HomeMy WebLinkAboutSP-23-047 - Supplemental - 0017 Reel Road (2)
November 9, 2023
Marty Gillies
Development Review Planner
City of South Burlington Planning & Zoning Department
180 Market Street, South Burlington, VT 05401
Re: 10 Fayette Road – Retrofitting Existing Building for Indoor Recreation Facility
Water and Wastewater Analysis
Dear Marty,
We reviewed your email regarding water and wastewater flows for the above referenced project. We
have not found historical allocation for the existing Palace 9 movie theater. For this calculation we are
going to review flows based on the State of Vermont Chapter 1 – Wastewater System and Potable Water
Supply Rules. We feel if we compare the values using the same regulations, it provides us with the most
consistent comparison.
Existing Use – 9 Theater Movie Complex with Food Concession and ±1,000 seats
1,000 seats * 3 GPD per seat = 3,000 GPD
1 Concession Area = 100 GPD
Total = 3,100 GPD
Proposed Use
1. ±14,900 s.f. of the building will be used for the proposed Indoor Recreation Facility. We feel the
following calculation is a conservative evaluation for the number or persons using the facility.
±40 participants * 8 GPD per participant with showers = 320 GPD
±40 spectators * 3 GPD per Spectator = 120 GPD (high unlikely amount)
±5 employees * 13 GPD per employee = 65 GPD
Total for this portion of the building = 505 GPD
2. ±5,700 s.f. of the building – Unknown at this time.
This change in use will heavily reduce the amount of water/sewer used in the building. The project is not
revising the utility connections and the existing infrastructure will be able to handle the reduction in
flow. If needed, we will generate an Engineers Certification to be recorded in City Records for the
change in use and reduction in flow.
Sincerely,
Greg Dixson, P.E.
Krebs and Lansing Consulting Engineers, Inc.