Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SP-23-032 - Decision - 1200 Airport Drive (4)
Service Base & Pole Size 12NC Description (Diameter x Length x Hook w Bolt Circle Template) Anchor Bolts + Templates For standard shipment with the pole (order 1 per pole) CA or HB & 4"912401597399 AB 3/4x17x3-G DEC w/ 8.5 BC ABT CA or HB & 5"912401613966 AB 3/4x17x3-G DEC w/ 10.5 BC ABT CA & 6"912401613965 AB 1x33x3-G DEC w/ 12.5 BC ABT STB & 4"912401613964 AB 3/4x17x3-G DEC w/ 7 BC ABT STB & 5"912401613107 AB 1x33x3-G DEC w/ 11 BC ABT STB & 6"912401597401 AB 1x33x3-G DEC w/ 12 BC ABT For RapidShip or Pre-Ship service with the pole (order 1 per pole) CA or HB & 4"912401597407 AB 3/4x17x3-G DEC w/ 8.5 BC ABT-RS CA or HB & 5"912401613961 AB 3/4x17x3-G DEC w/ 10.5 BC ABT-RS CA & 6"912401613960 AB 1x33x3-G DEC w/ 12.5 BC ABT-RS STB & 4"912401613959 AB 3/4x17x3-G DEC w/ 7 BC ABT-RS STB & 5"912401613106 AB 1x33x3-G DEC w/ 11 BC ABT-RS STB & 6"912401597408 AB 1x33x3-G DEC w/ 12 BC ABT-RS Family Base3 Pole Size (in.)Wall Thickness (in.) Height (ft.)4 Drilling/Tenon Configuration1 Drilling Template2 Finish Options3 SSA Straight Square Aluminum CA Cast Aluminum Base 4 125 0.125"10 12 15 16 18 20 Drilling BK BZ WH DG MG GY3 SSDGY OC SC5 Black Bronze White Dark Grey Medium Gray Light Grey, Smooth SolarForm Dark Grey (RAL 7011) Optional Color Paint (ex: RAL7024) Special/Custom Color (Specify, must supply color chip) FES5 VDA6 AHH5 DR5 GFI5 VPA CL1/25 CL3/45 CL15 CL1-1/45 CL1-1/25 NL1/25 NL3/45 NL15 NL1-1/45 NL1-1/25 Festoon Outlet Vibration Dampener Additional Hand Hole Duplex Receptacle DR with GFI (120V only) Vandalproof Screws Coupling 1/2" Coupling 3/4" Coupling 1" Coupling 1-1/4" Coupling 1-1/2" Nipple 1/2" Nipple 3/4" Nipple 1" Nipple 1-1/4" Nipple 1-1/2" D1 D1@180 D2 D2@90 D3 D4 1 Way 1 Way @ 180 2 Way @ 180 2 Way @ 90 3 Way @ 90 4 Way @ 90 DT1 DT2 DT3 DT4 DT5 DT6 [DTX-xxx]7 Drill Template 1 Drill Template 2 Drill Template 3 Drill Template 4 Drill Template 5 Drill Template 6 Custom Template HB Hinged Base (max 16', 0.125" only) STB Steel Tenon Base 188 0.188"18 20 30 L/SSS 5 125 0.125"15 16 18 2030 Tenons T2D4L T2D6L T3D4L T4D6L 2-3/8" OD x 4" length 2-3/8" OD x 6" length 3" OD x 4" length 4" OD x 6" length N No DrillingTemplate (for Tenon and Plain Top Options)188 0.188"25 30 30 35 6 188 250 0.188" 0.250"252830 No Drilling/No Tenon P Plain Top Ordering Guide example: SSA-CA-4-125-16-D1-DT5-WH-FES Project: Location: Cat.No: Type: Notes: Site and Area Poles Poles & Brackets Straight Square Aluminum Part No.Description Brackets RLAR-1A-SQ4+ -(finish)Cast Aluminum mounting arm, 15" long with DT6 drill pattern. (order 1 per luminaire). For use with Lumec Roadway and Gardco SolarForm luminaires. Specify finish to match pole. RLAR SSA 1. See Drilling Configurations on Page 2.2. See Luminaire Drilling Templates on Page 2.3. Not all options available with all configurations. Consult factory for more details.4. Pole heights can be cut to length. Specify as a whole number in ft. (ex. 11, 13) or to the inch as a decimal (ex. 15.33 = 15' 4")5. Option must be specified by the customer before order release. FES, DR, GFI, AHH options typically must be placed 