Envelope Compliance Certificate
Project Title:
2020 Vermont Commercial Building Energy Standards
Project Type:Addition
Vertical Glazing / Wall Area:38%
Location:Burlington, Vermont
Climate Zone:6a
Construction Site:
1795 Shelburne Road
South Burlington, Vermont 05819
Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Mazda South Burlington
Building Area Floor Area
1-addition (Automotive Facility) : Nonresidential 2220
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - addition]2113 ---40.0 0.025 0.025
Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - addition]5574 ---30.0 0.032 0.025
Floor: Unheated Slab-On-Grade, Vertical 3 ft., [Bldg. Use 1 -
addition] (c)
175 ---10.0 0.510 0.480
NORTH
Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]2162 13.0 15.0 0.043 0.044
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.:
Product ID Kawneer 451 UT, SHGC 0.35, [Bldg. Use 1 -
addition] (b)
930 ------0.330 0.290
Door: Glass (over 50% glazing): Metal Frame, Entrance Door,
Perf. Specs.: Product ID Kawneer 350, SHGC 0.24, [Bldg. Use 1
- addition] (b)
113 ------0.670 0.680
EAST
Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]646 13.0 15.0 0.043 0.044
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.:
Product ID Kawneer 451 UT, SHGC 0.35, [Bldg. Use 1 -
addition] (b)
415 ------0.330 0.290
Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]1507 13.0 15.0 0.043 0.044
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.:
Product ID Kawneer 451 UT, SHGC 0.35, [Bldg. Use 1 -
addition] (b)
485 ------0.330 0.290
Door: Glass (over 50% glazing): Metal Frame, Entrance Door,
Perf. Specs.: Product ID Kawneer 350, SHGC 0.24, [Bldg. Use 1
- addition] (b)
42 ------0.670 0.680
SOUTH
Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]1307 13.0 15.0 0.043 0.044
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.:
Product ID Kawneer 451 UT, SHGC 0.35, [Bldg. Use 1 -
addition] (b)
245 ------0.330 0.290
Door: Glass (over 50% glazing): Metal Frame, Entrance Door,
Perf. Specs.: Product ID Kawneer 350, SHGC 0.24, [Bldg. Use 1
21 ------0.670 0.680
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
91 ofPage
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
- addition] (b)
WEST
Ext. Wall: Steel-Framed, 16in. o.c., [Bldg. Use 1 - addition]533 13.0 15.0 0.043 0.044
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.:
Product ID Kawneer 451UT, SHGC 0.35, [Bldg. Use 1 -
addition] (b)
60 ------0.330 0.290
Door: Glass (over 50% glazing): Metal Frame, Entrance Door,
Perf. Specs.: Product ID Kawneer 350, SHGC 0.24, [Bldg. Use 1
- addition] (b)
48 ------0.670 0.680
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Project Notes
Building consists of an addition, as well as envelope improvements to the existing showroom. All new
envelope components meet the prescriptive code requirements of Table 402.1 for the individual components.
Envelope FAILS: Design 10% worse than code
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
92 ofPage
Inspection Checklist
Requirements: 28.0% were addressed directly in the COMcheck software
COMcheck Software Version COMcheckWeb
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2020 Vermont Commercial Building Energy Standards
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR1]1
Plans and/or specifications provide all
information with which compliance
can be determined for the building
envelope and document where
exceptions to the standard are
claimed.
Complies
Does Not
Not Observable
Not Applicable
C402.3.1
[PR10]1
The vertical fenestration area <= 30
percent of the gross above-grade wall
area.
Complies
Does Not
Not Observable
Not Applicable
C402.3.1
[PR11]1
The skylight area <= 3 percent of the
gross roof area.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
93 ofPage
Section
#
& Req.ID
Footing / Foundation Inspection Complies?Comments/Assumptions
C303.2
[FO4]2
Slab edge insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[FO6]1
Exterior insulation protected against
damage, sunlight, moisture, wind,
landscaping and equipment
maintenance activities.
Complies
Does Not
Not Observable
Not Applicable
C104
[FO3]2
Installed slab-on-grade insulation type
and R-value consistent with insulation
specifications reported in plans and
COMcheck reports.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[FO12]3
Radiant heating systems panels
insulated to >=R-3.5 on face opposite
space being heated.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
Location on plans/spec: n/a
See the Envelope Assemblies table for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
94 ofPage
Section
#
& Req.ID
Framing / Rough-In Inspection Complies?Comments/Assumptions
C303.1.3
[FR12]2
Fenestration products rated in
accordance with NFRC.
