Loading...
HomeMy WebLinkAboutZP-23-423 - 0061 Russet Road 12/14/2023ZP-23-423 12/12/2023 1,504.20 single family dwelling #SD-18-28 11/26/18 SEQ NR 12/14/2023 12/29/2023 12/13/2024 (Acting) Property Owners Name:JJJ South Burlington Property Location:61 Russet Road Amount:13,869.29 Payment Type:check #0777 Date:11/1/2023 Code Zoning Permit (New Residential)ZP-23-423 zp Recording fee 13.00$ plus 2162 0.45$ per sq. ft. 972.90$ plus 2092 0.20$ per sq. ft. 418.40$ plus 2 50.00$ per bay 100.00$ plus After-the fact of 50% [no NOV] or 100% [NOV] -$ Zoning Permit Total 1,504.30$ Sewer Allocation Fee WWA-23-164 #204 234.52 g.p.d x 14.57$ 3,416.96$ Bartlett Bay x Airport Parkway Impact Fee Administration Fee #248 100.00$ per application 100.00$ School Impact Fee #222S 4,258.35$ Recreation Impact Fee #220 $1,665.08 per unit 1,665.08$ South Village Recreation Impact Fee #243 per unit Road Impact Fee #221 954.51$ per unit 954.51$ Cider Mill Impact Fee* *See #SD-18-28 #213 1,000.00$ per unit 1,000.00$ Fire Impact Fee #203 -$ Police Impact Fee #222 496.80$ per unit 496.80$ Dorset Street Waterline Fee #230 $410.29 per unit 410.29$ Sewer Connection Inspection WW-23-64 ww 63.00$ per connection 63.00$ Total (Impact Fees + Permit) 13,869.29$ Planning & Zoning Invoice Residential Impact & Permit Fees garage bay(s) at Amount Due sq. ft building at sq. ft unfinished basement at FOR REVIEW ONLY NOT FOR CONSTRUCTION SHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILD SCALE: DATE: DRAWN BY: CHECKED BY: PROJECT: SHEET SIZE:11/27/2023 10:20:52 AMA100COVER SHEETDOUSEVICZ #61 Russet G4 G4 11/27/23 123VERMONT ARCH D 24"x36" GENERAL NOTES: 1) WINDOW HEADS @ 8'-0" A.F.F. ON FIRST UNLESS OTHERWISE DIMENSIONED 2) DWGS ARE INCOMPLETE UPON OWNERS REQUEST. G4 DESIGN STUDIOS IS NOT LIABLE FOR ERRORS OR OMISSION THAT MAY OCCUR IN THE DRAWING SET 3) CONTRACTOR TO COORDINATE TRANSOMS ABOVE DOORS 4) UNLESS NOTED OTHERWISE ALL INTERIOR WALLS TO BE 2X4 @ 16" O/C 5) ROOF SYSTEM TO BE DESIGNED BY TRUSS MANUFACTURER & SHOPS TO BE REVIEWED BY CONTRACTOR 6) FRAMING SYSTEMS TO BE DESIGNED BY STRUCTURAL TEAM 7) G4 DESIGN STUDIOS NOT RESPONSIBLE FOR VERMONT RESIDENTIAL ENERGY CODE DRAWINGS ARE FOR DESIGN PURPOSES ONLY 8) WINDOWS TAGS: 2650 MEANS 2'-6" WIDE BY 5'-0" HIGH CS MEANS CASEMENT DH MEANS DOUBLE-HUNG 2W MEANS TWO UNITS MULLED TOGETHER FX MEANS FIXED AWN MEANS AWNING 9) DOOR TAGS: 3068 MEANS 3'-0" WIDE BY 6'-8" HIGH PKT MEANS POCKET EXT MEANS EXTERIOR FRT MEANS FRONT ARCHITECTURAL NOTES: ALL DIMENSIONS ARE TO FACE OF INTERIOR WALL STUD AND EXTERIOR WALL STUD. