Loading...
HomeMy WebLinkAboutAgenda 08_SD-23-11_1200 1220 Dorset St_1200 Dorset St LLC_PP_FP 180 Market Street, South Burlington, Vermont 05403 | 802-846-4106 | www.southburlingtonvt.gov TO: South Burlington Development Review Board FROM: Marty Gillies, Development Review Planner I SUBJECT: #SD-23-11, 1200 & 1220 Dorset Street, Preliminary & Final Plat Application DATE: September 6, 2023 Development Review Board meeting PROJECT DESCRIPTION Preliminary and final plat application #SD-23-11 of Casey Douglass to amend a previously approved 5.52 acre 6-unit planned unit development. The amendment consists of subdividing lot 6, developed with a single-family home and barn, into two lots of 0.69 acres (Lot 6A) and 0.60 acres (Lot 6B) for the purpose of demolishing the existing single family home and barn and constructing a new single family dwelling on each lot, 1200 Dorset Street CONTEXT The Board began review of this preliminary & final plat application on August 1, 2023, and continued the hearing for the purpose of allowing the applicant time to revise plans and work with City Staff to address the issue identified at that initial meeting. Staff has included in this memorandum only criteria for which the Board provided specific direction to correct at the 8/1/2023 hearing date; criteria that were considered met or the Board agreed to a condition of approval to correct are excluded. COMMENTS Development Review Planner I Marty Gillies and Development Review Planner Marla Keene, hereafter referred to as Staff, have reviewed the plans submitted by the applicant and offer the following comments. Numbered comments for the Board’s attention are in red. The application is subject to zoning district and dimensional standards, subdivision standards, general planned unit development standards, site plan and conditional use review standards, the general regulations of Article 3 and the supplemental regulations of Article 13. SUBDIVISION STANDARDS 15.A.18 Infrastructure, Utilities, and Services B. Potable Water Supply and Wastewater Systems The applicant must demonstrate that adequate potable water supply and wastewater facilities exist to serve the subdivision at buildout, and for each phase of development, in accordance with the following: The project is served by a private wastewater pump station that is approved to remain private. Staff recommends the Board require the applicant to demonstrate adequate capacity in the existing pump station, or a plan to make the necessary upgrades. The Director of Public Works reviewed the plans on 7/19/2023 and offered the following comments: • I’d like to better understand the existing wastewater infrastructure that this project proposes to utilize. Does the engineer have as-built information for the pump station and force main that will accept wastewater from this subdivision? This includes information related to where the force main heads after it leaves the property as it heads north? • There also appears to be a force main located on the east side of the Foulsham Hollow subdivision. I’m not seeing these easements shown on the plat. The applicant had not sufficiently addressed the comments of the Director of Public Works at the time that this report was finalized. Staff will provide a verbal update on this item at the hearing. In the meantime, Staff continues to offer the comment below: 1. Staff recommends the Board direct the applicant to address the comments of the Department of Public Works Director prior to closing the hearing. The Superintendent of the South Burlington Water Department had noted in his initial comments that the FFEs for both newly proposed single-family homes are above the maximum elevation that can be supplied from the Dorset Street water storage tank and meet the minimum water pressure of 35 PSI. However, the applicant testified that the proposed homes will both be served by the Vermont National Country Club water distribution system which utilizes the VNCC water booster pump station to elevate the pressures for those lots located at the highest portions of the VNCC property and will not be directly served by the gravity service from the Dorset Street water storage tank. As such, Staff considers this criterion met as it pertains to purpose of potable water supply. D. Stormwater Facilities