Loading...
HomeMy WebLinkAboutSP-23-013 - Plans - Record - 1233 Shelburne RoadTHE HOMESTEAD SCHOOL 1233F Shelburne Road (VT Route 7) South Burlington, Vermont ISSUED FOR PERMIT REVIEW NOT FOR CONSTRUCTION C-0.00 EXISTING OVERALL SITE PLAN APPROXIMATE PROPERTY LINES LEGEND IRON PIPE / CONCRETE MONUNMENT FOUND 164 Main Street, Suite 201 P: (802) 878-0375 Colchester, Vermont 05446 www.krebsandlansing.com EXISTING SEWER LINE/MANHOLE EXISTING STORM LINE/MANHOLE/BASIN EXISTING OVERHEAD ELECTRIC LINE/POWER POLE EXISTING UNDERGROUND POWER EXISTING WATER LINE/HYDRANT/VALVE/SHUTOFF STANDARD GRAPHIC SCALE (1" = 30') VALID WHEN PLOTTED ON 24" BY 36" MEDIA 0' 0"1"2"3" 15'30'60'90' STAMP: APPROXIMATE EASEMENTS EXISTING GAS LINE/VALVE 1.ASPECTS OF PLAN ARE APPROXIMATE AND DERIVED FROM VERMONT USGS, GIS FIGURES, AND AERIAL PHOTOGRAPHY. AERIAL PHOTOGRAPHY DATED MAY 2022. ASPECTS FROM 1233 SHELBURNE ROAD ARE DERIVED FROM OLD ACT 250 PERMIT PLANS, BUILDING BLUE PRINTS, AND HAVE NOT BEEN FIELD VERIFIED. 2.THE HORIZONTAL COORDINATE SYSTEM IS BASED ON NAD83 VERMONT STATE PLANE 4400 (US SURVEY FEET). ELEVATIONS ARE BASED ON THE NAVD88 (US SURVEY FEET). 3.THE UTILITIES ARE NOT WARRANTED TO BE COMPLETE. CONTRACTOR SHALL CONTACT DIG SAFE BEFORE BEGINNING ANY EXCAVATION. 4.THIS IS IN NO WAY A BOUNDARY SURVEY. PROPERTY LINES SHOWN ON THIS PLAN ARE FROM TAX MAP INFORMATION PROVIDED BY THE CITY. PROPERTY LINES HAVE BEEN ADJUSTED BASE ON MONUMENTATION FOUND IN THE FIELD AND EVIDENCE IN AERIAL PHOTOGRAPHY. PLAN NOTES: LOCATION MAP SCALE: 1" = 1 2 MILE SITE LAT: N44° 26' 08.5" LONG: W73° 12' 39.9" PROPERTY INFORMATION: ADDRESS: 1233F SHELBURNE ROAD PARCEL ID: 1540-1233F SPAN: 600-188-11945 GRANDLIST ACREAGE: 0.09 ACRES (CONDO) ZONING: COMMERCIAL 1 FRONT YARD BUILDING SETBACK: 30' BACK YARD BUILDING SETBACK: 30' SIDE YARD BUILDING SETBACK: 10' MAXIMUM BUILDING COVERAGE: 40% MAXIMUM TOTAL LOT COVERAGE: 70% PROPERTY OWNER/APPLICANT: REPERIO PROPERTIES, LLC C/O JEFF O'HARA P.O. BOX 1133 WILLISTON, VERMONT 05495 1 THE HOMESTEAD SCHOOL 1233F Shelburne Road (VT Route 7) South Burlington, Vermont ISSUED FOR PERMIT REVIEW NOT FOR CONSTRUCTION C-1.00 RETROFIT EXISTING COMMERCIAL BUILDING TO PROPOSED CHILDCARE FACILITY SITE PLAN APPROXIMATE PROPERTY LINES EXISTING GRADE CONTOUR LINES (5 FOOT INTERVALS) EXISTING TREELINE EXISTING GRADE CONTOUR LINES (1 FOOT INTERVALS) LEGEND IRON PIPE / CONCRETE MONUNMENT FOUND 164 Main Street, Suite 201 P: (802) 878-0375 Colchester, Vermont 05446 www.krebsandlansing.com EXISTING SEWER LINE/MANHOLE EXISTING STORM LINE/MANHOLE/BASIN EXISTING OVERHEAD ELECTRIC LINE/POWER POLE EXISTING UNDERGROUND POWER EXISTING WATER LINE/HYDRANT/VALVE/SHUTOFF SURVEY CONTROL POINT EXISTING SIGN STANDARD GRAPHIC SCALE (1" = 10') VALID WHEN PLOTTED ON 24" BY 36" MEDIA 0' 0"1"2"3" 5'10'20'30' STAMP: APPROXIMATE EASEMENTS EXISTING GAS LINE/VALVE 1.ASPECTS OF PLAN ARE APPROXIMATE AND DERIVED FROM VERMONT USGS, GIS FIGURES, AND AERIAL PHOTOGRAPHY. AERIAL PHOTOGRAPHY DATED MAY 2022. ASPECTS FROM 1233 SHELBURNE ROAD ARE DERIVED FROM OLD ACT 250 PERMIT PLANS, BUILDING BLUE PRINTS, AND HAVE NOT BEEN FIELD VERIFIED. 2.THE HORIZONTAL COORDINATE SYSTEM IS BASED ON NAD83 VERMONT STATE PLANE 4400 (US SURVEY FEET). ELEVATIONS ARE BASED ON THE NAVD88 (US SURVEY FEET). 3.THE UTILITIES ARE NOT WARRANTED TO BE COMPLETE. CONTRACTOR SHALL CONTACT DIG SAFE BEFORE BEGINNING ANY EXCAVATION. 4.THIS IS IN NO WAY A BOUNDARY SURVEY. PROPERTY LINES SHOWN ON THIS PLAN ARE FROM TAX MAP INFORMATION PROVIDED BY THE CITY. PROPERTY LINES HAVE BEEN ADJUSTED BASE ON MONUMENTATION FOUND IN THE FIELD AND EVIDENCE IN AERIAL PHOTOGRAPHY. PLAN NOTES: EXISTING WATER/WASTEWATER DESIGN FLOW: ·THERE IS NO EXISTING WW PERMIT FOR BUILDING "F" ON THIS PROPERTY. PROPERTY BEEN RUN AS A COMMERCIAL STORE. ·THERE ARE FLOW ALLOCATIONS OUTLINED IN THE VARIOUS ACT 250 PERMITS FOR THE PROPERTY FROM THE LATE 1980s. HOWEVER, IT IS DIFFICULT TO DETERMINE THE SPLIT OF FLOWS. THEREFORE, WE HAVE CALCULATED THE FLOWS BASED ON THE RULES OUTLINED IN THE WASTEWATER SYSTEM AND POTABLE WATER SUPPLY RULES EFFECTIVE DATE APRIL 12, 2019. ·±6,750 S.F. * 4 GPD PER 100 S.F. OF STORE = 270 GPD ·TOTAL = 270 GPD STATE OF VERMONT PROPOSED WASTEWATER/WATER DESIGN FLOWS: ·PROPOSED USE IS A CHILD CARE FACILITY WHICH DOES NOT SERVE MEALS ON SITE. TOTAL AMOUNT OF EMPLOYEES AND CHILDREN WHICH WILL USE THE PROPOSED FACILITY EQUALS 12 EMPLOYEES AND 65 CHILDREN ·77 EMPLOYEES & CHILDREN * 13 GPD PER PERSON WITHOUT MEALS = 1,001 GPD ·INCREASE OF 731 GPD BASIS OF DESIGN FOR POTABLE WATER AND WASTEWATER DESIGN FLOW 1233F PROPOSED USE PROPERTY INFORMATION: ADDRESS: 1233F SHELBURNE ROAD PARCEL ID: 1540-1233F SPAN: 