Loading...
HomeMy WebLinkAboutSP-23-040 - Plans - Non-Record - 1068 Williston RoadINTERSTATE 89 Willis t o n R d . D o r s e t S t . SITE White S t . P a t c h e n R d . V T 1 1 6 \\ V H B . C O M \ G B L \ P R O J \ S B U R L I N G T O N \ 5 7 9 1 3 . 0 1 L A R K I N H O L I D A Y I N N \ C A D \ L D \ P L A N S E T \ 5 7 9 1 3 . 0 1 - C O V 13 D e c e m b e r 2 0 2 3 Owner/Applicant: VH B P r o j e c t : vh b . c o m Is s u e d f o r : Champlain School Apartments Partnership 410 Shelburne Road Burlington, Vermont 05401 40 IDX Dr Building 100 Suite 200 South Burlington, VT 05403 802.497.6100 Feet0400800 Site Plans Issued for Date Issued Latest Issue Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, VT Ph 2A Local Approval July 29,2021 December 12, 2023 57 9 1 3 . 0 1 Co n s t r u c t i o n Sheet Index No.Drawing Title Latest Issue C1.00 Legend and General Notes 10/17/2022 C2.01 Proposed Site Plan 12/12/2023 C3.01 Grading and Drainage Plan 12/12/2023 C3.02 Intersection Grading Plan 5/23/2023 C4.01 Utility Plan 12/12/2023 C5.01 Roadway Profile Plan 6/8/2023 C5.02 Waterline Profiles Plan 5/23/2023 C5.03 Sewer Profile Plan 6/8/2023 C6.01 Erosion and Sediment Control Plan 12/12/2023 C7.01 Site Details 1 10/17/2022 C7.02 Site Details 2 10/17/2022 C7.03 Site Details 3 6/8/2023 C7.04 Site Details 4 8/8/2023 C8.00 EPSC Narrative and Notes 10/17/2022 C8.01 EPSC Details 10/17/2022 Reference Drawings No.Drawing Title Latest Issue Sv-1 Boundary and Topographic Survey Plat 10/18/2021 Sheet Index No.Drawing Title Latest Issue L0.00 General Notes & Abbreviations 8/14/2023 L2.00 Overall Landscape Layout & Materials 12/12/2023 L2.01 Landscape Layout and Materials Enlargement 8/14/2023 L2.02 Landscape Layout and Materials Enlargement 12/12/2023 L3.00 Landscape Details 8/14/2023 L3.01 Landscape Details 8/14/2023 L3.02 Landscape Details 8/14/2023 L3.03 Landscape Details 8/14/2023 L4.00 Overall Planting Plan 12/12/2023 L4.01 Planting Plan Enlargement 12/12/2023 L4.02 Planting Plan Enlargement 12/12/2023 L4.03 Planting Plan Enlargement 12/12/2023 L4.04 Landscape and Open Space 12/12/2023 L4.05 Open Space (Phase 2A)12/12/2023 L5.00 Planting Details 8/14/2023 L6.00 Overall Landscape Lighting Plan 12/12/2023 L6.01 Landscape Lighting Plan Enlargement 8/14/2023 L6.02 Landscape Lighting Plan Enlargement 12/12/2023 L6.03 Landscape Lighting Plan Enlargement 12/12/2023 L6.04 Landscape Lighting Plan Enlargement 12/12/2023 L6.05 Landscape Lighting Plan Enlargement 10/31/2023 of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 General Notes & Abbreviations L0.00 17 JKH MKW LAYOUT NOTES 1. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CHECK WITH WITH LANDSCAPE ARCHITECTURAL DRAWINGS BEFORE INSTALLATION OF CONSULTANT WORK. ANY WORK INSTALLED IN CONFLICT WITH ANY OF THE DRAWINGS SHALL BE CORRECTED AT NO EXPENSE OF THE OWNER OR DESIGN CONSULTANTS. 2. ALL SYMBOLS, ABBREVIATIONS AND MATERIAL INDICATIONS ARE CONSIDERED TO BE CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR EXACT MEANING, THE CONTRACTOR SHALL REQUEST THAT THE LANDSCAPE ARCHITECT ISSUE A CLARIFICATION. 3. DO NOT SCALE DRAWINGS. DIMENSIONS MISSING FROM PLANS OR NEEDED FOR EXECUTION OF THE WORK SHALL BE CLARIFIED OR PROVIDED BY THE LANDSCAPE ARCHITECT BEFORE THE WORK IS INSTALLED. a.ALL DIMENSIONS ARE TO FACE OF FINISH MATERIAL, UNLESS OTHERWISE NOTED. b.TAKE ALL DIMENSIONS PERPENDICULAR TO ANY REFERENCE LINE, WORK LINE, CENTERLINE, OR FACE OF BUILDING/STRUCTURE. c.ALL DIMENSIONS CALLED OUT AS "EQUAL" ARE CONSIDERED EQUIDISTANT MEASUREMENTS. 4. REFERENCE TO NORTH IS TRUE NORTH. 5. REFERENCE TO SCALE IS FOR FULL SIZED DRAWINGS, NOT REDUCED PLANS. DO NOT SCALE FROM DRAWINGS. 6. ANY CONFLICTS IN WHICH THE METHODS OR STANDARDS OF INSTALLATION OR MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES GOVERNING THE PROJECT, THE LAWS AND ORDINANCES SHALL TAKE PRECEDENCE. NOTIFY THE LANDSCAPE ARCHITECT OF ALL CONFLICTS. 7. THE CONTRACTOR SHALL MAKE CERTAIN THAT THE WORK OF THE NEW CONSTRUCTION WILL NOT OBSTRUCT FIRE DEPARTMENT ACCESS TO NEARBY BUILDINGS. EXITS SHALL BE MAINTAINED CLEAR OF ALL OBSTRUCTIONS. 8. THE CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS AND NOTIFY THE LANDSCAPE ARCHITECT OF ANY CONDITIONS VARYING FROM INFORMATION HEREIN PRIOR TO PROCEEDING WITH WORK. 9. TO ESTABLISH LANDSCAPE ARCHITECTURAL INTENT, EVERY ATTEMPT HAS BEEN MADE TO IDENTIFY MOST CONDITIONS PLANTING NOTES 1.ALL PROPOSED PLANTING LOCATIONS SHALL BE STAKED AS SHOWN ON THE PLANS FOR FIELD REVIEW AND APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 2.CONTRACTOR SHALL VERIFY LOCATIONS OF ALL BELOW AND ABOVE GROUND UTILITIES AND NOTIFY OWNER'S REPRESENTATIVE OF ANY CONFLICTS. 3.NO PLANT MATERIALS SHALL BE INSTALLED UNTIL ALL GRADING AND CONSTRUCTION HAS BEEN COMPLETED IN THE IMMEDIATE AREA. CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY CONFLICT. 4.A 3-INCH DEEP MULCH PER SPECIFICATION SHALL BE INSTALLED UNDER ALL TREES AND SHRUBS, AND IN ALL PLANTING BEDS, UNLESS OTHERWISE INDICATED ON THE PLANS, OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 5.ALL TREES SHALL BE BALLED AND BURLAPPED, UNLESS OTHERWISE NOTED IN THE DRAWINGS OR SPECIFICATION, OR APPROVED BY THE OWNER'S REPRESENTATIVE. 6.FINAL QUANTITY FOR EACH PLANT TYPE SHALL BE AS GRAPHICALLY SHOWN ON THE PLAN. THIS NUMBER SHALL TAKE PRECEDENCE IN ANY CASE OF DISCREPANCY BETWEEN QUANTITIES SHOWN ON THE PLANT LIST AND THE PLAN. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES BETWEEN THE NUMBER OF THE PLANTS SHOWN ON THE PLANT LIST AND PLANT LABELS PRIOR TO BIDDING. 7.ANY PROPOSED PLANT SUBSTITUTIONS MUST BE REVIEWED BY LANDSCAPE ARCHITECT AND APPROVED IN WRITING BY THE OWNER'S REPRESENTATIVE. 8.ALL PLANT MATERIALS INSTALLED SHALL MEET THE SPECIFICATIONS OF THE "AMERICAN STANDARDS FOR NURSERY STOCK" BY THE AMERICAN ASSOCIATION OF NURSERYMEN AND CONTRACT DOCUMENTS. 9.ALL PLANT MATERIALS SHALL BE GUARANTEED FOR ONE YEAR FOLLOWING THE DATE OF ACCEPTANCE. 10.AREAS DESIGNATED "LOAM AND SEED" SHALL RECEIVE MINIMUM 6" LOAM AND SPECIFIED SEED MIX. LAWNS OVER 2:1 SLOPE SHALL BE PROTECTED WITH EROSION CONTROL FABRIC. 11.ALL DISTURBED AREAS NOT OTHERWISE NOTED ON CONTRACT DOCUMENTS SHALL BE LOAM AND SEEDED OR MULCHED AS DIRECTED BY OWNER'S REPRESENTATIVE. 12.THE PLANTING PLAN IS INTENDED FOR PLANTING PURPOSES. REFER TO SITE / CIVIL DRAWINGS FOR ALL OTHER SITE CONSTRUCTION INFORMATION. 13.ALL TREE, SHRUB, AND PERENNIAL PLANTING BEDS ARE TO BE CONTINUOUS, COMPLETELY DUG OUT AND BACKFILLED WITH THE PROPER PLANTING BED BACKFILL MATERIAL TO DEPTH SPECIFIED IN DETAILS AND SOIL PREPARATIONS SPECIFICATION. 14.IF THE LANDSCAPE CONTRACTOR PROPOSED A SUBSTITUTE PLANT SPECIES, ALL SUBSTITUTES NEED TO BE APPROVED BY THE LANDSCAPE ARCHITECT AND CITY OF SOUTH BURLINGTON IN WRITING. GENERAL NOTES 1. ALL CONTRACTORS ARE REQUIRED TO CONTACT DIG SAFE, THE MUNICIPALITIES PUBLIC WORKS DEPARTMENT, AND ANY OTHER PUBLIC OR PRIVATE AGENCIES NECESSARY FOR UTILITY LOCATION PRIOR TO ANY CONSTRUCTION. 2. UNDERGROUND UTILITIES MAY EXIST THROUGHOUT THIS SITE AND MUST BE LOCATED PRIOR TO CONSTRUCTION. WHERE UNDERGROUND UTILITIES EXIST, FIELD ADJUSTMENT MUST BE APPROVED BY A REPRESENTATIVE OF THE OWNER PRIOR TO INSTALLATION. NEITHER THE OWNER NOR THE LANDSCAPE ARCHITECT ASSUMES ANY RESPONSIBILITY WHATSOEVER, IN RESPECT TO THE CONTRACTORS ACCURACY IN LOCATING THE INDICATED ELEMENTS ON THE DRAWINGS. 3. THE LANDSCAPE ARCHITECT AND CONSULTANTS DO NOT WARRANT OR GUARANTEE THE ACCURACY AND COMPLETENESS OF THE WORK PRODUCT THEREIN BEYOND A REASONABLE DILIGENCE. IF ANY MISTAKES, OMISSIONS, OR DISCREPANCIES ARE FOUND TO EXIST WITH THE WORK PRODUCT, THE LANDSCAPE ARCHITECT SHALL BE PROMPTLY NOTIFIED SO THAT THEY MAY HAVE THE OPPORTUNITY TO TAKE ANY STEPS NECESSARY TO RESOLVE THE ISSUE. FAILURE TO PROMPTLY NOTIFY THE OWNER AND THE LANDSCAPE ARCHITECT OF SUCH CONDITIONS SHALL ABSOLVE THEM FROM ANY RESPONSIBILITY FOR THE CONSEQUENCES OF SUCH FAILURE. ACTIONS TAKEN WITHOUT THE KNOWLEDGE AND CONSENT OF THE OWNER AND THE LANDSCAPE ARCHITECT, OR IN CONTRADICTION TO THE OWNER AND THE LANDSCAPE ARCHITECTS WORK PRODUCT OR RECOMMENDATIONS, SHALL BECOME THE RESPONSIBILITY NOT OF THE OWNER AND THE LANDSCAPE ARCHITECT BUT FOR THE PARTIES RESPONSIBLE FOR THE TAKING OF SUCH ACTION. 4. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE AND LANDSCAPE ARCHITECT OF ANY DISCREPANCIES AS SOON AS THEY ARE DISCOVERED AND PRIOR TO ANY ACTION BY THE CONTRACTOR. A LA-300 DETAIL SHEET FIRST FLOOR EL +10'-0" # 7'-6" DETAIL BUBBLE SECTION SYMBOL EXTERIOR ELEVATION NORTH ARROW BUILDING ELEVATION NOTATION REVISION BUBBLE NOTE: ALL DIMENSIONS ARE TO OR FROM STRUCTRUAL GRID LINES OR FACE OF FINISH MATERIAL, U.O.N. LANDSCAPE ARCHITECTURAL SYMBOLS 1530.00 SPOT ELEVATION A LA-301 A LA-301 DIMENSION xxxxxx DETAIL NAME LANDSCAPE DRAWING ABBREVIATIONS @ AT AD AREA DRAIN AL ALIGN ALT ALTERNATE ASPH ASPHALT BC BOTTOM OF CURB BLDG BUILDING BS BOTTOM OF STEP BW BOTTOM OF WALL CB CATCH BASIN CJ CONTROL JOINT CL CENTERLINE CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS CTR CENTER DIA DIAMETER DIM DIMENSION DWG DRAWING EA EACH EJ EXPANSION JOINT ELEV ELEVATION EOP EDGE OF PAVEMENT EQ EQUAL EW EACH WAY FC FLUSH CURB FF FINISH FLOOR HP HIGH POINT HT HEIGHT I.D.INSIDE DIAMETER LP LOW POINT MAX MAXIMUM MFR MANUFACTURER MIN MINIMUM NIC NOT IN CONTRACT O.C.ON CENTER O.D.OUTSIDE DIAMETER QTY QUANTITY R RADIUS REINF REINFORCED REQ REQUIRED SPECS SPECIFICATIONS SS STAINLESS STEEL STD STANDARD TD TRENCH DRAIN TC TOP OF CURB TS TOP OF STEP TW TOP OF WALL TYP TYPICAL U.O.N.UNLESS OTHERWISE NOTED VIF VERIFY IN FIELD W/WITH W/O WITHOUT WWF WELDED WIRE FABRIC TREE PROTECTION 1.EXISTING TREES TO REMAIN SHALL BE PROTECTED WITH TEMPORARY CONSTRUCTION FENCE. ERECT FENCE AT EDGE OF THE TREE DRIPLINE PRIOR TO START OF CONSTRUCTION. 2.CONTRACTOR SHALL NOT OPERATE VEHICLES, STORE OR STOCKPILE MATERIALS, OR DISPOSE OF ANY WASTE MATERIALS, WITHIN THE TREE PROTECTION AREA. 3.DAMAGE TO EXISTING TREES CAUSED BY THE CONTRACTOR SHALL BE REPAIRED BY A CERTIFIED ARBORIST AT THE CONTRACTOR'S EXPENSE. LANDSCAPE LAYOUT AND MATERIAL PLAN 2.02 MA T C H L I N E 2 . 0 2 LIMITS OF PHASE 2A LIMITS OF PHASE 2A LIMITS OF PHASE 2A DN UP UP DN UPDN Ground Floo r Second Floo r Ground Floo r Second Floo r TOTAL GSF = 59,815 SF FFE = 313.95' TOTAL GSF = 136,561 SF FFE = 313.9' FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING FUTURE PHASE LANDSCAPE LAYOUT AND MATERIAL PLAN 2.01 of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Overall Landscape Layout and Materials L2.00 18 MKW MPH Feet6030015 UPDN Ground Flo o r Second Flo o r FUTURE PHASE PROTECTIVE BOLLARD (TYP.) 2ea L3.02 C 20 ' - 0 " 5'-3" 5'- 0 " TY P . 5'-3" 10'-6" DUMPSTER ENCLOSURE D L3.02 D L3.0210 ' - 0 " 12 ' - 0 " 32'-0" 4'-0"2'- 0 " 2'-0" 2'- 0 " CL MIRROR OPPOSITE SIDE OF PLANTER, TYP. 12'-0" 4'-0"8' - 0 " PLANTER 'A' 6'- 0 " 10 ' - 0 " POINT OF BEGINNING, PAVING PATTERN ON ROOF CONCRETE PAVING, REFER TO CIVIL DOCS. 32'-0" 4'-0" 4'-0" PLANTER 'A' 8'- 0 " LIMITS OF PHASE 2A LIMITS OF PHASE 2A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Landscape Layout and Materials Enlargement L2.01 19 MKW MPH Feet201005 LIMITS OF PHASE 2A LIMITS OF PHASE 2A DN UP UP DN Ground Flo o r Second Flo o r FUTURE PHASE 14'-1" PROPERTY LINE BRICK PAVERS OVER CONC. (TYP.) 9'-0" TYP. FLUSH CURB, TYP. STONE SEAT WALL (TYP.) 3ea BENCHES (8') (TYP.) 8ea 11'-1" L3.00 B L3.02 A ALIGN L3.03 A D L3.02 PRIVACY WALL, TYP. REFER TO ARCH. DOCS. PRIVACY SCREEN, TYP. REFER TO ARCH. DOCS.PEDESTAL PAVERS, TYP. REFER TO DETAIL D2/A-501 GREEN ROOF PLANTING TRAYS, TYP. REFER TO DETAIL D3/A-501, REFER TO DETAIL D/L3.02 FOR SPEC. INFO, ETC. 12 ' - 0 " 32'-0" 4'-0"2'- 0 " 2'-0" 2'- 0 " CL MIRROR OPPOSITE SIDE OF PLANTER, TYP. 12'-0" 12 ' - 0 " 4'-0" 4'-0" 4'-0" 32'-0" 32'-0" 12 ' - 0 " 12 ' - 0 " 6'- 0 " PLANTER 'A' PLANTER 'A'6'- 0 " 6'- 0 " 10 ' - 0 " 10 ' - 0 " L3.00 D PLANTER 'A' POINT OF BEGINNING, PAVING PATTERN ON ROOF 6'-0", CENTER ON DOOR OPENING 6'- 0 " 4'-0" PLANTER 'A' 8'- 0 " 8'- 0 " 8'- 0 " 13'-0" TYP. 6' - 0 " TY P . 12 ' - 0 " 33 ' - 1 1 " 22 ' - 4 " 19 ' - 6 " TEMPORARY ASPHALT PATHWAY, REFER TO ENG. DRAWINGS LIMIT OF FLUSH CURB 20'-3" 1' - 6 " TY P . 7' - 6 " TY P . 5'-0" TRELLIS (TYP.) 4ea L3.03 B BRICK PAVERS - ADA DETECTABLE WARNING (TYP). 3ea. ALIGN WITH BUILDING COLUMN ALIGN WITH WINDOW/ BUILDING CORNER REFER TO DETAIL B/L3.00 FOR PAVING PATTERN WEEP HOLES IN CONC. BASE, TYP. OF +/-16 REFER TO DETAIL B/L3.00 WEEP HOLES IN CONC. BASE, TYP. OF +/-49 REFER TO DETAIL B/L3.00 WEEP HOLES IN CONC. BASE, TYP. OF +/-21 (+/-7 WEEPS BEHIND EACH SEAT WALL) REFER TO DETAIL B/L3.00 WEEP HOLES ARE ONLY REQUIRED ALONG THE FACE OF CURB AND STONE SEAT WALL, THEY ARE NOT REQUIRED ALONG THE LANDSCAPE BEDS LIMIT OF PROPOSED CURB IN THIS PHASE WEEP HOLES IN CONC. BASE, TYP. OF +/-3 REFER TO DETAIL B/L3.00 WEEP HOLES IN CONC. BASE, TYP. OF +/-20 (+/-10 WEEPS BETWEEN SEAT WALLS) REFER TO DETAIL B/L3.00 BENCHES (6') (TYP.) 3eaL3.00 D 9 of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Landscape Layout and Materials Enlargement L2.02 20 MKW MPH Feet201005 of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Landscape Details L3.00 21 JKH MKW BRICK PAVERS OVER CONCRETE SCALE 1" = 1'-0" COMPACTED NATIVE SUBGRADE NOTES: 1. REFER TO LAYOUT PLANS FOR PAVER LOCATIONS. 2. INSTALL PAVER EDGE RESTRAINT WHERE PAVERS ARE UNRESTRAINED AGAINST LAWN, LANDSCAPE BEDS, OR PHASING LIMIT/CONSTRUCTION AREA. REFER TO PAVER EDGE RESTRAINT DETAIL. 3. PROVIDE 1" DIA. I.D. CAST IN PLACE WITH PVC. TOP OF WEEP SHALL BE FLUSH WITH CONCRETE SLAB. DRILLED WEEPS ARE NOT ACCEPTABLE. COVER WEEPS WITH FILTER FABRIC MIRAFI 140N. FILTER FABRIC TO EXTEND 12" MIN. BEYOND WEEPS. REFER TO LANDSCAPE LAYOUT PLANS FOR LOCATIONS. 4. REFER TO SPECIFICATIONS FOR PAVER MANUFACTURER AND COLOR. 6" CONCRETE SUB-SLAB, CONCRETE SLAB SHALL HAVE A SMOOTH FLOAT FINISH 4" x 8" x 2-1/4" BRICK PAVER 1/8" SAND SWEPT JOINTS SEE LANDSCAPE PLAN L2.02 FOR PAVING PATTERN ORIENTATION BRICK PAVER (4" x 8") SOLDIER COURSE, WHERE PAVER ORIENTATION CHANGES DIRECTION, SEE LANDSCAPE PLAN L2.02 PLAN: PAVING PATTERN 8" 8"SEE PLAN BRICK PAVER (4" x 8") SOLDIER COURSE, ALL SIDES OF PAVING FIELD SE E P L A N BRICK PAVER (4" x 8") RUNNING BOND, SEE PLAN FOR PAVER ORIENTATION 4" 8"4" PLAN: PAVING PATTERN 4" 8"4" 4" 8" 4" 3/8" CLEAN CRUSHED STONE LEVELING COURSE, 1" DEPTH CRUSHED GRAVEL BASE, REFER TO ENG. DRAWINGS WEEP HOLES, REFER TO NOTES, SEE LANDSCAPE LAYOUT PLANS FOR LOCATIONS REFER TO NOTE #3 FILTER FABRIC BETWEEN CONCRETE SLAB AND SETTING BED A PAVER EDGE RESTRAINT SCALE 2" = 1'-0" PAVER EDGE RESTRAINT B.E.A.S.T PLASTIC PAVER EDGING INSTALL EDGING IN REVERSE MODE ATTACH TO CONCRETE SUB-SLAB USING S.S. SCREWS EVERY 24" MIN. BRICK OR STONE PAVER REFER TO LANDSCAPE LAYOUT PLANS LAWN \ LANDSCAPE AREA CONCRETE SUB-SLAB Notes: 1. PROVIDE SUBMITTAL SAMPLE FOR REVIEW AND APPROVAL. BBENCH SCALE N.T.S. 1" x 3-1/2" WOOD SLATS 1" x 2-1/2" WOOD SLATS 1/2" X 2" SOLID STEEL BAR FINISHED END UNIT CLEARANCE FOR 1/2" ANCHOR BOLTS SEAT HEIGHT 22-3/8" 24-7/8" 29 - 3 / 4 " 17 - 1 / 2 " VARIES, 6-8', REFER TO LAYOUT PLAN FOR LOCATIONS NOTES: 1.METAL COLOR TO BE BLACK POWDER COAT. 2.6' BENCH: VICTOR STANLEY EVA 6' BACKED BENCH WITH WOOD SLATS, SURFACE MOUNT (EVA-20-W) 3.8' BENCH: VICTOR STANLEY EVA 8' BACKED BENCH WITH WOOD SLATS, SURFACE MOUNT (EVA-20-W) 4.LOCATIONS TO BE VERIFIED BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 5.6' BENCH TO BE SURFACE MOUNTED. 6.DO NOT SURFACE MOUNT 8' BENCH WITHIN PORCELAIN PAVERS. 7.INSTALL PER MANUFACTURER'S RECOMMENDATIONS. BOLLARD - FIXED SCALE N.T.S. NOTES: 1. REFER TO LAYOUT PLANS FOR BOLLARD LOCATIONS. 2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. PLAN AXONOMETRIC SIDEWALK/PLAZA ROADWAY 5' - 0 " M I N . MM CITE SI105 ISAC ALUMINUM BOLLARD ADJACENT PAVING, SEE PLANS FOR MATERIALS AND FINISH GRADE CONCRETE FOUNDATION CL 1'-0" VARIES, 1'-0" TYP., SEE PLAN FLUSH CURB ADJACENT PAVING, SEE PLAN SECTION: BOLLARD AT FLUSH CURB SIDEWALK/PLAZA ROADWAY 5' - 0 " M I N . MM CITE SI105 ISAC ALUMINUM BOLLARD ADJACENT PAVING, SEE PLANS FOR MATERIALS AND FINISH GRADE CONCRETE FOUNDATION CL 1'-0" 1'-6" TYP.FLUSH CURB ADJACENT PAVING, SEE PLAN SECTION: BOLLARD AT RAISED CURB C D N. I . C . of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Landscape Details L3.01 22 JKH MKW BIKE RACK SCALE 1" = 1' LOOP BIKE RACK, REFER TO SPECIFICATIONS NOTES: 1. COLOR TO BE BLACK POWDER COAT. 2. LOCATIONS TO BE VERIFIED BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 3. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 3' - 0 " T Y P . SP A C I N G B E T W E E N R A C K S PLAN ELEVATION 2' - 0 " EQ. CONCRETE PAD, REFER TO LAYOUT DRAWINGS 1'-8" SECTION 7'-0" CL BIKE RACK EQ. IN-GROUND MOUNT CORE DRILLED AND SET W/ EPOXY GROUT B CHARGING STATION SCALE 1" = 1'-0" 6" STEEL BOLLARD W/ SMOOTH SAFETY YELLOW SLEEVE OVER THE TOP. ·INSTALL BOLLARD 48" ABOVE FINISHED GRADE. ·INSTALL BOLLARD SO BASE IS 48" BELOW FINISHED GRADE ENCASED IN AN 18" DIA. CONCRETE FOOTING. CENTER FOOTING ON PARKING STRIPE LOCATION CL 1'-0" 1' - 2 " 1' - 2 " PARKING STRIPE, TYP. 12 " 12 " CHARGING STATION MOUNTING TEMPLATE PROVIDED BY CHARGEPOINT 24" DIA. CONCRETE FOOTING CL CL 12"12" TEMPLATE LAYOUT CL 6" CHARGING STATION BASE PLATE AND ANCHOR BOLTS, INSTALL PER MANUFACTURER'S RECOMMENDATIONS ASPHALT PAVING 24" DIA. CONCRETE FOOTING, INSTALL PER MANUFACTURER'S RECOMMENDATIONS 45° CHAMFERED EDGE SECTION: CHARGING STATION FOOTING CHARGING STATION BASE ELECTRICAL CONDUIT, INSTALL PER MANUFACTURER'S RECOMMENDATIONS CL CL ASPHALT PAVING / PARKING SPACE ASPHALT PAVING / PARKING SPACE 2'-0" 24" DIA. CONCRETE FOOTING, INSTALL PER MANUFACTURER'S RECOMMENDATIONS 45° CHAMFERED EDGE CHARGING STATION CONCRETE WHEEL STOP, TYP. A 6' SCREEN FENCE SCALE 1/2" = 1'-0" ELEVATION NOTES: 1.CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL BY LANDSCAPE ARCHITECT. 2.ALL FENCE COMPONENTS TO BE BLACK 3.INSTALL PER MANUFACTURER'S RECOMMENDATIONS 6' - 0 " 2" 48" LOADING DOCK DRIVEWAY LANDSCAPE 12" CONCRETE FOOTING 4,000 PSI, 2" ABOVE FINISH GRADE W/ 45 DEGREE CHAMFERED EDGE SCREEN PANEL MANUFACTURER: LANDSCAPE FORMS PRODUCT: LINE PANEL ONE-INCH HORIZONTAL SLATS, 6 FEET TALL BASEPLATE AND S.S. ANCHOR BOLTS (INSTALL PER MANUFACTURERS SPECIFICATIONS) PANEL BOLTS TO POST PLAN SECTION 6' - 0 " C N.I.C . N.I.C . N. I . C . of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Landscape Details L3.02 23 JKH MKW B C A TRELLIS SCALE 1/2" = 1'-0" 3/8" TYP. #5104 STEEL CHANNEL TRIM WITH DRILL HOLES @ PANEL EDGES PARALLEL TO POST STAINLESS STEEL THRU-BOLT, TYP. 3" THK. greenscreen® PANEL, TYP.3" SQUARE STEEL 3/16" THICK POST STAINLESS STEEL THRU-BOLT #5136.375 SPACERS - 3/8"x1-1/2" DIA. BLACK UHMW PLASTIC, TYP. #5104 STEEL CHANNEL TRIM WITH DRILL HOLES @ PANEL EDGES PARALLEL TO POST 3" SQUARE STEEL 3/16" THICK POST #5104 CHANNEL TRIM @ TOP EDGE PANEL #5136.375 SPACERS - 3/8"x1-1/2" DIA. BLACK UHMW PLASTIC, TYP. #5139 SQUARE POST CAP ELEVATION: CONCEALED FASTENER - POST MOUNTED PLAN/SECTION: FASTENER N.T.S. N.T.S. 8' - 6 " , T Y P . 