HomeMy WebLinkAboutAgenda 06_SP-22-020_39 Bowdoin St_Neagley Chase#SP-22-020
CITY OF SOUTH BURLINGTON
DEPARTMENT OF PLANNING AND ZONING
NEAGLEY & CHASE CONSTRCUTION
39 BOWDOIN STREET
SITE PLAN APPLICATION #SP-22-020
FINDINGS OF FACT AND DECISION
Site plan application #SP-22-020 of Neagley & Chase Construction to construct a 12,840 sf contractor or
building trade facility with supporting parking and infrastructure improvements, 39 Bowdoin St.
The Development Review Board held public hearings on; June 21, 2022; October 6, 2022; November 15,
2022; and February 7, 2023. Dave Marshall represented the applicant.
Based on testimony provided at the above-mentioned public hearing and the plans and supporting
materials contained in the document file for this application, the Development Review Board finds,
concludes, and decides the following:
FINDINGS OF FACT
1. This project consists of Site plan application #SP-22-020 of Neagley & Chase Construction to
construct a 12,840 sf contractor or building trade facility with supporting parking and infrastructure
improvements, 39 Bowdoin St.
2. The subject property is located in the Industrial & Open Space Zoning District.
3. The owner of record of the subject property is Neagley & Chase Construction.
4. The application was received on April 26, 2022.
5. The plans submitted consist of the following:
Sheet No. Description Prepared By Last Revised Date
A1.0 Building Elevations Scott & Partners 9/21/2022
A2.0 Building Floor Plans Scott & Partners 11/7/2022
C1.0 Overall Site Plan CEA, Inc. 9/21/2022
C1.1 Existing Conditions Site Plan CEA, Inc. 9/21/2022
C2.0 Proposed Conditions Overall Site Plan CEA, Inc. 9/21/2022
C2.1 Proposed Site Improvements Plan CEA, Inc. 9/21/2022
C2.2 Proposed Conditions Grading &
Draining Plan
CEA, Inc. 11/7/2022
C2.3 Proposed Conditions Utility Plan CEA, Inc. 11/7/2022
C2.4 Proposed Lighting Plan CEA, Inc. 9/21/2022
C3.0 EPSC Plan CEA, Inc. 11/7/2022
C3.1 EPSC Narrative CEA, Inc. 9/21/2022
C3.2 EPSC Narrative & Details CEA, Inc. 9/21/2022
C3.3 EPSC Details CEA, Inc. 9/21/2022
C4.0 Site Details CEA, Inc. 9/21/2022
C4.1 Water and Sewer Details CEA, Inc. 11/7/2022
C4.2 Storm Details CEA, Inc. 9/21/2022
C4.3 Storm Chamber System Details CEA, Inc. 9/21/2022
C4.4 Miscellaneous Details CEA, Inc. 11/7/2022
#SP-22-020
2
C4.5 Miscellaneous Details CEA, Inc. 4/7/2022
C5.0, 5.1,
5.2, 5.3,
5.4, 5.5
Specifications CEA, Inc. 9/21/2022
F1.0 Fire Department Access Plan CEA, Inc. 9/21/2022
HB1.0 Height of Building Calculation CEA, Inc. 11/7/2022
L1.1 Proposed Planting Plan CEA, Inc. 11/30/2022
WS1.0 Parking Lot Green Space Plan CEA, Inc. 4/7/2022
TCE Plat TCE Plat Plan Trudell Consulting
Engineers
8/27/1996
A) ZONING DISTRICT & DIMENSIONAL REQUIREMENTS
The lot is currently undeveloped.
IO Zoning District Required Proposed
Min. Lot Size, non-residential use 3 acres 4 acres
Max. Building Height Flat Roof 40 ft 31.8
Max. Building Coverage 30% 6.6%
Max. Overall Coverage 50% 21%
Max. Front Setback Coverage 30% 11.9 & 29.8%
Min. Front Setback 50 ft 30.6 & 41.5 ft1
Min. Side Setback 35 ft 84 ft
Min. Rear Setback 50 ft N/A
1. The Board grants a waiver to reduce the front yard setback from 50 feet to 30 feet due to site constraints
stemming from the recent re-delineation of the wetland area.
13.06 Airport Approach Cones
All applications for development within the Airport Approach Cones, as shown on the Overlay Districts
Map, involving new or expanded buildings or structures shall provide documentation that either a
Notice to the Federal Aviation Authority (FAA) is not required, or an application for a Determination of
No Hazard has been submitted to the FAA. Where an application for Determination of No Hazard has
been submitted, no zoning permit for construction shall be issued without demonstration of receipt of
an issued Determination.
The property is located entirely within an airport approach cone. The applicant has provided a
Determination of No Hazard to Air Navigation, issued March 7, 2022. The Board finds this criterion met.
10.02G Hinesburg Road-North View Protection Zone
(1) No part of any structure within the Hinesburg Road-North View Protection Zone shall exceed an
elevation of 393.5 feet above mean sea level plus 5.8 feet for each 1000 feet that said part of said
structure is horizontally distant from the Hinesburg Road-North View Protection Zone Base Line
shown on the above referenced Scenic View Protection Overlay District Map.
#SP-22-020
3
The proposed building has a flat roof and is 31.8 feet in height. Given the proposed grade of 348 ft,
the Board finds that the highest point of the proposed structure will be 380 feet above sea level.
This elevation is below the elevation of the baseline, and as such, the Board finds this criterion met.
(2) Landscaping and other vegetation located within the Hinesburg Road-North View Protection Zone
shall be maintained so that it does not exceed an elevation of 393.5 feet above mean sea level plus
5.8 feet for each 1000 feet that said landscaping or vegetation is horizontally distant from the
Hinesburg Road - North View Protection Zone Base Line shown on the above referenced Scenic View
Protection Overlay District Map.
The nearest trees are located approximately 2,500 ft from the baseline, which results in a maximum
allowable tree height of 408 ft. The nearest trees are proposed to be at elevation 344, with a max
height of 50 – 60 ft, or 404 ft. The Board finds this criterion met.
B) SITE PLAN REVIEW STANDARDS
14.06 General Review Standards
A. Relationship of Proposed Structures to the Site.
(1) The site shall be planned to accomplish a desirable transition from structure to site, from structure
to structure, and to provide for adequate planting, safe pedestrian movement, and adequate parking
areas. The DRB shall consider the following:
(a) Street Frontage. Maintain internally-consistent building setbacks and landscaping
along the street.
(b) Building Placement, Orientation. Maintain or establish a consistent orientation to the
street and, where a prevalent pattern exists, shall continue the manner in which the site’s
existing building foundations relate to the site’s topography and grade.