600-188-11945 GRANDLIST ACREAGE: 0.09 ACRES (CONDO) ZONING: COMMERCIAL 1 FRONT YARD BUILDING SETBACK: 30' BACK YARD BUILDING SETBACK: 30' SIDE YARD BUILDING SETBACK: 10' MAXIMUM BUILDING COVERAGE: 40% MAXIMUM TOTAL LOT COVERAGE: 70% PROPERTY OWNER/APPLICANT: REPERIO PROPERTIES, LLC C/O JEFF O'HARA P.O. BOX 1133 WILLISTON, VERMONT 05495 1 ISSUED FOR PERMIT REVIEW NOT FOR CONSTRUCTION C-2.00 DETAILS 164 Main Street, Suite 201 P: (802) 878-0375 Colchester, Vermont 05446 www.krebsandlansing.com STAMP: THE HOMESTEAD SCHOOL 1233F Shelburne Road (VT Route 7) South Burlington, Vermont 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ALL DISTURBED AREAS BACK TO ORIGINAL CONDITION, INCLUDING BUT NOT LIMITED TO CURBING, SIDEWALKS, ROAD, PARKING AREAS, LANDSCAPING, SITE LIGHTING, ELECTRICAL, AND ETC. ALL ASPHALT SHALL BE SAW-CUT PRIOR TO PAVING. 2.THE METHODS AND MATERIALS OF CONSTRUCTION SHALL CONFORM TO THE LATEST STANDARDS OF THE STATE OF VERMONT AND CITY OF SOUTH BURLINGTON, ALL WORK SHALL BE IN CONFORMANCE WITH ALL PERMITS AND APPROVALS ISSUED FOR THE PROJECT. IN CASE OF CONFLICT, THE MORE STRINGENT SPECIFICATION SHALL APPLY AS DIRECTED BY ENGINEER. ALL WORK SHALL BE DONE IN A WORKMANLIKE MANNER AND COMPLETED IN THE TIME SPECIFIED BY OWNER. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS SHOWN AND REQUIRED TO MAKE THE JOB COMPLETE. THESE DRAWINGS DO NOT SHOW EVERY FITTING OR APPURTENANCE. MATERIALS SHALL BE AS SPECIFIED ON THE DRAWINGS. MANUFACTURER'S PRODUCT SPECIFICATIONS SHALL BE SUBMITTED FOR ALL MATERIALS TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. 4.THE LOCATION AND SIZE OF EXISTING UNDERGROUND UTILITIES IS NOT WARRANTED TO BE EXACT OR COMPLETE. THE CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES AND SHALL CONTACT THE AFFECTED UTILITY COMPANY, THE ENGINEER AND THE MUNICIPALITY PRIOR TO MAKING ANY HOOK UPS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXISTING UTILITIES AND THEIR UNINTERRUPTED SERVICES. ALL OFF-SITE BACKFILL, SHEETING, SHORING, DEWATERING, CLEARING AND GRUBBING, EROSION CONTROL, DUST CONTROL, TRAFFIC CONTROL, GRADING, AND ALL INCIDENTALS SHALL BE INCLUDED AS PART OF THE REQUIRED WORK. 5.THE CONTRACTOR SHALL VERIFY ALL TEMPORARY BENCH MARKS BEFORE USE. 6.THE WORKMEN AND PUBLIC SHALL BE PROTECTED BY THE CONTRACTOR FROM ANY AND ALL HAZARDS CONNECTED WITH THE CONSTRUCTION WORK. OPEN TRENCHES, MATERIALS, OR EQUIPMENT WITHIN THE WORKING LIMITS ARE TO BE GUARDED BY THE USE OF ADEQUATE BARRICADES OR FLAGMEN. ALL BARRICADES LEFT IN POSITION OVERNIGHT ARE TO BE PROPERLY LIGHTED. KEROSENE POTS ARE NOT ACCEPTABLE. WHEN WORK NARROWS THE USABLE PAVEMENT, FLAGMEN SHALL BE EMPLOYED TO AID THE FLOW OF TRAFFIC SO THAT THERE WILL BE NO UNDUE DELAYS. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE SAFETY OF ALL WORKMEN, THE GENERAL PUBLIC AND ALL DAMAGES TO PROPERTY OCCURRING FROM OR UPON THE WORK OCCASIONED BY NEGLIGENCE OR OTHERWISE GROWING OUT OF A FAILURE ON THE PART OF THE CONTRACTOR TO PROTECT PERSONS OR PROPERTY FROM HAZARDS OF OPEN TRENCHES, MATERIALS, OR EQUIPMENT AT ANY TIME OF THE DAY OR NIGHT WITHIN THE WORKING AREA. ALL WORK SHALL BE IN CONFORMANCE TO OSHA REGULATIONS, TITLE 19, PARTS 1926.651 AND 1926.652, AND APPLICABLE TO VOSHA REGULATIONS. 7.THE CONTRACTOR SHALL VERIFY ALL UTILITY INTERSECTIONS AND CONTACT ENGINEER AND OWNER WITH CONFLICTS. 8.THE CONTRACTOR SHALL CALL, DIG SAFE PRIOR TO ANY EXCAVATION. 9.THE CONTRACTOR SHALL COORDINATE FINAL LOCATION AND INVERTS FOR WATER, SEWER, AND STORM BUILDING CONNECTIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, AND MECHANICAL ENGINEER. 10.ALL STUMPS, ROCK, AND OTHER NON-APPROVED TRENCH BACKFILL MATERIAL DISCOVERED DURING CONSTRUCTION IS THE EXCLUSIVE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PROPERTY AND DISPOSED OF IN A STATE APPROVED DISPOSAL LOCATION. ALL EXISTING SOILS REUSED FOR FILL SHALL CONFORM TO ALL APPLICABLE SECTIONS OF VTRANS SPECIFICATIONS SECTION 203-EXCAVATION & EMBANKMENTS.CONTRACTOR SHALL REVIEW SOIL INVESTIGATION REPORT AND SOILS LOGS PRIOR TO BID. ANY SOIL REUSED AS FILL UNDER ROADS AND APPLICABLE CONCRETE SIDEWALKS SHALL PASS A SUBGRADE PROOF ROLL WITH A LOADED TANDEM. FILL SOILS THAT DO NOT PASS A SUBGRADE PROOF ROLL SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. 11.ALL PASSING SIEVE, PROCTOR, AND COMPACTION TESTING EXPENSES SHALL BE PAID BY OWNER. TESTING COORDINATION, ALL OTHER REQUIRED TESTING, AND EXPENSES FOR FAILED TESTS SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 12.THE CONTRACTOR SHALL CONTACT THE GREEN MOUNTAIN POWER (GMP) AND/OR BURLINGTON ELECTRIC PRIOR TO ANY WORK IN THE VICINITY OF THE EXISTING ELECTRIC CONDUITS. 