Loading...
HomeMy WebLinkAboutAgenda 06_SD-23-11_1200 1220 Dorset St_Douglass_PPFP #SD-23-11 CITY OF SOUTH BURLINGTON DEVELOPMENT REVIEW BOARD SD-23-11_1200 Dorset St_1200 Dorset St LLC_PP_FP_2023-08- 01.docx DEPARTMENT OF PLANNING & ZONING Report preparation date: July 26, 2023 Application received: June 28, 2023 1200 Dorset Street – 1200 Dorset, LLC Preliminary & Final Plat Application #SD-23-11 Meeting Date: August 1, 2023 Owner Highland Development Company, LLC 63 Kristie Lane Jericho, VT 05465 Applicant 1200 Dorset, LLC 63 Kristie Lane Jericho, VT 05465 Property Information Tax Parcels 0570-01200 Southeast Quadrant-Neighborhood Residential Zoning District Parcel size: 1.29 acres Engineer Civil Engineering Associates 10 Mansfield View Lane South Burlington, VT 05403 Location Map #SD-23-11 PROJECT DESCRIPTION Preliminary and final plat application #SD-23-11 of Casey Douglass to amend a previously approved 5.52 acre 6-unit planned unit development. The amendment consists of subdividing lot 6, developed with a single family home and barn, into two lots of 0.69 acres (Lot 6A) and 0.60 acres (Lot 6B) for the purpose of demolishing the existing single family home and barn and constructing a new single family dwelling on each lot, 1200 Dorset Street CONTEXT The property is located within the 5.52 acre Foulsham Hollow Planned Unit Development, also known as the Heald Subdivsion, which was approved in late 2001 with application #SD-01-59. The decision at that time was very brief, and generally approved the plans as presented, with minor waivers to reduce the required lot frontage. There is no longer a required minimum lot frontage in this zoning district. It also included a condition that the existing home at 1200 Dorset Street be reconfigured to have its driveway access off Foulsham Hollow Road. The City is in possession of an irrevocable offer of dedication for the roadway but has not accepted the roadway. COMMENTS Development Review Planner I Marty Gillies and Development Review Planner Marla Keene, hereafter referred to as Staff, have reviewed the plans submitted by the applicant and offer the following comments. Numbered comments for the Board’s attention are in red. The application is subject to zoning district and dimensional standards, subdivision standards, general planned unit development standards, site plan and conditional use review standards, the general regulations of Article 3 and the supplemental regulations of Article 13. A) ZONING DISTRICT AND DIMENSIONAL STANDARDS Dimensional standards include a minimum lot size of 9,500 sf for a single family home, 20% building coverage and 40% lot coverage, and 20 ft, 10 ft, and 30 ft front, side, and rear setbacks, respectively. As through-lots, the proposed lots will have a front lot line on each of Foulsham Hollow Road and Dorset Street, and no rear lot lines. Additionally, the dimensional standards include a maximum building height for structures with pitched roofs of 28 feet. 1. Staff recommends the Board include a condition that the development on each of the proposed lots meets the dimensional standards of the Southeast Quadrant – Neighborhood Residential zoning district. The applicant is proposing density above the inherent base density of the parcel proposed to be subdivided. Therefore the applicant required to employ the use of one Transfer Development Right, discussed under section 15.A.11(A)(3) below. Transfer Development Rights, or TDRs, are governed by Article 19 of the LDRs, which regulates where TDRs can sent from, where TDRs can be applied (or ‘received’), and the processes by which TDRs are calculated, transferred, and recorded. The applicant is proposing to purchase a TDR from a property in the SEQ-NRP zoning district for receipt at the subject parcel in the SEQ-NR zoning district. Staff considers that the standards of Article 19 as they pertain to the use of this TDR have been met. B) SUBDIVISION STANDARDS 15.A.04 Classification A. Subdivision Classes. #SD-23-11 For purposes of these Regulations, subdivisions of land shall be classified as by the Administrative Officer as follows: 1) A Minor Subdivision, to be reviewed under Section 15.A.07, which is limited to: a. The subdivision of an existing lot, tract or parcel of land into two lots, including the parent or retained lot, if the lot to be created is less than two times the minimum lot area for the district in which it is located, and either has required street frontage, or shares highway access with the retained lot; or b. A lot line adjustment or lot merger which does not meet the requirements for administrative approval under Section 15.A.03. 2) A Major Subdivision, to be reviewed under Sections 15.A.06 and 15.A.07, which includes a subdivision of land that involves any of the following: a. The subdivision of an existing lot, tract or parcel of land into two lots, which does not qualify as a minor subdivision under (A)(1); b. The creation of three or more lots through the subdivision or re-subdivision of an existing lot, tract, or parcel; c. The installation or extension of one or more streets; d. The extension of any off-tract municipal or governmental infrastructure, facilities, or other improvements; or e. A Planned Unit Development (PUD) under Article 15.C, to be reviewed by the DRB concurrently with subdivision review. This application will be considered a Major Subdivision because the lots to be subdivided are each larger than two times the minimum lot area in the applicable zoning district. 15.A.11 General Standards A. Development Suitability. The applicant must demonstrate that the land to be subdivided is physically suited for its intended use and the proposed density or intensity of development, and that the proposed subdivision will not result in undue adverse impacts to public health and safety, environmental resources as identified and regulated under Article 12, neighboring properties and uses, or public facilities and infrastructure located on or within the vicinity of the land to be subdivided. (1) Physical Site Constraints. Land that is physically unsuited for development, including land that is characterized by periodic flooding, poor drainage, shallow soils, landslides, environmental site contamination or other known physical hazards or constraints, must not be subdivided for development unless the applicant can demonstrate that such limitations can be overcome, remediated, or mitigated as necessary to allow for subsequent development. Staff considers there to be no known physical site constraints on this property, as the presence of manmade steep slopes does not constitute an Environmental Hazard. As such, Staff considers this criterion to be not applicable. (3) Buildable Area Calculations. The allowed number of building lots or dwelling units within the subdivision shall be calculated based on the Buildable Area of the parcel or tract to be subdivided except as otherwise specified for a Transect Zone Subdivision under Article 8, a Planned Unit Development under Article 15.C; and as provided for the transfer of development rights under Article 19, or affordable housing offsets, bonuses, or incentives under Article 18. The project is located in the SEQ-NR zoning district, which has an inherent density of 1.2 units per acre, which may be increased to 1.8 units per acre with the transfer of development rights or through the use of inclusionary zoning. Specifically, the 1.29 acre lot 6 has an inherent density of #SD-23-11 1.55 units, which may be increased to 2.32 units through the use of transferred development rights or inclusionary housing. The applicant has indicated their intention to purchase development rights and has provided an executed option agreement for 1 transfer development right, or 0.83 acres. The applicant must record the purchase and use of the transferred development right prior to issuance of a zoning permit for a second home on the subdivided land. The LDRs prohibit transfer of less than one full development right, or 0.83 acres. Transfer development rights are discussed in LDR Article 19 and are summarized in the Zoning District & Dimensional Standards section above. C. Development Context 1) Overlay Districts There are no Overlay Districts applicable to this parcel. 2) Multiple Districts This parcel is located entirely within the SEQ-NR zoning district. 3) Compliance with Other Regulations All other regulations, ordinances, and standards are either entirely inapplicable to this project or not presently applicable to this project – for example, the applicant will have to pay Impact Fees prior to issuance of a Zoning Permit for either proposed new single-family home, but those Fees cannot be calculated until the applicant has provided a final bedroom count and square footage for the proposed homes. As such, the Impact Fee Ordinance is not presently applicable. 4) Compliance with an Approved Master Plan There is no approved Master Plan governing this parcel. D. Development Connectivity The applicant must demonstrate that the subdivision, to the extent physically feasible, is configured and laid out to maximize connections with adjoining parcels and neighborhoods, and to avoid creating isolated and disconnected enclaves of development, except where necessary to separate incompatible land uses, or to avoid undue adverse impacts to resources identified for protection under Article 12. Accordingly, the applicant must demonstrate that the subdivision is laid out to connect with and extend existing and planned streets, sidewalks, recreation paths, transit routes, and utility and greenway corridors located adjacent to or within ½-mile of the subdivision, or as indicated on the City’s Official Map. Off-site improvements necessary to serve the proposed subdivision must be provided in accordance with 15.A.18. The proposed amendment to the existing PUD is a subdivision of one lot into two, and includes the closing of a curb cut along Dorset Street in favor of a proposed curb cut on Foulsham Hollow Road that will serve both lots. There are no other impacts of the proposed amendment to the PUD that affect compliance with this criterion. 15.A.12 Resource Protection Standards There are no identified Natural Resources or Environmental Hazards on this property. As such, this section does not apply to this application. 15.A.16 Blocks and Lots A. Purpose. The layout and configuration of blocks and building lots in relation to the street network establishes the overall pattern of development, including the creation or extension of walkable, pedestrian-friendly neighborhoods and mixed use developments. As such, the configuration of blocks and building lots represent a fundamental component of subdivision design. Accordingly, the applicant must demonstrate that the proposed subdivision incorporates: #SD-23-11 (3) Block faces and building lots that, where feasible, are oriented to maximize solar access and gain; (4) Regularly shaped building lots that front on, and minimize lot frontage or width along abutting streets; Staff has included these elements of the Blocks and Lots purpose statement as a guide to the Board in their discussion of the specific standards outlined below. C. Lots. All lots must be laid out to logically relate to topography and their intended use or purpose. Building lots must be laid out within existing and planned street and block configurations, in such a way that they can be developed in full compliance with their intended use and these Regulations. Unless otherwise specified under these Regulations as applicable to the subdivision: (7) Unless otherwise specified under these Regulations, building lots must have sufficient developable area to accommodate proposed building types, associated yard or other required open space areas, site drainage, utilities, or other improvements required under these Regulations, including site plan standards under Article 14. Staff considers the applicant has demonstrated that these lots are buildable, though Lot 6A will require an access easement over Lot 6B. (8) Unless otherwise specified under these Regulations, building lots must have sufficient developable area to accommodate proposed building types, associated yard or other required open space areas, site drainage, utilities, or other improvements required under these Regulations, including site plan standards under Article 14. Both proposed building lots are large enough and unencumbered enough to accommodate all improvements required by the Regulations and proposed as part of this application. (9) A building lot generally must be rectangular in shape, with side lot lines that are perpendicular or radial to the abutting street, and rear lot lines that parallel the street, except as necessary to accommodate existing rights-of-way or other physical site constraints (see Figure 2-1, Lots, Yards and Lot Lines). Irregular or oddly shaped building lots, including flag and through lots, are prohibited, except for: (a) A flag lot, with a minimum of fifteen (15) feet of frontage on the abutting street, as necessary to accommodate a back-lot subdivision and infill development within an existing subdivision, block pattern, or development; (b) A triangular or trapezoidal building lot defined by abutting streets that otherwise has sufficient street frontage and lot area to meet minimum lot requirements; or (c) A through lot with frontage on two parallel or intersecting streets that cannot be further subdivided under minimum lot requirements, provided that front setback requirements can be met on both streets. Staff considers the proposed lot lines to be laid out to best meet these requirements, given the existing street rights-of-way. (10) Building lots should be oriented and configured to minimize lot width (frontage) along the street. The preferred building lot width to depth ratio is 1:2; however, a ratio of 1:1 to 1:5 may be allowed as necessary to accommodate physical site constraints, stormwater drainage, or rear lot access and parking. Lot 6B does not meet the required lot ratio of 1:1. However, it is not possible to subdivide the lot into the maximum of two lots and still meet the required ratio, therefore Staff recommends the Board waive this dimensional standard as permitted under 15.C.07 due to physical site limitations. #SD-23-11 (11) Building lots must be configured to avoid or, where necessary, minimize rear lot lines that abut side lot lines. Unless otherwise specified under these Regulations, corner lots must be configured to meet lot frontage and front setback or build-to-zone requirements on all abutting streets. Lot 6B is a corner lot and is proposed to meet setback requirements. Lot 6A is not a corner lot. Its northern property line is a side lot line, and abuts what will also be a side lot line if the proposed development at 1170 & 1180 Dorset Street is approved by the Board. Both proposed lots have two fronts and therefore no rear lot lines. Staff considers the proposed configuration of the lots to be appropriately configured to minimize rear lot lines that abut side lot lines. (12) Temporary or permanent surface parking lots, where parking is the principal use, must at minimum meet the minimum lot area requirement applicable to building lots, to allow for future parking lot redevelopment. Such lots must also be shown on subdivision plans and plats submitted with the application. Parking is not the principal use of either of the proposed new parcels – as such, this criterion does not apply. 15.A.17 Mix of Dwelling Unit Types A. Mix of Dwelling Unit Types and Architectural Features A mix of dwelling unit types (i.e. cottage, single family, two-family, small multi-family, townhouse, etc. etc.) and mix of architectural features and styles must be provided within neighborhoods and developments. These must be mixed within blocks, along the street and within neighborhoods rather than compartmentalized into sections of near-identical unit types. An applicant for a subdivision shall submit a plan demonstrating how this mix will be achieved for the Development Review Board’s consideration at the preliminary plat stage. Where a Planned Unit Development approved under Article 15C establishes standards for a mix of dwelling unit or building types, those standards shall supersede these herein. The proposed subdivision is for two homes. The existing homes on Foulsham Hollow Road are generally the same architectural style. Given the small number of homes proposed, Staff considers no specific restriction on dwelling unit types or architectural features beyond those specified in 13.17 Residential Design for New Homes to be appropriate for this subdivision. 