Loading...
HomeMy WebLinkAboutPermit Wastewater Connection WW-06-3868 )6 Permit Number WW- - 3 ez 8 City of South Burlington, Vermont Application for Wastewater Connection Property Owner: no/O Pay k Po_v-4-4 c-//'S Phone: 0-/67/X7 Address: 3 -21/ ,� NlQ/,'ve_ ki ,. l �6inn, / /7— Applicant: Re. , rL1\ ✓ Phone: FJ-S 7‘ 7 Address: 30 C(,-vy� u 7L j) i-y ��r r�1 /3 /t� vh . yr Project Location: .53 C-,-Y,,,-,,n,,,i,/- fir,'���- ❑ Residential FYtommercial y ❑ On-Site Septic Person or firm doing the work: ,,i)t✓ Arm I Phone: 63—g7Z7 Address: s< C1,-�, /A ±j Jf,'v" Sketch of Sewer Connection (For Inspector Use Only): In consideration of the granting of this permit,the undersigned agrees: 1. To accept and abide by all provisions of the Sewer Ordinance,as from time to time amended,of the City of South Burlington, and all other pertinent ordinances or regulations that may be adopted in the future. 2. To maintain the building sewer at no expense to the City. 3. To notify the Department of Public Works when the sewer is ready for inspection and connection to the public sewer before any portion of the work is covered. 4. To notify the Department of Public Works at least two(2)working da sin advance of the requested time for sewer inspection. Call 658-7961 for an appointmen Applicant Signature: a � p Date: 8 I l j 0 C Inspection Fee: e Recording Fee: �v Application: ❑ Rejected // 1 Code Officer Signature: —of „ �, Date: /0/0(6 Date of Inspection: / Inspector's Signature: f /19L ' 54k kil t 0 /1 6NkS ADO l'---14/0- 1- „,,,,'‹.4• ' ,-.k.,,.•01XL, , '4,,,t4 ., 'I, 'it , ...” 11; „, 2. '.'•"04. -,.. i t \ sue. �` '.,- L `ay,� }} .� . • ' " ' o . 1.,k .1' yTt1' •,� C , - r �1kz. t .75. At'ti �� ,1, 440 '1 l ` M al � t 1 1 q,j • �• fi '4 6.< C. fi xV. 1 /if Zr- ,.'4,4' "":'''.:-! *, 't...'1.:,4i 4. ,,'‘,..1,4.‘„ AmA,d' . —4„,„ -,r,,,i _A=,' , , . . tt 111 e »' zAa Yi M! r *Pr r t j, s 'TA fi f:rF' . •r r a' lair, .' .1r E , f , 1( / I "i3 � A hit`• ` .'F• . ri tt^r ' t k ' Ilt,,' • {Ar • t AF .r fr i F.# 1 \ tn 4. 1 .... ,.. yf ys r.1,iy : tix 'l %a ' ...,4, /, glkfir + t, _ t T Y ti l• p ! O , y, irm `• f5 'x ;1 _ s ...we 1 lik 1161 ' k , ... lik ,1 .'1411 II 4 . .. . . . , . ,,.. - , - , .. < ,- . . 0.ri-4. , -,..,4..-.";, , ,, ,i,..-3.... p411,,,. , :,,, ,:...: , .,,,,., ,..v 4-,, - , • ,..,,,', •Y:,...„,..,•?:,-„,_,, ,S� '�� t lu(r .rSi+� '' Y!• ',1.h6.ff'l � „ .Yr "s `• �' 7 sk' c , r'p mod•+ . 's" yam- 1 s .t t 1 ayl 1 1y£f !, Lt ( 4 - (J v t•r.r _ : t,J i • 4i1�, b 4:f /'F S��'u ,; .��( ` , �,p rt, r • 1 �r __ t �. A t r 'fy �. Lr. t /� X T1f •t ty' air a ,hf.,_,.. t• • xL l�11 .l '4. j� . "4. , v. f; y, ti 7 i , a-R''' t r 10,141.. - '1 ' '' ' '''''.-, 1. '} T 1 •1(. r " •••*.x4.-'-1:i, ''.' vi/1 ... , ..- -,-.. • , ":•--4.4/4,1` ' 44ft, 7 ' - .'- Wil, .- i fl iJ vl`c o 7, �• . y.�. fit Ih AIS. . } y'�`{��;y L! :114f,-; ''4. �J{s D 1 "4. Aid. '+ f,' ai 9� :;.:,:,....i • ., , . 1,°:,-_a IN., 4 t$,. fr., '4. NA Ir. .0 ,,,,.i 4144 . - 10,;144 :.".. . -..ti fr ,„ • k,'''..''•;''''''°i• „„, •;„ •. J° is -':.14 \t„.tt*.•,4,t4 :::.."1i..*le_44‘,,,,,,,,,,d,}1) . A.._ 4. r. { ,'} # "". sue. 1 * .'Y• t.t! lam• ` `iI 4. ' - 74-Titiz...4,4\11\..\ --. iii, . -- ti st R!./ - .. , F R ',' ' ' -,',4‘ -1`- ..' •`-' '' t' ' - k ' ' '•''-• if, ' ' - *4,1! ,,,,, ' , , r,/ter r,- . v f l N. ,. "•}rAil . , /-• • N �•,f1,- *'1'Ft:' t. Tech Park - Lot 7 Page 1 of 2 Bruce Hoar From: Robert Gallo [Robert@trudellconsulting.com] Sent: Monday, January 07, 2008 11:27 AM To: Bruce Hoar Subject: FW: Tech Park- Lot 7 Bruce, Is there any additional info that you need from me to sign off on the connection to the Municipal system? Thanks. Bob From: ray [mailto:rbelair@sburl.com] Sent: Monday, January 07, 2008 10:44 AM To: Robert Gallo Subject: RE: Tech Park - Lot 7 Bob, (11 The sewer service line connection authorized by perm #WW-06-3868 as not yet been inspected by DPW. Ray Belair Administrative Officer City of So. Burlington 802-846-4106 From: Robert Gallo [mailto:Robert@trudellconsulting.com] Sent: Monday, January 07, 2008 9:56 AM To: Bruce Hoar; ray Subject: FW: Tech Park - Lot 7 Bruce and Ray, Has this issue regarding the sewer tie-in been addressed? I haven't heard anything about it. Thanks. From: Kevin Neil [mailto:Kevin@rearchcompany.com] Sent: Monday, January 07, 2008 9:27 AM To: Robert Gallo Cc: Josh Quinn; Bert Delabruere Subject: FW: Tech Park - Lot 7 Bob, Has Bruce sent this info to Ray Blair yet? We are looking to occupy the building in two weeks. Please let me know where we stand on this. Time is running short. Thanks, Kevin From: Robert Gallo [mailto:Robert@trudellconsulting.com] Sent: Thursday, November 29, 2007 12:41 PM To: Bruce Hoar Cc: Jeremy Matosky; Kevin Neil 1/7/2008 Tech Park- Lot 7 Page 2 of 2 Subject: Tech Park - Lot 7 Bruce, Ray Belair is waiting on a report from your office regarding the sewer tie-in at Kimball Avenue before he issues the CO on Lot 7. The work was done this past May. During the inspection, the representative from your office did not want the native material put back into the excavation, so Ireland brought in new material and backfilled as directed. I have included a photo layout of the work for your records, and to help along with the report to Ray. Can you please copy me on your report to Ray so I can add it to our records? Thanks. Bob Gallo-Project Manager Trude]] Consulting Engineers(TCE) P.O. Box 308 Williston,VT 05495 Ph: (802) 879-633] Fax: (802)879-0060 email: robert@trudellconsulting.com «Kimball Tie-in Photos.pdf» *** VT Sky has scanned this email for malicious content *** *** Word to the Wise: Do not open attachments from unrecognized senders *** 1/7/2008 `ter' TRUDELL CONSULTING ENGINEERS (TCE) January 8,2008 tel:802-879-6331 Fax:802-879-0060 www.trudellconsulting.com Vermont Agency of Natural Resources Wastewater Management Division 111 West Street Essex Junction,VT 05452 RE: Engineer's Certification(WW-4-1506)—Technology Park Lot 7 Dear Wastewater Management: This letter is in response to Condition# 11 of the Water Supply and Wastewater Disposal permit#WW-4- 1506 issued on April 9th,2001. We observed construction of building sewer,pump station,force main,and gravity sewer that serve this project,on several dates in the Fall of 2006 using a reasonable standard of care customary for this scope of work. Listed below is a brief sumrnary of our findings: 1. The contractor is S.D.Ireland Company. 2. The pump station is an 8' diameter pre-cast concrete structure that contains the pumps(duplex system)and floats,with an exterior mounted control panel and alarm. The pumps are Barnes 4XSE3034A submersible non-clog pumps(3.0 HP). 3. The pump station valve pit is a 5'diameter concrete structure that contains the associated gate valves and check valves. 4. The junction manhole is a 6'diameter concrete structure that contains the associated gate valves and check valves. 5. The pump station vent was installed with an odor control device. 6. The force main is 4-inch DR18 PVC. A hydrostatic pressure test was conducted on the 4-inch force main. Pressure was established at 58 psi. The pressure held constant for a period in excess of 2 hours with no measurable loss. 7. The 3-inch DR 18 PVC force main that was constructed from the east side of Community Drive to the force main discharge manhole was hydrostatically tested. Pressure was established at 64 psi. The pressure held constant for a period in excess of 2 hours with no measurable loss. 8. Manholes 1-7 were vacuum tested to 10 inches of mercury. All of the tested manholes lost less than the allowable 1-inch drop in vacuum pressure,and all structure vacuum pressures remained above the minimum of 9 inches of mercury(see attached test results). Manholes 1-7 passed their respective vacuum tests. 9. The 8-inch SDR 35 PVC gravity sewer lines linking the manholes,as well as the gravity sewer connecting the gravity collection system to the existing manhole at Kimball Avenue,were air tested to the applicable pressures. All of the tested lines held steady pressures throughout the test duration, and passed(see attached test results). P.O. Box 308 478 Blair Park Road Williston, Vermont 05495 Civil Engineering, Surveying, Land Planning, Water and Wastewater, Landscape Architecture. Roadway Design, Permitting Based on the above observations,this letter can serve as confirmation that the system was installed in general conformance with the approved plans. This does not relieve the contractor of minor