13.THIS PROJECT WILL LIKELY NOT REQUIRE COVERAGE UNDER AN STATE OF VERMONT GENERAL CONSTRUCTION STORMWATER DISCHARGE PERMIT. THE CONTRACTOR WILL STILL FOLLOW RULES, REGULATIONS, AND DIRECTION OUTLINED IN THE STATE OF VERMONT "LOW RISK HANDBOOK FOR EROSION PREVENTION AND SEDIMENT CONTROL" FROM FEBRUARY 2020.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING, MAINTAINING AND REMOVING ALL EROSION AND SEDIMENT CONTROL DEVICES SHOWN ON THE PLANS OR DETAILS AND, TO THE MAXIMUM EXTENT PRACTICAL, TO MINIMIZE POTENTIAL CONTAMINATION OF STORMWATER RUNOFF FROM THE CONSTRUCTION ACTIVITIES. 14.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL "AS-BUILT" MEASUREMENT AND DRAFTING REQUIREMENTS AS OUTLINED ON THE DETAIL SHEETS. ALL TRENCH EXCAVATIONS SHALL REMAIN OPEN UNTIL ALL AS-BUILT SURVEY SHOTS HAVE BEEN TAKEN. PROGRESS RECORD DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER AS INDICATED IN THE RECORD DRAWING SPECIFICATIONS. 15.SEE EROSION CONTROL AND LOGISTICS PLANS FOR LOCATIONS OF STAGING / STORAGE AREAS. 16.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SIGNAGE AND CONSTRUCTION BARRIER/SAFETY FENCING NECESSARY FOR PROVIDING SAFE VEHICULAR AND PEDESTRIAN ACCESS THROUGH OR AROUND THE SITE DURING CONSTRUCTION. CONTRACTOR SHALL COORDINATE THIS WITH THE CITY OF SOUTH BURLINGTON AND THE CITY OF SOUTH BURLINGTON DEPARTMENT OF PUBLIC WORKS. 17.DEFINITION OF "PRECONSTRUCTION EXCAVATION" FOR THESE CONTRACT DOCUMENTS SHALL BE: THE SITE CONTRACTOR SHALL EXPOSE UTILITIES AND OBTAIN ALL NECESSARY INFORMATION, INCLUDING BUT NOT LIMITED TO, INVERT ELEVATION, SIZE, DEPTH, PIPE TYPE, JOINT LOCATION, ETC. CONTRACTOR SHALL TRANSIT SURVEY THE LOCATION AND ELEVATIONS OF THE UTILITY. CONTRACTOR SHALL PROVIDE THE ENGINEER WITH SKETCHES INDICATING HORIZONTAL AND VERTICAL INFORMATION OF PIPE OR CONDUIT TYPE AND SIZE, CROSS-SECTION INFORMATION, CONCRETE ENCASEMENT INFORMATION (TOP AND BOTTOM ELEVATIONS, WIDTH, ETC.), JOINT LOCATION, ETC. OF EACH REQUIRED EXISTING UNDERGROUND UTILITY. ACCURACY OF HORIZONTAL LOCATION IS WITHIN 1 FOOT, AND ACCURACY OF VERTICAL ELEVATION IS WITHIN 0.02 FT. (1/4"). COORDINATE ALL EXCAVATION WITH CITY, OWNER, AND ENGINEER. PRECONSTRUCTION EXCAVATIONS SHALL OCCUR PRIOR TO ORDERING STRUCTURES AND PRIOR TO UTILITY CONSTRUCTION TO FACILITATE REDESIGN AND/OR DESIGN CONFIRMATION. 18.THE LOCATION OF THE PRECONSTRUCTION EXCAVATION SYMBOLS DOES NOT NECESSARILY INDICATE THE LOCATION OF THE BURIED UTILITY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIND AND EXPOSE THE UTILITY. 19.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS OF IMPORTING AND PLACING TOPSOIL AND/OR COMPOST NECESSARY TO COMPLETE THE PROJECT. CONTRACTOR SHALL TEST TOPSOIL FOR APPROVAL BY THE OWNER AND ENGINEER. 10.ALL SEWER AND STORM PIPES SHALL BE PVC SDR 35 UNLESS OTHERWISE NOTED. ALL NEW SANITARY AND STORM PIPES SHALL BE LAID WITH A LASER TO ELEVATION AND SLOPE AS SHOWN ON THE PLANS. 11.CORE AND BOOT ALL EXISTING STRUCTURES UNLESS OTHERWISE NOTED. 12.ALL NEW CATCH BASINS AND SANITARY SEWER MANHOLE MUST HAVE ONE 6" PRECAST CONCRETE GRADE RING. 13.ALL WATERLINE PIPE SHALL BE DUCTILE IRON CLASS 52. ALL BENDS AND FITTINGS SHALL HAVE REDI-MIX CAST IN PLACE THRUST BLOCKS 14.TEMPORARY GROUNDWATER, STORMWATER, AND SEWER BY-PASS PUMPING AND/OR DIVERSION IS THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY PUMPS AND EQUIPMENT TO PERFORM THE WORK. OVERNIGHT PUMPING IS NOT ALLOWED. 15.ALL SIDEWALKS SHALL HAVE 2% MAXIMUM CROSS SLOPE. ALL RAMPS AND STAIRS SHALL HAVE A LANDING AT THE BOTTOM WITH A MAXIMUM SLOPE OF 2% FOR 5 FEET. 16.CONTRACTOR TO PIN CONCRETE SIDEWALK/SLABS TO ALL CONTACT POINTS WITH STAIRS, BUILDING, BIKE SLAB, RETAINING WALLS, ETC. 17.CONTRACTOR SHALL MAINTAIN FULL OCCUPANCY AND FIRE DEPARTMENT ACCESS TO ALL SURROUNDING BUILDINGS. COORDINATE ALL TEMPORARY ACCESS WITH THE MUNICIPALITY. 18.BURIED NATURAL GAS IS SHOWN FOR ALIGNMENT PURPOSES ONLY. CONTACT VERMONT GAS SYSTEMS FOR DESIGN AND DETAILS OF NEW GAS LINE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE EXCAVATION, BACKFILL, AND RESTORATION FOR THE CONSTRUCTION OF THE NATURAL GAS LINES. VERMONT GAS SYSTEMS WILL PROVIDE THE PIPING, LABOR TO INSTALL, AND TESTING FOR THE NEW GAS MAIN. COORDINATE WORK AND ALL GAS SHUT DOWN PROCEDURES WITH THE OWNER. 19.REMOVAL OF ALL EROSION CONTROL IS THE RESPONSIBILITY OF THE CONTRACTOR. 20.AT THE END OF THE PROJECT, CLEAN THE SUMPS OF ALL NEW AND EXISTING CATCH BASINS AND STORM MANHOLES WITHIN THE PROJECT LIMITS. 21.ELECTRICAL AND LIGHTING ARE SHOWN FOR ILLUSTRATIVE/COORDINATION PURPOSES ONLY. REFER TO ELECTRICAL PLANS AND SPECIFICATIONS FOR DESIGN. 22.SEE LANDSCAPE AND/OR STRUCTURAL PLANS FOR ALL RETAINING WALLS, UTILITY PADS, STAIRS, AND EXTERIOR CONCRETE AT DOORS. 