HomeMy WebLinkAboutZP-23-313 - 0096 Aurora Road 9/13/2023ZP-23-313
ADMIN OFFICER CORRECTION : #96xx
09/08/2023
1/2 of duplex
1,540.75 SEQ NR
SD-18-28 11/26/2018
09/13/2023
09/12/202309/28/2023
(Acting)
Property Owners Name:JJJ South Burlington
Property Location:96 Aurora Road
Amount:15,422.57 Payment Type:check #0738 Date:8/17/2023
Code
Zoning Permit (New Residential)ZP-23-313 zp Recording fee 13.00$
plus
2689 0.45$ per sq. ft. 1,210.05$
plus
1255 0.20$ per sq. ft. 251.00$
plus
2 50.00$ per bay 100.00$
plus
After-the fact of 50% [no NOV] or 100% [NOV] -$
Zoning Permit Total 1,574.05$
Sewer Allocation Fee WWA-23-150 #204 234.52 g.p.d x 14.57$ 3,416.96$
Bartlett Bay
x Airport Parkway
Impact Fee Administration Fee #248 100.00$ per application 100.00$
School Impact Fee #222S 6,061.35$
Recreation Impact Fee #220 -$
South Village Recreation Impact Fee #243 1,665.08$ per unit 1,665.08$
Road Impact Fee #221 635.76$ per unit 635.76$
Cider Mill Impact Fee* *See #SD-18-28 #213 1,000.00$ per unit 1,000.00$
Fire Impact Fee #203 -$
Police Impact Fee #222 496.08$ per unit 496.08$
Dorset Street Waterline Fee #230 410.29$
Sewer Connection Inspection WW-23-51 ww 63.00$ per connection 63.00$
Total (Impact Fees + Permit) 15,422.57$
Planning & Zoning Invoice
Residential Impact & Permit Fees
garage bay(s) at
Amount Due
sq. ft building at
sq. ft unfinished basement at
First Floor
408' - 0"
First Floor TP
417' - 1 1/8"
Second Floor
418' - 1 1/8"
Second Floor TP426' - 2 1/4"8' - 1 1/8"1' - 0"9' - 1 1/8"9' - 0"10"
12"
10"
12"
3:12 PITCH STANDING
SEAM ROOF
7.5:12 SLOPE7.5:12 SLOPE
10"
12"
10"
12"
Pre-Con Grade
406' - 0"25' - 0 3/4" BUILDING HGT.First Floor408' - 0"
First Floor TP
417' - 1 1/8"
Second Floor
418' - 1 1/8"
Second Floor TP
426' - 2 1/4"
Basement Slab
397' - 9 1/2"
Top of Foundation
406' - 10 1/2"1' - 1 1/2"9' - 1 1/8"1' - 0"8' - 1 1/8"10"
12"
10"
12"
7.5:12 SLOPE
10"
12"
10"
12"
Pre-Con Grade
406' - 0"25' - 0 3/4" BUILDING HGT.First Floor408' - 0"
First Floor TP
417' - 1 1/8"
Second Floor
418' - 1 1/8"
Second Floor TP
426' - 2 1/4"
Top of Foundation406' - 10 1/2"
3"
12"
7 1/2"
12"
6"
12"
Pre-Con Grade
406' - 0"
First Floor
408' - 0"
First Floor TP
417' - 1 1/8"
Second Floor
418' - 1 1/8"
Second Floor TP426' - 2 1/4"
Top of Foundation
406' - 10 1/2"
3"
12"
7 1/2"
12"
6"
12"
Pre-Con Grade
406' - 0"
SHEET TITLE:THIS DRAWING IS THE PROPERTY
OF G4 DESIGN STUDIOS, LLC AND
IS NOT TO BE COPIED,
REPRODUCED, OR THE CONTENT
THEREOF USED, IN WHOLE OR IN
PART, WITHOUT THE PRIOR
WRITTEN CONSENT OF STEVE
GUILD
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT:9/6/2023 10:56:23 AM 3/16" = 1'-0"A-4EXTERIOR
ELEVATIONSUnit #109, #110
96, 98 Aurora Road
G4
G4
7/18/23
EDGE WD.SOUTH BURLINGTON, VERMONT
OPTION
#1B
3/16" = 1'-0"1FRONT ELEVATION
3/16" = 1'-0"2REAR ELEVATION
3/16" = 1'-0"4 LEFT ELEVATION
3/16" = 1'-0"3 RIGHT ELEVATION
45' - 0"2' - 0"18' - 6 1/2"21' - 5 1/2"21' - 5 1/2"18' - 6 1/2"
19' - 0"20' - 7"10"20' - 7"19' - 0"
14' - 3"3' - 5"12' - 6"5' - 0"2' - 0"22' - 0"25' - 0"2' - 0"10' - 0"8' - 4"21' - 8"21' - 8"8' - 4"10' - 0"
GARAGE SLAB
ON GRADE
OPEN BASEMENT
UNFINISHED
SPACE
GARAGE SLAB
ON GRADE
OPEN BASEMENT
UNFINISHED
SPACE
PORCH ABOVE PORCH ABOVE
5'x7' MECH.
