HomeMy WebLinkAboutZP-23-423 - 0061 Russet Road 12/14/2023ZP-23-423
12/12/2023 1,504.20
single family dwelling
#SD-18-28 11/26/18
SEQ NR
12/14/2023
12/29/2023 12/13/2024
(Acting)
Property Owners Name:JJJ South Burlington
Property Location:61 Russet Road
Amount:13,869.29 Payment Type:check #0777 Date:11/1/2023
Code
Zoning Permit (New Residential)ZP-23-423 zp Recording fee 13.00$
plus
2162 0.45$ per sq. ft. 972.90$
plus
2092 0.20$ per sq. ft. 418.40$
plus
2 50.00$ per bay 100.00$
plus
After-the fact of 50% [no NOV] or 100% [NOV] -$
Zoning Permit Total 1,504.30$
Sewer Allocation Fee WWA-23-164 #204 234.52 g.p.d x 14.57$ 3,416.96$
Bartlett Bay
x Airport Parkway
Impact Fee Administration Fee #248 100.00$ per application 100.00$
School Impact Fee #222S 4,258.35$
Recreation Impact Fee #220 $1,665.08 per unit 1,665.08$
South Village Recreation Impact Fee #243 per unit
Road Impact Fee #221 954.51$ per unit 954.51$
Cider Mill Impact Fee* *See #SD-18-28 #213 1,000.00$ per unit 1,000.00$
Fire Impact Fee #203 -$
Police Impact Fee #222 496.80$ per unit 496.80$
Dorset Street Waterline Fee #230 $410.29 per unit 410.29$
Sewer Connection Inspection WW-23-64 ww 63.00$ per connection 63.00$
Total (Impact Fees + Permit) 13,869.29$
Planning & Zoning Invoice
Residential Impact & Permit Fees
garage bay(s) at
Amount Due
sq. ft building at
sq. ft unfinished basement at
FOR REVIEW ONLY
NOT FOR CONSTRUCTION
SHEET TITLE:THIS DRAWING IS THE PROPERTY
OF G4 DESIGN STUDIOS, LLC AND
IS NOT TO BE COPIED,
REPRODUCED, OR THE CONTENT
THEREOF USED, IN WHOLE OR IN
PART, WITHOUT THE PRIOR
WRITTEN CONSENT OF STEVE
GUILD
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT:
SHEET SIZE:11/27/2023 10:20:52 AMA100COVER
SHEETDOUSEVICZ
#61 Russet
G4
G4
11/27/23
123VERMONT
ARCH D
24"x36"
GENERAL NOTES:
1) WINDOW HEADS @ 8'-0" A.F.F. ON FIRST UNLESS
OTHERWISE DIMENSIONED
2) DWGS ARE INCOMPLETE UPON OWNERS REQUEST.
G4 DESIGN STUDIOS IS NOT LIABLE FOR
ERRORS OR OMISSION THAT MAY OCCUR IN
THE DRAWING SET
3) CONTRACTOR TO COORDINATE
TRANSOMS ABOVE DOORS
4) UNLESS NOTED OTHERWISE ALL INTERIOR
WALLS TO BE 2X4 @ 16" O/C
5) ROOF SYSTEM TO BE DESIGNED BY TRUSS
MANUFACTURER & SHOPS TO BE REVIEWED BY
CONTRACTOR
6) FRAMING SYSTEMS TO BE DESIGNED BY
STRUCTURAL TEAM
7) G4 DESIGN STUDIOS NOT RESPONSIBLE FOR
VERMONT RESIDENTIAL ENERGY CODE
DRAWINGS ARE FOR DESIGN PURPOSES ONLY
8) WINDOWS TAGS:
2650 MEANS 2'-6" WIDE BY 5'-0" HIGH
CS MEANS CASEMENT
DH MEANS DOUBLE-HUNG
2W MEANS TWO UNITS MULLED TOGETHER
FX MEANS FIXED
AWN MEANS AWNING
9) DOOR TAGS:
3068 MEANS 3'-0" WIDE BY 6'-8" HIGH
PKT MEANS POCKET
EXT MEANS EXTERIOR
FRT MEANS FRONT
ARCHITECTURAL NOTES:
ALL DIMENSIONS ARE TO FACE OF INTERIOR WALL STUD AND EXTERIOR WALL STUD. FIELD VERIFY ALL DIMENSIONS
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO ARCHITECT/DESIGNER.
PLUMBING FIXTURES, APPLIANCES, CABINETS AND LIGHTING FIXTURES TO BE DETERMINED BY OWNER.
CONTRACTOR TO COMPLY WITH LOCAL BUILDING CODES & VERMONT ENERGY CODES.
ALL BATHROOM WALLS & CEILINGS TO BE 1/2" MOISTURE RESISTANT GWB. BATHROOM WALLS TO BE SOUND INSULATED.
ALL HEADERS OVER OPENINGS TO BE SIZED BY CONTRACTOR.