4' - 0 " P A N E L H E I G H T 4' - 0 " P A N E L H E I G H T ELEVATION: FREESTANDING HORIZONTAL TRELLIS PLAN 7'-8", TYP. 7'-4", TYP. CENTER TRELLIS ON BUILDING COLONNADE, TYP. BUILDING FACE 18" CONCRETE FOOTING 4,000 PSI, 2" ABOVE FINISH GRADE w/ 45 DEGREE CHAMFERED EDGE 3" THK. greenscreen® PANEL, TYP. 3" SQUARE STEEL POST w/ POST CAP, TYP. #5104 CHANNEL TRIM @ TOP EDGE OF PANEL, TYP. STAINLESS STEEL THRU-BOLT, TYP. SEE ENLARGEMENT 3" THK. greenscreen® PANEL, TYP. #5105 STEEL EDGE TRIM @ BOTTOM EDGE OF PANEL FINISH GRADE #5131 FLEX "C" RINGS @ PANEL TO PANEL SEAM @ 12" O.C. 3" SQUARE STEEL POST w/ POST CAP, TYP. SEE ENLARGEMENT FOR ATTACHMENT BUILDING COLONNADE BEYOND TRELLIS AND POSTS TO FIT WITHIN COLONNADE WIDTH, TYP. 6" 5' - 0 " 2' - 0 " 18" 8" TY P . BRICK PAVERS OVER CONCRETE (VEHICULAR) SCALE 1" = 1'-0" COMPACTED NATIVE SUBGRADE NOTES: 1. REFER TO LANDSCAPE LAYOUT AND MATERIAL PLANS FOR PAVER LOCATIONS. 2. REFER TO SPECIFICATIONS FOR PAVER INFORMATION. REINFORCED CONCRETE SUB-SLAB TACK COAT OF 2% NEOPRENE MODIFIED ASPHALT ADHESIVE CRUSHED GRAVEL BASE, REFER TO CIVIL DRAWINGS 4" x 8" x 2-3/4" BRICK PAVER 1/8" SAND SWEPT JOINTS FLUSH CURB, REFER TO LANDSCAPE LAYOUT AND MATERIAL PLANS FOR LOCATIONS ASPHALT PAVING, REFER TO CIVIL DRAWINGS PLAN: PAVING PATTERN N.T.S. BRICK PAVER (4" x 8") HERRINGBONE PATTERN, REFER TO LANDSCAPE MATERIALS PLAN FOR PAVER ORIENTATION PAVING PATTERN TO BE SQUARE WITH ADJACENT CURB WHERE APPLICABLE, REFER TO LANDSCAPE MATERIALS PLAN FOR PAVER ORIENTATION ADJACENT PAVING, SEE PLAN ASPHALT PAVING, REFER TO ENG. DRAWINGS FLUSH CURB, REFER TO LANDSCAPE LAY MATERIALS PLAN FOR LOC STANDARD CURB, REFER TO CIVIL DRAWINGS 8" 4" CO N C R E T E S I D E W A L K , BA S E A N D S U B - B A S E MA T E R I A L R E F E R T O CI V I L P L A N S SET CURB IN CLASS B CONCRETE, FULL LENGTH OF CURB 1'-0"1'-0" 6" PROTECTIVE BOLLARD SCALE N.T.S. NOTES: 1. REFER TO LAYOUT PLANS FOR BOLLARD LOCATIONS. ROUNDED CONCRETE CAP CONCRETE FILL 6" DIA. SCHEDULE 40 STEEL PIPE FILLED WITH CONCRETE. PAINT PRIME AND FINISH COATS TO BE COMPATIBLE WITH EXTERIOR METAL SURFACES. COLOR: BLACK FINISHED GRADE, SURFACE TREATMENT VARIES, SEE PLAN 24" DIA. CONCRETE ENCASEMENT COMPACTED GRAVEL COMPACTED SUBGRADE 3' - 0 " 5' - 0 " M I N . 6" PEDESTAL PAVERS AT GREEN ROOF SCALE 1" = 1'-0" LIVEROOF "DEEP" PLANTING TRAY, MODULE SIZE=1'x2' (6" SOIL DEPTH), SEE DETAIL D3/A-501 FOR ROOF DETAIL BISON IP VERSADJUST PEDESTAL SYSTEM, SEE PLAN FOR LOCATIONS, SEE DETAIL D2/A-501FOR ROOF DETAIL LIVEROOF ENGINEERED SOIL MEDIUM VA R I E S , SE E P L A N 2'-0" TYP. NOTES: 1. REFER TO LAYOUT PLANS FOR PAVER, PEDESTAL, AND PLANTING TRAY LOCATIONS. 2. INSTALL LIVEROOF "ROOFEDGE" SYSTEM PER MANUFACTURER'S RECOMMENDATIONS. 3. INSTALL PEDESTAL SYSTEM PER MANUFACTURER'S RECOMMENDATIONS. 4. REFER TO ARCHITECT'S DETAILS D2 AND D3/A-501 FOR COORDINATION WITH GREEN ROOF. CAESAR AEXTRA20 PORCELAIN ROOFTOP PAVER, 24"x24"x0.75" TILE, GRAUSTEIN FINISH, SEE PLAN FOR LOCATIONS INSTALL PERIMETER PEDESTALS PER MANUFACTURER'S RECOMMENDATIONS LIVEROOF "ROOFEDGE" ALUMINUM EDGING SYSTEM. BLACK ANODIZED FINISH. MATCH SIZE TO ADJACENT TRAY TYPE. UTILIZE FACTORY-FORMED CORNERS AND SLIDING CONNECTORS AS RECOMMENDED BY MANUFACTURER. VA R I E S PLANTING, SEE PLANTING PLAN ROOF ASSEMBLY, SEE ARCH. DRAWINGS DDECORATIVE STONE SCALE 1/2" = 1'-0" STEEL EDGING PAINTED BLACK MANUFACTURER: BORDER CONCEPTS EDGING: BORDER KING STAKES: 24" LONG CONTRACTOR TO PROVIDE SUBMITTALS FOR REVIEW AND APPROVAL 3-4" MINUS GRANITE, INSTALL FLUSH WITH SURROUNDING GRADE COLOR TO BE SELECTED BY LANDSCAPE ARCHITECT COMPACTED SUBGRADE 12 " NOTE: 1. INSTALL DECORATIVE STONE PER LAYOUT PROVIDED IN THE LANDSCAPE PLANS BUILDING FACE E N. I . C . N.I.C . DN UP UP DN UPDN Ground Floor Second Floor Ground Floo r Second Floo r FUTURE PHASE FUTURE PHASE 9 DECIDUOUS TREES QTY BOTANICAL NAME COMMON NAME SIZE AF 2 Acer x freemanii `Sienna`Sienna Glen Maple 2 1/2 - 3" CAL./ B&B BN 1 Betula nigra `Heritage`Multi-Stem Heritage River Birch 12 -14` HT. GBP 6 Ginkgo biloba `Princeton Sentry`Princeton Sentry Ginkgo 2 1/2 - 3" CAL. GT 17 Gleditsia triacanthos `Draves` TM Street Keeper Honey Locust 2 1/2 - 3" CAL. SHRUBS QTY BOTANICAL NAME COMMON NAME SIZE JP2 37 Juniperus horizontalis `Plumosa Compacta`Creeping Juniper 18 - 24" SPD MD 11 Microbiota decussata Siberian Carpet Cypress/Russian Arborvitae 18 - 24" SPD PN2 151 Physocarpus opulifolius Ninebark 18 - 24" SPD TC 5 Taxus cuspidata `Greenwave`Greenwave Yew 18 - 24" SPD PERENNIALS QTY BOTANICAL NAME COMMON NAME SIZE NF 8 Nepeta x faassenii Catmint 1 GAL. VINES QTY BOTANICAL NAME COMMON NAME SIZE PQV 8 Parthenocissus quinquefolia Virgina Creeper #1 POT GRASSES QTY BOTANICAL NAME COMMON NAME SIZE CA 111 Calamagrostis x acutiflora `Karl Foerster`Karl Foerster Feather Reed Grass 2 GAL. PVS 43 Panicum virgatum `Shenandoah`Shenendoah Switch Grass 2 GAL. PLANT SCHEDULE - Phase 2A Notes: 1.CONTRACTOR IS RESPONSIBLE TO VERIFY ALL PLANT QUANTITIES FOUND IN THE PLANTING PLANS. IF ANY DISCREPANCIES ARE FOUND, LANDSCAPE ARCHITECT SHOULD BE NOTIFIED IMMEDIATELY. 2.FINAL LAYOUT AND PLACEMENT OF ALL PLANT MATERIAL TO BE APPROVED BY THE LANDSCAPE ARCHITECT. 3.CONTRACTOR IS RESPONSIBLE TO SEED ALL DISTURBED AREAS ACCORDING TO THE SPECIFICATIONS 4.REFER TO PLANTING DETAILS FOR PROPER PLANT MATERIAL INSTALLATION REQUIREMENTS. 5.ALL TREE, SHRUB AND PERENNIAL PLANTING BEDS ARE TO BE CONTINUOUS, COMPLETELY DUG OUT AND BACKFILLED WITH THE PROPER PLANTING BED BACKFILL MATERIAL TO DEPTH SPECIFIED IN DETAILS AND SOIL PREPARATION SPECIFICATION. 6.IF THE LANDSCAPE CONTRACTOR PROPOSES A SUBSTITUTE PLANT SPECIES, ALL SUBSTITUTES NEED TO BE APPROVED BY THE LANDSCAPE ARCHITECT IN WRITING PRIOR TO ORDERING. 9 DECIDUOUS TREES QTY BOTANICAL NAME COMMON NAME SIZE ARA 4 Acer rubrum `Armstrong`Armstrong Red Maple 2 1/2 - 3" CAL. BN 4 Betula nigra `Heritage`Multi-Stem Heritage River Birch 12 -14` HT. TC2 1 Tilia cordata `Greenspire`Greenspire Littleleaf Linden 2 1/2 - 3" CAL. SHRUBS QTY BOTANICAL NAME COMMON NAME SIZE EF 51 Euonymus fortunei Wintercreeper #2 CONT. JP2 5 Juniperus horizontalis `Plumosa Compacta`Creeping Juniper 18 - 24" SPD MD 53 Microbiota decussata Siberian Carpet Cypress/Russian Arborvitae 18 - 24" SPD SB 65 Spiraea bumalda `Anthony Waterer`Anthony Waterer Spirea 18 - 24" SPD PERENNIALS QTY BOTANICAL NAME COMMON NAME SIZE HSO 38 Hemerocallis x `Stella de Oro`Stella de Oro Daylily 1 GAL. HG 10 Hosta x 'Guacamole'Guacamole Hosta 1 GAL. NF 11 Nepeta x faassenii Catmint 1 GAL. GRASSES QTY BOTANICAL NAME COMMON NAME SIZE CA 122 Calamagrostis x acutiflora `Karl Foerster`Karl Foerster Feather Reed Grass 2 GAL. PVS 47 Panicum virgatum `Shenandoah`Shenendoah Switch Grass 2 GAL. SH 33 Sporobolus heterolepis Prairie Dropseed 2 GAL. PLANT SCHEDULE - Phase 2B 9 of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Overall Planting Plan L4.00 24 JKH MKW Feet6030015 DN UP UP DN UPDN Ground Flo o r Second Flo o r Ground Flo o r Second Floo r INTERSTATE 89 FUTURE PHASE 9 GT 6 GT 1 GT 1 GT 13 PN2 13 PN2 13 PN2 13 PN2 13 PN2 13 PN2 13 PN2 13 PN2 13 PN2 13 PN2 8 PN2 13 PN2 16 JP2 1 AF 1 AF 21 JP2 REFER TO GREEN ROOF PLANTING PLAN - L4.03 REFER TO GREEN ROOF PLANTING PLAN - L4.03 11 CA 9 CA 14 PVS 31 CA 20 PVS 11 CA 9 PVS 13 CA 2 PQV 2 PQV 2 PQV 2 PQV 11 MD 8 CA 8 CA 5 TC 9 1 ARA 1 ARA 15 SH 18 SH 5 CA 22 SB10 CA 17 SB 2 ARA 6 PVS 6 PVS 37 EF 9 CA 7 EF 7 EF 1 TC2 9 CA 9 HSO 26 SB 5 JP2 8 HSO 10 HG 11 HSO41 CA 3 CA 9 CA 11 CA 11 CA 14 CA LIMITS OF PHASE 2A LIMITS OF PHASE 2A TEMPORARY OPEN SPACE LIMITS OF PHASE 2A LIMITS OF PHASE 2A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Planting Plan Enlargement L4.01 25 JKH MKW Feet4020010 DN UP UP DN Ground Flo o r Second Floo r INTERSTATE 89 WIL L I S T O N R O A D US R O U T E 2 DOR S E T S T R E E T FUTURE PHASE FUTURE PHASE 6 GBP REFER TO GREEN ROOF PLANTING PLAN - L4.03 REFER TO GREEN ROOF PLANTING PLAN - L4.03 9 CA 14 PVS 31 CA 20 PVS 11 CA 9 PVS 13 CA 2 PQV 2 PQV 2 PQV 2 PQV 11 MD 8 CA 8 CA 8 CA 5 TC 9 1 ARA 1 ARA 15 SH 18 SH 5 CA 22 SB10 CA 6 PVS 6 PVS 7 EF 7 EF 9 CA 9 HSO 5 JP2 14 CA LIMITS OF PHASE 2A LIMITS OF PHASE 2A TEMPORARY OPEN SPACE LIMITS OF PHASE 2A LIMITS OF PHASE 2A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Planting Plan Enlargement L4.02 26 JKH MKW Feet4020010 UP Ground Floor Second Floor Ground Floor Second Floor 148 GREEN ROOF 1'x2' TRAYS 148 GREEN ROOF TRAYS 72 GREEN ROOF TRAYS 148 GREEN ROOF TRAYS 148 GREEN ROOF TRAYS NOTES: 1.REFER TO DETAIL D/L3.02 FOR GREEN ROOF TRAYS 6 HSO 44 SH 3 PN3 3 PN3 6 HSO 10 SH 40 HSO 10 SH 14 NF 14 NF 8 PN3 24 CB3 32 CA 6 HSO 44 SH 3 PN3 3 PN3 6 HSO 10 SH 40 HSO 10 SH 14 NF 14 NF 8 PN3 24 CB3 6 HSO 44 SH 3 PN3 3 PN3 6 HSO 10 SH 40 HSO 10 SH 14 NF 14 NF 8 PN3 24 CB3 6 HSO 44 SH 3 PN3 3 PN3 6 HSO 10 SH 40 HSO 10 SH 14 NF 14 NF 8 PN3 24 CB3 32 CA 32 CA12 HSO 12 SA 24 RF 24 PVS 12 HSO 12 SA 24 RF 32 CA ORNAMENTAL GRASSES QTY BOTANICAL NAME COMMON NAME SIZE CA 128 Calamagrostis x acutiflora `Karl Foerster`Karl Foerster Feather Reed Grass 2 GAL. PVS 24 Panicum virgatum `Shenandoah`Shenendoah Switch Grass 2 GAL. SH 256 Sporobolus heterolepis Prairie Dropseed 2 GAL. PERENNIALS QTY BOTANICAL NAME COMMON NAME SIZE CB3 96 Chrysanthemum x superbum 'Becky'Becky Shasta Daisy 1 GAL., 18" o.c. HSO 232 Hemerocallis x `Stella de Oro`Stella de Oro Daylily 1 GAL. NF 256 Nepeta x faassenii Catmint 1 GAL., 24" o.c. PN3 56 Perovskia atriplicifolia 'Blue Jean Baby'Blue Jean Baby Russian Sage 1 GAL. RF 48 Rudbeckia fulgida `Goldsturm`Goldsturm Black-eyed Susan 1 GAL. SA 24 Sedum x 'Autumn Joy'Autumn Joy Sedum 1 GAL. PLANT SCHEDULE - GREEN ROOF Notes: 1.CONTRACTOR IS RESPONSIBLE TO VERIFY ALL PLANT QUANTITIES FOUND IN THE PLANTING PLANS. IF ANY DISCREPANCIES ARE FOUND, LANDSCAPE ARCHITECT SHOULD BE NOTIFIED IMMEDIATELY. 2.FINAL LAYOUT AND PLACEMENT OF ALL PLANT MATERIAL TO BE APPROVED BY THE LANDSCAPE ARCHITECT. 3.REFER TO DETAIL D/L3.02 FOR GREEN ROOF TRAY INSTALLATION AND COORDINATION W/ PAVER SYSTEM. 4.IF THE LANDSCAPE CONTRACTOR PROPOSES A SUBSTITUTE PLANT SPECIES, ALL SUBSTITUTES NEED TO BE APPROVED BY THE LANDSCAPE ARCHITECT IN WRITING PRIOR TO ORDERING. DN UP UP DN Ground Flo o r Second Flo o r FUTURE PHASE 1 BN 4 NF 12 CA 4 NF 9 CA 14 PVS 31 CA 20 PVS 11 CA 9 PVS 13 CA 2 PQV 2 PQV 2 PQV 2 PQV 11 MD 8 CA 8 CA 8 CA 9 1 LIMITS OF PHASE 2A LIMITS OF PHASE 2A TEMPORARY OPEN SPACE of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Planting Plan Enlargement L4.03 27 JKH MKW Feet201005 Ground Floo r Second Floo r Ground Floo r Second Floo r9 9 9 9 PARKING ISLAND 398 S.F. PARKING ISLAND 408 S.F. PARKING ISLAND 144 S.F.PARKING ISLAND 130 S.F. PARKING ISLAND 97 S.F. PARKING ISLAND 95 S.F. PARKING ISLAND 76 S.F. PARKING ISLAND 76 S.F. PARKING ISLAND 575 S.F. PARKING ISLAND 493 S.F. 10 23 23 22 12 8 3 2 16 13 13 FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING FUTURE PHASE HAMPTON INN2 EXISTING PARKING AREA NEW PARKING AREA PARKING ISLANDS OPEN SPACE OPEN SPACE, "COURTYARD", 8,867 SF, SHARED 4,440 SF RESIDENTIAL, SHADE TREES FOR PARKING REQUIREMENT of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Landscape and Open Space L4.04 28 JRD MKW Feet6030015 LANDSCAPING SUMMARY PARKING SPACES IN EXISTING PAVED AREA: 115 NEW PARKING SPACES:32 TOTAL PARKING (SURFACE PARKING):147 TOTAL PARKING LOT SHADE TREES REQUIRED (1 PER 5 SPACES)**:25 TOTAL SHADE TREES PROVIDED (In parking areas):25 * Section 13.06 (B) (2) of the LDR sets a requirement of 10% of the interior parking lot to be landscaped islands planted with trees, shrubs, and other plants. ** Section 13.06 (B) (4) of the LDR sets the requirement for parking areas to provide one (1) deciduous shade tree for every five (5) parking spaces. The required shade trees were calculated based upon the total parking spaces being provided. Total count of required trees is based on 147 total parking spaces minus the 22 parking spaces on the western parcel boundary since the Project cannot plant in the VTrans and CWD existing ROW to the west side of the parcel. NEW PARKING LOT AREA: 6,020 SF PARKING LOT INTERIOR PLANTED ISLANDS REQUIRED*: 602 SF TOTAL PARKING LOT INTERIOR PLANTED ISLANDS PROVIDED: 2,492 SF OPEN SPACE SUMMARY HOLIDAY INN GROSS SQUARE FOOTAGE: 59,814 SF MIXED-USE BUILDING I - COMMERCIAL SPACE: 5,789 SF HAMPTON INN GROSS SQUARE FOOTAGE: 83,927 SF TOTAL GROSS SQUARE FOOTAGE OF NON RESIDENTIAL* 149,530 SF * Open space requirements based open Table 8-1 Open Space Requirements, 6% of building gross floor area for non-residential buildings with a parcel size greater than 20,000 S.F for parcels in T-4 transect zone. ** Open space requirement for residential units is 60sf per residential unit. QUALIFYING OPEN SPACE REQUIRED (Non Residential*): 8,972 SF QUALIFYING OPEN SPACE REQUIRED (Residential**): 4,980 SF TOTAL OPEN SPACE REQUIRED 13,952 SF RESIDENTIAL UNITS MIXED USE BUILDING (83ea)** TOTAL OPEN SPACE PROVIDED:16,879 SF OPEN SPACE, "COURTYARD", 9,130 SF - SHARED, 4,980 SF - RESIDENTIAL, 4,150 SF - NON-RESIDENTIAL OPEN SPACE, "OUTDOOR CAFE/RESTAURANT SEATING", 3,639 SF - NON-RESIDENTIAL OPEN SPACE, "SUN TERRACE", 3,000 SF - NON-RESIDENTIAL OPEN SPACE, "SNIPPET/PARKLET", 1,110 SF - NON-RESIDENTIAL Ground Floo r Second Floo r Ground Floo r Second Floo r 10 23 23 22 12 8 3 2 16 13 13 FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING FUTURE PHASE HAMPTON INN2 OPEN SPACE of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Open Space (Phase 2A) L4.05 28A JRD MKW Feet6030015 MULTI-BUILDING OPEN SPACE SUMMARY (PHASE 2A) MIXED-USE BUILDING I - COMMERCIAL SPACE: 5,789 SF RESIDENTIAL UNITS MIXED-USE BUILDING (83ea)** * Open space requirements based open Table 8-1 Open Space Requirements, 6% of building gross floor area for non-residential buildings with a parcel size greater than 20,000 S.F for parcels in T-4 transect zone. ** Open space requirement for residential units is 60sf per residential unit. QUALIFYING OPEN SPACE REQUIRED (Non Residential*): 347 SF QUALIFYING OPEN SPACE REQUIRED (Residential**): 4,980 SF TOTAL OPEN SPACE REQUIRED 5,327 SF TOTAL OPEN SPACE PROVIDED (PHASE 2A): 7,701 SF OPEN SPACE, "COURTYARD", 5,038 SF - PUBLIC OPEN SPACE, "SUN TERRACE", 2,663 SF - PUBLIC of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Planting Details L5.00 29 JKH MKW TREE PLANTING SCALE 1/4" = 1'-0" 18"18" 1' - 0 " MI N . FINISH GRADE 2" HEMLOCK BARK MULCH REMOVE TOP HALF OF WIRE CAGE CUT AND REMOVE BURLAP FROM ROOTBALL BACKFILL MIX FOR TREE PLANTING BEDS, REFER TO SOIL PREPARATION SPECIFICATION TOP OF ROOTBALL, ROOT FLARE SHOULD BE EVIDENT. IF ROOT FLARE IS NOT EVIDENT, THEN SCRAPE OFF THE TOP LAYER OF SOIL BUILD UP ON TOP OF ROOTBALL FROM NURSERY. SOIL BELOW ROOTBALL, COMPACTED TO PREVENT SETTLING BREAK APART EDGE OF EXCAVATION W/ SHOVEL AND BLEND PLANT MIX W/ EXISTING SOIL TO PROVIDE TRANSITION TO UNDISTURBED GRADE NOTE: EXAMINE ENTIRE TREE AND REMOVE ALL NURSERY TAGS, ROPE, STRING, OR SURVEYORS TAPE TO PREVENT FUTURE GIRDLING. SURROUNDING SOIL SHOULD NOT EXCEED 80% COMPACTION, DRAINAGE WILL BE REQUIRED IF COMPACTED SOILS ARE PRESENT TEMPORARY WATERING BASIN 2 1 2" HARDWOOD STAKES. ALIGN STAKES PARALLEL W/ ROAD/ WALKS OR PARALLEL W/ DIRECTION OF PREVAILING WIND, REFER TO TREE STAKING DETAIL NYLON STRAP WITH 3/4" GROMMETS, REFER TO SPECIFICATIONS FASTEN WIRE BELOW POINT OF MAJOR BRANCHING OR TO MAJOR OUTSIDE TRUNK. 3 TIMES THE DIAMETER OF THE ROOT BALL DECIDUOUS TREE NOTE: 1. ALL TREE PLANTING BEDS ARE TO BE CONTINUOUS, COMPLETELY DUG OUT AND BACKFILLED WITH THE PROPER PLANTING BED BACKFILL MATERIAL, REFER TO SOIL PREPARATION SPECIFICATION. UNDISTURBED GRADE EXCAVATE ONLY TO SPECIFIED PLANTING DEPTH TO ENSURE STABLE BASE EVERGREEN PLANTING SCALE 1/4" = 1'-0"p-evertree.dwg TOP OF ROOTBALL TO BE PLACED AT SAME LEVEL THAT IT WAS GROWN IN NURSERY · SLIGHT ROOT FLARE SHOULD BE EVIDENT 2" BARK MULCH FINISH GRADE SURROUNDING SOIL SHOULD NOT EXCEED 80% COMPACTION, DRAINAGE WILL BE REQUIRED IF COMPACTED SOILS ARE PRESENT 12" X 1 1/2" NYLON/COTTON WEAVE TIES WITH 3/4" GROMMETS 1/8" 7 X 7 STEEL CABLE FASTENED W/ (2) ZINC PLATED CABLE CLAMPS. COVER GUYS W/3' OF 3/8" DIA. SLIP PLASTIC TUBING. TURNBUCKLE, EYE & EYE, ZINC PLATED, 10 5/8" OPEN LENGTH, 3/8" THREAD DIA. INSTALL W/ TURNBUCKLE IN OPEN POSITION. TEMPORARY WATERING BASIN (3) DUCKBILL TYPE ANCHORS BREAK APART EDGE OF EXCAVATION W/ SHOVEL AND BLEND PLANT MIX W/ EXISTING SOIL TO PROVIDE TRANSITION TO UNDISTURBED GRADE. UNDISTURBED GRADE: ESCAVATE ONLY TO SPECIFIED PLANTING DEPTH TO ENSURE STABLE BASE REMOVE TOP HALF OF WIRE CAGE CUT AND REMOVE BURLAP FROM ROOTBALL 18"18" 3 TIMES THE DIAMETER OF THE ROOT BALL REFER TO NOTE #2 BACKFILL MIX FOR TREE PLANTING BEDS, REFER TO SPECIFICATIONS 02916 SOIL PREPARATION NOTES: 1. EXAMINE ENTIRE TREE AND REMOVE ALL NURSERY TAGS, ROPE, STRING, OR SURVEYORS TAPE TO PREVENT FUTURE GIRDLING. 2. WIDTH OF TREE PIT SHALL BE 3 TIMES THE DIAMETER OF THE ROOT BALL, UNLESS TREE IS BEING PLANTED IN CONTINUOUS LANDSCAPE BEDS / PITS. .A. TREE STAKING ALONG ROAD OR WALKS B. TREE STAKING IN OPEN SPACES C. TREE GUYING DIRECTION OF PREVAILING WIND 180 180 EDGE OF WALK OR CURB EDGE OF WALK OR CURB ALIGN STAKES PARALLEL W/ ROAD OR WALKS ALIGN STAKES PARALLEL W/ DIRECTION OF PREVAILING WIND. ALL STAKES TO BE CONSISTENT. 3" CALIPER TREES OR LARGER - ALIGN 2 STAKES PARALLEL W/ ROAD OR WALKS NO SCALE TREE STAKING LAYOUT p-stake.dwg 120 120 120 AS NOTED IN PLANTING SCHEDULE. NOTE: SHRUB PLANTING SCALE: 1/2" = 1'-0" SPACING "D"ROW "A" NUMBER OF PLANTS/SQ. FT. 5' O.C. 4' O.C. 36" O.C. 30" O.C. 24" O.C. 41.52" 31.20" 26.00" 20.76" 51.96" 0.28 0.18 0.04 0.12 0.07 D A D D D A D 1'-0" MIN SEE PLAN FOR SPACING SE E S P E C S . FO R D E P T H PLANT ROW PLANT CENTER PLANT SPACING ALL EQUAL OR AS SHOWN ON PLANTING PLAN FINISH GRADE MULCH, AS SPECIFIED SHRUB ROOTBALL CONTINUOUS PLANTING PIT FILLED WITH PLANTING MIX REFER TO SOIL PREPARATION SPECIFICATIONS SUB GRADE 2. CONTINUOUS PLANTING PITS FILLED WITH PLANTING MIX PER THE DEPTH AS NOTED IN THE SPECIFICATIONS IS REQUIRED. 