15.A.18 Infrastructure, Utilities, and Services A. Capacity of Community Facilities, Utilities, and Services The applicant must demonstrate that the proposed subdivision and development will not exceed the existing or planned capacity of, or cause a disproportionate or unreasonable burden on City facilities, utilities and services, including: • Public schools, • Police, fire protection and ambulance services, • Street infrastructure and maintenance, • Parks and recreation facilities, and • Water supply, wastewater disposal, and stormwater management systems and infrastructure. The applicant will be required to pay Impact Fees to offset the impact of this development on the capacity of all of the five enumerated services. B. Potable Water Supply and Wastewater Systems The applicant must demonstrate that adequate potable water supply and wastewater facilities exist #SD-23-11 to serve the subdivision at buildout, and for each phase of development, in accordance with the following: The project is served by a private wastewater pump station that is approved to remain private. Staff recommends the Board require the applicant to demonstrate adequate capacity in the existing pump station, or a plan to make the necessary upgrades. The Director of Public Works reviewed the plans on 7/19/2023 and offers the following comments.  I’d like to better understand the existing wastewater infrastructure that this project proposes to utilize. Does the engineer have as-built information for the pump station and force main that will accept wastewater from this subdivision? This includes information related to where the force main heads after it leaves the property as it heads north?  There also appears to be a force main located on the east side of the Foulsham Hollow subdivision. I’m not seeing these easements shown on the plat. 2. Staff recommends the Board direct the applicant to address the comments of the Department of Public Works Director prior to closing the hearing. 1) A subdivision within the City’s public water supply and wastewater system service areas must be connected to municipal systems unless physical constraints preclude such connection. For the sewer system this includes any area located within the City Center Service Area, or within 200 feet of an existing sewer line. Each building lot within the subdivision must be served by the municipal system as required under the City’s Water Ordinance, and South Burlington Ordinance Regulating the Use of Public and Private Sanitary Sewerage and Stormwater Systems, as most recently amended. The two lots proposed to be created will both be on public water and wastewater, although the project will use an approved private wastewater pump station. 6) Sufficient water system pressure must be maintained throughout the subdivision, to serve all building lots and to provide for adequate fire protection. The Superintendent of the South Burlington Water Department noted that the FFEs for both newly proposed single-family homes are above the maximum elevation that can be supplied from the Dorset Street water storage tank and meet the minimum water pressure of 35 PSI. 3. Staff is aware of previous situations in which the South Burlington Water District has permitted the development of homes with sub-standard water pressure. As such, Staff recommends the Board direct the applicant to work with the Director of Public Works and South Burlington Water Department Superintendent to ensure that water pressure will be adequate for the proposed homes. Additionally, South Burlington Water Department Superintendent reviewed the plans on 7/19/2023 and offers the following comments: 1. The South Burlington Water Department (SBWD) cannot confirm the existence of the existing ¾” water service that is to supply these two homes. 2. The ¾” service, if it does exist, is undersized for supplying two homes with each home being serviced by a proposed 1” copper water service. The existing line, if it does exist, must be excavated at the water main, shut off at the corporation, disconnected from the main, and a new, appropriately sized tap and line installed to service these two new homes. Consideration for fire protection, if required by the fire department must be included in sizing all service lines to these homes. 3. There must be separate curb stops on each proposed service line where they tee. There must also be a main curb stop on the edge of the road. Access must be provided to the SBWD to each curb stop for disconnections or shut off needs. The SBWD does not own any water line outside of the City ROW. #SD-23-11 4. This information is provided for information and engineering purposes. Per the Vermont Department of Public Safety Division of Fire Safety, the current adopted code is the International Plumbing Code (IPC), 2015 Edition. The 2015 IPC requires 20 psi minimum for toilets (“water closet, tank, close coupled or one piece), which is the controlling factor for establishing the minimum required pressure for internal plumbing (assuming the toilets do not have flushometer valves). Site plans indicate that the preconstruction grades of the proposed homes range between 434’ and 436’. The SBET low operating level is 515’, and the highest elevation in the City that can still provide 35psi is 435’. The upper floors of some homes are likely to experience lower water pressures than what customers are accustomed to. Additional data from the applicant will be required to confirm there are adequate pressures for second floor plumbing fixtures. Furthermore, if residents intend to install water booster pump stations within the proposed units, approval must be obtained by the Secretary in accordance with the VT Water Supply Rule. Written permission from the DEC for in-home booster pumps received by the developer must be provided to the SBWD. 5. The following note must be provided on all plan sheets and detail pages: All water lines and appurtenances shall be installed in accordance with the Champlain Water District Specifications and Details for the Installation of Water Lines and Appurtenances, current edition, henceforth CWD Specifications.” 6. The project shall be constructed, completed, maintained, and operated in accordance with the approved plans. No changes shall be made in the project without the written approval of the appropriate CWD Division. 7. When a pipe material is specifically noted on the approved project drawings, the contractor/developer shall not have the option of utilizing any other pipe material. 8. Curb boxes located in roadways or sidewalks shall be placed inside a gate valve box top section with cover and brought to final pavement/concrete grade with one non-adjustable paving riser per #10 above. 9. The appropriate CWD Division shall be notified in advance to inspect all mechanical joint fittings, main line taps, appurtenances, thrust blocks, and water line crossings prior to occurrence of back filling. 10. CWD continues to allow for “approved equal” products but they shall be reviewed by the appropriate CWD Division. 11. Connections will only be permitted between the hours of 7:00am and 3:00pm on regular Champlain Water District business days, except Fridays. All connections must be completed by 3:00pm; connections that cannot be completed by 3:00pm may be suspended and completed the following business day. A suspended tap may entail back filling the excavation until the following day. CWD personnel have the authority to suspend connections that they deem cannot be completed within the time period stated above. 12. No water lines shall be installed after November 15 or before April 1 without prior approval of the appropriate CWD Division. The appropriate CWD Division may restrict work before November 15 and after April 1 during adverse weather conditions. CWD does not allow excavating water mains and service lines during the winter months except by special permission. 13. Record drawings, prepared by a VT licensed Professional Engineer shall be provided to the appropriate CWD Division in pdf. and Auto-CAD format. Drawings shall include ties to all gate valves and curb stops to sub-meter accuracy. 4. Staff recommends the Board direct the applicant to address the comments of the South Burlington Water Department Superintendent prior to closing the hearing. Comments 4 – 13 are standard comments and no action is required. #SD-23-11 C. Fire Protection The subdivision must be laid out to ensure that adequate fire protection can be provided in accordance with City specifications. a) Subdivision layout and design must also comply with applicable City and state public safety and fire codes in effect at the time of application, including standards for minimum separation distances between structures, street width, water flow and pressure, fire hydrant installation, sprinkler systems, and emergency vehicle access. b) Fire hydrants connected to the municipal water system must be located and designed to meet City specifications, as recommended by the Department of Public Works and City Fire Marshal. For a subdivision that is not connected to the municipal system, the DRB may require the subdivider to install hydrants, fire ponds or other measures necessary to provide adequate fire protection, as recommended by the Fire Marshall. The Fire Marshal reviewed the plans on 7/18/2023 and offers the following comments: It is not clear as to whether the easement is a driveway to Lots A & B or just an underground utility corridor. If it is a driveway, Lot 6B as shown will be required to have a NFPA 13D sprinkler system installed as the distance to the front door from Foulsham Hollow Road is greater than 150 feet. Also, it is not clear that an emergency vehicle can transit the curve in the easement/driveway to access the bldg. in 6B. 5. Staff recommends the Board direct the applicant to address the relevant comments of the South Burlington Fire Marshal prior to issuance of a Zoning Permit. D. Stormwater Facilities The applicant must demonstrate that stormwater management system serving the subdivision has been designed to meet City standards and specifications under Article 13 of these regulations and the South Burlington Ordinance Regulating the use of Public and Private Sanitary Sewerage and Stormwater Systems. The South Burlington Stormwater Superintendent reviewed the plans on 7/1/2023 and offers the following comments: 1. As this is an amendment to an existing planned unit development with more than ½ acre of existing impervious, and the applicant is proposing more than 5,000 square feet (12,595 square feet proposed) of new or redeveloped impervious, the applicant is required to provide stormwater treatment for the entirety of the new and redeveloped impervious on Lots 6A and 6B. This stormwater treatment must meet the standards laid out in the Land Development Regulations Article 13.05 – Stormwater Management. Please provide information on how this site will meet stormwater treatment standards. 2. Staff recommends the DRB include language requiring the applicant to properly maintain EPSC measures for the duration of site work and construction. 6. Staff recommends the Board direct the applicant to address the comments of South Burlington Stormwater Superintendent prior to closing the hearing. E. Utilities and Services. F. Street and Sidewalk Lighting. Staff considers that, because the project doesn’t affect the existing roadway, these standards are not applicable to this project. G. Renewable Energy Facilities #SD-23-11 The applicant must demonstrate that, to the extent physically feasible, reasonable, and as appropriate to its development context, the subdivision has been designed to incorporate best practices that maintain access to and use of renewable energy resources, e.g., to include one or more of the following as indicated on subdivision plans and plats: (1) Street and building lots that are oriented to maximize solar access and gain, for passive solar construction or rooftop solar installations. (2) Parking lots or structures that are designed and constructed to accommodate electric vehicle infrastructure, including charging stations and solar canopies or rooftop solar installations. (3) One or more suitable open areas (“solar lots”) within the subdivision that are specifically designated for a ground-mounted community or neighborhood solar installation. (4) Solar access easements, as necessary to maintain solar access across adjoining building lots or properties. (5) Covenants, deed restrictions or other legal mechanisms that require “solar-ready” construction within the subdivision. Staff considers that the proposed lot configuration does not adversely affect the ability of the proposed homes to maximize solar access and gain. C) PUD & GENERAL PUD STANDARDS 15.C.04 PUD Standards Applicable to All PUD Types A. Conformance with the Comprehensive Plan The proposed PUD must conform to the City’s Comprehensive Plan in effect at the time of application. Conformance with the plan in this context means that the proposed PUD must: 1) Advance any clearly stated plan policies and objectives specific to the type and location of the proposed development; 2) Incorporate preferred settlement patterns, including future land uses, densities and intensities of development referenced in the land use plan, as implemented through planned unit development provisions specific to each PUD type. 3) Incorporate, as applicable, planned facilities, services and infrastructure identified in the utilities and facilities plan, as implemented under the City’s adopted Capital Improvement Program (CIP) and Official Map. The proposed subdivision constitutes an amendment to an existing PUD, not a newly proposed PUD. Staff considers that the proposed amendment to the existing PUD does not affect the existing PUD’s level of conformance with the City’s Comprehensive Plan. B. Conformance with the Master Plan Each phase of a PUD developed in one or more phases must conform to the PUD Master Plan, as approved or amended by the DRB under Article 15.B, including the approved development plan, phasing schedule, buildout budget, management plan, and any associated development agreements or conditions of master plan approval. As noted above, the proposed subdivision constitutes an amendment to an existing PUD. The existing PUD was developed without a Master Plan, as that was not required at the time this PUD was originally approved. As such, there is no Master Plan with which this proposed subdivision must conform, so this criterion is not applicable to this project. C. Compliance with Regulations #SD-23-11 The provisions and standards specific to a PUD under this Article supersede underlying zoning district, subdivision, and site plan standards. In no case, however, shall the provisions or standards specific to a PUD supersede the Environmental Protection Standards of Article 12. Notwithstanding the supersession of the underlying zoning district, subdivision, and site plan standards, any application that indicates a density increase that exceeds the Assigned Density of a parcel shall require a TDR under Article 19. The applicant is not proposing any impacts to Natural Resources or Environmental Hazards beyond those detailed below under Section 12.03 regarding Steep Slopes. The applicant is proposing a density increase that exceeds the Assigned Density of this parcel but is using a TDR, as required by this criterion and governed by Article 19. As such, Staff considers this application to comply with the relevant regulations and considers this criterion met. D. Development Density E. Transition Zone F. Allowed Uses G. PUD Dimensional Standards H. Street, Building, and Civic Space Types I. Solar Siting Preferences J. PUD Design Standards As an amendment to an existing PUD, and not a newly proposed PUD, the seven standards above are not applicable to this project. 