23.REFER TO PLUMBING, MECHANICAL AND/OR FIRE PROTECTION PLANS FOR WATER, SEWER AND STORM DESIGN WITHIN FIVE FEET OF THE BUILDING. GENERAL CONSTRUCTION NOTES: 1.EROSION PREVENTION AND SEDIMENT CONTROL (EPSC) PRACTICES SHALL BE IMPLEMENTED IN ALL AREAS WHERE THERE IS AN INCREASED RISK OF EROSION, AND WHERE THERE IS POTENTIAL FOR DISCHARGE OF STORMWATER RUNOFF (EITHER DIRECT OR INDIRECT) TO A WATER BODY. 2.EPSC MEASURES SHALL BE INSTALLED PRIOR TO ANY EARTH DISTURBING ACTIVITIES WITHIN A GIVEN DRAINAGE AREA WITH THE EXCEPTION OF LAND DISTURBANCE THAT MAY RESULT FROM ACCESSING THE AREA(S) WITH EQUIPMENT IN WHICH EPSC MEASURES ARE TO BE INSTALLED. THIS EXCEPTION INCLUDES LAND DISTURBANCE THAT MAY RESULT FROM ACCESS OF EQUIPMENT THAT IS NEEDED FOR:EXPLORATION AND/OR EPSC MEASURE INSTALLATION PHASES OF THE PROJECT. TEMPORARY SEDIMENT BASINS, TEMPORARY SEDIMENT TRAPS, PERIMETER DIKES, TEMPORARY SEDIMENT BARRIERS, AND OTHER TEMPORARY MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE WITH THE EXCEPTION OF THOSE ACTIVITES STATED ABOVE. EARTH DISTURBANCE INCLUDES STUMPING AND GRUBBING OF CLEARED AREAS. 3.EPSC MEASURES SHALL BE INSTALLED PURSUANT TO THE EPSC PLAN, THE 2020 STATE OF VERMONT LOW RISK SITE HANDBOOK FOR EROSION PREVENTION AND SEDIMENT CONTROL, THE 2020 VERMONT EROSION PREVENTION AND SEDIMENT CONTROL STANDARDS AND SPECIFICATIONS, AND/OR ANY OTHER RELEVANT PROJECT PERMITS. 4.ALL PROPOSED CHANGES SHALL BE APPROVED BY THE ON-SITE PLAN COORDINATOR (OSPC) OR HIS/HER DESIGNEE PRIOR TO IMPLEMENTATION. 5.NO MAJOR CLEARING/LOGGING ACTIVITIES ARE PROPOSED FOR THE PROJECT. 6.PERMISSION MUST BE GRANTED BY VT DEC PRIOR TO USE OF ANY SUPPORT ACTIVITIES OCCURRING OUTSIDE OF THE APPROVED PROJECT BOUNDARIES. 7.ALL PARTIES ASSOCIATED WITH CONSTRUCTION ACTIVITIES WHO MEET EITHER OF THE FOLLOWING TWO CRITERIA OF “PRINCIPAL OPERATOR” MUST OBTAIN COVERAGE UNDER THE CONSTRUCTION STORMWATER DISCHARGE PERMIT FOR THE PROJECT PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITIES BY THAT OPERATOR: A.THE PARTY HAS OPERATIONAL CONTROL OVER CONSTRUCTION PLANS AND SPECIFICATION, INCLUDING BUT NOT LIMITED TO THE ABILITY TO MAKE MODIFICATIONS TO THOSE PLANS AND SPECIFICATIONS; OR B.THE PARTY HAS CONTINUOUS DAY-TO-DAY OPERATIONAL CONTROL OF THOSE ACTIVITIES AT THE PROJECT THAT ARE NECESSARY TO ENSURE COMPLIANCE WITH AN EPSC PLAN FOR THE SITE OR OTHER PERMIT CONDITIONS (E.G., THEY ARE AUTHORIZED TO DIRECT WORKERS AT A SITE TO CARRY OUT ACTIVITIES REQUIRED BY THE EPSC PLAN OR COMPLY WITH OTHER PERMIT CONDITIONS). 1.EXISTING VEGETATION SHALL BE PROTECTED AND MAINTAINED TO THE EXTENT PRACTICABLE. 2.A VEGETATED BUFFER SHALL BE MAINTAINED FOR WATER BODIES WHERE FEASIBLE (E.G., WETLANDS AND STREAMS). 3.TO THE EXTENT PRACTICABLE, SURFACE FLOW SHALL BE DIVERTED AWAY FROM EXPOSED SOILS VIA DIVERSION BERMS, EARTH DIKES, PERIMETER DIKES/SWALES, TEMPORARY SWALES, WATER BARS, AND/OR CHECK DAMS. 4.RESOURCE AREAS (E.G., WETLANDS, STREAMS, RTE PLANT SPECIES) SHALL BE FLAGGED PRIOR TO ANY CONSTRUCTION RELATED ACTIVITIES OCCURRING WITHIN CLOSE PROXIMITY TO THOSE AREAS. 5.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT VIOLATE WATER QUALITY STANDARDS OR CONTRIBUTE TO EROSION. DEWATERING DETAILS SHALL BE REVIEWED AND APPROVED BY OSPC PRIOR TO USE. 6.CONCENTRATED RUNOFF SHALL NOT FLOW DOWN STEEP SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL (SEE DETAILS), FLUME, OR SLOPE DRAIN STRUCTURE. 7.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES, WHERE FEASIBLE, BUT NOT IN RESOURCE AREAS. 8.WHERE FEASIBLE, ALL SEDIMENT REMOVED FROM SEDIMENT CONTROL PRACTICES AS PART OF MAINTENANCE SHALL BE DISPOSED OF IN AN AREA THAT IS AT LEAST ONE OF THE FOLLOWING, WITH IMMEDIATE STABILIZATION FOLLOWING DISPOSAL OF MATERIAL: A. LESS THAN 5±% SLOPE B. AT LEAST 100 FEET FROM ANY DOWNSLOPE WATER BODY OR CONVEYANCE TO A WATER BODY, INCLUDING A DITCH C. VEGETATED 9.DISTURBED AREAS BORDERING OR DRAINING TO EXISTING ROADS SHALL HAVE AN APPROPRIATE SEDIMENT BARRIER (E.G., SILT FENCE) SPANNING THE EDGE OF THE DISTURBANCE TO PREVENT WASHING OF SEDIMENT ONTO ROADWAYS OR INTO ROAD DITCHES. 10.IN ADVANCE OF PREDICTED RAINFALL OR SNOWMELT, ALL EPSC MEASURES THAT ARE LOCATED IN ACTIVE AREAS OF EARTH DISTURBANCE SHALL BE INSPECTED AND REPAIRED, AS NEEDED. IF NECESSARY, THIS SHALL INCLUDE TEMPORARY STABILIZATION OF ALL DISTURBED SOILS ON THE SITE IN ADVANCE OF THE ANTICIPATED RUNOFF PERIOD. 