G4 DESIGN STUDIOS IS NOT RESPONSIBLE FOR FRAMING DETAILS, STRUCTURAL DETAILS, FINISH WORK, MILLWORK, WEATHER TIGHT CONSTRUCTION, FINISH GRADING OR CONCRETE WORK.
GENERAL CONTRACTOR TO COORDINATE WITH CONCRETE CONTRACTOR AND OWNER FOR PENETRATIONS THROUGH CONCRETE SLAB & FOUNDATION WALL
IF OWNER/CONTRACTOR MAKE CHANGES DURING THE CONSTRUCTION PROCESS WITHOUT WRITTEN AUTHORIZATION FROM G4 DESIGN STUDIOS (G4).
G4 IS NOT LIABLE FOR ERRORS OR OMISSIONS THAT MAY OCCUR DURING CONSTRUCTION.
OWNER TO SELECT WINDOW MANUFACTURER, VERIFY WITH OWNER PRIOR TO ORDERING WINDOWS.
GENERAL CONTRACTOR TO COORDINATE WITH MECHANICAL CONTRACTOR FOR HVAC SYSTEM.
GENERAL CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR & OWNER FOR LOCATIONS OF OUTLETS, LIGHTING FIXTURES, CABLE, INTERNET & LIGHT SWITCH LOCATIONS.
2020 VERMONT RESIDENTIAL BUILDING ENERGY STANDARDS:
NEW CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING R-VALUES (BASED ON HERS RATING)
AIR LEAKAGE LESS THAN OR = 3 ACH50
SLAB INSULATION = UNHEATED R-10, HEATED R-15
BASEMENT/FOUNDATION WALLS = R-15 CONTINOUS / R-19 CAVITY
FLOORS = R30
WINDOWS/SKYLIGHTS = U-.30/U-.55
ABOVE GRADE FRAMED WALLS = R-20 CAVITY OR R-13 CAVITY + R-5 CONTINOUS
CEILINGS =R49
CONTRACTOR TO COMPLY WITH LISTED THERMAL VALUES AND WITH ALL ADDITIONAL REQUIREMENTS OF THE 2020 VTRBES
22' - 0"18' - 0"
GARAGE
OH1608042' - 0"14' - 0"22' - 0"8' - 0"72' - 0"SHARED BATHROOMMASTER
BEDROOM
KITCHENPANTRYMASTER
BATHROOM
MASTER
CLOSET
BEDROOM #2
BEDROOM #3
DINING
ROOM
MUDROOMW/D13' - 8"6' - 1"13' - 3 1/2"6' - 6"3' - 6"2' - 2"6' - 2 1/2"3' - 1 1/2"4' - 7 1/2"13' - 1 1/2"2' - 1"12' - 2"37' - 6 1/2"5' - 0"3' - 9"9' - 9 1/2"5 1/2"
40' - 0"3' - 0"4' - 9 1/2"2' - 9"5' - 1"4' - 0"68' - 0"4' - 0"19' - 0"21' - 0"8' - 10"3' - 6"2468
10' - 0"12' - 0"11' - 0"17' - 6"18' - 2"3' - 8 1/2"4' - 0"15' - 8 1/2"LIVING
ROOM
FRONT
PORCHDH3050CS2626CS2626DH3060-3W (EGRESS)
T3014
23' - 3"3' - 3 1/2"5' - 9 1/2"9' - 8"8' - 0"4' - 4"
5' - 0"
7' - 0"7' - 0"
CS3040-3W 4' - 0"10' - 0"10' - 2"20' - 10"13' - 0"10' - 0"15' - 2"DH3060-2WDH3060-2WCS3040DH3060DH3060DH3060DH3060 (EGRESS)18' - 0"9' - 3"9' - 5 1/2"2' - 2"8' - 0"7' - 3"3068
EXT30683068PKT-306828683068 SL5068SL50683068
PKT-3068
6068
5068
3068
3068
28682668
3068 EXT30683068
3068
4' - 0"4' - 0"4' - 0"10' - 0"9' - 0"9' - 0"
DH3060 DH3060 DH3060
EXTERIOR
PATIO
3' - 1 1/2"16' - 0"2' - 6 1/2"6' - 6"DROP HEADER5 1/2"5 1/2"13' - 1 1/2"4' - 1 1/2"
4' - 9"
5 1/2"
6' - 10"6' - 0"2' - 1"FIRST FLOOR SQ-FT:
2,093 SQ-FT
WITHOUT GARAGE
40' - 0"
40' - 0"64' - 0"8' - 0"19' - 0"21' - 0"24' - 0"47' - 0"21' - 0"SL301822' - 0"18' - 0"
SL4646
40' - 0"UNFINISHED
BASEMENT
9'-2"
FOUNDATION
WALL PER
CONTRACTOR
EGRESS
WINDOW
SILL (S) NOT TO
BE HIGHER
THAN 44" ABOVE
FLOOR
PERIMETER
FOOTING
DRAIN TO
DAYLIGHT PER
CIVIL DWGS.