15.C.07 General PUD A. Authority and Limitations B. General PUD Description, Purpose, and Characteristics C. Applicability A General PUD is an allowed PUD type in the following circumstances: 1) Within the underlying zoning districts listed in Table 15.C-1 for General PUD. 2) For amendments to General PUDs approved under this Section. 3) For minor amendments to existing PUDs reviewed and approved under the LDRs in effect until November 10, 2021, the final subdivision approval for which has not expired, regardless of zoning district. a. An amendment shall be considered “minor” if it does not significantly alter the overall intent or scale of the PUD, or the relationship of the approved PUD to its surroundings. A minor amendment may incorporate additional land not in the PUD as previously approved, but only to the extent that the additional land does not cause the PUD to exceed other requirements of this section. Staff considers the proposed subdivision of one 1.29-acre lot with a previously approved PUD into two lots to be a ‘minor amendment’ to that PUD, as per the language of this criterion. As such, a General PUD is an allowed PUD type, as per this criterion. D. Conformance with PUD Standards In addition to the specific standards under this Section, all standards in Section 15.C.04 shall also #SD-23-11 apply. Application and review process for a General PUD is governed by Section 15.C.03. See 15.C.04 above for discussion of all relevant standards of that Section. E. Context For planning and design purposes, “Planning Area” is defined as the area within ¼-mile of the lot or parcel to be developed, as measured from the lot line or delineated PUD boundary. F. General PUD Compatibility and Context Analysis 1) Compatibility. PUD compatibility with the Planning Area, as determined from a detailed analysis of the Development Context, shall be a primary consideration in General PUD project design, and for DRB review and approval. 2) “Development Context” is defined to include: a. The prevalent or recurring pattern and form of development within the Planning Area, including established street grid and streetscape elements, blocks, lots, buildings and yard areas, civic spaces, and parking arrangements, and b. The character of the Planning Area, as defined by: i. The planned character of an area planned for redevelopment by the City as identified in the Comprehensive Plan; ii. Approved, to-be-built or recently built (within ten (10) years) development projects in the Planning Area; iii. Any updates to the underlying zoning district(s) in the Planning Area within the preceding ten (10) years; or iv. Zoning district purpose statements, allowed uses, and district-specific development standards. c. Current zoning purpose statements, uses, and standards only if the DRB finds there is no relevant information under 15.C.07(F)(2)(a) or (b)(i) through (b)(iii), or the DRB finds that there is a clear, established neighborhood street, block, and lot pattern. The Development Context for this project includes the subject PUD, the Planning Area to the south along Medalist Drive, and the Planning Area to the north within a proposed 14-unit PUD. This area is primarily developed in a generic suburban form featuring detached single family homes and duplexes. Some of these structures are on footprint lots; the others are on lots between 0.29 and 0.82 acres in size. This area of the City is identified as a lower-intensity development area. Staff considers that the proposed amendment to the PUD will maintain continuity with the identified Development Context. 3) Context Analysis. The applicant must submit a written Analysis of the Development Context within the Planning Area, which, at minimum, includes the information required for Master Plan review under 15.B.04(C) and: a. Hazards, and Level I and Level II Resources regulated under Article 12. b. Prevalent pattern of land subdivision and development in the Planning Area, as defined by block lengths; lot size and front lot line lengths; front, side, and rear setbacks; building height and coverage; and existing parking arrangements. c. Streetscape elements, including the placement, orientation, and spacing of buildings along the street, existing and planned sidewalks, and existing or planned landscaping, street furniture, and lighting. #SD-23-11 d. Building types and styles, including any prevalent or character-defining architectural features. The applicant has not provided a formal context analysis. Staff considers that no formal context analysis is necessary since the proposed project only constitutes a minor amendment to the PUD and therefore does not affect the context of the PUD or of the greater Planning Area. As such, Staff recommends that the Board waive this requirement for the applicant to provide a Context Analysis as part of this application. G. General PUD Dimensional Standards 1) Relevant subdivision, site plan, zoning district, and applicable overlay district dimensional standards shall form the basis of the design of a General PUD and shall apply unless modified, reduced, or waived by the DRB under (2) below. a. The DRB must find an application meets the requirements of 15.C.07(G)(2) in order to modify, reduce, or waive Site Plan requirements using 14.04(A)(3), Site Plan application requirements using 14.05(G), Subdivision requirements using 15.A.01(B)(3), Scenic Overlay District requirements using 10.02(I)(2), (J), and/or (K). b. The DRB has authority to allow alternative compliance under 15.C.04(C)(3). c. Height restrictions may be modified, reduced, or waived as allowed in underlying zoning districts identified in 3.07(D)(2) by the DRB under (2) below. The standards of review in 3.07(D)(2) shall apply. d. The DRB cannot modify, reduce, or waive standards as listed in 15.C.07(A)(3). As discussed above, the applicant is requesting waiver of 15.A.16.C(9), a standard requiring lots to have a width to depth ratio of at least 1:1. 2) In response to the existing or planned Development Context in the Planning Area, the DRB may modify, reduce, or waive one or more applicable dimensional standards as necessary to: a. Accommodate reductions in the available area associated with infill or redevelopment, that result in insufficient acreage to meet applicable dimensional standards; or b. Allow for more creative and efficient subdivision and site layout and design that advances the purposes of the underlying zoning district and/or the goals of the Comprehensive Plan, particularly in response to existing site limitations that cannot be eliminated; or c. Ensure that the pattern and form of proposed development is compatible with existing or planned Development Context in the Planning Area determined under 15.C.07(F) and to Transition Zone standards in 15.C.04(E); or d. Allow for greater energy efficiency, use of alternative energy, green building design, or otherwise furthering of the South Burlington City Council’s Resolution on Climate Change dated August 7, 2017. Staff recommends that the Board grant the applicant the requested waiver from 15.A.16.C(9). 3) Context shall be determined by the existing or planned Development Context in the Planning Area under Section 15.C.07(F). H. Development Density 1) Development Density regulations and definitions included in Section 15.C.04(D) shall apply to General PUDs. #SD-23-11 2) Development density within a General PUD is determined by maximum development density in the underlying zoning district, except as follows. a. Density can be re-allocated within the PUD area within single zoning districts; b. Additional density may be achieved through either or both Inclusionary Zoning and application of Transferrable Development Rights where specifically authorized by and as regulated by Section 18.01 or Article 19. As discussed above, the applicant is proposing to purchase one (1) TDR to increase the allowable density of the parcel in question to allow for the development of two single- family homes on their own lots. The applicant must follow all standards on Article 19 governing the sale, purchase, and application of TDRs. I. General PUD Design Standards 1) Design Standards. Generally. The design for a General PUD shall comply with existing Site Plan, Subdivision, and Overlay District regulations and standards, but may allow for variations from applicable regulations that respond to and incorporate the development context within the Planning Area and under the specific circumstances listed in Section 15.C.07(G). The applicable standards are addressed herein. 2) Streets. Streets within a General PUD must be compatible with and connect to existing and planned public street, sidewalk, and path networks in the Planning Area. a. Street and block pattern requirements of the Subdivision regulations shall apply unless waived by the DRB under Section 15C.09(G)(4). Street and block patterns are discussed under 15.A.16 above. 3) Parking. Parking design and building location requirements applicable in all underlying zones and districts apply to General PUDs, including all requirements in Section 14.06(A)(2). Staff considers this criterion not to be applicable. 4) Buildings. Buildings and associated building lots within a General PUD must be compatible with the development context in the Planning Area as described under Section 15.C.07(F) and (G). The form and design of the proposed buildings is discussed under 14.06 below. The associated building lots are discussed in 15.A.16 above and 13.17 below. 5) Civic Spaces and Site Amenities. Civic Spaces and/or Site Amenities must be compatible with the existing or planned development context. General PUDs must comply with applicable Civic Space and/or Site Amenity requirements in Subdivision (Section 15.A.16(C)(4)) and Site Plan (Section 14.06(4)). a. Section 15.A.16(C)(4) requirement for minimum 10% of the total buildable area to be civic space lots apply to General PUDs only for PUDs that involve subdivision of land resulting in three (3) or more lots, not including the resulting lots that only contain civic space(s). b. In a General PUD, Civic Spaces required under Subdivision Regulations (Section 15.A.16(C)(4)) and under Site Plan Regulations (Section 14.06(4)) can be satisfied by a combination of Civic Spaces, Site Amenities, or a combination, applied across the PUD area. The proposed amendment to an existing PUD involves the subdivision of one private lot into two private lots to be developed with detached single-family homes and yard #SD-23-11 space. Potential options for this proposed General PUD amendment include private yard space. 7. Staff recommends the Board require the applicant to demonstrate how the required area of civic space or site amenity can be provided with the proposed subdivision by designation of such area on the proposed plans. 6) Housing Mix. In a General PUD with more than four (4) residential dwelling units, a mix of two or more dwelling unit types (as allowed within the applicable zoning district) must be provided as described by Section 15.A.17. Types of dwelling units are differentiated by either housing type under Article 11.C or, within multi-family structures with more than four (4) dwelling units, by number of bedrooms per unit. The proposed amendment to an existing PUD includes the removal of one existing single-family home and the construction of two new single-family homes, for a net gain of one dwelling unit. As noted under 15.A.17 above, Staff considers no specific restriction on dwelling unit types or architectural features beyond those specified in 13.17 Residential Design for New Homes to be appropriate for this project. D) SITE PLAN & CONDITIONAL USE REVIEW STANDARDS 14.06 General Review Standards A. Relationship of Proposed Structures to the Site. (1) The site shall be planned to accomplish a desirable transition from structure to site, from structure to structure, and to provide for adequate planting, safe pedestrian movement, and adequate parking areas. The DRB shall consider the following: (a) Street Frontage. Maintain internally-consistent building setbacks and landscaping along the street. The applicant is proposing to adhere to existing front and side yard setbacks for the two proposed single-family homes and is not proposing to add any landscaping features as part of this application. Street trees are located approximately 100-ft apart. While Staff is not aware of a required street tree spacing outside of the Form Based Code zoning districts, this is an unusually large spacing therefore Staff recommends the Board require the applicant to add a street tree as part of this project to reduce street tree spacing on Foulsham Hollow Road in front of the proposed lots to 50-ft. The City Arborist reviewed the plans on 7/19/2023 and offers the following comments. If trees on site are to be retained, they should be delineated on the plan and a tree protection plan should be included. 8. Staff recommends the Board direct the applicant to address the comments of the South Burlington City Arborist prior to closing the hearing. (b) Building Placement, Orientation. Maintain or establish a consistent orientation to the street and, where a prevalent pattern exists, shall continue the manner in which the site’s existing building foundations relate to the site’s topography and grade. The proposed buildings’ orientation to the street and relationship to the existing buildings in the PUD is discussed in 15.A.16 above and 13.17 below. (c) Transition Contrast in Scale. Minimize and mitigate abrupt contrasts in scale between existing, planned or approved development, and proposed development. #SD-23-11 (d) Pedestrian Orientation. Improve and enhance pedestrian connections and walkability within the area proposed for development. (e) Solar Gain. Orient their rooflines to maximize solar gain potential, to the extent possible within the context of the overall standards of these regulations. 9. Staff recommends the Board include a condition of approval requiring rooflines to have a principal face oriented south in order to maximize solar gain potential. B. Relationship of Structures and Site to Adjoining Area 1) The Development Review Board shall encourage the use of a combination of common materials and architectural characteristics (e.g., rhythm, color, texture, form or detailing), landscaping, buffers, screens and visual interruptions to create attractive transitions between buildings of different architectural styles. The provided elevations and landscaping plan demonstrate that the proposed single family homes will be of relatively similar architectural style to one another and to the adjacent homes on Foulsham Hollow Road. As such, no ‘attractive transitions’ need to be provided as per this section, since the proposed and existing buildings are not shown to be of different architectural styles. However, the elevations are merely concepts. Although the proposed elevations may meet the relevant criteria at this stage of review, they are technically non-binding and therefore could be modified in such a way to reduce compliance with the relevant criteria. 10. Staff recommends the Board require the applicant to enumerate to what characteristics of the conceptual homes the applicant proposes to commit in order to ensure future compliance with this criterion. 2) Proposed structures shall be related harmoniously to themselves, the terrain and to existing buildings and roads in the vicinity that have a visual relationship to the proposed structures. 