Loading...
HomeMy WebLinkAboutSD-23-10 - Supplemental - 0255 Kennedy Drive (17)© 2021 UltraLights LightingUltraLights The Heart of Illumination | 520.623.9829 | ultralightslighting.com Cylo 19413 project name:modifications: project location: specifier name: specifier location: quantity: fixture type: Notes Dark Sky friendly available — ±$ Inquire. Marine grade primer available — ±$ Inquire. Base Specs 19.5"h x 6"w x 4"d Opal Acrylic Bottom Diffuser © 2021 UltraLights LightingUltraLights The Heart of Illumination | 520.623.9829 | ultralightslighting.com Cylo 19413 BA - Bronze Age BK - Black BP - Black Pearl CB - Cast Bronze CH - Chestnut CR - Chrome DI - Dark Iron EB - Empire Bronze MB - Medieval Bronze NB - New Brass SB - Smokey Brass SP - Satin Pewter SS - Smoked Silver standard finish: OA - Opal Acrylic standard diffuser: 02: 16.8w Integrated LED, 2362 Initial Lumens, 3000K, 90 CRI, 120V, Standard Phase Dimming, UL/cUL Wet 04: 16.8w Integrated LED, 2362 Initial Lumens, 3000K, 90 CRI, 120V-277V, 0-10V Dimming, UL/cUL Dry/Damp 10: Wattage Restriction Label - 2 x E26 for LED Retrofit 20W max ea - A-Type, 120V, Standard Phase Dimming, UL/cUL Dry/Damp 14: 16.8w Integrated LED, 2362 Initial Lumens, 3000K, 90 CRI, 120V, Standard Phase Dimming, UL/cUL Dry/Damp lamping: techlighting.com DELIVERED LUMENS 1163 WATTS 47.2 VOLTAGE 120V, 277V DIMMING ELV LIGHT DISTRIBUTION Symmetric MOUNTING OPTIONS Downlight CCT 2700K**, 3000K CRI 80+ COLOR BINNING 3 Step BUG RATING B1-U0-G0 DARK SKY Compliant WET LISTED IP65 GENERAL LISTING ETL CALIFORNIA TITLE 24 Can be used to comply with CEC 2019 Title 24 Part 6 for outdoor use. Registration with CEC Appliance Database not required. START TEMP -30°C FIELD SERVICEABLE LED No CONSTRUCTION Aluminum HARDWARE Stainless Steel FINISH Powder Coat LED LIFETIME L70; >60,000 Hours WARRANTY*5 Years WEIGHT 3.2 lbs. * Visit techlighting.com for specific warranty limitations and details. ** Available in Black and Bronze finish only. PRODUCT LENGTH FINISH LAMP 700WSBOW 6 6"B BLACK Z BRONZEH CHARCOALI SILVER W WHITE -LED827 LED 80 CRI, 2700K 120V* -LED827277 LED 80 CRI, 2700K 277V*-LED830 LED 80 CRI, 3000K 120V-LED830277 LED 80 CRI, 3000K 277V *AVAILABLE IN BLACK AND BRONZE FINISH ONLY BOWMAN 6 WALL SCONCE Outstanding protection against the elements: • Powder coat finishes • Stainless Steel mounting hardware • Impact-resistant, UV stabilized frosted acrylic lensing The classic silhouette of this sleek LED wall sconce makes it suitable for both indoor and outdoor applications. The Bowman’s die-cast aluminum body houses a powerful, long-lasting LED light source tightly controlled for down light only, yet supplying significant illumination for even the darkest nights. Available in two sizes and five finishes. ORDERING INFORMATION SPECIFICATIONS BOWMAN 6 shown in black BOWMAN 6 shown in charcoal BOWMAN 6 shown in bronze BOWMAN 6 shown in silver BOWMAN 6 shown in white FIXTURE TYPE & QUANTITY PROJECT INFO JOB NAME & INFO NOTES 7400 Linder Avenue, Skokie, Illinois 60077 T 847.410.4400© 2020 Tech Lighting, L.L.C. All rights reserved. The "Tech Lighting" graphic is a registered trademark. Tech Lighting reserves the right to change specifications for product improvements without notification. techlighting.com 6"152 mm 7.5"191 mm 9"229 mm J-BoxCenterline 2.6"66 mm BOWMAN 6 WALL SCONCE Bowman 6 PHOTOMETRICS**For latest photometrics, please visit www.techlighting.com/OUTDOOR BOWMAN 6 Total Lumen Output: 1163 Total Power: 47.2 Luminaire Efficacy: 24.6 Color Temp: 3000K CRI: 80+ BUG Rating: B1-U0-G0 180˚ 683 820 547 410 273 137 0 137 273 410 547 683 820 170˚160˚150˚140˚ 130˚ 120˚ 110˚ 100˚ 90˚ 80˚ 70˚ 60˚ 50˚ 40˚30˚20˚10˚0˚ SlimSurface is a 5/8" thick LED surface mounted luminaire with the appearance of a recessed downlight. Easy to install into most standard j-boxes, the SlimSurface round apertures are available as a 5" 650 lm, 7" 1000 lm and 10" 2200 lm fixture. Project: Location: Cat.No: Type: Lamps: Qty: Notes: SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 1 of 9 Downlighting SlimSurface LED S5R, S7R & S10R Round 5", 7" and 10" Apertures Ordering guide example: S5R830K7AL Series CRI CCT Lumens Finish Dimming S5R SlimSurface 5" Round 8 80 9 90 1 27K 2700K 30K 3000K 35K 3500K 40K 4000K 7 650 lm — White AL Aluminum BK Black blank ELV / Triac (120V) W White AL AluminumBK Black Z10U 0-10V (120V-277V) S7R SlimSurface 7" Round 8 809 90 1 27K 2700K30K 3000K35K 3500K40K 4000K 10 1000 lm — WhiteAL AluminumBK Black blank ELV / Triac (120V) W WhiteAL AluminumBK Black Z10U 0-10V (120V-277V) S10R SlimSurface 10" Round 2 8 80 9 90 1 27K 2700K 30K 3000K 35K 3500K 40K 4000K 22 2200 lm W White AL Aluminum BK Black MT Metallic blank ELV / Triac (120V) Z10U 0-10V (120V-277V) 1. Configurations using 90 CRI are only available with 2700K & 3000K CCT. 2. IMPORTANT: SlimSurface LED 10" round installs into 4-11/16" J-box (not wet location listed). Features 1. Flange: One piece plastic flange. Injection molded white, applied aluminum or black. 