DUCTWORK
CLOSET W/
DOOR
7'-11"x7'-6"
MECHANICAL
ROOM W/ 2x4
WALLS & DOOR
5'x7' MECH.
DUCTWORK
CLOSET W/
DOOR
7'-11"x7'-6"
MECHANICAL
ROOM W/ 2x4
WALLS & DOOR
30683068
(4) PRECAST
PORCH PIERS
(4) PRECAST
PORCH PIERS
UTILITIES
COMING FROM
STREET IN THIS
APPROX. LOCATION
UTILITIES
COMING FROM
STREET IN THIS
APPROX. LOCATION
CONSTRUCTION NOTES:
10" THICK x 20" WIDE TYPICAL FOOTING
8" THICK, 9'-2" TALL FOUNDATION WALLS
BASEMENT TO HAVE TWO MECHANICAL
ROOMS AS SHOWN - GWB FINISH ON EXTERIOR
OF MECHANICAL ROOM WALLS
BASEMENT WALL INSULATION = R21 3" POLYISO
INSULATION BOARD (SAME AS STREAMSIDE)
(1) BILCO EGRESS WELL PER UNIT
BASEMENT IS UNFINISHED
BASEMENT STAIRS ARE UNFINISHED
RADON PIPE UNDERSLAB BY PLUMBING TRADE
ALL ESCAPE WINDOW SILLS SHALL NOT BE MORE THAN 44"
3' - 5"14' - 3"8' - 0"45' - 0"8' - 0"CONTRACTOR TO VERIFY
STAIRS UP
16R @ 7.28"
15T @ 10"
CONTRACTOR TO VERIFY
STAIRS UP
16R @ 7.28"
15T @ 10"
19' - 0"8' - 0"19' - 0"
17' - 0"17' - 0"2' - 0"DECK ABOVE
(AT GRADE)
DECK ABOVE
(AT GRADE)
9' - 5 1/2"12' - 0"12' - 0"9' - 5 1/2"
EGRESS4646 EGRESS46468' - 0"5' - 9 1/2"5' - 9 1/2"7' - 4 1/2"16' - 8"GARAGE DOOR CUTS
ADDITIONAL
1-1/2" ON EA. SIDE
FOR FRAMING
2' - 7"16' - 3"2' - 10"2' - 7"16' - 3"2' - 10"
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT:
SHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILD 1/4" = 1'-0"9/6/2023 10:56:07 AMA-1
BASEMENT
PLANUnit #109, #11096, 98 Aurora RoadG4
G4
7/18/23
EDGE WD.SOUTH BURLINGTON, VERMONTOPTION
#1B
1/4" = 1'-0"1BASEMENT PLAN
DINING
HARDWOOD
KITCHEN
HARDWOOD
LIVING
HARDWOOD
MASTER
BATH
TILE
PANTRYCLOSETENTRY
HARDWOOD
COVERED PORCH
COMPOSITE DECKING
OPEN DECK
COMPOSITE DECKING
DINING
HARDWOOD
KITCHEN
HARDWOOD
LIVING
HARDWOOD
MASTER
BATH
TILE
PANTRYCLOSETENTRY
HARDWOOD
COVERED PORCH
COMPOSITE DECKING
OPEN DECK
COMPOSITE DECKING
DH3060CSF4046DH3060DH306030683068
2668
3068
CS3040DH3060-2W
DH3060CSF4046DH3060DH30603068
2668
2668
3068
CS3040 DH3060-2W
306816' x 8' O.H.D.16' x 8' O.H.D.