The applicant must demonstrate that stormwater management system serving the subdivision has been designed to meet City standards and specifications under Article 13 of these regulations and the South Burlington Ordinance Regulating the use of Public and Private Sanitary Sewerage and Stormwater Systems. The South Burlington Stormwater Superintendent reviewed the plans on 7/1/2023 and offered the following comments: 1. As this is an amendment to an existing planned unit development with more than ½ acre of existing impervious, and the applicant is proposing more than 5,000 square feet (12,595 square feet proposed) of new or redeveloped impervious, the applicant is required to provide stormwater treatment for the entirety of the new and redeveloped impervious on Lots 6A and 6B. This stormwater treatment must meet the standards laid out in the Land Development Regulations Article 13.05 – Stormwater Management. Please provide information on how this site will meet stormwater treatment standards. 2. Staff recommends the DRB include language requiring the applicant to properly maintain EPSC measures for the duration of site work and construction. The applicant had not sufficiently addressed the comments of the Stormwater Superintendent at the time that this report was finalized. Staff will provide a verbal update on this item at the hearing. In the meantime, Staff continues to offer the comment below: 2. Staff recommends the Board direct the applicant to address the comments of South Burlington Stormwater Superintendent prior to closing the hearing. PUD & GENERAL PUD STANDARDS 15.C.07 General PUD I. General PUD Design Standards 5) Civic Spaces and Site Amenities. Civic Spaces and/or Site Amenities must be compatible with the existing or planned development context. General PUDs must comply with applicable Civic Space and/or Site Amenity requirements in Subdivision (Section 15.A.16(C)(4)) and Site Plan (Section 14.06(4)). b. In a General PUD, Civic Spaces required under Subdivision Regulations (Section 15.A.16(C)(4)) and under Site Plan Regulations (Section 14.06(4)) can be satisfied by a combination of Civic Spaces, Site Amenities, or a combination, applied across the PUD area. The proposed amendment to an existing PUD involves the subdivision of one private lot into two private lots to be developed with detached single-family homes and yard space. The applicant has identified private yard space associated with each unit and has demonstrated that both proposed units will each have at least the minimum requirement of 100 square feet of Site Amenity space. As such, Staff now considers this criterion to be met. SITE PLAN & CONDITIONAL USE REVIEW STANDARDS 14.06 General Review Standards A. Relationship of Proposed Structures to the Site. (1) The site shall be planned to accomplish a desirable transition from structure to site, from structure to structure, and to provide for adequate planting, safe pedestrian movement, and adequate parking areas. The DRB shall consider the following: (e) Solar Gain. Orient their rooflines to maximize solar gain potential, to the extent possible within the context of the overall standards of these regulations. The Board on 8/1 indicated a preference to revise the condition recommended by Staff - which required rooflines to have a principal face oriented south to meet this standard - in favor of a broader condition that requires rooflines to maximize solar gain potential regardless of orientation. 3. Staff recommends the Board include a condition of approval requiring rooflines to maximize solar gain potential. B. Relationship of Structures and Site to Adjoining Area 1) The Development Review Board shall encourage the use of a combination of common materials and architectural characteristics (e.g., rhythm, color, texture, form or detailing), landscaping, buffers, screens and visual interruptions to create attractive transitions between buildings of different architectural styles. The provided elevations and landscaping plan demonstrate that the proposed single-family homes will be of relatively similar architectural style to one another and to the adjacent homes on Foulsham Hollow Road. As such, Staff considers no ‘attractive transitions’ need to be provided as per this section, since the proposed and existing buildings