2. Lens: High transmittance lens allowing for smooth, comfortable light pattern. 3. Power supply: Integral class 2 driver. Factory wired electronic LED driver (see Electrical section for specifications) 4. LED Strip: Utilizes LEDs. 5. Lifetime: Expected lifetime 50,000 hours and backed by a 5-year warranty* 6. Compliance: Non-conductive fixture for shower light application (not applicable to metal trim model). Dimming Intended for ELV/Triac (120V) or 0-10V dimming (120V-277V) based on the configuration. Min 90°C supply conductors. Electrical Electronic power supply: RoHS compliant. Class 2 power unit. Unit tolerates sustained open and short circuit output conditions without damage. Labels cULus listed. ENERGY STAR® certified. All models are damp location rated for walls or ceilings. The 5" & 7" are suitable for ceiling mount wet locations when installed per instructions. White Black Aluminum Metal Electrical specifications Dimming Input volts Input frequency Input current Input Power THD Factor Power Factor Minimum Operating Temp. Slim 5" 650lm Triac 120V 50/60Hz 0.08A 9.5W <15%>0.9 -20°C 0-10V 120V 50/60Hz 0.09A 10.1W <20%>0.9 -20°C 277V 50/60Hz 0.04A 10.2W <20%>0.9 -20°C Slim 7" 1000lm Triac 120V 50/60Hz 0.13A 14.2W <15%>0.9 -20°C 0-10V 120V 50/60Hz 0.12A 14.4W <20%>0.9 -20°C 277V 50/60Hz 0.06A 14.7W <20%>0.9 -20°C Slim 10" 2200lm Triac 120V 50/60Hz 0.20A 23.2W <20%>0.9 -20°C 0-10V 120V 50/60Hz 0.20A 23.2W <10%>0.95 -20°C 277V 50/60Hz 0.09A 24.6W <15%>0.95 -20°C Fore more details, please see LED-DIM-DL spec sheet. * See Philips.com/warranties for warranty details. Note: A 2 1/8" deep octagon junction box is recommended for through circuit wiring applications. S5R, S7R & S10R SlimSurface LED Round 5", 7" and 10" Apertures SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 2 of 9 Compatibility (5" & 7" Round) Installs into standard J-box applications for 5" & 7" models: 3 1/2" round (plastic)4" square (plastic) Not compatible with S5R 4" octagonal (metal)4" square (metal) Not compatible with S5R Fire rated J-box Fire rated classification is per the ceiling and junction box ratings. Dimensions SlimSurface LED 5" downlight Ø 5 38"137 mm Ø 4 12"115 mm 5 8"16 mm Ø 5 38" 137 mm Ø 5 38"137 mm Ø 4 12"115 mm 5 8"16 mm Ø 5 38" 137 mm Ø 5 38"137 mm Ø 4 12"115 mm 5 8"16 mm Ø 5 38" 137 mm Ø 7 78" 201 mm Ø 7 78"201 mm Ø 7"179 mm 58"16 mm Ø 7 78" 201 mm Ø 7 78"201 mm Ø 7"179 mm 58"16 mm SlimSurface LED 10" downlight Ø 10 58" 269 mm Ø 10 58"269 mm Ø 9 5 8"244 mm 58"16 mm Ø 10 58" 269 mm Ø 10 58"269 mm Ø 9 5 8"244 mm 58"16 mm Ø 10 58" 269 mm Ø 10 58"269 mm Ø 9 5 8"244 mm 58"16 mm SlimSurface LED 7" downlight Ø 7 78" 201 mm Ø 7 78"201 mm Ø 7"179 mm 58"16 mm Compatibility (10" Round) Install into 4-11/16" J-box: 4 11/16" square (metal) Compatible with S10R only S5R, S7R & S10R SlimSurface LED Round 5", 7" and 10" Apertures SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 3 of 9 75 150 225 300 375 60° 30° Candela Curves 75 150 225 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 266 263 261 260 254 239 217 190 160 118 81 55 40 30 23 18 11 4 0 25 736 110 118 91 51 31 18 5 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 208326469522 39.8%62.5%89.7%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676359 119107968678716459545047 119103907970635751474340 119100857364575146423835 116105948476706458545046 11698847364575146413835 111100908274686257534945 11195827263565045413834 10697877972666056514844 10692807062565045413734 10088776760534843393633 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 117543 6.0'7.2'8.4'9.6'10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 21.814.210.28.56.8 0.400.260.190.160.13 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R927K7 • 10 W LED, 90 CRI, 2700 K 