Complies
Does Not
Not Observable
Not Applicable
C303.1.3
[FR13]1
Fenestration products are certified as
to performance labels or certificates
provided.
Complies
Does Not
Not Observable
Not Applicable
C402.4.1.
5,
C402.4.1.
7
[FR18]3
Factory-built fenestration and doors
are labeled as meeting air leakage
requirements.
Complies
Does Not
Not Observable
Not Applicable
C402.3.3
[FR10]1
Vertical fenestration SHGC value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.3.3,
C402.3.3.
4
[FR8]1
Vertical fenestration U-Factor.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.1.
7
[FR14]2
U-factor of opaque doors associated
with the building thermal envelope
meets requirements.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.5
[FR17]3
Vestibules are installed on all building
entrances. Doors have self-closing
devices. Vestibule space heat
tempering limited to 55°F and
thermostatically (programmable only)
controlled as separate zone.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
95 ofPage
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies?Comments/Assumptions
C402.4.3,
C403.7.7
[ME58]3
Outdoor air and exhaust systems have
motorized dampers that automatically
shut when not in use and meet
maximum leakage rates. Check
gravity dampers where allowed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
96 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.6
[EL26]2
Low-voltage dry-type distribution
electric transformers meet the
minimum efficiency requirements of
Table C405.6.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
Location on plans/spec: n/a
C405.7
[EL27]2
Electric motors meet the minimum
efficiency requirements of Tables
C405.7(1) through C405.7(4).
Efficiency verified through certification
under an approved certification
program or the equipment efficiency
ratings shall be provided by motor
manufacturer (where certification
programs do not exist).
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: Products were reviewed during
submittal phase of construction
C405.8.2,
C405.8.2.
1
[EL28]2
Escalators and moving walks comply
with ASME A17.1/CSA B44 and have
automatic controls configured to
reduce speed to the minimum
permitted speed in accordance with
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.9
[EL29]2
Total voltage drop across the
combination of feeders and branch
circuits <= 5%.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: E001, Electrical Notes Part 3, C2
C405.10
[EL30]2
New parking lots with occupancy
groups in Table 405.11 shall provide
electric vehicle parking spaces
including cabinet, box or enclosure to
a conduit linking parking space with
electrical service.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec: E101
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
97 ofPage
Section
#
& Req.ID
Insulation Inspection Complies?Comments/Assumptions
C303.1.1
[IN3]1
Roof insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.1
[IN10]2
Building envelope insulation is labeled
with R-value or insulation certificate
providing R-value and other relevant
data.
Complies
Does Not
Not Observable
Not Applicable
C303.2
[IN7]1
Above-grade wall insulation installed
per manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[IN14]2
Exterior insulation is protected from
damage with a protective material.
Verification for exposed foundation
insulation may need to occur during
Foundation Inspection.
Complies
Does Not
Not Observable
Not Applicable
C402.2.1
[IN17]3
Insulation intended to meet the roof
insulation requirements cannot be
installed on top of a suspended
ceiling. Mark this requirement
compliant if insulation is installed
accordingly.
Complies
Does Not
Not Observable
Not Applicable
C104
[IN6]1
Installed above-grade wall insulation
type and R-value consistent with
insulation specifications reported in
plans and COMcheck reports.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C104
[IN8]2
Installed floor insulation type and R-
value consistent with insulation
specifications reported in plans and
COMcheck reports.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[IN18]3
Radiant panels and associated
components, designed for heat
transfer from the panel surfaces to the
occupants or indoor space are
insulated with a minimum of R-3.5.
Complies
Does Not
Not Observable
Not Applicable
C402.4.1.
3
[IN1]1
All sources of air leakage in the
building thermal envelope are sealed,
caulked, gasketed, weather stripped
or wrapped with moisture vapor-
permeable wrapping material to
minimize air leakage.
Complies
Does Not
Not Observable
Not Applicable
C104
[IN2]1
Installed roof insulation type and R-
value consistent with insulation
specifications reported in plans and
COMcheck reports. For some ceiling
systems, verification may need to
occur during Framing Inspection.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
98 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C402.4.1.
7
[FI37]1
Weatherseals installed on all loading
dock cargo doors.
