Loading...
HomeMy WebLinkAboutSD-20-02 - Supplemental - 0010 Mansfield View Lane (24) 575 Dorset Street South Burlington, VT 05403 tel 802.846.4106 fax 802.846.4101 www.sburl.com Permit Number SD-______-__________ (office use only) APPLICATION FOR SUBDIVISION PLAT REVIEW □ Preliminary □ Final PUD Being Requested? □ Yes □ No All information requested on this application must be completed in full. Failure to provide the requested information either on this application form or on the plans will result in your application being rejected and a delay in the review before the Development Review Board. 1. OWNER(S) OF RECORD (Name(s) as shown on deed, mailing address, phone) ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ 2. LOCATION OF LAST RECORDED DEED (Book and page #) ___________________________________________ 3. APPLICANT (Name, mailing address, phone) _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ 4. CONTACT PERSON (Name, mailing address, phone) _______________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ a. Contact email address: ________________________________________________________________ 5. PROJECT STREET ADDRESS: __________________________________________________________________ 2 Subdivision Application Form. Rev. 5-2018 6. TAX PARCEL ID # (can be obtained at Assessor’s Office) ___________________________________________ 7. PROJECT DESCRIPTION a. General Project Description (describe what you are proposing): __________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ b. Existing Uses on Property (including description and size of each separate use): ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ c. Proposed Uses on property (include description and size of each new use and existing uses to remain): ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ d. Total building square footage on property (proposed buildings and existing buildings to remain): ___________________________________________________________________________________________ ___________________________________________________________________________________________ e. Height of building & number of floors (proposed buildings and existing buildings to remain, specify if basement and mezzanine): _________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ f. Number of residential units (if applicable, new units and existing units to remain): ___________________________________________________________________________________________ ___________________________________________________________________________________________ g. Number of employees (existing and proposed, note office versus non-office employees): ___________________________________________________________________________________________ ___________________________________________________________________________________________ 3 Subdivision Application Form. Rev. 5-2018 h. Other (list any other information pertinent to this application not specifically requested above, please note if Overlay Districts are applicable): ________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ i. List any changes to the subdivision, such as property lines, number of units, lot mergers, etc. ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ 8. LOT COVERAGE (ALL information MUST be provided here, even if no change is proposed) a. Size of Parcel: ___________________________ (acres /sq. ft.) b. Building Coverage: Existing __________ square feet __________ % Proposed _________ square feet __________ % c. Overall Coverage (building, parking, outside storage, etc): Existing __________ square feet __________ % Proposed _________ square feet __________ % d. Front Yard Coverage(s) (commercial projects only): Existing __________ square feet __________ % Proposed _________ square feet __________ % 9. WETLAND INFORMATION a. Are there any wetlands (Class I, II, or III) on the subject property? □ Yes □ No b. If yes, is the proposed development encroaching into any of these wetlands associated 50’ buffers (describe) _____________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ 4 Subdivision Application Form. Rev. 5-2018 c. If yes, please submit the following with this application: 1. A site specific wetland delineation of the entire property or a written statement that the applicant is relying on the City’s wetland map. 2. Response to the criteria outlined in Section 12.02(E) of the Land Development Regulations (applicant is strongly encouraged to have a wetland expert respond to these criteria) 10. AREA DISTURBED DURING CONSTRUCTION: ___________________SQ. FT. * *Projects disturbing more than one (1) acre of land must follow the City’s specifications for erosion control in Article 16 of the Land Development Regulations. Projects disturbing more than one (1) acre require a permit from the Vermont Department of Environmental Conservation. 11. COST ESTIMATES a. New Building or Addition, including initial fit-up. (If fit-up not available, contact Planning & Zoning staff) $____________________ b. Landscaping: $____________________ (Please submit itemized list of landscaping proposed) c. Other site improvements (please list with cost) __________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ 12. ESTIMATED TRAFFIC a. P.M. Peak hour for entire property (In and out): ___________________________________ 13. PEAK HOURS OF OPERATION: ____________________________________________ 14. PEAK DAYS OF OPERATION: ______________________________________________ 15. ESTIMATED PROJECT COMPLETION DATE: _______________________________ 16. PLANS AND FEE Plat plans shall be submitted which shows the information required by the City’s Land Development Regulations. Three (3) regular size copies, one reduced copy (11" x 17"), and one digital (PDF-format) copy of the plans must be submitted. A subdivision application fee shall be paid to the City at the time of submitting the application. See the City fee schedule for details. 5 Subdivision Application Form. Rev. 5-2018 NOTE: NOTIFICATION of ADJOINING PROPERTY OWNERS: Notification of adjoining property owners, in accordance with 24 V.S.A. §4464(a) and Section 17.06(B) of the South Burlington Land Development Regulations, is the responsibility of the applicant. After deeming an application complete, the Administrative Officer will provide the applicant with a draft meeting agendas or public hearing notice and sample certificate of service. The sworn certificate of service shall be returned to the City prior to the start of any public hearing. I hereby certify that all the information requested as part of this application has been submitted and is accurate to the best of my knowledge. ________________________________________ SIGNATURE OF APPLICANT _________________________________________________________________________ SIGNATURE OF PROPERTY OWNER PRINT NAME ___________________________________________________________________________ Do not write below this line DATE OF SUBMISSION:__________________________________ I have reviewed this preliminary plat application and find it to be:  Complete  Incomplete _______________________________________________________ Administrative Officer Date The applicant or permittee retains the obligation to identify, apply for, and obtain relevant state permits for this project. Call (802) 879-5676 to speak with the regional Permit Specialist. CEA Properties, LLC Adjoiner List 10 Mansfield View Lane – Tax Map Parcel 1095-00010 DATE: April 2019 1/2 Parcel ID # 0860-01100 Owner of Record East Mountain View, LLC Property Location: 1100 Hinesburg Rd 1100 Hinesburg Rd, Suite 201 South Burlington, VT 05403 Parcel ID # 1438-00068 Owner of Record HRG Office Building, LLC Property Location: 68 Randall St. 302 Mountain View Dr., Suite 300 Colchester, VT 05446 Parcel ID # 1438-00072 Owner of Record SBRC Properties, LLC Property Location: 72 Randall St. 85 Shunpike Rd. Williston, VT 05495 Parcel ID # 1155-00284 Owner of Record SBRC Properties, LLC Property Location: 284 Meadowland Dr. 85 Shunpike Rd. Williston, VT 05495 Parcel ID # 0860-00175 Owner of Record City of South Burlington Property Location: 1175 Hinesburg Rd 575 Dorset St. South Burlington, VT 05403 Parcel ID # 0860-01075 Owner of Record Rye Associates Property Location: 1075 Hinesburg Rd 21 Carmichael St., Suite 201 Essex Jct., VT 05452 CEA Properties, LLC Adjoiner List 10 Mansfield View Lane – Tax Map Parcel 1095-00010 DATE: April 2019 2/2 Parcel ID # 0860-01160 Owner of Record So. Burlington Realty Company, LLC Property Location: 1160 Hinesburg Rd 85 Shunpike Rd. Williston, VT 05495 Plan Sheet Listing P1 Subdivision Plat C0.0 Cover Sheet C1.0 Overall Site Plan C1.1 Existing Conditions C2.0 Site Improvements Plan C2.1 Site Grading & Drainage Plan C2.2 Site Utility Plan C2.3 Site Lighting Plan SE-2.0 Site Lighting Plan –(2007 Final Approval) C3.0 Preconstruction EPSC Site Plan C3.1 EPSC Final Stabilization Site Plan C3.2 EPSC Narrative C3.3 EPSC Narrative & Details C3.4 EPSC Details C4.0 Site Details C4.1 Utility Details C4.2 Misc. Details C5.0 Specifications C5.1 Specifications C5.2 Specifications C5.3 Specifications C5.4 Specifications C5.5 Specifications C6.3 Specifications C6.4 Specifications C6.5 Specifications A1.0 Building Elevations A2.0 Building Floor Plan L Site Landscaping Plan Page 1 of 8 Lot 1A –CEA Campus Planned Unit Development Preliminary Plat & Final Plat Application Submittal Requirements (1)Items (1)through (9) in Section 15.05(A) (1) Name and address of the owner of record and applicant.This information is depicted on the Drawing Border. (2) Name of owners of record of contiguous properties.This is depicted on the Plat plan and the general site plans. (3)Date, true north arrow and scale (numerical and graphic). The preferred scale shall be not more than one hundred (100) feet to the inch, or not more than sixty (60) feet to the inch where lots have less than one hundred (100) feet of frontage.True north is oriented up on all plans and all of the plans are at a scale of 1” = 30’. (4) Location map, showing relation of proposed subdivision to adjacent property and surrounding area.A location map showing the site at a scale of 1” = 2000’ is shown on the plans. (5) Boundaries and area of:This information is depicted on the Plat Plan Sheet P-1. (a) All contiguous land belonging to owner of record, (b) The proposed subdivision,This application seeks to create footprint lots in support of subsequent financing requirements for the individual buildings..and (c) Existing zoning districts (boundaries only).This property is located entirely within and bounded by the IO District. (6) Existing and proposed layout of property lines; type and location of existing and proposed restrictions on land, such as easements and covenants.Outside of the proposed footprint lots, there are no proposed boundary line modifications. The project does propose the relocation of the emergency access easement originally favoring Monson Properties. This project also benefits from a new easement from South Burlington Realty to enable access to the existing gravity sewer system on Lot 1B. (7) Type of, location, and size of existing and proposed streets, structures, utilities, and open space.This information is depicted on the Site Utility Plan Sheet C2.2. (8) Existing water courses, wetlands, floodplains, wooded areas, ledge outcrops, and other natural features.This information is depicted on the Existing Condition Plan Sheet C1.0 and C1.1. (9) Location of existing septic systems and wells.There are none as all of the properties in the area are served by municipal water and sewer. (2)For applications including commercial or industrial uses or multifamily dwellings,or applications made as a PUD This project does propose additional office space within Page 2 of 8 the IO Distract which requires that the project be reviewed as a PUD in addition to the fact that multiple principle buildings are proposed on the same parent parcel.all information required for site plan review in Section 14.05 (D)of these Regulations as outlined below. (1)Legal data: (a)A list of the owners of record of abutting properties,which may be generated by the Department of Planning and Zoning or by the applicant.A list of abutting and cross street owners is attached with this application package. (b)Boundaries of existing zoning and special districts on the subject property and adjacent zoning and special district boundaries.This information is depicted on the Plat Plan Sheet P-1.This parcel is not subject to the Hinesburg Road North View Protection Zone nor the Airport Approach Cone. (c)Area and boundaries of the property,building or setback lines as required in this chapter,and lines of existing streets and adjoining lots,as shown on a survey.This information is depicted on the Plat Plan Sheet P-1. (d)Streams,drainage ways,and associated stream buffer areas as set forth in Article 12.This information is depicted on the Existing Condition Plan Sheet C1.0 and C1.1. (e)Reservations,easements and areas dedicated to public use,if known,shall beshown.This information is depicted on the Plat Plan Sheet P-1. (f)Lot dimensions and survey data,and section and lot numbers of the subject property.This information is depicted on the Plat Plan Sheet P-1. (2)General project description: (a)The title of the development,date,North arrow,scale,name and address of the owner of record and of the applicant,if other than the owner,and of the engineer, architect,landscape architect or surveyor preparing the plan shall be shown on a preliminary site plan map.This information is shown on the border of each plan sheet.Where the applicant or owner is a corporation,the Development Review Board may require the names and addresses of all officers,directors and principal stockholders of said corporation.The preferred scale shall be not less than one (1)inch equals thirty (30)feet.The site plan has been developed at a scale of 1” = 30’. (b)Such map shall show the applicant’s entire property,adjacent properties, streets within two hundred (200)feet of the site,approximate location and dimensions of all existing structures,and location of all existing structures on adjacent properties and within one hundred (100)feet of the site boundary. At the discretion of the Administrative Officer or Development Review Board,the required area of the site plan may be increased.This information is depicted on the Plat Plan Sheet P-1. (c)Such map shall show proposed structures,access points,and general internal circulation.Sheet C2.0 shows the proposed improvements associated with the project. Page 3 of 8 (d)Existing and proposed contours at a maximum vertical interval of two (2)feet. One foot contours are depicted on the existing condition and grading plans. (3)Existing conditions: (a)Location of existing structures on the site The existing CEA Office building and accessory garage are shown on the plans.and showing all site conditions to remain. This information is depicted on the Existing Condition Plan Sheet C1.1 and the proposed grading plan on Sheet C2.2. (b)Location of watercourses,waterbodies,wetlands,floodplains,and floodplain boundaries as determined by the Federal Emergency Management Agency or as mapped by the City of South Burlington,watercourses,wetlands,rock outcrops, wooded areas,existing vegetation,and other significant natural features on the site. This information is depicted on the Existing Condition Plan Sheet C1.1. (c)Topographic contours and profiles as needed.This information is depicted on the proposed grading plan,Sheet C2.1. The shared access drive follows the existing grade without excessive slope and as such a profile is not included.The proposed water main profile shows this condition on Sheet C2.2 (d)Existing structures and access points on adjacent properties,including those directly across a public street.A large overview of the property is provided on Sheet C1.0. (4)Development data: (a)All means of vehicular access and egress to and from the site onto public streets, and all provisions for pedestrian access and circulation.The existing office building shares a portion of the common drive with EMV, LLC .This common drive intersects with Hinesburg Road