLAN 03 - FIRST FLOOR PLAN 04 - SECOND FLOOR PLAN 05 - FIRST FLOOR FRAMING. T.B.D. 06 - SECOND FLOOR FRAMING. T.B.D. 07- ELEVATIONS 08 - ELEVATIONS 09 - ROOF PLAN VIEW THE FOLLOWING GENERAL NOTES SHALL APPLY TO ALL DRAWINGS CONTAINED IN THIS DRAWING SET AS LISTED IN THE DRAWING INDEX ON THE COVER SHEET: 1.ALL WORK REPRESENTED IN THE DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT SHALL BE CONSIDERED AS PART OF THE WORK REQUIRED BY THE CONTRACT DOCUMENTS. WHERE THE CONTRACTOR FINDS ANY DISCREPANCY IN THESE REQUIREMENTS, PRIORTY SHALL BE GIVEN IN THE FOLLOWING ORDER: 1.1.THE CONTRACT 1.2.THE WRITTEN SPECIFICATIONS, EITHER IN THE DRAWINGS OR A SEPARATE DOCUMENT 1.3.SCHEDULES 1.4.LARGE SCALE DRAWINGS 1.5.SMALL SCALE DRAWINGS ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF TIM GRAVELIN. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR EXECUTING THE WORK IN ACCORDANCE WITH THESE CONTRACT DOCUMENTS AND SHALL BE LIABLE FOR ANY DEVIATIONS FROM THE DRAWINGS OR SPECIFICATIONS/NOTES. 3.CONTRACTOR SHALL BE RESPONSIBLE FOR EXECUTING THE WORK IN COMPLIANCE WITH ALL APPLICABLE BUILDING CODES, REGULATIONS AND ORDINANCES AS DEFINED BY THE LOCAL BUILDING AUTHORITIES. 4.CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY LOCAL BUILDING AUTHORITIES. 5.CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY AND CONTROL OVER THE METHODS, MEANS, TECHNIQUES, SEQUENCES, AND COORDINATION OF ALL PORTIONS OF THE WORK. 6.CONTRACTOR SHALL USE ONLY WRITTEN DIMENSIONS OR NOTES ON COMPONENT RELATIONSHIPS TO DETERMINE LAYOUT. DRAWINGS SHALL NOT BE SCALED TO DETERMINE THIS INFORMATION. SHOULD A DISCREPANCY BE FOUND, OR CLARIFICATION REQUIRED, THE CONTRACTOR SHALL CONTACT TIM GRAVELIN FOR DETERMINATION 7.DIMENSIONS SHOWN ARE TO FACE OF STUD OR FACE OF STRUCTURE (FOS) OR FACE OF MASONRY (FOM) UNLESS NOTED OTHERWISE. 8.ALL SYMBOLS AND ABBREVIATIONS SHALL BE INTERPRETED IN ACCORDANCE WITH THE DEFINITIONS AND LEGENDS PROVIDED ON THE COVER SHEET AND IN THE STRUCTURAL NOTES. BUILDING DATA PER UNIT: SQUARE FOOTAGES BASEMENT 2264 SQUARE FEET FIRST FLOOR 2264 SQUARE FEET SECOND FLOOR 1883 SQUARE FEET GARAGES 1078 SQUARE FEET TOTAL FINISHED 7489 SQUARE FEET DRAWING INDEX SITE PLAN TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON Scale: 1/8" = 1'-0" SITE PLAN (NEW STRUCTURE)1 Scale: 1/32" = 1'-0" SITE PLAN (EXISTING STRUCTURE)2 FOUNDATION PLAN Scale: 1/4" = 1'-0" FOUNDATION PLAN1 TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON FLOOR PLANS Scale: 1/4" = 1'-0" FIRST FLOOR PLAN1 TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON ELECTRICAL LAYOUT Scale: 1/4" = 1'-0" SECOND FLOOR PLAN1 TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON ELEVATIONS TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON Scale: 1/4" = 1'-0" BACK EELVATION2 Scale: 1/4" = 1'-0" FRONT ELEVATION1 ELEVATIONS TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON Scale: 1/4" = 1'-0" RIGHT EELVATION2 Scale: 1/4" = 1'-0" LEFT ELEVATION1 ROOF PLAN TGDESIGNS TIM GRAVELIN, CIVIL ENGINEERARCHITECTURAL PLANS,ENGINEERING DOCUMENTSSOUTH BURLINGTON, vt.802-310-6727 1505 DORSET STREET SOUTH BURLINGTON Scale: 1/4" = 1'-0" ROOF PLAN VIEW1 State of Vermont Agency of Natural Resources Department of Environmental Conservation Drinking Water and Groundwater Protection Division WASTEWATER SYSTEM AND POTABLE WATER SUPPLY PERMIT LAWS/REGULATIONS INVOLVED 10 V.S.A. Chapter 64, Potable Water Supply and Wastewater System Permit Wastewater System and Potable Water Supply Rules, Effective April 12, 2019 Regional Offices – Montpelier/Essex Jct./Rutland/Springfield/St. Johnsbury Permittee(s): 1505 Dorset LLC 1505 Dorset Street South Burlington, VT 05403 Permit Number: WW-4-5962 This permit affects the