3) To accomplish (1) and (2), the DRB shall consider: a. Pattern and Rhythm. Update or maintain or extend the overall pattern of development defined by the planned or existing street grid, block configurations, position and orientation of principal buildings, prevalence of attached or detached building types. As discussed in 15.C.07.F above, the proposed amendment to the PUD fits well in the Planning Area and local development context of the existing PUD and surrounding neighborhood. The proposed subdivision will extend the overall pattern of development to include two new lots of typical size for the area, to be developed with buildings of a use and form that is typical for the area. The Board may discuss whether the proposed orientations of the new structures is in line with the existing pattern and rhythm of this area. b. Architectural Features. Respond to recurring or representative architectural features that define neighborhood character, without adhering to a particular architectural style. The proposed homes will be of a similar massing and form to one another and to the other homes on Foulsham Hollow Road. The proposed homes both are both shown on the conceptual elevations as two-story single family homes with pitched dark shingle roofs and attached multi-car garages, like the other homes on the street. 11. Staff reiterates the previous recommendation for the Board to require the applicant to enumerate to what characteristics of the conceptual homes the applicant proposes to commit in order to ensure future compliance with this criterion. c. Privacy. Limit impacts and intrusions to privacy on adjoining properties, including side and back yard areas through context sensitive design. #SD-23-11 The proposed home on Lot 6B has only one immediate neighbor (Lot 6A to the north) and is proposed to be separated from that home by a parking area and a shared driveway. , The home on Lot 6A is proposed to be roughly 15 feet higher in elevation that the home on the lot to the east. There is no landscaping proposed to be retained or installed along that shared lot line. As a proposed single family home adjacent to an existing single family home, Staff considers no additional buffering or screening to be necessary. C. Site Amenity Requirement 1) Sites are required to include a specific minimum area for appropriate Site Amenities. This section does not apply to projects within the City Center FBC District (which are governed by Section 8.08). 2) Applicability. Applications for the following shall be required to provide Site Amenities: a. Any non-residential development over 5,000 SF. b. Additions or expansions exceeding 5,000 SF for existing non-residential structures. c. Any residential development, including conversion of non-residential structures to residential use. This application constitutes residential development and therefore requires provision of a Site Amenity. This requirement and options for meeting it are addressed in 15.C.07.I(5)(b) above. 14.07 Specific Review Standards In all Zoning Districts and the City Center Form Based Codes District, the following standards shall apply: A. Environmental Protection Standards All proposed development shall be subject to the applicable requirements of Article 12, Environmental Protection Standards. As discussed under 15.C.04.C above and 12.03 below, the applicant is not proposing any impacts to Natural Resources or Environmental Hazards beyond those detailed under Section 12.03. As such, Staff considers the relevant aspects of this criterion to be met. B. Site Design Features. All proposed development shall comply with standards for the placement of buildings, parking and loading areas, landscaping and screening, open space, stormwater, lighting, and other applicable standards related to site design pursuant to these Land Development Regulations. The relevant standards that apply to the design of the two proposed lots are comprehensively addressed throughout this Staff Report – Staff considers this criterion to be met. C. Access and Circulation. D. [Reserved for Transportation Demand Management (TDM)] E. Building Form. F. Streetscape Improvements. G. Access to Abutting Properties. Staff considers these criteria not applicable to this two-lot PUD amendment. H. Utility Services. Electric, telephone and other wire-served utility lines and service connections shall be underground insofar as feasible and subject to state public utilities regulations. Any utility installations remaining #SD-23-11 above ground shall be located so as to have a harmonious relation to neighboring properties and to the site. Standards of Section 15.A.18, Infrastructure, Utilities, and Services, shall also be met. All utility connections to the two new single-family homes proposed to be constructed are shown as being underground. As such, Staff considers this criterion to be met. I. Disposal of Wastes. All dumpsters and other facilities to handle solid waste, including compliance with any recycling, composting, or other requirements, shall be accessible, secure and properly screened with opaque fencing to ensure that trash and debris do not escape the enclosure(s). Small receptacles intended for use by households or the public (i.e., non-dumpster, non-large drum) shall not be required to be fenced or screened. No dumpsters or other stationary exterior waste receptacles are proposed as part of this application. Staff considers this criterion to not be applicable. E) OTHER APPLICABLE STANDARDS 12.03 Steep Slopes F. Exemptions 1) Removal of Earth Products. Steep slopes and very steep slopes created by an approved removal of earth products use shall be exempt from the regulations of Section 12.03. 2) Environmental Restoration Projects. Environmental Restoration Projects are exempt from the regulations of Section 12.03. 3) Shoreline Restoration Projects. Projects with the primary purpose of restoring the shoreline of a lake, river, or stream through installation of vegetation and other methods that do not include the installation of structures (e.g., retaining walls), are exempt from the regulations of Section 12.03. The subject property has an area of ‘very steep slopes’ that was created by a previously approved grading activity – as such, this area of ‘very steep slopes’ is exempt from the standards of this section. 13.17 Residential Design for New Homes C. Standards. 1. Building Orientation. Residential buildings must be oriented to the street, to an approved civic space, or to a courtyard. Primary entries for single family and multi- family buildings must face the street, civic space, or courtyard. Secondary building entries may open onto garages and/or parking areas. Buildings should be oriented to maximize living space and windows to the south, east and west. Residential buildings should orient their rooflines to maximize solar gain potential, to the extent possible within the context of the overall standards of the regulations. The building on Lot 6B is proposed to face the cul-de-sac portion of Foulsham Hollow Road., with a front door and entry porch oriented to that portion of the street and a side-facing garage abutting the driveway & additional parking area. At sketch, the Board had asked the applicant to consider modifying the building on Lot 6B to face the straight portion of Foulsham Hollow or face Dorset Street, and to potentially move or reduce the parking area to the north of that building. The orientation of the building on Lot 6A is unchanged from sketch. #SD-23-11 12. Staff recommends the Board discuss whether they are satisfied with the proposed orientation of the proposed homes and indicate whether those proposed orientation are acceptable given the criteria outlined herein. 2. Building Façades. Building facades are encouraged to employ a theme and variation approach. Buildings should include common elements to appear unified, but façades should be varied from one building to the next to avoid monotony. Front porches, stoops, and balconies that create semi-private space and are oriented to the street are encouraged. Residential buildings with rear facades that orient towards a public recreation path should employ rear porches, balconies, or other features to enhance their architectural detail. The applicant has provided sample elevations for the home proposed to be constructed on Lot 6B that include a rear entrance, a rear porch, and several windows along the west façade that faces Dorset Street. The applicant has not provided a sample elevation of the south façade, which faces the straight portion of Foulsham Hollow Road. The north façade of the home proposed to be constructed on Lot 6A includes a rear entrance and a deck and is proposed to be screened via the retention of an existing hedgerow. The west façade of that home has very few architectural details or windows but is also proposed to be screened via the retention of an existing hedgerow. 13. Staff recommends the Board consider whether the proposed samples elevations for the public-facing facades demonstrate compliance with this criterion and require the applicant to make any alterations deemed necessary prior to closing the hearing. Staff further recommends the Board determine which elements of the proposed elevations the applicant must retain in order to ensure compliance with this criterion and include such elements in the decision for this application. 3. Placement of Garages and Parking. For garages with a vehicle entrance that faces a front lot line, the face of the garage that includes the vehicle entrance must be set back a minimum of eight feet (8’) behind the front façade of a single or two-family dwelling. For buildings containing three or more dwelling units, the requirements of Section 14.06A shall apply. This criterion is proposed to be met. Staff recommends the Board affirmatively require compliance with this criterion in its decision for this application. a) The DRB or Administrative Officer may waive this provision for garages with vehicle entries facing a side lot line, provided that (i) the garage is visually integrated into the single or two-family dwelling; and (ii) the face of the garage that is oriented to the street is no more than eight feet (8’) in front of the front façade of the house. b) Rear alleys are encouraged for small lot single-family houses, duplexes and townhouses. Rear alleys do not appear to be feasible for the proposed lot configuration. As such, Staff considers that this criterion does not apply to this project. 4. Garages as percentage of front façade. Front-facing garages that are part of a principal building shall not exceed 40% of the linear width of the building’s front façade. The sample elevation of the home proposed to be constructed on Lot 6A appears to be just below this limit, with the garage taking up 39.94% of linear width of the front façade. The applicant has not provided front elevations for the home proposed to be constructed on Lot 6B, but that garage is proposed to be side-facing, and therefore is exempt from this criterion. Staff recommends the Board affirmatively require compliance with this #SD-23-11 criterion in its decision for this application. 18.03 Housing Preservation If an existing home is to be removed, Section 18.03 requires a replacement home be constructed & restored to residential use within two years of demolition of the existing home. If the two year timeline cannot be met, additional requirements for replacement housing apply, including:  that the replacement housing have the same number of bedrooms as the removed home,  that it be offered for sale at the same rate as the removed home or as may qualify as an inclusionary housing, and  that the applicant provide a bond in the amount equal to 25% of the value of the removed home. The applicant has indicated an estimated construction schedule in which construction on the house on Lot 6A may not be completed until 2025, and Lot 6B in 5 to 20 years. The Board’s standard condition is to require the applicant to obtain a zoning permit within six (6) months from approval of the subdivision application, with the option for a 12-month extension and a further twelve months from the date of Zoning Permit issuance to break ground on this project. 14. Staff recommends the Board discuss the feasibility of this standard timeline with the applicant and further discuss the possibility of an extended timeline for Zoning Permit approval if the Board and applicant feel that may be necessary, bearing in mind that an extended timeline will trigger compliance with the additional more stringent requirements of the housing preservation standards. RECOMMENDATION Staff recommends the Board work with the applicant to address the issues identified herein. Respectfully submitted, ___________________________ Marty Gillies, Development Review Planner I #SD-23-11 F. Replacement Dwelling Unit Requirement In addition to the foregoing, all replacement dwelling units built pursuant to this Section must meet the following requirements: (1) Each replacement dwelling unit shall have at least the same number of bedrooms as the dwelling unit being replaced; (2) Each replacement dwelling unit must be located within the City of South Burlington; (3) Each replacement dwelling unit must receive a Certificate of Occupancy within eighteen (18) months of the date on which the zoning permit referenced in Sub-section D above is approved; (4) Each rental replacement dwelling unit(s) must be maintained either as a Group Home or as a leased “Affordable Housing” unit, as that term is defined in Article 2 of these Regulations to prospective occupants who are income eligible at the time they first lease the unit, for a period of not less than twenty (20) years from the date of first occupancy. (5) Each non-rental replacement dwelling unit(s) must be offered for sale either: (a) At or below the fair market value of the dwelling unit that was removed, demolished, or converted to nonresidential use or nonuse, as determined either (i) by an appraisal provided by the applicant, or (ii) by the City’s latest assessed value of the premises including the dwelling unit that was removed, demolished, or converted to nonresidential use or to nonuse; or (b) As an “Affordable Housing” unit, as that term is defined in Article 2 of these Regulations, to prospective purchaser/occupants who are income eligible at the time they purchase the unit. Any such unit shall be subject to a covenant restricting the sale of the dwelling unit for a twenty (20) year period to an owner/occupant who qualifies by income. (6) Income eligibility for replacement units described in this subsection shall be determined based on income guidelines, as adjusted for household size, published annually by the U.S. Department of Housing and Urban Development (HUD) for the Burlington-South Burlington Metropolitan Statistical Area (MSA), or on program-based income eligibility requirements established by a partnering housing organization. The income eligibility shall be determined using the most recent income guidelines available at the time a unit is available for occupancy. If the applicant is not able to qualify for an exemption from these requirements under sub-section C above, the replacement units constructed must meet all criteria of this sub-section F. G. Performance Guaranty/Letter of Credit When an applicant proposes to construct a new replacement dwelling unit or convert a non-residential building to a replacement residential unit, the applicant must post a performance guaranty in the form of a letter of credit, or other security acceptable to the City Attorney, in the amount equivalent to the amount the applicant would have been required to contribute to the City of South Burlington’s Housing Trust Fund if the applicant had chosen that option pursuant to Sub-section E(3), above. Such a performance guaranty shall be valid for no more than two (2) years, after which the full amount due shall be provided to the City of South Burlington’s Housing Trust Fund if a replacement dwelling unit satisfying the conditions of this Section has not been granted a Certificate of Occupancy as a dwelling unit. If the applicant is not able to qualify for an exemption from these requirements under sub-section C above, the replacement units constructed must meet all criteria of this sub-section G. H. Administration #SD-23-11 I. Violations In the event of a violation of this Section, an enforcement action in accordance with Article 17 shall commence and the requirements of this Section shall apply in addition to any other remedies available to the City by law. Construction Timing & Phasing The applicant has indicated an estimated construction schedule in which construction on the house on Lot 6A may not be completed until 2025. The applicant will have six months from approval of this application to obtain a Zoning Permit, and a further twelve months from the date of Zoning Permit issuance to break ground on this project. 