(TYP.)
FOUNDATION NOTES:
CONTRACTOR TO COORDINATE WITH CONCRETE
CONTRACTOR FOR SIZE, TYPE & LOCATION OF ALL
REINFORCING IN FOUNDATION WALLS & FOOTINGS.
G4 DESIGN STUDIOS IS NOT RESPONSIBLE FOR
FOUNDATION, FOOTINGS, SLAB & REINFORCING
FINISH GRADING TO BE DETERMINED BETWEEN
OWNER & CONTRACTOR OR CIVIL ENGINEER.SLOPE 1/4” PER 12”INSIDE MIN.3' - 0"4' - 9"17' - 3"
14' - 0"26' - 0"68' - 0"FOOTING SIZED
BY ENGINEER
OR G.C. (TYP.)4' - 0"12' - 0"20' - 0"4' - 4"21' - 8"
PATIO
ABOVE6' - 0"12' - 0"10' - 0"78' - 0"3' - 0"16' - 3"2' - 5"
GARAGE DOOR CUT
COORDINATE
W/ CONTRACTOR
SLAB ON GRADE
SLAB 4" BELOW T.O.
FOUNDATION WALL3' - 10 1/2"10' - 0"3' - 8"17' - 2 1/2"17' - 9 1/2"
WINDOW WELL
BY CONTRACTOR
PER NFPA 101 SEC.
24.2.2.3.3 (4)
CONTRACTOR
TO VERIFY
STAIRS UP
16R @ 7.72" (7.75” MAX)
15T @ 10" (10” MIN)
FOR REVIEW ONLY
NOT FOR CONSTRUCTION
SHEET TITLE:THIS DRAWING IS THE PROPERTY
OF G4 DESIGN STUDIOS, LLC AND
IS NOT TO BE COPIED,
REPRODUCED, OR THE CONTENT
THEREOF USED, IN WHOLE OR IN
PART, WITHOUT THE PRIOR
WRITTEN CONSENT OF STEVE
GUILD
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT:
SHEET SIZE:11/27/2023 10:21:00 AM 3/16" = 1'-0"A101FLOORPLANSDOUSEVICZ
#61 Russet
G4
G4
11/27/23
123VERMONT
ARCH D
24"x36"
3/16" = 1'-0"1 FIRST FLOOR PLAN
3/16" = 1'-0"2BASEMENT
First Floor
412' - 6"
First Floor TP
421' - 7 1/8"
Pre-Con Grade
410' - 0"
6" WHITE BEVEL
HORIZONTAL
SIDING
6" WHITE BEVEL
HORIZONTAL SIDING
4" CORNER TRIM (TYP.)
MATCH COLOR TO SIDING
ASPHALT SHINGLES
1' OVERHANG (TYP.)
DARK RED 12"
BOARD & BATTEN
PLANTER BOX W/ METAL
ANGLE BRACKETS
6" HORIZONTAL
TRIM BOARD
DOUGLAS FIR FINISH
W/ 24" BRACKET
MATCH TRIM
COLOR TO SIDINGFX2020
TO MIDPOINT OF HIGHEST ROOFPEAK17' - 1" +/-First Floor412' - 6"
First Floor TP
421' - 7 1/8"
Pre-Con Grade
410' - 0"
10
12
HD HGT.8' - 0"WINDOW WELL
BY CONTRACTOR
12" +/-
WRAP BOARD & BATTEN
TO MIDPOINT OF HIGHEST ROOFPEAK17' - 1" +/-First Floor
412' - 6"
First Floor TP
421' - 7 1/8"
Pre-Con Grade
410' - 0"
6" WHITE BEVEL SIDINGWRAP BOARD & BATTEN
10
12
8' - 0"First Floor412' - 6"
First Floor TP
421' - 7 1/8"
Pre-Con Grade
410' - 0"
ASPHALT SHINGLES
HD HGT.8' - 0"1' - 0"1' - 0"1' - 0"
WHITE TRIM
WINDOW WELL
BY CONTRACTOR
PER NFPA 101 SEC.
24.2.2.3.3 (4)
FOR REVIEW ONLY
NOT FOR CONSTRUCTION
SHEET TITLE:THIS DRAWING IS THE PROPERTY
OF G4 DESIGN STUDIOS, LLC AND
IS NOT TO BE COPIED,
REPRODUCED, OR THE CONTENT
THEREOF USED, IN WHOLE OR IN
PART, WITHOUT THE PRIOR
WRITTEN CONSENT OF STEVE
GUILD
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT:
SHEET SIZE:11/27/2023 10:21:11 AM 3/16" = 1'-0"A102ELEVATIONSDOUSEVICZ
#61 Russet
G4
G4
11/27/23
123VERMONT
ARCH D
24"x36"
3/16" = 1'-0"1 South
3/16" = 1'-0"2West
3/16" = 1'-0"3East
3/16" = 1'-0"4 North