Complies
Does Not
Not Observable
Not Applicable
C408.1.1
[FI63]1
Building operations and maintenance
documents will be provided to the
owner. Documents will cover
manufacturers' information,
specifications, programming
procedures and means of illustrating
to owner how building, equipment and
systems are intended to be installed,
maintained, and operated.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Mazda South Burlington 01/13/23Report date:
99 ofPage
COMcheck Software Version 4.1.5.3
Interior Lighting Compliance Certificate
Project Title:
2020 Vermont Commercial Building Energy Standards
Project Type:New Construction
Construction Site:Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Autosaver Mazda
Credits: 6.0 Required 7.0 Proposed
High Efficiency HVAC - C406.2, 3.0 credit
Reduced Lighting Power - C406.3.1, 4.0 credit
Additional Efficiency Package(s)
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-Car Sales (Common Space Types:Sales Area)10000 0.89 8880
8900Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
1-Car Sales (Common Space Types:Sales Area)
A: Other:1 8 72 576
A2: Other:1 2 74 148
C: Other:1 9 20 180
D: Other:1 48 44 2112
F: Other:1 39 30 1170
G: Other:1 2 10 20
H: Other:1 4 49 196
J: Other:1 78 42 3276
L: Other:1 2 24 48
M: Other:1 6 22 132
P: Other:1 2 30 60
7918Total Proposed Watts =
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2020 Vermont Commercial Building Energy Standards requirements in COMcheck Version 4.1.5.3 and to
comply with any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES: Design 11% better than code
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
121 ofPage
COMcheck Software Version 4.1.5.3
Mechanical Compliance Certificate
Project Title:
2020 Vermont Commercial Building Energy Standards
Project Type:New Construction
Location:South Burlington, Vermont
Climate Zone:6a
Construction Site:Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Autosaver Mazda
Credits: 6.0 Required 7.0 Proposed
High Efficiency HVAC - C406.2, 3.0 credit
Reduced Lighting Power - C406.3.1, 4.0 credit
Additional Efficiency Package(s)
Mechanical Systems List
Quantity System Type & Description
Cooling: 1 each - Single Package Vertical AC Unit, Capacity = 60 kBtu/h, Air-Cooled Condenser, Unknown Economizer
Proposed Efficiency = 12.00 EER, Required Efficiency: 10.35 EER
Fan System: None
3 HVAC System 1 (Single Zone):
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the 2020 Vermont Commercial Building Energy Standards requirements in COMcheck Version 4.1.5.3 and to
comply with any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
122 ofPage
Inspection Checklist
Requirements: 0.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.1.5.3
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2020 Vermont Commercial Building Energy Standards
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR2]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the mechanical
systems and equipment and
document where exceptions to the
standard are claimed. Load
calculations per acceptable
engineering standards and
handbooks.
Complies
Does Not
Not Observable
Not Applicable
C103.2
[PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
123 ofPage
Section
#
& Req.ID
Footing / Foundation Inspection Complies?Comments/Assumptions
C403.2.4.
5,
C403.2.4.
6
[FO9]3
Snow/ice melting system sensors for
future connection to controls. Freeze
protection systems have automatic
controls installed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
124 ofPage
Section
#
& Req.ID
Plumbing Rough-In Inspection Complies?Comments/Assumptions
C404.5,
C404.5.1,
C404.5.2
[PL6]3
Heated water supply piping conforms
to pipe length and volume
requirements. Refer to section details.
Complies
Does Not
Not Observable
Not Applicable
C404.6.3
[PL7]3
Pumps that circulate water between a
heater and storage tank have controls
that limit operation from startup to
<= 5 minutes after end of heating
cycle.
Complies
Does Not
Not Observable
Not Applicable
C404.7
[PL8]3
Demand recirculation water systems
have controls that start the pump
upon receiving a signal from the
action of a user of a fixture or
appliance and limits the temperature
of the water entering the cold-water
piping to 104°F.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
125 ofPage
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies?Comments/Assumptions
C402.2.6
[ME41]3
Thermally ineffective panel surfaces of
sensible heating panels have
insulation >= R-3.5.
Complies
Does Not
Not Observable
Not Applicable
C403.2.3
[ME118]1
Building heating with electrical
resistance units, including baseboard
radiation, heat pump reheat coils,
duct coils, boilers, domestic hot water
heaters, outdoor air intake grids, and
coils in terminal units and air systems,
prohibited.