14. Staff recommends the Board discuss the feasibility of this standard timeline with the applicant and further discuss the possibility of an extended timeline for Zoning Permit approval if the Board and applicant feel that may be necessary. RECOMMENDATION Staff recommends the Board work with the applicant to address the issues identified herein. Respectfully submitted, ___________________________ Marty Gillies, Development Review Planner I PS W WWW WWWETC ETCETCWWEXISTING GRAVEL DRIVEWAY AND CURB CUT TO BE REMOVED ELEC. & (2) TEL. PEDESTAL 20' STORM DRAINAGE EASEMENT TO CITY OF SOUTH BURLINGTON EXISTING PUMP STATION D S S ST D G UDPUMP STATION G MAILBOXES w/ CONC. PAD W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER ELEC. TRANSFORMER (TYP.) G GG G (3) CONDUITS T T 10' SETBACKEXISTING BIKE PATHCLASS II 50' BUFFERDORSET STREETRESTRICTED BUILD AREATO SWIFT STREETTO OLD CROSS ROAD20' SETBACK30' SETBACK 20'S E W E R EA S E M E N T T O H O A 10 ' S E T B A C K 20' SETBACK 35' R . O . W . UT I L I T Y EA S E M E N T TO L O T 4 30' SETBACK 20'SEWEREASEMENTTO LOT 520' UTILITY EASEMENT 10'ELECTRICALEASEMENTTO GMPEXISTING HOUSE EXISTING BARN 20' UTILITY EASEMENT 50' CO N S E R V A T I O N ST R E A M B U F F E R 50' CO N S E R V A T I O N ST R E A M B U F F E R n/f JAM GOLF, LLC GOLF COURSE PARCEL F n/f COMMON LAND HIGHLAND RESIDENTAL PROPERTIES, LP. n/f LOT 173 HIGHLAND RESIDENTIAL PROPERTIES, LP. TO BE REMOVED TO BE REMOVED FOULSHAM HOLLOW ROADMEDALIST DRIVE HIGHLANDS DEVELOPMENT CO LLC n/f I. ISHAM ESTATE n/f J. RUSTAD & D. DISCANO n/f D. ROUILLE n/f S. DAVIS & E. BECHTEL n/f K. EVANS n/f G. BERGERON & R. POTHIER 10' SETBACK 10' SETBACK 20' SETBACK 20' SETBACK 20' SETBACK434434434 433 433 43 3 433 433 433432 432432 432 432 43 2 432 432 4324314314 3 1 431431 4314314314 3 1 431 430 430 430430430 43 0 430 43043043042942 9 429 42 9 429429429429429429 429429429 428 42 8 428428428 428428428428428 428 428427 427 427427427 427 427 427 427427427 427 426 426426 426 426426426 426 42642 5 4 2 5 425 425425 425424424424424424 42342342342 3 423 423422422 422422422422422 421421 421421421421421421421420420420420420420420420420419419419 41941941941941941841841 8 418 418418418 418 418417417417417417417 417416416 4164164164164164164154154154154154154154154144144 1 4 414 414414414 4144134134 1 3 41341 3 413413 413412412412412 412412412412412 411411411 4 1 1411411411411410410 410410410 410 410409409409409 409 409 4094094084 0 8 408408408 4084084074074 0 7 407407 407407 406 406406 4 0 6406406 405 405405405 405 405405404 404404 4044 0 4 404 4 0 3 40 3 4034034034 0 2 40 2 4024024014 0 1 4014004 0 0400399399398 10" OAK MAILBOX MAILBOXM A I L B O X MAILBOX C.O. C.O. SID E W A L K SIDEW AL K SIDEWALK SIDEWALK60' R.O.W.LOT 1 0.44 AC. R.O.W. 0.86 AC. LOT 2 0.80 AC. LOT 3 0.77 AC. LOT 4 0.81 AC. LOT 5 0.33 AC.250' FROM ℄ OF DORSET STREET R.O.W.LOT 6 1.29 AC. 207'±340'±67'±109'±64'±111'±4'±129'±20' SETBACK424422EXISTING TREES TO BE REMOVED (TYP.) REMOVE UNDERBRUSH AND SECONDARY GROWTH EXISTING RECESSED CURB REMOVE SHRUBS EXISTING TREES TO BE REMOVED (TYP.) (2) 12" CEDAR 8" ELM (5) 8" BLUE SPRUCE 8" BALSAM FIR 10" BALSAM FIR 10" BALSAM FIR 6" RED MAPLE 6" SILVER MAPLE 8" BLUE SPRUCE (5) 10" NORWAY SPRUCE 8" NORWAY MAPLE 18" NORTHERN RED OAK 24" BLACK LOCUST 10" BLUE SPRUCEJAPANESE YEW10" CHESTNUT OAK 10" BLACK OAK 12" WHITE SPRUCE 3-BOL 8" WHITE CEDAR 14" AMERICAN ELM 4" NORWAY SPRUCE 12" SILVER MAPLE (19) 6"-8" NORTHERN WHITE CEDAR 8" NORWAY MAPLE 8" BOX ELDER 16" NORWAY MAPLE JAPANESE YEWHEDGEROW(10'-15' HEIGHT) COMMON LILAC COMMON LILAC JAPANESE YEW 8" YELLOW BUCKEYE 8" BLACK MAPLE 6" SILVER MAPLE 18" SHAGBARK HICKORY DSM DSM MAB 1" = 30' 22117 C1.0 01/05/2023 LOCATION MAP 1" = 2000' 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 EXISTING CONDITIONS and PROPOSED DEMOLITIONS SITE PLAN PROJECT LOCATION A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 NOTES 1.UTILITIES SHOWN DO NOT PURPORT TO CONSTITUTE OR REPRESENT ALL UTILITIES LOCATED UPON OR ADJACENT TO THE SURVEYED PREMISES. EXISTING UTILITY LOCATIONS ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL FIELD VERIFY ALL UTILITY CONFLICTS. ALL DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER. THE CONTRACTOR SHALL CONTACT DIG SAFE (888-344-7233) PRIOR TO ANY CONSTRUCTION. 2.PROPERTY LINE INFORMATION IS BASED ON A PLAN ENTITLED "PAUL F. HEALD 6 LOT SUBDIVISION DORSET STREET" PREPARED BY CIVIL ENGINEERING ASSOCIATES, INC. DATED AUGUST 2001, LAST REVISED 12-4-01. THIS PLAN IS NOT A BOUNDARY SURVEY AND IS NOT INTENDED TO BE USED AS ONE. 3.PROPERTY LINE BEARINGS ARE BASED ON MAGNETIC NORTH NOT TRUE NORTH. 4.CONTOUR INFORMATION IS BASED UPON LIDAR DATA FROM 2014. HORIZONTAL AND VERTICAL DATUM BASED ON VCS NAD 83 AND NAVD 88. LEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COMETC 2 LOT SUBDIVISION LOT 6 EXISTING DECIDUOUS TREE EXISTING CONIFEROUS TREE P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 5/5/2023 8:32:54 AMMAN MADE STEEP SLOPES PS W W W W W W WW W W W WWWWGGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETCETCETCWW W W W W WWG G G G GG G G GGGSSSS SSSSFM FM FMFMFMFMFM FM FMFMFMFMFMFMFMSSSSSSSSSSSSSSSSSSSSWWPROPOSED 12' WIDE PAVED DRIVEWAY OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEELEC. & (2) TEL. PEDESTAL 20' STORM DRAINAGE EASEMENT TO CITY OF SOUTH BURLINGTON WWWWWWWWWWWWWWS SFMFMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM ST ST ST D ET C ETC G G G G UDPUMP STATION G G MAILBOXES w/ CONC. PAD W W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER G G GG(3) CONDUITS ETCG EXISTING MAN MADE SLOPE. TIE PROPOSED CONTOURS TO AND THROUGH THIS SLOPE, AS SHOWN EXTEND SIDEWALK TO PROPOSED DRIVE STONE WALL, STEPPED 2' X 4' BOULDERS (MAX 8' HIGH) S PROPOSED PROPERTY LINE T EXISTING BIKE PATHDORSET STREETTO SWIFT STREET20 'SE W E R EA S E M E N T T O H O A 35' R . O . W . UT I L I T Y EA S E M E N T T O L O T 4 20' UTILITY EASEMENT 10'ELECTRICALEASEMENTTO GMP20' UTILITY EASEMENT C.O. PROPOSED HOUSE FFE=436.0±FOULSHAM HOLLOW ROAD4" WATER MAIN20" WATER MAINEX. 4 " SEWER S ERV ICE 8" CL52 D.I.EX. 34" WATER SERVICE6" PE433.5 + 4 3 0 4 2 8 4 2 6 430 428 426 424 4 2 2 42 0420 42 0422424426 42241 8 4164144 1 6 416 418 42 0 422424418418 434434434434 433 433 43 3 433 433 433432 432 432 432 43 2 432 43 2431431 43 1 431431 4314 3 1 430430 430 43043043042 9 429429429428 428428428427427 427 42742642442342242142142142142042042041941941841 8 418 4184174174164164164154154154154144 1 4 414413 4 1 3 413412 412412412 411411411410410410409 409409409 4 0 8 40840840740740740 6406406 8" MAPLE 4" MAPLE 8" OAK 8" OAK 8" OAK8" O A K 10" MAPLE 12" OAK 12" MAPLE 12" SPRUCE 12" MAPLE 12" OAK 4" MAPLE 4" MAPLE MAILBOX MAILBOXM A I L B O X MAILBOX 10" OAK SID E W A L K SIDE W AL K SIDEWALK SIDEWALK60' R.O.W.FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC 434 433432430428426431 432 433 434 428431422424426 428 430 432 GARAGE FFE=434.0± PROPOSED GARAGE FFE=434.0± + 433.5 433.5 + 431 432433 434 434 WCOVEREDPORCHSCREEN PORCH POTENTIAL PATIO 427 4 2 6 426427COVERED PORCH POTENTIAL COVERED PORCH EXISTING RECESSED CURB 433.5 + SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT 1" = 20'C2.0 PROPOSED CONDITIONS PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATIONLEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS 01/05/2023 2 LOT SUBDIVISION LOT 6 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 LOT SIZE CATEGORY EXISTING SETBACK FRONT YARD - FOULSHAM HOLLOW FRONT YARD - DORSET STREET 20' ZONING REGULATIONS 20' 23' 20' 9,500 S.F. (MIN.) COVERAGE BUILDING COVERAGE 20%6% BUILDING HEIGHT 28' (PITCHED) SIDE YARD 10'117' 56,167 S.F. ± ZONING DISTRICT:SEQ-NEIGHBORHOOD RESIDENTIAL LOT COVERAGE 40%10% 65' 62' 13% 24' 21% 29,947 S.F. ± PROPOSED LOT 6A 49' 21' 9% 72' 24% 26,219 S.F. ± PROPOSED LOT 6B 28' 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 5/3/2023 10:49:03 AM, DWG To PDF.pc3 PS W W W W W W WW W W W WWWWGGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETCETCETCWW W W W W WWG G G G GG G G GGGSSSS SSSSFM FM FMFMFMFMFM FM FMFMFMFMFMFMFMSSSSSSSSSSSSSSSSSSSSWWPROPOSED 12' WIDE PAVED DRIVEWAY OE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEELEC. & (2) TEL. PEDESTAL 20' STORM DRAINAGE EASEMENT TO CITY OF SOUTH BURLINGTON WWWWWWWWWWWWWWS SFMFMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM ST ST ST D ET C ETC G G G G UDPUMP STATION G G MAILBOXES w/ CONC. PAD W W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER G G GG(3) CONDUITS ETCG EXISTING MAN MADE SLOPE. TIE PROPOSED CONTOURS TO AND THROUGH THIS SLOPE, AS SHOWN EXTEND SIDEWALK TO PROPOSED DRIVE STONE WALL, STEPPED 2' X 4' BOULDERS (MAX 8' HIGH) S PROPOSED PROPERTY LINE T EXISTING BIKE PATHDORSET STREETTO SWIFT STREET20 'SE W E R EA S E M E N T T O H O A 35' R . O . W . UT I L I T Y EA S E M E N T T O L O T 4 20' UTILITY EASEMENT 10'ELECTRICALEASEMENTTO GMP20' UTILITY EASEMENT C.O. PROPOSED HOUSE FFE=436.0±FOULSHAM HOLLOW ROAD4" WATER MAIN20" WATER MAINEX. 4 " SEWER S ERV ICE 8" CL52 D.I.EX. 34" WATER SERVICE6" PE433.5 + 4 3 0 4 2 8 4 2 6 430 428 426 424 4 2 2 42 0420 42 0422424426 42241 8 4164144 1 6 416 418 42 0 422424418418 434434434434 433 433 43 3 433 433 433432 432 432 432 43 2 432 43 2431431 43 1 431431 4314 3 1 430430 430 43043043042 9 429429429428 428428428427427 427 42742642442342242142142142142042042041941941841 8 418 4184174174164164164154154154154144 1 4 414413 4 1 3 413412 412412412 411411411410410410409 409409409 4 0 8 40840840740740740 6406406 8" MAPLE 4" MAPLE 8" OAK 8" OAK 8" OAK8" O A K 10" MAPLE 12" OAK 12" MAPLE 12" SPRUCE 12" MAPLE 12" OAK 4" MAPLE 4" MAPLE MAILBOX MAILBOXM A I L B O X MAILBOX 10" OAK SID E W A L K SIDE W AL K SIDEWALK SIDEWALK60' R.O.W.FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC 434 433432430428426431 432 433 434 428431422424426 428 430 432 GARAGE FFE=434.0± PROPOSED GARAGE FFE=434.0± + 433.5 433.5 + 431 432433 434 434 WCOVEREDPORCHSCREEN PORCH POTENTIAL PATIO 427 4 2 6 426427COVERED PORCH POTENTIAL COVERED PORCH EXISTING RECESSED CURB 433.5 + SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT 1" = 20'C2.0 PROPOSED CONDITIONS PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATIONLEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS 01/05/2023 2 LOT SUBDIVISION LOT 6 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 LOT SIZE CATEGORY EXISTING SETBACK FRONT YARD - FOULSHAM HOLLOW FRONT YARD - DORSET STREET 20' ZONING REGULATIONS 20' 23' 20' 9,500 S.F. (MIN.) COVERAGE BUILDING COVERAGE 20%6% BUILDING HEIGHT 28' (PITCHED) SIDE YARD 10'117' 56,167 S.F. ± ZONING DISTRICT:SEQ-NEIGHBORHOOD RESIDENTIAL LOT COVERAGE 40%10% 65' 62' 13% 24' 21% 29,947 S.F. ± PROPOSED LOT 6A 49' 21' 9% 72' 24% 26,219 S.F. ± PROPOSED LOT 6B 28' 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 5/3/2023 9:13:53 AM, DWG To PDF.pc3 PS W W W W W W WW W W W WWWWGGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETCETCETCWW W W W W WWG G G G GG G G GGGSSSS SSSSFM FM FM FMFMFMFM FM FMFMFMFMFMFMFMSSSSSSSSSSSSSSSSSSSSWWOE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOENEW UTILITY POLE AND SERVICE DROP ELEC. & (2) TEL. PEDESTAL 20' STORM DRAINAGE EASEMENT TO CITY OF SOUTH BURLINGTON WWWWWWWWWWWWWW10' MIN. S SFMFMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM ST ST ST D ET C ETC G G INV=426.0 G G UDPUMP STATION G G MAILBOXES w/ CONC. PAD W W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER G G GG G (3) CONDUITS ETCUNDERGROUND POWER AND COMMUNICATION (TYP) G NEW GAS SERVICE NEW GAS SERVICE CUT AND REROUTE EXISTING WATER SERVICE EXTEND SIDEWALK TO PROPOSED DRIVE CUT AND REROUTE EXISTING 2" TYPE K WATER SERVICE WITH A NEW 1" TYPE K WATER SERVICE TO THE NEW HOUSE S INV=426.0 MAINTAIN 18" MIN. VERTICAL SEPARATION BETWEEN WATER AND SEWER SERVICES INV=419.0± (ASSUMED) PROPOSED PROPERTY LINE T EXISTING BIKE PATHDORSET STREETTO SWIFT STREET20 'SE W E R EA S E M E N T T O H O A 35' R . O . W . UT I L I T Y EA S E M E N T T O L O T 4 20' UTILITY EASEMENT 10'ELECTRICALEASEMENTTO GMP20' UTILITY EASEMENT C.O. PROPOSED HOUSE FFE=436.0±FOULSHAM HOLLOW ROAD4" WATER MAIN20" WATER MAINEX. 4 " SEWER S ERV ICE 8" CL52 D.I.EX. 34" WATER SERVICE1" TYPE KWATER SERVICE4" SDR 35 PVCSEWER SERVICEc.o.6" PE8" MAPLE 4" MAPLE 8" OAK 8" OAK 8" OAK8" O A K 10" MAPLE 12" OAK 12" MAPLE 12" SPRUCE 12" MAPLE 12" OAK 4" MAPLE 4" MAPLE MAILBOX MAILBOXM A I L B O X MAILBOX 10" OAK SID E W A L K SIDE W AL K SIDEWALK SIDEWALK60' R.O.W.FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC GARAGE FFE=434.0± PROPOSED GARAGE FFE=434.0±W4" SDR 35 PVC SEWER SERVICE c.o.COVEREDPORCHSCREEN PORCH POTENTIAL PATIO COVERED PORCH POTENTIAL COVERED PORCH EXISTING RECESSED CURB REROUTE AND EXTEND THE EXISTING 4" SDR35 PVC SEWER SERVICE MAINTAIN MIN. SLOPE OF 14" PER FOOT 1" TYPE K WATER SERVICE SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT SAW CUT, REMOVE AND REPLACE EXISTING PAVEMENT 1" = 20'C2.1 PROPOSED UTILITY SITE PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATION 01/05/2023 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 2 LOT SUBDIVISION LOT 6 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 LEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 5/3/2023 9:13:23 AM, DWG To PDF.pc3 PS S S D DORSET STREETFOULSHAM HOLLOW ROAD6" PE8" MAPLE 4" MAPLE 8" OAK 8" OAK 8" OAK8" O A K 10" MAPLE 12" MAPLE 12" SPRUCE 12" MAPLE 12" OAK 4" MAPLE 4" MAPLE 10" OAK8" ELM 8" BALSAM FIR 10" BALSAM FIR 10" BALSAM FIR 6" RED MAPLE 6" SILVER MAPLE 8" BLUE SPRUCE (5) 10" NORWAY SPRUCE 8" NORWAY MAPLE 10" BLUE SPRUCE 10" CHESTNUT OAK 10" BLACK OAK 12" SILVER MAPLE (19) 6"-8" NORTHERN WHITE CEDAR 8" NORWAY MAPLE 8" BOX ELDER 16" NORWAY MAPLE JAPANESE YEWHEDGEROW(10'-15' HEIGHT) COMMON LILAC COMMON LILAC JAPANESE YEW 8" YELLOW BUCKEYE 8" BLACK MAPLE 6" SILVER MAPLE 18" SHAGBARK HICKORY 1" = 20'C1.1 PROPOSED LANDSCAPE PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATIONLEGEND FM OE G ST S W EXISTING CONTOUR EXISTING CURB EXISTING FENCE EXISTING GRAVEL EXISTING PAVEMENT EXISTING GUARD RAIL WETLANDS WETLANDS BUFFER EXISTING OVERHEAD ELECTRIC EXISTING FORCEMAIN EXISTING GAS EXISTING STORM EXISTING GRAVITY SEWER EXISTING WATER STREAM EXISTING SEWER MANHOLE EXISTING STORM MANHOLE EXISTING CATCH BASIN EXISTING HYDRANT EXISTING SHUT OFF EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING SIGN SETBACK LINE PROPERTY LINE S D EXISTING UNDERGROUND ELEC.-TEL.-COM ETC G S W UE PROPOSED CONTOUR100 PROPOSED PAVEMENT PROPOSED ELECTRIC PROPOSED GAS PROPOSED GRAVITY SEWER PROPOSED WATER PROPOSED EDGE OF BRUSH/WOODS 01/05/2023 2 LOT SUBDIVISION LOT 6 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 PROPOSED SETBACK LINE PROPOSED PROPERTY LINE PROPOSED SHUT OFF P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 5/5/2023 8:32:36 AM PS W W W W W W WW W W W WWWWGGGGGGGGGGGGGGETC ETC ETC ETC ETCETCETCETCETCETC ETC ETC ETCETCETCWW W W W W WWG G G G GG G G GGGSSSS SSSSFM FM FMFMFMFMFM FM FMFMFMFMFMFMFMSSSSSSSSSSSSSSSSSSSSWWOE OE OE OEOEOEOEOEOEOEOEOEOEOEOEOEELEC. & (2) TEL. PEDESTAL WWWWWWWWWWWWWWS SFMFMFMFMFMFMFM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFM ST ST ST D ET C ETC G G INSTALL CONSTRUCTION LIMITS TAPE (TYP.) TEMPORARY STABILIZED CONSTRUCTION ENTRANCE INSTALL 4" TOPSOIL, FERTILIZE, LAWN SEED AND INSTALL ROLLED EROSION CONTROL MATTING (TYP.) INSTALL SILT FENCING (TYP.) DOWN GRADIENT OF ALL DISTURBED AREAS G G UDPUMP STATION G G MAILBOXES w/ CONC. PAD W W W (2) TEL. PEDESTAL ELEC. METER ELEC. & TEL. PEDESTAL ELEC. METER G G GG(3) CONDUITS ETCG EXISTING MAN MADE SLOPE. TIE PROPOSED CONTOURS TO AND THROUGH THIS SLOPE, AS SHOWN S T EXISTING BIKE PATHDORSET STREETTO SWIFT STREETC.O. PROPOSED HOUSE FFE=436.0±FOULSHAM HOLLOW ROAD4" WATER MAIN20" WATER MAINEX. 