HomeMy WebLinkAboutZP-23-043 - 0031 Swift Street 2/2/2023DDDDDDOHOHOHOHOHOHOHOH
OH
OH
UPUPUPUPUPUPUPUP21
3
214
2
1
6 217213214212211215216214
2
1
2
213
21
1
216217213215212210214213211212210210212211213215217216214208209218219210211213212216214218217210209209210211212208N/F
764 SHELBURNE RD. LLC,
C/O GARY BOURNE
N/F
GARY BOURNE
N/F
TKHS LLC
N/F
LEE THERESA M LIVING
TRUST, C/O DUFF AND PHELPS
N/F
GARY J. BOURNE
N/F
HANDY MOUNTAHA TRUST
1-STORY
BUILDING
2300 SQ. FT.
GAS CANOPY
1929 SQ. FT.
1-STORY
BUILDING
2812 SQ. FT.
1-STORY
BUILDING
6157 SQ. FT.
1-STORY
BUILDING
1-STORY
BUILDING
RAMP
PAVED DRIVE
PAVED DRIVE
PAVED DRIVESHELBURNE ROAD (U.S. ROUTE 7)SWIFT STREET
SHED
D D D D D D D D D D D
D
D D
D D D
D D
DD
WASTE OIL TANK
CONCRETE PAD WITH
TANK ACCESS WELLS
TRANSFORMER ON
CONCRETE PAD
D
D
D
D
D
RIM = 209.0
18" RCP iIN(E) = 202.2
18" RCP iIN(S) =201.3
18" RCP IOUT(W) = 200.6
116'±137'±122'±140'±118'±79'±7'±45'±125'±56'±
76'±99'±239'±
RIM = 210.8
15" RCP iIN(N) = 204.1
12" RCP iIN(E) =204.3
18" RCP iOUT(W) = 203.9
1-STORY
BUILDING
APPROX. LOCATION
EX. 8" WATER MAIN
(TO BE VERIFIED)
APPROX. LOCATION
EX. 6" WATER MAIN
(TO BE VERIFIED)
CROSSWALK SIGNAL
POLE
LEGAL LOAD
LIMIT SIGN
GAS
METER
UTILITY
COVER
SILT FENCE TO
TERMINATE AT EDGE
OF CONSTRUCTION
ENTRANCES
SOIL STOCKPILE (TYP.)
LOCATION SHOWN FOR ILLUSTRATIVE
PURPOSES AND SUBJECT TO CHANGE
DURING CONSTRUCTION
EXISTING BUILDING,
CURBING, & ASSOCIATED
STRUCTURE TO BE REMOVED
EXISTING
BUILDING,
CURBING, &
ASSOCIATED
STRUCTURE TO BE
REMOVED
EXISTING BUILDING,
CURBING, & ASSOCIATED
STRUCTURE TO BE REMOVED
EXISTING BUILDING,
CURBING, & ASSOCIATED
STRUCTURE TO BE REMOVED
CHAINLINK
CONSTRUCTION
FENCE AROUND
PERIMETER OF SITE
AT PROPERTY LINE
STABILIZED CONSTRUCTION ENTRANCE
24' WIDE X 30' LONG MINIMUM
CONSTRUCTION ENTRANCE (TYP.)
SILT FENCE TO BE INSTALLED
AROUND PERIMETER OF
PROJECT SITE SCESCE
SCE
CONCRETE FOOTING
FOR ROUTE 7
OVERHEAD LANE
ASSIGNMENT SIGN
RIM = 207.9
SUMP = 203.1
18" RCP iOUT +/- 202.7
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
TO BE REMOVED
ALL OVERHEAD
UTILITIES TO BE
REMOVED
ALL EXISTING TREES
AND VEGETATION
TO BE REMOVED
ALL EXISTING
UNDERGROUND
UTILITIES TO BE
REMOVED
GAS STATION SIGN
ROAD WORK SIGN
RIM = 207.5
CLOGGED
RIM = 213.1
12" CMP iOUT(W) = 208.6
TO BE REMOVED
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
ENGINEERING SURVEY
No. 8917
CIVILP
ROF
E
SSIONAL E N G INEERLICEN S E DJENNIFER ANN DESA
U
T
E
LSSTA TE O F VER
M
ONTField Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLAN NING ENVIRON MENTAL
0
Feet
Graphic Scale
20 40 60
15°±VT GridMagnetic
PARCEL ID: 1540-00760 SPAN: 600-188-10694
Demolition & EPSC
Plan
C1-02
01/20/2023
1" = 20'
22-523
PJM
CMJ
JAD
Shelburne & Swift
760 & 764 Shelburne Rd. &
31 Swift St.
South Burlington, VT
DEMOLITION NOTE:
ALL ON SITE EXISTING STRUCTURES, SURFACING, ABOVE GROUND UTILITIES AND
BELOW GROUND UTILITIES SHALL BE REMOVED AS SHOWN. NO DEMOLITION
SHALL OCCUR WITHOUT PROPER LOCAL/STATE APPROVALS AND
IMPLEMENTATION OF EROSION CONTROL MEASURES IN ACCORDANCE WITH
APPLICABLE STATE PERMITS AND EROSION CONTROL PLANS. DEMOLITION AND
INFRASTRUCTURE REMOVAL SHALL OCCUR IN A RESPONSIBLE MANNER AND IN
ACCORDANCE WITH PLANS, SPECIFICATIONS, PERMITS, CONSTRUCTION SITE
WASTE REDUCTION PLANS AND OTHER APPLICABLE CODES AND
REQUIREMENTS. MOST ITEMS REQUIRED TO BE REMOVED OR ABANDONED ARE
LABELED ON THIS SHEET. THE CONTRACTOR SHALL STUDY THESE DESIGN PLANS
AND REMOVE OR ABANDON ALL ITEMS NECESSARY TO COMPLETE THE
PROJECT, EVEN IF NOT LABELED ON THIS SHEET. IN SOME CASES ABANDONED
UTILITIES CAN REMAIN AT THE ENGINEER OR OWNER'S DISCRETION.
GAS STATION DEMOLITION NOTE:
ALL DEMOLITION AND REMOVAL OF EXISTING FEATURES
ASSOCIATED WITH THE PRIOR GAS STATION USE SHALL
ADHERE TO VT ENVIRONMENTAL REGULATIONS. THE
CONTRACTOR SHALL COORDINATE WITH THE OWNER
AND ENGINEER REGARDING REQUIRED
ENVIRONMENTAL APPROVALS PRIOR TO DEMOLITION.