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2. Wattage: controlled to within 5% 3. Correlated Color Temperature: within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 150 300 450 600 750 60° 30° Candela Curves 150 300 45050 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 496 490 479 464 433 391 348 309 265 197 135 92 68 51 40 30 21 9 0 46 130 180 193 152 85 52 32 10 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 356549786880 40.5%62.4%89.3%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676359 119107968678716559555147 119103907970635752474340 119100857465575146423835 116104948577706459545047 11698847364575146423835 111100908274686257534946 11195827263565146423835 10696877972666156524845 10692807162565045413835 10088776760534843393633 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 20141086 5.5'6.6'7.7'8.8'9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 21.814.210.28.56.8 2.891.901.351.130.90 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R927K10 • 14 W LED, 90 CRI, 2700 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1053GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 523 lms 1.2 87° 9.1 W Efficacy: CCT3: CRI: 57.4 lm/w 2700 K 90 min Report1: 962GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 880 lms 1.1 83° 13.5 W Efficacy: CCT3: CRI: 65.2 lm/w 2700 K 90 min S5R, S7R & S10R SlimSurface LED Round 5", 7" and 10" Apertures SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 4 of 9 75 150 225 300 375 60° 30° Candela Curves 75 150 225 Angle Mean CP Lumens 051015202530354045505560657075808590 2942912892882812652412111781319162453426201340 28 81 121 131 102 57 34 21 5 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 231 362 521 581 39.7% 62.3% 89.6% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 64 59 54 50 47 119 103 90 79 70 63 57 51 47 43 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 105 94 84 76 70 64 58 54 50 46 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 106 97 87 79 72 66 60 56 51 48 44 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 12 8 6 5 4 6.0' 7.2' 8.4' 9.6' 10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 24.2 15.8 11.3 9.5 7.5 2.77 1.82 1.30 1.08 0.87 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R827K7 • 10 W LED, 80 CRI, 2700 K 150 300 450 600 750 60° 30° Candela Curves 150 300 450 60600 Angle Mean CP Lumens 051015202530354045505560657075808590 6256186045845464944403903372501701178565513927120 59 164 227 244 193 108 65 41 13 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 449 693 994 1113 40.4% 62.3% 89.3% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 65 59 55 51 47 119 103 90 79 70 63 57 52 47 43 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 25 17 13 10 8 5.5' 6.6' 7.7' 8.8' 9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 24.2 15.8 11.3 9.5 7.5 3.68 2.42 1.73 1.44 1.15 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R827K10 • 14 W LED, 80 CRI, 2700 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1054GFR Output lumens:Spacing Criterion:Beam Angle:Input Watts2: 581 lms1.287°9.3 W Efficacy:CCT3: CRI: 62.5 lm/w2700 K80 min Report1: 964GFR Output lumens:Spacing Criterion:Beam Angle:Input Watts2: 1113 lms1.183°13.4 W Efficacy:CCT3: CRI: 83.1 lm/w2700 K80 min S5R, S7R & S10R SlimSurface LED Round 5", 7" and 10" Apertures SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 5 of 9 75 150 225 300 375 60° 30° Candela Curves 75 150 225 300300 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 31931531331330629026423119714610069503829221560 30 88 131 142 109 62 37 22 6 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 249391562628 39.7%62.3%89.6%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676359 119107968678716459545047 1191039079706357514743 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 98 84 73 64 57 51 46 41 38 35 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 106 97 87 79 72 66 60 56 51 48 44 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 139754 6.0'7.2'8.4'9.6'10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 26.217.112.210.28.1 3.062.011.431.190.96 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R830K7 • 10 W LED, 80 CRI, 3000 K 150 300 450 600 750 60° 30° Candela Curves 150 300 450 6 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 6076015885685314804273793282431651138363493726120 57 159 221 237 187 105 63 39 13 