1. QUANTITY OF SHRUBS AND SPACING SEE PLANTING LIST FOR PLANT SPACING PERENNIAL PLANTING SCALE: 1/2" = 1'-0" 2" PLANT SPACING PLANT CENTER PLANT ROW SET AT ORIGINAL PLANTING DEPTH FINISH GRADE MULCH AS SPECIFIED SUB GRADE SEE PLANTING PLAN FOR SPACING AND QUANTITIES CONTINUOUS PLANTING PIT FILLED WITH PLANTING MIX REFER TO SOIL PREPARATION SPECIFICATIONS COMPACTED SUBGRADE 6" TOPSOIL REFER TO SPECIFICATIONS LAWN SCALE 1" = 1'-0" LAWN, REFER TO SPECIFICATIONS FOR SEEDING OR SODDING INFORMATION A B C D E F WI L L I S T O N R O A D (N O T E 9 ) (NOTE 10) DN UP UP DN UPDN Ground Floo r Second Floo r Ground Floo r Second Floo r TOTAL GSF = 59,815 SF FFE = 313.95' TOTAL GSF = 136,561 SF FFE = 313.9' 1 1 FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING 9 9 C6 C7 A1 A2 A3 A4A5 A6 A8 A9 A10 B3 C2 A7 F1 F2 F3F4 F5 F8 F9 G1 G2 G3 G4 G5 G6 C1 C3 C4C5 H3 H4 H7 H8 H9 H10 H5 H6 F7 H1 H2 F6B2 1 1 LIGHTING PLAN 6.01 LIGHTING PLAN 6.02 LIGHTING PLAN 6.03 TOTAL GSF = 59,815 SF FFE = 313.95' TOTAL GSF = 136,561 SF FFE = 313.9' FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING FUTURE PHASE LIMITS OF PHASE 2A LIMITS OF PHASE 2A LIMITS OF PHASE 2A LIGHTING PLAN 6.04 LIGHTING PLAN 6.05 of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Overall Landscape Lighting Plan L6.00 30 JKH MKW Feet6030015 LIGHT FIXTURE AND POLE SPECIFICATIONS 3,000K SACL - Saturn Cutoff LED Mounting: Manufacturer: Fixture A Pole: Fixture: Light Engine: Color Temperature: Selux 1 Optics:R3 5G700 Pole Height:20' Phillips APR5S-20 SV (Silver)Finish: DS (No uplight finish)Options: 3,000K SACL - Saturn Cutoff LED Mounting: Manufacturer: Fixture B Pole: Fixture: Light Engine: Color Temperature: Selux 1 Optics:R3 5G700 Pole Height:13' Philips APR4F-13 SV (Silver)Finish: DS (No uplight finish)Options: 3,000K7 - 70CRI Ouro20 Mounting: Manufacturer: Fixture C Pole: Fixture: Light Engine: Color Temperature: KIM Lighting FM44 (Flush Mount) Optics:Type III 24L-65 7,000 Pole Height:16' LTRA16-6188 BL (Black)Finish: SF, CLROptions: 3,000K EDGE EV3D Mounting: Manufacturer: Fixture D Fixture: Light Engine: Color Temperature: Pinnacle Recessed Shielding: Satine Lens 17.1 Watt Voltage:120-277V WhiteFinish: Voltage:120-277V Voltage:120-277V Voltage:120-277V (Approx 12foot Mounting) 3,000K 1649SK-LED Manufacturer: Fixture E Fixture: Light Source: Color Temperature: Hinkley Lighting 11W LED Mounting Height:6' (To bottom of fixture) Black SatinFinish: 3,000K SACL - Saturn Cutoff LED Mounting: Manufacturer: Fixture F Fixture: Light Engine: Color Temperature: Selux Wall Mounted, 9'-4", Optics:R4 5G400 SV (Silver)Finish: DS (No uplight finish)Options: Voltage:120-277V Fixture G Height Measured to Center of Mounting Bracket 3,000K SACL - Saturn Cutoff LED Mounting: Manufacturer: Pole: Fixture: Light Engine: Color Temperature: Selux 1 Optics:R4 - House Side Shield 5G700 Pole Height:20' Phillips APR5S-20 SV (Silver)Finish: DS (No uplight finish)Options: Voltage:120-277V Mini Beacon Pathlight Stem Length: Manufacturer: Fixture H Fixture: Teka Illumination 18" Material:Aluminum Solid State (MBP) Style:8" Shade (SD8) LED Type:7W LED, 2700K (e93) Black Satin Powercoat (BLP)Finish: Cone Cap (CC1)Cap Stype: PMC mounting plateMounting: Notes: 1.Fixture "H" shall be powered by a remote transformer, contractor to coordinate power feed and connection from mechanical room of the building. Install per manufacturer's recommendations. 2.Controls for Fixture H: Provide astrological time clock. Install dimmer connected to astrological time clock that is suitable for low temperature and high humidity use. Astrological time clock and dimmer shall be installed in a surface mounted in-use gasketed and lockable enclosure. 3.Mounting for Fixture H: Light fixture will be mounted to the deck surface using the provided mounting plate by the manufacturer. Contractor to coordinate waterproofing penetrations associated with the installation. UPDN A9 A10 G1 G2 G3 G4 G5 G6 F7 PARKING LIGHTING POWER FEED FROM BUILDING 1.5" WIRED CONDUIT WITH AC POWER LIGHT FIXTURE L7.00 A LIGHT FIXTURE L7.00 A SITE LIGHTING POWER FEED FROM BUILDING MECHANICAL ROOM 1.5" WIRED CONDUIT 1.5" WIRED CONDUIT of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Landscape Lighting Plan Enlargement L6.01 31 JKH MKW Feet201005 CONSTRUCTED 6" DI WATER SERVICE. Ground Flo o r Second Flo o r 1 FUTURE PHASE 9 9 A2 A3 A6 A8 A9 A10 B3 A7 G6 H3 H4 H7 H8 H9 H5 H6 SITE LIGHTING POWER FEED FROM BUILDING MECHANICAL ROOM 1.5" WIRED CONDUIT 1.5" WIRED CONDUIT 1.5" WIRED CONDUIT WITH AC POWER 1.5" WIRED CONDUIT WITH AC POWER LIGHT FIXTURE L7.00 A CHARGING STATION (TYP. OF 3)L3.01 ALIGHT FIXTURE L7.00 A 2" CONDUIT, PROVIDE WIRE AND CONNECT TO CHARGING STATIONS, INSTALL PER MANUFACTURER'S RECOMMENDATIONS SITE LIGHTING POWER FEED FROM BUILDING MECHANICAL ROOM H1 H2 LIGHT FIXTURE L7.00 A B2 FUTURE PHASE of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Feet201005 Landscape Lighting Plan Enlargement L6.02 32 JKH MKW DN UP UP DN Ground Flo o r Second Flo o r 1 FUTURE PHASE 9 C6 F1 F2 F3F4 F5 F8 F9 C5 H3 H4 H7 H8 H9 H10 H5 H6 SITE LIGHTING POWER FEED FROM BUILDING MECHANICAL ROOM F6 LIGHT FIXTURE A LIGHT FIXTURE L7.00 A B2 FUTURE PHASE LIMITS OF PHASE 2A LIMITS OF PHASE 2A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Feet201005 Landscape Lighting Plan Enlargement L6.03 33 JKH MKW EXISTING 8x8 TEE 8" GATE VALVE CONSTRUCTED 6" DI WATER SERVICE. 6" GATE VALVE 8"x6" REDUCER DN UP Ground Flo o r Second Flo o r 1 FUTURE PHASE 9 C6 C7 A1 A2 A4A5 A6 F2 F3F4 F5 F8 F9 C5 H4 H7 H8 H9 H10 H5 H6 CAR CHARGING STATION POWER FEED FROM BUILDING MECHANICAL ROOM 1.5" WIRED CONDUIT 1.5" WIRED CONDUIT 1.5" WIRED CONDUIT L3.01 A LIGHT FIXTURE L7.00 A 2" CONDUIT, PROVIDE WIRE AND CONNECT TO CHARGING STATIONS, INSTALL PER MANUFACTURER'S RECOMMENDATIONS 1.5" WIRED CONDUIT CENTER LIGHT POLE BASE ON PARKING STRIPE CENTER LIGHT POLE BASE ON F6 LIGHT FIXTURE L7.00 A LIGHT FIXTURE L7.00 A B2 FUTURE PHASE FUTURE PHASE LIMITS OF PHASE 2A LIMITS OF PHASE 2A LIMITS OF PHASE 2A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Address P&Z Comments 10/31/20238 Address P&Z Comments 12/12/20239 Feet201005 Landscape Lighting Plan Enlargement L6.04 34 JKH MKW WI L L I S T O N R O A D C2 F2 C1 C3 C4C5 WEATHERPROOF PULL BOX 1.5" WIRED CONDUIT 1.5" WIRED CONDUIT 1.5" WIRED CONDUIT HAND HOLE TERMINATION, FUTURE ELECTRICAL CONNECTION TO BE COORDINATED WITH SOUTH BURLINGTON DPW 1.5" WIRED CONDUIT LIGHT FIXTURE L7.00 A CENTER LIGHT POLE BASE ON FUTURE PHASE LIMITS OF PHASE 2A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval Not for Construction July 29, 2021 35 57913.01 ASI #1 02/02/20231 Revised Phase 2A Limits 06/08/20234 Paver Coordination, Silva Cell Removal 08/14/20235 Feet201005 Landscape Lighting Plan Enlargement L6.05 35 JKH MKW Revert to previously approved future hotel layout 10/31/20238 WI L L I S T O N R O A D (N O T E 9 ) INTERSTATE 89 (NOTE 10) DO R S E T ST R E E T - U S 2 General Notes Plan References Boundary and Topographic Survey Plat Sv-1 1 JFV RRC of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. Date Holiday Inn - Larkin US 2 - Williston Rd. South Burlington, VT FINAL DRAFT Oct. 18, 2021 1 57913.01 Legend vh b . c o m 40 IDX Dr Building 100 Suite 200 South Burlington, VT 05403 802.497.6100 JFV12/3/2018Added additional utility information1 JFV4/23/2019 Added easements appurtenant to subject parcel over 2 parcel 1810-01076 (bk.69 pg.128, map ref. 7) JFV1/22/2020 Water line location shown west of subj. parcel updated 3 based on recent demarcation by CWD THIS SURVEY IS BASED ON PHYSICAL EVIDENCE MEASURED IN THE FIELD, AND WRITTEN EVIDENCE ABSTRACTED FROM PUBLIC AND PRIVATE LAND RECORDS. THIS SURVEY IS CONSISTENT WITH THAT EVIDENCE. THIS PLAT WAS PREPARED IN ACCORDANCE TO THE LATEST ADOPTED VERSION OF 26 V.S.A. SECTION 2596(A) AND 27 V.S.A. SECTION 1403. RYAN CLOUTIER, VERMONT LICENSED LAND SURVEYOR #744 DATE SIAMESE CONNECTION ACCESSIBLE CURB RAMP ACCESSIBLE PARKING VAN-ACCESSIBLE PARKING COMPACT PARKING STALLS DOUBLE YELLOW LINE STOP LINE CROSSWALK PARKING COUNT MAJOR CONTOUR MINOR CONTOUR STREAM / POND / WATER COURSE SILT FENCE DETENTION BASIN RETAINING WALL STOCKADE FENCE STONE WALL FENCE TREE LINE WIRE FENCE PATH WOOD GUARDRAIL STEEL GUARDRAIL GUY WIRE & ANCHOR MATCHLINE GUY POLE HAND HOLE PULL BOX ELECTRIC MANHOLE POST INDICATOR VALVE TRANSFORMER PAD TELEPHONE MANHOLE UTILITY POLE LIGHT POLE ELECTRIC METER GAS GATE GAS METER FIRE HYDRANT WATER METER BUILDING ENTRANCE BOLLARD DOUBLE SIGN DUMPSTER PAD SIGN BUILDING LOADING DOCK MONOLITHIC CONCRETE CURB LIMIT OF CURB TYPE SAWCUT EDGE OF PAVEMENT BITUMINOUS CURB CONCRETE CURB WETLAND LINE WITH FLAG LIMIT OF DISTURBANCE FLOODPLAIN Exist.Prop. RIGHT-OF-WAY/PROPERTY LINE CONSTRUCTION LAYOUT TOWN LINE ZONING LINE BASELINE BUILDING SETBACK EASEMENT PROJECT LIMIT LINE PROPERTY LINE SEWER MANHOLE CONCENTRIC FLARED END SECTION CURB STOP & BOX TAPPING SLEEVE, VALVE & BOX WATER VALVE & BOX HEADWALL DRAIN MANHOLE CONCENTRIC PLUG OR CAP TRENCH DRAIN CLEANOUT CATCH BASIN CONCENTRIC MONITORING WELL ELECTRIC CABLE TV FIRE ALARM TELEPHONE GAS ROOF DRAIN SEWER OVERHEAD WIRE WATER DRAIN UNDERDRAIN CONSTRUCTION EXIT HEAVY DUTY PAVEMENT CONCRETE TOP & BOTTOM OF WALL ELEVATION TOP OF CURB ELEVATION BORING LOCATION TEST PIT LOCATION BOTTOM OF CURB ELEVATION SPOT ELEVATION Prop.Exist. RIPRAP ABAN ABANDON ACR ACCESSIBLE CURB RAMP ADJ ADJUST APPROX APPROXIMATE BIT BITUMINOUS BS BOTTOM OF SLOPE BWLL BROKEN WHITE LANE LINE CONC CONCRETE DYCL DOUBLE YELLOW CENTER LINE EL ELEVATION ELEV ELEVATION EX EXISTING FDN FOUNDATION FFE FIRST FLOOR ELEVATION GRAN GRANITE GTD GRADE TO DRAIN LA LANDSCAPE AREA LOD LIMIT OF DISTURBANCE MAX MAXIMUM MIN MINIMUM NIC NOT IN CONTRACT NTS NOT TO SCALE PERF PERFORATED PROP PROPOSED REM REMOVE RET RETAIN R&D REMOVE AND DISPOSE R&R REMOVE AND RESET SWEL SOLID WHITE EDGE LINE SWLL SOLID WHITE LANE LINE TS TOP OF SLOPE TYP TYPICAL CB CATCH BASIN CMP CORRUGATED METAL PIPE CO CLEANOUT DCB DOUBLE CATCH BASIN DMH DRAIN MANHOLE CIP CAST IRON PIPE COND CONDUIT DIP DUCTILE IRON PIPE FES FLARED END SECTION FM FORCE MAIN F&G FRAME AND GRATE F&C FRAME AND COVER GI GUTTER INLET GT GREASE TRAP HDPE HIGH DENSITY POLYETHYLENE PIPE HH HANDHOLE HW HEADWALL HYD HYDRANT INV INVERT ELEVATION I= INVERT ELEVATION LP LIGHT POLE PIV POST INDICATOR VALVE PWW PAVED WATER WAY PVC POLYVINYLCHLORIDE PIPE RCP REINFORCED CONCRETE PIPE R= RIM ELEVATION RIM= RIM ELEVATION SMH SEWER MANHOLE TSV TAPPING SLEEVE, VALVE AND BOX UG UNDERGROUND UP UTILITY POLE PARKING SETBACK SILT SOCK / STRAW WATTLE Legend Abbreviations General Utility BUILDINGS General 1.CONTRACTOR SHALL NOTIFY "DIG-SAFE" (1-888-344-7233) AT LEAST 72 HOURS BEFORE EXCAVATING. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SECURITY AND JOB SAFETY. CONSTRUCTION ACTIVITIES SHALL BE IN ACCORDANCE WITH OSHA STANDARDS AND LOCAL REQUIREMENTS. 3.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO THE START OF CONSTRUCTION. 4.ACCESSIBLE ROUTES, PARKING SPACES, RAMPS, SIDEWALKS AND WALKWAYS SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE FEDERAL AMERICANS WITH DISABILITIES ACT AND WITH STATE AND LOCAL LAWS AND REGULATIONS (WHICHEVER ARE MORE STRINGENT). 5.AREAS DISTURBED DURING CONSTRUCTION AND NOT RESTORED WITH IMPERVIOUS SURFACES (BUILDINGS, PAVEMENTS, WALKS, ETC.) SHALL RECEIVE FOUR (4) INCHES LOAM AND SEED. 6.WITHIN THE LIMITS OF THE BUILDING FOOTPRINT, THE SITE CONTRACTOR SHALL PERFORM EARTHWORK OPERATIONS REQUIRED UP TO SUBGRADE ELEVATIONS. 7.WORK WITHIN THE LOCAL RIGHTS-OF-WAY SHALL CONFORM TO LOCAL MUNICIPAL STANDARDS. WORK WITHIN STATE RIGHTS-OF-WAY SHALL CONFORM TO THE LATEST EDITION OF THE STATE HIGHWAY DEPARTMENTS STANDARD SPECIFICATIONS FOR HIGHWAYS AND BRIDGES. 8.UPON AWARD OF CONTRACT, CONTRACTOR SHALL MAKE NECESSARY CONSTRUCTION NOTIFICATIONS AND APPLY FOR AND OBTAIN NECESSARY PERMITS, PAY FEES, AND POST BONDS ASSOCIATED WITH THE WORK INDICATED ON THE DRAWINGS, IN THE SPECIFICATIONS, AND IN THE CONTRACT DOCUMENTS. DO NOT CLOSE OR OBSTRUCT ROADWAYS, SIDEWALKS, AND FIRE HYDRANTS, WITHOUT APPROPRIATE PERMITS. 9.TRAFFIC SIGNAGE AND PAVEMENT MARKINGS SHALL CONFORM TO THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. 10.AREAS OUTSIDE THE LIMITS OF PROPOSED WORK DISTURBED BY THE CONTRACTOR'S OPERATIONS SHALL BE RESTORED BY THE CONTRACTOR TO THEIR ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE. 11.IN THE EVENT THAT SUSPECTED CONTAMINATED SOIL, GROUNDWATER, AND OTHER MEDIA ARE ENCOUNTERED DURING EXCAVATION AND CONSTRUCTION ACTIVITIES BASED ON VISUAL, OLFACTORY, OR OTHER EVIDENCE, THE CONTRACTOR SHALL STOP WORK IN THE VICINITY OF THE SUSPECT MATERIAL TO AVOID FURTHER SPREADING OF THE MATERIAL, AND SHALL NOTIFY THE OWNER IMMEDIATELY SO THAT THE APPROPRIATE TESTING AND SUBSEQUENT ACTION CAN BE TAKEN. 12.CONTRACTOR SHALL PREVENT DUST, SEDIMENT, AND DEBRIS FROM EXITING THE SITE AND SHALL BE RESPONSIBLE FOR CLEANUP, REPAIRS AND CORRECTIVE ACTION IF SUCH OCCURS. 13.DAMAGE RESULTING FROM CONSTRUCTION LOADS SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO OWNER. 14.CONTRACTOR SHALL CONTROL STORMWATER RUNOFF DURING CONSTRUCTION TO PREVENT ADVERSE IMPACTS TO OFF SITE AREAS, AND SHALL BE RESPONSIBLE TO REPAIR RESULTING DAMAGES, IF ANY, AT NO COST TO OWNER. 15.THIS PROJECT DISTURBS MORE THAN ONE ACRE OF LAND AND FALLS WITHIN THE VT DEC CONSTRUCTION GENERAL PERMIT (CGP) PROGRAM. Utilities 1.THE LOCATIONS, SIZES, AND TYPES OF EXISTING UTILITIES ARE SHOWN AS AN APPROXIMATE REPRESENTATION ONLY. THE OWNER OR ITS REPRESENTATIVE(S) HAVE NOT INDEPENDENTLY VERIFIED THIS INFORMATION AS SHOWN ON THE PLANS. THE UTILITY INFORMATION SHOWN DOES NOT GUARANTEE THE ACTUAL EXISTENCE, SERVICEABILITY, OR OTHER DATA CONCERNING THE UTILITIES, NOR DOES IT GUARANTEE AGAINST THE POSSIBILITY THAT ADDITIONAL UTILITIES MAY BE PRESENT THAT ARE NOT SHOWN ON THE PLANS. PRIOR TO ORDERING MATERIALS AND BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL VERIFY AND DETERMINE THE EXACT LOCATIONS, SIZES, AND ELEVATIONS OF THE POINTS OF CONNECTIONS TO EXISTING UTILITIES AND, SHALL CONFIRM THAT THERE ARE NO INTERFERENCES WITH EXISTING UTILITIES AND THE PROPOSED UTILITY ROUTES, INCLUDING ROUTES WITHIN THE PUBLIC RIGHTS OF WAY. 2.WHERE AN EXISTING UTILITY IS FOUND TO CONFLICT WITH THE PROPOSED WORK, OR EXISTING CONDITIONS DIFFER FROM THOSE SHOWN SUCH THAT THE WORK CANNOT BE COMPLETED AS INTENDED, THE LOCATION, ELEVATION, AND SIZE OF THE UTILITY SHALL BE ACCURATELY DETERMINED WITHOUT DELAY BY THE CONTRACTOR, AND THE INFORMATION FURNISHED IN WRITING TO THE OWNER'S REPRESENTATIVE FOR THE RESOLUTION OF THE CONFLICT AND CONTRACTOR'S FAILURE TO NOTIFY PRIOR TO PERFORMING ADDITIONAL WORK RELEASES OWNER FROM OBLIGATIONS FOR ADDITIONAL PAYMENTS WHICH OTHERWISE MAY BE WARRANTED TO RESOLVE THE CONFLICT. 3.SET CATCH BASIN RIMS, AND INVERTS OF SEWERS, DRAINS, AND DITCHES IN ACCORDANCE WITH ELEVATIONS ON THE GRADING AND UTILITY PLANS. 4.RIM ELEVATIONS FOR DRAIN AND SEWER MANHOLES, WATER VALVE COVERS, GAS GATES, ELECTRIC AND TELEPHONE PULL BOXES, AND MANHOLES, AND OTHER SUCH ITEMS, ARE APPROXIMATE AND SHALL BE SET/RESET AS FOLLOWS: A.PAVEMENTS AND CONCRETE SURFACES: FLUSH B.ALL SURFACES ALONG ACCESSIBLE ROUTES: FLUSH C.LANDSCAPE, LOAM AND SEED, AND OTHER EARTH SURFACE AREAS: ONE INCH ABOVE SURROUNDING AREA AND TAPER EARTH TO THE RIM ELEVATION. 5.THE LOCATION, SIZE, DEPTH, AND SPECIFICATIONS FOR CONSTRUCTION OF PROPOSED PRIVATE UTILITY SERVICES SHALL BE INSTALLED ACCORDING TO THE REQUIREMENTS PROVIDED BY, AND APPROVED BY, THE RESPECTIVE UTILITY COMPANY (GAS, TELEPHONE, ELECTRIC, FIRE ALARM, ETC.). FINAL DESIGN LOADS AND LOCATIONS TO BE COORDINATED WITH OWNER AND ARCHITECT. 6.CONTRACTOR SHALL MAKE ARRANGEMENTS FOR AND SHALL BE RESPONSIBLE FOR PAYING FEES FOR POLE RELOCATION AND FOR THE ALTERATION AND ADJUSTMENT OF GAS, ELECTRIC, TELEPHONE, FIRE ALARM, AND ANY OTHER PRIVATE UTILITIES, WHETHER WORK IS PERFORMED BY CONTRACTOR OR BY THE UTILITIES COMPANY. 7.UTILITY PIPE MATERIALS SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED ON THE PLAN: A.WATER PIPES SHALL BE CLASS 52 DUCTILE IRON AND SHALL BE ENCASED IN V-BIO POLY WRAP, PER CWD SPECIFICATIONS. B.SANITARY SEWER PIPES AND ROOF DRAIN PIPES SHALL BE SDR-35 POLYVINYL CHLORIDE (PVC) SEWER PIPE C.STORM DRAINAGE PIPES SHALL BE CORRUGATED HDPE D. PIPE INSTALLATION AND MATERIALS SHALL COMPLY WITH THE STATE PLUMBING CODE WHERE APPLICABLE. CONTRACTOR SHALL COORDINATE WITH LOCAL PLUMBING INSPECTOR PRIOR TO BEGINNING WORK. 8.CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR AND SHALL FURNISH EXCAVATION, INSTALLATION, AND BACKFILL OF ELECTRICAL FURNISHED SITEWORK RELATED ITEMS SUCH AS PULL BOXES, CONDUITS, DUCT BANKS, LIGHT POLE BASES, AND CONCRETE PADS. SITE CONTRACTOR SHALL FURNISH CONCRETE ENCASEMENT OF DUCT BANKS IF REQUIRED BY THE UTILITY COMPANY AND AS INDICATED ON THE ELECTRICAL DRAWINGS. 9.CONTRACTOR SHALL EXCAVATE AND BACKFILL TRENCHES FOR GAS IN ACCORDANCE WITH GAS COMPANY'S REQUIREMENTS. 10.ALL DRAINAGE AND SANITARY STRUCTURE INTERIOR DIAMETERS (4' MIN.) SHALL BE DETERMINED BY THE MANUFACTURER BASED ON THE PIPE CONFIGURATIONS SHOWN ON THESE PLANS AND LOCAL MUNICIPAL STANDARDS. FOR MANHOLES THAT ARE 20 FEET IN DEPTH AND GREATER, THE MINIMUM DIAMETER SHALL BE 5 FEET. 11.ALL WATER LINES AND APPURTENANCES SHALL BE INSTALLED IN ACCORDANCE WITH THE CHAMPLAIN WATER DISTRIC SPECIFICATIONS AND DETAILS FOR THE INSTALLATION OF WATER LINES AND APPURTENANCES, CURRENT EDITION, HENCEFORTH THE CWD SPECIFICATIONS. Layout and Materials 1.DIMENSIONS ARE FROM THE FACE OF CURB, FACE OF BUILDING, FACE OF WALL, AND CENTER LINE OF PAVEMENT MARKINGS, UNLESS OTHERWISE NOTED. 2.CURBING SHALL BE CAST IN PLACE CONCRETE WITHIN THE SITE UNLESS OTHERWISE INDICATED ON THE PLANS. 3.SEE ARCHITECTURAL DRAWINGS FOR EXACT BUILDING DIMENSIONS AND DETAILS CONTIGUOUS TO THE BUILDING, INCLUDING SIDEWALKS, RAMPS, BUILDING ENTRANCES, STAIRWAYS, UTILITY PENETRATIONS, CONCRETE DOOR PADS, COMPACTOR PAD, LOADING DOCKS, BOLLARDS, ETC. 4.PROPOSED BOUNDS AND ANY EXISTING PROPERTY LINE MONUMENTATION DISTURBED DURING CONSTRUCTION SHALL BE SET OR RESET BY A PROFESSIONAL LICENSED SURVEYOR. 5.PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY EXISTING PAVEMENT ELEVATIONS AT INTERFACE WITH PROPOSED PAVEMENTS, AND EXISTING GROUND ELEVATIONS ADJACENT TO DRAINAGE OUTLETS TO ASSURE PROPER TRANSITIONS BETWEEN EXISTING AND PROPOSED FACILITIES. Demolition 1.CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING MANMADE SURFACE FEATURES WITHIN THE LIMIT OF WORK INCLUDING BUILDINGS, STRUCTURES, PAVEMENTS, SLABS, CURBING, FENCES, UTILITY POLES, SIGNS, ETC. UNLESS INDICATED OTHERWISE ON THE DRAWINGS. REMOVE AND DISPOSE OF EXISTING UTILITIES, FOUNDATIONS AND UNSUITABLE MATERIAL BENEATH AND FOR A DISTANCE OF 10 FEET BEYOND THE PROPOSED BUILDING FOOTPRINT INCLUDING EXTERIOR COLUMNS. 2.EXISTING UTILITIES SHALL BE TERMINATED, UNLESS OTHERWISE NOTED, IN CONFORMANCE WITH LOCAL, STATE AND INDIVIDUAL UTILITY COMPANY STANDARD SPECIFICATIONS AND DETAILS. THE CONTRACTOR SHALL COORDINATE UTILITY SERVICE DISCONNECTS WITH THE UTILITY REPRESENTATIVES. 3.CONTRACTOR SHALL DISPOSE OF DEMOLITION DEBRIS IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS, ORDINANCES AND STATUTES. 4 THE DEMOLITION LIMITS DEPICTED IN THE PLANS IS INTENDED TO AID THE CONTRACTOR DURING THE BIDDING AND CONSTRUCTION PROCESS AND IS NOT INTENDED TO DEPICT EACH AND EVERY ELEMENT OF DEMOLITION. THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING THE DETAILED SCOPE OF DEMOLITION BEFORE SUBMITTING ITS BID/PROPOSAL TO PERFORM THE WORK AND SHALL MAKE NO CLAIMS AND SEEK NO ADDITIONAL COMPENSATION FOR CHANGED CONDITIONS OR UNFORESEEN OR LATENT SITE CONDITIONS RELATED TO ANY CONDITIONS DISCOVERED DURING EXECUTION OF THE WORK. 5.UNLESS OTHERWISE SPECIFICALLY PROVIDED ON THE PLANS OR IN THE SPECIFICATIONS, THE ENGINEER HAS NOT PREPARED DESIGNS FOR AND SHALL HAVE NO RESPONSIBILITY FOR THE PRESENCE, DISCOVERY, REMOVAL, ABATEMENT OR DISPOSAL OF HAZARDOUS MATERIALS, TOXIC WASTES OR POLLUTANTS AT THE PROJECT SITE. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY CLAIMS OF LOSS, DAMAGE, EXPENSE, DELAY, INJURY OR DEATH ARISING FROM THE PRESENCE OF HAZARDOUS MATERIAL AND CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE ENGINEER FROM ANY CLAIMS MADE IN CONNECTION THEREWITH. MOREOVER, THE ENGINEER SHALL HAVE NO ADMINISTRATIVE OBLIGATIONS OF ANY TYPE WITH REGARD TO ANY CONTRACTOR AMENDMENT INVOLVING THE ISSUES OF PRESENCE, DISCOVERY, REMOVAL, ABATEMENT OR DISPOSAL OF ASBESTOS OR OTHER HAZARDOUS MATERIALS. Erosion Control 1.PRIOR TO STARTING ANY OTHER WORK ON THE SITE, THE CONTRACTOR SHALL NOTIFY APPROPRIATE AGENCIES AND SHALL INSTALL EROSION CONTROL MEASURES AS SHOWN ON THE PLANS AND AS IDENTIFIED IN FEDERAL, STATE, AND LOCAL APPROVAL DOCUMENTS PERTAINING TO THIS PROJECT. 2.CONTRACTOR SHALL INSPECT AND MAINTAIN EROSION CONTROL MEASURES ON A WEEKLY BASIS (MINIMUM) OR AS REQUIRED PER THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP). THE CONTRACTOR SHALL ADDRESS DEFICIENCIES AND MAINTENANCE ITEMS WITHIN TWENTY-FOUR HOURS OF INSPECTION. CONTRACTOR SHALL PROPERLY DISPOSE OF SEDIMENT SUCH THAT IT DOES NOT ENCUMBER OTHER DRAINAGE STRUCTURES AND PROTECTED AREAS. 3.CONTRACTOR SHALL BE FULLY RESPONSIBLE TO CONTROL CONSTRUCTION SUCH THAT SEDIMENTATION SHALL NOT AFFECT REGULATORY PROTECTED AREAS, WHETHER SUCH SEDIMENTATION IS CAUSED BY WATER, WIND, OR DIRECT DEPOSIT. 4.CONTRACTOR SHALL PERFORM CONSTRUCTION SEQUENCING SUCH THAT EARTH MATERIALS ARE EXPOSED FOR A MINIMUM OF TIME BEFORE THEY ARE COVERED, SEEDED, OR OTHERWISE STABILIZED TO PREVENT EROSION. 5.UPON COMPLETION OF CONSTRUCTION AND ESTABLISHMENT OF PERMANENT GROUND COVER, CONTRACTOR SHALL REMOVE AND DISPOSE OF EROSION CONTROL MEASURES AND CLEAN SEDIMENT AND DEBRIS FROM ENTIRE DRAINAGE AND SEWER SYSTEMS. Existing Conditions Information BASE PLAN: THE PROPERTY LINES SHOWN WERE DETERMINED BY A FIELD SURVEY CONDUCTED BY VHB. THE TOPOGRAPHY AND PHYSICAL FEATURES ARE BASED ON A FIELD SURVEY PERFORMED ON THE GROUND BY VHB IN FALL OF 2017. A.DELINEATION OF THE WETLANDS AND PLACEMENT OF THE FLAGS WAS PERFORMED BY: VHB. B.FLAGS MARKING THE WETLANDS WERE LOCATED BY: VHB. 2.TOPOGRAPHY: ELEVATIONS ARE BASED ON NAVD 88. 3.TEST PIT LOCATIONS AND ELEVATIONS WERE PERFORMED BY VHB. Document Use 1.THESE PLANS AND CORRESPONDING CADD DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE, AND SHALL NOT BE USED, IN WHOLE OR IN PART, FOR ANY PURPOSE OTHER THAN FOR WHICH IT WAS CREATED WITHOUT THE EXPRESSED, WRITTEN CONSENT OF VHB. ANY UNAUTHORIZED USE, REUSE, MODIFICATION OR ALTERATION, INCLUDING AUTOMATED CONVERSION OF THIS DOCUMENT SHALL BE AT THE USER'S SOLE RISK WITHOUT LIABILITY OR LEGAL EXPOSURE TO VHB. 2.CONTRACTOR SHALL NOT RELY SOLELY ON ELECTRONIC VERSIONS OF PLANS, SPECIFICATIONS, AND DATA FILES THAT ARE OBTAINED FROM THE DESIGNERS, BUT SHALL VERIFY LOCATION OF PROJECT FEATURES IN ACCORDANCE WITH THE PAPER COPIES OF THE PLANS AND SPECIFICATIONS THAT ARE SUPPLIED AS PART OF THE CONTRACT DOCUMENTS. 3.SYMBOLS AND LEGENDS OF PROJECT FEATURES ARE GRAPHIC REPRESENTATIONS AND ARE NOT NECESSARILY SCALED TO THEIR ACTUAL DIMENSIONS OR LOCATIONS ON THE DRAWINGS. THE CONTRACTOR SHALL REFER TO THE DETAIL SHEET DIMENSIONS, MANUFACTURERS' LITERATURE, SHOP DRAWINGS AND FIELD MEASUREMENTS OF SUPPLIED PRODUCTS FOR LAYOUT OF THE PROJECT FEATURES. Notes ELECTRIC VEHICLE PARKING of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Legend and General Notes C1.00 2 SMW PBS Issued for Construction 10/17/2022 PBS1 WIL L I S T O N R O A D TO I-89 LIMITS OF FUTURE RIGHT OF WAY EXISTING PROPERTY LINE PROPOSED 7'x12.5' TRANSFORMER PAD LOCATION (K30.3 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS PROPOSED 4'X10' GENERATOR PAD PROPOSED 8'x15' TRANSFORMER PAD LOCATION (K30.6 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS PROPOSED 7'x12.5' TRANSFORMER PAD LOCATION (K30.3 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS PEDESTRIAN PUSH BUTTON PEDESTAL. LOCATION AND WIRING TO BE COORDINATED WITH ENGINEER AND SOUTH BURLINGTON DPW PR I M A R Y B U I L D I N G F A C A D E 12' PLAZA 8' WIDE MULTI-USE PATH LA LA LA LA LA LA LA LA TOTAL GSF = 59,815 SF FFE = 313.95' (RENOVATION OF EXISTING BUILDING) PROPOSED LOBBY ADDITION TOTAL GSF = 136,561 SF FFE = 313.9' PROPOSED POOL ADDITION LALA LA LA LA R15.0' R18.3' R229.5' R221.5' R15.0' R30.0' R49.5' R100.0' R5.0' R5.0' R5.0' R5.0' R5.0' R3.0'R5.0'R5.0' R5.0' R5.0' R10.0' R199.5' R3.0' R100.0' R94.0'R55.0' R65.6' R21.0' R7-8 TYPE B END CURB FLUSH CURB FLUSH CURB BEGIN TRANSITION CURB BEGIN TRANSITION CURB BEGIN TRANSITION CURB R12.0' R34.0' R5.0' R10.0' R5.0' FLUSH CURB BEGIN MOUNTABLE CURB END MOUNTABLE CURB 18'X25' CONCRETE DUMPSTER PAD WITH ENCLOSURE 18" GRAVEL SUBBASE 24" GRAVEL SUBBASE 24 " G R A V E L SU B B A S E "F I R E L A N E " BEGIN TRANSITION CURB END PERMANENT SIDEWALK TEMPORARY CONCRETE SIDEWALK AND CURB, EXTEND TO FULL HEIGHT CURB 10 23 23 22 12 8 3 2 16 13 13 FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING TOTAL GSF = 83,927 SF FFE = 314.5' HAMPTON INN2 END CURB TEMPORARY DRIVE AISLE 22 ' - 0 " 22'-0" 8'- 0 " 20'-0" R10.0' 20' TEMPORARY DRIVE AISLE 20' TEMPORARY DRIVE AISLE R50' R20' R30' SIX (6) U-RACKS (12 SPACES TOTAL) EXISTING PROPERTY LINE LIMITS OF FUTURE ROW LIMITS OF PHASE 2A WOOD GUARDRAIL RELOCATED CHAIN LINK FENCE 1.5'x3' COMMUNICATIONS PEDESTAL (2) 2.2'X3.2' COMMUNICATIONS VAULT (2) 1' MIN. SEPARATION 2' MIN. SEPARATION A B C DABCD A B C D 6' WIDE TEMPORARY ASPHALT PATH of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Proposed Site Plan C2.01 3 CHS PBS Feet6030015 Parking Summary Chart Description Spaces Existing Proposed NOTE: SNOW STORAGE WILL BE LOCATED ONSITE WHERE SHOWN. EXCESS SNOW WILL BE MOVED TO AN OFFSITE LOCATION IN RESPONSE TO THE FACILITY PARKING NEEDS. NOTE: CITY PARKING REQUIREMENT FOR RESIDENTIAL: 0.75 SPACES/1-BR-STUDIO-UNIT + 1.5 SPACES/2-BR-UNIT+ 0.75 SPACES/4 UNITS =(0.75*72 UNITS)+(1.5*11 UNITS)+ ((0.75)*(83 UNITS/4) = 86 RESIDENTIAL SPACES REQUIRED Zoning Summary Chart Zoning District(S):Form Based Code - Transect Zone 4 Overlay District(S):Major Intersections - Zone 1, Transit Overlay District Zoning Regulation Requirements Existing Required Provided Revised Intersection 04/20/2023 DJH3 Phase 2A Limits and Temp Drive Aisle 06/08/2023 DJH4 Revised Phase 2A Limits and Temp Drive Aisle 09/14/2023 DJH6 Revised Phase 2A Limits 10/31/2023 DJH8 Revised Phase 2A Limits / Courtyard 12/12/2023 DJH9 Ground Floo r Second Flo o r PR I M A R Y B U I L D I N G F A C A D E 12' PLAZA EASEMENT E (WINDJAMMER ENTRY ROAD APPROX. 7,994 SF (0.184 AC)) EASEMENT FROM CHAMPLAIN SCHOOL APARTMENTS TO WINDJAMMER PROPOSED 10' TEMPORARY CONSTRUCTION EASEMENT 3,728 SF (0.086 AC) EASEMENT A (ROADWAY EASEMENT APPROX. 2,341 SF (0.054 AC)) WINDJAMMER EASEMENT TO CHAMPLAIN SCHOOL APARTMENTS PROPOSED 10' WIDE MULTI-USE PATH 6'5'8'10'10'8'6'6' 60' 36' 6'-16' SIDEWALK 5' MIN. GREENBELT 8' MAX. PARKING LANE 9'-12' TRAVEL LANE 9'-12' TRAVEL LANE 8' MAX. PARKING LANE 5' MIN. GREENBELT 6'-16' SIDEWALK 36'-66' PAVEMENT WIDTH 60' MIN. STREET ROW WIDTH R15'R15' PR O P O S E D F U T U R E SU P P O R T S T R E E T EXISTING PROPERTY LINE TOTAL GSF = 59,815 SF FFE = 313.95' (RENOVATION OF EXISTING BUILDING) PROPOSED LOBBY ADDITION PRIMARY BUILDING FACADE SE C O N D A R Y B U I L D I N G F A C A D E SE C O N D A R Y S T R E E T B U I L D T O Z O N E PRIMARY BUILD TO ZONE TOTAL GSF = 136,561 SF FFE = 313.9' PRO P O S E D F U T U R E C I T Y S T R E E T 8 3 FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING TOTAL GSF = 83,927 SF FFE = 314.5' FUTURE PHASE HAMPTON INN2 A B C D of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Proposed Future Support Street Plan C2.04 4A CHS PBS Feet4020010 Local Comments 8/30/21 SMW1 Local Comments 9/23/21 SMW2 Local Comments 12/12/23 DJH3 WIL L I S T O N RO A D TO I-89 5' DIA. TOTAL GSF = 59,815 SF FFE = 313.95' TOTAL GSF = 136,561 SF FFE = 313.9' FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING REMOVE EXISTING DRIVEWAY, RESTORE TO PERVIOUS GRASS SURFACE, GRADE TO DRAIN 12" MIN. TOTAL SOIL DEPTH (4" MIN TOPSOIL) TOTAL GSF = 59,815 SF FFE = 313.95' TOTAL GSF = 136,561 SF FFE = 313.9' FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING (RENOVATION OF EXISTING BUILDING) LIMITS OF PHASE 2A 312.2313.3 313 TC312.5 BC 310.5 TC 310 BC 309.5 TC 309 BC 308.5 309 TC 308.5 BC 312.8 313.65 TC/BC 314.3 TC313.7 BC 313.7 313.2 314.2 TC313.6 BC 313.8 313.7 313.7 313.9313.9 313.85313.85 310.5 TC 311.5 TC 313.3 GT D GT D 313.3 314.1 314.7314.6 314.3314.2 312.15 313.3313.4 313.9 313.7 TC313.2 BC 313.8 TC313.3 BC 313.75 313.5 TC313.0 BC 313.9 310 TC309.5 BC 312.5 TC312 BC309 TC 313.9 313.9 313.9 313.75 313.75 TC313.25 BC 313.8 TC313.3 BC 313.8 TC 313.3 BC 312.6 TC 312.7 314.0 314.2 TC313.6 BC 313.45 314.0 313.65 TC/BC 313.7 312.8 313.0 312.6 312.7 312.6 313.4 313.1313.3312.7 312.5 312.5312.1 313.2 313.5 313.5 313.0 EDGE OF DELINEATED WETLAND (TYP) 2013-3 50-FT WETLAND BUFFER (TYP) Br Fu HlB AdE AdA ScB 8" P V C 6 RIM=313.3 INV=308.2 OUT 7RIM=313.5 INV=308.4 INV=308.2 7B OUT CB 3 RIM=311.9 INV=306.6 OUT CB 4RIM=311.9 INV=306.6 OUT CB 15RIM=308.2 INV=304.8 INV=305.1 OUT CB 12RIM=312.8 INV=306.2 INV=306.2 INV=306.1 13 RD3 OUT CB 18 RIM=313.2 INV=308.3 INV=308.5 INV=308.5 INV=308.2 INV=308.5 17 21 6 IN OUT OUT DMH 17 RIM=313.0 INV=309.0 INV=309.0 INV=309.0 INV=309.0 RD2 16 DS3 OUT CB 19 RIM=312.5 INV=308.3 INV=308.2 INV=309.0 INV=308.5 20 OUT OUT DMH 20 RIM=312.1 INV=308.5 OUT CB REMOVE EXISTING PIPE AND CONNECT TO EXISTING STRUCTURE AT INV=302.0 15"H D P E 18"HDPE 18"HDPE 15"HDPE 15"PVC REMOVE EXISTING GREASE TRAP AND MANHOLE 21 RIM=312.6 INV=309.2 OUT CB 1A RIM=312.4 INV=302.3 1B DMH 24 " H D P E ELIMINATE EXISTING OUTFALL. PLUG OUTLET. BACKFILL PIPE WITH FLOWABLE FILL. COORDINATE ALL WORK WITH VTRANS. 2% M I N . SL O P E 2RIM=312.4 INV=306.4 INV=306.4 INV=304.4 INV=304.3 4 3 5 OUT DMH16RIM=313.1 INV=309.4 OUT CB 13RIM=312.6 INV=308.6 INV=308.5 13 B OUT CB 12 " H D P E 15"HDPE 15 " H D P E 15 " H D P E 1 5 " H D P E 15"HDPE 22 RIM=312.4 INV=307.2 INV=305.0 19 OUT DMH 15"HDPE 8 " P V C 5 RIM=313.6 INV=307.5 INV=307.5 INV=308.1 INV=305.5 6 7 1 6 OUT DMH 10"PVC 7B RIM=313.3 INV=308.8 INV=308.6 7A OUT CB 12" H D P E 12" HDPE ROOF DRAIN CONNECTION 15 " H D P E SUBSURFACE INFILTRATION SYSTEM #1 SUBSURFA C E INFILTRATIO N SYSTEM #2 1 5 " H D P E 13 B RIM=312.0 INV=308.7 OUT CB 6"PV C 18"HDPE 14ARIM=309.9 INV=304.9 INV=304.8 INV=305.1 INV=304.8 11 OUT OUT OUT CB 11 RIM=312.5 INV=306.0 INV=305.7 INV=305.6 RD4 12 OUT CB 1B RIM=312.4 INV=302.5 INV=302.4 2 OUT DMH 12 " P V C 18"HDPE 15"HDPE 15"HDPE CORE NEW INVERT AT 305.2 ADD RISER SECTION, MANHOLE FRAME, AND COVER, AND ADJUST TO FINISH GRADE. OUT (W) (E) (N) 14B RIM=310.0 INV=304.7 INV=305.7 INV=304.7 14A OUT OUT DMH (EX CB#1) (N) (S) (E) 12"HDPE12"HDPE 12"HDPE 12"HDPE 12"HDPE 8"PVC 12 " H D P E 8" P V C 8"PVC 8" P V C 8"PVC 12"H D P E CO CO GMP TO HOLD EXISTING POLE AND REINSTALL GUY WIRE. COORDINATE DRAINAGE WORK WITH GMP. RD INV=307.0 4" S D R 3 5 P V C @ 1 % M I N . CANOPY DRAIN INV=309.5 WYE INTO 12" HDPE BENDS AS NECESSARY 24 RIM=313.1 INV=300.1 INV=300.1 INV=300.0 23 OUT DMH 12"HDPE 12 " H D P E AS-BUILT INV W/ CAP = 300.6 FES INV = 299.0 18 " H D P E (2) 6" SDR 35 PVC. INV. = 309.2 EXTEND 6" PVC 5' BEYOND PHASE 2A PAVERS AND WITNESS FIELD VERIFIED LOCATION OF CWD WATER MAIN REMOVE EXISTING WATER SERVICE, VALVES AND HYDRANT. SHUTDOWN OF THIS LINE SHALL BE PERFORMED BY CWD/SBWD PERSONNEL ONLY. EXISTING HYDRANT 8" DI FIRE SERVICE. COORDINATE WITH MECHANICAL PLANS FIRE DEPARTMENT CONNECTION LOCATION (CONFIRM WITH SPRINKLER DESIGNER) 4" DOMESTIC SERVICE. FINAL SIZE PER MECHANICAL PLANS HYDRANT 8" GATE VALVE CAP LINE FOR FUTURE CONSTRUCTION 8x3 TEE 8" GATE VALVE EXISTING 8" DI WATER SERVICE 3" GATE VALVE 8x8 TEE 8X6 TEE NEW HYDRANT NEW 8" DI WATER MAIN REMOVE EXISTING WATER SERVICE. PROPOSED 8"x8" CUT-IN-TEE WITH VALVE CLUSTER NEW 8" D.I. CL52 WATER MAIN 6" GATE VALVE NEW 8" DI WATER MAIN 8" GATE VALVE 6" GATE VALVE 6" GATE VALVE 8" TO 6" REDUCER INV W/ CAP = 307.61 7A RIM=313.1 INV=310.0 OUT CB 12 " H D P E 8" D.I. CL52 WATER MAIN STUB (CAP WITH THRUST BLOCK) 8x8 TEE 10" SDR 35 PVC ROOF DRAIN INV = 309.8 CAP FOR FUTURE CONNECTION TEMPORARY 6" PERFORATED SDR35 PVC INFILTRATION TRENCH 8" SDR35 PVC INV. = 307.5 STUB, CAP AND WITNESS 8x6 TEE 8" TO 4" REDUCER 4" GATE VALVE 2% M I N . SL O P E 8" SDR35 PVC INV. = 304.5 STUB, CAP AND WITNESS CO INV.=309.3 CANOPY DRAIN INV.=309.5 CANOPY DRAIN INV.=309.4 CANOPY DRAIN INV.=310.0 CO INV=309.8 6" SDR 35 PVC @ 0.5% MIN. 15" HDPE INV. = 308.9. STUB, CAP AND WITNESS S 7 5 ° 5 6 ' 2 6 " W 300 305 310 NRCS Soils Summary SYMBOL SOIL NAME HYDROLOGIC GROUP HYDRIC SOILS FARMLAND SOIL AdA ADAMS AND WINDSOR LOAMY SANDS, 0 TO 5 PERCENT SLOPES A NO STATEWIDE AdE ADAMS AND WINDSOR LOAMY SANDS, 30 TO 60 PERCENT SLOPES A NO NPSL Br BORROW PITS N/A N/A NPSL Fu FILL LAND A N/A NPSL HlB HARTLAND VERY FINE SANDY LOAM, 2 TO 6 PERCENT SLOPES C/D YES STATEWIDE, IF DRAINED ScB SCANTIC SILT LOAM, 2 TO 6 PERCENT SLOPES C/D YES STATEWIDE, IF DRAINED of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Grading and Drainage Plan C3.01 4 CHS PBS Feet6030015 Revised Storm Drain per NDMFII Design 06/28/2023 DJH5 Revised Phase 2A Limits and Temp Drive Aisle 09/14/2023 DJH6 Temp Drive Aisle Grading 10/04/2023 DJH7 Added Wetland Buffer / Revised Phase 2A Limits 10/31/2023 DJH8 Revised Phase 2A Limits / Courtyard 12/12/2023 DJH9 312.2 314.3 TC313.7 BC 314.2 TC313.6 BC 314.1 314.7 314.6 314.3 314.2 312.15 313.3 313.4 312.7 312.1 312.1 3 1 2 . 1 5 312.0 TC 312.6 312.5 312.0 312. 1 312. 2 312.6 TC 312.7 312. 5 312 . 4 312 . 7 100+0 0 101+00 102+00 PC PT +92.6 0 +38.57 314.0 314.0 WIL L I S T O N R O A D 5' DIA. REMOVE EXISTING DRIVEWAY, RESTORE TO PERVIOUS GRASS SURFACE, GRADE TO DRAIN 12" MIN. TOTAL SOIL DEPTH (4" MIN TOPSOIL) 8" P V C 15"H D P E 18"HDPE 24 " H D P E 2% M I N . S L O P E 15 " H D P E 15 " H D P E 1 5 " H D P E 10"PVC 12" H D P E HYDRANT REMOVE EXISTING WATER SERVICE. PROPOSED 8"x8" CUT-IN-TEE WITH VALVE CLUSTER NEW 8" D.I. CL52 WATER MAIN CONCRETE ENCASED CONDUIT SLEEVE. CONTRACTOR SHALL COORDINATE WITH TELECOM UTILITIES ON REQUIRED CONDUIT SIZE AND MATERIALS 8" D.I . C L 5 2 W A T E R M A I N 4 RIM=311.9 INV=306.6 OUT CB 3RIM=311.9 INV=306.6 OUT CB 2 RIM=312.4 INV=306.4 INV=306.4 INV=304.4 INV=304.3 4 3 5 OUT DMH EX SMH#2 RIM=312.2 EX INV=306.2 4" PVC EX INV=302.7 10" PVC EX INV=302.5 10" PVC EX INV=302.5 10" PVC CORE AND BOOT NEW HOLE AT INV 303.0 ADJUST RIM TO FINISHED GRADE 8" SDR35 PVC INV. = 304.5 STUB, CAP AND WITNESS of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Intersection Grading Plan C3.02 5 CHS PBS Feet201005 Revised Road Grading, Storm and Watermain 04/20/2023 DJH3 Revised Watermain Tie-In Tee Location 05/23/2023 DJH4 WIL L I S T O N R O A D TO I-89 FUTURE PHASE PROPOSED UNDERGROUND ELECTRICAL SERVICE. PROPOSED TRANSFORMER PAD LOCATION (K30.6 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS REMOVE EXISTING GREASE TRAP AND MANHOLE 2% M I N . SL O P E EXISTING 8x8 TEE 8" DI FIRE SERVICE. COORDINATE WITH MECHANICAL PLANS EXISTING GMP LIGHTING, POLES AND SERVICE TO BE REMOVED AND REPLACED WITH NEW POLES AND SERVICES BY OWNER. REFER TO LIGHTING PLANS AND COORDINATE WITH GMP AND ELECTRICAL PLANS. REMOVE EXISTING OVERHEAD ELECTRICAL SERVICE. COORDINATE WITH GMP PROPOSED 4'X10' GENERATOR PAD PROPOSED TRANSFORMER PAD LOCATION (K30.3 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS MIN. 2" DOMESTIC SERVICE. FINAL SIZE PER MECHANICAL PLANS 3-PHASE CONCRETE ENCASED CONDUIT TRANSFORMER PAD LOCATION (K30.3 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS THREE PHASE ELECTRICAL SERVICE. CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS THREE PHASE ELECTRICAL SERVICE. CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS REMOVE EXISTING UTILITY POLE AND OVERHEAD ELECTRICAL SERVICE. COORDINATE WITH GMP AND ENGINEER S2 RIM=313.9 INV=303.1 INV=304.4 INV=303.00 8"IN 8"IN OUT SMH 2" PE GAS MAIN 8" GATE VALVE CONSTRUCTED 6" DI WATER SERVICE. 6" GATE VALVE GAS METERS 8"x6" REDUCER TIE-IN TO EXISTING STEEL WITH 4" TRANSITION FITTING. 4"X2" REDUCER 3/4" PE GAS SERVICE 3/4" PE GAS SERVICE 3/4" PE GAS SERVICE END MAIN WITH 2" PURGE POINT CAP. LOC. BOX OVER END. CAP FOR FUTURE CONNECTION 1.5'x3' COMMUNICATIONS PEDESTAL (2) 2.2'x3.2' COMMUNICATIONS VAULT (2) A B C DABCD A B C D 6' MIN.PROVIDE 10' CLEARANCE THIS SIDE OF TRANSFORMER FIELD VERIFIED LOCATION OF CWD WATER MAIN REMOVE EXISTING WATER SERVICE, VALVES AND HYDRANT. SHUTDOWN OF THIS LINE SHALL BE PERFORMED BY CWD/SBWD PERSONNEL ONLY. EXISTING HYDRANT 8" DI FIRE SERVICE. COORDINATE WITH MECHANICAL PLANS FIRE DEPARTMENT CONNECTION LOCATION (CONFIRM WITH SPRINKLER DESIGNER) 4" DOMESTIC SERVICE. FINAL SIZE PER MECHANICAL PLANS HYDRANT 8" GATE VALVE CAP LINE FOR FUTURE CONSTRUCTION 8x3 TEE 8" GATE VALVE EXISTING 8" DI WATER SERVICE 3" GATE VALVE 8x8 TEE 8X6 TEE NEW HYDRANT NEW 8" DI WATER MAIN REMOVE EXISTING WATER SERVICE. PROPOSED 8"x8" CUT-IN-TEE WITH VALVE CLUSTER NEW 8" D.I. CL52 WATER MAIN 6" GATE VALVE NEW 8" DI WATER MAIN 8" GATE VALVE 6" GATE VALVE 6" GATE VALVE 8" TO 6" REDUCER CONCRETE ENCASED CONDUIT SLEEVE. CONTRACTOR SHALL COORDINATE WITH TELECOM UTILITIES ON REQUIRED CONDUIT SIZE AND MATERIALS 8" D.I. CL52 WATER MAIN STUB (CAP WITH THRUST BLOCK) 8x8 TEE 8" SDR35 PVC INV. = 307.5 STUB, CAP AND WITNESS S3 RIM=313.85 INV=306.9 INV=306.8 NDMF II OUT SMH 8x6 TEE 8" TO 4" REDUCER 4" GATE VALVE 2% M I N . SL O P E 8" SDR35 PVC INV. = 304.5 STUB, CAP AND WITNESS 30+50.55 30+00 12+03.02 10+00 11+00 12+00 HOLIDAY INN HAMPTON INN MULTI-USE BUILDING LIMITS OF PHASE 2A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Utility Plan C4.01 6 CHS PBS NOTE: 1.CONTRACTOR SHALL NOTIFY ENGINEER AND CWD AT LEAST 5 DAYS PRIOR TO WORK WITHIN 10 FEET OF CWDs TRANSMISSION MAIN. 2.CONTRACTOR SHALL PROVIDE SHEETING/SHORING SUPPORT DURING STRUCTURE EXCAVATION WHEN EXCAVATION IS WITHIN 10 FEET OF THE CWD TRANSMISSION MAIN. 3.ALL BUILDING SEWER SERVICES AND ROOF DRAINS SHALL HAVE A MINIMUM PIPE SLOPE OF 2% FROM THE BUILDING TO THE SEWER MAIN OR CONNECTION MANHOLE. 4.ALL WATER LINES AND APPURTENANCES SHALL BE INSTALLED IN ACCORDANCE WITH THE CHAMPLAIN WATER DISTRICT SPECIFICATIONS AND DETAILS FOR THE INSTALLATION OF WATER LINES AND APPURTENANCES, CURRENT EDITION 5.CONTRACTOR SHALL CONFIRM ALL BUILDING UTILITY SERVICE LOCATIONS WITH THE PROJECT MEP PRIOR TO INSTALLATION Feet6030015 Revised Telecom Water main and Sewer 06/08/2023 DJH4 Revised Sanitary Structure S3 08/14/2023 DJH5 Rvised Phase 2A Limits and Temp Drive Aisle 09/14/2023 DJH6 Revised Phase 2A Limits 10/31/2023 DJH8 Revised Phase 2A Limits / Courtyard 12/12/2023 DJH9 EXISTING GRADEFINISH GRADE El e v a t i o n s El e v a t i o n s Station Station 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 100+00100+10100+20100+30100+40100+50100+60100+70100+80100+90101+00101+10101+20101+30101+40101+50101+60101+70101+80101+90102+00102+10102+20102+30102+36 31 2 . 