Complies
Does Not
Not Observable
Not Applicable
C403.8.1
[ME65]3
HVAC fan systems at design
conditions do not exceed allowable
fan system motor nameplate hp or fan
system bhp.
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list for values.
C403.8.3
[ME117]2
Fans have efficiency grade (FEG) >=
67. The total efficiency of the fan at
the design point of operation <= 15%
of maximum total efficiency of the
fan.
Complies
Does Not
Not Observable
Not Applicable
C403.2.13
[ME71]2
Unenclosed spaces that are heated
use only radiant heat. Electric
resistance heating is prohibited for
heating spaces outside a building.
Complies
Does Not
Not Observable
Not Applicable
C403.2.3
[ME55]2
HVAC equipment efficiency verified.Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list for values.
C403.2.6.
1
[ME59]1
Demand control ventilation provided
for spaces >500 ft2 and >25
people/1000 ft2 occupant density and
served by systems with air side
economizer, auto modulating outside
air damper control, or design airflow
>3,000 cfm.
Complies
Does Not
Not Observable
Not Applicable
C403.7.2
[ME115]3
Enclosed parking garage ventilation
has automatic contaminant detection
and capacity to stage or modulate
fans as stipulated in the Vermont Fire
and Building Safety Code.
Complies
Does Not
Not Observable
Not Applicable
C403.7.5
[ME116]3
Kitchen exhaust systems comply with
replacement air and conditioned
supply air limitations, and satisfy hood
rating requirements and maximum
exhaust rate criteria.
Complies
Does Not
Not Observable
Not Applicable
C403.2.9
[ME60]2
HVAC ducts and plenums insulated.
Where ducts or plenums are installed
in or under a slab, verification may
need to occur during Foundation
Inspection. Ducts, air handlers and
filter boxes shall be sealed. Joints and
seams shall comply with Section 603.9
of the International Mechanical Code.
Complies
Does Not
Not Observable
Not Applicable
C403.2.9
[ME10]2
Ducts and plenums sealed based on
static pressure and location.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
126 ofPage
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies?Comments/Assumptions
C403.2.9.
1.3
[ME11]3
Ductwork operating >3 in. water
column requires air leakage testing.
Complies
Does Not
Not Observable
Not Applicable
C403.6.6
[ME110]3
Multiple zone VAV systems with DDC
of individual zone boxes have static
pressure setpoint reset controls.
Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
127 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.2.
2
[EL15]1
Lighting controls installed to uniformly
reduce the lighting load by at least
50%.
Complies
Does Not
Not Observable
Not Applicable
C405.2.1
[EL18]1
Occupancy sensors installed in
classrooms/lecture/training rooms,
conference/meeting/multipurpose
rooms, copy/print rooms,
lounges/breakrooms, enclosed offices,
open plan office areas, restrooms,
storage rooms, locker rooms,
warehouse storage areas, and other
spaces <= 300 sqft that are enclosed
by floor-to-ceiling height partitions.
Reference section language
C405.2.1.2 for control function in
warehouses and section C405.2.1.3
for open plan office spaces.
Complies
Does Not
Not Observable
Not Applicable
C405.2.1,
C405.2.1.
1,
C405.2.1.
3
[EL23]2
Occupancy sensors installed in
classrooms/lecture/training rooms,
conference/meeting/multipurpose
rooms, copy/print rooms,
lounges/breakrooms, enclosed offices,
open plan office areas, restrooms,
storage rooms, locker rooms,
warehouse storage areas, and other
spaces <= 300 sqft that are enclosed
by floor-to-ceiling height partitions.
Reference section language
C405.2.1.2 for control function in
warehouses and section C405.2.1.3
for open plan office spaces.
Complies
Does Not
Not Observable
Not Applicable
C405.2.2,
C405.2.2.
1,
C405.2.2.
2
[EL22]2
Each area not served by occupancy
sensors (per C405.2.1) have time-
switch controls and functions detailed
in sections C405.2.2.1 and C405.2.2.2.
Complies
Does Not
Not Observable
Not Applicable
C405.2.3
[EL16]2
Daylight zones provided with
individual controls that control the
lights independent of general area
lighting.
Complies
Does Not
Not Observable
Not Applicable
C405.2.3,
C405.2.3.
1,
C405.2.3.
2
[EL20]1
Daylight zones provided with
individual controls that control the
lights independent of general area
lighting. See code section C405.2.3
Daylight-responsive controls for
applicable spaces, C405.2.3.1 Daylight
responsive control function and
section C405.2.3.2 Sidelit zone.
