Loading...
HomeMy WebLinkAboutSD-23-05 - Supplemental - 0760 Shelburne Road (47)DDDDDDOH OH OH 21 3 214 2 1 6 217213214212211215216214 2 1 2 213 21 1 216217213215212210214213211212210210212211213215217216214208209218219210211213212216214218217210209209210211212208SBSBSBSBSBSBSBSBSBSBSBSBSBSBSBSBSBSBSB SB SB SB SB SB SB SB SB SB SBSBSBSB SBSBSBSBSBSBSBSBSBSB10 ' 1-STORY BUILDING 1-STORY BUILDING SHELBURNE ROAD (U.S. ROUTE 7)SWIFT STREET D D D D D D D D DDD D D D D RIM = 209.0 18" RCP iIN(E) = 202.2 18" RCP iIN(S) =201.3 18" RCP IOUT(W) = 200.6 RIM = 210.8 15" RCP iIN(N) = 204.1 12" RCP iIN(E) =204.3 18" RCP iOUT(W) = 203.9 1-STORY BUILDINGWWWWWWWWWWWW W W W W W W W W W APPROX. LOCATION PER DIGSAFE MARKINGS EX. 8" WATER MAIN APPROX. LOCATION EX. 6" WATER MAIN (TO BE VERIFIED) CROSSWALK SIGNAL POLE LEGAL LOAD LIMIT SIGN UTILITY COVER CONCRETE FOOTING FOR ROUTE 7 OVERHEAD LANE ASSIGNMENT SIGN RIM = 207.9 SUMP = 203.1 18" RCP iOUT +/- 202.7 GUPUPUPUPUPUGUG UGUG45'-8"78'-10"SOL. #3 - 75"BUILT-IN TPCONTROLS FINANCIAL INSTITUTION ±3,350 SF S P E ED TA B L E MULTIFAMILY RESIDENTIAL 27 DU FFE 217.0 BFE 207.0 DA 3 BIO DA 1 BIO FDFDFDFDFDFDFD FD FDFDFDFDFDFDFDFDFDFDFDFDRDD DA 7 BIODD MIXED USE ± 3,240 SF 1ST FLOOR: COMMERCIAL 2ND FLOOR: 3 DU FFE 212.0 FFE 212.0 DDDDDDDDD D D D D D DDDD DD210209211212211210 209208213214216 21 5213 2 1 1 212209 210 211211 210212213213215 216 215216216.5 2172152162 1 4 21821821721 5209206205.521221 3 W W W W WWWWWWWWSSSSSSSSSSSSMH #1 RIM = 215.75 8" iIN = 207.27 6" iIN = 207.5 8" iOUT = 207.17 NEW 8" iIN = 207.0 6" iOUT = 209.0 SMH #2 RIM = 210.95 6" iIN (2) = 207.95 8" iOUT = 207.85 6" iOUT = 209.2 6" iOUT = 208.5 FD FD DD D 8" SDR 35 P V C s =0.004 ft./ft. DMH 2 RIM = 212.0 18" iIN (E) = 201.49 18" iIN (S) = 201.49 18" iOUT (NW) = 201.39 FILTERRA INTERNAL BYPASS BIOSCAPE 4'X6' MEDIA BAY CURB INLET = 214.5' 8" iOUT = 211.3' 4" FOOTING DRAIN ASSUMED INV = 205.0 FILTERRA PEAK DIVERSION 6X10' MEDIA BAY CURB INLET = 210.5' 12" iOUT ~ 207.09' DMH4 RIM = 211.3 12" iIN (E) = 206.0 18" iIN (S) = 201.86 18" iOUT (N) = 201.76 OUTLET STRUCTURE 1 18" OVERFLOW GRATE = 215.75 12" iOUT = 212.0 OUTLET STRUCTURE 2 18" OVERFLOW GRATE = 209.83 12" iOUT = 206.0 FILTERRA INTERNAL BYPASS BIOSCAPE 4X6' MEDIA BAY 6" iIN = 210.5 6" iOUT = 207.8' OUTLET CONTROL STRUCTURE 4 RIM = 211.5 6" iIN (S) = 206.3 18" iOUT (W) = 206.3 FILTERRA