(c) Transition Contrast in Scale. Minimize and mitigate abrupt contrasts in scale between
existing, planned or approved development, and proposed development.
(d) Pedestrian Orientation. Improve and enhance pedestrian connections and walkability
within the area proposed for development.
(e) Solar Gain. Orient their rooflines to maximize solar gain potential, to the extent possible
within the context of the overall standards of these regulations.
The building is proposed to have one loading dock facing east. The loading dock doors will be at
grade with the proposed base of the building, though the ground will be lower. Both the south
and east-facing facades include over a dozen windows and are fronted by landscaping features,
including maple trees and ornamental plantings, including shrubs and perennials. The proposed
entry is located in the southwest corner of the building, on the west façade. The applicant has
integrated the proposed parklet into this area of the building to connect the west side of the
building to the frontage along the south side, and to the street.
Transitions are discussed under 14.06(C) below. Adequacy of planting and pedestrian movement
are discussed elsewhere in this document.
#SP-22-020
4
For the proposed 11,317 sf building, twenty-three (23) parking spaces are provided. The Board
finds parking area to be adequate, and finds this criterion met.
(2) Parking:
(a) Parking shall be located to the rear or sides of buildings. Any side of a building facing a
public street shall be considered a front side of a building for the purposes of this subsection.
This criterion is met.
B. Relationship of Structures and Site to Adjoining Area.
(1) The Development Review Board shall encourage the use of a combination of common
materials and architectural characteristics (e.g., rhythm, color, texture, form or detailing),
landscaping, buffers, screens and visual interruptions to create attractive transitions between
buildings of different architectural styles.
(2) Proposed structures shall be related harmoniously to themselves, the terrain and to
existing buildings and roads in the vicinity that have a visual relationship to the proposed
structures.
(3) To accomplish (1) and (2), the DRB shall consider:
(a) Pattern and Rhythm. Update or maintain or extend the overall pattern of
development defined by the planned or existing street grid, block configurations,
position and orientation of principal buildings, prevalence of attached or detached
building types.
(b) Architectural Features. Respond to recurring or representative architectural
features that define neighborhood character, without adhering to a particular
architectural style.
(c) Privacy. Limit impacts and intrusions to privacy on adjoining properties,
including side and back yard areas through context sensitive design.
The applicant has provided elevations of the proposed building. The building is proposed to be
clad in metal panels. The adjacent sites in Meadowland Business Park have a similar
architectural style, with the exception of the existing Neagley and Chase building which is
partially constructed of brick. The Board finds this criterion to be met.
C. Site Amenity Requirement
(1) Sites are required to include a specific minimum area for appropriate Site Amenities. This
section does not apply to projects within the City Center FBC District (which are governed by Section
8.08).
(2) Applicability. Applications for the following shall be required to provide Site Amenities:
(a) Any non-residential development over 5,000 SF.
(b) Additions or expansions exceeding 5,000 SF for existing non-residential structures.
(c) Any residential development, including conversion of non-residential structures to
residential use.
#SP-22-020
5
The proposed facility exceeds 5,000 sf in size and therefore these standards apply.
(3) The required area shall be:
(a) For Non-Residential development, a minimum of 6% of non-residential building gross
floor area.
(b) For Residential development, determined by number of units as:
(i) For fewer than 10 units, 100 square feet per unit;
(ii) For 10 to 19 units, 85 square feet per unit; or
(iii) For 20 or more units, 60 square feet per unit.
The proposed 11,317 sf building requires a minimum of 680 sf of Site Amenity. The proposed Site
Amenity is a 1,338 sf parklet located near the southwest corner of the building, directly adjacent to
the proposed primary entrance and the existing public sidewalk. The proposed Site Amenity features
four paperbark maples and four metal picnic tables. The Board finds this parklet design to meet the
requirements of Site Amenity design and considers this criterion to be met.
14.07 Specific Review Standards
In all Zoning Districts and the City Center Form Based Codes District, the following standards shall
apply:
A. Environmental Protection Standards. All proposed development shall be subject to the
applicable requirements of Article 12, Environmental Protection Standards.
The property contains a wetland, wetland buffer, and river corridor. The river corridor is
contained entirely within the wetland and wetland buffer. The applicant is proposing minor
grading outside of the wetland buffer and is proposing the installation of a temporary silt fence
around the fill used for this project in order to avoid impacts to the wetland buffer. The
applicant is connecting the proposed project to the existing City sewer line outside of the Class II
wetland buffer. As such, the Board finds this criterion met.
B. Site Design Features. All proposed development shall comply with standards for the
placement of buildings, parking and loading areas, landscaping and screening, open space,
stormwater, lighting, and other applicable standards related to site design pursuant to these
Land Development Regulations.
These standards are contained in Article 13 and are discussed below.
C. Access and Circulation. All proposed development shall comply with site access and
circulation standards of Section 15.A.14.
Much of 15.A.14 pertains to the construction of streets, which are not applicable to this
application. The applicable sections of 15.A.14 follow.
15.A.14 (D) Functional Capacity and Transit Oriented Development. The nearest signalized
intersection or those intersections specified by the DRB shall have an overall level of
service “D” or better, at the peak street hour, including the anticipated impact of the fully
developed proposed PUD or subdivision. In addition, the level of service of each through
movement on the major roadway shall have a level of service of “D” or better at full
buildout.
#SP-22-020
6
The applicant has estimated traffic based on 5,490 sf of Warehousing use (ITE LUC #150)
and 7,710 sf of Specialty Trade Contractor use (ITE LUC #180) and estimates that the project
weekday PM peak hour trip generation will be 16 VTEs per hour. The Board finds no
additional traffic evaluation to be necessary.
15.A.14(E) Access and Circulation. The applicant must demonstrate that the street network
is arranged to meet applicable access management, traffic, and pedestrian circulation
standards under these Regulations, including criteria for site plans under Article 14,
Transect Zone Subdivisions under Article 9, or a type of Planned Unit Development under
Article 15.C; and, for state highways, VTrans Access Management Program Guidelines in
effect at the time of application. Unless otherwise specified under these regulations, the
street network, including the location and arrangement of streets, must be designed to:
(1)-(6) not applicable
(7) Provide for safe access to abutting properties for motorists, cyclists, and
pedestrians, including safe sight distances, access separation distances, and
accommodations for high-accident locations.
The Board finds the pedestrian access to be adequate and supports the proposed
driveway widths.
(8) Align access point with existing intersections or curb cuts and consolidate existing
access points or curb cuts within the subdivision, to the extent physically and
functionally feasible.