following property/properties in the City of South Burlington, Vermont: Lot Parcel SPAN Acres Book(s)/Page(s)# 1 0570-01505 600-188-11693 44.00 Book:1601 Page(s):110 This application, consisting of the construction of a four (4) bedroom single family residence utilizing a proposed on-site wastewater disposal system and a proposed on-site drilled well water supply on an existing 44.00-acre parcel with an existing two (2) bedroom single family residence utilizing an existing on-site wastewater disposal system and an existing municipal water system connection located at 1505 Dorset Street in the City of South Burlington, Vermont, is hereby approved under the requirements of the regulations named above subject to the following conditions. Any person aggrieved by this permit may appeal to the Environmental Court within 30 days of the date of issuance of this permit in accordance with 10 V.S.A. Chapter 220 and the Vermont Rules of Environmental Court Proceedings. 1. GENERAL 1.1 The permittee is responsible for recording this permit in the City of South Burlington Land Records within 30 days of issuance of this permit and prior to the conveyance of any lot subject to the jurisdiction of this permit. 1.2 The permittee is responsible for recording the design and installation certifications and other documents that are required to be filed under these Rules or under a permit condition in the City of South Burlington Land Records. 1.3 Each assign or successor in interest shall be shown a copy of the Wastewater System and Potable Water Supply Permit and the stamped plan(s) prior to the conveyance of a lot. 1.4 The landowner is responsible for establishing any easement(s) shown on the approved plans. The land deeds that establish and transfer ownership of the approved lot(s) shall allow future owner(s) the right to construct, maintain, and repair the wastewater and/or potable water supply systems approved herein. If the landowner does not properly execute said easement(s), this permit becomes null and void for any subject lot conveyed without easement(s). 1.5 By acceptance of this permit, the permittee agrees to allow representatives of the State of Vermont access to the property covered by the permit, at reasonable times, for the purpose of ascertaining compliance with the Vermont environmental and health statutes and regulations, and permit conditions. 1.6 This permit does not relieve the landowner from obtaining all other approvals and permits from other State Agencies or Departments, or local officials prior to construction. 2. CONSTRUCTION 2.1 Construction shall be completed as shown on the plans and/or documents prepared by O’Leary – Burke Civil Associates, PLC (David Burke, Licensed Designer and Bryan W. Currier, P.E.) with the stamped plans listed as follows: Wastewater System and Potable Water Supply Permit WW-4-5962 Page 2 of 3 Title Sheet # Plan Date Revision Overall Plan Sheet 1 04/12/2023 N/A 20' Scale Location Plan Sheet 2 04/12/2023 08/14/2023 20' Scale Location Plan (2) Sheet 3 04/12/2023 08/14/2023 Water & Sewer Details Sheet 4 06/28/2023 N/A Water & Sewer Details (2) Sheet 5 06/28/2023 08/14/2023 2.2 Construction of wastewater systems or potable water supplies, or buildings or structures (as defined by the Wastewater System and Potable Water Supply Rules), or campgrounds, not depicted on the stamped plans, or identified in this permit, is not allowed without prior approval by the Drinking Water and Groundwater Protection Division. 