HomeMy WebLinkAboutPermit Wastewater Allocation WWA-23-122CLASS II WETLAND (TYP)
WETLAND BUFFER (TYP)
50'
DORSET STREET
EXISTING
PROPERTYLINE
EXISTING
SEARS AUTOCENTER
EXISTING 8" D.I. WATER MAINEXISTING 4"
D.I. WATER
SERVICE
EXISTING 8"
SDR35 SEWER
SERVICE
EXISTING 8" D.I. WATER MAIN
PROFESSIONAL
SERVICES / RETAIL
(2,255 SF)
TENANT B
CASUAL RESTAURANT
(PRIMARILY TAKEOUT)
(1,677 SF)
TENANT D
HEALTH AND
WELLNESS RETAILER
(2,389 SF)
TENANT E
CASUAL RESTAURANT
(PRIMARILY TAKEOUT)
(1,656 SF)
TENANT F
CASUAL
RESTAURANT
(2,902 SF)
MECHANICAL
ROOM
(249 SF)COMMON CORRIDOR (1,081 SF)TENANT A
FITNESS
(2,615 SF)
22'
Drawing Title
Designed by
No.
of
Project Number
Sheet
Drawing Number
Drawing Title
Issued for
Checked byDesigned by
Appvd.DateRevisionNo.Saved Friday, March 24, 2023 3:49:17 PM DHEIL Plotted Monday, March 27, 2023 11:34:42 AM Dan Heil\\vhb.com\gbl\proj\SBurlington\58718.00 U Mall\cad\ld\Planset\Sears Auto Renovation\5871800-SP.dwg
vhb.comDate
40 IDX Dr
Building 100 Suite 200
South Burlington, VT 05403
802.497.6100
Multi-Tenant Building
225 Dorset Street
South Burlington, VT 05403
DRAFT
Not Approved for Construction
Mar. 17, 2023
1
58718.00
Feet40.000120010
Site Plan
C2.02
1
DJH DJH
Computations
Project:Multi-Tenant Building Project #:58718.00
Location:225 Dorset Street Sheet:
Calculated by:DJH Date:04/03/2023
Checked by: Date:
Title:Existing Water and Wastewater Allocation Calculations
Multi-Tenant Building
225 Dorset Street
Exisiting Water and Wastewater Allocations
Existing Water / Wastewater Allocation* Sears Auto
Quantity Unit
26 Employees 15 gpd/emp
*Based on the State Environmental Protection Rules, Chapter 1, Table 8‐3
Proposed Water / Wastewater Allocation* Multi‐Tenant Building
Quantity Unit
45 Seats 27 gpd/seat
1 Restaurant 300 gpd
2389 SF 4 4gpd/100 SF
1 Restaurant 300 gpd
2615 SF 4 4gpd/100 SF
10 Employees 15 gpd/emp
*Based on the State Environmental Protection Rules, Chapter 1, Table 8‐3
300
96
300
105
150
Increase In Demand 1776
390
Use Design Flow (gpd)
Restaurant (2 Meals / Day)1215
Demand
Total
2166
Restaurant (less than 9 seats)
Retail
Professional Services
Restaurant (less than 9 seats)
Retail
Total
Use Design Flow (gpd)
Automotive Repair 390
Demand
1A3002A300Common / Mech / Fire Pump/ Elec / TelecomCommon CorridorProposed Financial InstitutionTenant ATenant BTenant CTenant DTenant ETenant F2,389 SFTenant D2,255 SFProposedFinancialInstitution249 SFCommon /Mech / FirePump / Elec /Telecom1,677 SFTenant B1,656 SFTenant E2,902 SFTenant F1,081 SFCommonCorridor8'-0"34'-2 3/4"18'-9 3/4" 28'-5 1/4" 19'-8 3/4" 36'-5" 31'-11 3/4"4'-4 1/2"84'-8"12'-0"12'-0"L O A D I N GD O R S E T S T R E E TNEW LANDINGTYPICAL2,615 SFTenant ASCALEDATE1/16" = 1'-0"A101University MallSouth Burlington, VTSears Auto Center Building03/06/2023PLAN--0'16'32'8'NCasualRestaurant - 2meals per day(45 seats)CasualRestaurant -PrimarilyTakeout (lessthan 9 seats)CasualRestaurant -PrimarilyTakeout (lessthan 9 seats)RetailProfessionalServices w/ 10employeesRetail