Loading...
HomeMy WebLinkAboutSP-23-002 - Supplemental - 0200 Market Street (4)GYPSUM WALL BOARD SCHEDULE 1.WHERE METAL STUD AND GYPSUM WALL BOARD PARTITIONS ARE INDICATED ON THE DRAWINGS USE THE FOLLOWING TABLE IN CONJUNCTION WITH THE ROOM FINISH SCHEDULE TO DETERMINE THE TYPE OF GYPSUM WALL BOARD REQUIRED GYP BD1 ABUSE RESISTANCE/ ENHANCED CORE USE ON ALL INTERIOR WALLS OR WHERE NOTED (TO 10'-0" A.F.F.) GYP BD2 NON REINFORCED USE ON ALL INTERIOR WALLS FROM 10'-0" A.F.F. TO BOTTOM OF DECK UNLESS NOTED OTHERWISE, AND AT SOFFITS GYP BD3 WATER-RESISTANT USE IN ALL TOILET ROOMS, LOCKER ROOMS, KITCHENS AND OTHER AREAS WHICH ARE SUBJECT TO MODERATE AMOUNTS OF MOISTURE* GYP BD4 FLEXIBLE USE IN AREAS THAT REQUIRE CURVED WALLS OR SOFFITS, ETC. GYP BD5 EXTERIOR GYPSUM SHEATHING USE ON ALL EXTERIOR WALLS WITH METAL STUD BACK-UP GYP BD6 CEILING BOARD HARD CEILINGS (EXCEPT IN AREAS THAT WOULD OTHERWISE REQUIRE GYP BD3 OR GYP BD8 DUE TO MOISTURE*) GYP BD7 EXTERIOR CEILING BOARD EXTERIOR GYPSUM BOARD SOFFITS SHOWER AREAS AND OTHER HIGH MOISTURE AREAS* GYP BD8 CEMENTITIOUS BOARD ALL LOCATIONS BEHIND WALL TILE (WET OR DRY) GYP BD9 CEMENTITIOUS TILE BACKER BOARD *MODERATE AND HIGH MOISTURE AREAS SHALL BE AS DEFINED BY THE GYP BD MANUFACTURER FOR EACH TYPE OF BOARD. COORDINATE WITH MANUFACTURERS RECOMMENDED USES AND/OR MOISTURE LIMITATIONS. HINGE SIDE STRIKE SIDE NOTE: MINIMUM STRIKE SIDE DIMENSIONS TAKE PRECEDENCE AND CANNOT BE REDUCED. HINGE SIDE DIMENSIONS CAN BE REDUCED TO MAINTAIN MINIMUM STRIKE SIDE CLEARANCES. VERIFY THAT WALL FINISHES AND ACCESSORIES ALLOW FOR HINGE SIDE REDUCTION FACE OF STUD FACE OF STUD PUSH SIDE OF DOOR (TYP.) PULL SIDE OF DOOR (TYP.)TO FACE OF WALL 1'-2" (1'-0" MIN. W/FIN) 1'-8" (1-7" MIN. W/FIN) TO CMU 4" TO FACE OF STUD 4" FACE OF CMU PLAN DIM.PLAN DIM. TO FACE OF STUD 00 TYPICAL DIMENSION DETAIL 1" = 1'-0" SCALE TYPE 1 TYPE 2 (SECTION VIEW)(PLAN VIEW) NOTE: PROVIDE TYPE 1 BLOCKING FOR MARKER BOARDS, TACK BOARDS, WALL MOUNTED ACOUSTICAL/REFLECTOR PANELS, ETC NOTE: PROVIDE TYPE 2 BLOCKING FOR TOILET ACCESSORIES, WALL- MOUNTED TV MONITOR BRACKETS, RAILING BRACKETS, DOOR STOPS, WALL SHELVING, CASEWORK, WALL MOUNTED PROJECTORS, ETC. SCHEDULED WALL TYPE SCHEDULED WALL TYPE 6" X 16 GA. SHEET METAL STRAP OVER STUDS 5/8" FRT PLYWOOD WITH FLEXIBLE CONNECTOR PLATES AT METAL STUDS NON RATED 1 HR RATED SEPARATION (UL U419, OR EQUAL) MP MP1 MOISTURE-RESISTANT GYP. MP2 TYPICAL PARTITION GENERAL NOTES 1. ALL PARTITIONS SHALL EXTEND TO THE UNDERSIDE OF FLOOR FRAMING/METAL DECK OR BOTTOM OF TRUSS CHORDS ABOVE, UNLESS SPECIFICALLY INDICATED AS OTHERWISE ON DRAWINGS. ATTACHMENT OF NEW TOP OF WALL THROUGH EXISTING GYP. BD. WILL NOT BE ACCEPTABLE. 