Complies
Does Not
Not Observable
Not Applicable
C405.2.4
[EL4]1
Separate lighting control devices for
specific uses including display/accent
lighting, task lighting, nonvisual
purposes, and hotel/motel lighting
occpancy override switching.
Complies
Does Not
Not Observable
Not Applicable
C405.2.4
[EL8]1
Additional interior lighting power
allowed for special functions
automatically controlled and
separated from general lighting with
dedicated and independent controls.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
128 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.6
[EL26]2
Low-voltage dry-type distribution
electric transformers meet the
minimum efficiency requirements of
Table C405.6.
Complies
Does Not
Not Observable
Not Applicable
C405.7
[EL27]2
Electric motors meet the minimum
efficiency requirements of Tables
C405.7(1) through C405.7(4).
Efficiency verified through certification
under an approved certification
program or the equipment efficiency
ratings shall be provided by motor
manufacturer (where certification
programs do not exist).
Complies
Does Not
Not Observable
Not Applicable
C405.8.2,
C405.8.2.
1
[EL28]2
Escalators and moving walks comply
with ASME A17.1/CSA B44 and have
automatic controls configured to
reduce speed to the minimum
permitted speed in accordance with
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
Complies
Does Not
Not Observable
Not Applicable
C405.9
[EL29]2
Total voltage drop across the
combination of feeders and branch
circuits <= 5%.
Complies
Does Not
Not Observable
Not Applicable
C405.10
[EL30]2
New parking lots with occupancy
groups in Table 405.11 shall provide
electric vehicle parking spaces
including cabinet, box or enclosure to
a conduit linking parking space with
electrical service.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
129 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C303.3
[FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
C303.3
[FI8]3
Furnished O&M manuals for HVAC
systems within 90 days of system
acceptance.
Complies
Does Not
Not Observable
Not Applicable
C403.2.2
[FI27]3
HVAC systems and equipment
capacity does not exceed calculated
loads.
Complies
Does Not
Not Observable
Not Applicable
C403.4.1
[FI47]3
Heating and cooling to each zone is
controlled by a thermostat control.
Minimum one humidity control device
per installed
humidification/dehumidification
system.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
1.2
[FI38]3
Thermostatic controls have a 5 °F
deadband.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
1.3
[FI20]3
Temperature controls have setpoint
overlap restrictions.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
2
[FI39]3
Each zone equipped with setback
controls using automatic time clock or
programmable control system.
Complies
Does Not
Not Observable
Not Applicable
C403.2.4.
2.1,
C403.2.4.
2.2
[FI40]3
Automatic Controls: Setback to 55°F
(heat) and 85°F (cool); 7-day clock, 2-
hour occupant override, 10-hour
backup
Complies
Does Not
Not Observable
Not Applicable
C405.3.1
[FI18]1
Interior installed lamp and fixture
lighting power is consistent with what
is shown on the approved lighting
plans, demonstrating proposed watts
are less than or equal to allowed
watts.
Complies
Does Not
Not Observable
Not Applicable
See the Interior Lighting fixture schedule for values.
C407.2
[FI28]1
Commissioning plan developed by
registered design professional or
approved agency.
Complies
Does Not
Not Observable
Not Applicable
C404.11
[FI62]1
Service water heating systems,
swimming pool/spa water heating
systems with all controls shall be
commissioned in accordance with
Section 407.2.
Complies
Does Not
Not Observable
Not Applicable
C407.3.2
[FI31]1
HVAC equipment has been tested to
ensure proper operation including
economizers, VAV fan controls, part
load hydronic controls, and lighting
control systems.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
1210 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C408.1.1
[FI63]1
Building operations and maintenance
documents will be provided to the
owner. Documents will cover
manufacturers' information,
specifications, programming
procedures and means of illustrating
to owner how building, equipment and
systems are intended to be installed,
maintained, and operated.
Complies
Does Not
Not Observable
Not Applicable
C407.3.4
[FI29]1
Commissioning report completed and
certified by registered design
professional or approved agency.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
1211 ofPage
Project Title:
Data filename:
Autosaver Mazda
L:\Dropbox (Promus)\Promus Projects\2021\2021-0117 Autosaver Mazda (South Burlington,
VT)\01. Calcs\COMcheck\AutosaverMazdaCOMcheck.cck
12/17/21Report date:
1212 ofPage