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO ARCHITECT/DESIGNER. PLUMBING FIXTURES, APPLIANCES, CABINETS AND LIGHTING FIXTURES TO BE DETERMINED BY OWNER. CONTRACTOR TO COMPLY WITH LOCAL BUILDING CODES & VERMONT ENERGY CODES. ALL BATHROOM WALLS & CEILINGS TO BE 1/2" MOISTURE RESISTANT GWB. BATHROOM WALLS TO BE SOUND INSULATED. ALL HEADERS OVER OPENINGS TO BE SIZED BY CONTRACTOR. G4 DESIGN STUDIOS IS NOT RESPONSIBLE FOR FRAMING DETAILS, STRUCTURAL DETAILS, FINISH WORK, MILLWORK, WEATHER TIGHT CONSTRUCTION, FINISH GRADING OR CONCRETE WORK. GENERAL CONTRACTOR TO COORDINATE WITH CONCRETE CONTRACTOR AND OWNER FOR PENETRATIONS THROUGH CONCRETE SLAB & FOUNDATION WALL IF OWNER/CONTRACTOR MAKE CHANGES DURING THE CONSTRUCTION PROCESS WITHOUT WRITTEN AUTHORIZATION FROM G4 DESIGN STUDIOS (G4). G4 IS NOT LIABLE FOR ERRORS OR OMISSIONS THAT MAY OCCUR DURING CONSTRUCTION. OWNER TO SELECT WINDOW MANUFACTURER, VERIFY WITH OWNER PRIOR TO ORDERING WINDOWS. GENERAL CONTRACTOR TO COORDINATE WITH MECHANICAL CONTRACTOR FOR HVAC SYSTEM. GENERAL CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR & OWNER FOR LOCATIONS OF OUTLETS, LIGHTING FIXTURES, CABLE, INTERNET & LIGHT SWITCH LOCATIONS. 2020 VERMONT RESIDENTIAL BUILDING ENERGY STANDARDS: NEW CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING R-VALUES (BASED ON HERS RATING) AIR LEAKAGE LESS THAN OR = 3 ACH50 SLAB INSULATION = UNHEATED R-10, HEATED R-15 BASEMENT/FOUNDATION WALLS = R-15 CONTINOUS / R-19 CAVITY FLOORS = R30 WINDOWS/SKYLIGHTS = U-.30/U-.55 ABOVE GRADE FRAMED WALLS = R-20 CAVITY OR R-13 CAVITY + R-5 CONTINOUS CEILINGS =R49 CONTRACTOR TO COMPLY WITH LISTED THERMAL VALUES AND WITH ALL ADDITIONAL REQUIREMENTS OF THE 2020 VTRBES 22' - 0"18' - 0" GARAGE OH1608042' - 0"14' - 0"22' - 0"8' - 0"72' - 0"SHARED BATHROOMMASTER BEDROOM KITCHENPANTRYMASTER BATHROOM MASTER CLOSET BEDROOM #2 BEDROOM #3 DINING ROOM MUDROOMW/D13' - 8"6' - 1"13' - 3 1/2"6' - 6"3' - 6"2' - 2"6' - 2 1/2"3' - 1 1/2"4' - 7 1/2"13' - 1 1/2"2' - 1"12' - 2"37' - 6 1/2"5' - 0"3' - 9"9' - 9 1/2"5 1/2" 40' - 0"3' - 0"4' - 9 1/2"2' - 9"5' - 1"4' - 0"68' - 0"4' - 0"19' - 0"21' - 0"8' - 10"3' - 6"2468 10' - 0"12' - 0"11' - 0"17' - 6"18' - 2"3' - 8 1/2"4' - 0"15' - 8 1/2"LIVING ROOM FRONT PORCHDH3050CS2626CS2626DH3060-3W (EGRESS) T3014 23' - 3"3' - 3 1/2"5' - 9 1/2"9' - 8"8' - 0"4' - 4" 5' - 0" 7' - 0"7' - 0" CS3040-3W 4' - 0"10' - 0"10' - 2"20' - 10"13' - 0"10' - 0"15' - 2"DH3060-2WDH3060-2WCS3040DH3060DH3060DH3060DH3060 (EGRESS)18' - 0"9' - 3"9' - 5 1/2"2' - 2"8' - 0"7' - 3"3068 EXT30683068PKT-306828683068 SL5068SL50683068 PKT-3068 6068 5068 3068 3068 28682668 3068 EXT30683068 3068 4' - 0"4' - 0"4' - 0"10' - 0"9' - 0"9' - 0" DH3060 DH3060 DH3060 EXTERIOR PATIO 3' - 1 1/2"16' - 0"2' - 6 1/2"6' - 6"DROP HEADER5 1/2"5 1/2"13' - 1 1/2"4' - 1 1/2" 4' - 9" 5 1/2" 6' - 10"6' - 0"2' - 1"FIRST FLOOR SQ-FT: 