2. ACOUSTIC INSULATION SHALL BE PROVIDED IN ALL NON-FIRE RATED PARTITIONS AS INDICATED BY PARTITION TYPES. INSULATION SHALL EXTEND MINIMUM 6 INCHES ABOVE THE HIGHEST ADJACENT CEILING. INSULATION IN FIRE RATED PARTITIONS SHALL BE PROVIDED PER THE U.L. ASSEMBLY DETAILS INDICATED. 3. PROVIDE CONTROL JOINTS IN GYPSUM WALL BOARD PARTITIONS AT 30 FEET MAXIMUM SPACING, WHETHER OR NOT THE DRAWINGS DEPICT CONTROL JOINTS. LOCATE JOINTS AT TOP CORNERS OF DOOR AND BORROWED LIGHT FRAMES TO THE GREATEST EXTENT POSSIBLE. 4. WHERE GYP BD CONTROL JOINTS OCCUR AWAY FROM DOOR OR BORROWED LIGHT FRAMES, JOINTS SHALL EXTEND THE FULL HEIGHT OF THE FRAMED WALL, WHETHER OR NOT CONCEALED BY SURFACE INSTALLED EQUIPMENT OR APPLIED TREATMENTS, OR CEILINGS. 5. LINTELS SHALL BE PROVIDED AT OPENINGS IN MASONRY PARTITIONS FOR NEW OPENINGS, DOORS, WINDOWS, LOUVERS, RECESSED EQUIPMENT INCLUDING, BUT NOT LIMITED TO UNIT HEATERS, CONVECTORS, FIRE HOSE CABINETS, TOILET ACCESSORIES, AND DUCTWORK PENETRATIONS THAT ARE OVER 16 INCHES WIDE. PROVIDE STEEL LINTELS FOR OPENINGS UNLESS NOTED OTHERWISE. REFER TO STRUCTURAL DRAWINGS FOR STEEL LINTEL SCHEDULES AND TYPICAL DETAIL REQUIREMENTS. 6. ALL GAPS AT BUILDING JOINTS AND THROUGH-PENETRATIONS OF NON-FIRE RATED WALLS SHALL BE SEALED TO REDUCE NOISE TRANSFER. AT CONTRACTOR’S OPTION, PROVIDE ACOUSTIC FOAM INSULATION PER SECTION 07 21 19, OR PACK CONTINUOUS MINERAL WOOL INSULATION TO FILL GAPS TO FULL THICKNESS OF WALL. A VCT/ LIN/ RRT/ EPF (VCT SHOWN) REDUCING ADAPTER RESILIENT TRANSITION STRIP-BY SC-RESFL CONCRETE B VCT/RRT/OR LINOLEUM RESILIENT TRANSITION STRIP-BY CARPET INSTALLER CARPET C D PCT/CMT/ QT/MAT ALUMINUM TRANSITION STRIP-BY SC-TILE VCT/LIN/EPF/CONC. CONC. F CARPET RESILIENT TRANSITION STRIP- BY CARPET INSTALLER CONC. OR TERRAZZO PCT/CMT/QT/MAT ALUMINUM TRANSITION STRIP-BY SC-TILE PCT/CMT/QT CONC. 09 TYPICAL FLOORING TRANSITION DETAILS 1 1/2" = 1'-0" SCALE 6"8"STAIR 2 BRAILLE STAIR NAME TYPE C EXITEQ3 1/2"EQ5/8"1/4"5/8"1/4"1/4"SIGN TYPES LEGEND 1. ALL SIGN TYPE ELEVATIONS SHOWN AT 6"=1'-0" UNLESS NOTED OTHERWISE. 