HomeMy WebLinkAboutPermit Certificate of Occupancy CO-23-02COMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Title: 2020 Vermont Commercial Building Energy Standards Project Type:Addition Vertical Glazing / Wall Area:38% Location:Burlington, Vermont Climate Zone:6a Construction Site: 1795 Shelburne Road South Burlington, Vermont 05819 Owner/Agent:Designer/Contractor: Project Information Energy Code: Mazda South Burlington Building Area Floor Area 1-addition (Automotive Facility) : Nonresidential 2220 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - addition]2113 ---40.0 0.025 0.025 Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - addition]5574 ---30.0 0.032 0.025 Floor: Unheated Slab-On-Grade, Vertical 3 ft., [Bldg. Use 1 - addition] (c) 175 ---10.0 0.510 0.480 NORTH Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]2162 13.0 15.0 0.043 0.044 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Kawneer 451 UT, SHGC 0.35, [Bldg. Use 1 - addition] (b) 930 ------0.330 0.290 Door: Glass (over 50% glazing): Metal Frame, Entrance Door, Perf. Specs.: Product ID Kawneer 350, SHGC 0.24, [Bldg. Use 1 - addition] (b) 113 ------0.670 0.680 EAST Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]646 13.0 15.0 0.043 0.044 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Kawneer 451 UT, SHGC 0.35, [Bldg. Use 1 - addition] (b) 415 ------0.330 0.290 Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]1507 13.0 15.0 0.043 0.044 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Kawneer 451 UT, SHGC 0.35, [Bldg. Use 1 - addition] (b) 485 ------0.330 0.290 Door: Glass (over 50% glazing): Metal Frame, Entrance Door, Perf. Specs.: Product ID Kawneer 350, SHGC 0.24, [Bldg. Use 1 - addition] (b) 42 ------0.670 0.680 SOUTH Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]1307 13.0 15.0 0.043 0.044 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Kawneer 451 UT, SHGC 0.35, [Bldg. Use 1 - addition] (b) 245 ------0.330 0.290 Door: Glass (over 50% glazing): Metal Frame, Entrance Door, Perf. Specs.: Product ID Kawneer 350, SHGC 0.24, [Bldg. Use 1 21 ------0.670 0.680 Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 91 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter - addition] (b) WEST Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]533 13.0 15.0 0.043 0.044 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Kawneer 451UT, SHGC 0.35, [Bldg. Use 1 - addition] (b) 60 ------0.330 0.290 Door: Glass (over 50% glazing): Metal Frame, Entrance Door, Perf. Specs.: Product ID Kawneer 350, SHGC 0.24, [Bldg. Use 1 - addition] (b) 48 ------0.670 0.680 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Project Notes Building consists of an addition, as well as envelope improvements to the existing showroom. All new envelope components meet the prescriptive code requirements of Table 402.1 for the individual components. Envelope FAILS: Design 10% worse than code Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 92 ofPage Inspection Checklist Requirements: 28.0% were addressed directly in the COMcheck software COMcheck Software Version COMcheckWeb Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2020 Vermont Commercial Building Energy Standards Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable C402.3.1 [PR10]1 The vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable C402.3.1 [PR11]1 The skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 93 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable C104 [FO3]2 Installed slab-on-grade insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Location on plans/spec: n/a See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 94 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable C402.4.1. 5, C402.4.1. 7 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable C402.3.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.3.3, C402.3.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.1. 7 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.5 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Vestibule space heat tempering limited to 55°F and thermostatically (programmable only) controlled as separate zone. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 95 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.4.3, C403.7.7 [ME58]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 96 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.6 [EL26]2 Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Location on plans/spec: n/a C405.7 [EL27]2 Electric motors meet the minimum efficiency requirements of Tables C405.7(1) through C405.7(4). Efficiency verified through certification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: Products were reviewed during submittal phase of construction C405.8.2, C405.8.2. 1 [EL28]2 Escalators and moving walks comply with ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.9 [EL29]2 Total voltage drop across the combination of feeders and branch circuits <= 5%. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E001, Electrical Notes Part 3, C2 C405.10 [EL30]2 New parking lots with occupancy groups in Table 405.11 shall provide electric vehicle parking spaces including cabinet, box or enclosure to a conduit linking parking space with electrical service. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: E101 Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 97 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1.1 [IN3]1 Roof insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable C402.2.1 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable C104 [IN6]1 Installed above-grade wall insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C104 [IN8]2 Installed floor insulation type and R- value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable C402.4.1. 3 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable C104 [IN2]1 Installed roof insulation type and R- value consistent with insulation specifications reported in plans and COMcheck reports. For some ceiling systems, verification may need to occur during Framing Inspection. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 98 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C402.4.1. 7 [FI37]1 Weatherseals installed on all loading dock cargo doors. Complies Does Not Not Observable Not Applicable C408.1.1 [FI63]1 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Mazda South Burlington 01/13/23Report date: 99 ofPage COMcheck Software Version 4.1.5.3 Interior Lighting Compliance Certificate Project Title: 2020 Vermont Commercial Building Energy Standards Project Type:New Construction Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: Autosaver Mazda Credits: 6.0 Required 7.0 Proposed High Efficiency HVAC - C406.2, 3.0 credit Reduced Lighting Power - C406.3.1, 4.0 credit Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Car Sales (Common Space Types:Sales Area)10000 0.89 8880 8900Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Car Sales (Common Space Types:Sales Area) A: Other:1 8 72 576 A2: Other:1 2 74 148 C: Other:1 9 20 180 D: Other:1 48 44 2112 F: Other:1 39 30 1170 G: Other:1 2 10 20 H: Other:1 4 49 196 J: Other:1 78 42 3276 L: Other:1 2 24 48 M: Other:1 6 22 132 P: Other:1 2 30 60 7918Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2020 Vermont Commercial Building Energy Standards requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 11% better than code Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 121 ofPage COMcheck Software Version 4.1.5.3 Mechanical Compliance Certificate Project Title: 2020 Vermont Commercial Building Energy Standards Project Type:New Construction Location:South Burlington, Vermont Climate Zone:6a Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: Autosaver Mazda Credits: 6.0 Required 7.0 Proposed High Efficiency HVAC - C406.2, 3.0 credit Reduced Lighting Power - C406.3.1, 4.0 credit Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Cooling: 1 each - Single Package Vertical AC Unit, Capacity = 60 kBtu/h, Air-Cooled Condenser, Unknown Economizer Proposed Efficiency = 12.00 EER, Required Efficiency: 10.35 EER Fan System: None 3 HVAC System 1 (Single Zone): Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2020 Vermont Commercial Building Energy Standards requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 122 ofPage Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.5.3 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2020 Vermont Commercial Building Energy Standards Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 123 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C403.2.4. 5, C403.2.4. 6 [FO9]3 Snow/ice melting system sensors for future connection to controls. Freeze protection systems have automatic controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 124 ofPage Section # & Req.ID Plumbing Rough-In Inspection Complies?Comments/Assumptions C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable C404.7 [PL8]3 Demand recirculation water systems have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 125 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.2.6 [ME41]3 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Complies Does Not Not Observable Not Applicable C403.2.3 [ME118]1 Building heating with electrical resistance units, including baseboard radiation, heat pump reheat coils, duct coils, boilers, domestic hot water heaters, outdoor air intake grids, and coils in terminal units and air systems, prohibited. Complies Does Not Not Observable Not Applicable C403.8.1 [ME65]3 HVAC fan systems at design conditions do not exceed allowable fan system motor nameplate hp or fan system bhp. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.8.3 [ME117]2 Fans have efficiency grade (FEG) >= 67. The total efficiency of the fan at the design point of operation <= 15% of maximum total efficiency of the fan. Complies Does Not Not Observable Not Applicable C403.2.13 [ME71]2 Unenclosed spaces that are heated use only radiant heat. Electric resistance heating is prohibited for heating spaces outside a building. Complies Does Not Not Observable Not Applicable C403.2.3 [ME55]2 HVAC equipment efficiency verified.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.2.6. 1 [ME59]1 Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable C403.7.2 [ME115]3 Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans as stipulated in the Vermont Fire and Building Safety Code. Complies Does Not Not Observable Not Applicable C403.7.5 [ME116]3 Kitchen exhaust systems comply with replacement air and conditioned supply air limitations, and satisfy hood rating requirements and maximum exhaust rate criteria. Complies Does Not Not Observable Not Applicable C403.2.9 [ME60]2 HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. Ducts, air handlers and filter boxes shall be sealed. Joints and seams shall comply with Section 603.9 of the International Mechanical Code. Complies Does Not Not Observable Not Applicable C403.2.9 [ME10]2 Ducts and plenums sealed based on static pressure and location. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 126 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.2.9. 1.3 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable C403.6.6 [ME110]3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 127 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.2. 2 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable C405.2.1 [EL18]1 Occupancy sensors installed in classrooms/lecture/training rooms, conference/meeting/multipurpose rooms, copy/print rooms, lounges/breakrooms, enclosed offices, open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. Complies Does Not Not Observable Not Applicable C405.2.1, C405.2.1. 1, C405.2.1. 3 [EL23]2 Occupancy sensors installed in classrooms/lecture/training rooms, conference/meeting/multipurpose rooms, copy/print rooms, lounges/breakrooms, enclosed offices, open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 for open plan office spaces. Complies Does Not Not Observable Not Applicable C405.2.2, C405.2.2. 1, C405.2.2. 2 [EL22]2 Each area not served by occupancy sensors (per C405.2.1) have time- switch controls and functions detailed in sections C405.2.2.1 and C405.2.2.2. Complies Does Not Not Observable Not Applicable C405.2.3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL20]1 Daylight zones provided with individual controls that control the lights independent of general area lighting. See code section C405.2.3 Daylight-responsive controls for applicable spaces, C405.2.3.1 Daylight responsive control function and section C405.2.3.2 Sidelit zone. Complies Does Not Not Observable Not Applicable C405.2.4 [EL4]1 Separate lighting control devices for specific uses including display/accent lighting, task lighting, nonvisual purposes, and hotel/motel lighting occpancy override switching. Complies Does Not Not Observable Not Applicable C405.2.4 [EL8]1 Additional interior lighting power allowed for special functions automatically controlled and separated from general lighting with dedicated and independent controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 128 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.6 [EL26]2 Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. Complies Does Not Not Observable Not Applicable C405.7 [EL27]2 Electric motors meet the minimum efficiency requirements of Tables C405.7(1) through C405.7(4). Efficiency verified through certification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). Complies Does Not Not Observable Not Applicable C405.8.2, C405.8.2. 1 [EL28]2 Escalators and moving walks comply with ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Complies Does Not Not Observable Not Applicable C405.9 [EL29]2 Total voltage drop across the combination of feeders and branch circuits <= 5%. Complies Does Not Not Observable Not Applicable C405.10 [EL30]2 New parking lots with occupancy groups in Table 405.11 shall provide electric vehicle parking spaces including cabinet, box or enclosure to a conduit linking parking space with electrical service. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 129 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable C303.3 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C403.2.2 [FI27]3 HVAC systems and equipment capacity does not exceed calculated loads. Complies Does Not Not Observable Not Applicable C403.4.1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable C403.2.4. 1.2 [FI38]3 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable C403.2.4. 1.3 [FI20]3 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable C403.2.4. 2 [FI39]3 Each zone equipped with setback controls using automatic time clock or programmable control system. Complies Does Not Not Observable Not Applicable C403.2.4. 2.1, C403.2.4. 2.2 [FI40]3 Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2- hour occupant override, 10-hour backup Complies Does Not Not Observable Not Applicable C405.3.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C407.2 [FI28]1 Commissioning plan developed by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable C404.11 [FI62]1 Service water heating systems, swimming pool/spa water heating systems with all controls shall be commissioned in accordance with Section 407.2. Complies Does Not Not Observable Not Applicable C407.3.2 [FI31]1 HVAC equipment has been tested to ensure proper operation including economizers, VAV fan controls, part load hydronic controls, and lighting control systems. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 1210 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C408.1.1 [FI63]1 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Complies Does Not Not Observable Not Applicable C407.3.4 [FI29]1 Commissioning report completed and certified by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 1211 ofPage Project Title: Data filename: Autosaver Mazda L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington, VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck 12/17/21Report date: 1212 ofPage