2,093 SQ-FT WITHOUT GARAGE 40' - 0" 40' - 0"64' - 0"8' - 0"19' - 0"21' - 0"24' - 0"47' - 0"21' - 0"SL301822' - 0"18' - 0" SL4646 40' - 0"UNFINISHED BASEMENT 9'-2" FOUNDATION WALL PER CONTRACTOR EGRESS WINDOW SILL (S) NOT TO BE HIGHER THAN 44" ABOVE FLOOR PERIMETER FOOTING DRAIN TO DAYLIGHT PER CIVIL DWGS. (TYP.) FOUNDATION NOTES: CONTRACTOR TO COORDINATE WITH CONCRETE CONTRACTOR FOR SIZE, TYPE & LOCATION OF ALL REINFORCING IN FOUNDATION WALLS & FOOTINGS. G4 DESIGN STUDIOS IS NOT RESPONSIBLE FOR FOUNDATION, FOOTINGS, SLAB & REINFORCING FINISH GRADING TO BE DETERMINED BETWEEN OWNER & CONTRACTOR OR CIVIL ENGINEER.SLOPE 1/4” PER 12”INSIDE MIN.3' - 0"4' - 9"17' - 3" 14' - 0"26' - 0"68' - 0"FOOTING SIZED BY ENGINEER OR G.C. (TYP.)4' - 0"12' - 0"20' - 0"4' - 4"21' - 8" PATIO ABOVE6' - 0"12' - 0"10' - 0"78' - 0"3' - 0"16' - 3"2' - 5" GARAGE DOOR CUT COORDINATE W/ CONTRACTOR SLAB ON GRADE SLAB 4" BELOW T.O. FOUNDATION WALL3' - 10 1/2"10' - 0"3' - 8"17' - 2 1/2"17' - 9 1/2" WINDOW WELL BY CONTRACTOR PER NFPA 101 SEC. 24.2.2.3.3 (4) CONTRACTOR TO VERIFY STAIRS UP 16R @ 7.72" (7.75” MAX) 15T @ 10" (10” MIN) FOR REVIEW ONLY NOT FOR CONSTRUCTION SHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILD SCALE: DATE: DRAWN BY: CHECKED BY: PROJECT: SHEET SIZE:11/27/2023 10:21:00 AM 3/16" = 1'-0"A101FLOORPLANSDOUSEVICZ #61 Russet G4 G4 11/27/23 123VERMONT ARCH D 24"x36" 3/16" = 1'-0"1 FIRST FLOOR PLAN 3/16" = 1'-0"2BASEMENT First Floor 412' - 6" First Floor TP 421' - 7 1/8" Pre-Con Grade 410' - 0" 6" WHITE BEVEL HORIZONTAL SIDING 6" WHITE BEVEL HORIZONTAL SIDING 4" CORNER TRIM (TYP.) MATCH COLOR TO SIDING ASPHALT SHINGLES 1' OVERHANG (TYP.) DARK RED 12" BOARD & BATTEN PLANTER BOX W/ METAL ANGLE BRACKETS 6" HORIZONTAL TRIM BOARD DOUGLAS FIR FINISH W/ 24" BRACKET MATCH TRIM COLOR TO SIDINGFX2020 TO MIDPOINT OF HIGHEST ROOFPEAK17' - 1" +/-First Floor412' - 6" First Floor TP 421' - 7 1/8" Pre-Con Grade 410' - 0" 10 12 HD HGT.8' - 0"WINDOW WELL BY CONTRACTOR 12" +/- WRAP BOARD & BATTEN TO MIDPOINT OF HIGHEST ROOFPEAK17' - 1" +/-First Floor 412' - 6" First Floor TP 421' - 7 1/8" Pre-Con Grade 410' - 0" 6" WHITE BEVEL SIDINGWRAP BOARD & BATTEN 10 12 8' - 0"First Floor412' - 6" First Floor TP 421' - 7 1/8" Pre-Con Grade 410' - 0" ASPHALT SHINGLES HD HGT.8' - 0"1' - 0"1' - 0"1' - 0" WHITE TRIM WINDOW WELL BY CONTRACTOR PER NFPA 101 SEC. 24.2.2.3.3 (4) FOR REVIEW ONLY NOT FOR CONSTRUCTION SHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILD SCALE: DATE: DRAWN BY: CHECKED BY: PROJECT: SHEET SIZE:11/27/2023 10:21:11 AM 3/16" = 1'-0"A102ELEVATIONSDOUSEVICZ #61 Russet G4 G4 11/27/23 123VERMONT ARCH D 24"x36" 3/16" = 1'-0"1 South 3/16" = 1'-0"2West 3/16" = 1'-0"3East 3/16" = 1'-0"4 North