across from Fox Run. The proposed access to the two proposed buildings is reconfigured from that originally approved in 2007 so as to provide improved intersection turning movements. The driveway proposed to serve the two new buildings is 20-feet wide and has multiple horizontal curves in support of maximizing traffic calming in the area. A speed table is located at the far eastern end as a final traffic calming feature and to facilitate a pedestrian crossing. (b)One set of preliminary plans,elevations,floor plans,and sections of proposed structures showing the proposed location,use,design and height of all structures, roads,parking areas,access points,sidewalks and other walkways,loading docks, outdoor storage areas,sewage disposal areas,landscaping,screening,site grading,and recreation areas if required.Plans shall also show any proposed division of buildings into units of separate occupancy and location of drives and access thereto.The proposed westerly building is one tall story in height. Building elevations and its floor plans are attached for reference.The proposed westerly building will be similar to the existing building and elevations for that building are also included in the application. Page 4 of 8 (c)The location and layout of any off-street parking or loading areas,traffic circulation areas,pedestrian walkways,and fire lanes.The Site Improvement plans do depict on Sheet C2.0 the proposed parking layout and entry points to the buildings. (d)Analysis of traffic impacts,if required by the traffic overlay district and/or the DRB.The traffic study completed for this project is included with this application package. (e)Lot area in square feet and acres,and lot coverage calculations including building,overall,and front yard coverage.This information is included on the submitted application form. (f)The location of all proposed waterlines,valves and hydrants and sewer lines or of alternative means of water supply and sewage disposal and treatment.This information is depicted on the Site Utility Plan, sheet C2.2. (g)Cut sheets for all proposed outdoor lighting within the site.The proposed exterior lighting fixtures located within the proposed parking lot and attached to the proposed buildings is attached with the application package. (h)Preliminary grading,drainage,landscaping and buffering plan in accordance with Article 13,Supplemental Regulations.The proposed grading for the site is depicted on Sheet C2.2. (i)The extent and amount of cut and fill for all disturbed areas,including before- and-after profiles and cross sections of typical development areas,parking lots and roads,The scope of the cut and fill for the project profile is moderate in order to create the plateau for each building,surrounding parking and circulation program. The excess cut material is being blended into areas surrounding the buildings and in the mini-park as a separation between the main area and the access drive.and including an erosion and sedimentation control plan,and proposed locations of sediment sink/setting pond and interceptor swales.The proposed EPSC plan is found on Sheet C3.0 and C3.1. (j)Proposed stormwater management system,including (as applicable) location, supporting design data and copies of computations used as a basis for the design capacities and performance of stormwater management facilities.The project impervious area is currently covered in the 4290-9010 permit issued for the Meadowland Business Park.Our experience with the property is that there are no suitable infiltrative options or potential on the property. During the summer months the groundwater depth is deeper and as such a proposed rain garden is proposed between the buildings as part of the supplemental stormwater management requirements set forth in Article 12 of the Land Development Regulations. Page 5 of 8 (k)Detailed specifications and locations of planting,landscaping,screening, and/or buffering materials.The proposed landscaping plan shows the parking lot and building area landscaping materials. (l)The location of all existing and proposed site improvements,including drains,culverts,retaining walls and fences.The site improvements for the project a generally shown on Sheet C2.0 while the drainage improvements are on Sheet C2.1. (m)The location of any outdoor storage for equipment and materials if any,and the location,type and design of all solid waste-related facilities,including dumpsters and recycling bins.The proposed enclosed dumpsters are depicted on the Site Improvements Plan, Sheet C2.0.The detail is shown on sheet C4.0. (n)Location and design of all energy distribution facilities,including electrical,gas, and solar energy.The proposed utility distribution is shown on Sheet C2.2. (o)Lines and dimensions of all property that is offered,or to be offered,for dedication for public use,with purpose indicated thereon,and of all property that is proposed to be served by deed covenant for the common use of the property owners of the development.There are no additional offers of dedication for public use on this property. (p)Estimated project construction schedule,phasing,and date of completion. The proposed schedule calls for construction to begin in the Late Spring of 2020 and be completed by Late Fall 2020. (q)Estimated cost of all site improvements.$225,000.See attached estimate of probable construction costs. (r)Estimated daily and peak hour traffic generation,and an estimate of traffic generation during the peak hour of the adjacent street traffic.The traffic study prepared for the project identifies the supplemental traffic to be generated by the proposed land uses associated with this project. (s)Finished grades of walls,pavements,and storm drains.The proposed Site Grading Plan, Sheet C2.1 shows this information. (t)Detailed plans of retaining walls,steps,ramps,paving,and drainage structures.The plan package includes supporting details (C4 series) and specifications (C5 series) addresses this requirement. (u)Estimate of all earthwork,including the quantity of any material to be imported to or removed from the site or a statement that no material is to be removed or imported.The amount of imported granular materials is estimated to be approximately 590 CY.As the goal is to create a balanced site, no material is proposed to be removed from the property. (v)Location and dimensions of all proposed water supply,sanitary sewerage, stormwater system,and other utility lines and equipment,including connections to existing facilities.The existing and proposed utilities are depicted on Sheet C2.2. Page 6 of 8 (w)Detailed landscaping plan,including type,size,and location of all materials used and plans for buffer screening and fencing in conformance with Article 13, Section 13.06, Landscaping,Screening,and Street Trees.The proposed landscaping plan showing the parking lot trees and building area plant materials is shown on the landscape designsheet. (x)Locations,types,and cut sheets for all exterior lighting.The proposed lighting distribution is shown on Sheet C2.3. (5)Other:Any other information or data that the Administrative Officer or Development Review Board shall require for a full assessment of the project pursuant to this article. (3)Plans and profiles showing existing and proposed elevations along center lines of all streets within the subdivision.There are no proposed streets nor is this a subdivision. The proposed grading on the common access drive is shown on the Grading plan Sheet C2.1. (4)Plans and profiles showing location of street pavements,curbs,gutters,sidewalks, manholes,catch basins and culverts.The proposed pavements surfaces for the access drive, parking lot, curbs and drainage improvements is shown on the Grading and Drainage Sheet C2.1. (5)Plans showing the location,size and invert elevations of existing and proposed sanitary sewers,storm water drains,and fire hydrants and location and size of water,gas,electricity and any other utilities or structures.The proposed Site Utility Plan, Sheet C2.2, shows this information. (6)Details of proposed connection with the existing sanitary sewage disposal system The proposed Site Utility Plan, Sheet C2.2, shows the proposed connection point to the existing sewer main.or adequate provision for on-site disposal of septic wastes. (7)Preliminary designs of any bridges or culverts which may be required.There are no required culverts or bridges for this project. (8)The location of temporary markers adequate to enable the Development Review Board to locate readily and appraise the basic layout in the field.Unless an existing street intersection is shown,the distance along a street from one corner of the property to the nearest existing street intersection shall be shown.The existing condition features provide adequate reconciliation of where the proposed conditions are to be located. (9)List of waivers the applicant desires from the requirements of these regulations. Setback waivers list is attached in the application package. (10)Base flood elevation data for proposed development that contains at least fifty (50) units or five (5) acres,if appropriate.The base flood elevation date does not extend on to oradjacent to this property. (11)A complete survey of the subdivision,prepared by a licensed land surveyor,showing the location,bearing and length of every street line,lot line and boundary line,and existing and proposed restrictions on the land,including but not limited to access ways and utility easements. Where applicable,this information shall be tied to reference points previously established by the City.The survey information is depicted on the Plat Plan Sheet P-1 Page 7 of 8 D.Final Plat Application. (1)Items (1)through (10) in Section 15.08 above Please see above. (2)For applications including commercial or industrial uses or multifamily dwellings,or applications made as a PUD,all information required for site plan review in Section 14.05 (D)of these Regulations.Please see above. (3)The length of all straight lines,the deflection angles,radii,length of curves and central angles of all curves tangent distance and tangent bearings for each street.There are no proposed streets, the perimeter boundary information is shown on Plat Plan Sheet P-1. (4)By proper designation on such plat,all public space for which offers of cession are made by the applicant and those spaces title to which is reserved by him.None are proposed. (5)The location of all open space to be dedicated to the City as well as all open space to be retained by the applicant or to be held in common private ownership.None is proposed. (6)Lots within the subdivision numbered in numerical order within blocks,and blocks lettered in alphabetical order.The proposed 911 building street address numbers have been added to the plan using the E-911 numbering system method. (7)The location of all the improvements and utilities,including the location of all utility poles,utility cabinets,sewage disposal systems,water supply systems,and all details and locations of the stormwater management system.These Utility Improvements are shown on Sheet C2.2. (8)Permanent reference monuments shown thus:"X"and lot corner markers shown thus: "O".A more conventional means of depicting the existing and proposed monument locations consistent with Land Surveying standards has been utilized on the Plan. (9)Construction drawings of all required improvements.The typical sections, profiles, details and specifications are included in the plan package. (10)Supporting Documents (a)Copies of proposed deeds,agreements or other documents showing the manner in which open space,including park and recreational areas,and school site areas are to be dedicated,reserved and maintained and a certificate from the City Attorney that these documents are satisfactory.The existing inter-lot Access Agreement between EMV, LLC and CEA Properties, LLC is attached. The Munson Properties Emergency Egress easement language is enclosed. (b)A copy of such covenants or deed restrictions as intended to cover all or part of the tract.The Condo Declaration for the CEA Campus is attached. (c)A prospectus describing the management organization if one is required.The Bylaws for the CEA Campus is attached. (d)In the case of a subdivision or development served by a privately owned and/or maintained street:The access agreement with EMV, LLC is attached. (i) A copy of all proposed deeds, agreements, or other documents which convey or Page 8 of 8 relate to the use of a privately owned street or right-of-way, and a certificate of the City Attorney that these documents are satisfactory.The access agreement with EMV, LLC is attached. This is an existing agreement filed in the land records. (ii) A completed contract between the land owner and the City regarding the number of lots or dwelling units to be served by the proposed right-of-way or private street and the responsibility for the roadway maintenance, along with a certificate from the City Attorney that the contract is satisfactory.This maintenance obligations are outlin din the EMV, LLC agreement and in the CEA Campus Declaration. (11)A complete survey of the subdivision,prepared by a licensed land surveyor,showing the location,bearing and length of every street line,lot line and boundary line,and existing and proposed restrictions on the land,including but not limited to access ways and utility easements. Where applicable,this information shall be tied to reference points previously established by the City.The survey information is depicted on the Plat Plan Sheet P-1. Page 1 of 5 Criteria for Review of PUDs, Subdivisions, Transect Zone Subdivisions, and Master PlansA.General Standards.In all zoning districts of the City, the DRB shall make findings offacton a PUD,subdivision Transect Zone subdivision, and/or Master Plan in keepingwith the standards for approval of subdivisions in Article 15 and/or site plans andconditional uses in Article 14 For PUD, subdivision and/or Master Plan applicationswithin the SEQ, IO and R1-Lakeshore districts, the DRB shall also make positivefindings with respect to the project’s compliance with the specific criteria in thissection.The general standards applicable to all PUDs, subdivisions, Transect Zonesubdivisions, and Master Plans are, except as noted below:1.Sufficient water supply and wastewater disposal capacity is available to meet theneeds of the project in conformance with applicable State and City requirements,as evidenced by a City water allocation, City wastewater allocation, and/orVermont Water and Wastewater Permit from the Department of EnvironmentalConservation.The City of South Burlington Water Department purchases its water from wholesaler Champlain Water District and as of this time there are no issues with water quantity. The proposed expansion will be served by proposed municipal water service connections.The project proposes to extend the existing municipal sewage collection system located within theproperty.The project currently enjoys the issuance of a State WW permitfor the water and sewer improvements and allocations fo the twobuildings.2.Sufficient grading and erosion controls will be utilized during construction andafter construction to prevent soil erosion and runoff from creating unhealthy ordangerous conditions on the subject property and adjacent properties. Inmaking this finding, the DRB may rely on evidence that the project will becovered under the General Permit for Construction issued by the VermontDepartment of Environmental Conservation.As the proposed area of disturbance is greater than 1-acre, the project will be subject to the requirements of the State of Vermont General Permit 3-9020 for stormwater runoff from construction sites.The attached plans depict theproposed EPSC measures and supporting narrative and details.3.The project incorporates access, circulation and traffic management strategiessufficient to prevent unreasonable congestion of adjacent roads. In making thisfinding the DRB may rely on the findings of a traffic study submitted by theapplicant, and the findings of any technical review by City staff or consultants.Based on the ITE Trip Generation Manual 10th edition, the existing 7,200 