11.DUST CONTROL SHALL BE HANDLED VIA WATER APPLICATION TO ROADWAYS AND OTHER AREAS WHERE DUST MAY BE GENERATED. EPSC GENERAL NOTES: EPSC CONSTRUCTION NOTES: 1.ALL AREA DISTURBED AND ALL AREAS WITHIN THE CLEARING LIMITS SHALL BE GRADED AND COVERED WITH A MINIMUM OF 6" OF LOAM TOPSOIL. ADDITIONAL TOPSOIL DEPTHS AND SPECIFICATIONS MAY BE OUTLINED BY THE LANDSCAPE ARCHITECT FOR SPECIFIC AREAS. THE AREAS TO BE LOAMED SHALL BE FREE AND CLEAR OF ROOTS, WASTE MATERIAL AND OTHER DELETERIOUS MATERIAL. TOPSOIL SHALL BE SPREAD AND LIGHTLY COMPACTED TO A DEPTH OF 6". TOPSOIL SHALL BE APPROVED BY THE ENGINEER AND/OR LANDSCAPE ARCHITECT. ALL SIDE SLOPES ARE TO BE LOAMED. 2.ALL TURF ESTABLISHMENT SHALL BE IN ACCORDANCE WITH SECTION 651 OF THE VT STANDARD SPECIFICATIONS 2018 AND THE MUNICIPALITY SPECIFICATIONS. MULCHING SHALL FOLLOW SEEDING BY NO MORE THAN 24 HOURS. 3.ALL CUT SLOPES SHALL BE NO STEEPER THAN 2.0H ON 1.0V. ALL FILL SLOPES SHALL BE NO STEEPER THAN 2.0H ON 1.0V. 4.THE CONTRACTOR SHALL NOT DISTURB ANY GROUND BETWEEN OCTOBER 15TH BETWEEN APRIL 15TH WINTER MONTHS, UNLESS APPROVED BY THE ENGINEER. 5.TEMPORARY SILT FENCE SHALL BE ERECTED PRIOR TO ANY CLEARING OR CONSTRUCTION. FENCING MAY BE ERECTED IN PHASES, BUT IN NO CASE SHALL GROUND DISTURBANCE PROCEED FENCING. SPECIAL AREAS MAY BE DESIGNATED BY THE OWNER FOR PRESERVATION OF EXISTING TREES. THESE AREAS SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INSURE NO DAMAGE IS DONE TO DESIGNATED TREES. 6.EXISTING PLANTINGS ARE LOCATED IN GENERAL AREAS AS SHOWN ON THIS PLAN. CONTRACTOR SHALL PROTECT PLANTINGS SO AS NOT TO DAMAGE THESE OR THEIR ROOT SYSTEMS. 7.SLOPE STABILITY BASED UPON UNSATURATED SOIL CONDITIONS. IF DURING CONSTRUCTION SATURATED SOILS ARE ENCOUNTERED, CONTACT THE ENGINEER IMMEDIATELY. GENERAL GRADING AND SITE WORK NOTES 3'-0"BIKE RACK DETAIL 24" NEW CLASSIC U/2 BIKE RACK BY CYCLESAFE OR APPROVED EQUAL WITH CYCLESAFE BLACK PLASTISOL RUBBERIZED COATING 4'-0"7'-0" 4" MIN. 12" THICK GRAVEL SUBBASE (VAOT 704.05, FINE)MIN. FROMEDGE OFPAVEMENTMIN. BETWEENRACKS2'-6"2'JACKET COATING TO EXTEND 1" MIN. BELOW GRADE 9" THICK CONCRETE PAD TO BE POURED FOR SETTING AND ALIGNING BIKE RACK POSTS. SEE NEW CONCRETE SIDEWALK DETAIL FOR CONCRETE DESIGN. 26"26"9" MIRAFI 500X EXISTING OR NEW CONCRETE SIDEWALK. IF BIKE RACKS ARE RETROFITTED TO INSTALL ON EXISTING CONCRETE SIDEWALK, LIKE THIS PROJECT, THEY CAN BE MECHANICALLY FASTENED TO THE CONCRETE SLAB PER MANUFACTURES SPECIFICATIONS. 6" N.T.S. PROPERTY INFORMATION: ADDRESS: 1233F SHELBURNE ROAD PARCEL ID: 1540-1233F SPAN: 600-188-11945 GRANDLIST ACREAGE: 0.09 ACRES (CONDO) ZONING: COMMERCIAL 1 FRONT YARD BUILDING SETBACK: 30' BACK YARD BUILDING SETBACK: 30' SIDE YARD BUILDING SETBACK: 10' MAXIMUM BUILDING COVERAGE: 40% MAXIMUM TOTAL LOT COVERAGE: 70% PROPERTY OWNER/APPLICANT: REPERIO PROPERTIES, LLC C/O JEFF O'HARA P.O. BOX 1133 WILLISTON, VERMONT 05495 MIN. BETWEEN RACKS 6'-0" WHEN RACKS ARE INSTALLED IN SERIES ALONG A LONG CONCRETE SLAB/SIDEWALK. THE RACKS WILL BE SPACED WITH 6' (72") BETWEEN RACKS 1 ISSUED FOR PERMIT REVIEW NOT FOR CONSTRUCTION C-2.01 DETAILS 164 Main Street, Suite 201 P: (802) 878-0375 Colchester, Vermont 05446 www.krebsandlansing.com STAMP: TEMPORARY SEED MIX SHALL BE USED BETWEEN 9/16 AND 5/14 AND SHALL MEET THE FOLLOWING CRITERIA: PERMANENT SEED MIX SHALL BE USED AS EARLY AS PRACTICABLE BETWEEN 5/15 AND 9/15 AND SHALL MEET THE FOLLOWING CRITERIA: SEED % WEIGHT RED FESCUE 50% SHEEP FESCUE 25% RED TOP 5% WHITE CLOVER 10% ANNUAL RYE 10% FLOW SLOPE A A TO BE INSTALLED AT THE LIMITS OF THE CONSTRUCTION AREA. SEE PLANS.4' MIN.1.ACCEPTABLE EPSC MEASURE DETAILS ARE PROVIDED BELOW. 2.AT A MINIMUM, EPSC MEASURES MEET VT DEC STANDARDS AND SPECIFICATIONS FOR EROSION PREVENTION AND SEDIMENT CONTROL OR PREVIOUSLY APPROVED INTERCHANGEABLE PRACTICES. 3.LIMITS OF DISTURBANCE (OR "CONSTRUCTION DEMARCATION") SHALL BE INSTALLED PRIOR TO ANY EARTH DISTURBING ACTIVITIES. 4.BARRIER TAPE/ROPE: FOR USE WHERE PROPOSED DISTURBANCE BORDERS NON-WOODED, VEGETATED AREAS MORE THAN 100 FT FROM THE NEAREST WATER RESOURCE (STREAM, BROOK, LAKE, POND, WETLAND, ETC.). BARRIER TAPE IS HIGH VISIBILITY FIBERGLASS TAPE, MINIMUM 3" IN WIDTH COMMONLY USED IN SKI AREAS FOR DEMARCATING CLOSED AREAS. BARRIER TAPE AND ROPE SHOULD BE ATTACHED TO STAKES, AT A MINIMUM HEIGHT OF 4 FT FROM THE GROUND. 5.MINIMUM 1 TO 2 ROWS OF MESH BARRIER TAPE TO BE INSTALLED ALONG CONSTRUCTION PERIMETER. 6.EACH ROW OF BARRIER TAPE TO BE 3" WIDE MINIMUM. 7.BARRIER TAPE TO BE ORANGE. 8.SECURE BARRIER TAPE TO STAKES OR EXISTING TREE TRUNKS WITH BOTTOM ROW AT 4' DISTANCE FROM GROUND SURFACE (MINIMUM). 9.MAINTAIN AND REPLACE AS NEEDED. REMOVE AT COMPLETION OF PROJECT PER OSPC. 10.IN EVENT THE OSPC DETERMINES BARRIER TAPE IS NOT SUFFICIENT, REPLACE WITH ORANGE CONSTRUCTION FENCE OR SNOW FENCE. 