At previous hearings, the Board asked the applicant whether the curb cut on Bowdoin St
could be re-configured to align with the existing curb cut on the opposite side of the
street. The applicant reviewed a variety of options and concluded that the request from
the Board to re-align the proposed curb cut in the manner suggested is not functionally
feasible. The Board finds that, although the proposed access on not aligned with the
curb cut across the street, it is not functionally feasible to align the two access points,
and as such, finds this criterion met with respect to the proposed driveway location.
(9) Minimize vehicular access point (curb cuts) to abutting properties and building lots
along pedestrian-oriented street frontage; and provide, where feasible, shared
vehicular access to frontage and other abutting building lots via rear alleys, side
streets, service lanes, shared driveways, or rear cross connections between adjoining
parcels.
The street network in this location is such that Bowdoin Street cannot be extended
much further due to the location of the interstate, and Meadowland Drive cannot be
extended much further due to the location of Muddy Brook and its associated wetland
complex. Because of the wetland to the west, no connection to the west may occur.
The northern property is occupied by the Department of Homeland Security, and as
such no cross lot connection to the north is recommended. The Board finds this
criterion met.
D. Transportation Demand Management (TDM) [reserved]
#SP-22-020
7
E. Building Form. Development within the City Center Form Based Code District, the Urban
Design Overlay District, and other districts with supplemental building form standards shall
adhere to the standards contained therein.
Not applicable.
F. Streetscape Improvements. A proposed new construction or extension/expansion of an
existing structure exceeding the thresholds listed in either (a) Section 14.09(B) or (b) Section
8.11(D) within the City Center Form Based Code, or Section 3.15(D) in all other zoning districts,
shall be required to upgrade adjacent sidewalks, greenbelts, and related street furniture
(trees, benches, etc.) to the standards contained within the applicable Street Type and
Building Envelope Standard. Nothing in this subsection shall be construed to limit
requirements for additional upgrades as necessary to meet the requirements of these
Regulations.
The Board finds Bowdoin Street to be an Industrial Access Road, the cross section for which
includes a 10-ft wide recreation path and street trees. The applicant is proposing street trees.
There is an existing 5-ft bituminous walk on the side of the street facing the subject property.
Given the nature of the street and its limited potential for expansion, the Board finds the
existing facility to be sufficient. The Board finds this criterion met.
F. Access to Abutting Properties. The reservation of land may be required on any lot for
provision of access to abutting properties whenever such access is deemed necessary to reduce
curb cuts onto an arterial or collector street, to provide additional access for emergency or
other purposes, or to improve general access and circulation in the area.
The Board finds no reservation of land to be necessary.
G. Utility Services. Electric, telephone and other wire-served utility lines and service
connections shall be underground insofar as feasible and subject to state public utilities
regulations. Any utility installations remaining above ground shall be located so as to have a
harmonious relation to neighboring properties and to the site. Standards of Section 15.A.18,
Infrastructure, Utilities, and Services, shall also be met.
Wire-served utilities are proposed to be underground.
The Director of Public Works reviewed the originally proposed plan on 6/1/2022 and indicated
there were no comments on this application. The Board finds the approved plans to be less
impactful and therefore to not require additional Public Works review. Any changes necessary
for connection to public infrastructure are anticipated to be of the magnitude allowable as field
changes.
The South Burlington Water Department Director reviewed the plans on May 27, 2022, and
offered several comments, which the applicant has subsequently incorporated.
H. Disposal of Wastes. All dumpsters and other facilities to handle solid waste, including
compliance with any recycling, composting, or other requirements, shall be accessible, secure
and properly screened with opaque fencing to ensure that trash and debris do not escape the
enclosure(s). Small receptacles intended for use by households or the public (ie, non-dumpster,
non-large drum) shall not be required to be fenced or screened.
#SP-22-020
8
The applicant is proposing to screen the dumpster in accordance with the regulations. The Board
finds this criterion met.
C) SUPPLEMENTAL REGULATIONS
13.02 Off Street Parking and Loading
F. Access management Requirements. It is the intent of the City to minimize traffic and
pedestrian conflicts caused by vehicular driveways on public roadways by reducing the
number of required driveways and by minimizing the number of vehicles utilizing such
driveways off public roadways. All applicants must make an effort to reduce these impacts. All
commercial lots (retail, restaurant, office, service uses, excluding residential, agricultural and
industrial uses) located adjacent to other commercial lots must provide a driveway connection
to any adjacent commercial lot. If the adjacent property owner does not want to provide for
that connection, the applicant must provide an easement to do so in the future when
circumstances may change. This driveway connection or easement should be located where
vehicular and pedestrian circulation is most feasible.
As discussed above, The Board finds cross-lot connections to not be viable. However, in the case
of a site plan, the Board only has the authority to waive dimensional requirements. The
applicant has provided a draft deed for a 25-foot-wide access easement between the subject
property and the property to the north. The Board finds the applicant shall record the access
easement, subject to review and approval by the City Attorney, prior to issuance of a zoning
permit.
G. Design requirements for Parking Spaces, Parking Aisles, Lighting and Landscaping
(1) Design requirements for off-street parking and loading are provided in Table 13-2
and Figure 13-1, Section 13.04, Landscaping , Screening, and Street Trees, and Section
13.07, Exterior Lighting. All paved parking spaces shall be striped or otherwise
physically delimited.
Dimensional requirements are met.
Parking lot landscaping and lighting are further discussed below.
(2) The location of parking areas and loading docks shall prevent conflicts with
entering and existing traffic onto a public street and prevent conflicts between
vehicles and pedestrians. The distance between access points and parking areas shall
be adequate to minimize blockage and prevent back-ups onto the public street.
As noted above, the location of the loading dock requires trucks to reverse in Bowdoin
Street. The Board finds that, as a low-traffic dead-end road in an industrial zoning
district, the truck movements necessitated by the proposed driveway configuration will
not lead to an inordinate amount of blockage or back-ups on the public street.
(3) Provision shall be made for access by police, fire and emergency vehicles.
The Fire Chief reviewed the plans on June 1, 2022 and provided several comments,
which the applicant subsequently incorporated to the satisfaction of the Fire Chief. As
such, the Board finds this criterion met.
#SP-22-020
9
(4) Pedestrian safety. Insofar as practicable, pedestrian and bicycle circulation shall be
separated from motor vehicle circulation. Safe and convenient pedestrian circulation,
including appropriate sidewalks, shall be provided on the site and its approaches. The
pedestrian circulation on site shall be designed to minimize adverse effects of
vehicular traffic on sidewalks and recreation paths.