square foot office use (Land Use 710 –General Office Building) generates 79 weekday trips,11 AM peak (adjacent street) trips, and 11PM peak Page 2 of 5 (adjacent street) trips.Including both the existing 7,200 square footgeneral office use, the proposed 4,400 SF veterinary use and the proposed7,200-square foot office uses,for a total of 14,400 square feet of general office use and 4,400 SF veterinary use,this project is anticipated to generate 240 weekday trips, 40 AM peak (adjacent street) trips, and 42 PM peak (adjacent street) trips.The original traffic study approved for the project in 2007 has been updated to reflect current traffic levels on VT Route 116 and the reduced traffic generation levels. The results indicate no change to the original findings of no additional off0soite traffic improvements being required.4.The project’s design respects and will provide suitable protection to wetlands,streams, wildlife habitat as identified in the Open Space Strategy, and any uniquenatural features on the site. In making this finding the DRB shall utilize theprovisions of Article 12 of these Regulations related to wetlands and streambuffers, and may seek comment from the Natural Resources Committee withrespect to the project’s impact on natural resources.Neither the Comprehensive Plan mapping nor the enclosed ANR mapping includes any mapped wetlands, streams, or wildlife habitats in the project location.5.The project is designed to be visually compatible with the planned developmentpatterns in the area, as specified in the Comprehensive Plan and the purpose ofthe zoning district(s) in which it is located. For Transect Zone subdivisions, thisstandard shall apply only to the location of lot lines, streets and street types, andnatural resources identified in Article XII of these Regulations.The proposedbuilding coverage is 10%, which is less than district’s the maximumallowablebuilding coverage of 30%.The proposed lot coverage is 41%,which is less than the district’s maximum allowable lot coverage of 50%.The table on enclosed Sheet C1.1 demonstrates the project’s compliancewith the dimensional standards for the IO zoning district. The proposedproject meets the district’s goals of preserving the generally opencharacter of the district through the introduction of a minipark amongst the buildings. This park has been designed to integrate common elements and shade features into the property with retention of the view corridor to Mt. Mansfield.6.Open space areas on the site have been located in such a way as to maximizeopportunities for creating contiguous open spaces between adjoining parcelsand/or stream buffer areas. For Transect Zone subdivisions, this standard shallapply only to the location of natural resources identified in Article XII of theseRegulations and proposed open spaces to be dedicated to the City of SouthBurlington.Please see the narrative above as it relates to the creation f anactive use recreation open space area.The property is not located within astream buffer area. Page 3 of 5 7.The layout of a subdivision or PUD has been reviewed by the Fire Chief or hisdesignee to insure that adequate fire protection can be provided, with thestandards for approval including, but not be limited to, minimum distancebetween structures, street width, vehicular access from two directions wherepossible, looping of water lines, water flow and pressure, and number andlocation of hydrants. All aspects of fire protection systems shall be designed andinstalled in accordance with applicable codes in all areas served by municipalwater. This standard shall not apply to Transect Zone subdivisions.Plans have been submitted to the Fire Chief for review. The project layout remains similar to that approved in 2007 as it relates to circulation.8.Roads, recreation paths, stormwater facilities, sidewalks, landscaping, utilitylines and lighting have been designed in a manner that is compatible with theextension of such services and infrastructure to adjacent properties. ForTransect Zone subdivisions, this standard shall only apply to the location andtype of roads, recreation paths, and sidewalks.The project proposes toconstruct the segment of the future recreation path as it runs across the CEA property. The project also provide pedestrian connectivity in the east-west direction by extending the existing sidewalk system to the recreation path and to the eastern property line. The project also extends the vehicular access to the eastern edge of the property in support of the applicant’s requirement to enable emergency access from the former South Burlington Realty (AKA Munson Property). The interface is outfitted with an unlocked gate in accordance with the agreement with EMV, LLC to the north.All new utility services for the project will be underground.All of the proposed lighting has bene design to conform with the LDRdesign standards.9.Roads, utilities, sidewalks, recreation paths, and lighting are designed in amanner that is consistent with City utility and roadway plans and maintenancestandards, absent a specific agreement with the applicant related tomaintenance that has been approved by the City Council. For Transect Zonesubdivisions, this standard shall only apply to the location and type of roads,recreation paths, and sidewalks.This project does not propose any new public roads, utilities,or sidewalks. The project does proposed a new public recreation path segment with a supporting IOD. The private lighting system has been designed to comply with the LDR requirements.All proposed utilities will be located on private property.10.The project is consistent with the goals and objectives of the ComprehensivePlan for the affected district(s).a.Objective 60: Give priority to the conservation of contiguous andinterconnected open space areas within this quadrant outside of thoseareas [districts, zones] specifically designated for development.This Page 4 of 5 project is surrounded by approved commercial subdivisions wherethe existing open space is not contiguous to this lot. .b.Objective 61:Maintain opportunities for traditional and emerging formsof agriculture that complement and help sustain a growing city, andmaintain the productivity of South Burlington’s remaining agriculturallands.The project is located on an already developed lot containing an existing office use and is largely surrounded by adjacent,existing development.c.Enhance Dorset Street as the SEQ’s “main street” with traffic calmingtechniques, streetscape improvements, safe interconnected pedestrianpathways and crossings, and a roadway profile suited to its intended localtraffic function.The project is located on Hinesburg Road, not DorsetStreet; therefore, this item is not applicable.11.The project’s design incorporates strategies that minimize site disturbance andintegrate structures, landscaping, natural hydrologic functions, and othertechniques to generate less runoff from developed land and to infiltrate rainfallinto underlying soils and groundwater as close as possible to where it hits theground. For Transect Zone subdivisions, this standard shall apply only to thelocation of natural resources identified in Article XII of these Regulations.B.Industrial-Open Space District.A Master Plan and/or PUD in the Industrial-OpenSpace District shall comply with the following standards:1.Open space and development areas shall be located so as to maximize theaesthetic values of the property in keeping with the Comprehensive Plan goalof preserving and enhancing the open character, natural areas, and scenicviews of the Quadrant, while allowing carefully planned development.Theproposedmini-park has bene sited so as to be both centrally locatedwhile also taking advantage of the views to Mt. Mansfield to the east.2.Open space and any buffering shall be located in a manner that minimizesimpacts on adjacent residential uses, if any.With the exception of an existing residence to the southwest, all of the adjoining lots on the east side of Hinesburg Road are within the IO zoning district. An existing vegetative buffer is located between the existing office building and the aforementioned existing residential use located to the southwest of the proposed expansion.Vegetative screening is proposed between theproposed expansion and the existing, adjoining residential use.C.R1-Lakeshore District. A Master Plan shall be required for development of morethan ten (10) residential units in a five (5) year period in the R1-Lakeshore District.Development pursuant to a Master Plan shall be subject to the following Page 5 of 5 supplemental standards:This project is not located with the R1-LakeshoreDistrict; therefore, this item is not applicable.1.Gross residential density shall be allowed to be increased to seven (7)dwelling units per acre This project is not located with the R1- Lakeshore District; therefore, this item is not applicable.2.Dwelling units shall not exceed two and one-half (2 ½) stories inheight.This project is not located with the R1-Lakeshore District; therefore, this item is not applicable.3.The layout of the PUD conforms to the City’s Official Map with respectto the layout of roads and open spaces.This project is not locatedwith the R1-Lakeshore District; therefore, this item is notapplicable.4.The proposed PUD maximizes the lakeshore recreation and accessopportunities and the conservation of historic resources.This project is not located with the R1-Lakeshore District; therefore, this item is not applicable.5.The proposed PUD protects the visual integrity of the lakeshore.This project is not located with the R1-Lakeshore District; therefore, this item is not applicable.End of Section Map created using ANR's Natural Resources Atlas 1,327 221.2 CEA Properties, LLC Vermont Agency of Natural Resources 1,005 © Vermont Agency of Natural Resources 168.0 1: WGS_1984_Web_Mercator_Auxiliary_Sphere Feet168.00 NOTES LEGEND84.00 vermont.gov DISCLAIMER: This map is for general reference only. Data layers that appear on this map may or may not be accurate, current, or otherwise reliable. ANR and the State of Vermont make no representations of any kind, including but not limited to, the warranties of merchantability, or fitness for a particular use, nor are any such warranties to be implied with respect to the data on this map. January 3, 2019 THIS MAP IS NOT TO BE USED FOR NAVIGATION 1" = 84 1cm = 10Ft.Meters LUMINAIRE SCHEDULE Civil Engineering Associates 12/18/2019 Type Catalog Number Description Lamp Pole Height Notes Quantity A S5e 35-40L Kim Lighting 1SA- SAR5-P35-40L-4K-120-DB- A25-7 with pole-P/PRA16- 4188SA/DB-P Single arm Type 5 cutoff luminaire at 20' AFG mounting height 46w LED PicoPrism, 5352 lumens, 4000K 20'Controlled by photorectacle and timed off by programmed timer 1 B 2S3p35-40L Kim Lighting 2SB-SAR3-P35-40L-4K-120- DB-A25-7 with pole- P/PRA20-4188SA/DB-P Double arm Type 3 cutoff luminaire at 20' AFG mounting height 2 x 46w LED PicoPrism, 5200 lumens x 2, 4000K 20'Controlled by photorectacle and timed off by programmed timer 1 C S3p35-40L Kim Lighting 1SA- SAR3-P35-40L-4K-120-DB- A25-7 with pole-P/PRA20- 4188SA/DB-P Single arm Type 3 cutoff luminaire at 20' AFG mounting height 46w LED PicoPrism, 5200 lumens, 4000K 20'Controlled by photorectacle and timed off by programmed timer 2 D SL1 Kim Lighting SL1-18L-4K-UV Light bollard with cutoff optics at 371/2" light center and 42" overall height LED mid power LED replaceable modules 42" overall bollard height On/off controlled by programmed timer 7 E RL56 Halo RL560WH9930 LED module with H2750ICAT new construction housing Recessed LED soffit light 13.5w LED, 900 lumens, 90 CRI, 4000K 9' ceiling mounted at porches Exterior wet location rated 4 Control Notes: Hinesburg Road, So. Burlington, VT 1. Site lighting shall be activated by photocell and shall be turned off by programmable timer located inside building. 2. Provide occupancy sensor control for bollard lighting with 15 minute delay after motion is no longer detected. 3. Provide program scheduled on/off control for porch lighting with manual interior override control. | 1 | JOB NOTES TYPE APPROVALS SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 SPECIFICATIONS ORDERING CODE FEATURES Certifications ■ PicoPrism® technology1 ■ Full uplight cutoff ■ Available in 580nm 3000K, 4000K and 5000K standard CCT ■ Type 1, 2, 3, 4, 5, R, L standard distributions ■ 0-10V dimming drivers standard ■ IP66 certified Configuration EPA 1SA 1 Arm Side Mt.0.70 2SB 2 Arm Side Mt.1.40 2SL 2 Arm Side Mt.1.20 3ST 3 Arm Side Mt.1.90 3SY*3 Arm Side Mt.1.90 4SC 4 Arm Side Mt.2.50 1W Single Wall Mt.n/a HSF Horz. Slipfitter n/a * Available round poles only. EPA is for Fixture only Distribution SAR1 Type I SAR2 Type II SAR3 Type III SAR4 Type IV SAR5 Type V SARR Type R, Right SARL Type L, Left Drive Current P35 350mA PicoPrism P70 700mA PicoPrism Fixture NFO Option NFO Neighbor Friendly Optic* Fuse Options SF 120, 277, 347 Line Volts DF 208, 240, 480 Line Volts Electrical Module Source 40L 40 LEDs 46W for 350mA 93W for 700mA Color Temperature2 2K 580nm3 3K 3000K 4K 4000K 5K 5000K Controls Photocell Options A25-7 7-pin Photocell Receptacle A30 120V Button Photocell A31 208V Button Photocell A32 240V Button Photocell A33 277V Button Photocell A34 480V Button Photocell A35 347V Button Photocell Approx. Weight = 30 lbs. EPA .070 for 1SA. See configuration for Additional EPAs. *Photometry available for Type III/IV. All others, consult factory. 5"(127 mm) 171/8"(435 mm) 6"(152 mm) FRONT 12"(305.mm) 171/8"(435 mm) BOTTOM Arm cross-section 13/4"(45 mm) 41/4"(108 mm) TOP Mounting Options Side Arm Mount 3 3" O.D. Pole 3.5 3.5" O.D. Pole 4 4" O.D. Pole 5 5" O.D. Pole 6 6" O.D. Pole SQ Square Pole 3000K and warmer CCTs only VSF Vertical Slipfitter Mount for 2" pipe tenon, (2-3/8" O.D.) SVSF Vertical Slipfitter Mount square for 2" pipe tenon, (2-3/8" O.D.) Motion SCL-R Round Pole Mounted Occupancy Sensor up to 16' SCL-S Square Pole Mounted Occupancy Sensor up to 16' SCH-R Round Pole Mounted Occupancy Sensor 16' to 30' SCH-S Square Pole Mounted Occupancy Sensor 16' to 30' Wireless WIR-RMI-IO 120-480V, 1000’ range, wiSCAPE RF control system with on/off/dim, alerts, monitoring and metering capabilities Voltages 120 120V 208 208V 240 240V 277 277V 347 347V4 480 480V4 Fixture Finish BL Black DB Dark Bronze GT Graphite LG Light Gray PS Platinum Silver TT Titanium WH White CC Custom Color* *Consult Representative 1 2 3 4 5 6 7 US Patent No. D674,965 S. Other patents pending.For custom optics and color temperature configurations, contact factory. Turtle friendly. Maximum 500mA drive current for 2K Amber option.347V & 480V currents may be supplied with step-down transformer.350mA only.Not available with other sensor or wireless control options.Specify group and zone at time of order. See www.hubbelllighting.com/sitesync for more details. Order at least one SiteSync interface accessory SWUSB or SWTAB. Each option contains SiteSync License, GUI, and Bridge Node. For Pole Spec Select: http://www.kimlighting.com/products/arms_and_poles/ For Control Spec Select: http://trpssl.com/index.html Microsoft, Encarta, MSN, and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. SW7PR6,7 Site Sync with 7 pin PCR SWUSB†SiteSync Software on USB SWTAB†SiteSync Windows® Tablet SWBRG†SiteSync Wireless Bridge Node WIR-RME-L wiSCAPE 7-pin Module NXOFM-1R1D-UNV NX 7-pin Module Control Accessories † When ordering with SiteSync, one of the following interface options must be chosen and ordered separately. Each option contains the SiteSync License, GUI and Bridge Node. | 2 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Lumen Data Absolute Lumens for 350mA Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K 5228 5085 5070 4524 5200 4723 5218 5104 4000K 5362 5215 5200 4640 5333 4844 5352 5234 5000K 5423 5275 5259 4693 5394 4899 5413 5294 Absolute Lumens for 700mA Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K 8716 8670 8640 7664 8705 7945 8957 8554 4000K 8940 8892 8862 7860 8928 8148 9187 8773 5000K 9042 8994 8963 7950 9030 8241 9292 8874 B.U.G. Rating for 350mA (TM15) in Lumens where B = Backlight, U = Uplight, G = Glare Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 