4 " SEWER S ERV ICE 8" CL52 D.I.EX. 34" WATER SERVICE6" PETEMPORARY TOPSOIL STOCKPILE 4 3 0 4 2 8 4 2 6 430 428 426 424 4 2 2 42 0420 42 0422424426 42241 8 4164144 1 6 416 418 42 0 422424418418 434434434434 433 433 43 3 433 433 433432 432 432 432 43 2 432 43 2431431 43 1 431431 4314 3 1 430430 430 43043043042 9 429429429428 428428428427427 427 42742642442342242142142142142042042041941941841 8 418 4184174174164164164154154154154144 1 4 414413 4 1 3 413412 412412412 411411411410410410409 409409409 4 0 8 40840840740740740 6406406 MAILBOX MAILBOXM A I L B O X MAILBOX C.O. C.O. SID E W A L K SIDE W AL K SIDEWALK SIDEWALK424422FUTURE HOUSE POSSIBLE LOCATION FFE= 436.0± 207'±129'±4'±74'± 72'± 83'±133'±206'±67'±108'±34'±36'±LOT 6A 0.69± AC LOT 6B 0.60± AC 434 433432430428426431 432 433 434 428431422424426 428 430 432 GARAGE FFE=434.0± PROPOSED GARAGE FFE=434.0± 431 432433 434 434 WCOVEREDPORCHSCREEN PORCH PATIO 427 4 2 6 426427COVERED PORCH COVERED PORCH TEMPORARY TOPSOIL STOCKPILE 1" = 20'C3.0 EPSC SITE PLAN A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com 22117 DSM DSM MAB LOCATION MAP 1" = 2000' PROJECT LOCATION LEGEND NOTES: 1.ALL EROSION AND SEDIMENT CONTROL DEVICES MUST BE INSTALLED AND STABILIZED BEFORE THE START OF CONSTRUCTION. 2.LOAM, SEED AND MULCH ALL DISTURBED AREAS (TYP.) 3.INSTALL TEMPORARY STABILIZATION OF DISTURBED SOILS THROUGH THE INSTALLATION OF 1" OF HAY MULCH NO MORE THAN 7 DAYS AFTER WORK HAS CEASED IN A PARTICULAR AREA. 4.SLOPES >3:1 SHALL RECEIVE EROSION CONTROL MATTING. 5.MAXIMUM AMOUNT OF DISTURBED SOILS TO BE LIMITED TO NO MORE THAN 2 ACRES. 6.SILT FENCE CONTRIBUTORY AREA TO BE LIMITED TO 14 ACRE / 100 L.F. 7.SOIL INFORMATION PROVIDED BY NATURAL RESOURCES CONSERVATION SERVICES WEB SOIL SURVEY 09/13/2021 CONSTRUCTION LIMITS TAPE EROSION CONTROL MATTING SILT FENCE TREE PROTECTION INLET PROTECTION 01/05/2023 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 2 LOT SUBDIVISION LOT 6 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Site.dwg, 5/2/2023 2:47:39 PM, DWG To PDF.pc3 AS SHOWN 22117 C3.1 A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com DSM DSM MAB EPSC NOTES AND DETAILS E-001 EC SheetN.T.S. CONSTRUCTION FENCE DETAIL REVISED 08/01/2014E-002E-002 Constr FenceWOOD POST 30"18"EXISTING GRADE NATIVE MATERIAL PLASTIC ORANGE CONSTRUCTION FENCE REVISED 08/01/2014E-004E-004 Constr. Ent20' (6m) RROADWAYAA STABILIZED CONSTRUCTION ENTRANCE N.T.S.12'. MIN.50' MIN. SECTION A-A DIVERSION RIDGE REQUIRED WHERE GRADE EXCEEDS 2% ROADWAY 2% OR GREATER SPILLWAY FILTER FABRIC SANDBAGS OR CONTINUOUS BERM OF EQUIVALENT HEIGHT DIVERSION RIDGE SUPPLY WATER TO WASH WHEELS IF NECESSARY 2"-3" (50-75mm) COURSE AGGREGATE MIN. 8" (150mm) THICK PLAN VIEW NOTES: 1.THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHT-OF-WAYS. THIS MAY REQUIRE TOP DRESSING, REPAIR AND/OR CLEAN OUT OF ANY MEASURES USED TO TRAP SEDIMENT. 2.WHEN NECESSARY, WHEELS SHALL BE CLEANED PRIOR TO ENTRANCE ONTO PUBLIC RIGHT-OF-WAY. 3.WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE THAT DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN. NOTE: USE SANDBAGS OR OTHER APPROVED METHODS TO CHANNELIZE RUNOFF TO BASIN AS REQUIRED REVISED 08/01/2014E-003E-003 Silt FenceN.T.S. SILT FENCE DETAIL NOTES: 1. INSTALL MIRAFI ENVIROFENCE, OR APPROVED EQUAL OR AS DETAILED HEREIN. 2. INSTALL SILT FENCES AT TOES OF ALL UNPROTECTED SLOPES AND AS PARALLEL TO CONTOURS AS POSSIBLE. THIS INCLUDES ALL FILLED OR UNPROTECTED SLOPES CREATED DURING CONSTRUCTION, NOT NECESSARILY REFLECTED ON THE FINAL PLANS. CURVE THE ENDS OF THE FENCE UP INTO THE SLOPE. REMOVE SEDIMENT WHEN ACCUMULATED TO HALF THE HEIGHT OF THE FENCE. SILT FENCES ARE TO BE MAINTAINED UNTIL SLOPES ARE STABILIZED. 3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER, THEY SHALL BE OVERLAPPED BY 6", FOLDED AND STAPLED. 10' 10' 2.5' METAL POST 4 x 4 WOOD POST SPACING 212 X 212 WOOD 36" MIN.12" MIN.POST 2"8"FILTER FABRIC TO BE MIRAFI 100X OR APPROVED EQUAL FILTER FABRIC TO BE CLIPPED, BACKFILLED AND TAMPED 8" BELOW GRADE STEEL OR WOOD STAKES (SEE CHART AT RIGHT) REVISED 08/01/2014E-005E-005 StockpileTEMPORARY STOCKPILE DETAIL N.T.S. TEMPORARY SEEDING & MULCH OR NETTING SILT FENCE OR HAY BALES INSTALLED ON DOWN GRADIENT SIDE REVISED 08/01/2014E-007E-007 Infilt SectSILT FENCE CONSTRUCTION DETAIL N.T.S. 2. ATTACH SILT FENCE AND EXTEND IT TO THE TRENCH. 3. STAPLE THE SILT FENCING TO THE END POSTS. BACKFILL TRENCH. 1. SET POSTS AND EXCAVATE A 4"X8" TRENCH, SET POST DOWNSLOPE. ANGLE 10° UPSLOPE FOR STABILITY AND SELF CLEANING POSTS SILT FENCE 1 0 0 °12"MIN.8"COMPACTED BACKFILL Introduction This project is subject to the terms and conditions of the authorization from the State of Vermont to discharge construction related storm water runoff. Coverage under the State Construction General Permit 3-9020 is required for any construction activity that disturbs 1 or more acres of land, or is part of a larger development plan that will disturb 1 or more acres. This project has been deemed to qualify as a Low Risk Site which is subject to the erosion prevention and sediment control (EPSC) standards set for in the State of Vermont's Low Risk Site Handbook for Erosion Prevention and Sediment Control The following narrative and implementation requirements represent the minimum standard for which this site is required to be maintained as regulated by the State of Vermont. Any best management practices (BMP's) depicted on the project's EPSC Site plan which go beyond the Handbook requirements are considered to be integral to the management of the site and represent components of the municipal EPSC approval for the project which shall be implemented. The EPSC plan depicts one snap shot in time of the site. All construction sites are fluid in their day to day exposures and risks as it relates to minimizing sediment loss from the site. It is the responsibility of the Contractor to implement the necessary BMP's to comply with the Low Risk Handbook standards outlined on this sheet based on the interim site disturbance conditions which may or may not be shown on the EPSC Site Plan. Specific BMP's which are critical to allowing the project to be considered a Low Risk site include the items checked below: ·Limit the amount of disturbed earth to two acres or less at any one time. ·There shall be a maximum of 7 consecutive days of disturbed earth exposure in any location before temporary or final stabilization is implemented. 1.Demarcate Limits of Disturbance Purpose: Delineating the site will help to: limit the area of disturbance to only what is necessary for construction, prevent unauthorized disturbance, preserve existing vegetation, and limit erosion potential on the site. Requirement: You must physically mark the limits of construction activity using one of the methods described below. How to comply: Before initiating any earth disturbing activities, install a perimeter fence, orange barrier tape, or flagging on stakes or trees to physically demarcate the approved limits of earth disturbance. 2.Pollution Prevention Purpose: Many construction sites require storage of chemicals and materials that have detrimental effects if released into our waterways. A storage plan for these potential pollution sources as well as a spill prevention and clean up plan are required to mitigate these risks. Requirement: Design, install, implement, and maintain effective pollution prevention measures to minimize the discharge of pollutants. At a minimum, such measures must be designed, installed, implemented and maintained in accordance with the following requirements. How to comply: 1. Minimize the exposure of the following to precipitation and to stormwater: building materials, building products, construction wastes, trash, landscape materials, fertilizers, pesticides, herbicides, detergents, sanitary waste, and other materials present on the site. 2. Minimization of exposure is not required in cases where the exposure to precipitation and to stormwater will not result in a discharge of pollutants, or where exposure of a specific material or product poses little risk of stormwater contamination (such as final products and materials intended for outdoor use). 3.Limit Concurrent Earth Disturbance Purpose: Limit the amount of soil exposed at one time to reduce the potential erosion on the construction site. Requirement: The maximum area of concurrent earth disturbance is specified on the site's written authorization to discharge. Earth disturbance at any one time cannot exceed the maximum concurrent disturbance identified in the authorization. Areas that are at final stabilization ornthat have been temporarily stabilized in accordance with Section 4 of this handbook, are not counted toward the maximum concurrent disturbance area. How to comply: Plan ahead and phase the construction activities to ensure that no more than the permitted maximum concurrent acreage is disturbed and unstabilized at one time. Be sure to properly stabilize exposed soil using one of the methods introduced in Section 4 of this handbook before beginning work in a new section of the site. 4.Site Stabilization Purpose: Seeding and mulching, applying erosion control matting, and hydroseeding are all methods to temporarily stabilize exposed soil and prevent soil erosion prior to vegetative growth. Mulches and matting protect the soil surface while grass is establishing. Areas of earth disturbance may also be stabilized with stone, such as rip-rap or gravel, or other impervious surfaces such as pavement and concrete. Requirements for Temporary Stabilization: All areas of earth disturbance must have temporary or final stabilization within 14 days of initial disturbance, as stated in the project authorization. After this time, disturbed areas must be temporarily stabilized or permanently stabilized in advance of any runoff producing event. A runoff producing event is an event that produces runoff from the construction site. The following exception applies: Temporary stabilization is not required if the work is occurring in a self-contained excavation (i.e. no outlet) with a depth of 2 feet or greater (e.g. house foundation excavation, utility trenches), provided any dewatering, if necessary, is conducted in accordance with Part 13. How to comply: As required by the authorization, temporary stabilization for areas of earth disturbance shall be completed utilizing one or more of the methods below: Straw Mulch Mulching Rates April 16 - Oct. 14 -- Straw: 1 inch deep (1-2 bales/1,000 s.f.) Oct. 15 - April 15 -- Straw: 2 inch deep (2-4 bales/1,000 s.f.) *seed may also be incorporated Wood Chip Mulch or Stump Grindings Cover entire area with 2-7 inches or more of wood chip mulch or stump grindings. Hydroseed As per manufacturer's instructions. Must include mulch component. Not acceptable stabilization for winter construction period. Requirements for Dust Control: Construction roads, access points, and other disturbed areas subject to surface dust movement and dust blowing during dry periods where off-site damage may occur if dust is not controlled shall be sprayed with water to prevent dust mobilization. Chemical applications, including the use of chloride, shall not be applied without written approval from the VT DEC. Requirements for Final Stabilization: All areas of disturbance must have permanent stabilization within 48 hours of reaching final grade. Bring the site or sections of the site to final grade as soon as possible after construction is completed. This will reduce the need for additional sediment and erosion control measures and will reduce the total disturbed area. Prepare bare soil for seeding by grading the top 4 to 6 inches of soil and removing any large rocks or debris, and apply seed per suppliers specifications. 5.Stabilized Construction Access Purpose: A stabilized construction access helps remove mud and sediment from vehicles and equipment to prevent tracking onto streets. Requirements: If there will be any vehicle or equipment traffic off of the construction site, you must install a stabilized construction access at the start of construction. How to install: Rock Size: Use a mix of 1 to 4 inch stone Depth: 8 inches minimum Width: 12 feet minimum, flared at road for vehicle turning Length: 40 feet minimum (or length of driveway for residential projects, if shorter) Geotextile: Place filter cloth under entire stone bed Maintenance: Redress with clean stone or scarify to open voids as required to keep sediment from tracking onto the street. ·Where sediment has been tracked-out from your site onto paved roads, sidewalks, or other paved areas outside of your site, remove the deposited sediment by the end of the same business day in which the track-out occurs or by the end of the next business day if track-out occurs on a non-business day. ·Remove the track-out by sweeping, shoveling, or vacuuming these surfaces, or by using other similarly effective means of sediment removal. ·You are prohibited from hosing or sweeping tracked out sediment into any stormwater conveyance, storm drain inlet, or water of the state. 6.Divert Upland Runoff Purpose: Diversion berms intercept stormwater runoff contributing from above the construction site and direct it around the disturbed area. This prevents offsite runoff from entering the construction site, thus reducing the potential for erosion and reducing the drainage area contributing to the site. Requirements: If stormwater runoff contributes to the construction site from upslope areas and the site meets the following two conditions, you are required to first install a diversion berm and stabilized swale before disturbing any additional soil. 1. One or more acres of soil will be disturbed at any one time. 2. Average slope of the disturbed area is 20% or steeper.* Diversion Berm installation: 1. Construct berm to the minimum specification above. 2. Compact the berm with a shovel or earth-moving equipment. 3. Seed and mulch berm or cover with erosion control matting immediately after installation. 4. Stabilize the flow channel with seed and mulch or erosion control matting. Line the channel with 4 inch stone if the channel slope is greater than 20%. 5. Ensure the berm drains to an outlet stabilized with ripra p. Ensure that there is no erosion at the outlet. 6. The diversion berm shall remain in place until the disturbed areas are completely stabilized. 7.Install Perimeter Controls Purpose: Silt Fence and Erosion Control Berms intercept runoff and allow suspended sediment to settle or filter out. Filter Socks and Straw Wattles also filter construction runoff and are acceptable for use in specific situations. Silt Fence, Erosion Control Berms, Filter Socks and Straw Wattles are all acceptable perimeter controls based on site specific conditions. Permittee(s) must ensure the right practice is selected for erosion prevention and sediment control. Requirements: Perimeter controls must be installed: ·On the downhill side of the construction activities ·Between any ditch, swale, storm drain, or surface water and the disturbed soil ·Perimeter controls not labeled as biodegradable shall be removed once the drainage area has reached final stabilization How to Comply: Select and install a perimeter control from the following options: Silt Fence, Erosion Control Berms, Filter Socks, or Straw Wattles. Where to place: ·Place perimeter controls on the downhill side of disturbed soil. If space is available, place perimeter control 10 ft from the bottom of the slope, otherwise place along the contour at the bottom of the slope. ·Ensure the perimeter control catches all runoff from distrubed soil. ·Maximum drainage area is¼ acre for 100 feet of silt fence and erosion control berm. ·Install perimeter controls across the slope (not up and down slope) ·Install multiplerows of perimeter control on long slopes to intercept flow. ·Do not install perimeter controls across ditches, channels, or streams. ·Maximum slope length (in feet) above a filter sock or straw wattle Silt Fence A temporary barrier of geotextile fabric installed on the contours across a project site to intercept sediment laden runoff from small drainage areas of disturbed soil. Silt Fence Installation: ·Dig a trench 6 inches deep across the slope ·Unroll silt fence along the trench ·Ensure stakes are on the downhill side of the fence ·Join fencing by rolling the end stakes together ·Drive stakes in against downhill side of trench ·Drive stakes until 16 inches of fabric is in trench ·Push fabric into trench; spread along bottom ·Fill trench with soil and pack down ·Gravel can be used to create ground contact with filter fabric when bedrock, ledge, or nearby tree roots do not allow for trenching. (A secondary perimeter control can be effective in these locations as well.) Silt Fence Maintenance: Remove accumulated sediment before it is halfway up the fence. Ensure that silt fence is trenched in ground and there are no gaps. Replace any silt fence that is torn, ripped, or otherwise damaged that 8.Storm Inlet Protection Purpose: Existing or new storm inlets on construction sites constitute a site perimeter and must be protected from sediment laden runoff. The practices below allow stormwater to settle and filter through the practice and not bypass the in let entirely. Requirements: Stormwater inlets shall be 4 inches above grade or an acceptable inlet control/protection should be installed. Inlet Protection Installation: Proprietary Inlet Protection: Shall provide for storage and removal of sediment and be sized appropriately for the drainage area, while allowing stormwater to filter through. These may be used if installed and maintained in accordance with the manufacturer's specifications. Stone and Block Inlet Protection: Concrete blocks placed around an inlet with a circle of filtering stone sloped against the blocks. Filter Fabric and Stone Inlet Protection: Vertical filter fabric installed around drop inlet with stone around fabric for stormwater filtering and creating ground contact with filter fabric. Alternatively, fabric may be buried below ground. 