The Board finds appropriate pedestrian accommodations have been provided.
(5) Bicycle parking or storage facility. See Section 13.03
(6) Stormwater management strategies that facilitate infiltration including but not
limited to recessed planting islands, bioretention facilities, and pervious parking
spaces are encouraged in the design of any off-street parking or loading area.
Stormwater management is discussed under 13.05 below.
13.03 Bicycle Parking and Storage.
The applicant has provided two bicycle racks, providing short-term parking spaces for four bicycles, and
a bicycle storage space & locker.
Required Bike Parking Required
Short Term (1 per 5k sf office, 1
per 20k sf contractor facility,
minimum 4)
4
Long Term (50% of short term
retail and office, 1 per unit)
2
Clothes Lockers 1
The proposed short-term and long-term bicycle parking spaces meet both the minimum number of
bicycle parking spaces required and the design standards for these spaces. As such, the Board finds this
criterion met.
13.04 Landscaping, Screening & Street Trees
B. Except for parking spaces accessory to a one-family or two-family dwelling, all off-street
parking areas subject to review by the Development Review Board, shall be curbed and landscaped
with appropriate trees, shrubs, and other plants including ground covers, as approved by the
Development Review Board. Sections of recessed curb are permitted if their purpose is to allow
stormwater runoff from the adjacent parking area to reach stormwater collection, treatment and
management infrastructure. The Development Review Board shall consider the adequacy of the
proposed landscaping to assure the establishment of a safe, convenient, and attractive parking area
and the privacy and comfort of abutting properties.
(1) All off-street parking areas shall be landscaped around the perimeter of the lot with trees,
shrubs and other plants. Perimeter planting shall be set back from the curb sufficiently to allow for
snow storage. The purpose of perimeter planting shall be to mitigate the view of the parking lot
from the public way and from adjacent uses and properties, and to provide shade and canopy for
the parking lot. In some situations it may be necessary both for surveillance purposes and for the
#SP-22-020
10
perception of safety to install the size and type of plants that leave visual access between the
parking lot to the public way or other pedestrian areas.
Parking areas are proposed to be curbed. Trees are proposed around the perimeter of the parking
areas.
(2) In all parking areas containing twenty-eight (28) or more contiguous parking spaces
and/or in parking lots with more than a single circulation lane, at least ten percent (10%) of the
interior of the parking lot shall be landscaped islands planted with trees, shrubs and other plants.
Such requirement shall not apply to structured parking or below-ground parking.
The proposed parking area includes only twenty-three (23) parking spaces. As such, this criterion is
not applicable.
(3) All interior and perimeter planting shall be protected by curbing unless specifically designed as
a collection and treatment area for management of stormwater runoff as per 13.04(B)(5)(c)
below. Interior planted islands shall have a minimum dimension of six (6) feet on any one side, and
shall have a minimum square footage of sixty (60) square feet. Large islands are encouraged.
Curbing is provided. The Board finds this criterion met.
(3) Landscaping Requirements
The City Arborist reviewed the plans on 12/12/2022 and provided the following
comments:
Tree and Shrub Planting Details should be included in the plans, otherwise the plans
look fine.
The Board finds that the applicant must comply with the comments of the City Arborist
as a condition of approval.
(a) Landscaping shall include a variety of trees, shrubs, grasses and ground covers. All
planting shall be species hardy for the region and, if located in areas receiving road runoff or
salt spray, shall be salt-tolerant.
The Board finds this criterion met.
(b) At least one (1) major deciduous shade tree shall be provided within or near the
perimeter of each parking area, for every five (5) parking spaces. The trees shall be placed
evenly throughout the parking lot to provide shade and reduce glare. Trees shall be placed a
minimum of thirty (30) feet apart.
23 parking spaces are provided, requiring 5 shade trees. 6 shade trees are provided and are
located on both sides of the parking area. The Board finds this criterion met.
(c) Trees shall have a caliper equal to or greater than two and one-half (2 ½) inches when
measured on the tree stem, six (6) inches above the root ball.
This criterion is met.
(c) Where more than ten (10) trees are installed, a mix of species is encouraged; the
species should be grouped or located in a manner that reinforces the design and layout of the
parking lot and the site.
#SP-22-020
11
The applicant is proposing to install sixteen trees representing six different species. As such, the
Board finds this criterion met.
(e) Within the City Center FBC District, landscaping required within this section shall not
count towards meeting minimum landscape budget requirements as detailed in Section
13.04(G).
This criterion is not applicable.
(7) Snow storage areas must be specified and located in an area that minimizes the potential for
erosion and contaminated runoff into any adjacent or nearby surface waters.
Snow storage areas are specified. The Board finds this criterion met.
C. Screening or buffering. The Development Review Board will require landscaping, fencing, land
shaping and/or screening along property boundaries (lot lines) whenever it determines that a) two
adjacent sites are dissimilar and should be screened or buffered from each other, or b) a property’s
appearance should be improved, which property is covered excessively with pavement or structures or
is otherwise insufficiently landscaped, or c) a commercial, industrial, and multi-family use abuts a
residential district or institutional use, or (d) a parking or loading area is adjacent to or visible from a
public street.
The Board finds the project to be similar to adjacent uses and as such this criterion to be not applicable.
D. Front Yards of Non-Residential and Multi-Family Uses. In the case of non-residential and multi-
family uses, the required front yard and/or the frontage along designated arterial and collector
streets (see Article 3, Section 3.06 for this list) shall be suitably landscaped and maintained in good
appearance. Landscape elements that reduce stormwater runoff and promote stormwater infiltration
are encouraged. The Development Review Board shall require the applicant to meet the provisions of
sections 13.04(F) and (G).
The applicant is proposing a suitable amount of landscaping in the front yards, including a conveyance
swale. As such, The Board finds this criterion met.
G(3) Landscaping Budget Requirements. The Development Review Board shall require minimum
planting costs for all site plans, as shown in Table 13-4 below. In evaluating landscaping requirements,
some credit may be granted for existing trees or for site improvements other than tree planting as
long as the objectives of this section are not reduced. The costs below are cumulative; for example, a
landscaping budget shall be required to show a planned expenditure of three percent of the first
$250,000 in construction or improvement cost plus two percent of the next $250,000 in construction or
improvement cost, plus one percent of the remaining cost over $500,000. The landscaping budget shall
be prepared by a landscape architect or professional landscape designer.