4000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 5000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 B.U.G. Rating for 700mA (TM15) in Lumens where B = Backlight, U = Uplight, G = Glare Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G2 B3 U0 G3 B3 U0 G3 4000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G3 B3 U0 G3 B3 U0 G3 5000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G3 B3 U0 G3 B3 U0 G3 Electrical Drive Current 350mA 700mA Volts - AC Amps - AC System Watts Volts - AC Amps - AC System Watts 120 0.38 46 120 0.78 93 208 0.22 46 208 0.45 93 240 0.19 46 240 0.39 93 277 0.17 46 277 0.34 93 347 0.13 46 347 0.27 93 480 0.10 46 480 0.19 93 LED performance and lumen output continues to improve at a rapid pace. Log onto www.kimlighting.com to download the most current photometric files from Kim Lighting’s IES File Library. For custom optics and color temperature configurations, contact factory. Spectroradiometric 3000K Average 4000K Average 5000K Average Color Rendering Index (CRI)≥75 ≥70 ≥65 Power Factor >.90 >.90 >.90 Projected Lumen Maintenance* mA 50,000 hrs 100,000 hrs 350 mA 96.67%94.48% 700 mA 92.51%87.87% *Still awaiting independent third party verification | 3 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Housing: ■Extruded low copper aluminum main body. ■Die-cast low copper aluminum electrical gear compartment. ■Stainless steel hardware. ■ Die cast wall separates the optical and electrical compartment acting as thermal barrier. ■Electrical gear compartment doors are fastened with two hinges and a latch made of stainless steel. ■ Silicone gaskets seal the compartments at the barrier surface. Optical Module: ■ PicoPrism® refractors (enclosed LED PCBs for IP66 rating) aimed toward the task and spreads horizontally to produce great uniformity. ■ Type I, II, III, IV, V, L (left), and R (right) standard distributions. Custom available. ■ 3000K, 4000K, 5000K standard CCT. Amber and custom available. ■ IP66 certified. ■ Die-cast, low copper aluminum heat sink modules provide thermal transfer at PCB level. ■ Anodized aluminum carrier plate and heat sink modules. Lens Frame: ■One-piece low copper aluminum alloy die-cast is secured to housing with two toolless latches. Neighbor Friendly Optic ■ Optional integrated Neighbor Friendly Optic on each LED module to completely control unwanted backlight. Most effective with Type III and IV distibutions. Electrical Characteristics: ■Pre-assembled, aluminum gear tray. ■120V through 480V @ 50/60Hz. ■Class 2, 350mA or 700mA ■Power Factor = >.90 ■National Electrical Code, ANSI/NFPA 70. ■10kV surge suppression. ■ Thermal shield thermal control. ■ -30c starting driver. ■ 0-10V dimming interface. ■ All electronic components are IP66 rated. ■Electronic components are UL and/or CSA recognized. ■ Standard programmable driver for variable drive current settings from 350mA to 700mA. Dimming: ■ 10% to 100% dimming by the use of standard 0-10V interface driver. ■To activate the dimming system, a wiring harness is supplied and attached to the DIM Port (DIM IN) on the thermal shield protection system. This port allows the 0-10V Interface to bypass the thermal shield and control the driver. ■ The thermal shield works in conjunction with the control system to assure that overheating will not harm the LEDs. ■The wiring harness is connected with the use of the Purple lead as the positive (+) and the Grey lead as the negative (-) to an available control signal (by others). Support Arm: ■ Speed Mount and a reinforcing plate are provided with wire strain relief. ■ Speed Mount is square or circular cut for specified pole size and shape. ■Die-cast, low copper aluminum support arm for direct pole mount. ■Die-cast aluminum tool-less entry splice access cover. ■ Terminal block is mounted in the arm cavity and accepts #14 to #8 wire sizes. ■ Prewired to electrical module with quick-disconnect plugs located inside the electrical compartment. ■Optional cast, low copper aluminum horizontal slip-fitter with adaptor plate to secure the luminaire to 1-1/4” to 2” IPS pipe size arms. ■ Optional cast aluminum wall mount plate assembly. Attaches to the wall over the junction box. Luminaire attaches to the wall plate with a square cut Speed Mount. Finish: ■ Fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) polyester powdercoat. ■Standard colors include (BL) Black, (DB) Dark Bronze, (GT) Graphite, (WH) White, (PS) Platinum Silver, (LG) Light Gray, (TT) Titanium, and (CC) Custom Color (Include RAL#). Fusing: SF for 120, 277 and 347 Line Volts DF for 208, 240 and 480 Line Volts. ■High temperature fuse holders factory installed inside the fixture housing. Fuse is included. Certifications and Listings: ■ UL 1598 Standard for wet locations for Luminaires. ■ UL 8750 Standard for Safety for Light Emitting Diode (LED) Equipment for use in Lighting Products. ■IP66 certified. ■ CSA C22.2#250.0 Luminaires. ■ ANSI C136.31-2010 3G Vibration tested and compliant. ■ IDA compliant. ■RoHS compliant. ■Meets Buy American provisions within ARRA. ■IDA approved, 3000K and warmer CCTs only. CAUTION: ■ Fixtures must be grounded in accordance with national, state and/or local electrical codes, Failure to do so may result in serious personal injury. WARRANTY: ■ For full warranty see http://www. hubbelllighting.com/resources/warranty SPECIFICATIONS FixtureHousing 30 mA Max Gray Dimming Lead (-) Standard Input Black (+) White (-)Green (GND) Purple Dimming Lead (+) | 4 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Kim Lighting reserves the right to change specifications without notice. CONTROLS Gray Wire0-10V Dimming Purple Wire0-10V Dimming Orange Wire10V CustomerDefinedRed WireLine Voltage Brown Wire10V CustomerDefined Black WireLine Voltage White WireNeutral Photocell Receptacle A25-7 Fully gasketed and wired 7-pin receptacle option. Easy access location above the electrical compartment. 7-pin construction allows for a user-defined interface and provides a controlled definition of operational performance. ANSI twist-lock control module by-others. Standard customer operation modes: 1. Traditional on/off photoelectric control. 2. 5-pin wireless photoelectric control for added dimming feature. 3. 7-pin wireless photoelectric control for dimming and additional I/O connections for customer use. Button Photocell A30 for 120V, A31 for 208V, A32 for 240V, A33 for 277V, A35 for 347V, A34 for 480V, Photocell is factory installed inside the housing with a fully gasketed sensor on the side wall. For multiple fixture mountings, one fixture is supplied with a photocell to operate the others. Wireless Controls wiSCAPE™ Hubbell Control Solution’s wiSCAPE™ wireless control modules allow an individual fixture to managed, monitored and measured. The modules communicate securely over a robust certified meshed radio signal. The wiSCAPE modules provide on/off/dim control, external device input, alerts and metering. WIR-RMI-IO wiSCAPE Internal Module, 120-480V, 1000ft range (LOS), 3 Digital Inputs/1 Analog Input, 2 Outputs. WIR-RME-L wiSCAPE External Module,120-480V, 1000ft range (LOS), Internal Photocell, 1 Digital Input, Compatible with the A-25-7H option SiteSync™1 SiteSync™ wireless control system for reduction in energy and maintenance cost while optimizing light quality 24/7. See ordering information or visit www.hubbelllighting.com/products/sitesync for more details. Pole Mounted Round Pole-Mounted Occupancy Sensor up to 16' SCL-R Round Pole-Mounted Occupancy Sensor up to 16’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCL-R44/2772/BL3 Square Pole-Mounted Occupancy Sensor up to 16' SCL-S Square Pole-Mounted Occupancy Sensor up to 16’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for square pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCL-L/2772/BL3 Round Pole-Mounted Occupancy Sensor 16’ to 30’ SCH-R Round Pole-Mounted Occupancy Sensor: 16' to 30’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCH-R44/2772/BL3 Square Pole-Mounted Occupancy Sensor 16’ to 30’ SCH-S Square Pole-Mounted Occupancy Sensor: 16 to 30’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCH-S/2772/BL3 SCP The SCP is a photo-control with motion sensing accessory thats mounts to the side of any new or existing 3”-5” round or square straight pole. The SCP enables any pole mounted luminaire in excess of 75 watts, to meet California Title 24 requirements with integral 20KV/10KA surge protection for added reliability and serviceability. For more detail: http://www.aal.net/products/sensor_control_ programmable 2Voltage, 3Color, 4Pole Diameter 1 PRECOMMISSIONED SITESYNC ORDERING INFORMATION: When ordering a fixture with the SiteSync lighting control option, additional information will be required to complete the order. The SiteSync Commissioning Form or alternate schedule information must be completed. This form includes Project location, Group information, and Operating schedules. For more detailed information please visit www.HubbellLighting.com/products/sitesync or contact Hubbell Lighting tech support at (800) 345-4928. SiteSync fixtures with occupancy sensor (SWPM) require the mounting height of the fixture for selection of the lens. Examples: SiteSync only : ALT3/P70/60L/3KUV/PS/US/SWP SiteSync with Motion Control: ALT3/P70/60L/3KUV/PS/US/SWPM-20F MOB ORDERING INFORMATION: When ordering a fixture with a dimming occupancy sensor option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. ALT3/P70/60L/3KUV/PS/US/MOB - 1 to 30 min - 33%or 50% - ?? / DBT High to Dim Delay Low Level Mounting Height (ft.) 2Voltage, 3Color, 4Pole Diameter 1 PRECOMMISSIONED SITESYNC ORDERING INFORMATION: When ordering a fixture with the SiteSync lighting control option, additional information will be required to complete the order. The SiteSync Commissioning Form or alternate schedule information must be completed. This form includes Project location, Group information, and Operating schedules. For more detailed information please visit www.HubbellLighting.com/products/sitesync or contact Hubbell Lighting tech support at (800) 345-4928. SiteSync fixtures with occupancy sensor (SWPM) require the mounting height of the fixture for selection of the lens. Examples: SiteSync only : ALT3/P70/60L/3KUV/PS/US/SWP SiteSync with Motion Control: ALT3/P70/60L/3KUV/PS/US/SWPM-20F MOB ORDERING INFORMATION: When ordering a fixture with a dimming occupancy sensor option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. ALT3/P70/60L/3KUV/PS/US/MOB - 1 to 30 min - 33%or 50% - ?? / DBT High to Dim Delay Low Level Mounting Height (ft.) | 5 | Kim Lighting reserves the right to change specifications without notice. SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Wall Mounting: ■Fixture mounts to 3" or 4" junction boxes by a cast aluminum adapter plate with fixture mounting bolts. NOTE: Junction box in wall must provide adequate fixture support. See NEC sections 370-13, 17 and 410-14, 16. Quick-disconnect plug and wiring are provided to allow field connections prior to fixture mounting. Horizontal Slipfitter Mount: ■ Replaces standard mounting arm with a slipfitter which allows fixture to be mounted to a horizontal pole davit-arm with 2" pipe-size mounting end (2 3/8" O.D.). Cast aluminum slipfitter with set screw for an up or down 5° adjustment lock. Bolts to housing from inside the electrical compartment using mounting holes for the standard support arm. Davit-arm must be field drilled at a set screw location to insure against fixture rotation. Finished to match fixture. Vertical Slipfitter Mount: ■ Allows fixture with standard support arm to be mounted to poles having a 2" pipe-size tenon (2 3/8" O.D. x 4 1/2" min. length). All mount- ing configurations can be used (1SA, 2SB, 2SL, 3ST, 3SY, 4SC). 4" square or round die-cast aluminum with flush cap, secured by four 3/8" stainless steel set point allen screws, finished to match fixture and arm. NOTE: 3SY only available on round slipfitter. Neighbor Friendly Optic ■ Integrated Neighbor Friendly Optic on each PicoEmitter™ module to completely control unwanted backlight. Most effective with Type III and IV distibutions. Tamper-Resistant Latch ■ Standard die-cast latch is provided with a captive 10-32 stainless steel flat socket-head screw to prevent unauthorized opening. NOTE: Required only for vandal protection in locationswhere fixtures can be reached by unauthorized persons. OPTIONS Vertical Slipfitter Mount by Kim Pole with 2" pipe-size tenon (by others) stainless steel set screws Round Square Cat. No. VSF-1SA VSF-2SB VSF-2SL VSF-3ST VSF-3SY VSF-4SC Cat. No. SVSF-1SA SVSF-2SB SVSF-2SL SVSF-3ST SVSF-4SC Mounting Configuration 1SA - single arm mount 2SB - 2 at 180° 2SL - 2 at 90° 3ST - 2 at 90° 3SY - 2 at 120° 4SC - 2 at 90° Davit-arm with 2" pipe-size fixture mount (by others) Horizontal Slipfitter Mount by Kim 11/16" 43/4" J-box Wall mount using adapter plate 3" or 4" J-box in wall (by others) | 1 | JOB NOTES TYPE APPROVALS SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 SPECIFICATIONS ORDERING CODE FEATURES Certifications ■ PicoPrism® technology1 ■ Full uplight cutoff ■ Available in 580nm 3000K, 4000K and 5000K standard CCT ■ Type 1, 2, 3, 4, 5, R, L standard distributions ■ 0-10V dimming drivers standard ■ IP66 certified Configuration EPA 1SA 1 Arm Side Mt.0.70 2SB 2 Arm Side Mt.1.40 2SL 2 Arm Side Mt.1.20 3ST 3 Arm Side Mt.1.90 3SY*3 Arm Side Mt.1.90 4SC 4 Arm Side Mt.2.50 1W Single Wall Mt.n/a HSF Horz. Slipfitter n/a * Available round poles only. EPA is for Fixture only Distribution SAR1 Type I SAR2 Type II SAR3 Type III SAR4 Type IV SAR5 Type V SARR Type R, Right SARL Type L, Left Drive Current P35 350mA PicoPrism P70 700mA PicoPrism Fixture NFO Option NFO Neighbor Friendly Optic* Fuse Options SF 120, 277, 347 Line Volts DF 208, 240, 480 Line Volts Electrical Module Source 40L 40 LEDs 46W for 350mA 93W for 700mA Color Temperature2 2K 580nm3 3K 3000K 4K 4000K 5K 5000K Controls Photocell Options A25-7 7-pin Photocell Receptacle A30 120V Button Photocell A31 208V Button Photocell A32 240V Button Photocell A33 277V Button Photocell A34 480V Button Photocell A35 347V Button Photocell Approx. Weight = 30 lbs. EPA .070 for 1SA. See configuration for Additional EPAs. *Photometry available for Type III/IV. All others, consult factory. 