are not shown to be of different architectural styles. Staff notes the elevations are merely concepts. Although the proposed elevations may meet the relevant criteria at this stage of review, they are technically non-binding and therefore could be modified in such a way to reduce compliance with the relevant criteria. Based on the direction of the Board, the applicant has committed to including the following characteristics in the proposed single-family homes: • On Lot 6A, the northern proposed lot, the applicant is committing to constructing a two- story single-family home with a dark roof, a ridge line running east-west, a front porch facing south, a recessed garage façade, and a private yard area of at least 100 square feet. • On Lot 6B, the southern proposed lot, the applicant is committing to constructing a two- story single-family home with a dark roof, a front porch facing Foulsham Hollow Road, a rear porch facing Dorset Street, a recessed garage façade facing north, and a private yard area of at least 100 square feet. 4. Staff recommends the Board include a condition requiring the applicant to include the characteristics enumerated above in any Zoning Permit application for the construction of either of the proposed single- family homes. OTHER APPLICABLE STANDARDS 13.17 Residential Design for New Homes C. Standards. 1. Building Orientation. Residential buildings must be oriented to the street, to an approved civic space, or to a courtyard. Primary entries for single family and multi- family buildings must face the street, civic space, or courtyard. Secondary building entries may open onto garages and/or parking areas. Buildings should be oriented to maximize living space and windows to the south, east and west. Residential buildings should orient their rooflines to maximize solar gain potential, to the extent possible within the context of the overall standards of the regulations. The building on Lot 6B is proposed to face the cul-de-sac portion of Foulsham Hollow Road, with a front door and entry porch oriented to that portion of the street, a side- facing garage abutting the driveway & additional parking area, and a rear porch oriented towards Dorset Street. The building on Lot 6A is proposed to face south, generally oriented towards the cul-de-sac portion of Foulsham Hollow Road. The Board indicated at the August 1st hearing that the proposed orientations were acceptable. As such, Staff recommends the Board include in the decision that the above-enumerated aspects of the proposed configuration are a requirement of the approval and considers this criterion met. 2. Building Façades. Building facades are encouraged to employ a theme and variation approach. Buildings should include common elements to appear unified, but façades should be varied from one building to the next to avoid monotony. Front porches, stoops, and balconies that create semi-private space and are oriented to the street are encouraged. Residential buildings with rear facades that orient towards a public recreation path should employ rear porches, balconies, or other features to enhance their architectural detail. The applicant has provided sample elevations for the home proposed to be constructed on Lot 6B that include a rear entrance, a rear porch, and several windows along the west façade that faces Dorset Street and a front porch along the east façade that faces the cul- de-sac portion of Foulsham Hollow Road. The applicant has not provided a sample elevation of the south façade, which faces the straight portion of Foulsham Hollow Road. The north façade of the home proposed to be constructed on Lot 6A includes a rear entrance and a deck and is proposed to be screened via the retention of an existing hedgerow. The west façade of that home has very few architectural details or windows but is proposed to be screened from Dorset Street via the retention of an existing hedgerow. 5. Staff recommends the Board consider whether number of windows or building orientation are important factors in assessing compliance with this criterion. If they are, Staff recommends the Board include a condition requiring the applicant to include the characteristics identified as being critical for compliance with this standard in any Zoning Permit application for the construction of either of the proposed single- family homes. 