20" MIN. 16" MIN. 10' MAX. 1.AT A MINIMUM, EPSC MEASURES MEET VT DEC STANDARDS AND SPECIFICATIONS FOR EROSION PREVENTION AND SEDIMENT CONTROL OR PREVIOUSLY APPROVED INTERCHANGEABLE PRACTICES. 2.PERIMETER CONTROLS SHALL BE UTILIZED IN SMALL AREAS < 1 ACRE. IN AREAS > 1 ACRE, TEMPORARY SEDIMENT TRAPS OR TEMPORARY SEDIMENT BASINS ARE TO BE UTILIZED. 3.PERIMETER CONTROLS SHALL BE INSTALLED ON DOWNSLOPE SIDE OF PLANNED EARTH DISTURBANCE. 4.PERIMETER CONTROLS SHALL BE INSTALLED PRIOR TO ANY EARTH DISTURBING ACTIVITIES WITHIN UPSLOPE CONTRIBUTING AREA. 5.SILT FENCE SHALL NOT BE USED AS CONSTRUCTION DEMARCATION. 6.SILTSOXX CAN BE USED AS A SILT FENCE ALTERNATIVE, WITH PRIOR APPROVAL OF THE ENGINEER. SEE DETAIL. 7.IF SILT FENCE IS INSTALLED WHEN GROUND IS FROZEN, A GRAVEL, SHOT ROCK, OR SAND BALLAST MUST BE USED. GUIDE TO MULCH MATERIALS, RATES, AND USES QUALITY STANDARDS PER 1000 SQ. FT.PER ACRE DEPTH OF APPLICATION REMARKS WOOD CHIPS OR SHAVINGS AIR-DRIED. FREE OF OBJECTIONABLE COARSE MATERIAL 500-900 LBS 10-20 TONS 2 - 7"USED PRIMARILY AROUND SHRUB AND TREE PLANTINGS AND RECREATION TRAILS TO INHIBIT WEED COMPETITION. RESISTANT TO WIND BLOWING. DECOMPOSES SLOWLY. WOOD FIBER CELLULOSE (PARTLY DIGESTED WOOD FIBERS) MADE FROM NATURAL WOOD USUALLY WITH GREEN DYE AND DISPERSING AGENT 50 LBS 2,000 LBS.-APPLY WITH HYDROMULCHER. NO TIE DOWN REQUIRED. LESS EROSION CONTROL PROVIDED THAN 2 TONS OF HAY OR STRAW. GRAVEL, CRUSHED STONE OR SLAG WASHED; SIZE 2B OR 3A - 112"9 CU. YDS.405 CU. YDS.3"EXCELLENT MULCH FOR SHORT SLOPES AND AROUND PLANTS AND ORNAMENTALS. USE 2B WHERE SUBJECT TO TRAFFIC. (APPROXIMATELY 2,000 LBS./CU. YD.). FREQUENTLY USED OVER FILTER FABRIC FOR BETTER WEED CONTROL. HAY OR STRAW AIR-DRIED; FREE OF UNDESIRABLE SEEDS & COARSE MATERIALS 90-100 LBS 2-3 BALES 2 TONS (100-120 BALES) COVER ABOUT 90% SURFACE USE SMALL GRAIN STRAW WHERE MULCH IS MAINTAINED FOR MORE THAN THREE MONTHS. SUBJECT TO WIND BLOWING UNLESS ANCHORED. MOST COMMONLY USED MULCHING MATERIAL. PROVIDES THE BEST MICRO-ENVIRONMENTAL FOR GERMINATING SEEDS. COMPOST UP TO 3" PIECES, MODERATELY TO HIGHLY STABLE 3-9 CU. YDS.134-402 CU. YDS.1 - 3"COARSER TEXTURED MULCHES MAY BE MORE EFFECTIVE IN REDUCING WEED GROWTH AND WIND EROSION. EROSION CONTROL MIX WELL-GRADED MIXTURE OF PARTICLE SIZES. ORGANIC CONTENT BETWEEN 80-100%, DRY WEIGHT. PARTICLE SIZE SHALL PASS 6" SCREEN (100%) * SLOPES 3(HZ.):1(VERT.) OR FLATTER = 2 INCH DEPTH PLUS ADDITIONAL 1/2 INCH DEPTH PER 20 FT. OF SLOPE UP TO 100 FT. ** SLOPES BETWEEN 3(HZ.):1(VERT.) AND 2(HZ.):1(VERT.) = 4 INCH DEPTH PLUS ADDITIONAL 1/2 INCH PER 20 FT. OF SLOPE UP TO 100 FT. *** SLOPES STEEPER THAN 2(HZ.):1(VERT.) USE OF EROSION CONTROL MIX AND MULCH DEPTH TO BE REVIEWED AND APPROVED PRIOR TO USE BY OSPC OR EPSC SPECIALIST COMPRISED OF SHREDDED BARK, STUMP GRINDINGS, COMPOSTED BARK, OR ACCEPTABLE MANUFACTURED PRODUCTS. MAY CONTAIN ROCK < 4" IN DIAMETER. ORGANICS SHALL BE FIBROUS AND ELONGATED. NO LARGE PORTIONS OF SILTS, CLAYS OR FINE SANDS. 5"-12" 1.CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION, MAINTENANCE, AND REMOVAL OF SILTSOXX IN ALL LOCATIONS SHOWN ON THE PLANS. SILTSOXX MAY BE LEFT IN PLACE IF THE CONTRACTOR SEEDS AND MULCHES OVER SILTSOXX FOR GROWTH POST CONSTRUCTION. 2.MAINTENANCE SHALL BE PERFORMED AS NEEDED AND ADDITIONAL WATTLES WILL BE ADDED WHEN SEDIMENT REACHES HALF OF PRODUCT HEIGHT. 3.WHEN INSTALLING LENGTHS OF SILTSOXX, LENGTHS WILL OVERLAP BY MINIMUM 18" WHEN TRANSITIONING TO A NEW LENGTH OF SILTSOXX. 4.CONTRACTOR SHALL REFER TO ALL MANUFACTURES SPECIFICATIONS AND DETAILS. 5.SILTSOXX IS A SPECIFIC MANUFACTURER, OTHER MANUFACTURERS WITH EQUAL PRODUCTS MAY BE USED IF APPROVED BY ENGINEER. 6.SILTSOXX CAN BE USED AS A SILT FENCE ALTERNATIVE, WITH PRIOR APPROVAL OF THE ENGINEER. NOTES SEED % WEIGHT %GERMINATION WINTER RYE 80% MIN.85% MIN. RED FESCUE (CREEPING)4% MIN.80% MIN. PERENNIAL RYE GRASS 3% MIN.90% MIN. RED CLOVER 3% MIN.90% MIN. OTHER CROP GRASS 0.5% MAX. NOXIOUS WEED SEED 0.5% MAX. INERT MATTER 1% MAX. SEEDING SPECIFICATIONS NOTES 5" TO 12" DIAMETER SILTSOXX, OR APPROVED EQUAL, MAY BE USED IN LOCATIONS SHOWN ON PLANS OR AS AN ALTERNATE TO SILT FENCE ONLY WITH PRIOR APPROVAL FROM ENGINEER. SIZE OF SILTSOXX WILL BE BASED ON APPLICATION, CHECK WITH ENGINEER FOR SIZE.OVERLAP BETWEEN WATTLE LENGTHS, 18" MIN. WATTLES SHALL BE STAKED WITH TYPICAL WOOD STAKES AT 10 FT. ON CENTER. N.T.S. TYPICAL SILTSOXX SEDIMENT CONTROL 36" STAKES DRIVEN ON DOWNSLOPE SIDE OF FENCE SLOPE FILTER FABRIC ATTACHED TO STAKES ON UPSLOPE SIDE. 36" MIN. STAKE FILTER FABRIC FORM 6" MIN. DEEP TRENCH. LAY FABRIC IN BOTTOM COVER WITH COMPACTED SOIL OR STONE BALLAST SECTION A-A SILT FENCE SPACING CHART SPACINGSLOPE 5% TO 10% 10% TO 20% > 20%15 FT. OR LESS 25 FT. OR LESS 50 FT. OR LESS NOTES N.T.S. TYPICALTEMPORARY SILT FENCE FASTEN FENCE TO STAKE WOODEN STAKE ORANGE POLYESTER MESH WEBBING BY WORLD CUP SUPPLY OR APPROVED EQUAL. (3" WIDE MIN.) A A N.T.S. TYPICAL CONSTRUCTION LIMIT BARRIER SECTION A-A INCORRECT SILT FENCE INSTALLED PARALLEL TO SLOPE (PERPENDICULAR TO CONTOUR) IN ONE, LONG RUN 30° NOTE: J-HOOKS SHALL BE USED WHENEVER THE SILT FENCE LINE IS INSTALLED AT AN ANGLE OF 30 DEGREES OR GREATER FROM PARALLEL TO THE CONTOURS CORRECT SILT FENCE INSTALLED IN SHORTER RUNS WITH J-HOOKS TO AVOID CONCENTRATION OF FLOWS AT ONE LOCATION BY TRAPPING RUNOFF AT MULTIPLE POINTS ALONG A SLOPE. 