INTERNAL BYPASS BIOSCAPE 4'X6' MEDIA BAY PARKING LOT CURB INLET = 208.4' NW CORNER INLET (TOP OF MEDIA) = 207.6' 8" iOUT ~ 205.2' DMH 1 RIM = 210.5 12" iIN (NE) = 205.0 18" iIN (E) = 201.15 18" iOUT (NW) = 201.05 NEW 18" iIN = 201.0 DMH 5 RIM = 211.85 12" iIN (E) = 202.39 6" iIN (FOOTING DRAIN) = 204.0 WITH FLAPPER VALVE AT END 8" iIN (W) = 202.39 18" iOUT (N) = 202.29 OUTLET STRUCTURE 3 18" OVERFLOW GRATE = 206.75 12" iOUT = 202.5 DMH 6 RIM = 209.0 8" iIN (S) = 204.0 8" iOUT (E) = 203.9 EXTENDED DETENTION THREE - 48" HDPE X 80' INVERT = 206.3 FILTERRA INTERNAL BYPASS BIOSCAPE 6'X6' MEDIA BAY CURB INLET = 211.0 8" iOUT = 207.8' CURB INLET = 208.4 CB1 RIM = 212.0 12" iOUT = 210.75 DMH 3 RIM = 214.6 12" iIN (E) = 210.0 8" iIN (S) = 209.17 18" iOUT (W) = 204.17 TRENCH DRAIN AT ENTRANCE TO GARAGE WITH DEEP SUMP AT OUTLET (SEE DETAIL) GRATE = 207.0 6" ROOF DRAIN iOUT = 215.75 4" C900 DR14 1.5" C901 CTS POLY 4" TAPPING VALVE (TYP) 1.5" CURB STOP (TYP)8" C900 DR148" TEE AND GATE VALVE (TYP)216210211209CB2 (DEEP SUMP) WITH CURB INLET 12" iIN = 209.8 12" iOUT = 209.7 POTENTIAL FUTURE 10' x 6' GENERATOR LOCATION UP UP UPUP6" ROOF DRAIN 8"X6"X6" TEE, 6" DI STUB, GATE VALVE AND FIRE PROTECTION HYDRANT, REDUCE TO 6" C900 AFTER TEE TO BUILDING 13'6" C900 DR144" C900 DR14 DOMESTIC SERVICE WITH 4" GATE VALVE 6" C900 DR14 FIRE SERVICE PEASTONE DIAPHRAGM (TYP.) 10' x 12' TRANSFORMER w/SCREEN FENCE IF REQ'D BY GMP Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions No. 8917 CIVILP ROF ESSIONAL E N G INEERL ICEN S E DJENNIFER ANN DESA U T E LSSTA TE O F VER M ONTField Book: For Local Permitting Only 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. 0 Feet Graphic Scale 20 40 60 15°±VT GridMagnetic  PARCEL ID: 1540-00760 SPAN: 600-188-10694 Utility Plan C3-01 01/20/2023 1" = 20' 22-523 PJM CMJ JAD   Shelburne & Swift 760 & 764 Shelburne Rd. & 31 Swift St. South Burlington, VT "I HEREBY CERTIFY THAT, IN THE EXERCISE OF MY REASONABLE PROFESSIONAL JUDGMENT, THE DESIGN RELATED INFORMATION SUBMITTED WITH THIS APPLICATION IS TRUE AND CORRECT AND THE DESIGN INCLUDED IN THIS APPLICATION FOR A PERMIT COMPLIES WITH THE VERMONT WASTEWATER SYSTEM AND POTABLE WATER SUPPLY RULES." (REF. ENVIRONMENTAL PROTECTION RULES CHAPTER 1 §1-306 (b)). LAST REVISED 02/25/2020 1 02/09/2023 JADPlan Revisions 2 02/16/2023 CMJUtilities 3 05/15/2023 CMJStaff Comments