The estimated construction cost for this project is $1,750,000. As such, the minimum required landscape
budget for this project is $25,000. The applicant is proposing to install $25,310 worth of landscaping
features, including a variety of trees, shrubs, and perennials. The perennials proposed include a mix of
grasses, vines, and flowers, and are intended to serve as both pollinator habitat and as a primary
component of the site amenity landscaping. The Board finds the proposed landscape budget to be
acceptable and considers this criterion met.
13.05 Stormwater Management
#SP-22-020
12
Stormwater standards apply when one-half acre or more of impervious surface exists or is proposed to
exist, and where 5,000 sf of impervious is created or reconstructed.
1. The City Stormwater Section will review these plans prior to the scheduled DRB hearing on Tuesday,
February 7th, and Staff will provide an update including those comments at that time.
13.07 Exterior Lighting
Lighting requirements are summarized as follows.
(1) Fixtures must be downcast and shielded
(2) Illumination must be evenly distributed
(3) Fixtures must be placed to minimize lighting from becoming a nuisance
(4) Poles shall be rustproof metal, cast iron, fiberglass, finished wood or similar structural
material, with a decorative surface or finish
(5) Poles & building mounted fixtures may be no higher than 30-ft
(6) Poles must be located in safe locations
Specific requirements for maximum illumination levels are included in Appendix A and are limited to 3-
foot candles average at ground level. The applicant has provided a photometric drawing indicating this
criterion is met. Only the lighting fixtures indicated in this photometric drawing and on the site plan are
permitted. The Board finds this criterion met.
13.08 Outdoor Storage and Display
The applicant is proposing to use a 705 sf screened area accessible as outdoor storage
A. Outdoor Storage. Outdoor storage of goods, materials, vehicles for other than daily use, and
equipment shall be subject to the following provisions:
(1) Any outdoor storage shall be appurtenant to the primary use of the property and shall be allowed
only in nonresidential districts and upon approval of the DRB in conjunction with a site plan,
conditional use and/or PUD application.
The Board finds this criterion met.
(2) The Development Review Board may require that outdoor storage areas in connection with
commercial or industrial uses be enclosed and/or screened where the storage area may comprise
an attractive nuisance, where the proposed use of the storage areas present opportunities for theft,
or where the Board finds that said storage areas are in view of residentially-zoned parcels.
The applicant is proposing to enclose the area with a 6-foot to 7-foot chain link fence with plastic slats.
The Board finds this criterion met.
3.18 Energy Standards
All new buildings are subject to the Stretch Energy Code pursuant to Section 3.18: Residential and
Commercial Building Energy Standards of the LDRs. This now includes provision of a solar-ready roof.
The applicant is including PV-enabling power accommodations as part of this application. As such, the
Board finds this criterion met.
#SP-22-020
13
DECISION
Motion by xxx, seconded by xxx, to approve Site Plan application #SP-22-020 of Neagley & Chase
Construction, subject to the following conditions:
1. All previous approvals and stipulations shall remain in full effect except as amended herein.
2. This project shall be completed as shown on the plan submitted by the applicant and on file in the
South Burlington Department of Planning and Zoning as conditioned herein.
3. A digital PDF version of the approved final plan set must be delivered to the Administrative Officer
before issuance of a zoning permit.
4. The applicant shall record an access easement, subject to review and approval by the City Attorney,
prior to issuance of a zoning permit.
5. The plans must be revised to show the changes below and shall require approval of the
Administrative Officer prior to issuance of a zoning permit:
a. The inclusion of a ‘Tree & Shrub Planting Details’ sheet in the provided plan set.
6. Prior to issuance of a zoning permit, the applicant must post a landscaping surety for $17,500 in
plantings in accordance with the methodology in LDR 15.15B. This bond shall remain in full effect for
three (3) years to assure that the landscaping has taken root and has a good chance of survival.
7. The applicant must regularly maintain all stormwater treatment and conveyance infrastructure.
8. All exterior lighting must be installed or shielded in such a manner as to conceal light sources and
reflector surfaces from view beyond the perimeter of the area to be illuminated. Only the lighting
fixtures indicated in the approved photometric drawings and on the record site plans are permitted
to be installed.
9. The applicant must obtain a zoning permit within six (6) months from the date of this decision or
this approval expires and is null and void. The applicant may submit a request for an extension to
obtain a zoning permit under the terms outlined in Section 17.04 of the LDRs, but the request must
be submitted prior to the expiration of this approval.
10. The applicant must continue to maintain the approved landscaping in a vigorous growing condition
throughout the duration of the use.
11. Pursuant to Section 15.13(E) of the Land Development Regulations, any new utility lines, services,
and service modifications must be underground.
12. The proposed project must adhere to standards for erosion control as set forth in Section 16.03 of
the South Burlington Land Development Regulations. In addition, the grading plan must meet the
standards set forth in Section 16.04 of the South Burlington Land Development Regulations.
13. The applicant must obtain a Certificate of Occupancy from the Administrative Officer prior to use of
the proposed expansion.
14. Any change to the site plan shall require approval by the South Burlington Development Review
Board or the Administrative Officer as allowed by the Land Development Regulations.
15. Bicycle racks must meet the minimum requirements of 13.14 and Appendix G.
#SP-22-020
14
Dan Albrecht Yea Nay Abstain Not Present
Mark Behr Yea Nay Abstain Not Present
Frank Kochman Yea Nay Abstain Not Present
Quinn Mann Yea Nay Abstain Not Present
Dawn Philibert Yea Nay Abstain Not Present
Stephanie Wyman Yea Nay Abstain Not Present
John Stern Yea Nay Abstain Not Present
Motion carried by a vote of X – X – X.
Signed this ____ day of February 2023, by
_____________________________________
Dawn Philibert, Chair
Please note: An appeal of this decision may be taken by filing, within 30 days of the date of this
decision, a notice of appeal and the required fee by certified mail to the Superior Court, Environmental
Division. See V.R.E.C.P. 5(b). A copy of the notice of appeal must also be mailed to the City of South
Burlington Planning and Zoning Department at 575 Dorset Street, South Burlington, VT 05403. See
V.R.E.C.P. 5(b) (4)(A). Please contact the Environmental Division at 802-828-1660 or
http://vermontjudiciary.org/GTC/environmental/default.aspx for more information on filing
requirements, deadlines, fees and mailing address.
The applicant or permittee retains the obligation to identify, apply for, and obtain relevant state
permits for this project. Call 802.477.2241 to speak with the regional Permit Specialist.