17' - 0"46' - 0"17' - 0"
4' - 1 3/8"9 1/4"4' - 1 3/8"5' - 0"8' - 6 1/2"5' - 0"
80' - 0"
DH3060-2W DH3060-2W6' - 5 1/2"2' - 0"8' - 0"3' - 8"5' - 11"3' - 3"22' - 6 1/2"TWO CAR
GARAGE
TWO CAR
GARAGE
2' - 4 1/2"3' - 8"3' - 8"CLST.W.I.C.
CARPET
MUDROOM
TILE
BENCH
HALLWAY
TILE21068266830682668
3068CLST.W.I.C.
CARPET
MUDROOM
TILE
BENCH
HALLWAY
TILE 210682668
30682668
30683068 3068VSB30 VSB30GAS & ELEC.
WASH/DRY
TILE
GAS & ELEC.
WASH/DRY
TILE
CONSTRUCTION NOTES:
2x6 EXTERIOR WALLS R12
ZIP SHEATHING
R21 EXTERIOR WALL INSULATION
R21 CLOSED CELL FOAM AT BOX
PLATES R60 ATTIC INSULATION
R30 FLOOR INSULATION
SOUND PROOFING ACOUSTICAL
INSULATION AT WALL BETWEEN
DUPLEX UNITS
FLOOR FINISHES AS INDICATED
ON PLANS
DOOR AND WINDOW SIZES AS
INDICATED ON PLANS
KITCHEN APPLIANCE PACKAGE
WILL BE SAME AS TYPICAL
STREAMSIDE PACKAGE
GAS CONNECTION FOR WASHER
GAS CONNECTION FOR RANGE/OVEN
GARAGE DOOR TYPICAL OF STREAMSIDE
HARVEY WINDOWS WITH BLACK
EXTERIOR, WHITE INTERIOR TYPICAL
OF STREAMSIDE
EXTERIOR DOORS ARE THERMATRU
FIBERGLASS, TYPICAL OF STREAMSIDE
CLASSIC GRANITE COUNTER-TOPS,
TYPICAL OF STREAMSIDE
KITCHEN CABINETS TYPICAL
OF STREAMSIDE
(MID CONTIGENT SIGNATURE SERIES)
CULTURED MARBLE TOPS FOR BATHROOM
VANITIES
1/2 BATH TO HAVE BATH VANITY
MASTER BATH SHOWER TO HAVE
FIBERGLASS SHOWER PAN, TILE SURROUND,
GLASS DOORS, TYPICAL OF STREAMSIDE
ALL CLOSETS TO HAVE WHITE WIRE
SHELVING
LIGHT FIXTURES TYPICAL OF STREAMSIDE
MECHANICAL SYSTEM TYPICAL
OF STREAMSIDE (YORK LX FURNACE, YORK
CONDENSER, BRADFORD 50 GAL WATER HEATER)
PLUMBING FIXTURES TYPICAL OF STREAMSIDE 8' - 0"3' - 0"10' - 0"14' - 0"11' - 6"6' - 6"8' - 0"8' - 0"3' - 0"10' - 0"14' - 0"11' - 6"6' - 6"8' - 0"2668
S6068DH3060S6068DH3060
5' - 0"8' - 6 1/2"5' - 0"9' - 5 1/2"7' - 6"9' - 5 1/2"7' - 6"6' - 5 1/2"2' - 0"8' - 0"5' - 11"3' - 3"22' - 6 1/2"2' - 4 1/2"3' - 8"20' - 7 3/8"9 1/4"20' - 7 3/8"22' - 0"22' - 0"5' - 0"5' - 0"8' - 6 1/2"5' - 0"5' - 0"8' - 6 1/2"
5' - 6"3' - 8"
3' - 9"4' - 5 3/8"2' - 1"11' - 11 1/2"5' - 6"3' - 8"
3' - 9"4' - 5 3/8"11' - 11 1/2"2' - 1"3' - 6"6' - 0"14' - 5 1/2"1/2 BATH
TILE
3' - 6"6' - 0"14' - 5 1/2"1/2 BATH
TILE
6' - 0"6' - 0"45' - 0"CONTRACTOR TO VERIFY
STAIRS UP
16R @ 7.57"
15T @ 10"
CONTRACTOR TO VERIFY