1. PROPER INSTALLATION OF J-HOOKS PROVIDES SILT FENCE THE ABILITY TO TEMPORARILY POND RUNOFF, ALLOWING TIME FOR SEDIMENTS TO SETTLE. 2. LONG RUNS OF SILT FENCE BETWEEN J-HOOKS SHOULD BE AVOIDED REFER TO ADJACENT TABLE FOR PROPER SPACING OF J-HOOKS. 3. J-HOOKS SHOULD BE BUILT ALONG CONTOUR IN A "SMILE" SHAPE WITH A MINIMUM WIDTH OF 20 FEET AND MINIMUM DEPTH OF 10 FEET. 4. ALONG A NARROW RIGHT OF WAY, NARROWER J-HOOKS CAN BE USED WITH A HIGHER SPACING FREQUENCY. 20' 10' SLOPE STEEPNESS MAXIMUM SPACING BETWEEN SILT FENCE J-HOOKS (FT.) 2:1 SLOPE (50%) 3:1 SLOPE (33%) 4:1 SLOPE (25%) 5:1 SLOPE OR FLATTER (50%) 25 50 75 100 NOTES SLOPE SLOPE SILT FENCE SILT FENCELIMITS OF CLEARING LIMITS OF CLEARING AVOID LARGE GAPS BETWEEN BOTTOM OF ABOVE GRADIENT J-HOOK AND THE NEXT SILT FENCE LINE. (6" MAXIMUM) N.T.S. TYPICAL SILT FENCE "J-HOOK" CONSTRUCTION ORANGE POLYESTER MESH WEBBING BY WORLD CUP SUPPLY OR APPROVED EQUAL. (3" WIDE MIN.) WOODEN STAKE AREA TO BE PROTECTED WORK AREA FLOW 5" TO 12" DIAMETER SILTSOXX, OR APPROVED EQUAL. SIZE OF SILTSOXX WILL BE BASED ON APPLICATION, CHECK WITH ENGINEER FOR SIZE. CONCRETE BLOCKS OR SAND BAGS FOR SUPPORT FOR SILTSOXX, 10' ON CENTER. IF SLOPES PERMIT SILTSOXX MAY NOT NEED SUPPORT. AREA TO BE PROTECTED PLAN SECTION N.T.S. TYPICAL SILTSOXX INSTALLATION ON PAVEMENT 1.CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION, MAINTENANCE, AND REMOVAL OF SILTSOXX IN ALL LOCATIONS SHOWN ON THE PLANS. 2.MAINTENANCE SHALL BE PERFORMED AS NEEDED AND ADDITIONAL SILTSOXX WILL BE ADDED WHEN SEDIMENT REACHES HALF OF PRODUCT HEIGHT. 3.WHEN INSTALLING LENGTHS OF SILTSOXX, LENGTHS WILL OVERLAP BY MINIMUM 2' WHEN TRANSITIONING TO A NEW LENGTH OF WATTLE. 4.CONTRACTOR SHALL REFER TO ALL MANUFACTURES SPECIFICATIONS AND DETAILS. 5.SILTSOXX IS A SPECIFIC MANUFACTURER, OTHER MANUFACTURERS WITH EQUAL PRODUCTS MAY BE USED IF APPROVED BY ENGINEER. NOTES CATCH BASIN N.T.S. SILTSOXX INLET PROTECTION WIRE TIES STORM GRATE 5" TO 12" DIAMETER SILTSOXX, OR APPROVED EQUAL. SIZE OF SILTSOXX WILL BE BASED ON APPLICATION, CHECK WITH ENGINEER FOR SIZE. DRAIN INLET PLAN CURBSIDE OPTION A CURBSIDE OPTION B 5" TO 12" DIAMETER SILTSOXX, OR APPROVED EQUAL. SIZE OF SILTSOXX WILL BE BASED ON APPLICATION, CHECK WITH ENGINEER FOR SIZE. STORM GRATE MATERIAL TO BE DRAWN IN AND TIED OFF TO WOODEN STAKECURB CURB CATCH BASIN 5" TO 12" DIAMETER SILTSOXX, OR APPROVED EQUAL. SIZE OF SILTSOXX WILL BE BASED ON APPLICATION, CHECK WITH ENGINEER FOR SIZE. CURB MATERIAL TO BE DRAWN IN AND TIED OFF TO WOODEN STAKE SECURE TO GRATE WITH TIE DOWNS DRAIN INLET SECTION CURBSIDE SECTION 1.CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION, MAINTENANCE, AND REMOVAL OF SILTSOXX IN ALL LOCATIONS SHOWN ON THE PLANS. 2.MAINTENANCE SHALL BE PERFORMED AS NEEDED AND ADDITIONAL SILTSOXX WILL BE ADDED WHEN SEDIMENT REACHES HALF OF PRODUCT HEIGHT. 3.WHEN INSTALLING LENGTHS OF SILTSOXX, LENGTHS WILL OVERLAP BY MINIMUM 2' WHEN TRANSITIONING TO A NEW LENGTH OF WATTLE. 4.CONTRACTOR SHALL REFER TO ALL MANUFACTURES SPECIFICATIONS AND DETAILS. 5.SILTSOXX IS A SPECIFIC MANUFACTURER, OTHER MANUFACTURERS WITH EQUAL PRODUCTS MAY BE USED IF APPROVED BY ENGINEER. NOTES 3B. 1. 6. 7. 2. 5. 4.8. 3. 1. 3A. NOTE: BLANKET SHALL BE USED ON SLOPES 3:1 OR STEEPER EROSION CONTROL BLANKET NORTH AMERICAN GREEN S75BN MATERIAL SPECIFICATIONS: ·EROSION CONTROL BLANKET SHALL BE A MACHINE-PRODUCED MAT OF 100% AGRICULTURAL STRAW. ·THE BLANKET SHALL BE OF CONSISTENT THICKNESS WITH THE STRAW EVENLY DISTRIBUTED OVER THE ENTIRE AREA OF THE MAT. THE BLANKET SHALL BE COVERED ON THE TOP SIDE WITH 100% BIODEGRADABLE WOVEN NATURAL ORGANIC FIBER NETTING HAVING AN APPROXIMATE 1/2" X 1" MESH AND BE SEWN TOGETHER WITH BIODEGRADABLE THREAD. ·STRAW EROSION CONTROL BLANKET SHALL BE S75BN AS MANUFACTURED BY NORTH AMERICAN GREEN, INC. (812-867-6632) OR EQUIVALENT. EROSION CONTROL BLANKET SHALL HAVE THE FOLLOWING PROPERTIES: MATERIAL CONTENT: ·STRAW: 100% (0.50 lbs/sq.yd.)