12" away from standard hand hole (20" above base).6. VDA is required on all poles equal or greater than 25ft in height.7. Custom drill templates (DTX) require factory quote. Accessories SSA_Spec_Sheet 10/22 page 1 of 9 The Gardco SSA Straight Square Aluminum consists of a single piece of extruded 6000 series aluminum providing excellent strength and integrity. The poles are finished with an electrostatically applied, thermally cured polyester powdercoat. All poles include base cover, hand hole, ground lug and top cap. Anchor bolts and templates are ordered as a separate accessory. SL3 & SL4 POLE/BRACKET SSA_Spec_Sheet 10/22 page 2 of 9 Code Description Luminaires Pole Drilling A To Pole Top B C Full Extent D Wireway Hole E Bolt Hole DT1 Drill Template 1 Gardco SlenderForm Round SFRA 2.25" (57mm)1.5" (38.1mm)3" (76mm)0.875" (22.2mm)0.40" (10.2mm) DT2 Drill Template 2 Gardco SlenderForm Square - SFA Gardco Gullwing - GL13, GL18 Gardco Form Ten - EH14L, EH19L, CAL17, CAL22, MAL17, MAL22 2.25" (57mm)2.17" (55mm)3.84" (98mm)0.875" (22.2mm)0.39" (9.9mm) DT3 Drill Template 3 Gardco PowerForm PFAS 2.25" (57mm)1.75" (44mm)3.84" (98mm)0.875" (22.2mm)0.41" (10.4mm) DT4 Drill Template 4 Gen1 Stonco/Keene AL150-G1, AL200-G1 2.5" (64mm)1.7" (43mm)3.5" (89mm)0.875" (22.2mm)0.41" (10.4mm) DT5 Drill Template 5 Gardco EcoForm Gen2 - ECF-S, ECF-L Gardco PureForm Gen2 - P15, P20, P26, P34 3" (76mm)1" (25mm)3" (76mm)1" (25mm)0.41" (10.4mm) DT6 Drill Template 6 Hole pattern drilled for the following: Gen2 Stonco/Keene AL70-G2 and AL150-G2, or to attach RLAR bracket accessory, suitable for use with: Lumec Capella CPLM, CPLS Lumec RoadStar GPLM, GPLS Lumec RoadFocus RFS, RFM, RFL Lumec RoadView RVM, RVS Lumec MiniView SVS Lumec StreetView SVMGardco SolarForm BRP710 2.5" (64mm)1" (25mm)2" (50mm)0.875" (22mm)0.5" (12.7mm) Ref. access door at 0o for all Drilling Configuration Code Description D1 Single Luminaire D1@180 Single Luminaire @ 180 D2 Two Luminaires @ 180 D2@90 Two Luminaires @ 90 D3 Three Luminaires @ 90 D4 Four Luminaires @ 90 D1@180 D2 D2@90 D3 D4 1 2@902@180 3@90 4@90 0°0°0°0°0° 1 2@902@180 3@90 4@90 0°0°0°0°0° 1 2@902@180 3@90 4@90 0°0°0°0°0° D1 1 2@902@180 3@90 4@90 0°0°0°0°0° 1 2@902@180 3@90 4@90 0°0°0°0°0° Pole Top Drilling E E D A C BHeight Diameter Tenon Diameter Height T2D4L 2.375" (60mm)4" (102mm) T2D6L 2.375" (60mm)6" (152mm) T3D4L 3" (76mm)4" (102mm) T4D6L 4" (102mm)6" (152mm) Tenon Dimensions Poles Straight Square Aluminum Luminaire Drill Pattern Legacy design places access door at 180° NOTE: Factory supplied template must be used when setting anchor bolts. Gardco will not honor any claim for incorrect anchorage placement from failure to use factory supplied templates. * Anchor Bolt Lock Washers are not normally required and are not included in standard anchor bolt sets. They are available upon request at additional cost. ** Grouting should include a drainage slot or tube (by others) to permit water to drain from the base of the pole. Failure to provide drainage may weaken the pole base structure over time and may result in pole base failure, for which Gardco is not responsible. SSA_Spec_Sheet 10/22 page 3 of 9 8' to 30' 20” Anchor