9.Water Bars Purpose: Some sites may benefit from the use of water bars on the construction site. When installed these may capture and redirect runoff to a stable low gradient location. Water bars limit the erosive velocity of water by diverting surface runoff at pre-designed intervals. Requirements: These can be constructed per the following detail, with side slopes no steeper than 4:1 where vehicles cross with a minimum design height of 12 inches, measured from channel bottom to ridge top. Water Bar installation: Water bars should have stable outlets, either natural or constructed. The spacing should follow Table 1: 10.Slow Down Channelized Runoff Purpose: Stone check dams reduce erosion in drainage channels by slowing down the stormwater flow. Requirements: If there is a concentrated flow(e.g. in a ditch or channel) of stormwater on your site, then you are required to install stone check dams. Hay bales and silt fence must not be used as check dams. Check Dam installation: Height: No greater than 2 feet. Center of dam should be 9 inches lower than the side elevation Side slopes: 2:1 or flatter (see p.63 for slope calculation) Stone size: Use a mixture of 2 to 9 inch stone; the larger stone should act as armoring, while the smaller stone helps to filter the channelized runoff. The small stone should be placed primarily in the interior of the check dam and the large stone should be placed in an armoring layer on the outside. Width: Dams should span the width of the channel and extend up the sides of the banks Spacing: Space the dams so that the bottom (toe) of the upstream dam is at the elevation of the top (crest) of the downstream dam. This spacing is equal to the height of the check dam divided by the channel slope. Check Dam Maintenance: Correct all observed damage immediately after every ru naff event. Remove all sediment accumulated behind the check dams and dispose of in an upland location. If significant erosion is observed between check dams, the channel shall be stone lined. Rock Outlet Protection: Waterways or outlets with concentrated stormwater runoff shall be stabilized with riprap, proprietary stabilization product or permanent material. This additional stabilization is applicable in areas where the channel slope and velocity or soil type require additional stabilization. All outlets from concentrated stormwater flows will require a stabilized bed. Stone shall be sized so it is not mobilized during high flows. 11.Slope Stabilization Purpose: Surface covering designed to protect and stabilize an area prone to erosion where seeding and mulching may be inadequate, generally slopes 3:1 or greater. The erosion potential may be due solely to slope angle; however, a more gradual slope and poor soil structure can also require additional stabilization. Requirements for Temporary Stabilization: Use of one of the listed slope protection practices below on slopes 3:1 and greater or as needed on flatter slopes based on soil type. Riprap: A layer of stone designed to protect and stabilize areas subject to erosion.Rolled Erosion Control Product: A preformed protective blanket of straw or other plant residue, formed into a mat, with a supporting mesh framework on one or both sides. This mesh cannot be made of a material with welded joints. Erosion Control Matting: Install per manufacturer's instructions. 12.Winter Construction Requirements: October 15 - April 15 Purpose: 'Winter construction' as discussed here, describes the period from October 15 through April 15, when erosion prevention and sediment control is significantly more difficult. There are specific requirements for sites that conduct earth disturbance during the defined Winter Construction Period and for sites where disturbed areas have not reached final stabilization by October 15. Rains in late fall, thaws throughout the winter, and spring melt and rains can produce significant flows over frozen and saturated ground, greatly increasing the potential for erosion. A construction site can be managed to anticipate these conditions to prevent erosion and thus minimize the risk to water quality during this time period. Requirements for Winter Shutdown: For projects or areas of a site that will have completed earth disturbance activities prior to the winter construction period (October 15 through April 15), the following requirements must be adhered to: 1. For areas to be stabilized for the winter through the establishment of vegetation, seeding and mulching shall be completed no later than September 15 to ensure adequate growth and cover before the start of the winter period. 2. If seeding is not completed by September 15, additional non-vegetative protection must be used to stabilize the site for the winter period. Areas of disturbance not seeded and mulched by September 15 are required to temporarily stabilize by one of the following methods: Implement Rolled Erosion Control Products (i.e. matting) over the areas of earth disturbance. Apply a 2" mulch layer to areas of earth disturbance, equivalent to double the standard rate. Mulch should be tracked in open areas vulnerable to wind. Seeding with winter rye is recommended to allow for early germination during wet spring conditions. Requirements for Winter Construction If construction activities involving earth disturbance continue into the winter construction period, the following requirements apply: 1. Enlarged access points, stabilized to provide for snow stockpiling. 2. Snow shall be managed with adequate storage and control of meltwater, requiring cleared snow to be stored down slope of all areas of disturbance and out of stormwater treatment structures. 3. For areas of disturbance within 100 ft of a waterbody, the following must be installed across the slope, down gradient of the earth disturbance: a combination of one practice from group A placed in front of a practice from group B, or two group B practices, or a single row of Reinforced Silt Fence 4. Drainage structures must be kept open and free of snow and ice dams. 5. Silt fence and other practices requiring earth disturbance must be installed ahead of frozen ground. 6. Mulch used for temporary stabilization must be applied at a minimum of 2 inches with an 80-90% cover. 7. To ensure cover of disturbed soil in advance of a precipitation or melt event, areas of disturbed soil must be stabilized prior to any runoff producing event. Stabilization is not required if the work is occuring in a self-contained excavation (i.e. no outlet) with a depth of 2 feet or greater (e.g. house foundation excavation, utility trenches), provided any dewatering, if necessary, is conducted in accordance with Part 13. 8. Prior to stabilization, snow or ice must be removed to the extent practicable. 9. Use stone to stabilize areas such as the perimeter of buildings under construction or where construction vehicle traffic is anticipated. Stone paths should be sufficient width to accommodate vehicle or equipment traffic. 13.Dewatering Activities Purpose: To minimize and prevent discharges of sediment as a result of dewatering activities. Requirements: Stormwater and groundwater from dewatering activities shall be uncontaminated and shall be filtered or passed through a sediment trapping device, or both, and routed in a manner that does not result in visually turbid discharges to waters. Pump intake for dewatering must be at or near the surface of the ponding area to prevent disturbance of the settled material. Visually turbid water must not be pumped directly to storm drains or other conveyance that leads to waters without implementing one or more of the practices described below. How to comply: Implement one or more of the following practices when dewatering: Implement sock filters or sediment filter bags on dewatering pump discharge hoses or pipes. Route dewatering pump into silt fence enclosures or into staked hay bale enclosures lined with fabric. Route dewatering pump to vegetated area at least 50 feet from surface waters and at a slope no greater than 5%. Remove accumulated sediment after the water has dispersed or infiltrated and stabilize the area with seed and mulch as necessary. A sufficient area of vegetation greatly improves the efficacy of filtering/settling of turbid water discharged from a dewatering enclosure. 14.Concrete Washout Purpose: Concrete wash water often contains a slurry of heavy metals, can be caustic, and has a high pH. As a result, concrete washwater is not a permitted discharge. Requirements: Concrete washwater and excess washout concrete should go in a lined washout. This washout should be accessible to the cement truck and at least 50 feet away from stormwater inlets and surface water. Concrete Washout Installation: If cement washout is going to occur on site, a lined concrete washout as shown below shall be used onsite. Care should be given to assure that the washout does not overtop during a storm event. Proprietary lined and contained concrete washout basins may also be utilized in accordance with manufacturer's specifications. Concrete Washout Maintenance: Concrete washout shall be pumped to a concrete truck as necessary, for disposal or reuse at a batch plant. Washout may also be allowed to evaporate/harden for disposal in accordance with all applicable local, state, and federal regulations. 15.Permanent Controls Permanent stormwater treatment practices are constructed to maintain water quality, preserve existing water table elevations, prevent downstream flooding, and are often required for a project under a Vermont operational stormwater discharge permit applicable to the construction or redevelopment of impervious surfaces.* Permanent Stormwater Treatment Practices (STPs) include infiltration and filtering practices as well as detention ponds and treatment wetlands. It is critical that infiltration practices do not receive runoff until the site area has reached final stabilization. The outlet of permanent controls that are used as temporary storage and sediment basins during construction constitutes a potential discharge point and therefore must be managed to minimize and prevent sediment laden stormwater discharges. These practices will often need to be reshaped to meet the operational design criteria for volumes, grades and geometry once final grading and stabilization has occurred. 16.Inspection, Maintenance, and Discharge Reporting Site inspections are required to ensure that all erosion prevention and sediment control practices are sufficient and functioning properly. Regular inspections and maintenance of practices will help to reduce costly repairs and minimize the risk to water quality from construction stormwater discharges. Requirements: Inspect the site at least once every 7 days and after every rainfall or snowmelt that results in stormwater runoff. Perform maintenance to ensure that practices are functioning according to the specifications outlined in this handbook. In the event of a visibly turbid discharge from the construction site, you must take immediate action to inspect and maintain existing erosion prevention and sediment control practices. Additional erosion prevention and sediment control measures must be installed as necessary, including temporary stabilization, to minimize and prevent the discharge of sediment laden stormwater runoff. If after maintaining and supplementing BMPs, a discharge of visibly discolored stormwater from the construction site to surface waters continues, the permittee is required to notify DEC within 24 hours. While documentation of a routine inspection is not required, example inspection forms and forms for required discharge reporting are available at the Stormwater Program website. Permittees shall review Construction General Permit 3-9020 for all discharge reporting requirements. A copy of the Low Risk Site Handbook shall be kept on-site. Daily inspections are required from October 15 through April 15. MULCH NOTE: MULCH FOR PURPOSES OTHER THAN HYDROSEEDING WILL BE CLEAN STRAW, FREE FROM WEEDS. HAY MULCH WILL NOT BE ALLOWED TO AVOID THE SPREAD OF NON-NATIVE SPECIES SUCH AS WILD PARSNIP. 01/05/2023 LOT 6 SUBDIVISION 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Detail.dwg, 1/5/2023 9:55:36 AM, DWG To PDF.pc3 AS SHOWN 22117 C4.0 A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com DSM DSM MAB DETAILS N.T.S. TYPICAL DRIVEWAY SECTION S-030S-030 Driveway Section4" CRUSHED GRAVEL - FINE AOT SPECIFICATION 704.05 SEPARATION/STABILIZATION GEOTEXTILE COMPACTED SUBGRADE BITUMINOUS CONCRETE PAVEMENT 2" TYPE III 8" DENSE GRADED CRUSHED STONE AOT SPECIFICATION 704.06 12" MINIMUM SHOULDER REVISED 01/21/2021 3 1 OR AS SHOWN ON PLANS 4" MINIMUM TOPSOIL, SEED AND MULCH ALL SIDESLOPE - USE EROSION MATTING (WHEN REQUIRED) TO ESTABLISH VEGETATION, PARTICULARLY ON LOW SIDE OF ROADWAY N.T.S. DRIVE CURB CUT DETAIL S-007S-007 Curb Cut16'-0" DRIVE CURB CUT (TYP. ) - TO BE FIELD LOCATED 6'-0"6'-0" REINFORCE CONCRETE CURBING AT DRIVEWAY CUTS 112" CURB REVEAL AT CURB CUTS SEE TRANSITION CURB DETAIL BEGIN TRANSITION SLOPE SEE CONCRETE CURB DETAIL SEE ROAD SECTION DETAIL REVISED 08/01/2014 NOTES: PAVED N.T.S. D D+2' 6" 6" TYPICAL SEWER TRENCH DETAIL5'-0" MIN. COVER (PLOWED AREAS)4'-0" MIN. COVER (TYPICAL)6" 1. COMPACTION OF BACKFILL AND BEDDING SHALL BE A MINIMUM OF 90% (95% UNDER ROADWAY SURFACES) OF MAXIMUM DRY DENSITY DETERMINED IN THE STANDARD PROCTOR TEST (ASTM D698). 2.BEDDING MATERIAL SHALL NOT BE PLACED ON FROZEN SUBGRADE. 3.APPROVED BACKFILL SHALL NOT CONTAIN ANY STONES MORE THAN 12" IN LARGEST DIMENSION (6" IN ROADWAYS, 1 1/2"" MAXIMUM DIAMETER WITHIN 24" OF THE OUTSIDE OF THE PIPE), OR CONTAIN ANY FROZEN, WET, OR ORGANIC MATERIAL. 4.TRENCHES SHALL BE COMPLETELY DEWATERED PRIOR TO PLACING OF PIPE BEDDING MATERIAL AND KEPT DEWATERED DURING INSTALLATION OF PIPE AND BACKFILL. 5.IN TRENCHES WITH UNSTABLE MATERIALS OR HIGH WATER TABLE, TRENCH BOTTOM SHALL FIRST BE STABILIZED BY PLACEMENT OF FILTER FABRIC THEN CRUSHED STONE (3/4" MAXIMUM). 6.THE SIDES OF TRENCHES 4' OR MORE IN DEPTH ENTERED BY PERSONNEL SHALL BE SHEETED OR SLOPED TO THE ANGLE OF REPOSE AS DEFINED BY O.S.H.A. STANDARDS. 7.BEDDING MATERIAL FOR WASTEWATER LINES SHALL CONSIST OF CRUSHED STONE, GRAVEL, OR SAND WITH A MAXIMUM SIZE OF 34". SUBMIT A SAMPLE TO THE ENGINEER FOR APPROVAL. 