18.03 Housing Preservation If an existing home is to be removed, Section 18.03 requires a replacement home be constructed & restored to residential use within two years of demolition of the existing home. The applicant has indicated that they intend to complete construction on the proposed single-family home on Lot 6A within two years of demolishing the existing single-family home on the lot. The applicant is aware of the penalties that may apply should the single-family home on Lot 6A not be finished until more than two years after the demolition of the existing single-family home. The standards of this section do not apply to the proposed single-family home of Lot 6B. RECOMMENDATION Staff recommends the Board discuss the project with the applicant and close the hearing, provided that the comments of the Stormwater Superintendent and Director of the Department of Public Works have been adequately addressed by the time of this hearing. Respectfully submitted, Marty Gillies Development Review Planner I PS W WWW WWWETC ETCETCWWEXISTING GRAVEL DRIVEWAY AND CURB CUT TO BE REMOVED ELEC. & (2) TEL. PEDESTAL 20' STORM DRAINAGE EASEMENT TO CITY OF SOUTH BURLINGTON EXISTING PUMP STATION D S S ST D G UDPUMP STATION G MAILBOXES w/ CONC. PAD W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER ELEC. TRANSFORMER (TYP.) G GG G (3) CONDUITS T T 10' SETBACKEXISTING BIKE PATHCLASS II 50' BUFFERDORSET STREETRESTRICTED BUILD AREATO SWIFT STREETTO OLD CROSS ROAD20' SETBACK30' SETBACK 20'S E W E R EA S E M E N T T O H O A 10 ' S E T B A C K 20' SETBACK 35' R . O . W . UT I L I T Y EA S E M E N T TO L O T 4 30' SETBACK 20'SEWEREASEMENTTO LOT 520' UTILITY EASEMENT 10'ELECTRICALEASEMENTTO GMPEXISTING HOUSE EXISTING BARN 20' UTILITY EASEMENT 50' CO N S E R V A T I O N ST R E A M B U F F E R 50' CO N S E R V A T I O N ST R E A M B U F F E R n/f JAM GOLF, LLC GOLF COURSE PARCEL F n/f COMMON LAND HIGHLAND RESIDENTAL PROPERTIES, LP. n/f LOT 173 HIGHLAND RESIDENTIAL PROPERTIES, LP. TO BE REMOVED TO BE REMOVED FOULSHAM HOLLOW ROADMEDALIST DRIVE HIGHLANDS DEVELOPMENT CO LLC n/f I. ISHAM ESTATE n/f J. RUSTAD & D. DISCANO n/f D. ROUILLE n/f S. DAVIS & E. BECHTEL n/f K. EVANS n/f G. BERGERON & R. POTHIER 10' SETBACK 10' SETBACK 20' SETBACK 20' SETBACK 20' SETBACK434434434 433 433 43 3 433 433 433432 432432 432 432 43 2 432 432 4324314314 3 1 431431 4314314314 3 1 431 430 430 430430430 43 0 430 43043043042942 9 429 42 9 429429429429429429 429429429 428 42 8 428428428 428428428428428 428 428427 427 427427427 427 427 427 427427427 427 426 426426 426 426426426 426 42642 5 4 2 5 425 425425 425424424424424424 42342342342 3 423 423422422 422422422422422 421421 421421421421421421421420420420420420420420420420419419419 41941941941941941841841 8 418 418418418 418 418417417417417417417 417416416 4164164164164164164154154154154154154154154144144 1 4 414 414414414 4144134134 1 3 41341 3 413413 413412412412412 412412412412412 411411411 4 1 1411411411411410410 410410410 410 410409409409409 409 409 4094094084 0 8 408408408 4084084074074 0 7 407407 407407 406 406406 4 0 6406406 405 405405405 405 405405404 404404 4044 0 4 404 4 0 3 40 3 4034034034 0 2 40 2 4024024014 0 1 4014004 0 0400399399398 10" OAK MAILBOX MAILBOXM A I L B O X MAILBOX C.O. C.O. SID E W A L K SIDEW AL K SIDEWALK SIDEWALK60' R.O.W.LOT 1 0.44 AC. R.O.W. 0.86 AC. LOT 2 0.80 AC. LOT 3 0.77 AC. LOT 4 0.81 AC. LOT 5 0.33 AC.250' FROM ℄ OF DORSET STREET R.O.W.LOT 6 1.29 AC. 207'±340'±67'±109'±64'±111'±4'±129'±20' SETBACK424422EXISTING TREES TO BE REMOVED (TYP.) REMOVE UNDERBRUSH AND SECONDARY GROWTH EXISTING RECESSED CURB REMOVE SHRUBS EXISTING TREES TO BE REMOVED (TYP.) (2) 12" CEDAR 8" ELM (5) 8" BLUE SPRUCE 8" BALSAM FIR 10" BALSAM FIR 10" BALSAM FIR 6" RED MAPLE 6" SILVER MAPLE 8" BLUE SPRUCE (5) 10" NORWAY SPRUCE 8" NORWAY MAPLE 18" NORTHERN RED OAK 24" BLACK LOCUST 10" BLUE SPRUCEJAPANESE YEW10" CHESTNUT OAK 10" BLACK OAK 12" WHITE SPRUCE 3-BOL 8" WHITE CEDAR 14" AMERICAN ELM 4" NORWAY SPRUCE 12" SILVER MAPLE (19) 6"-8" NORTHERN WHITE CEDAR 8" NORWAY MAPLE 8" BOX ELDER 16" NORWAY MAPLE JAPANESE YEWHEDGEROW(10'-15' HEIGHT) COMMON LILAC COMMON LILAC JAPANESE YEW 8" YELLOW BUCKEYE 8" BLACK MAPLE 6" SILVER MAPLE 18" SHAGBARK HICKORY DSM DSM MAB 1" = 30' 22117 C1.0 01/05/2023 LOCATION MAP 1" = 2000' 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 EXISTING CONDITIONS and PROPOSED DEMOLITIONS SITE PLAN PROJECT LOCATION A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 NOTES 1.UTILITIES SHOWN DO NOT PURPORT TO CONSTITUTE OR REPRESENT ALL UTILITIES LOCATED UPON OR ADJACENT TO THE SURVEYED PREMISES. EXISTING UTILITY LOCATIONS ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL FIELD VERIFY ALL UTILITY CONFLICTS. ALL DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER. THE CONTRACTOR SHALL CONTACT DIG SAFE (888-344-7233) PRIOR TO ANY CONSTRUCTION. 