Bolts.75” for SSA-CA-4 .75” for SSA-CA-5 1” for SSA-CA-6 Max Bolt Circle 10” for SSA-4 12.5” for SSA-513” for SSA-6 Min Bolt Circle8.5” for SSA-CA-4Ø10.5” for SSA-CA-5Ø12.5” for SSA-CA-6 EPA Based on Nominal Bolt Circle Ø8.5” for SSA-CA-4Ø10.5” for SSA-CA-5Ø12.5” for SSA-CA-6 Each 2x Washers Base Cover View Without Gasket EPDM Door Access Bolt Anchor Each 2x Nuts 2x Captive Screws 2” 4.5” Double Aluminum Ground Lug Screw Ground Lug Base Cover Aluminum Wire Copper 10-7 3.7” for SSA-CA-44” for SSA-CA-55.3” for SSA-CA-6of 3.25”Bolt ProjectionMax. Anchor10.3” for SSA-CA-4 12.3” for SSA-CA-5 13” for SSA-CA-6 Anchor PlateDetail 9.626” for SSA-CA-411.5” for SSA-CA-512.25” for SSA-CA-6Base Cover (not included) Cap Concrete base Door Access Aluminum Round Edges Pole Cap Cap Detail 2x Pressure Screws Poles Straight Square Aluminum Dimensions and Specifications - Cast Aluminum Base SSA_Spec_Sheet 10/22 page 4 of 9 Poles Straight Square Aluminum 10' to 16' Anchor Bolts .75” 10.5” for SSA-HB-5 Nominal Bolt Circle8.5” for SSA-HB-4 Min Bolt Circle8.5” for SSA-HB-49.75” for SSA-HB-5 EPA Based on 10” for SSA-HB-411” for SSA-HB-5 Max Bolt Circle 20" Access Base Cover View Without Door Gasket EPDM Each 2x Nuts nuts to lock hinge mechanism Anchor Bolt Each 2x Washers Captive Screws 2x 4x bolts, washers and Integrated Hinge 2” 4.5” Pole Cap Cap Detail 2x Pressure Screws Anchor PlateDetail 9.7” for SSA-HB-410.7” for SSA-HB-5Wire Copper 10-7 Ground Lug Base Cover Aluminum Double Aluminum Ground Lug Screw 5.081” of 3.5”Max. AnchorBolt Projection 13.5” Base Cover (not included) Cap Concrete base Door Access Aluminum Round Edges 10' to 16' Dimensions and Specifications - Hinged Base SSA_Spec_Sheet 10/22 page 5 of 9 Poles Straight Square Aluminum Dimensions and Specifications - Steel Tenon Base No Min. Max. Only adjustment isradial and varies peranchor plate. Cap Cap Detail Pole 2x Pressure Screws Anchor PlateDetail EPA Based on Nominal Bolt Circle Ø7” for SSA-STB-4 Ø11” for SSA-STB-5 Ø12” for SSA-STB-6 12” for SSA-STB-67.5” for SSA-STB-411” for SSA-STB-5Anchor Bolts Copper 10-7 Wire Base Cover Aluminum Copper Ground Lug Ground Lug Screw 20" 8.25” for SSA-STB-4 12.75” for SSA-STB-6 11.75” for SSA-STB-5 4.125” for SSA-STB-5 & SSA-STB-63.58” for SSA-STB-4Max. AnchorBolt Projectionof 4”Base Cover Cap Aluminum Concrete base Aluminum Edges Round (not included) Access Door Steel Tenon Base Screws Access Door View Without Base Cover EPDM Gasket Anchor 2x Nuts Each Each Bolt 2x Washers 2x Captive 4x Carriage Bolts, Nut and Washer 4.5” 2” Steel Tenon Shim SSA_Spec_Sheet 10/22 page 6 of 9 Poles Straight Square Aluminum Pole Data Pole Specs Anchor Bolt Data Product Catalog Number Pole Diameter (in.)Wall Thickness (in.)Height (ft.) Pole Weight (lbs.) Base Reinforced Bolt Circle (in.) EPA Nominal Bolt Circle (in.) Minimum Bolt Circle (in.) Maxi-mum Anchor Bolt Spec (in.) Anchor Bolt Max Proj. (in.) SSA-CA-4-125-10 4 0.125 10 22 No 8.5 8.5 10 3/4 x 17 x 3 3.25 SSA-CA-4-125-12 4 0.125 12 26 No 8.5 8.5 10 3/4 x 17 x 3 3.25 SSA-CA-4-125-15 4 0.125 15 32 No 8.5 8.5 10 3/4 x 17 x 3 3.25 SSA-CA-4-125-16 4 0.125 16 35 No 8.5 8.5 10 3/4 x 17 x 3 3.25 SSA-CA-4-125-18 4 0.125 18 39 No 8.5 