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 4376749661081 40.4%62.3%89.4%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676359 119107968678716559555147 1191039079706357524743 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 24171297 5.5'6.6'7.7'8.8'9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 26.217.112.210.28.1 3.552.331.661.391.11 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R830K10 • 14 W LED , 80 CRI, 3000 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1055GFR Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 628 lms 1.287°9.1 W Efficacy:CCT3: CRI: 69.0 lm/w3000 K80 min Report1: 961GFR Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 1081 lms 1.183°13.5 W Efficacy:CCT3: CRI: 80.0 lm/w3000 K80 min S5R, S7R & S10R SlimSurface LED Round 5", 7" and 10" Apertures SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 6 of 9 75 150 225 300 375 60° 30° Candela Curves 75 150 225 300 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 34734434134033231228324820915410774534131231550 33 96 143 155 119 68 41 25 7 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 272426613685 39.6%62.2%89.5%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676359 119107968678716459545047 1191039079706357514743 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 98 84 73 64 57 51 46 41 38 35 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 111 95 82 72 63 56 50 45 41 38 34 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 1410754 6.0'7.2'8.4'9.6'10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 28.618.713.311.28.9 3.342.191.561.301.04 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R835K7 • 10 W LED, 80 CRI, 3500 K 150 300 450 600 750 60° 30° Candela Curves 150 300 450 600600 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 6396326185975585054493993452551741208867524028120 60 167 232 249 197 111 67 42 13 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 45970810161139 40.3%62.2%89.2%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676359 119107968678716559555147 1191039079706357524743 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 261813108 5.5'6.6'7.7'8.8'9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 28.618.713.311.28.9 3.742.451.751.461.17 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R835K10 • 14 W LED, 80 CRI, 3500 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1056GFR Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 685 lms 1.287°9.1 W Efficacy:CCT3: CRI: 75.3 lm/w3500 K80 min Report1: 965GFR Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 1139 lms 1.183°13.5 W Efficacy:CCT3: CRI: 84.4 lm/w3500 K80 min S5R, S7R & S10R SlimSurface LED Round 5", 7" and 10" Apertures SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 7 of 9 75 150 225 300 375 60° 30° Candela Curves 75 150 225 300 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 36636336035935032929926222116311379574434251660 35 101 151 163 126 72 44 27 7 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 286450648726 39.5%62.0%89.3%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676359 119107968678716459545047 1191039079706357514743 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 98 84 73 64 57 51 46 41 38 35 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 106 97 87 79 72 66 60 56 51 48 44 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 1510765 6.0'7.2'8.4'9.6'10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 30.319.814.111.89.4 3.542.321.661.381.10 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R840K7 • 10 W LED, 80 CRI, 4000 K 150 300 450 600 750 60° 30° Candela Curves 150 300 450 600 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 7107026866636205604994433822831931339774574430140 66 186 258 276 218 122 74 46 15 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 51078611271262 40.4%62.3%89.3%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676359 119107968678716559555147 1191039079706357524743 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 282014119 5.5'6.6'7.7'8.8'9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 30.319.814.111.89.4 4.172.741.961.631.30 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R840K10 • 14 W LED, 90 CRI, 2700 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1057GFR Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 726 lms 1.287°9.1 W Efficacy:CCT3: CRI: 79.8 lm/w4000 