2.PROPERTY LINE INFORMATION IS BASED ON A PLAN ENTITLED "PAUL F. HEALD 6 LOT SUBDIVISION DORSET STREET" PREPARED BY CIVIL ENGINEERING ASSOCIATES, INC. DATED AUGUST 2001, LAST REVISED 12-4-01. THIS PLAN IS NOT A BOUNDARY SURVEY AND IS NOT INTENDED TO BE USED AS ONE. 3.PROPERTY LINE BEARINGS ARE BASED ON MAGNETIC NORTH NOT TRUE NORTH. 4.CONTOUR INFORMATION IS BASED UPON LIDAR DATA FROM 2014. HORIZONTAL AND VERTICAL DATUM BASED ON VCS NAD 83 AND NAVD 88. LEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COMETC 2 LOT SUBDIVISION LOT 6 EXISTING DECIDUOUS TREE EXISTING CONIFEROUS TREE P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 5/5/2023 8:32:54 AMMAN MADE STEEP SLOPES S W WWW W W WWWWGGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETCETCETCWW W W W W WWG G G G GG G G GGGSSSS SSSSFM FM FMFMFMFMFM FM FMFMFMFMFMFMFMSSSSSSSSSSSSSSSSSSSSWWPROPOSED 14' WIDE PAVED SHARED DRIVEWAY OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEELEC. & (2) TEL. PEDESTAL 20' STORM DRAINAGE EASEMENT TO CITY OF SOUTH BURLINGTON WWWWWWWWWWWWWWS SFMFMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM STST ST ST D ET C ETC G G G G UDEX. SMH G G MAILBOXES w/ CONC. PAD W W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER G G GG(3) CONDUITS ETCG EXISTING MAN MADE SLOPE. TIE PROPOSED CONTOURS TO AND THROUGH THIS SLOPE, AS SHOWN EXTEND SIDEWALK TO PROPOSED DRIVE STONE WALL, STEPPED 2' X 4' BOULDERS (MAX 8' HIGH) S PROPOSED PROPERTY LINE T EXISTING BIKE PATHDORSET STREETTO SWIFT STREET20 'SE W E R EA S E M E N T T O H O A 35' R . O . W . UT I L I T Y EA S E M E N T T O L O T 4 20' UTILITY EASEMENT 10'ELECTRICALEASEMENTTO GMP20' UTILITY EASEMENT C.O. PROPOSED HOUSE FFE=436.0±FOULSHAM HOLLOW ROAD4" WATER MAIN20" WATER MAINEX. 4 " SEWER S ERV ICE EX. 2" WATER SERVICE6" PE433.5 + 4 3 0 4 2 8 4 2 6 430 428 426 424 4 2 2 42 0420 42 0422424426 42241 8 4164144 1 6 416 418 42 0 422424418418 434434434 433 433 43 3 433 433 433432 432 432 432 43 2 432 43 2431431 43 1 431431 4314 3 1 430430 430 43043043042 9 429429429428 428428428427427 427 42742642442342242142142142142042042041941941841 8 418 4184174174164164164154154154154144 1 4 414413 4 1 3 413412 412412412 411411411410410410409 409409409 4 0 8 40840840740740740 6406406 MAILBOX MAILBOXM A I L B O X MAILBOX SID E W A L K SIDE W AL K SIDEWALK SIDEWALK60' R.O.W.FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC 434 433432430428426431 432 433 434 428431422424426 428 430 432 GARAGE FFE=434.0± PROPOSED GARAGE FFE=434.0± + 433.5 433.5 + 431 432433 434 434 COVEREDPORCHSCREEN PORCH POTENTIAL PATIO 4 2 6 426427COVERED PORCH POTENTIAL COVERED PORCH EXISTING RECESSED CURB 433.5 + SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT PROPOSED 12' WIDE PAVED DRIVEWAY BUILDING TO BE CONSTRUCTED WITH NFPA13D SPRINKLER SYSTEM ABANDONED FM1" = 20'C2.0 PROPOSED CONDITIONS PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' 49' PROJECT LOCATIONLEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS 01/05/2023 2 LOT SUBDIVISION LOT 6 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 LOT SIZE CATEGORY EXISTING SETBACK FRONT YARD - FOULSHAM HOLLOW FRONT YARD - DORSET STREET 20' ZONING REGULATIONS 20' 23' 20' 9,500 S.F. (MIN.) COVERAGE BUILDING COVERAGE 20%6% BUILDING HEIGHT 28' (PITCHED) SIDE YARD 10'117' 56,167 S.F. ± ZONING DISTRICT:SEQ-NEIGHBORHOOD RESIDENTIAL LOT COVERAGE 40%10% 65' 62' 13% 24' 21% 29,947 S.F. ± PROPOSED LOT 6A 21' 9% 72' 24% 26,219 S.F. ± PROPOSED LOT 6B 28' 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF 08/07/23 DSM REVISIONS PER CITY COMMENTS P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 8/8/2023 11:26:31 AM, DWG To PDF.pc3 S W WWW W W WWWWGGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETCETCETCWW W W W W WWG G G G GG G G GGGSSSS SSSSFM FM FMFMFMFMFM FM FMFMFMFMFMFMFMSSSSSSSSSSSSSSSSSSSSWWPROPOSED 14' WIDE PAVED SHARED DRIVEWAY OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEELEC. & (2) TEL. PEDESTAL 20' STORM DRAINAGE EASEMENT TO CITY OF SOUTH BURLINGTON WWWWWWWWWWWWWWS SFMFMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM STST ST ST D ET C ETC G G G G UDEX. SMH G G MAILBOXES w/ CONC. PAD W W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER G G GG(3) CONDUITS ETCG EXISTING MAN MADE SLOPE. TIE PROPOSED CONTOURS TO AND THROUGH THIS SLOPE, AS SHOWN EXTEND SIDEWALK TO PROPOSED DRIVE STONE WALL, STEPPED 2' X 4' BOULDERS (MAX 8' HIGH) S PROPOSED PROPERTY LINE T EXISTING BIKE PATHDORSET STREETTO SWIFT STREET20 'SE W E R EA S E M E N T T O H O A 35' R . O . W . UT I L I T Y EA S E M E N T T O L O T 4 20' UTILITY EASEMENT 10'ELECTRICALEASEMENTTO GMP20' UTILITY EASEMENT C.O. PROPOSED HOUSE FFE=436.0±FOULSHAM HOLLOW ROAD4" WATER MAIN20" WATER MAINEX. 4 " SEWER S ERV ICE EX. 2" WATER SERVICE6" PE433.5 + 4 3 0 4 2 8 4 2 6 430 428 426 424 4 2 2 42 0420 42 0422424426 42241 8 4164144 1 6 416 418 42 0 422424418418 434434434 433 433 43 3 433 433 433432 432 432 432 43 2 432 43 2431431 43 1 431431 4314 3 1 430430 430 43043043042 9 429429429428 428428428427427 427 42742642442342242142142142142042042041941941841 8 418 4184174174164164164154154154154144 1 4 414413 4 1 3 413412 412412412 411411411410410410409 409409409 4 0 8 40840840740740740 6406406 MAILBOX MAILBOXM A I L B O X MAILBOX SID E W A L K SIDE W AL K SIDEWALK SIDEWALK60' R.O.W.FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC 434 433432430428426431 432 433 434 428431422424426 428 430 432 GARAGE FFE=434.0± PROPOSED GARAGE FFE=434.0± + 433.5 433.5 + 431 432433 434 434 COVEREDPORCHSCREEN PORCH POTENTIAL PATIO 4 2 6 426427COVERED PORCH POTENTIAL COVERED PORCH EXISTING RECESSED CURB 433.5 + SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT PROPOSED 12' WIDE PAVED DRIVEWAY BUILDING TO BE CONSTRUCTED WITH NFPA13D SPRINKLER SYSTEM ABANDONED FM1" = 20'C2.0 PROPOSED CONDITIONS PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATIONLEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS 01/05/2023 2 LOT SUBDIVISION LOT 6 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 LOT SIZE CATEGORY EXISTING SETBACK FRONT YARD - FOULSHAM HOLLOW FRONT YARD - DORSET STREET 20' ZONING REGULATIONS 20' 23' 20' 9,500 S.F. (MIN.) COVERAGE BUILDING COVERAGE 20%6% BUILDING HEIGHT 28' (PITCHED) SIDE YARD 10'117' 56,167 S.F. ± ZONING DISTRICT:SEQ-NEIGHBORHOOD RESIDENTIAL LOT COVERAGE 40%10% 65' 62' 13% 24' 21% 29,947 S.F. ± PROPOSED LOT 6A 49' 21' 9% 72' 24% 26,219 S.F. ± PROPOSED LOT 6B 28' 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF 08/07/23 DSM REVISIONS PER CITY COMMENTS SITE AMENITY REQUIREMENT : 100 S.F. (MIN.) YARD PER LOT P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 8/8/2023 11:26:39 AM, DWG To PDF.pc3 S W GGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETCETCETCWG G G G GG G G GGGS SSSSFM FM FMFMFMFMFM FM FMFMFMFMFMFMFMSSSSSSSSSSSSSSSSSSSSWWOE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOES SFMFMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM STST ST ST D ET C ETC G G PERMANENT STABILIZATION- INSTALL 4" TOPSOIL, FERTILIZE, LAWN SEED AND INSTALL ROLLED EROSION CONTROL MATTING (TYP.) G G UDEX. SMH G G MAILBOXES w/ CONC. PAD W W W G G GG ETCG TEMPORARY STABILIZATION- INSTALL EROSION CONTROL MATTING TEMPORARY STABILIZED CONSTRUCTION ENTRANCE PERMANENT STABILIZATION- SURFACE WALKWAY (TYP.) PERMANENT STABILIZATION- PAVED DRIVEWAY (TYP.) INSTALL SILT FENCING (TYP.) DOWN GRADIENT OF ALL DISTURBED AREAS INSTALL CONSTRUCTION LIMITS TAPE (TYP.) DSTST ST ST ST EX. CB RIM=415.2± INV.=409.8± T EXISTING BIKE PATHDORSET STREETTO SWIFT STREETC.O. PROPOSED HOUSE FFE=436.0±FOULS HA M H OLL O W R OA D6" PETEMPORARY TOPSOIL STOCKPILE 4 3 0 4 2 8 4 2 6 430 428 426 424 4 2 2 42 0420 42 0422424426 42241 8 4164144 1 6 416 418 42 0 422424418418 434434434 433 433 43 3 433 433 433432 432 432 432 43 2 432 43 2431431 43 1 431431 4314 3 1 430430 430 43043043042 9 429429429428 428428428427427 427 42742642442342242142142142142042042041941941841 8 418 4184174174164164164154154154154144 1 4 414413 4 1 3 413412 412412 412 411411411410410410409 409409409 4 0 8 40840840740740740 6406406 MAILBOX MAILBOXM A I L B O X MAILBOX C.O. SID E W A L K SIDE W AL K SIDEWALK SIDEWALK FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± BASEMENT=426.