8.5 10 3/4 x 17 x 3 3.25 SSA-CA-4-125-20 4 0.125 20 43 No 8.5 8.5 10 3/4 x 17 x 3 3.25 SSA-CA-4-188-18 4 0.188 18 57 No 8.5 8.5 10 3/4 x 17 x 3 3.25 SSA-CA-4-188-20 4 0.188 20 64 No 8.5 8.5 10 3/4 x 17 x 3 3.25 SSA-CA-5-125-15 5 0.125 15 41 No 10.5 10.5 12.5 3/4 x 17 x 3 3.25 SSA-CA-5-125-16 5 0.125 16 43 No 10.5 10.5 12.5 3/4 x 17 x 3 3.25 SSA-CA-5-125-18 5 0.125 18 49 No 10.5 10.5 12.5 3/4 x 17 x 3 3.25 SSA-CA-5-125-20 5 0.125 20 54 Yes 10.5 10.5 12.5 3/4 x 17 x 3 3.25 SSA-CA-5-188-25 5 0.188 25 105 Yes 10.5 10.5 12.5 3/4 x 17 x 3 3.25 SSA-CA-5-188-30 5 0.188 30 126 Yes 10.5 10.5 12.5 3/4 x 17 x 3 3.25 SSA-CA-6-188-25 6 0.188 25 127 Yes 12.5 12.5 13 1 x 33 x 3 3.25 SSA-CA-6-188-28 6 0.188 28 142 Yes 12.5 12.5 13 1 x 33 x 3 3.25 SSA-CA-6-188-30 6 0.188 30 152 Yes 12.5 12.5 13 1 x 33 x 3 3.25 SSA-CA-6-250-25 6 0.250 25 167 Yes 12.5 12.5 13 1 x 33 x 3 3.25 SSA-CA-6-250-28 6 0.250 28 187 Yes 12.5 12.5 13 1 x 33 x 3 3.25 SSA-CA-6-250-30 6 0.250 30 200 Yes 12.5 12.5 13 1 x 33 x 3 3.25 SSA-HB-4-125-10 4 0.125 10 22 N/A 8.5 8.5 10 3/4 x 17 x 3 3.5 SSA-HB-4-125-12 4 0.125 12 26 N/A 8.5 8.5 10 3/4 x 17 x 3 3.5 SSA-HB-4-125-15 4 0.125 15 32 N/A 8.5 8.5 10 3/4 x 17 x 3 3.5 SSA-HB-4-125-16 4 0.125 16 35 N/A 8.5 8.5 10 3/4 x 17 x 3 3.5 SSA-HB-5-125-15 5 0.125 15 41 N/A 10.5 9.75 11 3/4 x 17 x 3 3.5 SSA-HB-5-125-16 5 0.125 16 43 N/A 10.5 9.75 11 3/4 x 17 x 3 3.5 SSA-STB-4-125-10 4 0.125 10 44 N/A 7 7 7 3/4 x 17 x 3 3.5 SSA-STB-4-125-12 4 0.125 12 51 N/A 7 7 7 3/4 x 17 x 3 3.5 SSA-STB-4-125-15 4 0.125 15 58 N/A 7 7 7 3/4 x 17 x 3 3.5 SSA-STB-4-125-16 4 0.125 16 62 N/A 7 7 7 3/4 x 17 x 3 3.5 SSA-STB-4-125-18 4 0.125 18 67 N/A 7 7 7 3/4 x 17 x 3 3.5 SSA-STB-4-125-20 4 0.125 20 71 N/A 7 7 7 3/4 x 17 x 3 3.5 SSA-STB-4-188-18 4 0.188 18 86 N/A 7 7 7 3/4 x 17 x 3 3.5 SSA-STB-4-188-20 4 0.188 20 93 N/A 7 7 7 3/4 x 17 x 3 3.5 SSA-STB-5-125-15 5 0.125 15 76 N/A 11 11 11 1 x 33 x 3 3.5 SSA-STB-5-125-16 5 0.125 16 82 N/A 11 11 11 1 x 33 x 3 3.5 SSA-STB-5-125-18 5 0.125 18 88 N/A 11 11 11 1 x 33 x 3 3.5 SSA-STB-5-125-20 5 0.125 20 94 N/A 11 11 11 1 x 33 x 3 3.5 SSA-STB-5-125-25 5 0.125 25 112 N/A 11 11 11 1 x 33 x 3 3.5 SSA-STB-5-125-30 5 0.125 30 130 N/A 11 11 11 1 x 33 x 3 3.5 SSA-STB-5-188-25 5 0.188 25 146 N/A 11 11 11 1 x 33 x 3 3.5 SSA-STB-5-188-30 5 0.188 30 171 N/A 11 11 11 1 x 33 x 3 3.5 SSA-STB-6-188-25 6 0.188 25 174 N/A 12 12 12 1 x 33 x 3 4 SSA-STB-6-188-28 6 0.188 28 194 N/A 12 12 12 1 x 33 x 3 4 SSA-STB-6-188-30 6 0.188 30 204 N/A 12 12 12 1 x 33 x 3 4 SSA-STB-6-250-25 6 0.250 25 215 N/A 12 12 12 1 x 33 x 3 4 SSA-STB-6-250-28 6 0.250 28 239 N/A 12 12 12 1 x 33 x 3 4 SSA-STB-6-250-30 6 0.250 30 253 N/A 12 12 12 1 x 33 x 3 4 SSA_Spec_Sheet 10/22 page 7 of 9 Poles Straight Square Aluminum © 2018 Signify Holding All rights are reserved. Reproduction in whole or part is prohibited without the written consent of the copyright owner. © 2018 Signify Holding Tous droits réservés. La reproduction complète ou partielle de ce document est interdite sans une autorisation écrite du titulaire des droits d'auteur THIRD ANGLE PROJECTION B A C D E 134 4 3 2 1 A B C D E Assy Typical AnchorPOUCES/DRWING #: TITRE/TITLE: NO DESSIN/ PART/ASS. #:NO PIÈCE/ASS. / SHEET:FEUILLE/ SCALE: POIDS/WEIGHT:DATE: 1:4 DESSINÉ/DESIGNER: 1 DE 2 ÉCHELLE/ MATERIAL:MATÉRIAU/ UNITS: VÉRIF./INSPEC.: DATE: APPROUVÉ: DATE: * NE PAS MODIFIER L'ÉCHELLE DU DESSIN - DO NOT SCALE THIS DRAWING * UNITÉS/ ALL THREADS ARE UNC-2B OR UNF-2B AFTER COATING, VERIFIED WITH A GAGE DOCUMENT CONTRÔLÉ Vérifiez écran du système ERP pour dernière révision - CONTROLLED DOCUMENT Check ERP system screen for latest revision TOUS FILETS SONT UNC-2B OU UNF-2B APRÈS REVÊTEMENT, VÉRIFIÉS AVEC UN GABARIT -SIZE:A 2 TAILLE/ INCHES 0.3918 Assy Typical Anchor EF 03/22/2021PROJECTION AMÉRICAINE Standardized Anchor Bolt HEX NUTS - GRADE AASTM A563 (see tableon page 2 for qty) WASHERS TYPE AGRADE 2 - ASTM A307 (see table on page 2 for qty) Ø Ø L H table on page 2 R Washer OD andThickness, see LT RÉV DESCRIPTION DATE PAR/BY 1 Added "W" in table on page 2 2021-03-24 EF MATERIAL SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD SPECIFICATION FOR STEEL ANCHOR BOLTS (AASHTO M 314 90) OR THE AMERICAN SOCIETY FOR TESTING MATERIALS (ASTM) HAVING 55 KSI (GRADE 55) YIELD STRENGTH AND 75-95 KSI TENSILE STRENGTH, ASTM F1554. FULLY GALVANIZED; GALVANIZATION PROCESS MUST BE IN ACCORDANCE WITH AMERICAN STANDARD ASTMA-153.6 C1.C WARNING: THREADS MUST BE FREE OF EXCESS ZINC AND MUST ACCEPT GALVANIZED OVERSIZE NUTS Example: 3/4-10 x 16.25 x 3 - t3.5 - r1 (see table on page 2 for other sizes)Ø - Threads/in L H LT R Generic Description 3/4-10 16.25 3 3.5 1 3/4-10 x 17 x 3 Per Example inTable Below 16.25 1 3 3.5 Ø 0.753/4-10 UNC Ø 0.75 HEX NUTS -Grade AASTM A563 Washers Type A Grade 2 - ASTM A307 Standard Anchor Bolt 1. Warning: Additional wind loading, in terms of EPA, from banners, cameras, floodlights and other accessories attached to the pole, must be added to the luminaire(s) EPA before selecting the pole with the appropriate wind load capability. Specifying BAA or BAC compliant poles may result in different EPA ratings. 2. Factory supplied template must be used when setting anchor bolts. Gardco will not honor any claim for incorrect anchorage placement resulting from failure to use factory supplied templates. Exact length of anchor bolts may vary. 3. EPA ratings are based on the listed, optimal midpoint of the bolt circle. The bolt circle has limited variability but the EPA rating will change. EPA Table AASHTO 2001 - EPA ft2 Product Catalog Number 80 MPH 90 MPH 100 MPH 110 MPH 120 MPH 130 MPH SSA-CA-4-125-10 12.44 9.30 7.07 5.41 4.14 3.16 SSA-CA-4-125-12 9.55 6.91 5.02 3.62 2.56 1.73 SSA-CA-4-125-15 6.32 4.17 2.66 1.54 0.66 N/A SSA-CA-4-125-16 5.41 3.39 1.97 0.92 0.12 N/A SSA-CA-4-125-18 3.69 1.97 0.76 N/A N/A N/A SSA-CA-4-125-20 2.26 0.76 N/A N/A N/A N/A SSA-CA-4-188-18 8.04 5.51 3.69 2.32 1.34 0.52 SSA-CA-4-188-20 6.19 3.98 2.36 1.18 0.27 N/A SSA-CA-5-125-15 11.17 7.79 5.35 3.55 2.17 1.11 SSA-CA-5-125-16 9.84 6.62 4.37 2.67 1.39 0.37 SSA-CA-5-125-18 7.30 4.51 2.51 1.05 N/A N/A SSA-CA-5-125-20 5.15 2.71 0.95 N/A N/A N/A SSA-CA-5-188-25 6.42 3.53 1.48 N/A N/A N/A SSA-CA-5-188-30 2.22 N/A N/A N/A N/A N/A SSA-CA-6-188-25 10.97 6.75 3.73 1.50 N/A N/A SSA-CA-6-188-28 7.34 3.65 1.05 N/A N/A N/A SSA-CA-6-188-30 5.21 1.83 N/A N/A N/A N/A SSA-CA-6-250-25 17.78 12.28 8.34 5.44 