2.3 No buildings, roads, water pipes, sewer services, earthwork, re-grading, excavation, or other construction that might interfere with the operation of a wastewater system or a potable water supply are allowed on or near the site-specific wastewater system, wastewater replacement area, or potable water supply depicted on the stamped plans. Adherence to all isolation distances that are set forth in the Wastewater System and Potable Water Supply Rules is required. 3. INSPECTIONS 3.1 No permit issued by the Secretary shall be valid for a substantially completed potable water supply and wastewater system until the Secretary receives a signed and dated certification from a qualified Vermont Licensed Designer (or where allowed, the installer) on a Secretary-approved form that states: “I hereby certify that, in the exercise of my reasonable professional judgment, the installation-related information submitted is true and correct and the potable water supply and wastewater system were installed in accordance with the permitted design and all permit conditions, were inspected, were properly tested, and have successfully met those performance tests.” or which satisfies the requirements of §1-311 of the referenced rules. 3.2 Prior to the use of the potable water supply, the permittee shall test the water for Arsenic, Escherichia coli (E. coli), Fluoride, Lead, Manganese, Nitrate as N, Nitrite as N, Total Coliform Bacteria, Uranium, Adjusted Gross Alpha Particle Activity, Chloride, Sodium, Iron, Odor and pH. The Lead sample shall be a first-draw. All water quality tests shall be conducted at a laboratory certified by the Vermont Department of Health (a list of which can be found on the VDH website). Results of the water tests shall be submitted to the Vermont Department of Health prior to use or within 60 days of the submission of the Installation Certification required in Condition 3.1, whichever comes first. 4. DESIGN FLOW 4.1 Lot use and design flows (gpd) shall correspond to the following: Lot Building Building Use / Design Flow Basis Wastewater Water 1 Existing 2-bedroom single family residence 280 280 1 Proposed 4-bedroom single family residence 490 490 5. WASTEWATER SYSTEM 5.1 The existing two (2) bedroom single family residence is approved with an existing wastewater system. No changes shall be made to the existing wastewater system unless otherwise exempt without prior approval from the Drinking Water and Groundwater Protection Division. 5.2 A future replacement wastewater area for the existing two (2) bedroom single family residence is identified on the stamped plan(s). There shall be no construction or other activities that will affect the suitability of this area for the design and construction of a wastewater system. 5.3 Prior to the construction of a replacement wastewater system for the existing two (2) bedroom single family residence in the replacement area, the landowner shall file an application with the Drinking Water and Groundwater Protection Division pursuant to the Wastewater System and Potable Water Supply Rules. Wastewater System and Potable Water Supply Permit WW-4-5962 Page 3 of 3 5.4 Prior to construction or site work, a designer shall flag the proposed leachfield, and the owner shall maintain the flags until commencement of construction of the system. 5.5 Should a wastewater system fail and not qualify as a minor repair or for an exemption, the landowner shall engage a qualified Licensed Designer to evaluate the cause of the failure and submit an application to the Drinking Water and Groundwater Protection Division, and obtain approval thereof, prior to correcting the failure. 5.6 This permit does not relieve the permittee of the obligations of Title 10, Chapter 48, Subchapter 4, for the protection of groundwater. 6. POTABLE WATER SUPPLY 6.1 The existing two (2) bedroom single family residence is approved with an existing municipal water system connection. 