STAIRS UP
16R @ 7.57"
15T @ 10"
11' - 11"11' - 11"
REQUIREMENTS PER SO. BURLINGTON FIRE MARSHALL
1. ANY FIRE, SMOKE BARRIERS, AND INTERIOR FINISHES
WILL BE MAINTAINED, RECONSTRUCTED OR INSTALLED
PER IBC AND NFPA REQUIREMENTS FOR THE OCCUPANY USE
GROUP (NFPA 1). ALL PENETRATIONS BETWEEN FLOORS,
ATTICS, AND /OR BASEMENTS SHALL BE FIRE STOPPED
WITH FIRE/SMOKE PENETRATION CAULKING/SEALANTS
SHALL BE RED IN COLOR FOR EASE OF IDENTIFICATION.
ALL FIRE WALLS AND SMOKE BARRIERS SHALL BE CLEARLY
STENCILED ABOVE THE CEILING PURSUANT TO IBC AND
NFPA REQUIREMENTS. FOAM FIRE BLOCKING IS PROHIBITED
2. IF THE BASEMENT IS TO BE FINISHED, THE FURNACE AREA
SHALL BE PROTECTED BY SEPARATE FIRE RATED COMPARTMENT
(CEILING INCLUDED), OR BY LIMITED AREA SPRINKLER HEAD
OVER/BY APPLIANCE, INSTALLED BY LICENSED PROFESSIONAL
3. THE BACKSIDE OF BASEMENT STAIRS AND LANDING(S) SHALL
BE PROTECTED BY 5/8" SHEETROCK AND TAPED WITH A MINIMUM
OF ONE COAT.
4. ALL ESCAPE WINDOW SILLS SHALL NOT BE MORE THAN 44"
5. PHOTO SMOKE/CO2 DETECTORS SHALL BE INSTALLED PER
SBFPFSO, AND BE HARD WIRED, INTERCONNECTED TO ALL
DETECTION WITHIN THE DWELLING UNIT
6. SERVICE DOORS FROM DWELLING TO GARAGE SHALL BE
A MINIMUM OF A 45 MINUTE FIRE-RATED DOOR WITH A
SELF-CLOSING/LATCHING DOOR LEAF
7. ALL ELECTRICAL REQUIRES A SEPERATE SUB TRADE WORK
PERMIT/WORK NOTICE ISSUED BY THE SBFD ELECTRICAL
INSPECTOR. ALL ELECTRICAL TRADES PERSONS SHALL HAVE
VALID STATE ELECTRICAL LICENSES
8. ALL PLUMBING WORK REQUIRES A SEPERATE SUB TRADE WORK
PERMIT/WORK NOTICE ISSUED BY DFS-WILLISTON.
ALL PLUMBING TRADES PERSONS SHALL HAVE VALID STATE
PLUMBING LICENSES
9. CONSTRUCTION DUMPSTER(S) SHALL BE LOCATED A MINIMUM
OF 10 FEET FROM ANY COMBUSTIBLE OR OPEN SURFACE OF THE
BUILDING. DUMPSTERS SHALL NOT OBSTRUCT EGRESS
10. NO SMOKING IS ALLOWED WITHIN 10 FEET OF THE BUILDING
11. THE BUILDING SHALL BE IN COMPLIANCE WITH NFPA 241
DURING CONSTRUCTION
12. THE BUILDING SHALL ADDRESS NUMBERS PLACED IN A POSITION
TO BE PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY. THE NUMBERS SHALL BE IN HIGH CONTRAST
WITH THEIR BACKGROUND PER NFPA 1 (2015) AND THE CITY ORDINANCES
13. A 1A-10BC FIRE EXTINGUISHER SHALL BE INSTALLED IN THE KITCHEN
IN PLAIN VIEW.