D REXISTING
HOUSE
EXISTING
GARAGE
390
388
386390
390
390
396397
399 393
392391390
391
391
391395395
391
393394
389387388
389
386
385
387
385 384 MEA
D
O
W
L
A
N
D
D
R
I
V
EFM
388
384
395
394
393
392
393
396
392
398
391
394
394 395
395
390
391
392
393394395396397
356
355
35
0 360347
346346 357356
359347348350351
353352 355
34334
7
348
34
9 351358359355
356355356357354
352354
354
353349347346.4346355355
353
354
353
358352
354
35
8
346
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
D
D
D
D
D
D
D
D
D
D
D D
D
D
D
D
n/f
GRANDVIEW
FARM, LLC
n/f
GPT
PROPERTIES
TRUST
n/f
CHASE PROPERTIES
n/f
NEAGLEY & CHASE
CONSTRUCTION
n/f
NORTHEAST
TERRITORIES, INC.
n/f
GREENFIELD
CAPITOL, LLC
n/f
MEADOWLANDS
BUSINESS COMPLEX
CONDOMINIUMS, LLC
n/f
GREENFIELD
CAPITOL, LLC
n/f
SBRC PROPERTIES,
LLC
n/f
BURLINGTON
PROPERTIES LIMITED
PARTNERSHIP
n/f
THE ROCK OF
GREATER
BURLINGTON INC.
n/f
SUPERTEMP
REALTY, LLC
n/f
BURLINGTON
PROPERTIES LIMITED
PARTNERSHIP
1" = 150'C1.0
OVERALL
SITE PLAN
1.UTILITIES SHOWN DO NOT PURPORT TO CONSTITUTE OR REPRESENT ALL UTILITIES LOCATED UPON OR ADJACENT TO THE SURVEYED
PREMISES. EXISTING UTILITY LOCATIONS ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL FIELD VERIFY ALL UTILITY CONFLICTS. ALL
DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER. THE CONTRACTOR SHALL CONTACT DIG SAFE (888-344-7233) PRIOR TO ANY
CONSTRUCTION.
2.ALL EXISTING UTILITIES NOT INCORPORATED INTO THE FINAL DESIGN SHALL BE REMOVED OR ABANDONED AS INDICATED ON THE PLANS
OR DIRECTED BY THE ENGINEER.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS (WITH TIES) FOR ALL UNDERGROUND UTILITIES. THOSE PLANS SHALL BE SUBMITTED
TO THE OWNER AT THE COMPLETION OF THE PROJECT.
4.THE CONTRACTOR SHALL REPAIR/RESTORE ALL DISTURBED AREAS (ON OR OFF THE SITE) AS A DIRECT OR INDIRECT RESULT OF THE
CONSTRUCTION.
5.ALL GRASSED AREAS SHALL BE MAINTAINED UNTIL FULL VEGETATION IS ESTABLISHED.
6.MAINTAIN ALL TREES OUTSIDE OF CONSTRUCTION LIMITS.
7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK NECESSARY FOR COMPLETE AND OPERABLE FACILITIES AND UTILITIES.
8.THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL ITEMS AND MATERIALS INCORPORATED INTO THE SITE WORK. WORK SHALL
NOT BEGIN ON ANY ITEM UNTIL SHOP DRAWING APPROVAL IS GRANTED.
9.IN ADDITION TO THE REQUIREMENTS SET IN THESE PLANS AND SPECIFICATIONS, THE CONTRACTOR SHALL COMPLETE THE WORK IN
ACCORDANCE WITH ALL PERMIT CONDITIONS AND ANY LOCAL PUBLIC WORKS STANDARDS.
10.THE TOLERANCE FOR FINISH GRADES FOR ALL PAVEMENT, WALKWAYS AND LAWN AREAS SHALL BE 0.1 FEET.
11.ANY DEWATERING NECESSARY FOR THE COMPLETION OF THE SITEWORK SHALL BE CONSIDERED AS PART OF THE CONTRACT AND SHALL
BE THE CONTRACTOR'S RESPONSIBILITY.
12.THE CONTRACTOR SHALL COORDINATE ALL WORK WITHIN TOWN ROAD R.O.W. WITH TOWN AUTHORITIES.
13.THE CONTRACTOR SHALL INSTALL THE ELECTRICAL, CABLE AND TELEPHONE SERVICES IN ACCORDANCE WITH THE UTILITY COMPANIES
REQUIREMENTS.
14.EXISTING PAVEMENT AND TREE STUMPS TO BE REMOVED SHALL BE DISPOSED OF AT AN APPROVED OFF-SITE LOCATION. ALL PAVEMENT
CUTS SHALL BE MADE WITH A PAVEMENT SAW.
15.IF THERE ARE ANY CONFLICTS OR INCONSISTENCIES WITH THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE
ENGINEER FOR VERIFICATION BEFORE WORK CONTINUES ON THE ITEM IN QUESTION.
16.PROPERTY LINE INFORMATION IS APPROXIMATE AND BASED ON EXISTING TAX MAP INFORMATION. THIS PLAN IS NOT A BOUNDARY SURVEY
AND IS NOT INTENDED TO BE USED AS ONE.
17.IF THE BUILDING IS TO BE SPRINKLERED, BACKFLOW PREVENTION SHALL BE PROVIDED IN ACCORDANCE WITH AWWA M14. THE SITE
CONTRACTOR SHALL CONSTRUCT THE WATER LINE TO TWO FEET ABOVE THE FINISHED FLOOR. SEE MECHANICAL PLANS FOR RISER
DETAIL.
18.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING TESTING AND INSPECTION SERVICES INDICATED IN THE CONTRACT DOCUMENTS,
TYPICAL FOR CONCRETE AND SOIL TESTING.
19.THE CONTRACTOR IS RESPONSIBLE FOR ALL LAYOUT AND FIELD ENGINEERING REQUIRED FOR COMPLETION OF THE PROJECT. CIVIL
ENGINEERING ASSOCIATES WILL PROVIDE AN AUTOCAD FILE WHERE APPLICABLE.
20.THE OWNER SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ANY AND ALL SAFETY FENCES OR RAILS ABOVE EXISTING AND PROPOSED
WALLS. THE OWNER SHALL VERIFY LOCAL, STATE AND INSURANCE REQUIREMENT GUIDELINES FOR THE INSTALLATION AND VERIFY ANY
AND ALL PERMITTING REQUIREMENTS.
GENERAL NOTES
PROJECT
LOCATION
DSM
DSM
SAL
19145
APR. 7, 2022
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
NORTHEAST
TERRITORIES, INC.