0 31 3 . 4 9 31 2 . 4 31 3 . 7 9 PVI STA = 101+87.56 PVI ELEV = 313.60 A.D. = 3.03% K: 8.25 25.00' VC BV C S : 1 0 1 + 7 5 BV C E : 3 1 3 . 8 0 EV C S : 1 0 2 + 0 0 EV C E : 3 1 3 . 7 9 LOW PT ELEV = 313.70 LOW PT STA = 101+88.02 PVI STA = 101+50.29 PVI ELEV = 314.19 A.D. = -2.96% K = 8.44 25.00' VC BV C S : 1 0 1 + 3 8 BV C E : 3 1 4 . 0 1 EV C S : 1 0 1 + 6 3 EV C E : 3 1 3 . 9 9 HIGH PT STA: 101+49.54 HIGH PT ELEV: 314.10 PVI STA = 102+31.26 PVI ELEV = 314.24 A.D. = -2.86% K = 8.73 25.00' VC BV C S : 1 0 2 + 1 9 BV C E : 3 1 4 . 0 6 EV C S : 1 0 2 + 4 4 EV C E : 3 1 4 . 0 7 HIGH PT STA: 102+31.50 HIGH PT ELEV: 314.15 -1.57% 1.39% 1.46% 5 R= 3 1 3 . 6 IN V = 3 0 7 . 5 0 IN V = 3 0 7 . 5 0 IN V = 3 0 8 . 1 0 IN V = 3 0 5 . 5 0 6 7 1 6 OU T 6 R= 3 1 3 . 3 IN V = 3 0 8 . 2 0 OU T 7 R= 3 1 3 . 5 IN V = 3 0 8 . 4 0 IN V = 3 0 8 . 2 0 7B OU T RAISE RIM OF EXISTING STRUCTURE TO FINISHED GRADE WITH NEW COVER SECTION AND PRECAST RISER RINGS. 12" MAX OF RISER RINGS 2 R= 3 1 2 . 4 IN V = 3 0 6 . 4 0 IN V = 3 0 6 . 4 0 IN V = 3 0 4 . 4 0 IN V = 3 0 4 . 3 0 4 3 5 OU T 4 R= 3 1 1 . 9 IN V = 3 0 6 . 6 0 OU T 3 R= 3 1 1 . 9 IN V = 3 0 6 . 6 0 OU T 30 LF 15"HDPE S=0.66% 146 LF18"HDPES=0.75% 70 LF10"PVCS=0.79% EXISTING SANITARY SEWER PIPE (S 7 ) R= 3 1 2 . 6 IN V = 3 0 1 . 6 8 IN V = 3 0 1 . 5 8 (S 8 ) OU T 312.2 314.3 TC313.7 BC 313.7 314.2 TC313.6 BC 12 + 0 0 12 + 2 4 . 1 6 PI +96.06 20+00 20 + 4 0 . 5 7 PI PI +07.05 +15 . 1 0 314.1314.6 314.2 312.15 313.3 313.4 312.1 312.1 3 1 2 . 1 5 312.0 TC 312.6 312.5 312.0 312 . 1 312. 2 312.6 312 . 5 312. 4 102+35.98 100+ 0 0 101+0 0 102+00 PC PT +92.6 0 +38.57 314.0 313.45 313.65 TC/BC 313.7 5' DIA. REMOVE EXISTING DRIVEWAY, RESTORE TO PERVIOUS GRASS 8" P V C 15"HD P E 18"HDPE2% M I N . S L O P E 15 " H D P E 15 " H D P E 1 5 " H D P E 10"PVC 12" H D P E REMOVE EXISTING WATER SERVICE. PROPOSED 8"x8" CUT-IN-TEE WITH VALVE CLUSTER CONCRETE ENCASED CONDUIT SLEEVE. CONTRACTOR SHALL COORDINATE WITH TELECOM UTILITIES ON REQUIRED CONDUIT SIZE AND MATERIALS 8" D.I. C L 5 2 W A T E R M A I N 8x8 TEE 4 RIM=311.9 INV=306.6 OUT CB 3 RIM=311.9 INV=306.6 OUT CB 2RIM=312.4 INV=306.4 INV=306.4 INV=304.4 INV=304.3 4 3 5 OUT DMH EX SMH#2 RIM=312.2 EX INV=306.2 4" PVC EX INV=302.7 10" PVC EX INV=302.5 10" PVC EX INV=302.5 10" PVC CORE AND BOOT NEW HOLE AT INV 303.0 ADJUST RIM TO FINISHED GRADE 8x6 TEE 8" SDR35 PVC INV. = 304.5 STUB, CAP AND WITNESS of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Roadway Profile Plan C5.01 7 SMW PBS Vert. Horiz.Feet201005 Feet4201 Revised Road Grading, Storm and Watermain 04/20/2023 DJH3 Rev. Water Tie-In Tee & Future Phase Connnection 06/08/2023 DJH4 El e v a t i o n s El e v a t i o n s Station Station WATERLINE-3-NEW 300 310 320 300 310 320 10+00 11+00 12+00 13+00 13+11 El e v a t i o n s El e v a t i o n s Station Station WATERLINE-1-NEW 300 310 320 300 310 320 10+00 11+00 12+00 13+00 14+00 14+11 31 3 . 3 31 3 . 6 2 31 3 . 2 31 3 . 5 1 31 3 . 1 31 3 . 0 6 31 3 . 0 31 3 . 0 1 El e v a t i o n s El e v a t i o n s Station Station WATERLINE-2-NEW 300 310 320 300 310 320 10+00 10+92 31 1 . 9 31 3 . 0 1 31 3 . 3 31 3 . 9 9 8" DI CL52 MIN. 6' COVER EXISTING 8"x8" TEE EXISTING 8" GATE VALVE 8" GATE VALVE 8"X2" TEE CAP WATER LINE FOR FUTURE CONSTRUCTION (TYP OF 2) PROPOSED GRADE EXISTING GRADE EXISTING 8" WATER MAIN 8"x8" CUT-IN-TEE 18" MIN. SEPARATION 15" STORM DRAIN EXISTING 10" SEWER 12" STORM DRAIN 4" ROOF DRAIN PROPOSED GRADEEXISTING GRADE MIN. 6' COVER 8" DI CL52 WATERMAIN 8" DI CL52 8" GATE VALVE 18" MIN. SEPARATION 18" MIN. SEPARATION 18" MIN. SEPARATION PROPOSED 8" SEWER MIN. 6' COVER 8"x8"TEE (TO STUB) 8"x6"TEE (TO FIRE HYDRANT) 8"x8"TEE (TO BUILDING) REFER TO PLUMBING DRAWINGS FOR CONTINUATION WITHIN BUILDING 4" GATE VALVE 8" TO 4" REDUCER EXISTING 8"x8" TEE EXISTING 8" GATE VALVE 18" MIN. SEPARATION 3/4" PE GAS SERVICE 15" STORM DRAIN 6" ROOF DRAIN EXISTING UNDERGROUND ELECTRIC EXISTING UNDERGROUND ELECTRIC / TELECOM 3/4" PE GAS SERVICE THREE PHASE ELECTRICAL SERVICE THREE PHASE CONCRETE ENCASED CONDUIT MIN. 6' COVER PROPOSED GRADE EXISTING GRADE 15" STORM DRAIN FIRE HYDRANT 8"x4" TEE (DOMESTIC SERVICE TO BLDG) 8" GATE VALVE 18" MIN. SEPARATION 6" GATE VALVE 8" TO 6" REDUCER PROPOSED UNDERGROUND ELECTRIC PROPOSED UNDERGROUND ELECTRIC 8"x8" TEE (FIRE SERVICE TO BLDG) of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Waterline Profiles Plan C5.02 8 SMW PBS Vert. Horiz.Feet201005 Feet4201 Revised Telecom, Storm Drain & Water Main 03/10/2023 DJH2 Revised Water Main Profile 04/20/2023 DJH3 Revised Water Main Profile 05/23/2023 DJH4 El e v a t i o n s El e v a t i o n s Station Station Proposed Sewer 300 310 320 300 310 320 10+00 11+00 12+0012+03 70 LF 10"PVC S=0.79% EXISTING SURFACE PROPOSED SURFACE 15" HDPE DRAINAGE PIPE 8" PVC SERVICE MIXED USE BUILDING IN RAISE RIM OF EXISTING STRUCTURE TO FINISHED GRADE WITH NEW COVER SECTION AND PRECAST RISER RINGS. 12" MAX OF RISER RINGS S3 R= 3 1 3 . 8 IN V = 3 0 6 . 9 0 IN V = 3 0 6 . 8 0 ND M F I I OU T 122 LF 8"PVC S=3.02% S2 R= 3 1 3 . 9 IN V = 3 0 3 . 1 0 IN V = 3 0 4 . 4 0 IN V = 3 0 3 . 0 0 S3 MU I N OU T 8" PVC SERVICE (FUTURE NDMF II) of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Sewer Profile Plan C5.03 9 SMW PBS Vert. Horiz.Feet201005 Feet4201 4 Revised Sanitary Sewer Profile 06/08/2023 DJH4 EXISTING 8x8 TEE 8" GATE VALVE CONSTRUCTED 6" DI WATER SERVICE. 6" GATE VALVE 8"x6" REDUCER S 7 5 ° 5 6 ' 2 6 " W 300 305 310 WIL L I S T O N R O A D TO I-89 SUBSURFACE INFILTRATION SYSTEM #1 SUBSURFAC E I N F I L T R A T I O N SYSTEM #2 FUTURE PHASE HOLIDAY INN MULTI-FAMILY BUILDING FUTURE PHASE POTENTIAL TEMPORARY SOIL STOCKPILE LOCATION PROJECT DEMARCATION (TYP) LIMIT OF DISTURBANCE (TYP) STANDARD SILT FENCE (TYP) INLET PROTECTION (TYP) SURROUND TEMPORARY SOIL STOCKPILE WITH FILTER SOCKS, GRAVEL BAGS, OR SILTFENCE. IF STOCKPILE IS TO REMAIN FOR MORE THAN 14 CONSECUTIVE CALENDAR DAYS STABILIZE WITH TEMPORARY MULCH MATERIAL. LIMITS OF VEGETATION PROTECTION LIMITS OF TREE PROTECTION (TYP) CONSTRUCTION LAYDOWN AREA LIMITS OF PHASE 2A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Erosion and Sediment Control Plan C6.01 10 CHS PBS Feet6030015 NOTE: 1.AREAS DRAINING TO STORMWATER INFILTRATION SYSTEMS OR BIORETENTION AREAS SHALL RECEIVE FINAL STABILIZATION PRIOR TO ALLOWING RUNOFF TO DRAIN TO THE TREATMENT SYSTEMS. Issued for Construction 10/17/2022 PBS1 Revised Phase 2A Limits 10/31/2023 DJH8 Revised Phase 2A Limits / Courtyard 12/12/2023 DJH9 Concrete Sidewalk N.T.S.Source: VHB LD_420 1/16 1.0% (MIN.) 1.5% (MAX.) NOTES 1.PROVIDE EXPANSION JOINTS 2.AT MIN. 30 FT. O.C. WITH PRE- FORMED JOINT FILLER. 3.PROVIDE TOOLED CONTROL JOINTS AT 6' O.C. 4.PROVIDE BROOM FINISH IN DIRECTION PERPENDICULAR TO CURB. CONCRETE SIDEWALK 12" PREFORMED EXPANSION JOINT BLDG. FACE, FIXED OBJECT, OR CONC. SIDEWALK SECTION EXPANSION JOINT SEALANT 12" 15" COMPACTED GRAVEL VTRANS 704.05A FINE. (21" THICKNESS WITHIN 10' OF BUILDING DOORS AND RAMPS) COMPACTED SUBGRADE VARIES 7" REVEAL CURB FINISH PAVEMENT 5" CEMENT CONCRETE 6" THICK WITHIN FUTURE ROW (8" THICK IN VEHICULAR AREAS) NOTE: CONCRETE FOR SIDEWALKS TO BE 4000 PSI TYPE II, 6% (1.5±) AIR ENTRAINED. FINISH GRADE SECTION EXPANSION JOINT DETAIL REV Cast In Place Concrete Curb (CIP) N.T.S.Source: VHB LD_404 1/16 SLOPE VARIES 18"9"12" 6" 18" 7" (TYP.) REV SLOPE1.5% (MA X . )1.0% (MIN . ) RAMP SIDEWALK 4' (MIN.)EDGE O F A C C E S S I B L E ROUTE LANDSCA P E D A R E A CUR B CU R B T R A N S I T I O N CUR B 2'-0" 2.35" (TYP.)* 0.9" (PROFILE) Accessible Curb Ramp (ACR) Type 'I-D' N.T.S.Source: VHB LD_508 1/16 2'-0" NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5 (1%MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPS SHALLBE 5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE 7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE INACCESSIBLE ROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP SECTION CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5' x 5'PASSING AREA SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING AT RAMP WHERE IT ABUTS ROADWAY, EXCEPT WHERE VERTICALCURBING IS INDICATED ON THE DRAWINGS TO BE INSTALLED AND SET FLUSH. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO THE ACCESSIBLE ROUTE. CU R B T R A N S I T I O N CUR B CURB T R A N S I T I O N CUR B RAM P 7.5% ( M A X . ) RAM P 7.5% ( M A X . ) 7.5% ( M A X . ) 7.5 % ( M A X . ) 1.5% (M A X ) 1.0% (MIN ) LAN D S C A P E VARIES UPUP TO 6'- 8 " 4' (MIN.) ACCESSIB L E WALKWAY 4' (M I N . ) R A M P 2.35" (TYP.)* 2.35" (TYP.)* 0.9" 0.2" (PROFILE) TRUNCATED DOMES (PLAN VIEW) *DIMENSIONS ARE CENTER TO CENTER REV Accessible Curb Ramp (ACR) Type 'K-D' N.T.S.Source: VHB LD_510 1/16 NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5(1% MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPSSHALL BE 5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE INACCESSIBLE ROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5' x5' PASSING AREA SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING (OTHER THAN VERTICAL CURBING, WHICH SHALL BE SET FLUSH)WHERE IT ABUTS ROADWAYS. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO THE ACCESSIBLEROUTE. 0.9" 0.2"2.35" (TYP.)* 2.35" (TYP.)* LAN D S C A P E ARE A LAN D S C A P E AREA 2' C U R B T R A N S I T I O N 2' C U R B T R A N S I T I O N 4' ( M I N . ) RAM P 7 . 5 % A S R E Q ' D . 1.5% (MAX.) 1.0% (MIN.) RAM P 7 . 5 % ACC E S S I B L E WAL K W A Y 4' (MIN.)SIDEWALK 7.5% (MAX) RAMP CUR B CUR B 2'-0" (PROFILE) TRUNCATED DOMES *DIMENSIONS ARE CENTER TO CENTER REV Accessible Curb Ramp (ACR) Type 'A-D' N.T.S.Source: VHB LD_500 1/16 NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5 (1% MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPS SHALL BE 5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE 7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE IN ACCESSIBLE ROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB, AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5' x 5' PASSING AREASHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING AT RAMP (OTHER THAN VERTICAL CURBING, WHICH SHALL BE SET FLUSH) WHERE ITABUTS ROADWAY. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO ACCESSIBLE ROUTE. *2.35" TYP.0.2" 4' (M I N . ) 4' (MIN.)SIDEWAL K 2'-0" CU R B T R A N S I T I O N CUR B CURB T R A N S I T I O N CUR B (PROFILE) TRUNCATED DOMES (PLAN VIEW) *DIMENSIONS ARE CENTER TO CENTER REV Accessible Curb Ramp (ACR) - Type 'B-D' N.T.S.Source: VHB LD_501 1/16 NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5 (1% MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPS SHALL BE 5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE 7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE IN ACCESSIBLEROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5' x 5' PASSINGAREA SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING AT RAMP WHERE IT ABUTS ROADWAY, EXCEPT WHERE VERTICAL CURBING ISINDICATED ON THE DRAWINGS TO BE INSTALLED AND SET FLUSH. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO THE ACCESSIBLE ROUTE. 12.CONTRACTOR TO SUBMIT R.F.I. FOR THIS TYPE OF ACCESSIBLE CURB RAMP FOR APEX ROADWAYCROSSINGS. 0.2" 0.9" 2.35" (TYP.)* 2.35" (TYP.)* 7.5% ( M A X . ) CURBTRANSITIO N (2' MIN.) LANDSCAPE AREA (TYP.) 2'-0" SLOPE1.5% (MAX.)1.0% (MIN.)EDGE O F ACCESS I B L E R O U T E 4' (MIN.) SIDEWALK RAMP CURB T R A N S I T I O N CUR B (PROFILE) TRUNCATED DOMES (PLAN VIEW) *DIMENSIONS ARE CENTER TO CENTER REV Accessible Curb Ramp (ACR) Type 'C-D' N.T.S.Source: VHB LD_502 1/16 NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5 (1% MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPS SHALL BE5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE 7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE INACCESSIBLE ROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5' x 5'PASSING AREA SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING AT RAMP WHERE IT ABUTS ROADWAY, EXCEPT WHERE VERTICAL CURBINGIS INDICATED ON THE DRAWINGS TO BE INSTALLED AND SET FLUSH. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO THE ACCESSIBLE ROUTE. 12.CONTRACTOR TO SUBMIT R.F.I. FOR THIS TYPE OF ACCESSIBLE CURB RAMP FOR APEX ROADWAYCROSSINGS. 4' (MIN.) E D G E O F A C C E S S I B L E R O U T E EDGE O F ACCESS I B L E R O U T E 1.5% (MAX.) 1.0% (MIN.) 4' ( M I N . ) SID E W A L K RAM P 7.5% ( M A X . ) 7.5% (MAX.) RAMP SIDEWALK 4' (MIN.) 3' (MIN.) CURB TRANSITION CURB 2'-0" CURB T R A N S I T I O N CUR B 2.35" (TYP.)* 2.35" (TYP.)* 0.9"0.2" (PROFILE) TRUNCATED DOMES (PLAN VIEW) *DIMENSIONS ARE CENTER TO CENTER REV Accessible Curb Ramp (ACR) Type 'D-D' N.T.S.Source: VHB LD_503 1/16 7.5 % ( M A X . ) 7.5% ( M A X . ) SIDEWALK 10' (MIN.) SLO P E A S REQ ' D . SLOPE7.5% (MA X . ) 4' (MIN.)EDGE O F A C C E S S I B L E ROUTE SLO P E A S REQ ' D . SIDEWALK CURB T R A N S I T I O N CUR B 4' ( M I N . ) RAM P SLOPE1.5% (MA X . ) 1.0% (MIN . ) CUR B CU R B T R A N S I T I O N NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5 (1% MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPS SHALL BE 5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE 7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE INACCESSIBLE ROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5' x 5' PASSINGAREA SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING AT RAMP WHERE IT ABUTS ROADWAY, EXCEPT WHERE VERTICAL CURBING ISINDICATED ON THE DRAWINGS TO BE INSTALLED AND SET FLUSH. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO THE ACCESSIBLE ROUTE. 2.35" (TYP.)* 2.35" (TYP.)* 0.9"0.2" 2'-0" (PROFILE) TRUNCATED DOMES (PLAN VIEW) *DIMENSIONS ARE CENTER TO CENTER REV Accessible Curb Ramp (ACR) Type 'E-D' N.T.S.Source: VHB LD_504 1/16 NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5 (1% MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPS SHALL BE 5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE 7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE IN ACCESSIBLE ROUTE(I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5' x 5' PASSING AREASHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING AT RAMP WHERE IT ABUTS ROADWAY, EXCEPT WHERE VERTICAL CURBING ISINDICATED ON THE DRAWINGS TO BE INSTALLED AND SET FLUSH. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO THE ACCESSIBLE ROUTE. 12.CONTRACTOR TO SUBMIT R.F.I. FOR THIS TYPE OF ACCESSIBLE CURB RAMP FOR APEX ROADWAY CROSSINGS. 4' (MIN.) 4' (MIN.) 4' (MIN.) CUR B CU R B T R A N S I T I O N CURB T R A N S I T I O N CURB 7. 5 % ( M A X . ) RAMP SID E W A L K EDGE O F A C C E S S I B L E ROUTE 1.5% (MAX.) 1.0% (MIN.) SIDEWALK SLOPE 1.0% (M I N . ) 1.5% (M A X . ) 7.5 % ( M A X . ) 7.5% (M A X . ) 2.35" (TYP.)* 2.35" (TYP.)*0.9" 0.2" 2'-0" (PROFILE) TRUNCATED DOMES (PLAN VIEW) *DIMENSIONS ARE CENTER TO CENTER REV Accessible Curb Ramp (ACR) Type 'M' N.T.S.Source: VHB LD_512 1/16 NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5(1% MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPSSHALL BE 5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLEIN ACCESSIBLE ROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5'x 5' PASSING AREA SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING (OTHER THAN VERTICAL CURBING, WHICH SHALL BE SET FLUSH)WHERE IT ABUTS ROADWAYS. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO THE ACCESSIBLEROUTE. LAN D S C A P E ARE A LAN D S C A P E AREA 2' C U R B T R A N S I T I O N 2' C U R B T R A N S I T I O N 4' (M I N . ) 7.5% (MAX) RAMP ACC E S S I B L E SID E W A L K CUR B CUR B 2.35" (TYP.)* 2.35" (TYP.)* 0.9" 0.2" 2'-0" TRUNCATED DOMES (PLAN VIEW) 2.35" TYP. 0.9" RA M P 7.5 % ( M A X . ) RAM P 7.5% ( M A X . ) SLOPE1.5%(MAX.)1.0% (MIN.)SIDEWALK EDG E O F ACC E S S I B L E R O U T E (PROFILE) *DIMENSIONS ARE CENTER TO CENTER REV (PLAN VIEW) Accessible Curb Ramp (ACR) Type 'G-D' N.T.S.Source: VHB LD_506 1/16 NOTES 1.THE MAXIMUM ALLOWABLE SIDEWALK AND CURB RAMP CROSS SLOPES SHALL BE 1.5 (1%MIN.). 2.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE EXCLUDING CURB RAMPS SHALLBE 5%. 3.THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE AT CURB RAMPS SHALL BE 7.5%. 4.A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE IN ACCESSIBLE ROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.). 5.CURB TREATMENT VARIES, SEE PLANS FOR CURB TYPE. 6.RAMP, CURB AND ADJACENT PAVEMENTS SHALL BE GRADED TO PREVENT PONDING. 7.SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 8.WHERE ACCESSIBLE ROUTES ARE LESS THAN 5' IN WIDTH (EXCLUDING CURBING) A 5' x 5' PASSING AREA SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 200 FEET. 9.ELIMINATE CURBING AT RAMP WHERE IT ABUTS ROADWAY, EXCEPT WHERE VERTICALCURBING IS INDICATED ON THE DRAWINGS TO BE INSTALLED AND SET FLUSH. 10.DETECTABLE WARNINGS SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. 11.DETECTABLE WARNINGS SHALL BE INSTALLED PERPENDICULAR TO THE ACCESSIBLE ROUTE. 12.CONTRACTOR TO SUBMIT R.F.I. FOR THIS TYPE OF ACCESSIBLE CURB RAMP FOR APEXROADWAY CROSSINGS. 2' M I N . 4' M I N . R A M P 7.5% ( M A X . ) CURB T R A N S I T I O N 2.35" (TYP.)* 0.2" TRUNCATED DOMES (PLAN VIEW) *DIMENSIONS ARE CENTER TO CENTER REV Transition and End Curbs N.T.S.Source: VHB LD 2/17 7" 4'-0" TYPE 1 3"7" 3" TYPE 2 1/2" ISOLATION JOINT @ STRUCTURES DOWELED EXPANSION JOINT 1/2"WALL OR STRUCTURE SEALANT 3/4" DEEP PREFORMED JOINT FILLER FULL DEPTH OF SLAB #4 SMOOTH DOWEL BARS 18" LONG @ 12" O.C. AND PARALLEL PREFORMED JOINT FILLER FULL DEPTH OF SLAB DOWEL CAP W/ LUBRICANT THIS END SEALANT 3/4" DEEP #4 SMOOTH DOWEL BARS, 18" LONG @ 12" O.C. AND PARALLEL 6" EQ. 1/2" EQ. EQ. 1/2" EQ. 6" 1'-2" 1'-2"1'-2" 6" 6" DOWEL CAP W/ LUBRICANT, THIS END Concrete Joints N.T.S.Source: VHB LA 2/22 COMPACTED SUBGRADE COMPACTED GRAVEL VTRANS 704.05A FINE BIT. CONC. PAVEMENT TACK COAT 1/2" RADIUSCONCRETE CURB, TYPE B (PER VTRANS STANDARD C-10) TREATMENT VARIES TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS 14" LIP MAX. SEE NOTE 9. SEE NOTE 9. 14" LIP MAX. TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS SEE NOTE 9. 14" LIP MAX. TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS 14" LIP MAX. SEE NOTE 9. 14" LIP MAX. SEE NOTE 9. TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS 14" LIP MAX. SEE NOTE 9. TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS 14" LIP MAX. SEE NOTE 9 TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS 14" LIP MAX.TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS 14" LIP MAX. SEE NOTE 9. TRUNCATED DOMES ONLY WHERE SHOWN ON PLANS FINISHED GRADE OF PAVEMENT FINISHED GRADE OF PAVEMENT Mountable Cast In Place Concrete Curb (MCIP) N.T.S.Source: VHB LD_404 1/16 SLOPE VARIES 18"9"12" 6" 18" 6" COMPACTED SUBGRADE COMPACTED GRAVEL VTRANS 704.05A FINE BIT. CONC. PAVEMENT TACK COATCONCRETE CURB, TYPE A (PER VTRANS STANDARD C-10) TREATMENT VARIES #4 DEFORMED REINF. BARS 1" 6"3" 6" 1" 6" 1/4" RADIUS 2" RADIUS1/4" RADIUS of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Site Details 1 C7.01 11 SMW PBS Issued for Construction 10/17/2022 PBS1 Pavement Section (all other paved areas) N.T.S.Source: VHB LD_430S 1/16 COMPACTED GRAVEL 704.0B -12" AT NORTH PARKING LOT AND FIRE LANE (SEE PLANS) -18" ALL OTHER AREAS STANDARD DUTY FLEXIBLE PAVEMENT 2" BITUMINOUS CONCRETE PAVEMENT TYPE II 1 12" BITUMINOUS CONCRETE PAVEMENT TYPE III REV Crosswalk N.T.S.Source: VHB LD_553 1/16 ST O P L I N E (S E E P L A N S ) NOTES 1.TWELVE INCH (12") LINES SHALL BE APPLIED IN ONE APPLICATION, NO COMBINATION OF LINES (TWO - 6 INCH LINES) WILL BE ACCEPTED. 