HomeMy WebLinkAboutSP-22-060 - Supplemental - 0339 Garden Street (50)1
Betsy Brown
From:Monika Ingalls <moingalls@southburlingtonvt.gov>
Sent:Friday, January 27, 2023 1:46 PM
To:Andy Rowe
Subject:RE: 'EXTERNAL'RE: Catamount Run - Block B / #SP-22-060
SnyderHomes Security Filter
Warning: Sender moingalls@southburlingtonvt.gov is not yet trusted by your organization.
Please be careful before replying or clicking on the URLs.
powered by Graphus®
Hi Andy,
I believe you’ve addressed all of our comments, I’m just confirming with others in my department that there are no
further questions.
Thanks,
Monika Ingalls
Stormwater Project Manager
Department of Public Works
City of South Burlington
104 Landfill Road
South Burlington, VT 05403
(802) 658-7961 Ext. 6108
Notice - Under Vermont’s Public Records Act, all e-mail, e-mail attachments as well as paper copies of documents received or prepared for use in matters concerning
City business, concerning a City official or staff, or containing information relating to City business are likely to be regarded as public records which may be inspected
by any person upon request, unless otherwise made confidential by law. If you have received this message in error, please notify us immediately by return email.
Thank you for your cooperation.
2
From: Andy Rowe <arowe@snyderhomesvt.com>
Sent: Friday, January 27, 2023 10:33 AM
To: Monika Ingalls <moingalls@southburlingtonvt.gov>
Subject: 'EXTERNAL'RE: Catamount Run - Block B / #SP-22-060
This message has originated from an External Source. Please use proper judgment and caution when opening
attachments, clicking links, or responding to this email.
Hi Monika –
I wanted to follow-up on the EPSC Plan edits for Block B at City Center. With Marla Keene returning from vacation, on
Monday I am planning to provide responses and revised plans to address all of the comments she provided. If you have
any comments on the revised EPSC Plans – or they are acceptable as is, please let me know.
Thank you
Andy Rowe | PROJECT ENGINEER
SNYDER HOMES | SnyderHomesVT.com | 802.985.5722
From: Andy Rowe
Sent: Wednesday, January 25, 2023 8:15 AM
To: moingalls@southburlingtonvt.gov
Subject: Catamount Run - Block B / #SP-22-060
Hi Monika –
Marla passed on comments related to EPSC for Block B at City Center. Below are the responses, as well as the revised
plans attached. The responses are short, since the information is intended to be on the plans so that it gets
implemented in the field. I’d be happy to talk about any thoughts or comments you have.
1. Please revise the plans to specify where/how will dewatering occur.
Sheets 5 & 8 have been revised to include dewatering specifications and details. Dewatering discharge will be
conveyed to the opposite side of Market Street using existing 3” sleeves. Filter bags and/or overland flow will
be used to manage the discharge, which will flow to a stone lined sump and pipe that flows into the storm
pond. The stone lined sump and pipe are being installed now for a temporary use (panelizing structure) and
gravel storage area adjacent to the storm pond.
3
2. Please coordinate with the Department of Public Works to specify a type of inlet protection to be utilized in
Market Street that is more than a piece of fabric under a storm drain grate, but not something that would be
problematic for the traveling public (e.g. inlet protection involving stone piled around the grate).
The inlet protection detail on sheet 8 has been revised to include silt sacks for use on Garden Street and Market
Street.
3. Please revise the plans to include discussion of the additional EPSC related measures and BMPs that are required
during the winter construction season.
Winter EPSC Plan Requirements have been added to sheet 5.
Marla is on vacation this week, so I’m sending these directly to you to review in her absence. I will still provide the
responses and revised plans prior to her return by Monday January 30. I’ve marked the plans ‘draft’ only to avoid
multiple revision blocks in case there are any edits needed. If the plans are OK as is, I will remove the ‘draft’ and provide
them to Marla.
Please let me know if the revised plans address the comments, or if you have any questions.
Thanks,
Andy Rowe | PROJECT ENGINEER
SNYDER HOMES | SnyderHomesVT.com | 802.985.5722