5"(127 mm) 171/8"(435 mm) 6"(152 mm) FRONT 12"(305.mm) 171/8"(435 mm) BOTTOM Arm cross-section 13/4"(45 mm) 41/4"(108 mm) TOP Mounting Options Side Arm Mount 3 3" O.D. Pole 3.5 3.5" O.D. Pole 4 4" O.D. Pole 5 5" O.D. Pole 6 6" O.D. Pole SQ Square Pole 3000K and warmer CCTs only VSF Vertical Slipfitter Mount for 2" pipe tenon, (2-3/8" O.D.) SVSF Vertical Slipfitter Mount square for 2" pipe tenon, (2-3/8" O.D.) Motion SCL-R Round Pole Mounted Occupancy Sensor up to 16' SCL-S Square Pole Mounted Occupancy Sensor up to 16' SCH-R Round Pole Mounted Occupancy Sensor 16' to 30' SCH-S Square Pole Mounted Occupancy Sensor 16' to 30' Wireless WIR-RMI-IO 120-480V, 1000’ range, wiSCAPE RF control system with on/off/dim, alerts, monitoring and metering capabilities Voltages 120 120V 208 208V 240 240V 277 277V 347 347V4 480 480V4 Fixture Finish BL Black DB Dark Bronze GT Graphite LG Light Gray PS Platinum Silver TT Titanium WH White CC Custom Color* *Consult Representative 1 2 3 4 5 6 7 US Patent No. D674,965 S. Other patents pending.For custom optics and color temperature configurations, contact factory. Turtle friendly. Maximum 500mA drive current for 2K Amber option.347V & 480V currents may be supplied with step-down transformer.350mA only.Not available with other sensor or wireless control options.Specify group and zone at time of order. See www.hubbelllighting.com/sitesync for more details. Order at least one SiteSync interface accessory SWUSB or SWTAB. Each option contains SiteSync License, GUI, and Bridge Node. For Pole Spec Select: http://www.kimlighting.com/products/arms_and_poles/ For Control Spec Select: http://trpssl.com/index.html Microsoft, Encarta, MSN, and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. SW7PR6,7 Site Sync with 7 pin PCR SWUSB†SiteSync Software on USB SWTAB†SiteSync Windows® Tablet SWBRG†SiteSync Wireless Bridge Node WIR-RME-L wiSCAPE 7-pin Module NXOFM-1R1D-UNV NX 7-pin Module Control Accessories † When ordering with SiteSync, one of the following interface options must be chosen and ordered separately. Each option contains the SiteSync License, GUI and Bridge Node. | 2 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Lumen Data Absolute Lumens for 350mA Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K 5228 5085 5070 4524 5200 4723 5218 5104 4000K 5362 5215 5200 4640 5333 4844 5352 5234 5000K 5423 5275 5259 4693 5394 4899 5413 5294 Absolute Lumens for 700mA Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K 8716 8670 8640 7664 8705 7945 8957 8554 4000K 8940 8892 8862 7860 8928 8148 9187 8773 5000K 9042 8994 8963 7950 9030 8241 9292 8874 B.U.G. Rating for 350mA (TM15) in Lumens where B = Backlight, U = Uplight, G = Glare Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 4000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 5000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 B.U.G. Rating for 700mA (TM15) in Lumens where B = Backlight, U = Uplight, G = Glare Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G2 B3 U0 G3 B3 U0 G3 4000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G3 B3 U0 G3 B3 U0 G3 5000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G3 B3 U0 G3 B3 U0 G3 Electrical Drive Current 350mA 700mA Volts - AC Amps - AC System Watts Volts - AC Amps - AC System Watts 120 0.38 46 120 0.78 93 208 0.22 46 208 0.45 93 240 0.19 46 240 0.39 93 277 0.17 46 277 0.34 93 347 0.13 46 347 0.27 93 480 0.10 46 480 0.19 93 LED performance and lumen output continues to improve at a rapid pace. Log onto www.kimlighting.com to download the most current photometric files from Kim Lighting’s IES File Library. For custom optics and color temperature configurations, contact factory. Spectroradiometric 3000K Average 4000K Average 5000K Average Color Rendering Index (CRI)≥75 ≥70 ≥65 Power Factor >.90 >.90 >.90 Projected Lumen Maintenance* mA 50,000 hrs 100,000 hrs 350 mA 96.67%94.48% 700 mA 92.51%87.87% *Still awaiting independent third party verification | 3 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Housing: ■Extruded low copper aluminum main body. ■Die-cast low copper aluminum electrical gear compartment. ■Stainless steel hardware. ■ Die cast wall separates the optical and electrical compartment acting as thermal barrier. ■Electrical gear compartment doors are fastened with two hinges and a latch made of stainless steel. ■ Silicone gaskets seal the compartments at the barrier surface. Optical Module: ■ PicoPrism® refractors (enclosed LED PCBs for IP66 rating) aimed toward the task and spreads horizontally to produce great uniformity. ■ Type I, II, III, IV, V, L (left), and R (right) standard distributions. Custom available. ■ 3000K, 4000K, 5000K standard CCT. Amber and custom available. ■ IP66 certified. ■ Die-cast, low copper aluminum heat sink modules provide thermal transfer at PCB level. ■ Anodized aluminum carrier plate and heat sink modules. Lens Frame: ■One-piece low copper aluminum alloy die-cast is secured to housing with two toolless latches. Neighbor Friendly Optic ■ Optional integrated Neighbor Friendly Optic on each LED module to completely control unwanted backlight. Most effective with Type III and IV distibutions. Electrical Characteristics: ■Pre-assembled, aluminum gear tray. ■120V through 480V @ 50/60Hz. ■Class 2, 350mA or 700mA ■Power Factor = >.90 ■National Electrical Code, ANSI/NFPA 70. ■10kV surge suppression. ■ Thermal shield thermal control. ■ -30c starting driver. ■ 0-10V dimming interface. ■ All electronic components are IP66 rated. ■Electronic components are UL and/or CSA recognized. ■ Standard programmable driver for variable drive current settings from 350mA to 700mA. Dimming: ■ 10% to 100% dimming by the use of standard 0-10V interface driver. ■To activate the dimming system, a wiring harness is supplied and attached to the DIM Port (DIM IN) on the thermal shield protection system. This port allows the 0-10V Interface to bypass the thermal shield and control the driver. ■ The thermal shield works in conjunction with the control system to assure that overheating will not harm the LEDs. ■The wiring harness is connected with the use of the Purple lead as the positive (+) and the Grey lead as the negative (-) to an available control signal (by others). Support Arm: ■ Speed Mount and a reinforcing plate are provided with wire strain relief. ■ Speed Mount is square or circular cut for specified pole size and shape. ■Die-cast, low copper aluminum support arm for direct pole mount. ■Die-cast aluminum tool-less entry splice access cover. ■ Terminal block is mounted in the arm cavity and accepts #14 to #8 wire sizes. ■ Prewired to electrical module with quick-disconnect plugs located inside the electrical compartment. ■Optional cast, low copper aluminum horizontal slip-fitter with adaptor plate to secure the luminaire to 1-1/4” to 2” IPS pipe size arms. ■ Optional cast aluminum wall mount plate assembly. Attaches to the wall over the junction box. Luminaire attaches to the wall plate with a square cut Speed Mount. Finish: ■ Fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) polyester powdercoat. ■Standard colors include (BL) Black, (DB) Dark Bronze, (GT) Graphite, (WH) White, (PS) Platinum Silver, (LG) Light Gray, (TT) Titanium, and (CC) Custom Color (Include RAL#). Fusing: SF for 120, 277 and 347 Line Volts DF for 208, 240 and 480 Line Volts. ■High temperature fuse holders factory installed inside the fixture housing. Fuse is included. Certifications and Listings: ■ UL 1598 Standard for wet locations for Luminaires. ■ UL 8750 Standard for Safety for Light Emitting Diode (LED) Equipment for use in Lighting Products. ■IP66 certified. ■ CSA C22.2#250.0 Luminaires. ■ ANSI C136.31-2010 3G Vibration tested and compliant. ■ IDA compliant. ■RoHS compliant. ■Meets Buy American provisions within ARRA. ■IDA approved, 3000K and warmer CCTs only. CAUTION: ■ Fixtures must be grounded in accordance with national, state and/or local electrical codes, Failure to do so may result in serious personal injury. WARRANTY: ■ For full warranty see http://www. hubbelllighting.com/resources/warranty SPECIFICATIONS FixtureHousing 30 mA Max Gray Dimming Lead (-) Standard Input Black (+) White (-)Green (GND) Purple Dimming Lead (+) | 4 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Kim Lighting reserves the right to change specifications without notice. CONTROLS Gray Wire0-10V Dimming Purple Wire0-10V Dimming Orange Wire10V CustomerDefinedRed WireLine Voltage Brown Wire10V CustomerDefined Black WireLine Voltage White WireNeutral Photocell Receptacle A25-7 Fully gasketed and wired 7-pin receptacle option. Easy access location above the electrical compartment. 7-pin construction allows for a user-defined interface and provides a controlled definition of operational performance. ANSI twist-lock control module by-others. Standard customer operation modes: 1. Traditional on/off photoelectric control. 2. 5-pin wireless photoelectric control for added dimming feature. 3. 7-pin wireless photoelectric control for dimming and additional I/O connections for customer use. Button Photocell A30 for 120V, A31 for 208V, A32 for 240V, A33 for 277V, A35 for 347V, A34 for 480V, Photocell is factory installed inside the housing with a fully gasketed sensor on the side wall. For multiple fixture mountings, one fixture is supplied with a photocell to operate the others. Wireless Controls wiSCAPE™ Hubbell Control Solution’s wiSCAPE™ wireless control modules allow an individual fixture to managed, monitored and measured. The modules communicate securely over a robust certified meshed radio signal. The wiSCAPE modules provide on/off/dim control, external device input, alerts and metering. WIR-RMI-IO wiSCAPE Internal Module, 120-480V, 1000ft range (LOS), 3 Digital Inputs/1 Analog Input, 2 Outputs. WIR-RME-L wiSCAPE External Module,120-480V, 1000ft range (LOS), Internal Photocell, 1 Digital Input, Compatible with the A-25-7H option SiteSync™1 SiteSync™ wireless control system for reduction in energy and maintenance cost while optimizing light quality 24/7. See ordering information or visit www.hubbelllighting.com/products/sitesync for more details. Pole Mounted Round Pole-Mounted Occupancy Sensor up to 16' SCL-R Round Pole-Mounted Occupancy Sensor up to 16’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCL-R44/2772/BL3 Square Pole-Mounted Occupancy Sensor up to 16' SCL-S Square Pole-Mounted Occupancy Sensor up to 16’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for square pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCL-L/2772/BL3 Round Pole-Mounted Occupancy Sensor 16’ to 30’ SCH-R Round Pole-Mounted Occupancy Sensor: 16' to 30’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCH-R44/2772/BL3 Square Pole-Mounted Occupancy Sensor 16’ to 30’ SCH-S Square Pole-Mounted Occupancy Sensor: 16 to 30’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCH-S/2772/BL3 SCP The SCP is a photo-control with motion sensing accessory thats mounts to the side of any new or existing 3”-5” round or square straight pole. The SCP enables any pole mounted luminaire in excess of 75 watts, to meet California Title 24 requirements with integral 20KV/10KA surge protection for added reliability and serviceability. For more detail: http://www.aal.net/products/sensor_control_ programmable 2Voltage, 3Color, 4Pole Diameter 1 PRECOMMISSIONED SITESYNC ORDERING INFORMATION: When ordering a fixture with the SiteSync lighting control option, additional information will be required to complete the order. The SiteSync Commissioning Form or alternate schedule information must be completed. This form includes Project location, Group information, and Operating schedules. For more detailed information please visit www.HubbellLighting.com/products/sitesync or contact Hubbell Lighting tech support at (800) 345-4928. SiteSync fixtures with occupancy sensor (SWPM) require the mounting height of the fixture for selection of the lens. Examples: SiteSync only : ALT3/P70/60L/3KUV/PS/US/SWP SiteSync with Motion Control: ALT3/P70/60L/3KUV/PS/US/SWPM-20F MOB ORDERING INFORMATION: When ordering a fixture with a dimming occupancy sensor option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. ALT3/P70/60L/3KUV/PS/US/MOB - 1 to 30 min - 33%or 50% - ?? / DBT High to Dim Delay Low Level Mounting Height (ft.) 2Voltage, 3Color, 4Pole Diameter 1 PRECOMMISSIONED SITESYNC ORDERING INFORMATION: When ordering a fixture with the SiteSync lighting control option, additional information will be required to complete the order. The SiteSync Commissioning Form or alternate schedule information must be completed. This form includes Project location, Group information, and Operating schedules. For more detailed information please visit www.HubbellLighting.com/products/sitesync or contact Hubbell Lighting tech support at (800) 345-4928. SiteSync fixtures with occupancy sensor (SWPM) require the mounting height of the fixture for selection of the lens. Examples: SiteSync only : ALT3/P70/60L/3KUV/PS/US/SWP SiteSync with Motion Control: ALT3/P70/60L/3KUV/PS/US/SWPM-20F MOB ORDERING INFORMATION: When ordering a fixture with a dimming occupancy sensor option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. ALT3/P70/60L/3KUV/PS/US/MOB - 1 to 30 min - 33%or 50% - ?? / DBT High to Dim Delay Low Level Mounting Height (ft.) | 5 | Kim Lighting reserves the right to change specifications without notice. SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Wall Mounting: ■Fixture mounts to 3" or 4" junction boxes by a cast aluminum adapter plate with fixture mounting bolts. NOTE: Junction box in wall must provide adequate fixture support. See NEC sections 370-13, 17 and 410-14, 16. Quick-disconnect plug and wiring are provided to allow field connections prior to fixture mounting. Horizontal Slipfitter Mount: ■ Replaces standard mounting arm with a slipfitter which allows fixture to be mounted to a horizontal pole davit-arm with 2" pipe-size mounting end (2 3/8" O.D.). Cast aluminum slipfitter with set screw for an up or down 5° adjustment lock. Bolts to housing from inside the electrical compartment using mounting holes for the standard support arm. Davit-arm must be field drilled at a set screw location to insure against fixture rotation. Finished to match fixture. Vertical Slipfitter Mount: ■ Allows fixture with standard support arm to be mounted to poles having a 2" pipe-size tenon (2 3/8" O.D. x 4 1/2" min. length). All mount- ing configurations can be used (1SA, 2SB, 2SL, 3ST, 3SY, 4SC). 4" square or round die-cast aluminum with flush cap, secured by four 3/8" stainless steel set point allen screws, finished to match fixture and arm. NOTE: 3SY only available on round slipfitter. Neighbor Friendly Optic ■ Integrated Neighbor Friendly Optic on each PicoEmitter™ module to completely control unwanted backlight. Most effective with Type III and IV distibutions. Tamper-Resistant Latch ■ Standard die-cast latch is provided with a captive 10-32 stainless steel flat socket-head screw to prevent unauthorized opening. NOTE: Required only for vandal protection in locationswhere fixtures can be reached by unauthorized persons. OPTIONS Vertical Slipfitter Mount by Kim Pole with 2" pipe-size tenon (by others) stainless steel set screws Round Square Cat. No. VSF-1SA VSF-2SB VSF-2SL VSF-3ST VSF-3SY VSF-4SC Cat. No. SVSF-1SA SVSF-2SB SVSF-2SL SVSF-3ST SVSF-4SC Mounting Configuration 1SA - single arm mount 2SB - 2 at 180° 2SL - 2 at 90° 3ST - 2 at 90° 3SY - 2 at 120° 4SC - 2 at 90° Davit-arm with 2" pipe-size fixture mount (by others) Horizontal Slipfitter Mount by Kim 11/16" 43/4" J-box Wall mount using adapter plate 3" or 4" J-box in wall (by others) | 1 | JOB NOTES TYPE APPROVALS SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 SPECIFICATIONS ORDERING CODE FEATURES Certifications ■ PicoPrism® technology1 ■ Full uplight cutoff ■ Available in 580nm 3000K, 4000K and 5000K standard CCT ■ Type 1, 2, 3, 4, 5, R, L standard distributions ■ 0-10V dimming drivers standard ■ IP66 certified Configuration EPA 1SA 1 Arm Side Mt.0.70 2SB 2 Arm Side Mt.1.40 2SL 2 Arm Side Mt.1.20 3ST 3 Arm Side Mt.1.90 3SY*3 Arm Side Mt.1.90 4SC 4 Arm Side Mt.2.50 1W Single Wall Mt.n/a HSF Horz. Slipfitter n/a * Available round poles only. EPA is for Fixture only Distribution SAR1 Type I SAR2 Type II SAR3 Type III SAR4 Type IV SAR5 Type V SARR Type R, Right SARL Type L, Left Drive Current P35 350mA PicoPrism P70 700mA PicoPrism Fixture NFO Option NFO Neighbor Friendly Optic* Fuse Options SF 120, 277, 347 Line Volts DF 208, 240, 480 Line Volts Electrical Module Source 40L 40 LEDs 46W for 350mA 93W for 700mA Color Temperature2 2K 580nm3 3K 3000K 4K 4000K 5K 5000K Controls Photocell Options A25-7 7-pin Photocell Receptacle A30 120V Button Photocell A31 208V Button Photocell A32 240V Button Photocell A33 277V Button Photocell A34 480V Button Photocell A35 347V Button Photocell Approx. Weight = 30 lbs. EPA .070 for 1SA. See configuration for Additional EPAs. *Photometry available for Type III/IV. All others, consult factory. 