2.LONGITUDINAL CROSSWALK LINES TO BE PARALLEL TO CURBLINE. 3.ALL LONGITUDINAL CROSSWALK LINES TO BE THE SAME LENGTH AND PROPERLY ALIGNED. 4.CROSS WALK SIDESLOPE SHALL NOT EXCEED 1.5%. AL I G N 8' (TYP.) 2' (M A X . ) 2' (T Y P . ) MAX. SLOPE 1.5% 12" (TYP.) 2' (M A X . ) 4' (MIN.) 12" CURBLINE CURBLINE Painted Pavement Markings - On Site N.T.S.Source: VHB LD_554 1/16 LANE NOTES 1.PAVEMENT MARKINGS TO BE INSTALLED FOR ON SITE WORK IN LOCATIONS SHOWN. 4' 2' 4' 1' (TYP.) 2' (TYP.) 4" WHITE PAINT (TYP.) 17"10"17" 3'-8" WHITE PAINT3' - 0 " 3' - 0 " 6'- 0 " 4" 5'- 0 " 2'- 2 " 2'- 1 0 " 2'-0"3'-0" 4" WHITE PAINT 8'- 0 " 7'-9" 16 " 4" 4" WHITE PAINT 16 " (T Y P . ) 2' - 0 " 12 " LENGTH AS REQUIRED (SEE STRIPING PLAN) WHITE PAINTED STOP LINE NOTES 1.ALL SLOPES THROUGHOUT THE ACCESSIBLE PARKING AND AISLE AREAS SHALL NOT EXCEED 1.5%. 45° 5'(MIN.) OR AS SHOWN ON PLANS9'(MIN.) SEE DETAIL ACCESSIBLE PARKING SEE PLANS 4' 4' BLUE SKID- RESISTANT PAINT 3" WIDTH (PAINTED WHITE) 4" WIDTH (PAINTED WHITE) ACCESS AISLE 4" WHITE LINES 24" ON CENTER 4" WIDTH (PAINTED WHITE) DETAIL Accessible Parking Space N.T.S.Source: VHB LD_552W 1/16 Parking Sign Post - Type 'A' N.T.S.Source: VHB LD_701 1/16 *THIS DIMENSION SHALL BE A MAXIMUM OF 8' FOR ACCESSIBLE SIGNAGE. *THIS DIMENSION SHALL BE A MINIMUM OF 5' FOR ACCESSIBLE SIGNAGE. * 24" * 7' (MIN.) * * REV NOTE: TYPE A SIGN POST SHALL BE USED FOR HANNAFORD TO-GO AND ACCESSIBLE PARKING SPACE SIGNS Handicap Parking Sign, MUTCD R7-8 N.T.S.Source: VHB LD_ 6/18 RESERVED PARKING Dumpster Pad N.T.S.Source: VHB LD_710 1/16 NOTES 1.SIZE OF PAD TO BE AS INDICATED ON PLANS. 2.CONSTRUCTION JOINTS SHALL BE SPACED NO MORE THAN 30 FEET ON CENTER AND SHALL BE EQUALLY SPACED OVER THE LENGTH AND WIDTH OF THE PAD. 3.CONTRACTION JOINTS SHALL BE 1.5" DEPTH WITH MAXIMUM 12' SPACING. 12" 12"3" 6" REV Dumpster Pad w/ Enclosure N.T.S.Source: VHB LD_713 1/16 NOTES 1.REFER TO PLAN FOR ACTUAL DIMENSION. PLAN VIEW 11' (MIN.) 2'-0" 3" 15'(MIN.) 6" 6" Bollard Mounted Parking Sign - Type 'B' N.T.S.Source: VHB LD_703S 1/16 *THIS DIMENSION SHALL BE A MAXIMUM OF 8' FOR ACCESSIBLE SIGNAGE. *THIS DIMENSION SHALL BE A MINIMUM OF 5' FOR ACCESSIBLE SIGNAGE. * ** * 7' (MIN.) 1'-9" 3'-6" 4'-0" REV PEDESTRIAN SIGNAL NOTES 1.REFER TO STANDARD E-171A FOR TRAFFIC SIGNAL GENERAL NOTES. 2.STEEL PEDESTAL POSTS AND BASES SHALL BE PAINTED FEDERAL BLACK, AFTER GALVANIZATION. UNLESS OTHERWISE NOTED IN THE PLANS. ALUMINUM POSTS AND BASES SHALL BE PAINTED BLACK. 3.ALL PEDESTAL POLES WHICH ARE PROVIDED WITH A BREAKAWAY FEATURE SHALL CONFORM TO THE REQUIREMENTS OF THE AASHTO 1985 STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINARIES, AND TRAFFIC SIGNALS, SECTION 7 AND SUBSEQUENT REVISIONS. 4.REFER TO STD E-171C FOR PEDESTRIAN PUSH BUTTON ACCESSIBILITY DETAILS. 5.PUSH BUTTON CONTROLS SHALL BE RAISED FROM OR FLUSH WITH THEIR HOUSINGS AND SHALL BE A MINIMUM OF 2' IN THE SMALLEST DIMENSIONS. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 lbf. 6.SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL BY ENGINEER AND DEPARTMENT OF PUBLIC WORKS PRIOR TO ORDERING. 7.CONTRACTOR TO PROVIDE CONCRETE BASE IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS. 3'-6" 7' - 10' MINIMUM MOUNTING HEIGHT FOR AUDIO SIGNAL IS 8' PEDESTRIAN ASSEMBLY TO INCLUDE AUDIO SIGNALS Traffic Control Signals Pedestal Post Mounted N.T.S.Source: VTRANS STD_E-170 11/99 PEDESTAL POLE INSTALLATION Wood Guardrail N.T.S.Source: VHB LD_450 10/20 2'-7" 4" 7'-0" 2'-0"3'-8" 4'-0" O.C. 6" 8" REV 12" COMPACTED SUBGRADE ROADWAY GEOTEXTILE MIRAFI 500X OR APPROVED EQUAL 16" OR 12" DIA. CONCRETE SUPPORT LANDSCAPED AREA 2 12" DIA. STEEL POST (PAINT COLOR SELECTED BY ARCHITECT) TYPICAL SIGN CAP STEEL PIPE POST COMPACTED SUBGRADE COMPACTED GRAVEL VTRANS 704.05A 4000 PSI CEMENT CONCRETE (TYPE II) 6%(1.5%±) AIR ENTRAINED #4 @ 16" BOTH WAYS (CENTERED) BITUMINOUS CONCRETE PAVEMENT APPROACH APRON DOUBLE DOORS SCORE LINE (TYP.) 6" CONCRETE PAD PROPOSED ENCLOSURE BY OTHERS. COORDINATE WITH OWNER. 6" COMPACTED GRAVEL 24" DIA. CONCRETE ENCASEMENT (3000 PSI) FINISH GRADE SURFACE TREATMENT VARIES YELLOW PLASTIC COVER 6" DIA. STEEL PIPE FILLED WITH CONCRETE 2 12" DIA. STEEL POST TYPICAL SIGN CAP STEEL PIPE POST AUDIO SIGNAL REINFORCEMENT PLATE PEDESTAL ADAPTER SET SCREWS STANDARD 4" PIPE POLE 4 1/2" O.D. 9"x12" PEDESTRIAN INSTRUCTION SIGN SEE STD. E-140 PEDESTRIAN PUSH BUTTON MOUNTING SADDLE, PUSH BUTTON AND SIGN TO BE ORIENTED AS SHOWN ON THE PLAN OR AS DIRECTED BY THE ENGINEER. FINISHED SURFACE CURB 4"X10" WOOD RAIL 6"X8" WOOD POSTS @ 4'-0" O.C. BUTT JOINT (TYP.) 2- 58" GALVANIZED CARRIAGE BOLTS PER POST PER RAIL 2-58" GALVANIZED CARRIAGE BOLTS PER POST PER RAIL 6" 3" 6" STEEL BOLLARD 6" COMPACTED GRAVEL, 704.05A of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Site Details 2 C7.02 12 CHS PBS Issued for Construction 10/17/2022 PBS1 Typical Section - Stormtech SC 310 System N.T.S.Source: VHB LD_ 11/16 18" MIN*8' MAX 12" MIN 12" TYP 34" 6" MIN ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE (OR APPROVED EQUAL) ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS 16" *TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 24" (600 mm). EXISTING NATIVE SUBGRADE SC-310 END CAP PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) D C B A NOTE: 1.FOR ALL SYSTEMS INSTALL ISOLATOR ROW GEOTEXTILE IN ACCORDANCE WITH MANUFACTURERS GUIDANCE. INSTALL ISOLATOR ROWS AS SHOWN ON SYSTEM PLAN VIEWS. 2.THE CONTRIBUTING DRAINAGE AREA TO EACH SYSTEM SHALL HAVE DENSE AND VIGOROUS VEGETATIVE COVER, AND SHALL RECEIVE FINAL STABILIZATION PRIOR TO ACCEPTING RUNOFF. STORMTECH SC-310 CHAMBER (TYP) Storm Drain Trench N.T.S.Source: VHB LD_ 1/16 1 1 NOTES 1.WHERE UTILITY TRENCHES ARE CONSTRUCTED THROUGH DETENTION BASIN BERMS OR OTHER SUCH SPECIAL SECTIONS, PLACE TRENCH BACKFILL WITH MATERIALS SIMILAR TO THE SPECIAL SECTION REQUIREMENTS. 2.BEDDING TO PROVIDE A FIRM, STABLE, CONTINUOUS, AND UNIFORM SUPPORT FOR THE FULL LENGTH OF THE PIPE. 3.NO MECHANICAL TAMPERS SHALL BE USED DIRECTLY OVER THE PIPE TO ENSURE PIPE IS NOT DAMAGED 4.WHERE COVER OVER TOP OF ROOF DRAIN PIPE IS LESS THAN 5', PIPE SHALL BE INSULATED WITH 2" OF EXTRUDED POLYSTYRENE INSULATION BOARD OF 4' MIN. WIDTH CENTERED ON PIPE. VERIFY FINAL INSULATION THICKNESS WITH ENGINEER PRIOR TO PLACEMENT. DE P T H V A R I E S 12" (MIN.) 6" (M I N . ) PI P E DI A . 12" CO M P A C T E D BE D D I N G 5' - 0 " M A X I M U M VA R I E S PAVED AREA SEE APPLICABLE PAVEMENT SECTION LANDSCAPED AREA NOTES 1.ALL SECTIONS SHALL BE DESIGNED FOR HS-20 LOADING. 2.PROVIDE FLEXIBLE WATERTIGHT BOOTED CONNECTION AT ALL PIPE PENETRATIONS 3.JOINT SEALANT BETWEEN PRECAST SECTIONS SHALL BE PREFORMED BUTYL RUBBER. 4.CATCH BASIN FRAME AND GRATE SHALL BE SET IN FULL MORTAR BED. ADJUST TO GRADE WITH PRECAST CONCRETE RISER RINGS, MAX 12" 8"24"8" 48" MIN. DIAMETER DIMS. VARIES CONCENTRIC CONE SECTION SEE ALTERNATIVE TOP SLAB RISER SECTION(S) AS REQUIRED MONOLITHIC BASE SECTION12" (TYP) 4' (MIN) 24" SQUARE OPENING (TYP) 48" MIN. DIAMETER 8" (MIN)12" Deep Sump Catch Basin (CB) N.T.S.Source: VHB LD_100 1/16 REV ALTERNATIVE TOP SLAB 12" Drain Manhole (DMH) N.T.S.Source: VHB LD_115 1/16 NOTES 1.ALL SECTIONS SHALL BE DESIGNED FOR HS-20 LOADING. DIAMETER OF STRUCTURES SHALL BE COORDINATED WITH PIPE CONFIGURATIONS. 2.COPOLYMER MANHOLE STEPS SHALL BE INSTALLED AT 12" O.C. FOR THE FULL DEPTH OF THE STRUCTURE. 3.PROVIDE FLEXIBLE WATERTIGHT BOOTED CONNECTION AT ALL PIPE PENETRATIONS. 4.JOINT SEALANT BETWEEN PRECAST SECTIONS SHALL BE PREFORMED BUTYL RUBBER. 5.DRAIN MANHOLE FRAME AND COVER SHALL BE SET IN FULL MORTAR BED. ADJUST TO GRADE WITH PRECAST CONCRETE RISER RINGS, MAX 12" 12" (TYP.) 12" (TYP.) RISER SECTION(S) AS REQ'D. 8"8" MONOLITHIC BASE SECTION ALTERNATE TOP SLAB ECCENTRIC CONE SECTION SEE ALTERNATE TOP SLAB 24" DIA. ACCESS 24" DIA. ACCESS 12" 48" DIA. (MIN.) 8" (MIN.) DIA. VARIES 48" DIA. (MIN.) REV 6" MIN. Stormtech 6" Inspection Port Detail N.T.S.Source: VHB LD_ 1/17 FINAL FILL: INITIAL FILL: ¹ ¹ EMBEDMENT STONE: ¹ FOUNDATION STONE: ¹ Acceptable Fill Materials: Stormtech Chamber Systems N.T.S.Source: VHB LD_ 11/16 Stormtech SC-310 - System #2 Schematic N.T.S.Source: VHB LD_ 12/16 SYSTEM LAYOUT 180 SC-310 30 SC-310 89'± 52'± ALTERNATIVE ECCENTRIC CONE SECTION ALTERNATIVE TOP SLAB 8"24"8" 48" MIN. DIAMETER DIMS. VARIES CONCENTRIC CONE SECTION SEE ALTERNATIVE TOP SLAB RISER SECTION(S) AS REQUIRED MONOLITHIC BASE SECTION12" (TYP) 2' (MIN) 12" 24" SQUARE OPENING (TYP) 48" MIN. DIAMETER 8" (MIN)12" Catch Basin (CB) N.T.S.Source: VHB LD_100 11/19 REV NOTES 1.ALL SECTIONS SHALL BE DESIGNED FOR HS-20 LOADING. 2.PROVIDE FLEXIBLE WATERTIGHT BOOTED CONNECTION AT ALL PIPE PENETRATIONS 3.JOINT SEALANT BETWEEN PRECAST SECTIONS SHALL BE PREFORMED BUTYL RUBBER. 4.CATCH BASIN FRAME AND GRATE SHALL BE SET IN FULL MORTAR BED. ADJUST TO GRADE WITH PRECAST CONCRETE RISER RINGS, MAX 12" COMPACTED BEDDING HAND TAMPED HAUNCHING DEPTH AND SURFACE TREATMENT VARIES COMPACTED SUBGRADE SAWCUT COMMON FILL/ ORDINARY BORROW SAND BLANKET, VAOT ITEM 703.03A 34" CRUSHED STONE, VAOT ITEM 704.02B FINISH GRADE SEE NOTE 4 OUTLET SEE NOTE 2. 34" CRUSHED STONE, VAOT 704.02B NOTE 3 COMPACTED SUBGRADE 34" CRUSHED STONE VAOT 704.02B COMPACTED SUBGRADE SEE NOTE 3. DIA. VAR I E S SEE NOTE 5. SEE NOTE 4. OUTLET FINISH GRADE STEPS, SEE NOTE 2. 9" MIN. FOR SYSTEM #1 12" MIN. FOR SYSTEM #2 OIL/DEBRIS TRAP FINISH GRADE SEE NOTE 4 NOTE 3 OUTLET SEE NOTE 2 COMPACTED SUBGRADE 34" CRUSHED STONE, VAOT 704.02B Flared End Section (FES) with Stone Protection N.T.S.Source: VHB LD_134 3/19 FILTER FABRIC COMPACTED SUBGRADE ENERGY DISSIPATION BOWL PIPE DIA. D APPROX. LIMITS OF ENERGY DISIPATION BOWL 12" 3D 8' 5' APRON EDGE TO BE SET LEVEL WITH FLARED END INVERT ELEVATION (TYP.) HDPE FLARED END SECTION SLOPE 1:1 (MAX.) VTRANS TYPE I STONE FINISH GRADE 18" 1' 3'3' SECTION A-A PLAN REV Infiltration Trench N.T.S.Source: VHB LD_181 12/19 18"PIPE DIA.18" 12" PIPE DIA. 2" 18" (MIN.) OVERLAP COMPACTED COMMON FILL TYPICAL PAVEMENT SECTION FINISH GRADE COMPACTED COMMON FILL SURFACE TREATMENT VARIES NATURAL GROUND OR PERVIOUS MATERIAL APPROVED BY GEOTECHNICAL ENGINEER 2" WASHED CRUSHED STONE FILTER FABRIC PAVED AREA LANDSCAPED AREA REV PERFORATED HIGH DENSITY POLYETHYLENE (HDPE) PIPE (REFER TO PLAN FOR SIZE, INVERT, AND LOCATION) of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Site Details 3 C7.03 13 SMW PBS Foundation Drain Outlet 12/06/2022 PBS1 4 Added Infiltration Trench Detail 06/08/2023 PBS2 Waterline Trench N.T.S.Source: VHB LD_ 1/16 1 1 NOTES 1.COMPACTION REQUIREMENTS: (STANDARD PROCTOR METHOD), 90% OF MAXIMUM DENSITY WHEN TRENCH EXCAVATION OCCURS ON A CROSS-COUNTRY ROUTE, 95% OF MAXIMUM DENSITY WHEN TRENCH EXCAVATION OCCURS IN TRAVELED WAYS COMPACTED IN 12" LIFTS. 2.USE METALLIC TRACING/WARNING TAPE OVER ALL PIPES. 3.BEDDING TO PROVIDE A FIRM, STABLE, CONTINUOUS, AND UNIFORM SUPPORT FOR THE FULL LENGTH OF THE PIPE. 4.NO MECHANICAL TAMPERS SHALL BE USED DIRECTLY OVER THE PIPE TO ENSURE PIPE IS NOT DAMAGED 5.FOUR-INCH (4") AND SIX-INCH (6") DI PIPE SHALL HAVE NO LESS THAN TWO (2) BRONZE WEDGES INSTALLED AT EACH JOINT. EIGHT-INCH (8") AND LARGER DI PIPE SHALL HAVE NO LESS THAN THREE (3) BRONZE WEDGES INSTALLED AT EACH PIPE JOINT. 6.ALL WATER LINES AND APPURTENANCES SHALL BE INSTALLED IN ACCORDANCE WITH THE CHAMPLAIN WATER DISTRICT SPECIFICATIONS AND DETAILS FOR THE INSTALLATION OF WATER LINES AND APPURTENANCES, CURRENT EDITION. DEPTH VARIES 12" (MIN.) 12" (MIN.) PIPE DIA. 12" 6'-0" MINIMUM COMPACTED BEDDING PAVED AREA SEE APPLICABLE PAVEMENT SECTION LANDSCAPED AREA WATER & SANITARY UTILITY CROSSINGS PARALLEL INSTALLATION 18"(MIN.) 10'-0" (MIN.) Water/Sewer Separation N.T.S.Source: VHB LD 1/16Concrete Thrust Block N.T.S.Source: VHB LD_260 1/16 1 1 NOTES 1.PROVIDE BLOCKS FOR TAPPING SLEEVES, DEAD ENDS, GATE VALVES, AND VERTICAL BENDS (SAME SIZE AS REQUIRED FOR TEES). PROVIDE ANCHOR RODS AT VERTICAL BENDS AND GATE VALVES. 2.CONCRETE SHALL NOT BE PLACED AGAINST PIPE BEYOND FITTING. 3.CONCRETE SHALL BE 3,000 PSI-TYPE I. 2 2G H I D E FC J B Plan SECTION 1-1 PLAN SECTION 2-2 TEES TABLE OF DIMENSIONS TEES G H I J TEES G H I J 6"X6"X6"12"24"24"18"12"X12"X6"12"24"24"18" 8"X8"X6"""""12"X12"X8""""24" 8"X8"X8""""24"12"X12"X12""36""36" TABLE OF DIMENSIONS BENDS B C D E F BENDS B C D E F 6" 11 14°8"15"12"24"12"6" 45°8"30"12"24"14" 6" 22 12°"19"""13"6" 90°"30"""27" 8" 11 14°"20"""12"8" 45°"30"""24" 8" 22 12°"22"""17"8" 90°"38"""36" 12" 11 14°"30"""15"12" 45°"40"""40" 12" 22 12°"35"""25"12" 90°"60"""52" BENDS Sewerline Trench N.T.S.Source: VHB LD_ 1/16 11 NOTES 1.WHERE UTILITY TRENCHES ARE CONSTRUCTED THROUGH DETENTION BASIN BERMS OR OTHER SUCH SPECIAL SECTIONS, PLACE TRENCH BACKFILL WITH MATERIALS SIMILAR TO THE SPECIAL SECTION REQUIREMENTS. 2.USE METALLIC TRACING/WARNING TAPE OVER ALL PIPES. 3.BEDDING TO PROVIDE A FIRM, STABLE, CONTINUOUS, AND UNIFORM SUPPORT FOR THE FULL LENGTH OF THE PIPE. 4.NO MECHANICAL TAMPERS SHALL BE USED DIRECTLY OVER THE PIPE TO ENSURE PIPE IS NOT DAMAGED DEPTH VARIES 12" (MIN.) 6" (MIN.) PIPE DIA. 12" COMPACTED BEDDING 5'-0" MAXIMUM VARIES PAVED AREA SEE APPLICABLE PAVEMENT SECTION LANDSCAPED AREA Cleanout - Paved Area N.T.S.Source: VHB LD_303 1/16 FLOW SEE PLANS FOR INVERT AND PIPE SIZE 45°PVC BEND AT END OF LINE WYE CONNECTION FOR IN-LINE 12" 6" PVC CONCRETE COLLAR 6"THREADED PLUG RING & COVER FINISH GRADE AT PAVEMENT Sanitary Sewer Manhole (SMH) N.T.S.Source: VHB LD_200-VT 1/16 NOTES 1.STRUCTURES SHALL BE PRECAST CONCRETE, DESIGNED FOR HS-20 LOADING. 2.POLYPROPYLENE "DROP-FRONT" MANHOLE STEPS, CAST IN PLACE, SHALL BE INSTALLED AT 12" O.C. FOR THE FULL DEPTH OF THE STRUCTURE. 3.EXTERIOR SURFACES SHALL BE GIVEN TWO COATS OF BITUMINOUS WATER- PROOFING MATERIAL. 4.JOINT SEALANT BETWEEN PRECAST SECTIONS SHALL BE A DOUBLE LAYER OF PREFORMED BUTYL RUBBER. 5.STANDARD SEWER MANHOLE FRAME AND COVER SHALL BE SET IN FULL MORTAR BED. ADJUST TO GRADE WITH MAX 12" PRECAST CONCRETE RISER RINGS. (STEEL REINFORCED FOR HS-20 LOADING) 12" MIN. DIA. VARIES12" (TYP.) MONOLITHIC BASE SECTION RISER SECTION(S) AS REQ'D. ECCENTRIC CONE SECTION SEE ALTERNATE TOP SLAB 48" DIA. MANHOLE (MIN.) 8" 30" DIA. ACCESS 8" 48" DIA. MANHOLE 12"8" 30" DIA. ACCESS ALTERNATE TOP SLAB Proposed Street Typical Cross Section N.T.S.Source: VHB LD_ 9/19 NOTES 1.CONDUITS SHALL BE CONCRETE ENCASED WHERE IDENTIFIED ON THE SITE PLANS, AND UNDER THE FOLLOWING CONDITIONS: 1.1.AT WATER CROSSINGS (I.E. BROOKS, STREAMS, ETC.) 1.2.AT CROSSING OF WATER, SEWER, AND GAS PIPELINES FOR 10 FEET ON EITHER SIDE. 1.3.WHEN UNDER THE TRAVELED WAY OF CITY STREETS, TOWN HIGHWAYS, DRIVEWAYS, ETC. 1.4.WHEN WITHIN 20 FEET OF TANKS CONTAINING FUEL OR SOLVENTS. 2.ALL TRENCHES AND ELECTRICAL CONDUITS SHALL BE APPROVED BY UTILITY INSPECTOR PRIOR TO BACKFILLING OF TRENCHES. 3.ALL TRENCHES SHALL BE 18" MIN. WIDTH. BACKFILL OVER THE TRENCH SHALL BE CLEAN, FINE SAND OR GRAVEL THAT PASSES 1" SIEVE, AND COMPACTED IN LIFTS FOR THE FULL BURIAL DEPTH. 4.MOUNDING THE TRENCH IS NOT ALLOWED TO ACHIEVE BURIAL DEPTH. 5.ALL CONDUITS SHALL BE SCHEDULE 40 PVC. 6.PROVIDE 4" MIN. CONCRETE COVER TO OUTSIDE OF PIPE, BETWEEN ALL CONDUITS, AND BETWEEN CONDUITSAND SOIL. Concrete Encased Electrical Trench N.T.S.Source: VHB LD_VT 2/20 T/C T/C T/CT/C E E 4" MIN 12" MIN 4" MIN 3,000 PSI CONCRETE ENCASEMENT 40" MIN BURY DEPTH 4" DIA. TELEPHONE AND CABLE CONDUITS 5" DIA. ELECTRICAL CONDUITS 4" MIN NOTES 1.ALL FITTINGS ARE TO HAVE WEDGE STYLE RETAINER GLANDS. 2.PRIOR TO POURING THRUST BLOCKS ALL FITTINGS ARE TO BE WRAPPED WITH 4mil. POLYETHYLENE. 3.THE ABOVE OWNERSHIP LINE REFERENCES HYDRANTS ON CWD TRANSMISSION MAINS. REFER TO SPECIFICATIONS FOR MORE INFORMATION. 6' 15" - 21"2" - 6" Hydrant Assembly N.T.S.Source: CWD A-16 6/19 Oil/Water Separator N.T.S.Source: VHB LD_101 1/16 INVERT NOTES 1.ALL SECTIONS SHALL BE DESIGNED FOR HS-20 LOADING. 2.PROVIDE OPENINGS FOR PIPES WITH 2" MAX. CLEARANCE TO OUTSIDE OF PIPE. ALL PIPE SHALL BE CAST IN PLACE NITRILE RUBBER BOOT CONNECTIONS. 3.JOINT SEALANT BETWEEN PRECAST SECTIONS SHALL BE PREFORMED BUTYL RUBBER. 4.MANHOLE FRAME AND COVER SHALL BE SET IN FULL MORTAR BED. ADJUST TO GRADE WITH PRECAST RISER RINGS, 12" MAX. DIA. VARIES 12" (TYP.) MONOLITHIC BASE SECTION RISER SECTION(S) AS REQD. CONCENTRIC CONE SECTION SEE ALTERNATE TOP SLAB 4' (MIN.) 48" DIA. (MIN.) ALTERNATE TOP SLAB 48" DIA. (MIN.) 24" SQUARE OPENING (TYP.) 8" MIN.12" 12" 8"24"8" 24" (MIN.) Asphalt Multi-Use Path N.T.S.Source: VHB LD_ 6/18 12"8' REV 12" Light Pole Foundation Detail (Up to 25' Pole) N.T.S.Source: VHB LD_310 1/16 BOLT LAYOUT & MOUNTING PROCEDURE AS PER MFG. SPECS #5 REBAR #3 REBAR CONDUIT AND GROUND ROD CONNECT TO INSIDE METAL POLE SEE ELECTRICAL PLAN FOR SIZE 5000 PSI TYPE II CONCRETE CEMENT 2" TYP. COVER FINISH GRADE (MATERIALS VARY) 4-#5 VERTICAL-EQ. SPACED #3 HORIZONTAL TIES @ 12" C.C. 1" CHAMFER LIGHT POLE & ANCHORING SYSTEM BY MFG. 2'-0" (MIN.) 6' - 0 " 2' - 6 " W I T H I N V E H I C L E A R E A S 0'- 6 " I N L A N D S C A P E A R E A S PROVIDE BASE COVER AS FURNISHED BY POLE MFG. COMPACTED OR UNDISTURBED SUBGRADE SECTION PLAN 24 " ( M I N . ) Light Pole Foundation Detail (Up to 15' Pole) N.T.S.Source: VHB LD_310A 1/16 BOLT LAYOUT & MOUNTING PROCEDURE AS PER MFG. SPECS #5 REBAR #3 REBAR CONDUIT AND GROUND ROD CONNECT TO INSIDE METAL POLE SEE ELECTRICAL PLAN FOR SIZE 5,000 PSI CONCRETE, TYPE II CEMENT 2'-0" (MIN.) COMPACTED OR UNDISTURBED SUBGRADE SECTION PLAN 2" TYP. COVER FINISH GRADE (MATERIALS VARY) 4-#5 VERTICAL-EQ. SPACED #3 HORIZONTAL TIES @ 12" C.C. 1" CHAMFER LIGHT POLE & ANCHORING SYSTEM BY MFG. 2" COVER ON REBAR 4' - 0 " 2' - 6 " W I T H I N V E H I C L E A R E A S 0'- 6 " I N L A N D S C A P E A R E A S 24 " (M I N . ) PROVIDE BASE COVER AS FURNISHED BY POLE MFG. STREET CROSS SECTION NOTES: 1.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY PUBLIC WORKS SPECIFICATIONS, THE VERMONT STATE STANDARD SPECIFICATIONS FOR CONSTRUCTION, AND THE APPROVED ENGINEERING PLANS AND SPECIFICATIONS. 2.EMULSION WILL BE PLACED ON THE FACE OF THE CURB WHERE IT WILL BE IN CONTACT WITH THE PAVEMENT. 