UL# V324 1HR FIRE RATED
WALL ASSEMBLY
MASTER
BEDROOM
HARDWOOD
MASTER
BEDROOM
HARDWOOD
HW
STAIRS
HW
STAIRSFIREPLACE5' - 0"5' - 6"FIREPLACE5' - 0"5' - 6"3' - 8"1' - 6"1' - 6"
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT:
SHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILD 1/4" = 1'-0"9/6/2023 10:56:10 AMA-2
FIRST
FLOOR PLANUnit #109, #11096, 98 Aurora RoadG4
G4
7/18/23
EDGE WD.SOUTH BURLINGTON, VERMONTOPTION
#1B
1/4" = 1'-0"1FIRST FLOOR PLAN
BEDROOM #3
CARPET
W.I.C.
CARPET
HALLWAY
HARDWOOD
BEDROOM #1
CARPET
BEDROOM #2
CARPET
W.I.C.
CARPET
ATTIC
BEDROOM #3
CARPET
W.I.C.
CARPET
HALLWAY
HARDWOOD
BEDROOM #1
CARPET
BEDROOM #2
CARPET
W.I.C.
CARPET
15' - 3"2' - 0"15' - 3"14' - 7"4' - 1 1/2"
5' - 0"9' - 0"5' - 0"6' - 0"12' - 0"6' - 0"12' - 0"6' - 0"5' - 0"9' - 0"5' - 0"
80' - 0"43' - 0"2668210683068
DH3050-2W210682668
2668
DH3050-2W
2668
DH3050-2W
2668
2668
DH3050-2W
DH3050-2W DH3050-2W11' - 11"CS30302106821068
21068CS3030INSULATED
SOUND PROOFING
ACCOUSTICAL INSULATION
(BASE SCOPE)
SOUND PROOFING
ACCOUSTICAL INSULATION
(BASE SCOPE)
CONSTRUCTION NOTES:
BLUE SHOWS EXTENT OF
EXTERIOR ENVELOPE FOR
BASE SCOPE
GREEN SHOWS THE ADD-
ALTERNATIVE INSULATION
SCOPE
THE BONUS ROOM ITEMS
SHOULD BE BROKEN OUT
IN SUBCONTRACTOR'S
PROPOSAL
THE DOORS INTO THE BONUS
ROOM AND THE BONUS ROOM
CLOSET DOOR SHOULD BE
INSULATED AS THESE ARE
EXTERIOR ENVELOPE
WHITE WIRE SHELVING IN
ALL CLOSETS
FIBERGLASS TUB/SHOWER COMBO
15' - 3"13' - 6 1/2"5' - 2"15' - 3"2' - 0"15' - 3"14' - 7"43' - 0"11' - 11"24' - 8 1/4"18' - 3 3/4"24' - 8 1/4"18' - 3 3/4"14' - 7"14' - 7"
13' - 6 1/2"5' - 2"15' - 3"3' - 8"3' - 8"3' - 3 1/2"4' - 5 1/2"6' - 11"W.I.C.
CARPET
3' - 8"15' - 3"3' - 8"3' - 8"3' - 3 1/2"4' - 5 1/2"6' - 11"W.I.C.
CARPET
21' - 0"21' - 0"
REQUIREMENTS PER SO. BURLINGTON FIRE MARSHALL
1. ANY FIRE, SMOKE BARRIERS, AND INTERIOR FINISHES
WILL BE MAINTAINED, RECONSTRUCTED OR INSTALLED
PER IBC AND NFPA REQUIREMENTS FOR THE OCCUPANY USE
GROUP (NFPA 1). ALL PENETRATIONS BETWEEN FLOORS,
ATTICS, AND /OR BASEMENTS SHALL BE FIRE STOPPED
WITH FIRE/SMOKE PENETRATION CAULKING/SEALANTS
SHALL BE RED IN COLOR FOR EASE OF IDENTIFICATION.