20 SOUTH CREST
BURLINGTON, VERMONT
LOT 7
MEADOWLAND
BUSINESS PARK
SOUTH BURLINGTON VERMONT
NEAGLEY & CHASE
CONSTRUCTION
66 BOWDOIN ST., STE. 100
SOUTH BURLINGTON, VERMONT
LOCATION MAP
1" = 2000'
PROJECT
LOCATION
116
89HINESBURG ROADME
A
D
O
W
L
A
N
D
D
R
MEADOWLAND DR.BOWDOIN ST.THOMPSON ST.RAN
D
ALL
ST.
KNOLL CIR.
NEAGLEY & CHASE
OFFICE BUILDING
9/21/22 DSM REVISED SITE LAYOUT
P:\AutoCADD Projects\2019\19145\1-CADD Files-\dwg\19145 - Site.dwg, 9/21/2022 1:44:47 PM
SSSSSSSS
S
S S
S
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ST
ST
ST
ST
ST
ST
ST
STEEESSSSSETCETCETCETC
ETCST
SETCETCETCETCETCETCSTG
G
GGGGGGGG WWWWWWW
W
W
W
W
W
W
W
W
WWWWWW
W
EX. HYDRANT
W
W
W
ST
STW
8" D.I.W36' OF 8" D.I. WATER SERVICE
W/ CAP & THRUST BLOCK
SSSSSSWWWWWWWWW
W
W
W
W W W
ST
ST
ST
S
S
S
S
D
D
G G15" HDPE
15" HDPE EXISTING STORM WATER PONDS
S
S
S
S
S
EX. CB
RIM 341.3
INV. 338.6 (4" E)
INV. 336.9 (18"
N)
EX.
UTILITY
CABINET
(TYP.)
18" HDPE w/
F.E.S.
INV. 335.8
18" HDPE
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
EX. CB
RIM 347.7
EX. CB
RIM 347.7
18" HDPE
EX. 8" WATER
SERVICE
INV. UNKNOWN
APPROX. LOCATION
8" PVC SEWER SERV.
INV. UNKNOWN 8" D.I. WATER MAIN10" D.I. WATER MAIN
76'X3'X6' CONCRETE BOX CULVERT8" PVC
8" PVC
8" PVC
EX. SMH
RIM 346.3
INV. 335.5 (CL)
EX. SMH
RIM 340.3
INV. 332.6 (CL)
SEWER SERV.18" HDPEBOWDOIN ST.MEADOWLAND DR.THOMPSON ST.APPROXIMATE LIMITS
OF SOIL STOCKPILE
50' SETBACK 50' SETBACK35' SETBACK
351350350350349349348348348348347347347347346346
34634534
5 345344
3443
4
4
344343
3433
4
3
343
342
3423
4
2
342
341
341341341
340
340
339
339
338
338
337
337336SIGNSPRING?WET
8" OAK
8" OAK8" OAK
8" MAPLE
8" MAPLE
8" MAPLE
(2) WATER DIG SAFE
MARKINGS
4" SPRUCE
2" SPRUCE
2" SPRUCE
4" SPRUCE
(3) 4" SPRUCE
(2) 4" SPRUCE
4" SPRUCE
4" SPRUCE
(3) 4" SPRUCE
4" SPRUCE
2" SPRUCE
2" SPRUCE
CMF
FLUCH
58" CRF
FLUCH
58" CRF
FLUSH(4) 6" FIR
2" FIR
EX. CB
RIM 341.4
INV. 339.3
(4" E)
INV. 336.3
(18" E)
INV. 336.3
(18" S)
INV. 336.2
(18" NW)340338339349345
346
339 341
4" LINDEN
4" LINDEN
4" LINDEN
4" LINDEN
4" LINDEN
2" SPRUCE
710.87'
715.19'230.22'230.51'LOT 7
3.96 AC.
TREE REMOVAL (TYP.)8" D.I.2" LOCUST
DSM
DSM
SAL
1" = 30'
19145
C1.1
EXISTING
CONDITIONS SITE
PLAN
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
NORTHEAST
TERRITORIES, INC.
20 SOUTH CREST
BURLINGTON, VERMONT
LOT 7
MEADOWLAND
BUSINESS PARK
SOUTH BURLINGTON VERMONT
NEAGLEY & CHASE
CONSTRUCTION
66 BOWDOIN ST., STE. 100
SOUTH BURLINGTON, VERMONT
LOCATION MAP
1" = 2000'
PROJECT
LOCATION
89
116
NEAGLEY & CHASE
OFFICE BUILDING
APR. 7, 2022
6/27/22 DSM REVISED WETLAND DELINEATION
P:\AutoCADD Projects\2019\19145\1-CADD Files-\dwg\19145 - Site.dwg, 9/21/2022 12:24:54 PM
SSSSSSSS
S
S
S
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ST
ST
ST
ST
ST
ST
ST
STEEESSSSSETCETCETCETC
ETCS
T
SS
ETCETCETCETCETCETCETCSTSTETC
G
G
GGGGGGGG WWWWWWW
W
W
W
W
W
W
W
W
WWWWWWW
W
W
W
STST
STSTWW
350
350
350
350
35
0
35
0
34
0
340340
340
STST SSSSSSWWWWWWWWWWW
W
W
W
W
W W W
ST
ST
ST
ST
E
UTS S
S
S
S
S
D
G GGS
S
S
S
S
S
G
G
G
G
G
G
G
G
G
G
G
G
G
G
GBOWDOIN ST.MEADOWLAND DR.THOMPSON ST.50' SETBACK 50' SETBACK35' SETBACK
PROPOSED BUILDING
11,317 SF
F.F.E. 348.0
351350350350349349348348348348347347347347346346
34634534
5 345344
3443
4
4
344343
3433
4
3
343
342
3423
4
2
342
341
341341341
340
340
339
339
338
338
337
337336340338339349345
346
339 341
710.87'
715.19'230.22'230.51'LOT 7
3.96 AC.
D
D
D
D
DSM
DSM
SAL
1" = 30'
19145
C2.0
PROPOSED
CONDITIONS
OVERALL SITE
PLAN
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
NORTHEAST
TERRITORIES, INC.
20 SOUTH CREST
BURLINGTON, VERMONT
LOT 7
MEADOWLAND
BUSINESS PARK
SOUTH BURLINGTON VERMONT
NEAGLEY & CHASE
CONSTRUCTION
66 BOWDOIN ST., STE. 100
SOUTH BURLINGTON, VERMONT
LOCATION MAP
1" = 2000'
PROJECT
LOCATION
116
89
NEAGLEY & CHASE
OFFICE BUILDING
APR. 7, 2022
6/8/22 DSM REVISED PER CITY COMMENTS
9/21/22 DSM REVISED SITE LAYOUT
P:\AutoCADD Projects\2019\19145\1-CADD Files-\dwg\19145 - Site.dwg, 9/21/2022 1:43:12 PM
SSSSSSSS S
S
S
S
S
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ETC
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
STST
S
T
SETCETCETCETCETCETCETCETCS
T
STST
WWWWWWWWWWW
W
W
W
W
W
W
W
W
W
W
W
W
W
WWWWWW
W
W
W
W
S
D
G
G
G
G
G
G
G
G
G
G
G
G
G
G
GBOWDOIN ST.MEADOWLAND DR.