3.EMULSION WILL BE PLACED BETWEEN THE BASE AND FINISH COATS OF PAVEMENT WHEN THE FINISH COURSE IS NOT PLACED IMMEDIATELY AFTER THE BASE COURSE PLACEMENT. ℄ 1 1 WIDTH VARIES (5' MIN) WIDTH VARIES TURNING LANE / ON-STREET PARKING 11' TRAVEL LANE 11' TRAVEL LANE 15 " R.O.W. WIDTH VARIES 1' SHOULDER WHERE SHOWN ON PLANS COMPACTED BEDDING HAND TAMPED HAUNCHING WARNING TAPE DEPTH AND SURFACE TREATMENT VARIES UNDISTURBED SUBGRADE SAWCUT COMPACTED GRANULAR FILL COMMON FILL/ ORDINARY BORROW, SEE NOTE 1 SAND BLANKET, VAOT ITEM 703.03A 34" CRUSHED STONE, VAOT ITEM 704.02B IN WET AREAS. SAND BLANKET VAOT ITEM 703.3A ELSEWHERE. AS DETERMINED BY THE ENGINEER WHERE SEWER CROSSES OVER WATER, PLACE THE CENTER OF BOTH PIPES AT CROSSING PIPE AND ENCASE THE TWO SEWER PIPE JOINTS NEAREST THE CROSSING IN CONCRETE OR THE SEWER PIPE SHALL BE WATER PRESSURE PIPE MATERIAL, OR EQUAL AND SHALL BE PRESSURE TESTED TO ENSURE WATER TIGHTNESS SEWER MAIN OR LATERAL WATER MAIN OR SERVICE WATER MAIN OR SERVICE CENTER A FULL LENGTH/STICK OF SEWER PIPE WHERE WATER MAIN CROSSING OCCURS. UNDISTURBED SOIL UNDISTURBED SOIL COMPACTED BEDDING HAND TAMPED HAUNCHING WARNING TAPE DEPTH AND SURFACE TREATMENT VARIES UNDISTURBED SUBGRADE SAWCUT COMPACTED GRANULAR FILL COMMON FILL/ ORDINARY BORROW SAND BLANKET, VAOT ITEM 703.03A 34" CRUSHED STONE, VAOT ITEM 704.02B COMPACTED SUBGRADE 3/4" CRUSHED STONE, VAOT 704.02B FORMED CONCRETE SHELF AND INVERT. SHELF SLOPED TOWARDS INVERT AT SLOPE OF 1"/FOOT OUTLET FLEXIBLE WATERTIGHT NITRILE GASKET OR SLEEVE SEE NOTE 4. SEE NOTE 3. STEPS, SEE NOTE2. SEE NOTE 5. FINISH GRADE ANCHOR TEE OR TEE W/ FOSTER ADAPTER THRUST BLOCK 3/4" CRUSHED STONE MINIMUM 12" THICK 6" DI PIPE W/ MEGA-LUG GLANDS THRUST BLOCK UNDISTURBED EARTH PAVING RISER IN ROADWAYS ADJUSTABLE IRON VAVLE BOX W/ COVER MARKED "WATER" PRECAST CONCRETE BLOCK W/ 8 SF BEARING SURFACE IS ACCEPTABLE PLUG HYDRANT DRAIN 6" M.J. RESILIENT WEDGE GATE VALVE 6" DI CL52 GRADE BREAKAWAY FLANGE FIRE HYDRANT (PER SPECS.) HYDRANT FLAG 4' GALVANIZED SPRING FLAG W/ REFLECTIVE BANDS CI T Y O W N E D MU N I C I P A L I T Y O W N E D COMPACTED GRAVEL COMPACTED SUBGRADE SEE NOTE OUTLET SEE NOTE 3. OIL/DEBRIS TRAP SEE NOTE 4. FINISH GRADE COMPACTED SUBGRADE 3" BITUMINOUS ASPHALT PAVEMENT 1.5" TYPE III 1.5" TYPE II 18" COMPACTED GRAVEL VTRANS 704.05A FINE ROADWAY GEOTEXTILE MIRAFI 500X OR APPROVED EQUAL 2" BITUMINOUS CONCRETE PAVEMENT - TYPE III 3" BITUMINOUS CONCRETE PAVEMENT - TYPE II 6" THICK CONCRETE SIDEWALK MINIMUM 24" GEOTEXTILE OVERLAP CONCRETE CURB (TYP. SEE DETAIL) STA: 100+00 - 101+40 S=1/3"/FT STA: 101+40 - 102+55 S=1/4"/FT MULTI-USE PATH 6" TOPSOIL AND SEED S=2% GEOTEXTILE FOR ROADBED SEPARATOR (MIRAFI 500X)24" VAOT 704.05A COARSE 6" VAOT 704.05B FINE 6" VAOT 704.05B FINE WIDTH VARIES (6' MIN) 1' SHOULDER WHERE SHOWN ON PLANS COMPACTED SUBGRADE REFER TO LA PLANS FOR PLANTING SOIL REQUIREMENTS IN ROW 1.25% 12" MIN WARNING TAPE 12" MIN COMPACTED BEDDING COMPACTED GRANULAR FILL DEPTH AND SURFACE TREATMENT VARIES STA: 100+00 - 101+40 S=1/3"/FT STA: 101+40 - 102+55 S=1/4"/FT Utility Trench N.T.S.Source: VHB LD_300 11/19 1 1 NOTES 1.USE METALLIC TRACING/WARNING TAPE OVER ALL PIPES. 2.COMPACTED GRANULAR FILL MAY CONSIST OF GRAVEL, CRUSHED STONE, SAND, OR OTHER MATERIAL AS APPROVED BY ENGINEER. 36" DEPTH COMPACTED BEDDING HAND TAMPED HAUNCHING WARNING TAPE MIN. 4" TOPSOIL COMPACTED SUBGRADE 12" (MIN.) 6" (MIN.) 12" COMPACTED BEDDING SAWCUT COMPACTED GRANULAR FILL COMMON FILL/ ORDINARY BORROW PAVED AREA SEE APPLICABLE PAVEMENT SECTION LANDSCAPED AREA REV 4" SPACING 4" SCH. 40 PVC CONDUIT (TYP.) of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 Site Details 4 C7.04 14 SMW PBS Revised Telecom, Storm Drain & Water Main 03/10/2023 DJH2 Revised Road Cross Slope 04/20/2023 DJH3 Added Utility Trench 08/08/2023 DJH4 General 1.CONTRACTOR SHALL NOTIFY "DIG-SAFE" (1-888-344-7233) AT LEAST 72 HOURS BEFORE EXCAVATING. 2.IN THE EVENT THAT SUSPECTED CONTAMINATED SOIL, GROUNDWATER, AND OTHER MEDIA ARE ENCOUNTERED DURING EXCAVATION AND CONSTRUCTION ACTIVITIES BASED ON VISUAL, OLFACTORY, OR OTHER EVIDENCE, THE CONTRACTOR SHALL STOP WORK IN THE VICINITY OF THE SUSPECT MATERIAL TO AVOID FURTHER SPREADING OF THE MATERIAL, AND SHALL NOTIFY THE OWNER IMMEDIATELY SO THAT THE APPROPRIATE TESTING AND SUBSEQUENT ACTION CAN BE TAKEN. 3.DAMAGE RESULTING FROM CONSTRUCTION LOADS SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO OWNER. Erosion Control 1.CONTRACTOR ACTIVITIES SHALL ADHERE TO THIS SITE PLAN SET, THE CONDITIONS OF THE CONSTRUCTION GENERAL PERMIT ISSUED FOR THIS PROJECT (DEC PERMIT #8311-9020.1), THE VERMONT EROSION PREVENTION AND SEDIMENT CONTROL FIELD GUIDE (2006), AND THE LOW RISK SITE HANDBOOK FOR EROSION PREVENTION AND SEDIMENT CONTROL. 2.THE TOTAL AUTHORIZED EARTH DISTURBANCE IS 4.18 ACRES. 3.NO MORE THAN 2 ACRES OF LAND MAY BE DISTURBED AT ANY ONE TIME. 4.EPSC MEASURES SHALL BE INSTALLED PRIOR TO EARTH DISTURBING ACTIVITIES WITH THE EXCEPTION OF LAND DISTURBANCE THAT MAY RESULT FROM ACCESSING THE AREA(S) WITH EQUIPMENT IN ORDER TO INSTALL THOSE EPSC MEASURES. TEMPORARY EPSC MEASURES INTENDED TO TRAP SEDIMENT SHALL BE INSTALLED AS A FIRST STEP IN LAND DISTURBING ACTIVITIES AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE, WITH THE EXCEPTION OF THOSE LAND DISTURBING ACTIVITIES THAT ARE NECESSARY TO INSTALL MEASURES. 5.PROPOSED CHANGES TO THE EPSC PLAN SHALL BE APPROVED BY THE PERMITTEE OR HIS/HER DESIGNEE PRIOR TO IMPLEMENTATION. 6.PERMISSION MUST BE GRANTED BY VT DEC PRIOR TO USE OF ANY SUPPORT ACTIVITIES OCCURRING OUTSIDE OF THE APPROVED PROJECT BOUNDARIES. THIS INCLUDES USE OF OFF-SITE WASTE AND BORROW AREAS. 7.ALL PARTIES ASSOCIATED WITH CONSTRUCTION ACTIVITIES WHO MEET EITHER OF THE FOLLOWING TWO CRITERIA OF "PRINCIPAL OPERATOR"' MUST OBTAIN COVERAGE UNDER THE CONSTRUCTION STORMWATER DISCHARGE PERMIT FOR THE PROJECT PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITIES BY THAT OPERATOR: a.THE PARTY HAS OPERATIONAL CONTROL OVER CONSTRUCTION PLANS AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO THE ABILITY TO MAKE MODIFICATIONS TO THOSE PLANS AND SPECIFICATIONS; OR b.THE PARTY HAS CONTINUOUS DAY-TO-DAY OPERATIONAL CONTROL OF THOSE ACTIVITIES AT THE PROJECT THAT ARE NECESSARY TO ENSURE COMPLIANCE WITH AN EPSC PLAN FOR THE SITE OR OTHER PERMIT CONDITIONS (E.G., THEY ARE AUTHORIZED TO DIRECT WORKERS AT A SITE TO CARRY OUT ACTIVITIES REQUIRED BY THE EPSC PLAN OR COMPLY WITH OTHER PERMIT CONDITIONS). Construction EPSC Notes: 1.EXISTING VEGETATION SHALL BE PROTECTED AND MAINTAINED TO THE EXTENT PRACTICABLE. 2.A VEGETATED BUFFER SHALL BE MAINTAINED FOR WATER RESOURCES (E.G., WETLANDS AND STREAMS) TO THE EXTENT PRACTICABLE. 3.TO THE EXTENT PRACTICABLE, SURFACE FLOW SHALL BE DIVERTED AWAY FROM EXPOSED SOILS AND WATER RESOURCES. CONTRACTOR SHALL CONTROL STORMWATER RUNOFF DURING CONSTRUCTION TO PREVENT ADVERSE IMPACTS TO OFF SITE AREAS, AND SHALL BE RESPONSIBLE TO REPAIR RESULTING DAMAGES, IF ANY, AT NO COST TO OWNER. 4.RESOURCE AREAS (E.G. STREAMS) WITHIN THE PROJECT AREA SHALL BE FLAGGED PRIOR TO ANY CONSTRUCTION RELATED ACTIVITIES OCCURRING WITHIN CLOSE PROXIMITY TO THOSE AREAS. 5.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH A SEDIMENT TRAPPING DEVICE AND DISCHARGED IN A MANNER THAT DOES NOT RESULT IN IMPACTS TO WATER QUALITY OR CONTRIBUTE TO EROSION. SEE DETAILS FOR MORE INFORMATION. 6.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO THE OTHER APPLICABLE CRITERIA: a.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. b.EXCAVATED MATERIAL SHALL BE PLACED IN UPLAND AREAS ON THE UPHILL SIDE OF THE TRENCHES, WHERE FEASIBLE. 7.SEDIMENT REMOVED FROM SEDIMENT CONTROL PRACTICES SHALL BE DISPOSED OF IN AN UPLAND AREA WITH STABILIZATION FOLLOWING DISPOSAL OF MATERIAL. 8.IN ADVANCE OF FORECASTED RAINFALL OR SNOWMELT, EPSC MEASURES THAT ARE LOCATED IN AREAS OF ACTIVE EARTH DISTURBANCE SHALL BE INSPECTED AND REPAIRED, AS NEEDED. 9.CONTRACTOR SHALL PREVENT DUST, SEDIMENT, AND DEBRIS FROM EXITING THE SITE AND SHALL BE RESPONSIBLE FOR CLEANUP, REPAIRS AND CORRECTIVE ACTION IF SUCH OCCURS. DUST CONTROL SHALL BE HANDLED VIA WATER OR CALCIUM CHLORIDE APPLICATION TO ROADWAYS AND OTHER AREAS WHERE DUST MAY BE GENERATED. 10.STABILIZED CONSTRUCTION ENTRANCES SHALL BE REGULARLY MAINTAINED TO CONTROL EQUIPMENT AND VEHICLES FROM TRACKING MATERIAL OFF SITE. 11.PERIMETER CONTROLS (E.G., SILT FENCE) SHALL BE INSTALLED ON THE DOWNSLOPE SIDE OF AREAS WHERE THERE IS POTENTIAL FOR SOIL EROSION AND/OR SEDIMENT RUNOFF. IN SOME AREAS WHERE THE GROUND SURFACE IS LEVEL AND THERE ARE NO PATHWAYS (E.G., DITCHES OR RUTS) THAT COULD TRANSPORT RUNOFF FROM THE PROJECT AREA, INSTALLATION OF PERIMETER CONTROLS MAY NOT BE NECESSARY PER APPROVAL BY THE ON-SITE PLAN COORDINATOR (OSPC). 12.STUMPING AND GRUBBING ACTIVITIES SHALL BE CONDUCTED IN ACCORDANCE WITH THE PROJECTS CONSTRUCTION STORMWATER DISCHARGE PERMIT AND EPSC PLAN. 13.CONSTRUCTION DEMARCATION AND PERIMETER CONTROLS SHALL COMPLY WITH THE FOLLOWING: CONSTRUCTION DEMARCATION: a.CONSTRUCTION DEMARCATION TO BE INSTALLED ALONG PERIMETER OF LIMITS OF DISTURBANCE PER THE EPSC PLANS b.WITHIN 50 FEET OF RESOURCE AREA, DEMARCATION MUST INCLUDE: ·2 TO 3 ROWS OF STAKED (OR STAPLED) 3-INCH (MIN.) ORANGE BARRIER MESH TAPE OR, ·ORANGE CONSTRUCTION FENCE, OR ·ORANGE SNOW FENCE c.WHEN GREATER THAN 50 FEET FROM A WATER RESOURCE AREA, DEMARCATION MAY INCLUDE: ·ONE ROW OF STAKED (OR STAPLED)3-INCH (MIN.) ORANGE BARRIER MESH TAPE OR, ·ORANGE CONSTRUCTION FENCE, OR ·ORANGE SNOW FENCE PERIMETER CONTROLS: a.PERIMETER CONTROLS ARE TO BE INSTALLED ON THE DOWNSLOPE SIDE OF AREAS OF DISTURBANCE WHERE THERE IS POTENTIAL FOR SEDIMENT RUNOFF AND/OR SOIL EROSION. b.PERIMETER CONTROLS ARE NOT TO CROSS ACTIVE ACCESS ROUTES OR PERENNIAL FLOW PATHS (E.G. A STREAM). c.PARTICULAR CARE IS TO BE TAKEN WHEN INSTALLING PERIMETER CONTROLS IN A WETLAND. d.WITHIN 50 FEET OF A WATER RESOURCE AREA, PERIMETER CONTROLS MUST INCLUDE: ·REINFORCED SILT FENCE - TO BE REINFORCED WITH WIRE MESH, STAKED HAYBALES, OR STAKED FIBER ROLLS. e.WHEN GREATER THAN 50 FEET FROM A WATER RESOURCE AREA, PERIMETER CONTROLS MAY INCLUDE: ·SILT FENCE (NON-REINFORCED), OR ·STAKED FIBER ROLLS, 15.AREAS OUTSIDE THE LIMITS OF PROPOSED WORK DISTURBED BY THE CONTRACTOR'S OPERATIONS SHALL BE RESTORED BY THE CONTRACTOR TO THEIR ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE. 16.PROJECT DEMARCATION OF AN AREA SHALL BE INSTALLED PRIOR TO EARTH DISTURBING ACTIVITIES WITHIN THAT ARE. AN EXCEPTION IS LAND DISTURBANCE THAT MAY BE NEEDED TO ACCESS THE AREA WITH EQUIPMENT IN OR TO INSTALL THE EPSC MEASURES. 17.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH A SEDIMENT TRAPPING DEVICE AND DISCHARGED IN A MANNER THAT DOES NOT RESULT IN IMPACTS TO WATER QUALITY OR CONTRIBUTE TO EROSION. Pre-construction and Permitting Notes: 1.THE NAME AND DAYTIME PHONE NUMBER OF THE OSPC SHALL BE PROVIDED IN WRITING TO VT DEC PRIOR TO THE START OF CONSTRUCTION. 2.THE NOTICE OF AUTHORIZATION (NOA) ISSUED BY VT DEC SHALL BE POSTED IN A LOCATION THAT IS VISIBLE TO THE PUBLIC (E.G., NEAR THE CONSTRUCTION ENTRANCE). 3.A COPY OF THE EPSC PLAN SHALL BE MAINTAINED ON-SITE DURING NORMAL WORKING HOURS FROM THE DATE OF COMMENCEMENT OF CONSTRUCTION ACTIVITIES TO THE DATE OF FINAL STABILIZATION. THE EPSC PLAN SHALL BE MADE AVAILABLE TO VT DEC UPON REQUEST. Winter Construction Notes: 1.WINTER CONSTRUCTION SEASON IS DEFINED BY VT DEC AS OCTOBER 15 TO APRIL 15. 2.THE FOLLOWING WINTER CONSTRUCTION CONDITIONS APPLY TO THOSE CONSTRUCTION ACTIVITIES INVOLVING EARTH DISTURBANCE BETWEEN OCTOBER 15 AND APRIL 15: a.FOR AREAS STABILIZED BY VEGETATION, SEED SHALL BE APPLIED NO LATER THAN SEPTEMBER 15. b.MULCH SHALL BE APPLIED AT DOUBLE THE REGULAR CONSTRUCTION SEASON RATE OR ROUGHLY 2 INCHES OF MULCH WITH 80 TO 90% COVER (SEE MULCH DETAIL). MULCH SHALL BE TRACKED IN OR STABILIZED WITH NETTING. c.ENLARGE ACCESS POINTS AS PERMITTABLE TO PROVIDE SPACE FOR SNOW STOCKPILING.. d.LIMITS OF DISTURBANCE SHALL BE MOVED OR REPLACED TO REFLECT BOUNDARY OF WINTER WORK, AS NEEDED. e.CLEARED SNOW SHALL BE PLACED DOWN GRADIENT OF ALL AREAS OF DISTURBANCE WHERE FEASIBLE. f.SNOW SHALL NOT BE PLACED IN STORMWATER TREATMENT STRUCTURES. (E.G. BASINS) g.TO THE EXTENT PRACTICABLE, A MINIMUM 25-FOOT BUFFER FROM PERIMETER CONTROLS (E.G., SILT FENCE) SHALL BE MAINTAINED TO ALLOW FOR SNOW CLEARING AND MAINTENANCE. h.FOR AREAS OF DISTURBANCE WITHIN 100 FEET OF A RECEIVING WATER, SILT FENCE SHALL BE REINFORCED OR ELSE REPLACED WITH PERIMETER DIKES, SWALES, OR OTHER PRACTICES RESISTANT TO THE FORCES OF SNOW LOADS. i.DRAINAGE STRUCTURES ARE TO BE KEPT OPEN AND FREE OF SNOW AND ICE DAMS AS DETERMINED BY THE ON SITE PROJECT COORDINATOR. j.EPSC MEASURES THAT REQUIRE SOIL DISTURBANCE TO INSTALL (E.G., SILT FENCE) SHALL BE INSTALLED PRIOR TO GROUND FREEZING. k.SNOW AND ICE SHALL BE REMOVED TO LESS THAN 1 INCH THICKNESS PRIOR TO STABILIZATION. l.A 10 TO 20-FOOT WIDE STONE PAD SHALL BE USED IN AREAS WHERE CONSTRUCTION VEHICLE TRAFFIC IS ANTICIPATED (E.G., AROUND THE PERIMETER OF A BUILDING, WHERE APPLICABLE. m.TO ENSURE COVER OF DISTURBED SOIL IN ADVANCE OF A SNOWMELT EVENT, AREAS OF DISTURBED SOIL SHALL BE STABILIZED AT THE END OF EACH WORKDAY, UNLESS I.WORK IS TO CONTINUE WITHIN THE AREA WITHIN THE NEXT 24 HOURS AND THERE IS NO PRECIPITATION FORECAST OF THE NEXT 24 HOURS OR II.WORK IS OCCURRING IN A SELF-CONTAINED EXCAVATION (I.E., NO OUTLET) WITH A DEPTH OF 2 FEET OR GREATER (E.G., UTILITY TRENCHES). Temporary and Final Stabilization Notes: 1.DURING REGULAR CONSTRUCTION SEASON, ALL AREAS OF EARTH DISTURBANCE MUST BE STABILIZED WITHIN 14 DAYS OF INITIAL DISTURBANCE. AFTER THIS INITIAL 14-DAY PERIOD, ALL EARTH DISTURBANCE AREAS MUST BE STABILIZED ON A DAILY BASIS, WITH THE FOLLOWING EXCEPTIONS: a.STABILIZATION IS NOT REQUIRED IF WORK IS TO CONTINUE WITHIN THE AREA WITHIN THE NEXT 24 HOURS AND THERE IS NO PRECIPITATION FORECAST FOR THE NEXT 24 HOURS. b.STABILIZATION IS NOT REQUIRED IF THE WORK IS OCCURRING IN A SELF-CONTAINED EXCAVATION (I.E., NO OUTLET FOR STORMWATER) WITH A DEPTH OF 2 FEET OR GREATER (E.G., UNDERGROUND UTILITY INSTALLATION). 2.DURING "WINTER CONSTRUCTION," (OCTOBER 15 TO APRIL 15) DISTURBED SOIL MUST BE STABILIZED AT THE END OF EACH DAY, WITH THE FOLLOWING EXCEPTIONS: a.IF NO PRECIPITATION WITHIN 24 HOURS IS FORECAST AND WORK WILL RESUME IN THE SAME DISTURBED AREA WITHIN 24 HOURS, DAILY STABILIZATION IS NOT NECESSARY. b.STABILIZATION IS NOT REQUIRED IF THE WORK IS OCCURRING IN A SELF-CONTAINED EXCAVATION (I.E., NO OUTLET FOR STORMWATER) WITH A DEPTH OF 2 FEET OR GREATER (E.G., UNDERGROUND UTILITY INSTALLATION). 3.DISTURBANCE ACTIVITIES MUST BE COORDINATED TO ENSURE THAT THE ALLOWABLE CONCURRENT EARTH DISTURBANCE IS NOT EXCEEDED. THE MAXIMUM AREA OF EARTH DISTURBANCE THAT IS ALLOWED AT ANY ONE TIME IS 5.0 ACRES. 4.WORK IS TO PROCEED INCREMENTALLY, WITH STABILIZATION OCCURRING IMMEDIATELY FOLLOWING COMPLETION OF AN INDIVIDUAL AREA (E.G. ONE BUILDING PAD OR PARKING AREA) TEMPORARY SOIL STABILIZATION SHALL BE ACHIEVED BY MULCH, SEED AND MULCH, HYDROSEEDING WITH MULCH TACKIFIER, SOD, STONE, AND/OR ROLLED EROSION CONTROL PRODUCTS (E.G., EROSION CONTROL BLANKET). MULCH SHALL BE COMPRISED OF STRAW, HAY, COMPOST, WOOD CHIPS, WOOD STUMP GRINDINGS, AND/OR EROSION CONTROL MIX. 5.PERMANENT STABILIZATION SHALL BE ACHIEVED BY 70% VEGETATION COVER, STONE, ASPHALT, BEDROCK, OR OTHER PERMANENT MATERIAL THAT PROVIDES COMPLETE COVER OF EXPOSED SOILS. 6.AREAS THAT HAVE REACHED TEMPORARY OR FINAL STABILIZATION SHALL NOT BE CONSIDERED PART OF TOTAL AREA OF EARTH DISTURBANCE. 7.APPROPRIATE SEED MIX SHALL BE APPLIED TO DESIGNATED AREAS PER THE SEED DETAIL SPECIFICATIONS. FOR AN AREA TO BE STABILIZED FOR WINTER BY VEGETATED COVER, SEEDING MUST BE COMPLETED BY SEPTEMBER 15. 8.AREAS TO BE STABILIZED FOR WINTER THAT DO NOT HAVE ESTABLISHED VEGETATION BY OCTOBER 15 SHALL BE STABILIZED BY ANCHORED MULCH AT THE WINTER APPLICATION RATE, OR OTHER APPROVED STABILIZATION MEASURES (E.G., ROLLED EROSION CONTROL PRODUCT). DORMANT SEEDING WITH WINTER RYE IS RECOMMENDED. 9.ALL FINAL GRADE SLOPES STEEPER THAN 3H:1V SHALL BE STABILIZED WITH EROSION CONTROL MATTING, UNLESS SHOWN OTHERWISE ON THE SITE STABILIZATION PLAN. 10.ALL TEMPORARY EPSC MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY EPSC MEASURES ARE NO LONGER NEEDED. OSPC Inspection Requirements: 1.EPSC INSPECTION, MONITORING, AND REPORTING ARE REQUIRED PER THE CONDITIONS OF GENERAL PERMIT 3-9020 STIPULATIONS FOR MODERATE RISK SITES. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING AND MAINTAINING EROSION PREVENTION AND SEDIMENT CONTROLS THAT MINIMIZE OR ELIMINATE POLLUTANTS IN STORMWATER DISCHARGE. 2.INSPECTIONS BY THE ON-SITE PLAN COORDINATOR (OSPC) SHALL BE CONDUCTED AT LEAST ONCE EVERY SEVEN (7) CALENDAR DAYS, WITH ADDITIONAL INSPECTION FREQUENCY REQUIRED FOR RAIN EVENTS, WINTER CONSTRUCTION, AND VISIBLE DISCHARGES PER THE CONDITIONS OF PART 6 OF GENERAL PERMIT 3-9020. A WRITTEN REPORT SHALL BE COMPLETED FOR EACH INSPECTION AND SIGNED BY THE OSPC. ALL REPORTS ARE TO BE MAINTAINED ON SITE AND MADE AVAILABLE TO STATE DEC REPRESENTATIVES UPON REQUEST. SEE SECTION 6.2 (G) OF GENERAL PERMIT 3-9020 FOR INSPECTION REPORT REQUIREMENTS. 3.IF VISIBLY DISCOLORED STORMWATER RUNS OFF THE CONSTRUCTION SITE OR RUNS OFF THE CONSTRUCTION SITE AND DISCHARGES TO RECEIVING WATERS, THE CONTRACTOR SHALL TAKE IMMEDIATE CORRECTIVE ACTION TO CORRECT THE DISCHARGE, INCLUDING MAINTAINING EXISTING EPSC MEASURES, AND INSTALLING SUPPLEMENTAL EPSC MEASURES. 4.SEE PARTS 6, 6.2, AND 6.3 OF GENERAL PERMIT 3-9020 AT HTTP://WWW.VTWATERQUALITY.ORG/STORMWATER/DOCS/ CONSTRUCTION/SW_CGP_AMENDED_FINAL.PDF FOR MORE INFORMATION. On-Site Plan Coordinator (OPSC) Notes: 1.THE OSPC DESIGNATED TO THE PROJECT (AND HIS/HER DESIGNEE) SHALL: a.REVIEW VT DEC'S "ON-SITE PLAN COORDINATOR MANUAL", b.BE ON-SITE ON A DAILY BASIS (OR HAVE A DESIGNEE THAT IS ON SITE WHEN HE/SHE CANNOT BE), c.BE DIRECTLY RESPONSIBLE FOR ON-SITE IMPLEMENTATION OF THE EPSC PLAN, d.BE KNOWLEDGEABLE IN THE PRINCIPLES AND PRACTICES OF EPSC, e.POSSESS THE SKILLS TO ASSESS CONDITIONS AT THE CONSTRUCTION SITE THAT COULD IMPACT STORMWATER QUALITY, f.POSSESS THE SKILLS TO ASSESS THE EFFECTIVENESS OF EPSC MEASURES SELECTED TO CONTROL THE QUALITY OF STORMWATER DISCHARGES FROM CONSTRUCTION ACTIVITY, g.POSSESS THE SKILLS AND EQUIPMENT TO CONDUCT TURBIDITY MONITORING PURSUANT TO THE CONSTRUCTION STORMWATER DISCHARGE PERMIT, AND h.HAVE THE AUTHORITY TO STOP AND/OR MODIFY CONSTRUCTION ACTIVITIES AS NECESSARY TO COMPLY WITH THE EPSC PLAN AND THE CONSTRUCTION STORMWATER DISCHARGE PERMIT. 2.ALL PROPOSED CHANGES TO THE EPSC PLAN MUST BE APPROVED BY THE OSPC OR HIS/HER DESIGNEE, AND THE OWENER'S DESIGNATED REPRESENTATIVE, PRIOR TO IMPLEMENTATION. THE PLAN DESIGNER OR A CERTIFIED PROFESSIONAL IN EROSION AND SEDIMENT CONTROL (CPESC) PRIOR TO IMPLEMENTATION, AND BE CONSIDERED MINOR AMENDMENTS AS DEFINED IN THE OSPC HANDBOOK. ALL MINOR AMENDMENTS ARE TO BE RECORDED USING THE MINOR AMENDMENT RECORD FORM AND MARKED ON THE MASTER OSPC PLAN SET. ALL MODIFICATIONS THAT FALL OUTSIDE OF THE MINOR AMENDMENT DEFINITION MUST BE APPROVED BY VT-DEC. 3.DURING THE REGULAR CONSTRUCTION SEASON (APRIL 15 TO OCT 15), THE OSPC OR HIS/HER DESIGNEE SHALL CONDUCT INSPECTIONS AT LEAST ONCE EVERY SEVEN (7) CALENDAR DAYS AND WITHIN 24 HRS FOLLOWING A STORM EVENT RESULTING IN DISCHARGE OF STORMWATER FROM THE CONSTRUCTION SITE. 4.DURING THE WINTER CONSTRUCTION SEASON (OCT 15 TO APRIL 15), THE OSPC OR HIS/HER DESIGNEE SHALL CONDUCT INSPECTIONS ON A DAILY BASIS DURING ACTIVE EARTHWORK. 