3.20 1.48 SSA-CA-6-250-28 13.45 8.67 5.21 2.67 0.76 N/A SSA-CA-6-250-30 10.96 6.52 3.39 1.05 N/A N/A SSA-HB-4-125-10 12.44 9.30 7.07 5.41 4.14 3.16 SSA-HB-4-125-12 9.55 6.91 5.02 3.62 2.56 1.73 SSA-HB-4-125-15 6.32 4.17 2.66 1.54 0.66 N/A SSA-HB-4-125-16 5.41 3.39 1.97 0.92 0.12 N/A SSA-HB-5-125-15 11.17 7.79 5.35 3.55 2.17 1.11 SSA-HB-5-125-16 9.84 6.62 4.37 2.67 1.39 0.37 SSA-STB-4-125-10 24.90 19.30 15.20 12.30 10.02 8.27 SSA-STB-4-125-12 21.00 16.15 12.65 10.07 8.10 6.60 SSA-STB-4-125-15 11.90 8.80 6.55 4.90 3.62 2.65 SSA-STB-4-125-16 11.60 8.55 6.35 4.75 3.50 2.55 SSA-STB-4-125-18 8.55 6.05 4.25 2.90 1.90 1.10 SSA-STB-4-125-20 6.10 4.00 2.50 1.38 0.53 N/A SSA-STB-4-188-18 14.90 11.10 8.40 6.45 4.93 3.65 SSA-STB-4-188-20 11.60 8.40 6.15 4.50 3.23 2.25 SSA-STB-5-125-15 24.30 18.40 14.15 11.00 8.65 6.78 SSA-STB-5-125-16 20.00 15.00 11.40 8.75 6.70 5.15 SSA-STB-5-125-18 15.40 11.20 8.25 6.05 4.35 3.05 SSA-STB-5-125-20 11.75 8.20 5.70 3.80 2.40 1.28 SSA-STB-5-125-25 5.75 3.25 1.40 0.05 N/A N/A SSA-STB-5-125-30 1.15 3.72 1.54 N/A N/A N/A NOTE: Above EPA (Effective Projected Area) rating is in accordance with AASHTO 2001 and CSA-S6-14, with a 50 pound load (22.7 kg) placed at 1 foot (305mm) above its center. AASHTO 2001 - EPA ft2 Product Catalog Number 80 MPH 90 MPH 100 MPH 110 MPH 120 MPH 130 MPH SSA-STB-5-188-25 12.60 8.70 6.00 3.95 2.40 1.18 SSA-STB-5-188-30 6.65 3.80 1.75 0.25 N/A N/A SSA-STB-6-188-25 20.70 14.80 10.60 7.50 5.15 3.30 SSA-STB-6-188-28 16.10 11.10 7.45 4.75 2.70 1.15 SSA-STB-6-188-30 12.60 8.10 4.90 2.55 0.75 N/A SSA-STB-6-250-25 25.90 18.70 13.60 9.80 6.90 4.70 SSA-STB-6-250-28 20.70 14.40 9.90 6.60 4.10 2.19 SSA-STB-6-250-30 17.70 11.89 7.79 4.70 2.40 0.60 EPA Table (Cont.) SSA_Spec_Sheet 10/22 page 8 of 9 Poles Straight Square Aluminum EPA Table CSA-S6-14 - EPA ft2 Product Catalog Number 300 Pa79 MPH 400 Pa91 MPH 400 Pa102 MPH 600 Pa111 MPH 700 Pa120 MPH 800 Pa129 MPH SSA-CA-4-125-10 7.50 4.98 3.49 2.46 1.73 1.21 SSA-CA-4-125-12 5.35 3.22 1.93 1.11 0.50 0.04 SSA-CA-4-125-15 2.83 1.15 0.11 N/A N/A N/A SSA-CA-4-125-16 2.12 0.52 N/A N/A N/A N/A SSA-CA-4-125-18 0.82 N/A N/A N/A N/A N/A SSA-CA-4-125-20 N/A N/A N/A N/A N/A N/A SSA-CA-4-188-18 3.45 1.39 0.13 N/A N/A N/A SSA-CA-4-188-20 2.03 0.17 N/A N/A N/A N/A SSA-CA-5-125-15 5.93 3.20 1.57 0.46 N/A N/A SSA-CA-5-125-16 4.92 2.35 0.82 N/A N/A N/A SSA-CA-5-125-18 3.06 0.80 N/A N/A N/A N/A SSA-CA-5-125-20 1.44 N/A N/A N/A N/A N/A SSA-CA-5-188-25 1.40 N/A N/A N/A N/A N/A SSA-CA-5-188-30 N/A N/A N/A N/A N/A N/A SSA-CA-6-188-25 4.47 0.82 N/A N/A N/A N/A SSA-CA-6-188-28 1.54 N/A N/A N/A N/A N/A SSA-CA-6-188-30 N/A N/A N/A N/A N/A N/A SSA-CA-6-250-25 8.96 4.17 1.29 N/A N/A N/A SSA-CA-6-250-28 5.51 1.25 N/A N/A N/A N/A SSA-CA-6-250-30 3.44 N/A N/A N/A N/A N/A SSA-HB-4-125-10 7.50 4.98 3.49 2.46 1.73 1.21 SSA-HB-4-125-12 5.35 3.22 1.93 1.11 0.50 0.04 SSA-HB-4-125-15 2.83 1.15 0.11 N/A N/A N/A SSA-HB-4-125-16 2.12 0.52 N/A N/A N/A N/A SSA-HB-5-125-15 5.93 3.20 1.57 0.46 N/A N/A SSA-HB-5-125-16 4.92 2.35 0.82 N/A N/A N/A SSA-STB-4-125-10 28.00 20.60 16.05 13.05 10.90 9.30 SSA-STB-4-125-12 23.18 16.82 12.99 10.42 8.63 7.26 SSA-STB-4-125-15 16.32 11.46 8.53 6.58 5.19 4.17 SSA-STB-4-125-16 