5
PROPOSED BUILDING
11,317 SF
F.F.E. 348.0
PROPOSED
SWALE
50'
W
E
T
L
A
N
D
B
U
F
F
E
R
EXISTING BIT. CONC. SHA
R
E
D
U
S
E
P
A
T
H EXISTING 5' BIT. CONC. SIDEWALK
30.7' SETBACK
(WAIVER OF 19.3')
40.1' SETBACK
(WAIVER OF 9.9')
10" CONC.
RETAINING
WALL
DUMPSTER
ENCLOSURE
351350350350349349348348348348347347347347346346
34634534
5 345344
3443
4
4
344343
3433
4
3
343
342
3423
4
2
342
341
341341341
340
340
339
339
338
338
337
337T T340338339
349345
346
339 341
2' TAPERED CURB
6' TAPERED CURB
2' TAPERED
CURB
30'20'
FIRE DEPT.
CONNECTION 346345RT348348349347347348349349347LOT 7
3.96 AC.
PROPOSED OUTDOOR STORAGE AREA - 6-7'
HIGH CHAIN LINK FENCING WITH PLASTIC
SLAT INSERTS AND DOUBLE GATE
612
BIKE RACK
ACCESSIBLE
PARKING
SIGN
6' TAPERED
CURB
6' TAPERED
CURB (TYP.)22'9'(TYP.)18' (TYP.)
60'60'NEW SEGMENTAL RETAINING WALL
2
0
'348347346345
346
347346
345
34
5
346
347
346
346
343
345
3463455' CONCRETE
SIDEWALK (TYP.)100.3'SNOW
STORAGE
SNOW
STORAGE
SNOW
STORAGE
BOLLARD
BOLLARD
347
PATIO
DSM
DSM
SAL
1" = 20'
19145
C2.1
PROPOSED SITE
IMPROVEMENTS
PLAN
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
NORTHEAST
TERRITORIES, INC.
20 SOUTH CREST
BURLINGTON, VERMONT
LOT 7
MEADOWLAND
BUSINESS PARK
SOUTH BURLINGTON, VERMONT
NEAGLEY & CHASE
CONSTRUCTION
66 BOWDOIN ST., STE. 100
SOUTH BURLINGTON, VERMONT
LOCATION MAP
1" = 2000'
PROJECT
LOCATION
116
89
NEAGLEY & CHASE
OFFICE BUILDING
APR. 7, 2022
6/8/22 DSM REVISED PER CITY COMMENTS
9/21/22 DSM REVISED SITE LAYOUT
30% (MAX.)FRONT YARD COVERAGE
ZONING DISTRICT: INDUSTRIAL OPEN SPACE DISTRICT
DIMENSIONAL SUMMARY
-
3.0 AC.
REQ'D.
LOT FRONTAGE
LOT AREA
PROPOSED
3.96 AC.
BUILD. COVERAGE
LOT COVERAGE
30% (MAX.)
50% (MAX.)
100.3'
FRONT SETBACK
SIDE SETBACK
50'
35'
35'REAR SETBACK N/A
17.6%
6.6%
MEADOWLAND DRIVE 715'
BOWDOIN STREET 253'
MEADOWLAND DRIVE 11.9%
BOWDOIN STREET 29.8%
THOMPSON STREET 230'
MEADOWLAND DRIVE 30.7'
BOWDOIN STREET 40.1'
THOMPSON STREET 545.5'P:\AutoCADD Projects\2019\19145\1-CADD Files-\dwg\19145 - Site.dwg, 9/21/2022 1:46:35 PM
STST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
S
T
ST
S
T
STST
S
S
D
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
PROPOSED BUILDING
11,317 SF
F.F.E. 348.0
351350350350349349348348348348347347347347346346
34634534
5 345344
3443
4
4
344343
3433
4
3
343
342
3423
4
2
342
341
341341341
340
340
339
339
338
338
337
337336T T340338339
349345
346
339 341 346345RT348348349347347348349349347LOT 7
3.96 AC.
D
D
D
ST
D
STETC
ETC
ST 348347346345
346
347346
345
34
5
346
347
346
346
343
345
346345 TEMPORARY CONSTRUCTION
ENTRANCE OR SWEEP STREET
ON DAILY BASIS
INLET PROTECTION
(TYP. OF 5 PLACES)
PREVENT CONSTRUCTION
FLOWS FROM ENTERING
THE INFILTRATION SYSTEM
DURING CONSTRUCTION
TEMPORARY TREE
PROTECTION (TYP.)
TEMPORARY CONSTRUCTION
ENTRANCE OR SWEEP STREET
ON DAILY BASIS
PLACE 4" TOPSOIL. SEED,
FERTILIZE AND EROSION
CONTROL MATTING ON ALL
DISTURBED SURFACES (TYP.)
INSTALL STONE CHECK
DAMS AT 100' INTERVAL
ORANGE CONSTRUCTION
LIMITS TAPE (TYP.)
ORANGE CONSTRUCTION
LIMITS TAPE (TYP.)
PLACE 4" TOPSOIL. SEED,
FERTILIZE AND EROSION
CONTROL MATTING ON ALL
DISTURBED SURFACES (TYP.)
INSTALL SILT FENCE
WITH J-HOOKS (TYP.)
INSTALL SILT FENCE
WITH J-HOOKS (TYP.)
347
GSDSM
DSM
SAL
1" = 20'
19145
C3.0
EPSC PLAN
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
NORTHEAST
TERRITORIES, INC.
20 SOUTH CREST
BURLINGTON, VERMONT
LOT 7
MEADOWLAND
BUSINESS PARK
SOUTH BURLINGTON, VERMONT
NEAGLEY & CHASE
CONSTRUCTION
66 BOWDOIN ST., STE. 100
SOUTH BURLINGTON, VERMONT
LOCATION MAP
1" = 2000'
PROJECT
LOCATION
116
89
NEAGLEY & CHASE
OFFICE BUILDING
APR. 7, 2022
6/8/22 DSM REVISED PER CITY COMMENTS
9/21/22 DSM REVISED SITE LAYOUT
11/7/22 DSM REVISED SEWER SERVICE