Loading...
HomeMy WebLinkAboutZP-23-042 - 0760 Shelburne Road 2/2/2023DDDDDDOHOHOHOHOHOHOHOH OH OH UPUPUPUPUPUPUPUP21 3 214 2 1 6 217213214212211215216214 2 1 2 213 21 1 216217213215212210214213211212210210212211213215217216214208209218219210211213212216214218217210209209210211212208N/F 764 SHELBURNE RD. LLC, C/O GARY BOURNE N/F GARY BOURNE N/F TKHS LLC N/F LEE THERESA M LIVING TRUST, C/O DUFF AND PHELPS N/F GARY J. BOURNE N/F HANDY MOUNTAHA TRUST 1-STORY BUILDING 2300 SQ. FT. GAS CANOPY 1929 SQ. FT. 1-STORY BUILDING 2812 SQ. FT. 1-STORY BUILDING 6157 SQ. FT. 1-STORY BUILDING 1-STORY BUILDING RAMP PAVED DRIVE PAVED DRIVE PAVED DRIVESHELBURNE ROAD (U.S. ROUTE 7)SWIFT STREET SHED D D D D D D D D D D D D D D D D D D D DD WASTE OIL TANK CONCRETE PAD WITH TANK ACCESS WELLS TRANSFORMER ON CONCRETE PAD D D D D D RIM = 209.0 18" RCP iIN(E) = 202.2 18" RCP iIN(S) =201.3 18" RCP IOUT(W) = 200.6 116'±137'±122'±140'±118'±79'±7'±45'±125'±56'± 76'±99'±239'± RIM = 210.8 15" RCP iIN(N) = 204.1 12" RCP iIN(E) =204.3 18" RCP iOUT(W) = 203.9 1-STORY BUILDING APPROX. LOCATION EX. 8" WATER MAIN (TO BE VERIFIED) APPROX. LOCATION EX. 6" WATER MAIN (TO BE VERIFIED) CROSSWALK SIGNAL POLE LEGAL LOAD LIMIT SIGN GAS METER UTILITY COVER SILT FENCE TO TERMINATE AT EDGE OF CONSTRUCTION ENTRANCES SOIL STOCKPILE (TYP.) LOCATION SHOWN FOR ILLUSTRATIVE PURPOSES AND SUBJECT TO CHANGE DURING CONSTRUCTION EXISTING BUILDING, CURBING, & ASSOCIATED STRUCTURE TO BE REMOVED EXISTING BUILDING, CURBING, & ASSOCIATED STRUCTURE TO BE REMOVED EXISTING BUILDING, CURBING, & ASSOCIATED STRUCTURE TO BE REMOVED EXISTING BUILDING, CURBING, & ASSOCIATED STRUCTURE TO BE REMOVED CHAINLINK CONSTRUCTION FENCE AROUND PERIMETER OF SITE AT PROPERTY LINE STABILIZED CONSTRUCTION ENTRANCE 24' WIDE X 30' LONG MINIMUM CONSTRUCTION ENTRANCE (TYP.) SILT FENCE TO BE INSTALLED AROUND PERIMETER OF PROJECT SITE SCESCE SCE CONCRETE FOOTING FOR ROUTE 7 OVERHEAD LANE ASSIGNMENT SIGN RIM = 207.9 SUMP = 203.1 18" RCP iOUT +/- 202.7 TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED ALL OVERHEAD UTILITIES TO BE REMOVED ALL EXISTING TREES AND VEGETATION TO BE REMOVED ALL EXISTING UNDERGROUND UTILITIES TO BE REMOVED GAS STATION SIGN ROAD WORK SIGN RIM = 207.5 CLOGGED RIM = 213.1 12" CMP iOUT(W) = 208.6 TO BE REMOVED Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVILP ROF E SSIONAL E N G INEERLICEN S E DJENNIFER ANN DESA U T E LSSTA TE O F VER M ONTField Book: For Local Permitting Only 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLAN NING ENVIRON MENTAL 0 Feet Graphic Scale 20 40 60 15°±VT GridMagnetic  PARCEL ID: 1540-00760 SPAN: 600-188-10694 Demolition & EPSC Plan C1-02 01/20/2023 1" = 20' 22-523 PJM CMJ JAD   Shelburne & Swift 760 & 764 Shelburne Rd. & 31 Swift St. South Burlington, VT DEMOLITION NOTE: ALL ON SITE EXISTING STRUCTURES, SURFACING, ABOVE GROUND UTILITIES AND BELOW GROUND UTILITIES SHALL BE REMOVED AS SHOWN. NO DEMOLITION SHALL OCCUR WITHOUT PROPER LOCAL/STATE APPROVALS AND IMPLEMENTATION OF EROSION CONTROL MEASURES IN ACCORDANCE WITH APPLICABLE STATE PERMITS AND EROSION CONTROL PLANS. DEMOLITION AND INFRASTRUCTURE REMOVAL SHALL OCCUR IN A RESPONSIBLE MANNER AND IN ACCORDANCE WITH PLANS, SPECIFICATIONS, PERMITS, CONSTRUCTION SITE WASTE REDUCTION PLANS AND OTHER APPLICABLE CODES AND REQUIREMENTS. MOST ITEMS REQUIRED TO BE REMOVED OR ABANDONED ARE LABELED ON THIS SHEET. THE CONTRACTOR SHALL STUDY THESE DESIGN PLANS AND REMOVE OR ABANDON ALL ITEMS NECESSARY TO COMPLETE THE PROJECT, EVEN IF NOT LABELED ON THIS SHEET. IN SOME CASES ABANDONED UTILITIES CAN REMAIN AT THE ENGINEER OR OWNER'S DISCRETION. GAS STATION DEMOLITION NOTE: ALL DEMOLITION AND REMOVAL OF EXISTING FEATURES ASSOCIATED WITH THE PRIOR GAS STATION USE SHALL ADHERE TO VT ENVIRONMENTAL REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER AND ENGINEER REGARDING REQUIRED ENVIRONMENTAL APPROVALS PRIOR TO DEMOLITION.