16.32 11.46 8.53 6.58 5.19 4.17 SSA-STB-4-125-18 13.00 8.85 6.30 4.65 3.45 2.55 SSA-STB-4-125-20 10.25 6.60 4.43 2.98 1.95 1.17 SSA-STB-4-188-18 16.90 11.50 8.25 6.10 4.55 3.38 SSA-STB-4-188-20 13.80 9.00 6.15 4.25 2.90 1.85 SSA-STB-5-125-15 27.07 19.31 14.67 11.60 9.35 7.69 SSA-STB-5-125-16 27.07 19.31 14.67 11.60 9.35 7.69 SSA-STB-5-125-18 22.14 15.44 11.43 8.76 6.84 5.41 SSA-STB-5-125-20 18.17 12.28 8.76 6.42 4.75 3.49 SSA-STB-5-125-25 11.60 7.00 4.25 2.40 1.10 0.12 SSA-STB-5-125-30 6.35 2.70 0.55 N/A N/A N/A SSA-STB-5-188-25 20.20 13.07 8.80 5.95 3.90 2.35 SSA-STB-5-188-30 12.50 6.80 3.40 1.15 N/A N/A SSA-STB-6-188-25 31.80 21.30 15.00 10.80 7.85 5.65 SSA-STB-6-188-28 26.30 16.90 11.20 7.45 4.80 2.85 SSA-STB-6-188-30 22.90 14.20 8.90 5.35 2.90 1.00 SSA-STB-6-250-25 28.00 18.50 12.75 8.95 6.25 4.20 SSA-STB-6-250-28 21.80 13.50 8.50 5.25 2.85 1.10 SSA-STB-6-250-30 18.00 10.50 6.00 2.90 0.75 N/A Poles Straight Square Aluminum Pole shaft The pole shaft is fabricated from a single piece of extruded 6000 series aluminum. Shaft includes factory installed copper ground lug, 10-7 wire, and ground lug screw. A vibration dampener (VDA) is automatically added by the factory for all poles 25ft or higher. Anchor Base The pole anchor base consists of a cast aluminum base welded to the shaft (CA), a cast aluminum hinged base (HB) or a steel tenon base (STB) secured with bolts and shims in which the aluminum shaft is slipped over. Anchor Bolts Anchor bolts are fabricated from a commercial quality hot rolled carbon steel bar that meets or exceeds a minimum guaranteed yield strength of 55 ksi. Bolts have an “L” bend on one end and threaded on the opposite end. Anchor bolts are galvanized in accordance with ASTM A-153.6 C1.C. Four (4) properly sized bolts, each furnished with two (2) regular hex nuts and two (2) flat washers, are provided per pole (priced and ordered separately), unless otherwise specified. Conforms to AASHTO M 314 90 and ASTM F1554. Customer Specified Options The options, DTX, FES, DR, GFI, AHH, CL*, and NL* require factory quotation. Poles with custom drilling templates (DTX) are provided as a service, however Signify holds no liability for improper installation and safety when using non-Signify luminaires or attachments on Gardco poles via drilling, tenon mounting, or coupling and nipple mounting. It is the responsibility of the customer to ensure the pole is loaded and installed in a safe manner to the limitations of the pole structure. See "Warning" paragraph for more details. Base CoverA two-piece painted square aluminum base cover that completely conceals the entire base plate and anchorage. Base cover is provided standard. Hand holeThe hand hole has a nominal rectangular 2”x4.5" inside opening in the pole shaft. Included is an aluminum cover plate, EPDM gasket, and captive attachment screws. The hand hole is located 20” above the base and 0° clockwise with respect to the luminaire arm when viewed from the top of the pole for one arm. For two arms the hand hole is located directly under one arm. Pole Top Cap Each pole assembly is provided with a removable aluminum pole top cap painted to match the specified pole and attached