adjustments that may be needed during the initial startup of the system,nor does it relieve the owner of proper use and maintenance. This letter is not intended to imply any type of warranty or guarantee from the engineer since both the use and maintenance are beyond our control. However,given the good workmanship of S.D. Ireland Company,we are not anticipating any problems. Very truly yours, TRUDELL CONSULTING ENGINEERS (TCE) t5Q, A3--U0 Bob Gallo Project Manager Certification Statement: I,Jeremy M.Matosky,P.E.,herby certify that the designs-related information is true and correct and that,in the exercise of my reasonable professional judgment,the design of the wastewater collection and conveyance system meets the technical standards of the Rules. "I also herby certify that in the exercise of my reasonable professional judgment the installation-related information submitted is true and correct and that the potable water supply and wastewater system were install accordance with the permitted design and all permit conditions;were inspected,were properly t ed; . d h. successfully met those performance tests." ,,. " OF v R''{. J 'tiny M.Mat• y;,p.E. 0 No.7637 *� Encl. Air test results,vacuum to i N$'o : 0�NA. ►`-0 cc. Kevin Neill—ReArch,Bruce Hoar—City of South Burlington S:\TCE PROJEC1b\2007\100 Tech Park\L.ot7\Certifications\TPLot7SewerCeit010808.doc Trudell Consulting Engineers - Sewer Line Test Documentation Sheet Project Description: ys.srAt t —t)Ct„ 2r\o L,7t'�) Observed By: a ez, 6At.{ TCE Project Number: 1.17 a o O(A1e) Test Date: .5\att \01 Leakage Test Deflection Test Uniform Slope Test Air Pressure Mandrel Lamp/Camera Sewer Pipe Section Pipe Material Diameter Lineal Specified PS1 Date Date o Date I Pass/Fail Pass/Fail { ((Inches) Feet }`V' Vtime drop Tested ed Tested MH# MH# 5p4 4� C . I7,.+ f- �J sue, muMH# MH# '$ 1 I t '3 } t 0' ! 0 it I r t ��J ,I J MH# S MH# e� i I f ttr Lid 1 si' 10 0 ‹ t t MH# MH# :( I ( f t ' 't 0.1, I € Iif ?&5 MH# MH# `, A Jar}r : ej 0MH# '2„ MH# { Z i t~ ' (lam �6 ppp E C) r t MH# MH# MH# MH# t MH# MH# MH# MH# I MH# MH# 1 MH# MH# MH# MH# ^MH# MH# I I Documents Trudell Consulting Engineers - - Manhole Vacuum Test Documentation Sheet . ' Project Description: `V[�.� v�...5 �`,,— Observed By: b • -t D TCE Project Number: ivo pt-t,t Test Date: 5 t L 01 Manhole Manhole Manhole 1 Manhole 1 Spec.Test Actual Drop 1 Pass-Fail Test Date Manhole Clean ( Steps Number Manufacturer Diameter(ID) Height Time Test I Re-Test Yes I No Yes I No yy f L( 1. . ` V- 2-5` Y II alfrt.o '41 'ZLkc ) f.c '` I q-- cr I I I _ I 1 Documents TRUDELL CONSULTING ENGINEERS (TCE) tel:802-879-6331 January 8,2008 fax:802-879-0060 www.trudellconsulting.com City of South Burlington Dept.of Public Works—Attn:Bruce Hoar 500 Patchen Road South Burlington,VT 05403 RE: Technology Park Lot 7—Municipal Sewer Connection Certification Dear Bruce: I am writing regarding the municipal building connection to the pump station at Lot 7. I observed the connection to the pump station on 11/15/06 and have attached photos from that site visit. The service connection was installed in general conformance with the approved design plans,and in general conformance with the State of Vermont Wastewater System and Potable Water Supply Rules. The entire connection was bedded in stone. Given the proximity of the pump station to the building,the entire pump station excavation was also backfilled with crushed stone,to prevent settlement of the pump station,pipes, and surface area around the station. The attached photos show the building connection very clearly. Also,please see the attached State certification that was prepared to comply with conditions of the site's Wastewater System and Potable Water Supply Permit.Please let me know if you require any additional information regarding the connection. I can be reached at(802)879-6331. Very truly yours, "1RUDELL CONSULTING ENGINEERS(TCE) Bob Gallo Project Manager End. Photo Layout cc. Kevin Neill—ReArch Company S:\ TCE PROJECTS\2007\100 Tech Parte\Lot 7\MuncipalConnectionCertiScation010808.doc P.O. Box 308 478 Blair Park Road Williston, Vermont 05495 Civil Engineering, Surveying, Land Planning, Water and Wastewater, Landscape Architecture. Roadway Design, Permitting