5"(127 mm) 171/8"(435 mm) 6"(152 mm) FRONT 12"(305.mm) 171/8"(435 mm) BOTTOM Arm cross-section 13/4"(45 mm) 41/4"(108 mm) TOP Mounting Options Side Arm Mount 3 3" O.D. Pole 3.5 3.5" O.D. Pole 4 4" O.D. Pole 5 5" O.D. Pole 6 6" O.D. Pole SQ Square Pole 3000K and warmer CCTs only VSF Vertical Slipfitter Mount for 2" pipe tenon, (2-3/8" O.D.) SVSF Vertical Slipfitter Mount square for 2" pipe tenon, (2-3/8" O.D.) Motion SCL-R Round Pole Mounted Occupancy Sensor up to 16' SCL-S Square Pole Mounted Occupancy Sensor up to 16' SCH-R Round Pole Mounted Occupancy Sensor 16' to 30' SCH-S Square Pole Mounted Occupancy Sensor 16' to 30' Wireless WIR-RMI-IO 120-480V, 1000’ range, wiSCAPE RF control system with on/off/dim, alerts, monitoring and metering capabilities Voltages 120 120V 208 208V 240 240V 277 277V 347 347V4 480 480V4 Fixture Finish BL Black DB Dark Bronze GT Graphite LG Light Gray PS Platinum Silver TT Titanium WH White CC Custom Color* *Consult Representative 1 2 3 4 5 6 7 US Patent No. D674,965 S. Other patents pending.For custom optics and color temperature configurations, contact factory. Turtle friendly. Maximum 500mA drive current for 2K Amber option.347V & 480V currents may be supplied with step-down transformer.350mA only.Not available with other sensor or wireless control options.Specify group and zone at time of order. See www.hubbelllighting.com/sitesync for more details. Order at least one SiteSync interface accessory SWUSB or SWTAB. Each option contains SiteSync License, GUI, and Bridge Node. For Pole Spec Select: http://www.kimlighting.com/products/arms_and_poles/ For Control Spec Select: http://trpssl.com/index.html Microsoft, Encarta, MSN, and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. SW7PR6,7 Site Sync with 7 pin PCR SWUSB†SiteSync Software on USB SWTAB†SiteSync Windows® Tablet SWBRG†SiteSync Wireless Bridge Node WIR-RME-L wiSCAPE 7-pin Module NXOFM-1R1D-UNV NX 7-pin Module Control Accessories † When ordering with SiteSync, one of the following interface options must be chosen and ordered separately. Each option contains the SiteSync License, GUI and Bridge Node. | 2 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Lumen Data Absolute Lumens for 350mA Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K 5228 5085 5070 4524 5200 4723 5218 5104 4000K 5362 5215 5200 4640 5333 4844 5352 5234 5000K 5423 5275 5259 4693 5394 4899 5413 5294 Absolute Lumens for 700mA Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K 8716 8670 8640 7664 8705 7945 8957 8554 4000K 8940 8892 8862 7860 8928 8148 9187 8773 5000K 9042 8994 8963 7950 9030 8241 9292 8874 B.U.G. Rating for 350mA (TM15) in Lumens where B = Backlight, U = Uplight, G = Glare Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 4000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 5000K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 B.U.G. Rating for 700mA (TM15) in Lumens where B = Backlight, U = Uplight, G = Glare Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G2 B3 U0 G3 B3 U0 G3 4000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G3 B3 U0 G3 B3 U0 G3 5000K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G3 B0 U0 G3 B3 U0 G3 B3 U0 G3 Electrical Drive Current 350mA 700mA Volts - AC Amps - AC System Watts Volts - AC Amps - AC System Watts 120 0.38 46 120 0.78 93 208 0.22 46 208 0.45 93 240 0.19 46 240 0.39 93 277 0.17 46 277 0.34 93 347 0.13 46 347 0.27 93 480 0.10 46 480 0.19 93 LED performance and lumen output continues to improve at a rapid pace. Log onto www.kimlighting.com to download the most current photometric files from Kim Lighting’s IES File Library. For custom optics and color temperature configurations, contact factory. Spectroradiometric 3000K Average 4000K Average 5000K Average Color Rendering Index (CRI)≥75 ≥70 ≥65 Power Factor >.90 >.90 >.90 Projected Lumen Maintenance* mA 50,000 hrs 100,000 hrs 350 mA 96.67%94.48% 700 mA 92.51%87.87% *Still awaiting independent third party verification | 3 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Housing: ■Extruded low copper aluminum main body. ■Die-cast low copper aluminum electrical gear compartment. ■Stainless steel hardware. ■ Die cast wall separates the optical and electrical compartment acting as thermal barrier. ■Electrical gear compartment doors are fastened with two hinges and a latch made of stainless steel. ■ Silicone gaskets seal the compartments at the barrier surface. Optical Module: ■ PicoPrism® refractors (enclosed LED PCBs for IP66 rating) aimed toward the task and spreads horizontally to produce great uniformity. ■ Type I, II, III, IV, V, L (left), and R (right) standard distributions. Custom available. ■ 3000K, 4000K, 5000K standard CCT. Amber and custom available. ■ IP66 certified. ■ Die-cast, low copper aluminum heat sink modules provide thermal transfer at PCB level. ■ Anodized aluminum carrier plate and heat sink modules. Lens Frame: ■One-piece low copper aluminum alloy die-cast is secured to housing with two toolless latches. Neighbor Friendly Optic ■ Optional integrated Neighbor Friendly Optic on each LED module to completely control unwanted backlight. Most effective with Type III and IV distibutions. Electrical Characteristics: ■Pre-assembled, aluminum gear tray. ■120V through 480V @ 50/60Hz. ■Class 2, 350mA or 700mA ■Power Factor = >.90 ■National Electrical Code, ANSI/NFPA 70. ■10kV surge suppression. ■ Thermal shield thermal control. ■ -30c starting driver. ■ 0-10V dimming interface. ■ All electronic components are IP66 rated. ■Electronic components are UL and/or CSA recognized. ■ Standard programmable driver for variable drive current settings from 350mA to 700mA. Dimming: ■ 10% to 100% dimming by the use of standard 0-10V interface driver. ■To activate the dimming system, a wiring harness is supplied and attached to the DIM Port (DIM IN) on the thermal shield protection system. This port allows the 0-10V Interface to bypass the thermal shield and control the driver. ■ The thermal shield works in conjunction with the control system to assure that overheating will not harm the LEDs. ■The wiring harness is connected with the use of the Purple lead as the positive (+) and the Grey lead as the negative (-) to an available control signal (by others). Support Arm: ■ Speed Mount and a reinforcing plate are provided with wire strain relief. ■ Speed Mount is square or circular cut for specified pole size and shape. ■Die-cast, low copper aluminum support arm for direct pole mount. ■Die-cast aluminum tool-less entry splice access cover. ■ Terminal block is mounted in the arm cavity and accepts #14 to #8 wire sizes. ■ Prewired to electrical module with quick-disconnect plugs located inside the electrical compartment. ■Optional cast, low copper aluminum horizontal slip-fitter with adaptor plate to secure the luminaire to 1-1/4” to 2” IPS pipe size arms. ■ Optional cast aluminum wall mount plate assembly. Attaches to the wall over the junction box. Luminaire attaches to the wall plate with a square cut Speed Mount. Finish: ■ Fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) polyester powdercoat. ■Standard colors include (BL) Black, (DB) Dark Bronze, (GT) Graphite, (WH) White, (PS) Platinum Silver, (LG) Light Gray, (TT) Titanium, and (CC) Custom Color (Include RAL#). Fusing: SF for 120, 277 and 347 Line Volts DF for 208, 240 and 480 Line Volts. ■High temperature fuse holders factory installed inside the fixture housing. Fuse is included. Certifications and Listings: ■ UL 1598 Standard for wet locations for Luminaires. ■ UL 8750 Standard for Safety for Light Emitting Diode (LED) Equipment for use in Lighting Products. ■IP66 certified. ■ CSA C22.2#250.0 Luminaires. ■ ANSI C136.31-2010 3G Vibration tested and compliant. ■ IDA compliant. ■RoHS compliant. ■Meets Buy American provisions within ARRA. ■IDA approved, 3000K and warmer CCTs only. CAUTION: ■ Fixtures must be grounded in accordance with national, state and/or local electrical codes, Failure to do so may result in serious personal injury. WARRANTY: ■ For full warranty see http://www. hubbelllighting.com/resources/warranty SPECIFICATIONS FixtureHousing 30 mA Max Gray Dimming Lead (-) Standard Input Black (+) White (-)Green (GND) Purple Dimming Lead (+) | 4 | SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf Kim Lighting reserves the right to change specifications without notice. © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Kim Lighting reserves the right to change specifications without notice. CONTROLS Gray Wire0-10V Dimming Purple Wire0-10V Dimming Orange Wire10V CustomerDefinedRed WireLine Voltage Brown Wire10V CustomerDefined Black WireLine Voltage White WireNeutral Photocell Receptacle A25-7 Fully gasketed and wired 7-pin receptacle option. Easy access location above the electrical compartment. 7-pin construction allows for a user-defined interface and provides a controlled definition of operational performance. ANSI twist-lock control module by-others. Standard customer operation modes: 1. Traditional on/off photoelectric control. 2. 5-pin wireless photoelectric control for added dimming feature. 3. 7-pin wireless photoelectric control for dimming and additional I/O connections for customer use. Button Photocell A30 for 120V, A31 for 208V, A32 for 240V, A33 for 277V, A35 for 347V, A34 for 480V, Photocell is factory installed inside the housing with a fully gasketed sensor on the side wall. For multiple fixture mountings, one fixture is supplied with a photocell to operate the others. Wireless Controls wiSCAPE™ Hubbell Control Solution’s wiSCAPE™ wireless control modules allow an individual fixture to managed, monitored and measured. The modules communicate securely over a robust certified meshed radio signal. The wiSCAPE modules provide on/off/dim control, external device input, alerts and metering. WIR-RMI-IO wiSCAPE Internal Module, 120-480V, 1000ft range (LOS), 3 Digital Inputs/1 Analog Input, 2 Outputs. WIR-RME-L wiSCAPE External Module,120-480V, 1000ft range (LOS), Internal Photocell, 1 Digital Input, Compatible with the A-25-7H option SiteSync™1 SiteSync™ wireless control system for reduction in energy and maintenance cost while optimizing light quality 24/7. See ordering information or visit www.hubbelllighting.com/products/sitesync for more details. Pole Mounted Round Pole-Mounted Occupancy Sensor up to 16' SCL-R Round Pole-Mounted Occupancy Sensor up to 16’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCL-R44/2772/BL3 Square Pole-Mounted Occupancy Sensor up to 16' SCL-S Square Pole-Mounted Occupancy Sensor up to 16’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for square pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCL-L/2772/BL3 Round Pole-Mounted Occupancy Sensor 16’ to 30’ SCH-R Round Pole-Mounted Occupancy Sensor: 16' to 30’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCH-R44/2772/BL3 Square Pole-Mounted Occupancy Sensor 16’ to 30’ SCH-S Square Pole-Mounted Occupancy Sensor: 16 to 30’ - an outdoor occupancy sensor with 0-10V interface dimming control that mounts directly to the pole. Wide 360° pattern. Module colors are available in Black, Gray, and White. Module is cut for round pole mounting. Pole diameter is needed upon order. Poles to be drilled in the field will be provided with installation instructions. Ordering Example: SCH-S/2772/BL3 SCP The SCP is a photo-control with motion sensing accessory thats mounts to the side of any new or existing 3”-5” round or square straight pole. The SCP enables any pole mounted luminaire in excess of 75 watts, to meet California Title 24 requirements with integral 20KV/10KA surge protection for added reliability and serviceability. For more detail: http://www.aal.net/products/sensor_control_ programmable 2Voltage, 3Color, 4Pole Diameter 1 PRECOMMISSIONED SITESYNC ORDERING INFORMATION: When ordering a fixture with the SiteSync lighting control option, additional information will be required to complete the order. The SiteSync Commissioning Form or alternate schedule information must be completed. This form includes Project location, Group information, and Operating schedules. For more detailed information please visit www.HubbellLighting.com/products/sitesync or contact Hubbell Lighting tech support at (800) 345-4928. SiteSync fixtures with occupancy sensor (SWPM) require the mounting height of the fixture for selection of the lens. Examples: SiteSync only : ALT3/P70/60L/3KUV/PS/US/SWP SiteSync with Motion Control: ALT3/P70/60L/3KUV/PS/US/SWPM-20F MOB ORDERING INFORMATION: When ordering a fixture with a dimming occupancy sensor option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. ALT3/P70/60L/3KUV/PS/US/MOB - 1 to 30 min - 33%or 50% - ?? / DBT High to Dim Delay Low Level Mounting Height (ft.) 2Voltage, 3Color, 4Pole Diameter 1 PRECOMMISSIONED SITESYNC ORDERING INFORMATION: When ordering a fixture with the SiteSync lighting control option, additional information will be required to complete the order. The SiteSync Commissioning Form or alternate schedule information must be completed. This form includes Project location, Group information, and Operating schedules. For more detailed information please visit www.HubbellLighting.com/products/sitesync or contact Hubbell Lighting tech support at (800) 345-4928. SiteSync fixtures with occupancy sensor (SWPM) require the mounting height of the fixture for selection of the lens. Examples: SiteSync only : ALT3/P70/60L/3KUV/PS/US/SWP SiteSync with Motion Control: ALT3/P70/60L/3KUV/PS/US/SWPM-20F MOB ORDERING INFORMATION: When ordering a fixture with a dimming occupancy sensor option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. ALT3/P70/60L/3KUV/PS/US/MOB - 1 to 30 min - 33%or 50% - ?? / DBT High to Dim Delay Low Level Mounting Height (ft.) | 5 | Kim Lighting reserves the right to change specifications without notice. SAR The Archetype® Small PicoPrism LED kl_sarpled_spec.pdf © 2017 KIM LIGHTING | 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev. Apr 23, 2019 Wall Mounting: ■Fixture mounts to 3" or 4" junction boxes by a cast aluminum adapter plate with fixture mounting bolts. NOTE: Junction box in wall must provide adequate fixture support. See NEC sections 370-13, 17 and 410-14, 16. Quick-disconnect plug and wiring are provided to allow field connections prior to fixture mounting. Horizontal Slipfitter Mount: ■ Replaces standard mounting arm with a slipfitter which allows fixture to be mounted to a horizontal pole davit-arm with 2" pipe-size mounting end (2 3/8" O.D.). Cast aluminum slipfitter with set screw for an up or down 5° adjustment lock. Bolts to housing from inside the electrical compartment using mounting holes for the standard support arm. Davit-arm must be field drilled at a set screw location to insure against fixture rotation. Finished to match fixture. Vertical Slipfitter Mount: ■ Allows fixture with standard support arm to be mounted to poles having a 2" pipe-size tenon (2 3/8" O.D. x 4 1/2" min. length). All mount- ing configurations can be used (1SA, 2SB, 2SL, 3ST, 3SY, 4SC). 