6.2 Prior to construction or site work, a designer shall flag the center of the proposed potable water source and the owner shall maintain the flag until commencement of construction of the source. 6.3 Should the potable water supply fail and not qualify as a minor repair or for an exemption, the landowner shall engage a qualified Licensed Designer to evaluate the cause of the failure and submit an application to the Drinking Water and Groundwater Protection Division, and obtain approval thereof, prior to correcting the failure. Julia S. Moore, Secretary Agency of Natural Resources Dated August 14, 2023 By ________________________________ Allison Lowry Environmental Analyst VI Essex Junction Regional Office Drinking Water and Groundwater Protection Division cc: O’Leary – Burke Civil Associates, PLC E E E E E E WWW W W W WW W W W W W W W W W W FM FM FM FM FM FM FM FM 1"=100' BWC DWB DWB OBCA 5-20-231505 Dorset St South Burlington Vermont 1 Location Map Scale: 1" = 1000' Nowland Farm Drive Do r s e t S t r e e t Cider Mill Dr Old Cross Road Old S c h o o l h o u s e R d Wi l l o w b r o o k L n Sadie Lane Link Rd CIVIL ASSOCIATES, PLC O'LEARY-BURKE ESSEX JCT., VTPHONE: 878-9990 FAX: 878-9989E-MAIL: obca@olearyburke.com 13 CORPORATE DRIVE Legend Project Boundary Other Property Line Existing Contour Line Proposed Contour Line Existing Water Line Proposed Sewer Forcemain 50' Wetland Buffer Overall Plan FM W 2021-74A WW SITE Existing Lot44 AC Drinking Water & Groundwater Protection Division THIS IS SUBJECT TO PROVISIONS OR CONDITIONS LISTED IN PERMIT Permit #: Date: WW-4-5962 08/14/2023 W W W W W W W W W W W W W W W W W W FM F M F M FMFMFMFM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM 1"=20' BWC DWB DWB OBCA 5-20-2023 South Burlington Vermont 2 Location Map Scale: 1" = 1000' Nowland Farm Roa d Do r s e t S t r e e t Cider Mill Dr Old Cross Road Old S c h o o l h o u s e R d Wi l l o w b r o o k L n Sadie Lane Link Rd CIVIL ASSOCIATES, PLC O'LEARY-BURKE ESSEX JCT., VT PHONE: 878-9990 FAX: 878-9989 E-MAIL: obca@olearyburke.com 13 CORPORATE DRIVE 1505 Dorset St 20' Scale Location Plan 2021-74A WW SITE PROPOSED MAX. 4-BR HOUSE SITE +/- 386 387 385 384 383 382 381 380 379 386 387 385 384 383 382 381 380 379 Drinking Water & Groundwater Protection Division THIS IS SUBJECT TO PROVISIONS OR CONDITIONS LISTED IN PERMIT Permit #: Date: WW-4-5962 08/14/2023 W W W W W W W W W W FM FM FM F M FMFMFMFMFM FM FM FM FM FM F M F M F M FMFMFMFM 1"=20' BWC DWB DWB OBCA 5-20-2023 South Burlington Vermont 3 CIVIL ASSOCIATES, PLC O'LEARY-BURKE ESSEX JCT., VT PHONE: 878-9990 FAX: 878-9989 E-MAIL: obca@olearyburke.com 13 CORPORATE DRIVE 1505 Dorset St 20' Scale Plan 2021-74A WW Drinking Water & Groundwater Protection Division THIS IS SUBJECT TO PROVISIONS OR CONDITIONS LISTED IN PERMIT Permit #: Date: WW-4-5962 08/14/2023 W W W W W W W W FM FMFM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM BWC DWB DWB OBCA 5-20-2023 South Burlington Vermont 4 CIVIL ASSOCIATES, PLC O'LEARY-BURKE ESSEX JCT., VTPHONE: 878-9990 FAX: 878-9989E-MAIL: obca@olearyburke.com 13 CORPORATE DRIVE 1505 Dorset St Water & SewerDetails 2021-74A WW PROPOSED MAX. 4-BR HOUSE SITE +/- Drinking Water & Groundwater Protection Division THIS IS SUBJECT TO PROVISIONS OR CONDITIONS LISTED IN PERMIT Permit #: Date: WW-4-5962 08/14/2023 BWC DWB DWB OBCA 5-20-2023 South Burlington Vermont 5 CIVIL ASSOCIATES, PLC O'LEARY-BURKE ESSEX JCT., VT PHONE: 878-9990 FAX: 878-9989 E-MAIL: obca@olearyburke.com 13 CORPORATE DRIVE 1505 Dorset St Water & Sewer Details (2) 2021-74A WW Drinking Water & Groundwater Protection Division THIS IS SUBJECT TO PROVISIONS OR CONDITIONS LISTED IN PERMIT Permit #: Date: WW-4-5962 08/14/2023