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC434 433432430428426431 432 433 428422424426 428 430 432 GARAGE FFE=434.0± PROPOSED GARAGE FFE=435.5± 434 COVEREDPORCHSCREEN PORCH POTENTIAL PATIO 426427COVERED PORCH POTENTIAL COVERED PORCH TEMPORARY TOPSOIL STOCKPILE BUILDING TO BE CONSTRUCTED WITH NFPA13D SPRINKLER SYSTEM 425424424423421423 422 433 434 431 432433 425433 432 431 4224 2 6 TEMPORARY STABILIZATION- PLACE EROSION CONTROL MATTING IN GRASSED DRAINAGE SWALE INSTALL TREE PROTECTION FM1" = 20'C3.0 EPSC SITE PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATION LEGEND NOTES: 1.ALL EROSION AND SEDIMENT CONTROL DEVICES MUST BE INSTALLED AND STABILIZED BEFORE THE START OF CONSTRUCTION. 2.LOAM, SEED AND MULCH ALL DISTURBED AREAS (TYP.) 3.INSTALL TEMPORARY STABILIZATION OF DISTURBED SOILS THROUGH THE INSTALLATION OF 1" OF HAY MULCH NO MORE THAN 7 DAYS AFTER WORK HAS CEASED IN A PARTICULAR AREA. 4.SLOPES >3:1 SHALL RECEIVE EROSION CONTROL MATTING. 5.MAXIMUM AMOUNT OF DISTURBED SOILS TO BE LIMITED TO NO MORE THAN 2 ACRES. 6.SILT FENCE CONTRIBUTORY AREA TO BE LIMITED TO 14 ACRE / 100 L.F. 7.SOIL INFORMATION PROVIDED BY NATURAL RESOURCES CONSERVATION SERVICES WEB SOIL SURVEY 09/13/2021 CONSTRUCTION LIMITS TAPE EROSION CONTROL MATTING SILT FENCE TREE PROTECTION INLET PROTECTION 01/05/2023 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 2 LOT SUBDIVISION LOT 6 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 08/07/23 DSM REVISIONS PER CITY COMMENTS N.T.S. TREE PROTECTION - FENCING REVISED 2/12/2015L-006L-006 Tree ProtectionEXISTING GRADE DRIP LINE FENCE NOTES: 1.THIS FENCE SHALL BE LOCATED OUTSIDE THE DRIP LINE OF THE TREE TO BE SAVED AND IN NO CASE CLOSER THAN 5' TO THE TRUNK OF ANY TREE. 2.FENCE POST SHALL BE STANDARD STEEL POSTS OR WOOD POSTS WITH A MINIMUM CROSS SECTIONAL AREA OF 3.0 SQ. IN. 3.THE FENCE MAY BE EITHER 40" HIGH SNOW FENCE, 40" PLASTIC WEB FENCING OR ANY OTHER MATERIAL AS APPROVED BY THE ENGINEER.. 08/29/23 DSM REVISIONS PER CITY COMMENTS P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 8/29/2023 2:24:41 PM, DWG To PDF.pc3 PS S S D DORSET STREETFOULSHAM HOLLOW ROAD6" PE8" MAPLE 4" MAPLE 8" OAK 8" OAK 8" OAK8" O A K 10" MAPLE 12" MAPLE 12" SPRUCE 12" MAPLE 12" OAK 4" MAPLE 4" MAPLE 10" OAK8" ELM 8" BALSAM FIR 10" BALSAM FIR 10" BALSAM FIR 6" RED MAPLE 6" SILVER MAPLE 8" BLUE SPRUCE (5) 10" NORWAY SPRUCE 8" NORWAY MAPLE 10" BLUE SPRUCE 10" CHESTNUT OAK 10" BLACK OAK 12" SILVER MAPLE (19) 6"-8" NORTHERN WHITE CEDAR 8" NORWAY MAPLE 8" BOX ELDER 16" NORWAY MAPLE JAPANESE YEWHEDGEROW(10'-15' HEIGHT) COMMON LILAC COMMON LILAC JAPANESE YEW 8" YELLOW BUCKEYE 8" BLACK MAPLE 6" SILVER MAPLE 18" SHAGBARK HICKORY 1" = 20'C1.1 PROPOSED LANDSCAPE PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATIONLEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS 01/05/2023 2 LOT SUBDIVISION LOT 6 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 5/5/2023 8:32:36 AM S W WWW W W WWWWGGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETCETCETCWW W W W W WWG G G G GG G G GGGSSSS SSSSFM FM FM FMFMFMFM FM FMFMFMFMFMFMFMSSSSSSSSSSSSSSSSSSSSWWOE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOENEW UTILITY POLE AND SERVICE DROP ELEC. & (2) TEL. PEDESTAL 20' STORM DRAINAGE EASEMENT TO CITY OF SOUTH BURLINGTON WWWWWWWWWWWWWW10' MIN. S SFMFMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM STST ST ST D ET C ETC G G INV=426.0 G G UDEX. SMH G G MAILBOXES w/ CONC. PAD W W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER G G GG G (3) CONDUITS ETCUNDERGROUND POWER AND COMMUNICATION (TYP) G NEW GAS SERVICE NEW GAS SERVICE CUT AND REROUTE EXISTING WATER SERVICE EXTEND SIDEWALK TO PROPOSED DRIVE CUT AND REROUTE EXISTING 2" TYPE K WATER SERVICE WITH A NEW 1" TYPE K WATER SERVICE TO THE NEW HOUSE S INV=426.0 MAINTAIN 18" MIN. VERTICAL SEPARATION BETWEEN WATER AND SEWER SERVICES INV=419.0± (ASSUMED) PROPOSED PROPERTY LINE T EXISTING BIKE PATHDORSET STREETTO SWIFT STREET20 'SE W E R EA S E M E N T T O H O A 35' R . O . W . UT I L I T Y EA S E M E N T T O L O T 4 20' UTILITY EASEMENT 10'ELECTRICALEASEMENTTO GMP20' UTILITY EASEMENT C.O. PROPOSED HOUSE FFE=436.0±FOULSHAM HOLLOW ROAD4" WATER MAIN20" WATER MAINEX. 