with two pressure screws. Finish Poles are available with Gardco's standard textured color finishes - Black, White, Bronze, Dark Grey, Medium Grey, and Lumec GY3 for a match with roadway luminaire finishes. Optional custom colors also available. Couplings and Nipples Couplings (NPSC standard internal threads) and Nipples (NPT standard external threads) are available to mount 3rd party objects to the pole. Lengths are as follows: Couplings < 1" dia. = 1" lengthCouplings >= 1" dia. = 1.5" lengthNipples < 1" dia. = 1.5" lengthNipples >= 1" dia. = 2" length See "Customer Specified Options" paragraph for more details. Duplex Receptacle (DR and GFI) DR and GFI options are placed at 2' below the pole top on the same side as the hand hole unless otherwise specified. DR or GFI options cannot be placed within 1' of the the hand hole. Maximum output of the receptacles are 15A. Design EPA specs conform to AASHTO 2001 and CSA-S6-14 standards. The poles as charted are designed to withstand dead loads and predicted dynamic loads developed by variable wind pressure with an additional 2.5 gust factor under the following conditions: The charted weights include luminaire(s) and/or mounting bracket(s). Poles installed in areas of known abnormal conditions may require special consideration. For example: coastal areas, airports and areas of special winds. Poles are designed for ground mounted applications. Poles mounted on structures (such as buildings and bridges) may also necessitate special consideration requiring Gardco’s recommendation. Height correction factors and drag coefficients are applied to the entire structure. An appropriate safety factor is maintained based on the minimum yield strength of the material incorporated in the pole. Warning This design information is intended as a general guideline only. The customer is solely responsible for proper selection of pole, luminaire, accessory and foundation under the given site conditions and intended usage. The addition of any items to the pole, in addition to the luminaire, will dramatically impact the EPA load on that pole. It is strongly recommended that a qualified professional be consulted to analyze the loads given the user’s specific needs to ensure proper selection of the pole, luminaire, accessories, and foundation. Gardco assumes no responsibility for such proper analysis or product selections. Failure to ensure proper site analysis, pole selection, loads and installation can result in pole failure, leading to serious injury or property damage. Warranty Gardco Aluminum poles are covered by a 5-year and finish warranty. Legacy designs are covered by a 1-year warranty. For more information visit signify.com/warranties Specifications General Pole Information FILENAME HERE XX/2019SSA_Spec_Sheet 10/22 page 9 of 9 © 2022 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify. SSA_Spec_Sheet 10/22 page 9 of 9 Signify North America Corporation 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807 Telephone 855-486-2216 Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3 Telephone 800-668-9008 All trademarks are owned by Signify Holding or their respective owners. www.gardcolighting.com