HomeMy WebLinkAboutSD-24-02 - Plans - Non-Record - 0850 Hinesburg RoadThis document was created by an application that isn’t licensed to use novaPDF.
Purchase a license to generate PDF files without this notice.
SITE
WETLAND ADVISORY
LAYER
N/F
BURLINGTON
PROPERTIES LTD
(Dynapower)
HI
N
E
S
B
U
R
G
R
O
A
D
GRAVEL DRIVE
D
D
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
S
S
G
G
BUILDING HEIGHT
30.7'
BUILDING HEIGHT
48.7'
W
W
S
S
S
S
S
S
S
D
W
W
W
W
S
S
S
W
W
G
G
S
G G
G
G
G G
G
G
SMH
r=370.85
i=358.93
SMH
r=366.22
i=357.72
SMH
r=363.22
i=356.57
SMH
SMH
SMH
INV.=365.41
24
"
R
C
P
INV.=363.63
PAVED
PARKING
AREA
PAVED
PARKING
AREA
CB
SMH
r=372.68
N/F
LANDRUM
(Lane Press)
N/F
WATERLOO REAL
ESTATE GROUP, LLC
(DR Power Equipment)
385
385
38
5
38
5
38
5
391
391
39
1
391
39
1
39
1
389
38
9
38
9
38
9
38
9
390
390
39
0
39
0
39
0
39
8
398
39
8
39
8
383
383
38
3
38
3
38
3
38
2
38
2
38
2
38
2
38
2
39
7
397
39
7
39
7
379
37
9
379
379
379
396
39
6
39
6
39
6
39
6
39
5
395
39
5
39
5
38
1
381
38
1
38
1
38
1
38
0
380
38
0
38
0
38
0
393
39
3
39
3
39
3
394
39
4
39
4
394
39
4
3
9
2
392
39
2
39
2
3
9
2
388
388
38
8
3
8
8
38
8
36
2
362
362
362
36
1
361
3
6
0
378
378
37
8
378
378
378
377
377
377
37
7
37
7
41
9
41
9
41
9
419
41
5
41
5
4
1
5
415
415
4
1
7
417
41
7
417
4
1
7
41
6
41
6
41
6
416
41
6
41
1
411
41
1
411
3
9
9
39
9
39
9
39
9
40
6
40
6
40
6
40
6
386
386
38
6
38
6
38
6
40
1
40
1
40
1
40
1
42
2
422
42
2
4
0
0
40
0
40
0
40
0
421
4
2
1
42
1
4
2
1
421
42
1
42
0
420
420
420
4
1
8
41
8
4
1
8
41
8
41
8
40
4
404
404
40
4
4
0
3
403
403
40
3
4
1
4
414
414
414
413
41
3
4
1
3
41
3
413
41
2
41
2
41
2
412
412
41
0
41
0
410
41
0
410
4
0
9
409
40
9
409
40
8
40
8
40
8
40
8
40
5
40
5
40
5
40
5
405
40
7
40
7
40
7
40
7
40
2
402
40
2
40
2
384
384
38
4
38
4
38
4
376
376
3
7
6
376
376
371
371
37
1
371
37
1
371
366
36
6
3
6
6
366
369
36
9
36
9
36
9
369
369
387
387
38
7
38
7
38
7
368
368
36
8
368
368
36
8
36
8
367
36
7
36
7
36
7
367
367
375
375
3
7
5
375
37
5
375
374
374
37
4
37
4
37
4
373
37
3
37
3
373
3
7
3
372
3
7
2
372
37
2
3
7
2
370
37
0
37
0
37
0
3
7
0
365
36
5
36
5
36
5
36
5
365
364
36
4
36
4
364
364
363
3
6
3
36
3
363
36
3
POOL
SILO
HUT
TEL.
SHED
GARAGE
HOUSE
HOUSE
HOUSE
GARAGE
WATER
VLV.HYD.
WATER
VLV.TEL.
POLE
C
O
N
C
R
E
T
E
HYD.
RET
A
I
N
I
N
G
W
A
L
L
CLASS III
WETLANDS
20' SEWER
EASEMENT
SOLAR PANELS
SHED
GR
A
V
E
L
D
R
I
V
E
50'
WETLAND
BUFFER
50'
BUFFE
R
PRESUMED WETLAND (AS
SHOWN ON PREVIOUS
LANE PRESS PLANS)
0.24 ACRES WITHIN
POSSIBLE WETLAND BUFFER
N/F
835 HINESBURG RD. LLC
SS
SS
S
SS
APPROX.
SEPTIC SYSTEM
(TYP)
W
W
W
W
W
W
W
W
W
W
WATER
SERVICE
(TYP)
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
E N G I N E E R I N G S U R V E Y
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLANNIN G ENVIRON MENTAL
0
Feet
Graphic Scale
40 80 120
15°±
VT
G
r
i
d
M
a
g
n
e
t
i
c
Existing Conditions
Plan
C1-01
----
23-015
DJG
WGM Associates
850, 900 & 950 Hinesburg Road
South Burlington, Vermont 05407
EXISTING CONDITIONS NOTES:
1.THE PURPOSE OF THE EXISTING CONDITIONS PLAN IS TO DEPICT READILY APPARENT PERTINENT EXISTING
CONDITIONS AS OF THE DATE OF SURVEY.
2.BEARINGS SHOWN ARE BASED UPON VERMONT GRID NORTH USING VTVRS CORS STATION.
3.VERTICAL DATUM IS BASED ON NAVD88 (GEIOD 18). A CARLSON BRx7 RTK GPS UNIT WAS EMPLOYED FOR THESE
OBSERVATIONS.
4.COORDINATE SYSTEM IS BASED ON VERMONT STATE PLANE (U.S. SURVEY FEET).
5.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS SHOWN ARE BASED ON RESEARCH,
UTILITY PLANS PROVIDED BY OTHERS, AND/OR SURFACE EVIDENCE ENCOUNTERED AND WERE OBTAINED IN A
MANNER CONSISTENT WITH THE ORDINARY STANDARD OF PROFESSIONAL CARE AND HAVE NOT BEEN
INDEPENDENTLY VERIFIED BY THE OWNER OR THE DESIGN ENGINEER. ADDITIONAL UTILITIES NOT SHOWN MAY
EXIST. ENGINEER SHALL BE NOTIFIED IF ANY DISCREPANCIES ARE ENCOUNTERED. ACTUAL LOCATION OF
UNDERGROUND UTILITIES MAY VARY. DIGSAFE MUST BE CONTACTED PRIOR TO ANY EXCAVATION. CALL
1-888-DIG SAFE (344-7233) OR CALL 811.
6.PERIMETER BOUNDARIES SHOWN HEREON FROM TAX MAP INFORMATION AND OTHER RESOURCES, AND DOES
NOT DEPICT A FORMAL BOUNDARY SURVEY.
PROJECT LOCATION