4 " SEWER S ERV ICE EX. 2" WATER SERVICE2" TYPE KWATER SERVICE4" SDR 35 PVCSEWER SERVICEc.o.6" PEMAILBOX MAILBOXM A I L B O X MAILBOX SID E W A L K SIDE W AL K SIDEWALK SIDEWALK60' R.O.W.FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC GARAGE FFE=434.0± PROPOSED GARAGE FFE=434.0± 4" SDR 35 PVC SEWER SERVICE c.o.COVEREDPORCHSCREEN PORCH POTENTIAL PATIO COVERED PORCH POTENTIAL COVERED PORCH EXISTING RECESSED CURB REROUTE AND EXTEND THE EXISTING 4" SDR35 PVC SEWER SERVICE MAINTAIN MIN. SLOPE OF 14" PER FOOT 1" TYPE K WATER SERVICE SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT BUILDING TO BE CONSTRUCTED WITH NFPA13R SPRINKLER SYSTEM ABANDONED FM1" = 20'C2.1 PROPOSED UTILITY SITE PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATION 01/05/2023 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 2 LOT SUBDIVISION LOT 6 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 LEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF 08/07/23 DSM REVISIONS PER CITY COMMENTS P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 8/8/2023 11:16:31 AM, DWG To PDF.pc3 S W WW W W W WWWWGGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETC ETCETCWW W W W W WWG G G G GG G G GGGSSSS S SSFM FM FMFMSSSSSSWWOE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEWWWWWWWWWWWWWFM FM FMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM ST ST ET C ETC G G GGUDEX. SMH G G MAILBOXES w/ W W W G GG(3) CONDUITS ETCG EXISTING RECESSED CURB DSTST ST ST ST EX. CB RIM=415.2± INV.=409.8± CONTRACTOR TO RESTORE ALL DISTURBED AREAS BY INSTALLING 4” TOPSOIL, SEED, AND EROSION CONTROL MATTING (TYP.) ROOF PITCH T EXISTING BIKE PATHDORSET STREETTO SWIFT STREETC.O.FOULS HA M H OLL O W R OA D4" WATER MAIN20" WATER MAINEX . 4 " S EW ER SER V IC E EX. 2" WATER SERVICE6" PE4 3 0 4 2 8 4 2 6 430 428 426 424 4 2 2 42 0420 42 0422424426 42241 8 4164144 1 6 416 418 42 0 422424418418 4344 3 4 434434434434 433 433 43 3 433 433 433433 433432432432 432 432 4 3 2 432 43 2432 4324 3 1 43143143 1 431431 4314 3 1 43 1 430 430 43 0 430430 430 430430429 42 9 429429429429 428 4 2 8 428428428427 427427 427427426 42642 5 424424 42342 3 42242142142142142042042041941941841 8 418 418417417416416416415415415415414414 414413 4 1 3 413412 MAILBOX MAILBOXM A I L B O X MAILBOX SID E W A L K SIDE WA LK SIDEWALK SIDEWALK 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC434 433432430428426431 432 433 428422424426 428 430 432 434 426427ABANDONED FM425424424423421423 422 433 434 431 432433 425433 432 431 4224 2 6 ROOF PITCH 300± S.F. TO BE SITE BALANCED 30± S.F. TO BE SITE BALANCED 265± S.F. TO BE SITE BALANCED 600± S.F. SITE BALANCE POI PROPOSED OUTLET STRUCTURE SEE OUTLET STRUCTURE DETAIL PROPOSED FOREBAY SEE DETAIL SHEET 4.1 PROPOSED GRAVEL WETLAND. SEE DETAIL SHEET 4.1 TO S/ N 00 1 FM1" = 20'SW2 PROPOSED STORMWATER SITE PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATION 08/28/2023 2 LOT SUBDIVISION LOT 6 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 · · · · · · “” · · § § § § § § § § § · · § § § § § § · · · SOIL DATA IS APPROXIMATE AND BASED ON INFORMATION ABSTRACTED FROM THE NATURAL RESOURCES CONSERVATION SERVICE WEB SOIL SURVEY, VERSION 21, DATED SEPTEMBER 17, 2018 PROPOSED IMPERVIOUS SUBCATCHMENT AREA LEGEND AREA TO BE SITE BALANCED = 600± S.F.P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 8/29/2023 2:25:12 PM, DWG To PDF.pc3 S ETC ETCETCETCOE S S FMFMFMFMFMFMFMFMFMFMFMFMFMFMFM ST D G EX. SMH MAILBOXES w/ CONC. PAD (3) CONDUITS T EXISTING BIKE PATHDORSET STREETTO SWIFT STREETPROPOSED HOUSE FFE=436.0±FOULSHAM HOLLOW ROADEX. 4 " SEWER S ERV ICE 6" PE433.5 + MAILBOX MAILBOXM A I L B O X MAILBOX SID E W A L K SIDE W AL K SIDEWALK SIDEWALK FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC GARAGE FFE=434.0± PROPOSED GARAGE FFE=434.0± + 433.5 433.5 +COVEREDPORCHSCREEN PORCH POTENTIAL PATIO COVERED PORCH POTENTIAL COVERED PORCH 433.5 + BUILDING TO BE CONSTRUCTED WITH NFPA13D SPRINKLER SYSTEM ABANDONED FM1" = 20'FP-1 FIRE TRUCK AUTO TURN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATIONLEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS 08/07/2023 2 LOT SUBDIVISION LOT 6 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 8/8/2023 11:27:24 AM, DWG To PDF.pc3