Loading...
HomeMy WebLinkAboutSD-24-02 - Plans - Non-Record - 0850 Hinesburg RoadThis document was created by an application that isn’t licensed to use novaPDF. Purchase a license to generate PDF files without this notice. SITE WETLAND ADVISORY LAYER N/F BURLINGTON PROPERTIES LTD (Dynapower) HI N E S B U R G R O A D GRAVEL DRIVE D D S S S S S S W W W W W W W W W W W S S G G BUILDING HEIGHT 30.7' BUILDING HEIGHT 48.7' W W S S S S S S S D W W W W S S S W W G G S G G G G G G G G SMH r=370.85 i=358.93 SMH r=366.22 i=357.72 SMH r=363.22 i=356.57 SMH SMH SMH INV.=365.41 24 " R C P INV.=363.63 PAVED PARKING AREA PAVED PARKING AREA CB SMH r=372.68 N/F LANDRUM (Lane Press) N/F WATERLOO REAL ESTATE GROUP, LLC (DR Power Equipment) 385 385 38 5 38 5 38 5 391 391 39 1 391 39 1 39 1 389 38 9 38 9 38 9 38 9 390 390 39 0 39 0 39 0 39 8 398 39 8 39 8 383 383 38 3 38 3 38 3 38 2 38 2 38 2 38 2 38 2 39 7 397 39 7 39 7 379 37 9 379 379 379 396 39 6 39 6 39 6 39 6 39 5 395 39 5 39 5 38 1 381 38 1 38 1 38 1 38 0 380 38 0 38 0 38 0 393 39 3 39 3 39 3 394 39 4 39 4 394 39 4 3 9 2 392 39 2 39 2 3 9 2 388 388 38 8 3 8 8 38 8 36 2 362 362 362 36 1 361 3 6 0 378 378 37 8 378 378 378 377 377 377 37 7 37 7 41 9 41 9 41 9 419 41 5 41 5 4 1 5 415 415 4 1 7 417 41 7 417 4 1 7 41 6 41 6 41 6 416 41 6 41 1 411 41 1 411 3 9 9 39 9 39 9 39 9 40 6 40 6 40 6 40 6 386 386 38 6 38 6 38 6 40 1 40 1 40 1 40 1 42 2 422 42 2 4 0 0 40 0 40 0 40 0 421 4 2 1 42 1 4 2 1 421 42 1 42 0 420 420 420 4 1 8 41 8 4 1 8 41 8 41 8 40 4 404 404 40 4 4 0 3 403 403 40 3 4 1 4 414 414 414 413 41 3 4 1 3 41 3 413 41 2 41 2 41 2 412 412 41 0 41 0 410 41 0 410 4 0 9 409 40 9 409 40 8 40 8 40 8 40 8 40 5 40 5 40 5 40 5 405 40 7 40 7 40 7 40 7 40 2 402 40 2 40 2 384 384 38 4 38 4 38 4 376 376 3 7 6 376 376 371 371 37 1 371 37 1 371 366 36 6 3 6 6 366 369 36 9 36 9 36 9 369 369 387 387 38 7 38 7 38 7 368 368 36 8 368 368 36 8 36 8 367 36 7 36 7 36 7 367 367 375 375 3 7 5 375 37 5 375 374 374 37 4 37 4 37 4 373 37 3 37 3 373 3 7 3 372 3 7 2 372 37 2 3 7 2 370 37 0 37 0 37 0 3 7 0 365 36 5 36 5 36 5 36 5 365 364 36 4 36 4 364 364 363 3 6 3 36 3 363 36 3 POOL SILO HUT TEL. SHED GARAGE HOUSE HOUSE HOUSE GARAGE WATER VLV.HYD. WATER VLV.TEL. POLE C O N C R E T E HYD. RET A I N I N G W A L L CLASS III WETLANDS 20' SEWER EASEMENT SOLAR PANELS SHED GR A V E L D R I V E 50' WETLAND BUFFER 50' BUFFE R PRESUMED WETLAND (AS SHOWN ON PREVIOUS LANE PRESS PLANS) 0.24 ACRES WITHIN POSSIBLE WETLAND BUFFER N/F 835 HINESBURG RD. LLC SS SS S SS APPROX. SEPTIC SYSTEM (TYP) W W W W W W W W W W WATER SERVICE (TYP) Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM E N G I N E E R I N G S U R V E Y Field Book: For Local Permitting Only 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNIN G ENVIRON MENTAL 0 Feet Graphic Scale 40 80 120 15°± VT G r i d M a g n e t i c     Existing Conditions Plan C1-01 ----   23-015    DJG      WGM Associates 850, 900 & 950 Hinesburg Road South Burlington, Vermont 05407 EXISTING CONDITIONS NOTES: 1.THE PURPOSE OF THE EXISTING CONDITIONS PLAN IS TO DEPICT READILY APPARENT PERTINENT EXISTING CONDITIONS AS OF THE DATE OF SURVEY. 2.BEARINGS SHOWN ARE BASED UPON VERMONT GRID NORTH USING VTVRS CORS STATION. 3.VERTICAL DATUM IS BASED ON NAVD88 (GEIOD 18). A CARLSON BRx7 RTK GPS UNIT WAS EMPLOYED FOR THESE OBSERVATIONS. 4.COORDINATE SYSTEM IS BASED ON VERMONT STATE PLANE (U.S. SURVEY FEET). 5.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS SHOWN ARE BASED ON RESEARCH, UTILITY PLANS PROVIDED BY OTHERS, AND/OR SURFACE EVIDENCE ENCOUNTERED AND WERE OBTAINED IN A MANNER CONSISTENT WITH THE ORDINARY STANDARD OF PROFESSIONAL CARE AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE DESIGN ENGINEER. ADDITIONAL UTILITIES NOT SHOWN MAY EXIST. ENGINEER SHALL BE NOTIFIED IF ANY DISCREPANCIES ARE ENCOUNTERED. ACTUAL LOCATION OF UNDERGROUND UTILITIES MAY VARY. DIGSAFE MUST BE CONTACTED PRIOR TO ANY EXCAVATION. CALL 1-888-DIG SAFE (344-7233) OR CALL 811. 6.PERIMETER BOUNDARIES SHOWN HEREON FROM TAX MAP INFORMATION AND OTHER RESOURCES, AND DOES NOT DEPICT A FORMAL BOUNDARY SURVEY. PROJECT LOCATION