8.ALL JOINTS TO BE INSPECTED BY OWNER/ENGINEER/TOWN PRIOR TO BACKFILL. APPROVED BACKFILL THOROUGHLY COMPACTED IN 8" LIFTS 2" RIGID INSULATION WHEN DEPTH OF PIPING IS LESS THAN MINIMUM NOTED 4" WIDE MAGNETIC "SEWER" TAPE INSTALLED APPROX. 2' BELOW SURFACE SEWER LINE, SEE PLAN FOR TYPE AND SIZE PIPE BEDDING UNDISTURBED SOIL OR ROCK TOPSOIL, RAKE, SEED & MULCH UNPAVED REVISED 12/08/2016SWR-001SWR-001 Trench(SEE SITE PLAN)5'-0" MIN. COVER OVER FORCE MAINSN.T.S. TYPICAL CLEANOUT DETAIL REVISED 10/07/2015SWR-009SWR-009 CO Pvc/RebarGRASS 4" SDR 35 PVC NOTES: 1.CONTRACTOR SHALL PROVIDE TWO TIES TO ALL BURIED C.O.'s ON THE AS-BUILT PLANS SUBMITTED TO THE OWNER. 2.CLEANOUT TO BE INSTALLED AT INTERVALS OF NOT MORE THAN 100 FEET, AND UPSTREAM OF BEND(S) IN BUILDING SEWER(S) WHEN CHANGE IN PIPE DIRECTION EXCEEDS 45° (USE LONG SWEEP FITTINGS WHEN EXCEEDING 45°) 4" PVC SDR 35 45° ELBOW FINISH GRADE 4" PVC CAP 4"±VERTICAL REBAR FOR LOCATING CLEANOUT WITH METAL DETECTOR 300 PSI CONCRETE CRADLE w/ 3 MIL POLYETHYLENE PLACED BETWEEN PIPE & CONCRETE NOTES: PAVED N.T.S. D D+2' 6" 6" TYPICAL WATER TRENCH DETAIL6'-0" MIN. COVER1. COMPACTION OF BACKFILL AND BEDDING SHALL BE A MINIMUM OF 90% (95% UNDER ROADWAY SURFACES) OF MAXIMUM DRY DENSITY DETERMINED IN THE STANDARD PROCTOR TEST (ASTM D698). 2.BEDDING MATERIAL SHALL NOT BE PLACED ON FROZEN SUBGRADE. 3.APPROVED BACKFILL SHALL NOT CONTAIN ANY STONES MORE THAN 12" IN LARGEST DIMENSION (6" IN ROADWAYS, 1 1/2"" MAXIMUM DIAMETER WITHIN 24" OF THE OUTSIDE OF THE PIPE), OR CONTAIN ANY FROZEN, WET, OR ORGANIC MATERIAL. 4.TRENCHES SHALL BE COMPLETELY DEWATERED PRIOR TO PLACING OF PIPE BEDDING MATERIAL AND KEPT DEWATERED DURING INSTALLATION OF PIPE AND BACKFILL. 5.IN TRENCHES WITH UNSTABLE MATERIALS OR HIGH WATER TABLE, TRENCH BOTTOM SHALL FIRST BE STABILIZED BY PLACEMENT OF FILTER FABRIC THEN CRUSHED STONE (3/4" MAXIMUM). 6.THE SIDES OF TRENCHES 4' OR MORE IN DEPTH ENTERED BY PERSONNEL SHALL BE SHEETED OR SLOPED TO THE ANGLE OF REPOSE AS DEFINED BY O.S.H.A. STANDARDS. 7.BEDDING MATERIAL SHALL CONSIST OF CRUSHED STONE, OR SAND WITH A MAXIMUM SIZE OF 34". SUBMIT A SAMPLE TO THE ENGINEER FOR APPROVAL. 8.CONTRACTOR TO INSTALL TRACER WIRE ALONG ALL SECTIONS OF NEW WATER LINE. TERMINATE TRACER WIRE AT ALL VALVE BOXES AND HYDRANTS. COORDINATE INSTALLATION WITH TOWN AND ENGINEER. APPROVED BACKFILL THOROUGHLY COMPACTED IN 8" LIFTS 2" RIGID INSULATION WHEN DEPTH OF PIPING IS LESS THAN 6'-0" WATER LINE, SEE PLAN FOR TYPE AND SIZE PIPE BEDDING UNDISTURBED SOIL OR ROCK TOPSOIL, RAKE, SEED & MULCH UNPAVED REVISED 12/08/2016W-001 D/2 INSTALL UTILITY LOCATOR RIBBON OVER WATER MAIN APPROX. 2' BELOW SURFACE TRACER WIRE (VERIFY TYPE WITH TOWN/ENGINEER PRIOR TO START OF CONSTRUCTION)W-001 Trench(SEE SITE PLAN) N.T.S. WATER/SEWER CROSSING W-007W-007 Water-Sewer CrossingWATER MAIN PROFILE VIEW18"MIN.18"MIN.GRAVITY SEWER OR FORCE MAIN (JOINTS TO BE ENCASED) GRAVITY SEWER OR FORCE MAIN PLAN VIEW WATER MAIN SEWER MAIN10' MIN.10' MIN.10' MIN.10' MIN.SINGLE 20' LENGTH OF WATER QUALITY PIPE ENCASEMENT IF SEPARATION IS BETWEEN 12" TO 18" THE GRAVITY SEWER or FORCE MAIN JOINTS SHALL BE CONCRETE ENCASED WHEN LOCATED ABOVE THE WATER MAIN REVISED 5/4/2021 COMPLY WITH REQUIREMENTS OF VERMONT WASTEWATER SYSTEM AND POTABLE WATER SUPPLY RULES, SECTION 1-1007 - "SEPARATION OF SANITARY SEWER SERVICE LINE AND SANITARY SEWER COLLECTION LINES FROM WATER MAINS, WATER SERVICE LINES AND WATER SERVICE PIPES" REVISED 11/07/2014W-100W-100 Min. Sep.Non-sewage Wastewater Disposal Fields Hazardous or Solid Waste Disposal Site Concentrated Livestock Holding Area & Manure Storage Systems Buildings Flood ways Surface Water Limit of Herbicide Application on Utility R.O.W. Property Line Subsurface Wastewater Piping and Related Tanks Sewage System Disposal Fields Driveway (less than 3 residences) Roadway, Parking Lot (outer edge of shoulder) and other Siting Limitations Potential Source of Contamination VERMONT WATER SUPPLY RULE - CHAPTER 21 TABLE A11-1 - REQUIRED MINIMUM SEPARATION DISTANCES a.See Table 11-2, FIG 11-1 OF VT WATER SUPPLY RULE, CH. 21 b.Increased to 50' when adjacent to agricultural cropland. c.Applies to rights-of-way (ROW) where herbicides have been applied in the past 12 months or may be applied in the future. This distance may be increased to 200' depending on the active ingredient in the herbicide according to Vermont Regulations for Control of Pesticides. d.For Public water sources, see Appendix A, part 3, Subpart 3.3.8. e.Water sources shall not be located in a flood way. f.If a water source is potentially downgradient of a source of contamination, then the Agency shall apply the criteria in 11.4.2.2. f. f. 200' 10' e. 10'd 100'c 10'b 50' a. 15' 25' Separation Distance 01/05/2023 LOT 6 SUBDIVISION 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 N.T.S. WATER SERVICE CONNECTION REVISED 2/23/2015W-006W-006 Serv Con1" MAX.6'-0" MIN.6'-0" MIN.6" MIN. UNDISTRUBED SOIL 4"x8"x16" SOLID CONCRETE BLOCK CURB STOP ADJUSTABLE IRON CURB BOX w/ LID MARKED "WATER" - CONTRACTOR TO COORD. FINAL CURB STOP COVER WITH LOCAL WATER DEPT. PROPERTY LINE OR EASEMENT BOUNDARY STATIONARY ROD INSTALL A GOOSE NECK LOOP WATER MAIN TYPE 'K' COPPER SERVICE OR AS SHOWN ON PLANS CORPORATION (SEE PLAN FOR SIZE) FINISH GRADE NOTE: 1. SEE SPECIFICATIONS FOR ADDITIONAL TAPPING SADDLE, CORPORATION, AND CURB STOP REQUIREMENTS. N.T.S. ELECTRICAL TRENCH - SECONDARY REVISED 08/01/2014M-008M-008 Elec Trench Secondary24" MIN.24" MIN. 12" MIN. APPROVED BACKFILL THOROUGHLY COMPACTED IN 8" LIFTS ELECTRICAL CABLE MARKING TAPE SHALL BE PLACED 8" TO 12" BELOW FINISH GRADE TELEPHONE CABLE MIN. 4" SAND OR FINE GRAVEL ON ALL SIDES OF CONDUIT ELECTRICAL CONDUIT N.T.S. REPLACEMENT OF EXISTING PAVEMENT NOTES: 1. THE CONTRACTOR SHALL MAINTAIN AT LEAST ONE-WAY TRAFFIC AT ALL TIMES DURING WORK WITHIN THE R.O.W. 2.MAINTENANCE AND PROTECTION OF TRAFFIC DURING WORK WITHIN THE HIGHWAY R.O.W. SHALL BE PROVIDED IN ACCORDANCE WITH THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. THE CONTRACTOR SHALL NOT WORK WITHIN THE R.O.W. WITHOUT APPROPRIATE CONSTRUCTION SIGNING IN PLACE. 3.ALL BACKFILL SHALL BE MADE IN SIX INCH (6") LIFTS AND COMPACTED TO NOT LESS THAN 95% MAXIMUM DRY DENSITY ACCORDING TO ASTM D698. 4.REPLACE EXISTING ROAD STRIPING AS NECESSARY. S-005S-005 Replace Ex. PavREVISED 09/29/2014 NEW BIT. CONC. PAVEMENT MATCH EX. SUBBASE (18" MIN. CRUSHED GRAVEL) EXIST. SUBBASE BOTH SIDES SMOOTH CUT EXIST. BIT. PAVEMENT PRIOR TO PAVING 1'-0" (MIN.) SEE TYPICAL TRENCH DETAIL D + 2' TRENCH EXCAVATION (MIN.) MATCH EX. PAVEMENT (4" MIN. - 112" TYPE III - 212" TYPE II) ALL JOINTS SHALL BE THOROUGHLY CLEANED AND COATED WITH EMULSIFIED ASPHALT PRIOR TO PAVING EXIST. BIT. PAVEMENT (BOTH SIDES)P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Detail.dwg, 5/3/2023 9:07:33 AM, DWG To PDF.pc3 AS SHOWN 22117 C5.0 A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com DSM DSM MAB SPECIFICATIONS 01/05/2023 LOT 6 SUBDIVISION 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Detail.dwg, 1/5/2023 9:55:46 AM, DWG To PDF.pc3 ” AS SHOWN 22117 C5.1 A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com DSM DSM MAB SPECIFICATIONS 01/05/2023 LOT 6 SUBDIVISION 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Detail.dwg, 1/5/2023 9:55:50 AM, DWG To PDF.pc3 √√ AS SHOWN 22117 C5.2 A C CIVIL ENGINEERING ASSOCIATES, INC. E 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com DSM DSM MAB SPECIFICATIONS 01/05/2023 LOT 6 SUBDIVISION 1200 DORSET STREET SOUTH BURLINGTON, VT 05403 1200 DORSET, LLC AND THE HIGHLAND DEVELOPMENT CO., LLC. 1200 DORSET STREET SOUTH BURLINGTON VERMONT 05403 P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-Detail.dwg, 1/5/2023 9:55:55 AM, DWG To PDF.pc3 PSGGGGGGGG EXISTING REC PATHRESTRICTED BUILD AREATO SWIFT STREETTO OLD CROSS ROADEXIST. 10' GMP EASE. n/f COMMON LAND W WWHOLL O W MEDALIST EX. WATER SERVICE10' SETBACK 10' SETBACK 20' SETBACK20' SETBACK 20'SETBACKMAILBOX PUMP STATION SID E W A L K SIDE WALK SIDEWALK SIDEWALK60' R.O .W . OF DORSET STREET R.O.W.Exist. Lot 6 Highlands Development Company, LLC V. 1221 Pg. 262 1.289± Acres FOULSHAM ROA D DR .EXISTING REC PATHLOT 6A 0.687± Ac. LOT 5 LOT 1DORSET STREET(PRVT.)J.K. Rustad & D.M. Discano V. 1333 P. 144 Highlands Residential Properties, LP V. 401 P. 49 Ila Isham #50 #76 S 86°15'37" W NEW LINE 83.42'SS10' SEWER EASEMEN T 10' WATER EASEMEN T NEW UTIL. POLE LOT 6B 0.602±Ac. DRIVEWAY DRIVEWAY R.O.W. 0.86± Acre "Lot 173" R.O.W. 0.86 ± A c. N 68° 5 6 ' 4 5 " W 7 2 . 0 6 ' EXIST. 10' GMP EASE. SERVING LOT 6A SERVING LOT 6A 10' SETBACK 20' SETBACK10' S E T B A C K 20' SETBACK16' ACCESS EASEMENT (SHADED) 2 Lot Subdivision of: 1200 Dorset Street, for Highlands Development Co., LLC 1200 Dorset St. & Foulsham Hollow Road South Burlington, Vermont Grid North Survey Note 2 22117 1" = 30' FEB. 27, 2023 TRC CEA P1 802-864-2323 www.cea-vt.com 10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403 CIVIL ENGINEERING ASSOCIATES, INC. A C E Location Map Not to Scale - Referenced Plats - A."Paul F. Heald 6-Lot Subdivision Plat, Dorset Street" prepared by Civil Engineering Associates, Inc., dated August 2001 and Last Revised 12/4/2001. Vol. 495 Pg. 86 South Burlington Land Records. B."Eonomou Farms Golf Course Plat - Southeast Parcel, Property of JAM GOLF, LLC" prepared by Civil Engineering Associates, Inc., dated May 1996. South Burlington Land Records. RECEIVED FOR RECORDING IN THE LAND RECORDS OF THE CITY of SOUTH BURLINGTON, VERMONT, AT______________ O'CLOCK ON THE ______ DAY OF __________, 20_____. ATTEST: ____________________________, CITY CLERK APPROVED BY RESOLUTION OF THE DEVELOPMENT REVIEW BOARD OF THE CITY of SOUTH BURLINGTON, VERMONT, ON THE _____ DAY OF _____________, 20____, SUBJECT TO THE REQUIREMENTS AND CONDITIONS OF SAID RESOLUTION. SIGNED THIS _____ DAY OF ______________, 20______. BY ___________________________________, CHAIRPERSON To the best of my knowledge and belief this plat depicts the results of a survey conducted by me as described in "Survey Notes" above, based upon our analysis of land records and evidence found in the field. Existing boundaries shown are in substantial conformance with the records, except as noted. This plat is in substantial compliance with 27 VSA 1403, "Recording of Land Plats". This statement valid only when accompanied by my original signature and seal. - Survey Notes - 1. Purpose of this survey plat is to depict the subdivision of existing Lot 6 of the Paul Heald Subdivision (Reference Plat A) into two lots, "6A" and "6B". Lot 6 was conveyed to Highlands Development Company, LLC by Limited Warranty Deed of New England Federal Credit Union dated June 25, 2014 and recorded in Volume 1221 at Page 262 of South Burlington Land Records. Other neighboring property lines and buildings shown MAY be approximate only, and are shown for information purposes only. 2. Field survey was conducted summer 2022 and consists of a closed-loop traverse utilizing a robotic total station instrument. Bearings shown are from Grid North, Vermont Coordinate System of 1983, based upon our GPS observations on or adjacent to the site (Reference Frame NAD83 (2011, Epoch 2010)). 3. Iron pipes shown as “found” are typically labeled with inside diameter, rods with outside diameter, unless otherwise indicated. Condition of pipes, rods and markers found are “good” unless otherwise noted. Corners denoted "Set" or “Proposed” typically consist of 5/8” diameter rebar capped with aluminum disks stamped “Civil Engineering Assocs. - VT LS 597”, typically set flush with existing grade. Progr e s s - Easement Notes - E.1. Existing Lot 6 and Proposed Lots 6A & 6B are served by an easement and right of way over a parcel of land depicted as "ROW 0.86 AC" on Reference Plat A. E.2. Proposed Lot 6A shall be served by the following three (3) easements over portions of Lot 6B as follows: ·16' wide easement for 12' wide shared driveway (centered on drive as built) ·10' wide easement for water line (centered on pipe as built) ·10' wide easement for sewer line (centered on pipe as built) Progr e s s 02/2 7/ 2 3 FM OE G ST S W Overhead Electric Forcemain Gas Storm Gravity Sewer Water Setback Line Property Line Easement Line - Legend - Sewer manhole Storm manhole Catch basin Hydrant Capped rod previously set Concrete monument found S D Light pole Utility pole NEW SURVEY MARKER _____________________________ Timothy R. Cowan VT LS 597 4. Not being within the scope of this survey, Civil Engineering Associates, Inc. has conducted no investigation whatsoever respecting whether or not the property and each component thereof is in compliance with state or local permits. 5. Any utilities shown do not purport to constitute or represent all utilities located upon or adjacent to the surveyed premises and are approximate only. Any buried utilities shown are depicted based solely on surface indications; actual locations may vary. Contact Dig Safe (888-344-7233) prior to any excavation or construction. GENERALLY, THE TERM "NEW" ON THIS PLAT DENOTES "PROPOSED" PROJECT LOCATION P:\AutoCADD Projects\2022\22117-Highland Development\1-CADD Files-\dwg\22117-PLAT.NEW.dwg, 5/2/2023 1:31:16 PM, DWG To PDF.pc3 LOT 6A SOUTH FACADE - MATERIAL/STRUCTURE LIKENESSCovered front porchShingle Roof - Dark ColorSetback Garagefacade DN2345671109111312111415STAIR812DNUP3'-0" x 7'-0" VITREOUS CHINATOILETHIGHLINEK-3999-RZDBLOVEN 12'-612"29'-0"16'-0"8'-0"8'-0"26'-0"8'-0"6'-0" 50'-0"12'-0"8'-0"7'-0"30'-612"6'-0"ENTRYPORCHENTRYFOYEROFFICE11x13.5POWDERKITCHEN13x13.5PANTRY5.5x7MUDROOM7.5x8.5CLOSET5x7.5KITCHEN"26x28"DINING12.5x13.5LIVING15x20.5PORCH8x14POTENTIAL DECK16x29REFCOFFEE BAR DN10234812PROJECTNORTHFIRST FLOOR PLANScale: 1/4" = 1'-0"FIRST FLOOR PLAN1Drawn By:TPOSheet:Date:15 MAY 2023Revisions:SHEET INFORMATION DOUGLASS RESIDENCE6 6554433221A1BCDBACDPROPOSED Checked By:x SOUTH BURLINGTON, VERMONTA2 TiMic Drafting &Designworking for your visionOffices inThetford & Montpelier, VtT:802.683.7027M:802.793.68621200 DORSET STREET SOUTH HEATED SQFT:FIRST FLOOR: 1,394SECOND FLR: 1,778TOTAL:3,176GARAGE: 728Preliminary05/15/2023 9:03:25 AMLot 6A 1st Floor Plan STAIRDN23456711091113141581216VITREOUS CHINATOILETHIGHLINEK-3999-RZ VITREOUS CHINATOILETHIGHLINEK-3999-RZ VITREOUS CHINATOILETHIGHLINEK-3999-RZ 29'-0"16'-0"50'-0" 8'-0"34'-0"8'-0"12'-0"8'-0"25'-0"MAIN SUITE14.5x15BEDROOM 211.5x14.5MAIN SUITEBATHMAIN SUITECLOSET 18x8CLOSETLAUNDRY6.5x11.5BEDROOM 113x13.5BEDROOM 1BATHMAIN SUITECLOSET 25.5x10BEDROOM 311.5x14.5BATH 1LINEN/ CUBBIES LINEN/ CUBBIES LINEN CLOSET CLOSET10234812PROJECTNORTHSECOND FLOOR PLANScale: 1/4" = 1'-0"SECOND FLOOR PLAN1Drawn By:TPOSheet:Date:15 MAY 2023Revisions:SHEET INFORMATION DOUGLASS RESIDENCE6 6554433221A1BCDBACDPROPOSED Checked By:x SOUTH BURLINGTON, VERMONTA3 TiMic Drafting &Designworking for your visionOffices inThetford & Montpelier, VtT:802.683.7027M:802.793.68621200 DORSET STREET SOUTHPreliminary05/15/2023 9:03:31 AMLot 6A 1st Floor Plan BUILDING ELEVATIONS Scale: 1/4" = 1'-0"SOUTH ELEVATION1Drawn By:TPOSheet:Date:15 MAY 2023Revisions:SHEET INFORMATION DOUGLASS RESIDENCE6 6554433221A1BCDBACDPROPOSED Checked By:x SOUTH BURLINGTON, VERMONTA5 TiMic Drafting &Designworking for your visionOffices inThetford & Montpelier, VtT:802.683.7027M:802.793.68621200 DORSET STREET SOUTHScale: 1/4" = 1'-0"WEST ELEVATION2Preliminary05/15/2023 9:03:33 AMLot 6A ElevationsAvg = 25.87'30.43 ft 21.31 ft ELEVATIONS Drawn By:TPOSheet:Date:15 MAY 2023Revisions:SHEET INFORMATION DOUGLASS RESIDENCE6 6554433221A1BCDBACDPROPOSED Checked By:x SOUTH BURLINGTON, VERMONTA6 TiMic Drafting &Designworking for your visionOffices inThetford & Montpelier, VtT:802.683.7027M:802.793.68621200 DORSET STREET SOUTHScale: 1/4" = 1'-0"NORTH ELEVATION1Scale: 1/4" = 1'-0"EAST ELEVATION1Preliminary05/15/2023 9:03:34 AMLot 6A Elevations NORTH FACING GARAGEPITCHED, SHINGLE ROOF, DARK COLOREXPOSED FOUNDATION ELEVATION CHANGE TO REDUCEGRADING AND TO FACILIATE WALKOUTFRONT PORCH FACING FOULSHAMHOLLOW ROAD.LOT 6B EAST (and SOUTH) FACADE - MATERIAL/STRUCTURE LIKENESS WINDOWS ON THE WEST SIDE OF THEGARAGE/HOUSEPEAKED SHINGLE ROOF -DARK COLORSPORCH FACING DORSET STREET.LOT 6B WEST FACADE - MATERIAL/STRUCTURE LIKENESSAvg. 23.33'30.75 ft 15.91 ft