ALL FIRE WALLS AND SMOKE BARRIERS SHALL BE CLEARLY
STENCILED ABOVE THE CEILING PURSUANT TO IBC AND
NFPA REQUIREMENTS. FOAM FIRE BLOCKING IS PROHIBITED
2. IF THE BASEMENT IS TO BE FINISHED, THE FURNACE AREA
SHALL BE PROTECTED BY SEPARATE FIRE RATED COMPARTMENT
(CEILING INCLUDED), OR BY LIMITED AREA SPRINKLER HEAD
OVER/BY APPLIANCE, INSTALLED BY LICENSED PROFESSIONAL
3. THE BACKSIDE OF BASEMENT STAIRS AND LANDING(S) SHALL
BE PROTECTED BY 5/8" SHEETROCK AND TAPED WITH A MINIMUM
OF ONE COAT.
4. ALL ESCAPE WINDOW SILLS SHALL NOT BE MORE THAN 44"
5. PHOTO SMOKE/CO2 DETECTORS SHALL BE INSTALLED PER
SBFPFSO, AND BE HARD WIRED, INTERCONNECTED TO ALL
DETECTION WITHIN THE DWELLING UNIT
6. SERVICE DOORS FROM DWELLING TO GARAGE SHALL BE
A MINIMUM OF A 45 MINUTE FIRE-RATED DOOR WITH A
SELF-CLOSING/LATCHING DOOR LEAF
7. ALL ELECTRICAL REQUIRES A SEPERATE SUB TRADE WORK
PERMIT/WORK NOTICE ISSUED BY THE SBFD ELECTRICAL
INSPECTOR. ALL ELECTRICAL TRADES PERSONS SHALL HAVE
VALID STATE ELECTRICAL LICENSES
8. ALL PLUMBING WORK REQUIRES A SEPERATE SUB TRADE WORK
PERMIT/WORK NOTICE ISSUED BY DFS-WILLISTON.
ALL PLUMBING TRADES PERSONS SHALL HAVE VALID STATE
PLUMBING LICENSES
9. CONSTRUCTION DUMPSTER(S) SHALL BE LOCATED A MINIMUM
OF 10 FEET FROM ANY COMBUSTIBLE OR OPEN SURFACE OF THE
BUILDING. DUMPSTERS SHALL NOT OBSTRUCT EGRESS
10. NO SMOKING IS ALLOWED WITHIN 10 FEET OF THE BUILDING
11. THE BUILDING SHALL BE IN COMPLIANCE WITH NFPA 241
DURING CONSTRUCTION
12. THE BUILDING SHALL ADDRESS NUMBERS PLACED IN A POSITION
TO BE PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY. THE NUMBERS SHALL BE IN HIGH CONTRAST
WITH THEIR BACKGROUND PER NFPA 1 (2015) AND THE CITY ORDINANCES
13. A 1A-10BC FIRE EXTINGUISHER SHALL BE INSTALLED IN THE KITCHEN
IN PLAIN VIEW.
LINEN CL.
W.I.C.
CARPET
LINEN CL.2' - 0"11' - 6"7' - 0"11' - 9 1/2"2' - 0"11' - 6"7' - 0"11' - 9 1/2"W.I.C.
CARPETPKT2668BATHROOM
TILE5' T/S UNITPKT2668BATHROOM
TILE5' T/S UNITBI50686' - 1"5' - 6 1/2"3' - 7 1/2"3' - 8"5' - 1"4' - 2"6' - 6 1/2"2' - 1"6' - 1"5' - 6 1/2"3' - 7 1/2"5' - 1"4' - 2"6' - 6 1/2"2' - 1"4' - 1 1/2"
9' - 6"9' - 6"42' - 0"9' - 6"9' - 6"
2106821068 266830682668
2106813' - 6"13' - 6"6' - 2"14' - 6 1/2"14' - 6 1/2"6' - 2"
INSULATED
15' - 3"SL5070
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT:
SHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILD 1/4" = 1'-0"9/6/2023 10:56:14 AMA-3
SECOND
FLOOR PLANUnit #109, #11096, 98 Aurora RoadG4
G4
7/18/23
EDGE WD.SOUTH BURLINGTON, VERMONTOPTION
#1B 1/4" = 1'-0"1SECOND FLOOR PLAN