2. RAISED LETTERING AND BRAILLE TO BE "WHITE". 3.BACKGROUND PLACARD CONTRASTING COLOR TO BE SELECTED FROM FULL RANGE OF AVAILABLE STANDARD COLORS.6" EQ 8"BRAILLE ROOM NAME ROOM NAME TYPE B 8"8"A101 BRAILLE ROOM NUMBER AND NAME ROOM NAME TYPE A STORAGE ROOM NUMBER 1/2"3/4"5/8"3/4"5/8"5/8"1/4"1/2"1/4"1/4"5/8"RESTROOM TYPICAL ROOM SIGN USE AT LATRINES USE AT ALL CORRIDOR SIDE OF ALL STAIR DOORS 8"8"A101 BRAILLE ROOM NUMBER AND NAME TYPE D ELECTRIC 1/2"3/4"5/8"3/4"5/8"3/4"5/8"5/8"1/4"5/8"1/4"USE AT ELECTRIC, EMERGENCY ELECTRIC, AND MECHANICAL ROOMS ROOM NO STORAGE PERMITTED EQ 2" MATING WALL W/ (1) LAYER 7/16" GYP BD EA SIDE BY KBS MM NON RATED EXTERIOR 10" WALL W/ 7/16" ADVANTECH ZIP WALL SHEATHING BY KBS MX 1X3 PT STRAPPING AT 16" O.C. 6 1/4" CEMENT FIBER SIDING FIBER CEMENT SIDING OVER 6" WOOD FRAMING X1.10 CONT. VR/AIB 2 LAYERS 5/8" GYPSUM BOARD 2X6 FRAMING @ 16" O.C 2 LAYERS 5/8" GYPSUM BOARD 2 1/2" EPS INSULATION 1X3 PT STRAPPING AT 16" O.C. 6 1/4" CEMENT FIBER SIDING R-19 FIBERGLASS INSUL B/T STUDS TRUE NORTH PROJECT NORTH N PROJECT NUMBER: B D F H K M P R T V X 13579111315171921232527 COPYRIGHT ©2020 by Dore & Whittier Architects, Inc. (D+W). These documents are D+W's instruments of service and as such, D+W retains all copyrights, common law, and statutory rights. Use of these documents without D+W's express written permission will result in copyright infringement. 2468101214161820222426 135791113151719212325272468101214161820222426 A C E G J L N Q S U W B D F H K M P R T V X A C E G J L N Q S U W MASSACHUSETTS 260 MERRIMAC STREET BUILDING 7, 2ND FLOOR NEWBURYPORT, MA 01950 P: (802) 863-1428 P: (978) 499-2999 VERMONT 212 BATTERY STREET BURLINGTON, VT 05401 SEAL AND SIGNATURE: REVISIONS: ISSUE TITLE AND DATE: KEY PLAN ORIENTATION AND SCALE: SHEET TITLE: SHEET NUMBER:12/12/2022 9:18:01 PMAutodesk Docs://South Burlington Elementary School Study/ARCH - 823 - SB Orchard Elementary School.rvt21-0823 10.19.22 WALL TYPES, TYPICAL DETAILS, PARTITION NOTES AG.2 PROGRESS SET SOUTH BURLINGTON ES MODULARS MARCOTTE CENTRAL ELEMENTARY SCHOOL & ORCHARD ELEMENTARY SCHOOL 1" = 1'-0"2 TYPICAL DOOR OFFSETS (U.N.O) 1" = 1'-0"3 TYPICAL DIMENSION DETAIL 1" = 1'-0"5 TYPICAL BLOCKING DETAIL WALL TYPES LEGEND 1 1/2" = 1'-0"6 TYPICAL FLOORING TRANSISTION DETAILS NO. DATE TITLE EXT. WALL ASSEMBLY BY KBS; SEE SPECS.