5.THE OSPC AND HIS/HER DESIGNEE(S) SHALL FOLLOW TURBIDITY MONITORING PROTOCOLS OUTLINED IN VT DEC'S “MONITORING OF TURBIDITY IN STORMWATER RUNOFF FROM CONSTRUCTION ACTIVITIES” MANUAL. 6.INSPECTIONS CONDUCTED BY THE OSPC OR HIS/HER DESIGNEE SHALL COVER ALL AREAS OF THE SITE THAT ARE BEING ACTIVELY DISTURBED BY CONSTRUCTION OR CONSTRUCTION-RELATED ACTIVITIES, INCLUDING AREAS THAT HAVE BEEN TEMPORARILY STABILIZED. 7.OSPC INSPECTIONS SHALL BE DOCUMENTED USING THE VT DEC INSPECTION REPORT FORM OR A VT DEC-ACCEPTED INSPECTION REPORT FORM. 8.OSPC INSPECTION REPORTS SHALL BE MAINTAINED ON-SITE FOR THE DURATION OF THE PROJECT AND MADE AVAILABLE TO VT DEC UPON REQUEST. EPSC Narrative: PROJECT DESCRIPTION THE EPSC PLAN HAS BEEN PREPARED USING GENERAL PERMIT 3-9020, PART 4.1(C) AND APPENDIX B OF THE GENERAL PERMIT 3-9020, AS GUIDANCE IN PREPARING THE NARRATIVE. THE FOLLOWING SECTIONS (1) THROUGH (13) ADDRESS REQUIRED EPSC PLAN NARRATIVE ELEMENTS IN THE ORDER THAT THEY ARE PRESENTED IN APPENDIX B OF GENERAL PERMIT 3-9020. 1.PROJECT TYPE AND DESCRIPTION THE PROPOSED PROJECT WILL INVOLVE ADAPTIVELY REUSING AND RENOVATING THE EXISTING STRUCTURE INCLUDING THE REMOVAL OF TWO APPENDAGES AT THE REAR OF THE BUILDING AND CONSTRUCTING A NEW LOADING DOCK WITH EXTERIOR TRUCK WELL. THE PARKING LOT AREA WILL BE REHABILITATED INCLUDING THE REDUCTION OF LOT COVERAGE, ADDITION OF SHADE TREES, AND ADDING STORMWATER MANAGEMENT SYSTEM FOR TREATMENT AND CONTROL OF RUNOFF LEAVING THE SITE. 2.MAJOR PROJECT COMPONENTS MAJOR PROJECT COMPONENTS INCLUDE: GRADING; ROAD AND PARKING REDEVELOPMENT; UTILITY AND STORMWATER MANAGEMENT SYSTEM INSTALLATION; BUILDING CONSTRUCTION; AND FINAL GRADING, STABILIZATION, AND CLEANUP. PROPOSED EARTH DISTURBANCE THAT RESULTS FROM CONSTRUCTION ACTIVITIES SHALL BE KEPT TO A MINIMUM, WITH EPSC MEASURES SHALL BE INSTALLED PER THE EPSC PLAN PRIOR TO UPSLOPE DISTURBANCE. 3.TOTAL EARTH DISTURBANCE THE TOTAL ALLOWABLE AREA OF DISTURBANCE ASSOCIATED WITH THE PROJECT IS 7.2 ACRES. CONSTRUCTION AND STABILIZATION SHALL BE CONDUCTED PURSUANT TO THE EPSC PLAN. OVERSIGHT OF CONSTRUCTION AND ON-SITE PLAN COORDINATOR (OSPC) AS DESCRIBED UNDER OSPC INSPECTION REQUIREMENTS. IN THE EVENT OF VISIBLY DISCOLORED DISCHARGE FROM THE SITE, THE OSPC SHALL FOLLOW PROTOCOLS PROVIDED BY VT DEC FOR EPSC MEASURE IMPLEMENTATION, AND REPORTING, AS REQUIRED PER THE PERMIT. 4.SEQUENCE OF MAJOR PROJECT COMPONENTS THE OVERALL SEQUENCE OF CONSTRUCTION WILL GENERALLY OCCUR AS FOLLOWS PER THE PERMITTED EPSC PLAN: a.INSTALLATION OF PROJECT DEMARCATION FLAGGING b.INSTALLATION OF CONSTRUCTION ENTRANCE AND PERIMETER CONTROLS c.INSTALLATION OF EPSC MEASURES IN WORK AREA(S) TO BE DISTURBED d.INSTALLATION OF UTILITIES e.SITE GRADING AND CONSTRUCTION OF ROADWAY AND PARKING AREAS SUB BASE MATERIALS f.INSTALLATION OF SIDEWALKS, CURBS, LIGHTING, AND LANDSCAPE COMPONENTS g.FINAL GRADING AND PLACEMENT OF ASPHALT BASE COURSE, INSTALLATION OF SIDEWALKS, CURBS, LIGHTING, AND LANDSCAPE COMPONENTS h.EARTHWORK ASSOCIATED WITH THE BUILDING RENNOVATION i.FINAL GRADING, STABILIZATION, AND SITE CLEANUP 5.MAXIMUM CONCURRENT EARTH DISTURBANCE THE TOTAL MAXIMUM ALLOWABLE CONCURRENT EARTH DISTURBANCE IS 5 ACRES, WHILE IMPLEMENTING THE PERMITTED EPSC PLAN TO MINIMIZE POTENTIAL FOR EROSION AND SEDIMENT TRANSPORT ASSOCIATED WITH OPEN AREAS. 6.VEGETATED BUFFERS VEGETATIVE BUFFERS ARE NOT PROPOSED TO BE UTILIZED TO SUPPLEMENT STRUCTURAL EPSC MEASURES. 7.DURATION OF EXPOSED SOILS THE TOTAL DURATION OF EXPOSED SOIL WILL BE 14 DAYS FROM INITIAL DISTURBANCE, WHILE IMPLEMENTING THE PERMITTED EPSC PLAN TO TEMPORARILY OR PERMANENTLY STABILIZE AREAS AS SOON AS PRACTICABLE. 8.RECEIVING WATERS THE PROJECT IS LOCATED WITHIN THE POTASH BROOK WATERSHED. 9.DRAINAGE AREAS AND SOIL TYPES RUNOFF FROM THE PROJECT LEAVES THE SITE AT TWO POINTS, ONE TO THE WEST OF THE BUILDINGS WHICH FLOWS WEST VIA CLOSED PIPE NETWORK TO OFFSITE STORMWATER TREATMENT PRACTICES OR DRAIN OFFSITE TO THE WEST VIA OVERLAND FLOW, AND ONE IN THE FRONT PARKING LOT WHICH FLOWS DIRECTLY TO POTASH BROOK VIA CLOSED PIPE NETWORK. THE ONLY REPORTABLE AREA (GREATER THAN .5 ACRE) IS THE FRONT PARKING LOT. THE FRONT PARKING LOT AREA CONSISTS OF DISTURBING BELGRADE AND ELDRIDGE SOILS (NATIVE) K=0.49 AND EXISTING GRAVEL SUBBASE OR IMPORTED GRANULAR BORROW WHICH WILL BE USED AS FILL IN AREAS OVER THE EXISTING PARKING LOT K=0.17. 10.STREAM CROSSINGS THERE ARE NO PLANNED STREAM CROSSINGS. 11.WETLAND IMPACTS THERE ARE NO PLANNED WETLAND IMPACTS. 12.OFF-SITE WASTE AND BORROW AREAS THE PROJECT IS EXPECTED TO NEED TO BE A FILL SITE AND TO IMPORT MATERIAL THAT IS ANTICIPATED TO BE SUPPLIED FROM EXISTING BORROW PITS AND WILL BE GRANULAR BORROW AND ENGINEERED FILL. 13.WINTER CONSTRUCTION EARTH DISTURBING ACTIVITIES ARE ANTICIPATED TO OCCUR DURING THE WINTER CONSTRUCTION SEASON (OCTOBER 15 TO APRIL 15). SPECIAL WINTER CONSTRUCTION EPSC NOTES HAVE BEEN INCLUDED IN THIS EPSC PLANSET. Post-Construction Soil Depth and Quality Requirements   THESE REQUIREMENTS APPLY TO ALL DISTURBED AREAS WITHIN THE LIMITS OF THE SITE WHICH ARE NOT COVERED BY AN IMPERVIOUS SURFACE, INCORPORATED INTO A STRUCTURAL STORMWATER TREATMENT PRACTICE, OR ENGINEERED AS STRUCTURAL FILL ONCE DEVELOPMENT IS COMPLETE AND HAVE FINISHED GRADE SLOPES LESS THAN 3:1. AREAS SUBJECT TO THIS REQUIREMENT HAVE BEEN DEPICTED APPROXIMATELY, HOWEVER ALL AREAS MEETING THE CRITERIA ABOVE SHALL MEET THESE REQUIREMENTS. ANY AREAS WHICH ARE INCIDENTALLY DISTURBED OR COMPACTED DURING CONSTRUCTION SHALL ALSO BE SUBJECT TO THESE REQUIREMENTS. A DENSE AND VIGOROUS VEGETATIVE COVER SHALL BE ESTABLISHED OVER TURF AREAS. AS AN ALTERNATIVE TO LEAVING EXISTING TOPSOIL IN PLACE WITHOUT DISTURBING OR COMPACTING IT, THERE ARE THREE METHODS THAT MAY BE USED TO SATISFY THESE REQUIREMENTS. 1.AMEND EXISTING TOPSOIL IN PLACE a.SCARIFY OR TILL SUBSOILS TO 4 INCHES OF DEPTH OR TO THE DEPTH NEEDED TO ACHIEVE A TOTAL DEPTH OF 8 INCHES OF UNCOMPACTED SOIL AFTER A CALCULATED AMOUNT OF AMENDMENT IS ADDED. b.AMEND THE SOIL TO MEET THE ORGANIC CONTENT REQUIREMENTS. ORGANIC MATERIAL MAY BE PLACED AT A PRE-APPROVED RATE OF 1 INCH WITH AN ORGANIC MATTER CONTENT OF 40-65% AND ROTOTILLED INTO 3 INCHES OF TOPSOIL OR AT A CALCULATED RATE ROTOTILLED INTO A DEPTH OF SOIL NEEDED TO ACHIEVE 4 INCHES OF SETTLED TOPSOIL AT 4% ORGANIC CONTENT. c.IF COMPOST IS USED, IT SHALL HAVE A C:N RATIO BELOW 25:1, AND SHALL MEET THE CONTAMINANT STANDARDS IN THE VERMONT SOLID WASTE MANAGEMENT RULE. 2.REMOVE AND STOCKPILE EXISTING TOPSOIL DURING GRADING a.TOPSOIL SHOULD BE STOCKPILED ON SITE IN A CONTROLLED AREA AT LEAST 50 FEET FROM SURFACE WATERS, WETLANDS, FLOODPLAINS, OR OTHER CRITICAL RESOURCE AREAS. b.SCARIFY OR TILL SUBGRADE TO A DEPTH OF 4 INCHES. EXCEPT FOR WITHIN THE DRIP LINE OF EXISTING TREES, THE ENTIRE SURFACE SHALL BE DISTURBED BY SCARIFICATION. c.STOCKPILED TOPSOIL SHALL ALSO BE AMENDED, IF NEEDED, TO MEET THE ORGANIC CONTENT REQUIREMENTS IDENTIFIED ABOVE. d.REPLACE STOCKPILED TOPSOIL PRIOR TO PLANTING AND RAKE TO LEVEL, REMOVING ANY SURFACE ROCKS LARGER THAN 2 INCHES IN DIAMETER. e.WATER OR ROLL SOILS IN TURF AREAS TO 85% OF MAXIMUM DRY DENSITY. 3.IMPORT TOPSOIL MIX OF SUFFICIENT ORGANIC CONTENT AND DEPTH a.SCARIFY OR TILL SUBGRADE TO A DEPTH OF 4 INCHES.  EXCEPT FOR WITHIN THE DRIP LINE OF EXISTING TREES, THE ENTIRE SURFACE SHALL BE DISTURBED BY SCARIFICATION. b.PLACE 4 INCHES OF IMPORTED TOPSOIL MIX THAT CONTAINS 4% ORGANIC MATTER.  SOILS USED IN THE MIX SHALL BE SAND OR SANDY LOAM AS DEFINED BY THE USDA. c.RAKE TO LEVEL, REMOVING ANY SURFACE ROCKS GREATER THAN 2 INCHES IN DIAMETER. d.WATER OR ROLL SOIL IN TURF AREAS TO 85% OF MAXIMUM DRY DENSITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING AND EXECUTING A PLAN FOR VERIFYING THAT THESE AREAS HAVE MET THIS STANDARD.  THIS PLAN SHOULD INCLUDE A MINIMUM OF 9 TEST HOLES PER ACRE OF AREA SUBJECT TO THIS STANDARD.  THESE TEST HOLES SHALL BE EXCAVATED TO 8 INCHES USING ONLY A SHOVEL DRIVEN SOLELY BY THE WEIGHT OF THE INSPECTOR AND SHALL BE A MINIMUM OF 50 FEET APART. STORMWATER PERMIT NOTES THIS PROJECT IS SUBJECT TO THE TERMS AND CONDITIONS OF THE AUTHORIZATION FROM THE STATE OF VERMONT TO DISCHARGE STORMWATER RUNOFF FROM IMPERVIOUS SURFACES. THE STORMWATER TREATMENT PRACTICES IDENTIFIED ON THIS PLAN MUST BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE CONDITIONS OF THE PERMIT. STORMWATER TREATMENT PRACTICE INSTALLATION & MAINTENANCE THE STORMWATER TREATMENT PRACTICES FOR THIS PROJECT INCLUDE THE SIMPLE DISCONNECTION AREAS, THE DISCONNECTION AREAS ARE VEGETATED AREAS WHERE STORMWATER RUNOFF IS TREATED VIA SHEET FLOW. THESE AREAS ARE SUBJECT TO THE SOIL DEPTH AND QUALITY STANDARD DESCRIBED ABOVE. INSTALLATION OF THESE AREAS SHALL INCLUDE THE DEVELOPMENT OF VIGOROUS VEGETATED COVER OVER THE ENTIRE AREA. MAINTENANCE OF THE DISCONNECTION AREAS SHOULD INCLUDE PERIODIC MOWING (APPROXIMATELY TWICE PER YEAR) AND THE REPAIR OF ANY EROSION OR RILLING. THEY SHOULD BE MAINTAINED IN A VEGETATED STATE AND CARE SHOULD BE TAKEN TO NOT DISTURB OR COMPACT THE SOIL IN THESE AREAS ONCE INSTALLED. of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 EPSC Narrative and Notes C8.00 15 SMW PBS Issued for Construction 10/17/2022 PBS1 Block and Gravel Drop Inlet Protection (Paved Areas) N.T.S.Source: VHB LD_676-VT 1/16 Dewatering Filter Bag N.T.S.Source: VHB LD_691 1/16 NOTE: LIMIT ONE DISCHARGE HOSE PER BAG FILTER BAG FILTER BAG NOTES 1.BAG TO BE USED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 2.CONTRACTOR MAY PROPOSE ALTERNATE DEWATERING SYSTEM FOR REVIEW AND APPROVAL CROSS-SECTION PLAN VIEW 4' ( M A X . ) 10' (MIN.) GROUND SURFACE FILTER FABRIC PUMP DISCHARGE HOSE HOSE CLAMP NON-WOVEN TEXTILE 13 ' ( M I N . ) 15' (MIN.) SET ON FILTER FABRIC HOSE CLAMP SECURE DISCHARGE HOSE PUMP DISCHARGE HOSE FLOW NOTES 1.FILTER SOCK SHALL BE FILTREXX SILTSOXX, OR APPROVED EQUAL. 2.FILTER SOCK SHALL BE ANCHORED WITH GRAVEL BAGS. 3.FILTER SOCK SHALL BE INSPECTED PERIODICALLY AND AFTER ALL STORM EVENTS, AND REPAIR OR REPLACEMENT SHALL BE PERFORMED PROMPTLY AS NEEDED. 4.IF NON BIODEGRADABLE NETTING IS USED THE NETTING SHALL BE COLLECTED AND DISPOSED OF OFFSITE. REV Project Demarcation - Barrier Mesh Tape or Rope N.T.S.Source: VHB LD_VT 08/16 4' ( M I N . ) GRADE STAKE (TYP) NOTES 1.BARRIER MESH TAPE OR ROPE SHALL BE INSTALLED ALONG THE PERIMETER OF THE PROJECT AREA TO DEMARCATE THE LIMIT OF DISTURBANCE. NO EARTHWORK OR STORAGE OF MATERIALS SHALL BE CONDUCTED BEYOND THIS LIMIT WITHOUT PRIOR APPROVAL FROM THE OSPC. 2.USE 3" ORANGE BARRIER MESH TAPE OR 1/2" YELLOW POLYPROPYLENE ROPE. 3.WITHIN 50' OF WATER RESOURCE AREAS, USE 2-3 ROWS OF TAPE OR ROPE. BEYOND 50' OF WATER RESOURCE AREAS USE 1 ROW OF TAPE OR ROPE. 4.TAPE OR ROPE MAY BE FASTENED TO STAKES, TREES, OR OTHER APPROPRIATE FIXED OBJECTS. 5.PROJECT DEMARCATION SHALL NOT CROSS ACTIVE ACCESS ROUTES (E.G. ROADS). PROJECT DEMARCATION MAY CROSS RESOURCES AREAS WITH EXCEPTION OF LARGER WATER BODIES WHERE IT IS NOT FEASIBLE OR ADVISABLE. 6.PROJECT DEMARCATION SHALL REMAIN IN PLACE AND BE MAINTAINED/REPLACED AS NEEDED UNTIL FINAL STABILIZATION IN THE AREA HAS BEEN ACHIEVED. Stabilized Construction Exit N.T.S.Source: VHB LD_682-VT 1/16 3'5:1 PLAN VIEW CROSS-SECTION 1 12" CRUSHED STONE FILTER FABRIC MOUNTABLE BERM EXISTING PAVEMENT 50' (MIN.)SITE 8" (MIN.) 25' (MIN.) 10' 10' EXISTENCE PAVEMENT 10' (MIN.) 50' (MIN.)SITE NOTES 1.AGGREGATE SIZE: USE A MATRIX OF 1 TO 4 INCH STONE, OR RECLAIMED OR RECYCLED CONCRETE EQUIVALENT. 2.LENGTH: NOT LESS THAN 50 FEET (EXCEPT ON SINGLE RESIDENCE LOT WHERE A 30 FOOT MINIMUM LENGTH APPLIES) 3.THICKNESS: NOT LESS THAN EIGHT (8) INCHES 4.WIDTH: TWELVE (12) FOOT MINIMUM, BUT NOT LESS THAN THE FULL WIDTH AT POINTS WHERE INGRESS OR EGRESS OCCURS. TWENTY-FIVE (25) FOOT MINIMUM IF THERE IS ONLY ONE ACCESS TO THE SITE. 5.GEOTEXTILE MUST BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING OF STONE 6.ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION EXITS SHALL BE PIPED BENEATH THE EXIT. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 7.THE EXIT SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY, ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC RIGHTS-OF-WAY MUST BE REMOVED IMMEDIATELY. 8.WHEN WASHING IS REQUIRED IT SHALL BE DONE ON AN AREA STABILIZED WITH STONE AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 9.PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED ACCORDING TO PERMIT REQUIREMENTS. FLOW NOTES 1.WOVEN WIRE FENCE REINFORCEMENT IS REQUIRED WITHIN 50 FT UPSLOPE OF RECEIVING WATERS. 2.WHERE REQUIRED FENCE SHALL BE WOVEN WIRE, MIN. 14 GAUGE WITH A 6" MESH OPENING SHALL BE USED. 3.FILTER CLOTH SHALL BE EITHER FILTER X, MIRAFI 100X, STABILINKA T140N OR APPROVED EQUIVALENT. 4.POST SPACING FOR WIRE BACKED FENCE SHALL BE 10 FT. MAX. FOR FILTER CLOTH FENCE WHEN ELONGATION IS >50%, POST SPACING SHALL NOT EXCEED 4 FT. FOR FILTER CLOTH FENCE WHEN ELONGATION IS <50%, POST SPACING SHALL NOT EXCEED 6 FT. 5.WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVER-LAPPED BY 6 INCHES AND FOLDED. 6.PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE OR APPROVED EQUIVALENT. 7.MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN SEDIMENT REACHES HALF OF FABRIC HEIGHT. 8.SILT FENCE SHALL NOT BE USED TO DEMARCATE LIMITS OF DISTURBANCE. 9.AREA DRAINING TO SILT FENCE SHALL NOT EXCEED 14 ACRE PER 100 LF Silt Fence/ Reinforced Silt Fence Barrier N.T.S.Source: VHB LD_650-VT 08/16 PLACE 4" OF FABRIC ALONG TRENCH AWAY FROM PROTECTED AREA BACKFILL AND COMPACT 6" MIN. EMBEDMENT A B A B WOOD STAKE JOINT DETAIL STAPLE STAPLE 16 " ( M I N . ) 20 " ( M I N . ) WORK AREA PROTECTED AREA UNDISTURBED AREATOP OF GROUND SEE NOTE #4 SILT FENCE 1 12" X 1 12" X 4' WOOD STAKE OR APPROVED EQUAL MULCH MATERIAL AND APPLICATION MULCH MATERIAL QUALITY STANDARDS PER 1,000 SQ-FT PER ACRE DEPTH OF APPLICATION 1.APPLY TACKIFIER AS NEEDED TO MINIMIZE POTENTIAL FOR MULCH TO BLOW AWAY. 2.MULCH MUST NOT CONTAIN INVASIVE PLANT SPECIES. (SEEDS OR SEEDLINGS) 3.TACKIFIER MAY BE WATER, NETTING, OR SIMILAR. 4.OTHER THAN EROSION CONTROL MIX, MULCH IS NOT TO BE INSTALLED ON SLOPES > 3:1. Mulching Notes and Specifications N.T.S.Source: VHB LD_VT 08/16 TEMPORARY SEEDING 1.AREA TO BE SEEDED MUST BE ROUGH GRADED AND SLOPES PHYSICALLY STABLE. 2.SEEDING METHOD TO RESULT IN GOOD SOIL TO SEED CONTACT. 3.AFTER SEEDING, MULCH THE AREA WITH HAY OR STRAW AT 2 TONS/AC (APPROX 90 LBS/1,000 SF OR 2 BALES/1,000 SF); SEE MULCH DETAIL AND SPECIFICATIONS. 4.MULCH ANCHORING MAY BE NEEDED WHERE WIND OR AREAS OF CONCENTRATED WATER ARE POSSIBLE. 5.WOOD FIBER HYDROMULCH OR OTHER SPRAYABLE PRODUCTS APPROVED FOR EROSION CONTROL MAY BE USED IF APPLIED ACCORDING TO MANUFACTURERS' SPECIFICATIONS. PERMANENT SEEDING 1.SEE SEEDDING SPECIFICATIONS FOR RECOMMENDED SEED MIXES. USE RIPARIAN AND WETLAND SEEDING MIX WITHIN 50 FEET OF STREAM CROSSINGS AND IN DISTURBED WETLAND AREAS. USE UPLAND NATURAL COMMUNITY MIX WITHIN AREAS IDENTIFIED AS SIGNIFICANT NATURAL COMMUNITIES. USE PERMANENT SEEDING MIX FOR ALL OTHER DISTURBED.UPLAND AREAS. SEE VERMONT STANDARDS AND SPECIFICATIONS FOR EROSION PREVENTION AND SEDIMENT CONTROL FOR ADDITIONAL SEED MIXTURES. 2.AREA TO BE SEEDED MUST BE ROUGH GRADED AND SLOPES PHYSICALLY STABLE; CHISELING OR DISKING MAY BE NEEDED IF SOIL IS COMPACTED. 3.SEEDING METHOD TO RESULT IN GOOD SOIL TO SEED CONTACT. 4.PERMANENT SEEDING TO OCCUR PRIOR TO SEPTEMBER 15TH UNLESS WEATHER PERMITS SEEDING BEYOND SEPTEMBER 15TH. 5.AFTER SEEDING, MULCH THE AREA WITH HAY OR STRAW AT 2 TONS/AC (APPROX 90 LBS/1,000 SF OR 2 BALES/1,000 SF); SEE MULCH DETAIL AND SPECIFICATIONS. 6.MULCH ANCHORING MAY BE NEEDED WHERE WIND OR AREAS OF CONCENTRATED WATER ARE POSSIBLE. 7.WOOD FIBER HYDROMULCH OR OTHER SPRAYABLE PRODUCTS APPROVED FOR EROSION CONTROL MAY BE USED IF APPLIED ACCORDING TO MANUFACTURERS' SPECIFICATIONS. 8.IRRIGATION MAY BE NEEDED TO FACILITATE GRASS GROWTH AND ESTABLISH ADEQUATE GRASS COVER. TEMPORARY SEEDING MIX TYPE SEASON RATE (LBS/ACRE) PERMANENT SEEDING MIX* TYPE SEASON RATE (LBS/ACRE) Siltsock - Erosion Control Barrier N.T.S.Source: VHB LD_658 1/16 NOTES 1.LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE FOR DEWATERING. FOUNDATION SHALL BE 2" MINIMUM BELOW THE REST OF THE INLET AND BLOCKS SHALL BE PLACED AGAINST THE INLET FOR SUPPORT. 2.CONCRETE BLOCKS SHOULD BE PLACED LENGTHWISE ON THEIR SIDES IN A SINGLE ROW AROUND THE PERIMETER OF THE INLET. THE ENDS OF EACH BLOCK SHOULD BE ABUTTING. THE HEIGHT OF THE BARRIER CAN BE VARIED DEPENDING ON THE DESIGN BY STACKING VARIOUS COMBINATIONS OF DIFFERENT SIZED BLOCKS. THE BARRIER SHOULD BE A MINIMUM OF 12 INCHES HIGH AND A MAXIMUM OF 16 INCHES HIGH. 3.HARDWARE CLOTH OR 12" WIRE MESH SHOULD BE PLACED OVER THE OPENINGS OF THE CONCRETE BLOCKS AND EXTENDED AT LEAST 12 INCHES AROUND THE OPENING TO PREVENT AGGREGATE FROM BEING TRANSPORTED THROUGH THE OPENINGS IN THE BLOCK. 4.USE CLEAN STONE OR GRAVEL 12" TO 34" IN DIAMETER PLACED 2" BELOW TOP OF THE BLOCK ON A 2H:1V SLOPE OR FLATTER. 5.A 1 FOOT THICK LAYER OF FILTER STONE WILL BE PLACED AGAINST THE 3" STONE. 6.MAXIMUM DRAINAGE AREA PER SEDIMENT TRAP IS 1 ACRE. 7.INSTALL MARSH MAT OR APPROVED EQUAL AT ALL CATCH BASIN GRATES. 8.BLOCK AND STONE INLET PROTECTION REQUIRED AT ALL CATCH BASIN INLETS WHERE THE FINISHED GRADE IS WITHIN 6" OF THE RIM OF THE STRUCTURE OR FRAME. OVERFLOW 1' (MIN.) 2' (MAX.)12" - 16" Erosion Control Blanket Slope Installation N.T.S.Source: VHB LD_680 1/16 NO. 11 GAUGE WIRE TYPICAL STAPLES NOTES 1.BEGIN AT THE TOP OF BLANKET INSTALLATION AREA BY ANCHORING BLANKET IN A 6" DEEP TRENCH BACKFILL AND COMPACT TRENCH AFTER STAPLING. 2.ROLL THE BLANKET DOWN THE SWALE IN THE DIRECTION OF THE WATER FLOW. 3.THE EDGES OF BLANKETS MUST BE STAPLED WITH APPROX. 4 INCH OVERLAP WHERE 2 OR MORE STRIP WIDTHS ARE REQUIRED. 4.WHEN BLANKETS MUST BE SPLICED DOWN THE SWALE, PLACE UPPER BLANKET END OVER LOWER END WITH 6 INCH (MIN.) OVERLAP AND STAPLE BOTH TOGETHER. 5.METHOD OF INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS. 6.EROSION CONTROL BLANKETS SHALL BE USED IN ALL AREAS WHERE SLOPES EXCEED 3:1. 6" 1 12"1 12" 10 " 6" LOAM & SEED STAPLE 12" ON CENTER 6" O V E R L A P (M I N . ) 4" OVERLAP (MIN.) 6" STAPLES 12" ON CENTER STAPLES 12" ON CENTER Seeding Notes and Specifications N.T.S.Source: VHB LD_VT 08/16 TOP OF GROUND BIODEGRADABLE MESH NETTING WOOD CHIP FILLED FILTER SOCK (12" TYP.) WORK AREA PROTECTED AREA RUNOFF WATER WITH SEDIMENT SEDIMENT WIRE SCREEN2:1 SLOPE GRAVEL FILTER WIRE SCREEN CONCRETE BLOCK GRAVEL FILTER FILTERED WATER DROP INLET WITH GRATE of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo. vh b . c o m Date 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Ph 2A Local Approval July 29, 2021 35 57913.01 EPSC Details C8.01 16 SMW PBS Issued for Construction 10/17/2022 PBS1