K80 min Report1: 963GFR Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 1262 lms 1.183°13.4 W Efficacy:CCT3: CRI: 94.2 lm/w4000 K80 min S5R, S7R & S10R SlimSurface LED Round 5", 7" and 10" Apertures SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 8 of 9 200 400 600 800 1000 60° 30° Candela Curves 200 400 600 800 1000 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 102710171008992947871776685597459313223161122937046200 97 279 399 429 351 204 122 74 23 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 775120317581977 39.2%60.9%88.9%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671666259 119107958677706459545047 1191039079706256514643 39 119 100 85 73 64 56 50 45 41 37 34 116 104 93 84 76 69 63 58 53 49 46 116 98 84 72 63 56 50 45 41 37 34 111 100 90 81 74 67 61 57 52 48 45 111 95 82 71 63 56 50 45 41 37 34 106 96 87 79 71 65 60 55 51 47 44 106 92 80 70 62 55 49 45 41 37 34 100 88 76 67 59 53 47 43 39 35 32 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 4129211613 5.5'6.6'7.7'8.8'9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 83.454.839.132.626.1 1.040.680.490.410.33 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S10R830K22 • 24 W LED, 80 CRI, 3000 K 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2. Wattage: controlled to within 5% 3. Correlated Color Temperature: within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. Report1: S10R927K22BK Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 1977 lms 1.187°23.5 W Efficacy:CCT3: CRI: 84.1 lm/w3000 K80 min 60° 30° 200 400 600 800 1000 Candela Curves 200 400 600 800 10001000 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 1000990981966922847754664579442300212153117896744200 94 271 388 416 339 195 117 71 22 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 754117017031913 39.4%61.2%89.0%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111029588827671676259 119107958677706459545047 1191039079706256514743 39 119 100 85 73 64 57 51 45 41 38 35 116 104 94 84 76 69 63 58 54 50 46 116 98 84 72 64 56 50 45 41 38 34 111 100 90 81 74 67 62 57 52 49 45 111 95 82 71 63 56 50 45 41 37 34 106 96 87 79 72 65 60 55 51 48 44 106 92 80 70 62 55 50 45 41 37 34 100 88 76 67 59 53 47 43 39 35 32 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 4028201612 5.5'6.6'7.7'8.8'9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 80.853.037.931.625.2 1.060.700.500.410.33 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S10R835K22 • 24 W LED, 80 CRI, 3500 K Report1: 963GFR Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 1913 lms 1.187°23.9 W Efficacy:CCT3: CRI: 80.0 lm/w3500 K80 min © 2019 Signify Holding. All rights reserved. This document may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. All trademarks are owned by Signify Holding or their respective owners. Signify North America Corporation 200 Franklin Square Drive, Somerset, NJ 08873 Telephone 855-486-2216 Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3 Telephone 800-668-9008 www.lightolier.com S5R, S7R & S10R SlimSurface LED Round 5", 7" and 10" Apertures SlimSurface-5in-7in-10in-Round-S5R-S7R-S10R 11/18 page 9 of 9 160 320 480 640 800 60° 30° Candela Curves 160 320 480 640 Angle Mean CP Lumens 0 5 1015202530354045505560657075808590 79478878176973266959552545334423816211687664932130 75 216 307 328 265 149 87 52 15 Zonal lumens & percentages Zone Lumens %Luminaire 0-300-400-600-90 59892513391493 40.0%62.0%89.7%100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio012345678910 1191111039588827671676359 119107968678716559555147 1191039079706357514743 40 119 100 85 74 64 57 51 46 42 38 35 116 105 94 85 77 70 64 58 54 50 46 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 50 45 41 38 35 106 97 87 79 72 66 60 56 52 48 45 106 93 80 70 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5'6'7'8'9' 3222161210 5.5'6.6'7.7'8.8'9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5'6'7'8'9' 63.341.529.724.719.8 1.010.660.470.390.32 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S10R927K22 • 23 W LED, 90 CRI, 2700 K Report1: S10R927K22BK Output lumens: Spacing Criterion: Beam Angle:Input Watts2: 1493 lms 1.186°22.8 W Efficacy:CCT3: CRI: 65.5 lm/w2700 K90 min 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2. Wattage: controlled to within 5% 3. Correlated Color Temperature: within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products.