4" square or round die-cast aluminum with flush cap, secured by four 3/8" stainless steel set point allen screws, finished to match fixture and arm. NOTE: 3SY only available on round slipfitter. Neighbor Friendly Optic ■ Integrated Neighbor Friendly Optic on each PicoEmitter™ module to completely control unwanted backlight. Most effective with Type III and IV distibutions. Tamper-Resistant Latch ■ Standard die-cast latch is provided with a captive 10-32 stainless steel flat socket-head screw to prevent unauthorized opening. NOTE: Required only for vandal protection in locationswhere fixtures can be reached by unauthorized persons. OPTIONS Vertical Slipfitter Mount by Kim Pole with 2" pipe-size tenon (by others) stainless steel set screws Round Square Cat. No. VSF-1SA VSF-2SB VSF-2SL VSF-3ST VSF-3SY VSF-4SC Cat. No. SVSF-1SA SVSF-2SB SVSF-2SL SVSF-3ST SVSF-4SC Mounting Configuration 1SA - single arm mount 2SB - 2 at 180° 2SL - 2 at 90° 3ST - 2 at 90° 3SY - 2 at 120° 4SC - 2 at 90° Davit-arm with 2" pipe-size fixture mount (by others) Horizontal Slipfitter Mount by Kim 11/16" 43/4" J-box Wall mount using adapter plate 3" or 4" J-box in wall (by others) 280LOW LEVEL Site Lightforms Bollard SL1 FIXTURE SL1 Site Lightforms FIXTURE FINISH BL Black DB Dark Bronze LG Light Gray TT Titanium PS Platinum Silver WH White CC Custom Color* *Consult representative 18L LEDs5 36L LEDs5 ELECTRICAL MODULE SL1 ORDERING. INFORMATION (Example) SL1 WH18L3K120 LED Color Temperature 2K Amber 3K 3000K 4K 4000K 5K 5000K FEATURES • SL1 is specifi cally designed and engineered to combine contemporary form with rugged cast aluminum vandal resistant construction • SL1 offers path lighting with IDA approved full-cutoff optics • One-piece extruded aluminum shaft for a clean sharp cornered appearance with superior strength • Battery back-up, emergency battery pack and houseside shield options SL1 SITE LIGHTFORMSMaximum weight: 37 lb SL2 SITE LIGHTFORMSMaximum weight: 47 lb FRONT SIDE FRONT SIDE 8"(203 mm)8E"(225 mm)8"(203 mm)3B"(79 mm) 42"*(1067 mm) 4K"(114 mm) BASE PLANSL1*36" OVERALL HEIGHTAVAILABLE - CONTACT KIM REPRESENTATIVE 8"(203 mm) 8K" (216 mm) BOLT CIRCLE DIA. 9D"(245 mm) 37K"(953 mm)LIGHTCENTERHEIGHT 42"*(1067 mm) 4K"(114 mm) BASE PLANSL2*36" OVERALL HEIGHTAVAILABLE - CONTACT KIM REPRESENTATIVE 8"(203 mm) 8K" (216 mm) BOLT CIRCLE DIA. 9D"(245 mm) 37K"(953 mm)LIGHTCENTERHEIGHT 21"(533 mm)8"(203 mm)8E"(225 mm) 3B"(80 mm) Voltages UV Universal Voltage(120 thru 277) 3000K and warmer CCTs only The Halo RL560 is a complete LED Baffle-Trim Module for 5" and 6" aperture recessed downlights; suitable for new construction, remodel and retrofit installation. The RL560 is cULus Listed for use with Halo and All-Pro, and is UL Classified for use with other compatible 5" and 6" housings. The RL560 with integral LED driver offers 120 volt dimming capability. The RL560 lens provides uniform illumination and wet location listing. Precision construction makes any housing AIR-TITE for added HVAC savings and code compliance. Compliant with NFPA 70, NEC section 410.16 (A)(1) and 410.16 (C)(3). RL560WH9† White MECHANICAL Module - Trim • Module construction includes LED, heat sink, reflector, lens, baffle and trim ring • Regressed baffle • Heat sink designed to conduct heat away from the LED keeping the junction temperatures below specified maximums, even when installed in insulated ceiling environments. L70 at 50,000 hours. • Designer trim finish options (sold separately) • White (Paintable) Trim Ring • Satin Nickel Trim Ring • Tuscan Bronze Trim Ring Lens • Regressed lens • Impact-resistant polycarbonate • Convex form for lamp-like appearance • High lumen transmission • Diffusing for even illumination Mounting • Integral torsion springs and Push-N-Twist clips offer two mounting options • Torsion springs are pre-installed and adjust to fit 5" or 6" compatible housings • Push-N-Twist universal installation clips are pre-installed and designed to fit 5" or 6" compatible housings Housing Compatibility See Housing Compatibility LED • Color Temperature (CCT)† Options: • 90 CRI: 2700K, 3000K, 3500K, 4000K, and 5000K • Can be used to comply with California Title 24 High Efficacy requirements. Certified to California Appliance Efficiency Database under JA8. LED Chromaticity • A tight chromaticity specification ensures LED color uniformity, sustainable Color Rendering Index (CRI) and Correlated Color Temperature (CCT) over the useful life of the LED • LED chromaticity of 3 SDCM exceeds ENERGY STAR® color stan-dards per ANSI C78.377-2008 • High color performance with R9 greater than 50 • Every Halo LED is quality tested, measured, and serialized in a permanent record to register lumens, wattage, CRI and CCT • Halo LED serialized testing and measurement ensures color and lumen consistency on a per-unit basis, and validates long-term product consistency over time ELECTRICAL Power Connections • LED connector is a non-screw base luminaire disconnect offering easy installation with the matching Halo 5" and 6" LED housings • LED Connector meets California Title-24 high efficacy luminaire requirement for a non-screw base socket, and where required to qualify as a high efficacy luminaire • The included E26 medium screw-base Edison adapter provides easy retrofit of incandescent housings (see Housing Compatibility) Ground Connection Separate grounding cable included on the module for attachment to the housing during installation. LED Driver • Dimmable driver is a 120 Volt, high efficiency, electronic power supply providing DC power to the LED • Driver meets FCC EMI/RFI Consumer Level limits for use in residential and commercial installations • Driver features high power factor, low THD, and has integral thermal protection in the event of over temperature or internal failure Dimming • Designed for continuous dimming capability to nominally 5% with many 120V Leading Edge (LE) and Trailing Edge (TE) Phase Control dimmers. (Dimmers with low end trim adjustment offer greater assurance of achieving 5% level.) • Consult dimmer manufacturer for compatibility and conditions of use Note: some dimmers require a neutral in the wallbox. Warranty Eaton provides a five year limited warranty on RL56 LED. Compliance Labels • UL Certified 1598 Luminaire with Halo housings and others - see Housing Compatibility • UL Certified for Damp Location • IP56 Ingress Protection rated • May be installed in housings in direct contact with insulation** and combustible material Compliance • Airtight certified per ASTM E283 (not exceeding 2.0 CFM under 75 Pascals pressure difference) • 90 CRI: Can be used to comply with California Title 24 High Efficacy requirements. Certified to California Title 20 Appliance Efficiency Database.* • 80 CRI: Can be used to comply with California Title 24 Non-Residential Lighting Controls requirements as an LED luminaire • Can be used for International Energy Conservation Code (IECC) high efficiency luminaire compliance • Can be used for Washington State Energy Code compliance • ENERGY STAR® Certified luminaire - consult ENERGY STAR® Certified Product List* • EMI/RFI per FCC 47CFR Part 15 Class B Consumer limits, suitable for use in residential and commercial installations • Contains no mercury or lead and RoHS compliant • Photometric testing in accordance with IES LM-79 • Lumen maintenance projections in accordance with IES LM-80 and TM-21 • Suitable for use in closets. Compliant with NFPA 70, NEC Sec. 410.16 (A)(1) and 410.16 (C)(3). Specification Features Description 900 Series 5/6-Inch LED Recessed Retrofit Module-Trim 90CRI 2700K, 3000K, 3500K, 4000K, 5000K FOR USE IN INSULATED CEILING AND NON- INSULATED CEILING RATED HOUSINGS HIGH EFFICACY LED WITH INTEGRAL DRIVER - DIMMABLE Refer to ENERGY STAR® Qualified Products List.Can be used to comply with California Title 24 High Efficacy requirements.Certified to California Appliance Efficiency Database under JA8. * Refer to ENERGY STAR® Certified Products List and CEC (T20) Appliance Database for listings. ** Not for use with housings in direct contact with spray foam insulation. † See ordering information table for available models. Catalog #Type Project Comments Date Prepared by HALO® TD518005EN October 23, 2017 3:55 PM Ordering Information Sample Number: RL560WH9927-RL56TRMSNB Complete unit includes a RL56 Baffle-Trim LED Module and a 5" and 6" compatible housing (ordered separately). Optional accessory designer trim ring ordered separately. RL56 900 Series Accessory (Order Separately) RL560WH9927=5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 2700K, Matte White RL560WH9930=5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 3000K, Matte White RL560WH9935=5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 3500K, Matte White RL560WH9940=5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 4000K, Matte White RL560WH9950=5"/6" Retrofit Baffle - Trim LED Module, 90CRI, 5000K, Matte White RL56TRMSNB=5/6" Satin Nickel Trim Ring, Baffle RL56TRMTBZB=5/6" Tuscan Bronze Trim Ring, Baffle RL56TRMWHB=5/6" White Paintable Trim Ring, Baffle RL56TRMSN=5/6" Satin Nickel Trim Ring RL56TRMTBZ=5/6" Tuscan Bronze Trim Ring RL56TRMWH=5/6" White Paintable Trim Ring OT400P=Oversize Flat White Metal Trim Ring 6" I.D. x 9-1/4" O.D. (ring slips behind RL56 ring, in stepped configuration) OT403P=Oversize White Plastic Trim Ring 6" I.D. x 8" O.D. (ring slips behind RL56 ring, in stepped configuration) TRM690WH=Oversize Matte White Metal Trim Ring. Designed for RL560 ring to inset into oversize ring for an even (non-stepped) trim surface HE26LED=Replacement screw base adapter (one included with unit) E26 Screw base adapter for retrofit (included) RL56 Dimensions Energy Data RL56 Series (Values at non-dimming line voltage) Minimum Starting Temp: -30°C (-22°F) EMI/RFI: FCC Title 47 CFR, Part 15, Class B (Consumer) Sound Rating: Class A Input Voltage: 120V Power Factor: >0.90 Input Frequency: 60Hz THD: <20% Input Power: 13.5W Input Current: 0.15A Maximum IC (Insulated Ceiling) Ambient Continuous Operating Temperature: 25°C (77°F) Maximum Non-IC Ambient Continuous Operating Temperature 40°C (104°F) Designer Trim Dimensions RL56TRMWHB White (Paintable) RL56TRMSNB Satin Nickel RL56TRMTBZB Tuscan Bronze 0.86"[21.8mm] 7.35"[186.7mm] 7.25” [184.15mm]2.33” [59.22mm] 7.35" [186.7mm] 0.86" [21.8mm] RL56TRMWH White (Paintable) RL56TRMSN Satin Nickel RL56TRMTBZ Tuscan Bronze page 2 RL56 LED System 900 Series Eaton1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting Specifications and dimensions subject to change without notice. RL56 Series LED Retrofit is UL Classified for retrofit in the follow 5/6" recessed housings: The RL Series LED light module - trim combination is UL Certified for use with any 5"/6" diameter recessed housing constructed of steel or aluminum with an internal volume that exceeds 107.9 in3 in addition to those noted above. Housing Compatibility Compatible Halo LED Housings with LED luminaire connector (high-efficacy compliant) HALO LED Recessed Can Size Catalog Number 5"H550ICAT, H550RICAT, E550ICAT, E550RICAT 6"H750ICAT, H750RICAT, H750T, H750RINTD010, H750TCP, H2750ICAT, H2750RICAT, E750ICAT, E750RICAT Halo LED Retrofit Enclosures HALO 6"ML7BXRFK, ML7E26RFK Compatible Halo Incandescent E26 Screwbase Housings HALO 5"H5ICAT, H5RICAT, H5ICATNB, H5T, H5RT, H25ICAT, H25ICATNB, E5TAT, E5RTAT, H5TNB, E5TATNB, E5ICAT, E5RICAT, E5ICATNB 6"H7ICAT, H7RICAT, H7ICT, H7RICT, H7ICATNB, H7ICTNB, H7T, H7RT, H7TNB, H7TCP, H7UICT, H7UICAT, H27ICAT, H27RICAT, H27T, H27RT, E7ICAT, E7RICAT, E27ICAT, E27RICAT, E7ICATNB, E7TAT, E7RTAT, E7TATNB, E27TAT, E27RTAT Product and Photometric Data RL56-900 Series Photometric* RL560WH9930 Luminaire lumens 930 Input watts 12.8 LER (LPW)72.7 Spacing Criteria 0-180 1.16 90-270 1.16 Diagonal 1.22 Beam angle (degrees)88.9 Field angle (degrees)140 Zonal lumen Lumens % Lumens 0-30 341 36.7 0-40 535 57.5 0-60 829 89.1 0-90 930 100 * Tested in accordance with IES LM63. Field results may vary. RL56 - 900 SERIES Cat No. CRI CCT Lumens Power (W)LPW RL560WH9927 92 2700 940 12.6 75 RL560WH9930 91 3000 930 12.8 73 RL560WH9935 92 3500 940 12.7 74 RL560WH9940 90 4000 1000 13.2 76 RL560WH9950 90 5000 1015 12.9 79 page 3 RL56 LED System 900 Series Eaton1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting Specifications and dimensions subject to change without notice. LIGHTING FACTS RL560WH99272700K Source RL560WH9950 5000K Source RL560WH99303000K Source RL560WH99353500K Source RL560WH99404000K Source Eaton1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting Specifications and dimensions subject to change without notice. page 4 RL56 LED System 900 Series ADV141506 6/17/2014 Catalog # Project Comments Prepared by Type Date HALO LED ICAT SHALLOW HOUSING for NEW CONSTRUCTION The H2750ICAT is a dedicated LED new construction housing for use in shallow ceilings where 2x6 joist construction is used.The H2750ICAT is designed to fit in shallow insulated ceilings and can be in direct contact with ceiling insulation*. This AIR-TITE housing design prevents airflow between conditioned and unconditioned spaces for savings on both heating and air conditioning costs. The LED connector system provides high efficacy code compliance when used with designated HALO LED modules and trims. Housings • Aluminum housing for greater heat dissipation. H2750ICAT housing is gasketed to prevent airflow from heated or air conditioned spaces Plaster Frame • Galvanized steel frame. Housing adjusts in plaster frame to accommodate up to 1-3/8” ceiling thickness. • Regressed locking screw for securing hanger bars. • Cutouts included for easily crimping hanger bars in position. Slide-N-Side™ Junction Box • Positioned to accommodate straight conduit runs. • Seven ½” trade size conduit knockouts with true pry-out slots. • Slide-N-Side wire traps allow non metallic sheathed cable to be installed without tools and without removing knockouts. • Allows wiring connections to be made outside the box. • Simply insert the cable directly into the trap after connections are made. • Accommodates the following standard non-metallic sheathed cable type: • U.S. #14/2, #14/3, #12/2, #12/3 • Canada: #14/2, #14/3, #12/2 GOT NAIL! Pass -N-Thru™ Bar Hangers Bar Hanger features include • Pre-installed nail easily installs in regular lumber, engineered lumber and laminated beams. • Safety and Guidance system prevents snagging, ensures smooth, straight nail penetration and allows bar hangers to be easily removed if necessary • Automatic leveling flange aligns the housing and allows holding the housing in place with one hand while driving nails. • Housing can be positioned at any point within 24” joist spans • Score lines allow tool-free shortening for 12” joists and bar hangers do not need to be removed for shortening. • Bar hangers may be repositioned 90° on plaster frame • IntegralT-bar clip snaps onto T-bars – no additional clips are required. LED Module Connection Halo shallow LED modules simply install with a plug-in 120V/277V rated line voltage wiring connector (UL and CSA Listed Luminaire Disconnect). This non-screw-base connection preserves the high efficacy rating and prevents use of low effi- cacy incandescent sources (see LED Module specifications). Caution LED connection is rated for 120V and 277V input. Installer must verify LED module voltage is compatible with the applicable voltage input. If uncertain, consult a qualified electrician. Labels • UL/cUL Listed 1598 Luminaire • CE Marking - “Conformité Européene” conformity with the Council of European Communities Directives, meeting internationally recognized compliance when used with ML56 Series LED modules • UL/cUL Listed for Feed Through • UL/cUL Listed for Damp Location • UL/cUL Listed forWet Location with select trims • UL/cUL Listed fro direct contact with insulation and combustible material* • Rated for 20W maximum Qualification May be used with qualified Halo LED modules and designated trims for High Efficacy Luminaire Compliance: • State of California Title 24 • International Energy Conservation Code (IECC) • Washington State Energy Code • New York State Energy Conservation Construction Code - AIR-TITE™ Compliant • Certified under ASTM-E283 standard for air-tight construction DESIGN FEATURES H2750ICAT 6” New Construction IC AIR-TITE™ Housing For Designated Halo LED Modules and Trims -RA56 Series -RL56 Series -ML56 Series High Efficacy LED Housing HALO® FOR USE IN INSULATED CEILINGS FOR DIRECT CONTACT WITH INSULATION* FOR USE IN SHALLOW CEILINGS 6-1/2"[165mm] 1/2"[13mm] 5"[127mm] 7-1/2"[191mm] 10-1/2"[267mm] * Not to be used in direct contact with spray foam insulation. Can be used with Qualified and compliant with select trims. Refer to ENERGY STAR® Qualified Products List and CEC (T24) Appliance Database for listings. Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com Specifications and dimensions subject to change without notice. Eaton’s Cooper Lighting Business 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.cooperlighting.com © 2014 EatonAll Rights ReservedPrinted in USAPublication No. ADV141506June 2014 H2750ICAT ORDERING INFORMATION - RL56 SERIES SAMPLE NUMBER: H2750ICAT - RL560WH6927 Order housing, light module, trim and separately. Housing RL56 Series - Compatible LED Retrofit Modules H2750ICAT= 6” Dedicated LED Insulated Ceiling, AIR-TITE New Construction Housing for Shallow Ceilings 80 CRI RL560WH6827= 5”/6” Retrofit Baffle - Trim LED Module, 80CRI, 2700K, Matte White RL560SN6827= 5”/6” Retrofit Baffle - Trim LED Module, 80CRI, 2700K, Satin Nickel RL560WH6830= 5”/6” Retrofit Baffle - Trim LED Module, 80CRI, 3000K, Matte White RL560SN6830= 5”/6” Retrofit Baffle - Trim LED Module, 80CRI, 3000K, Satin Nickel RL560WH6835= 5”/6” Retrofit Baffle - Trim LED Module, 80CRI, 3500K, Matte White 90 CRI RL560WH6927= 5”/6” Retrofit Baffle - Trim LED Module, 90CRI, 2700K, Matte WhiteRL560SN6927= 5”/6” Retrofit Baffle - Trim LED Module, 90CRI, 2700K, Satin NickelRL560WH6930= 5”/6” Retrofit Baffle - Trim LED Module, 90CRI, 3000K, Matte WhiteRL560SN6930= 5”/6” Retrofit Baffle - Trim LED Module, 90CRI, 3000K, Satin NickelRL560WH6935= 5”/6” Retrofit Baffle - Trim LED Module, 90CRI, 3500K, Matte White ORDERING INFORMATION - RA56 SERIES SAMPLE NUMBER: H2750ICAT - RA5606927WHOrder housing, light module, trim and separately. Housing RA56 Series - Compatible LED Retrofit Modules H2750ICAT= 6” Dedicated LED Insulated Ceiling, AIR-TITE New Construction Housing for Shallow Ceilings Very Wide Flood - VWFL Models RA5606927WH= 5”/6” LED Adjustable Gimbal, 90CRI, 2700K, White, Very Wide FloodRA5606930WH= 5”/6” LED Adjustable Gimbal, 90CRI, 3000K, White, Very Wide Flood Narrow Flood - NFL Models RA5606927NFLWH= 5”/6” LED Adjustable Gimbal, 90CRI, 2700K, White, Narrow FloodRA5606930NFLWH= 5”/6” LED Adjustable Gimbal, 90CRI, 3000K, White, Narrow Flood ORDERING INFORMATION - ML56 SERIES SAMPLE NUMBER: H2750ICAT - ML5606830 - 696WBOrder housing, light module, trim and separately. Housing ML56 LED Light Modules ML56 LED Trims ML56 System Accessories H2750ICAT= 6” Dedicated LED Insulated Ceiling, AIR-TITE New Construction Housing for Shallow Ceilings 600 Series / 80 CRIML5606827= 5"/6" LED Retrofit Downlight Light Module, 600 lumen, 80CRI, 2700KML5606830= 5"/6" LED Retrofit Downlight Light Module, 600 lumen, 80CRI, 3000KML5606835= 5"/6" LED Retrofit Downlight Light Module, 600 lumen, 80CRI, 3500KML5606840= 5"/6" LED Retrofit Downlight Light Module, 600 lumen, 80CRI, 4000K 600 Series / 90 CRIML5606927= 5”/6” LED Retrofit Downlight Light Module, 600 lumen, 90CRI, 2700KML5606930= 5”/6” LED Retrofit Downlight Light Module, 600 lumen, 90CRI, 3000KML5606935= 5”/6” LED Retrofit Downlight Light Module, 600 lumen, 90CRI, 3500KML5606940= 5”/6” LED Retrofit Downlight Light Module, 600 lumen, 90CRI, 4000K 900 Series / 80 CRIML5609827= 5”/6” LED Retrofit Downlight Light Module, 900 lumen, 80CRI, 2700KML5609830= 5”/6” LED Retrofit Downlight Light Module, 900 lumen, 80CRI, 3000KML5609835= 5”/6” LED Retrofit Downlight Light Module, 900 lumen, 80CRI, 3500KML5609840= 5”/6” LED Retrofit Downlight Light Module, 900 lumen, 80CRI, 4000K 900 Series / 90 CRIML5609927= 5”/6” LED Retrofit Downlight Light Module, 900 lumen, 90CRI, 2700KML5609930= 5”/6” LED Retrofit Downlight Light Module, 900 lumen, 90CRI, 3000KML5609935= 5”/6” LED Retrofit Downlight Light Module, 900 lumen, 90CRI, 3500KML5609940= 5”/6” LED Retrofit Downlight Light Module, 900 lumen, 90CRI, 4000K 1200 Series / 80 CRIML5612827= 5”/6” LED Light Module, 1200 lumen, 80CRI, 2700KML5612830= 5”/6” LED Light Module, 1200 lumen, 80CRI, 3000KML5612835= 5”/6” LED Light Module, 1200 lumen, 80CRI, 3500KML5612840= 5”/6” LED Light Module, 1200 lumen, 80CRI, 4000K 1200 Series / 90 CRIML5612927= 5”/6” LED Light Module, 1200 lumen, 90CRI, 2700KML5612930= 5”/6” LED Light Module, 1200 lumen, 90CRI, 3000KML5612935= 5”/6” LED Light Module, 1200 lumen, 90CRI, 3500KML5612940= 5”/6” LED Light Module, 1200 lumen, 90CRI, 4000K 690 Series - 6" LED Trims Non-Conductive “Dead Front” Baffles 691WB=6" LED Trim, Polymer “Dead- Front”, Shallow White Baffle & Flange (For use with 600 Series LED Light Modules only) Semi-Regressed Eyeballs 694WB=6" LED Directional Trim, White Eyeball, Baffle & Flange 694SNB=6" LED Directional Trim, Satin Nickel Eyeball, Baffle & Flange 694TBZB=6" LED Directional Trim, Tuscan Bronze Eyeball, Baffle & Flange Shallow Baffle 696WB=6" LED Trim, White Shallow Baffle & Flange ML56CLIP= 6” Friction Clip Kit - For use with non-torsion spring housings. 6” clips included. WW6955C= Wall Wash Insert - Specular Kick Reflector for 695WW (1 included with trim). For double wall washing or replacement. TRM690WH= 6" LED Oversize Trim Ring for use with 59* series trims, White 6.9" I.D., 9.5" O.D. Ring slips over LED trim. Inset design allows 6" trim to fit into oversize ring for an even trim surfaceEBA560PK= Replacement screwbase adapter to LED disconnect with cap ML56-1200 Series Beam Forming Optic MediaBFR56NFL=Beam forming reflector kit, narrow flood, 25° nominalBFR56MH=Media holder, accepts one 3.45” lens. Requires BFR56NFL & L345SF, order separately. L345SF=3.45” diameter soft focus lens. Requires BFR56NFL and BFR56MH, order separately. Solite® is a registered trademark of AGC Flat Glass North America. Approvals:Type:Job:Catalog number: Specifications Date:Page: 1 of 4 LED EmitterDeck® Electronic Module SAR-LED-KIT 40 Light Emitting Diodes 46 total System Watts for 350mA 93 total System Watts for 700mA Maximum Weight is 30 lbs. when installed in The Archetype LED SAR-LED-KIT The Archetype® Small PicoPrism™ LED Upgrade Kit 4/20/17 • kl_sarpledkit_spec.pdf / / LED Kit Electrical Module Option Electronic Module: All electrical components are UL and CSA recognized, mounted on a single plate and factory prewired with quick-disconnect plugs. Module includes a driver, thermal control device and surge protector. Electrical module attaches to housing with no-tool hinges and latches, accessible by opening the lens frame only. Driver is rated for -40°F starting. Optical Module: Precision, IP66 replaceable PicoPrism™ modules are positioned to achieve directional control toward desired task. The entire light engine fastens to the housing as a one-piece module Dimming: Driver has a 0-10V dimming interface with a dimming range of 10-100%. Approved dimmers include Lutron Diva AVTV, Lutron Nova NFTV and NTFTV. Note: Not compatible with current sourcing dimmers. Listed to: UL 1598 Standard for Luminaires - UL 8750 Standard for Safety for Light Emitting Diode (LED) Equipment for use in Lighting Products and CSA C22.2#250.0 Luminaires. RoHS compliant. Meets Buy American provisions within ARRA. Warranty: Kim Lighting warrants The Archetype LED products (“Product(s)”) sold by Kim Lighting to be free from defects in material and workmanship for (i) a period of five (5) years for metal parts, (ii) a period of ten (10) years for exterior housing paint finish(s), (iii) a period of six (6) years for LED Light Engines (PicoPrisms™ and, (iv) a period of five (5) years for LED power components (LED Driver, LifeShield® device), from the date of sale of such goods to the buyer as specified in Kim Lighting shipment documents for each product. Occupancy sensors, Surge Protector, dimmers and relay wiring components are covered by the manufacturer’s warranty. NOTE: Existing product conditions are taken as the base point. Participation rules apply. See complete warranty provisions for further details. IMPORTANT: Disable all power to the luminaire before conducting any maintenance or upgrade activity. Failure to do so will create a hazardous working environment. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes. Failure to do so may result in serious personal injury. KIM LIGHTING RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. © 2017 KIM LIGHTING • 16555 EAST GALE AVENUE, CITY OF INDUSTRY, CA 91745-1788 • TEL: 626/968-5666 • FAX: 626/968-5716 US Patent Number D674,965 S. Suggested Tools: • Phillips Screw Driver • Large Flat Blade Screw Driver WARNING: PicoPrism luminaires are designed with open door frame, no lens. When installing an Upgrade Kit, the glass lens must be removed due to the increased current of the Picoprism assemblies. Reference HID to PicoPrism Upgrade Kit Installation sheet for instructions. SAR-LED-KIT Page: 2 of 4 Type: Job: Standard Features Fixture Cat. No. designates fixture and distribution Upgrade Kit: SAR-LED-KIT Light Distribution: SAR-LED-KIT The Archetype® Small PicoPrism™ LED Upgrade Kit 4/20/17 • kl_sarpledkit_spec.pdf 40L xxK Electrical Module Cat. Nos. for Electrical Modules available: 1120V through 277V is a variable driver. Source: 40L = 40 LED’s Color Temperature:l 2K = 580nm - Amber l 3K = 3000K l 4K = 4200Kl 5K = 5100K Voltage:l 120 = 120V1l 208 = 208V1l 240 = 240V1l 277 = 277V1l 347 = 347Vl 480 = 480V Distribution:l 1 = Type I l 2 = Type II l 3 = Type III l 4 = Type IV l 5 = Type V l L = Type L l R = Type R x P xx Optic: P = PicoPrism™ Current: 35 = 350 mA 70 = 700 mA © 2017 KIM LIGHTING • 17760 ROWLAND STREET, CITY OF INDUSTRY, CA 91748 • TEL: 626/968-5666 • FAX: 626/369-2695 TYPE R One-Way Right TYPE LOne-Way Left TYPE IV TYPE V TYPE IIITYPE IITYPE I Page: 3 of 4 Type: Job: Optional Features SAR-LED-KIT The Archetype® Small PicoPrism™ LED Upgrade Kit 4/20/17 • kl_sarpledkit_spec.pdf Fusing Cat. No. (see right) l No Option High temperature fuse holders factory installed inside the fixture housing. Fuse included. Line Volts: 120V 208V 240V 277V 347V 480V Cat. No.: l SF l DF l DF l SF l SF l DF Single Fuse Neighbor Friendly Optic: Cat. No. l NFO l No Option Integrated Neighbor Friendly Optic on each PicoPrism™ module to completely control unwanted backlight. Most effective with Type III and IV distibutions. Driver has a 0-10V dimming interface with a dimming range of 10-100%. Approved dimmers include Lutron Diva AVTV, Lutron Nova NFTV and NTFTV. Note: Not compatible with current sourcing dimmers. 0-10V Dimming Interface Fixture Housing LifeShield® 40 mA Max Fixture Equivalent Circuit Dimming Lead (+) Dimming Lead (-) Driver 5V © 2017 KIM LIGHTING • 17760 ROWLAND STREET, CITY OF INDUSTRY, CA 91748 • TEL: 626/968-5666 • FAX: 626/369-2695 For warranty see http://www.hubbelllighting.com/resources/warranty Page: 4 of 4 Type: Job: SAR-LED-KIT The Archetype® Small PicoPrism™ LED Upgrade Kit 4/20/17 • kl_sarpledkit_spec.pdf Lumen Data © 2017 KIM LIGHTING • 17760 ROWLAND STREET, CITY OF INDUSTRY, CA 91748 • TEL: 626/968-5666 • FAX: 626/369-2695 Absolute Lumens for 350mA Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K 3747 3644 3634 3242 3727 3385 3740 3658 4200K 4536 4411 4378 3925 4512 4098 4527 4428 5100K 4930 4795 4730 4266 4904 4454 4921 4813 Absolute Lumens for 700mA Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K 6247 6214 6190 5493 6239 5694 6420 6131 4200K 7912 7870 7840 6956 7902 7211 8131 7765 5100K 8220 8176 8145 7227 8209 7492 8447 8067 B.U.G. Rating for 350mA (TM15) in Lumens where B = Backlight, U = Uplight, G = Glare Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K B2 U0 G2 B2 U0 G2 B1 U0 G1 B1 U0 G1 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 4200K B3 U0 G3 B2 U0 G2 B1 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 5100K B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 B.U.G. Rating for 700mA (TM15) in Lumens where B = Backlight, U = Uplight, G = Glare Temperature Type I Type II Type III Type III NFO Type IV Type IV NFO Type V Type L/R 3000K B3 U0 G3 B2 U0 G2 N/A N/A B0 U0 G2 B0 U0 G2 B3 U0 G3 B2 U0 G2 4200K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B3 U0 G3 B3 U0 G3 5100K B3 U0 G3 B3 U0 G3 B2 U0 G2 B2 U0 G2 B1 U0 G2 B0 U0 G2 B3 U0 G3 B3 U0 G3 Electrical Drive Current 350mA 700mA Volts - AC Amps - AC System Watts Volts - AC Amps - AC System Watts 120 0.38 46 120 0.78 93 208 0.22 46 208 0.45 93 240 0.19 46 240 0.39 93 277 0.17 46 277 0.34 93 347 0.13 46 347 0.27 93 480 0.10 46 480 0.19 93 LED performance and lumen output continues to improve at a rapid pace. Log onto www.kimlighting.com to download the most current photometric files from Kim Lighting’s IES File Library. For custom optics and color temperature configurations, contact factory. Spectroradiometric 3000K Average 4200K Average 5100K Average Correlated Color Temp. CCT (K)2800K - 3175K 3800K - 4600K 4600K - 5600K Color Rendering Index (CRI)≥75 ≥70 ≥65 Power Factor >.90 >.90 >.90 Projected Lumen Maintenance* mA 50,000 hrs 100,000 hrs 350 mA 96.67%94.48% 700 mA 92.51%87.87% *Still awaiting independent third party verification One Story 15,000 SF Two Story 33,600 SF FF = 379.6 82 SPACES DRSTSTUDUD STSTSTUDUDUDUDSTUDUDUDS STDAYLIGHT PERFORATED6" SDR 35 PVCINV. = 389.0±EX.SCREENEDSOLIDWASTESTORAGEDAYLIGHT PERFORATED6" SDR 35 PVCINV. = 393.0±EX. STEPSEX. CURBEX. BOLLARDLIGHTINGEX. SIDEWALKEX. HVAC &CONCRETEPADEX. SIDEWALKEX. YARD DRAIN #1RIM=394.5±INV.=392.2 EX. BIKE RACKEX. YARD DRAIN #2RIM=395.0±INV.=391.0±EX. YARD DRAIN #3RIM=390.0±INV.=386.8±RESERVED ACCESSIBLEPARKING SIGNS (2) SIGN"ONE WAY"PROPOSEDUTILITYCABINETS POLEMOUNTEDLIGHTING(TYP.)FLUSHCURBPROPOSEDCURBPROPOSEDSIDEWALKPROPOSED BOLLARDLIGHTING (TYP. FOR 6)EX. POLE MOUNTEDLIGHTING (TYP.)(4) PROPOSEDBIKE RACK ONCONC. PADSEE DETAILEX. FLUSHCURB EX. GRASS LINED SWALEEX. 12" HDPE W/ F.E.S.INV.=385.3 EX. 15" HDPE w/ FESINV.=378.8UDUDUDREPLACE EX.STOP SIGN 20'TO BERELOCATED SS ST STSTSTST STSTSNEW CB #1RIM=384.5INV.=381.0 NEW CB #3RIM=383.8INV.IN=380.4 (15"S)INV.OUT=380.3 (15"N)NEW CB #4RIM=384.2INV.IN=380.7 (15" S)INV.OUT=380.6 (15"N)12" HDPEF.E.S.INV.=382.3 NEW CB #5RIM=385.0INV.IN=381.3 (12" W)INV.OUT=381.2 (15"N)NOTE:SIGN SHALL BE RELOCATEDAS NECESSARY WHEN REC.PATH IS CONSTRUCTED.EXISTINGOFFICEBUILDINGA7,200 SFFFE 396.0 EAST MOUNTAIN VIEWMEDICAL OFFICE BUILDING EXISTING PAVEDPARKING AREAEXISTINGPAVED DRIVE EXISTINGPAVEDPARKING DR20' SANITARYSEWER & DRAINAGEEASEMENT IN FAVOROF LOT 1A20' EMERGENCYACCESS EASEMENTIN FAVOR OF LOT 1DREXISTINGPAVEDDRIVE**SNOW**STORAGEAREAEX. BLOCK WALLEX. BLOCK WALLEXISTINGSTORAGE BUILDINGA11,000 SFFFE 392.0EX. CEASIGN **SNOW STORAGE AREA**12" HDPE12" HDPE 15" HDPEFOX RUN LANE 710PROPOSEDOFFICEBUILDINGB(PHASE II)7,200 SFFFE 387.70 12" HDPE12" HDPE12" HDPE12" HDPE +391.5109 34VT ROUTE 116 - HINESBURG ROADMANSFIELD VIEW LANEEXISTINGPAVEDPARKING 385385386389390388387392393394395398397396393PS390ZONING DISTRICT -VILLAGE COMMERCIALZONING DISTRICT -NEIGHBORHOODRESIDENTIAL ZONING DISTRICT -INDUSTRIAL & OPENSPACESO. BURLINGTON REALTYCOMPANY, LLCRYEASSOCIATESCITY OF SO. BURLINGTONSO. BURLINGTON REALTY COMPANY, LLC HRG OFFICE BUILDING, LLCSBRC PROPERTIES, LLC."VIEW PROTECTION ZONE"EAST MOUNTAINVIEW, LLC PROPOSEDOFFICEBUILDING C4,346 SFFFE 386.10 36EXISTINGHOUSEEXISTINGGARAGE7 6 6PROPOSED SWALEPROPOSED SWALEPROPOSEDSWALEEX. SWALE + 387.6 + 386.0+ 389.2+ 388.9 + 385.2PROPOSEDSWALEEX. GRAVEL PATHNEW CB #2RIM= 383.6INV.IN=379.1 (15" S)INV.IN=379.1 (15"W)INV.OUT=379.0 (15"NE)EX. FENCEPROPOSEDSIDEWALKTTTTTT EX. GATE391384398397396395394394 392392381 381391390389389388388387 387387387386386 386386 385385385385385384384384384383384383383383383382 382380382379378384 S EX. GASMETER EX. CBRIM=381.9INV.=378.5SUMP=377.3380+ 386.2 + 385.4 + 384.1 + 383.5 382.7 ++ 386.5 + 383.52%2%+ 386.8+ TC 386.7BC 386.2 CURBOPENING+ 385.8+ TC 387.3BC 386.8+ TC 388.1BC 387.6+ 386.2+ 386.4 + TC 385.7BC 385.2+ TC 384.3BC 383.8+ TC 385.1BC 384.6+ 385.9+ 385.7+ 385.3+ 385.5+ 385.5+ 385.9+ 386.1+ 385.7+ TC 387.2BC 386.7+ TC 385.7BC 385.1 TC 385.1 +BC 384.6+ TC 386.3BC 385.8+ TC 387.5BC 387.0 END OF CURB+ 386.63.6%1.4%+ TC 388.1BC 387.6+ 387.2 + 385.5+ 385.7 15" HDPE+ 387.3(4) PROPOSEDBIKE RACK ONCONC. PADSEE DETAIL EX. GATEEX. SWALERE-ESTABLISHPRE-EXISTINGDRAINAGESWALE ACCIVIL ENGINEERING ASSOCIATES, INC.E10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.comDSMDSMMAB 1" = 30' 06248 C2.1 LOCATION MAP 1" = 2000'CEA PROPERTIES,LLC10 MANSFIELD VIEW LANESOUTH BURLINGTONVERMONT 05403CEA CAMPUSPLANNED UNITDEVELOPMENT SITE GRADING & DRAINAGE PLAN LOT 1AMEADOWLAND BUSINESS PARK SOUTH BURLINGTON, VTMEADOWLAND DR.KNOLLMILL POND LN.FOX RUN LANEOAK CREEK DR.BUTLER DRIVEDUBOIS DRIVE CIRCLEHINESBURG ROADCOMMUNITY DR.PROJECTLOCATION 8911610/16/19 DSM SKETCH PLAN SUBMITTALLEGENDFMUEGSTSTW100EXISTING CONTOUREXISTING CURBEXISTING PAVEMENTEXISTING SWALEWETLANDSWETLANDS BUFFEREXISTING UNDERGROUND ELECTRICEXISTING FORCEMAINEXISTING GASEXISTING STORMEXISTING GRAVITY SEWEREXISTING TELEPHONEEXISTING WATERSTREAMEXISTING SEWER MANHOLEEXISTING STORM MANHOLEEXISTING CATCH BASINEXISTING HYDRANTEXISTING SHUT OFFEXISTING UTILITY POLEEXISTING LIGHT POLEEXISTING GUY WIRE/POLEEXISTING SIGNEXISTING DECIDUOUS TREEEXISTING CONIFEROUS TREEEDGE OF BRUSH/WOODSAPPROXIMATE SETBACK LINEAPPROXIMATE PROPERTY LINEIRON ROD/PIPE FOUNDCONCRETE MONUMENT FOUNDSDEXISTING YARD DRAINOEEXISTING OVERHEAD ELECTRICFMGSTSTWUEPROPOSED CONTOUR100PROPOSED CURBPROPOSED PAVEMENTPROPOSED SWALEPROPOSED UNDERGROUND ELECTRICPROPOSED FORCEMAINPROPOSED GASPROPOSED STORMPROPOSED GRAVITY SEWERPROPOSED TELEPHONEPROPOSED WATERSPROPOSED SEWER MANHOLEPROPOSED CATCH BASINPROPOSED HYDRANTPROPOSED SHUT OFFPROPOSED LIGHT POLEPROPOSED SETBACK LINEPROPOSED SIGNNOTE:Contours shown are based upon a compilation of topographicsurvey information and existing LiDAR data. The contractor shallbe responsible for field verifying existing conditions and reportany discrepancies to the engineer prior to beginning work in thatarea.PROPOSED BOLLARD LIGHT 12/20/2019 P:\AutoCADD Projects\2006\06248-2019\1-CADD Files-\dwg\06248-Site.dwg, 12/19/2019 12:46:57 PM, DWG To PDF.pc3Avg. Existing Grade - 385.1 Avg. Existing Grade - 382.3 381.1382.1383.3382.6384.6385.2386.7 385.0383.8384.1