(0.27 kg/m2) ·NETTING: ONE SIDE ONLY, LENO WOVEN 100% BIODEGRADABLE NATURAL ORGANIC FIBER (APPROX. WEIGHT 9.3 lbs./100 sq. ft.) ·THREAD: BIODEGRADABLE PHYSICAL SPECIFICATIONS (ROLL): ·WIDTH: 6.67 feet (2.03 m) ·LENGTH: 108 feet (32.92 m) ·WEIGHT: 46.4 lbs. ± 10% (21.05 kg) ·AREA: 80 sq. yd. (50 m2) THE HOMESTEAD SCHOOL 1233F Shelburne Road (VT Route 7) South Burlington, Vermont BLANK PROPERTY INFORMATION: ADDRESS: 1233F SHELBURNE ROAD PARCEL ID: 1540-1233F SPAN: 600-188-11945 GRANDLIST ACREAGE: 0.09 ACRES (CONDO) ZONING: COMMERCIAL 1 FRONT YARD BUILDING SETBACK: 30' BACK YARD BUILDING SETBACK: 30' SIDE YARD BUILDING SETBACK: 10' MAXIMUM BUILDING COVERAGE: 40% MAXIMUM TOTAL LOT COVERAGE: 70% PROPERTY OWNER/APPLICANT: REPERIO PROPERTIES, LLC C/O JEFF O'HARA P.O. BOX 1133 WILLISTON, VERMONT 05495 ISSUED FOR PERMIT REVIEW NOT FOR CONSTRUCTION C-2.02 DETAILS 164 Main Street, Suite 201 P: (802) 878-0375 Colchester, Vermont 05446 www.krebsandlansing.com STAMP: N.T.S. SCHEMATIC FENCE DETAIL DESIGNED AND INSTALLED BY FENCE CONTRACTOR NOTES N.T.S. INDIVIDUAL TREE PROTECTION FLAGGING - PROJECT DEMARCATION 1.PROTECT TREE ROOT SYSTEMS FROM DAMAGE CAUSED BY RUNOFF OR SPILLAGE OF NOXIOUS MATERIALS WHILE MIXING, PLACING, OR STORING CONSTRUCTION MATERIALS. PROTECT ROOT SYSTEMS FROM PONDING, ERODING, OR EXCESSIVE WETTING CAUSED BY DEWATERING OPERATIONS. 2.PROTECTION-ZONE FENCING: INSTALL PROTECTION-ZONE FENCING AT THE DRIP EDGE OF TREE, TO THE EXTENT PRACTICAL. APPROXIMATE DIAMETER DISTANCE SHOULD BE 1' PER EVERY INCH DIAMETER OF TREE DIAMETER MEASURED AT DBH (DIAMETER @ BREAST HEIGHT). INSTALL SILT FENCING OR APPROVED EQUAL ALONG EDGES OF PROTECTION ZONES. FENCING SHALL BE MAINTAINED THROUGHOUT CONSTRUCTION AND LIMIT FOOT AND VEHICLE TRAFFIC NEAR TREE. 3.PRUNE ROOTS THAT ARE AFFECTED BY TEMPORARY AND PERMANENT CONSTRUCTION. ROOT PRUNING SHALL ONLY BE DONE IF ABSOLUTELY NECESSARY, AVOID TO THE EXTENT PRACTICAL. PRUNE ROOTS AS FOLLOWS: ·CUT ROOTS MANUALLY BY DIGGING A TRENCH AND CUTTING EXPOSED ROOTS WITH SHARP PRUNING INSTRUMENTS: DO NOT BREAK, TEAR, CHOP OR SLANT THE CUTS. DO NOT USE A BACKHOE OR OTHER EQUIPMENT THAT RIPS, TEARS OR PULLS ROOTS. ·CUT ENDS: DO NOT PAINT CUT ROOT ENDS ·TEMPORARILY SUPPORT AND PROTECT ROOTS FROM DAMAGE UNTIL T HEY ARE PERMANENTLY REDIRECTED AND COVERED WITH SOIL. ·COVER EXPOSED ROOTS WITH BURLAP AND WATER REGULARLY. ·BACKFILL AS SOON AS POSSIBLE. 4.CROWN PRUNE BRANCHES THAT ARE AFFECTED BY TEMPORARY AND PERMANENT CONSTRUCTION. CROWN PRUNING SHALL ONLY BE DONE IF ABSOLUTELY NECESSARY, AVOID TO THE EXTENT PRACTICAL. PRUNE BRANCHES AS FOLLOWS: ·PRUNE TREES TO REMAIN TO COMPENSATE FOR ROOT LOSS CAUSED BY DAMAGING OR CUTTING ROOT SYSTEM. PROVIDE SUBSEQUENT MAINTENANCE DURING CONTRACT PERIOD AS RECOMMENDED BY ARBORIST. ·PRUNING STANDARDS: PRUNE TREES ACCORDING TO ANSI A300 (PART1). ·CUT BRANCHES WITH SHARP PRUNING INSTRUMENTS; DO NOT BREAK OR CHOP. ·DO NOT APPLY PRUNING PAINT TO WOUNDS. 5.WHERE NEW FINISH GRADE IS INDICTED BELOW EXISTING GRADE AROUND TREES, SLOPE GRADE BEYOND THE PROTECTION ZONE. MAINTAIN EXISTING GRADES WITHIN THE PROTECTION ZONE TO THE EXTENT PRACTICAL. 6.WHERE NEW FINISH GRADE IS INDICATED ABOVE EXISTING GRADE AROUND TREES, SLOPE GRADE BEYOND THE PROTECTION ZONE. MAINTAIN EXISTING GRADES WITHIN THE PROTECTION ZONE TO THE EXTENT PRACTICAL. 7.CONTRACTOR FAILS TO ENFORCE TREE PROTECTION MEASURES, RESULTING IN DAMAGE AND LOSS OF TREE(S), CONTRACTOR SHALL REPLACE TREE(S) WITH A 4" CALIPER SUBSTITUTE AT THE CONTRACTORS EXPENSE. PROTECTIVE ZONE FENCING. FENCING WILL BE SILT FENCE, SNOW FENCE OR APPROVED EQUAL. EXISTING TREE TO BE PROTECTED WODDEN STAKES, 10' MAXIMUM SPACING BETWEEN STAKES, SEE SILT FENCE DETAIL FOR ADDITIONAL INFORMATION. EXISTING GRADE CONTRACTOR MAY ADD MULCH OR SILT SOXX AROUND PROTECTIVE ZONE FENCING FOR ADDITIONAL PROTECTION. THE HOMESTEAD SCHOOL 1233F Shelburne Road (VT Route 7) South Burlington, Vermont PROPERTY INFORMATION: ADDRESS: 1233F SHELBURNE ROAD PARCEL ID: 1540-1233F SPAN: 600-188-11945 GRANDLIST ACREAGE: 0.09 ACRES (CONDO) ZONING: COMMERCIAL 1 FRONT YARD BUILDING SETBACK: 30' BACK YARD BUILDING SETBACK: 30' SIDE YARD BUILDING SETBACK: 10' MAXIMUM BUILDING COVERAGE: 40% MAXIMUM TOTAL LOT COVERAGE: 70% PROPERTY OWNER/APPLICANT: REPERIO PROPERTIES, LLC C/O JEFF O'HARA P.O. BOX 1133 WILLISTON, VERMONT 05495 1 BLUE SPACE OPEN = ±18.2 S.F. FENCE SPACE = ±17.6 S.F. POSTS SHALL EXTEND 5" HIGHER THAN THE TOP OF FENCE PANEL, SEE SCHEMATIC BELOW POSTS SHALL EXTEND 5" HIGHER THAN THE TOP OF FENCE PANEL, SEE SCHEMATIC BELOW FENCE PANEL WILL SIT 2" ABOVE EXISTING GRADE, SEE SCHEMATIC BELOW FENCE PANEL WILL SIT 2" ABOVE EXISTING GRADE, SEE SCHEMATIC BELOW N.T.S. DETAILS BY WEATHERABLES FENCING, CHELSEA STYLE VINYL PICKET FENCE N.T.S. SCHEMATIC FENCE OPAQUE CALCULATION FOR PROPOSED FENCE